Sports Kerala Foundation Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Sports Kerala Foundation - SKF Tender

Works
Civil And Construction
Eprocure
Opening Date11 Sep 2024
Closing Date1 Oct 2024
Tender Amount₹ 71,84,475 
Notes
Download

Costs

Summary

One Panchayath One Playground -development Of Thrikkaruva Mini Stadium At Thrikkaruva Grama Panchayath, Kollam Lac - Retender

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

286

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

12.24

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

6.12

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

122.4

-

-

... More
50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.

62.5

-

-

... More
od370250/2023_2024 : Providing and laying of interlock concrete block pavements having thickness 60mm (M30) as per drawings and technical specification clause 1504 confirming to IS 15658 and laid in required colour and pattern over and including 50mm thick compacted bed of 6 mm metal including edge concreting for 300mm width and 150mm depth with CC M35( @ 0.045 m3/m)

231.71

-

-

... More
od370273/2023_2024 : Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of 6mm aggregate etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.) (Based on CPWD 16.84)

479.7

-

-

... More
100.98.1008 : Engaging Coolie

7

-

-

... More
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)

4.54

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

196.65

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

860.25

-

-

... More
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

1056.9

-

-

... More
24.2 : Providing and fixing double scaffolding system (Cup lock type ) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube chakkus, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The evaluational area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.

30

-

-

... More
13.99.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work

1012.11

-

-

... More
Ground Developments Works

-

-

-

... More
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil

2348.1

-

-

... More
od286881/2023_2024 : SKF_OD 7/2022-2023 Supplying and stacking for measurement sieved red earth at site including royalty and carriage upto 5 k.m. lead,all labour charges for stacking, loading and unloading etc complete.( Based on CPWD 30.2.2 & 30.2.4.3)

730.52

-

-

... More
od331638/2023_2024 : SKF_OD 4/2022-2023 Supplying and stacking for measurement Sieved Jamuna Sand at site including cost of sand and carriage upto 5 k.m. lead all labour charges for stacking, loading and unloading etc complete.( Based on CPWD 30.2.2 & 30.2.4.3)

182.63

-

-

... More
od331657/2023_2024 : SKF - OD 3/2022-2023 Mixing earth and jamuna sand in the required proportion specified or directed by the officer - in- charge including all cost of labour charges, hire charges of machineries etc. complete.(Based on CPWD 30.2.9)

913.15

-

-

... More
od331658/2023_2024 : SKF - OD 4/2022-2023 Spreading of earth and jamuna sand in the required thickness as per direction of officer - in- charge including all cost of labour charges, hire charges of machineries etc. complete.(cost of earth and jamuna sand to be paid separately).(Based on CPWD 30.2.8)

913.15

-

-

... More
od331659/2023_2024 : SKF - OD 5/2022-2023 Consolidation of subgrade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc.including all cost of labour charges, hire charges of machineries,fuel,oil etc. complete.(Based on CPWD 16.1)

10436

-

-

... More
od286850/2023_2024 : Supply and Installation of Fixed type 7's Football Goal Post (3.65m x 1.80m x 1.20m) made of pipe 10cm dia G.I. pipe with nylon net as per the direction of Engineer in Charge.

1

-

-

... More
od305434/2023_2024 : BADMINTON POST : Supply and installation of heavy duty badminton post in aluminium and steel uprights option with built in weights and floor protection pads. Base,uprights and back supports can be detached. Rate also includes wheels for easy movement, steel uprights (comes in a pair), badminton net etc. Approval shall be taken prior to supply of item.

1

-

-

... More
Drainage

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

161.4

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

16.14

-

-

... More
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

64.65

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

125.96

-

-

... More
od331773/2023_2024 : Lifting, conveying and placing the newly casted RCC slabs of any thickness on the base of pool above aggregate layer in position including all labour charges and miscellaneous expenses etc complete (Based on MoRTH 55.25 )

13.82

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

579.6

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

4202.06

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

0.3

-

-

... More
Fencing

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1.52

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1.82

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

2.7

-

-

... More
od286862/2023_2024 : Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete(Rate based on CPWD 50.10.2)

1191.69

-

-

... More
od286863/2023_2024 : Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all charges as per the direction of Engineer in charge.(rate based on DAR 26.81)

276

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

40.21

-

-

... More
Inauguration Stone and Name Board

-

-

-

... More
od332075/2023_2024 : Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre polished, machine cut for inauguration granite stone of required size, approved shade, colour and texture laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) joint treated with white cement, mixed with matching pigment, epoxy touchups including rubbing, curing etc. complete at all levels. Area of slab over 0.50 sqm (Based on Item 8.2.2.2 of DSR)

1

-

-

... More
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

77.16

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

60

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

12.4

-

-

... More
13.71 : Lettering with black Japan pint of approved brand and manufacture

400

-

-

... More
16.21 : Engraving letters in hard stone

500

-

-

... More
Ground Flood light Electrification works

-

-

-

... More
od332218/2023_2024 : Supply and Installation of 16mtr fixed type Stadium mast suitable for mounting minimum 12no of luminaires, made of Hot-dip Galvanization process as per IS 4759:1996 with monkey climbing arrangement and maintenance platform for easy maintenance and aiming of luminaires with lightening spike. The pole shaft shall be made of 4mm thickness in 2 sections, base dia not less than 250mm and the base plate shall be of min 20mm thick. with all accessories and luminary carriage suitable to install 10/12 nos luminaries in symmetrical arrangement equivalent including RCC foundation with fixed bolts as required and lighting spikes approved by engineer in-charge.

4

-

-

... More
od332219/2023_2024 : SKFOD_ Supply Conveyance, installation, testing and commissioning of 400W (+/-10w) rating LED Floodlight luminaire with minimum 48000 Lumens Light output in CRI>70. Graphite grey powder coated pressure die-cast aluminum LED housing designed to act as heat sink for efficient dissipation of heat.Heat resistant toughened glass provided with silicon gasket to ensure ingress protection. LEDs are provided with secondary Polycarbonate lens optics to get optimum optical performance and available in at least 2 optics options of WB and MB a to achieve required lux level mounted on each LED. Luminaire should have Minimum IP 66 and IK 08 Protection. Internal Surge protection of 4KV and External surge protection of 10 KV in minimum required. The LED's used in the luminaire shall be shall be high power with power consumption between 1W to 5W with CRI greater than 70 in 5700K CCT. The luminaire shall be designed to ensure lumen depreciation L70 over 50000 burninghours as per LM 80 report. The luminaire should have fins on the back to ensure good heat dissipation and to prevent dirt from settling on the luminaire along with aiming angle scale. Driver should be fully potted BIS certified of same Luminaire brand and shall have a power factor >0.95 and THD less than 10% Make: Bajaj, Phillips, Crompton or Approved by Engineer in charge

40

-

-

... More
od332220/2023_2024 : SKFOD ODP - Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type, totally enclosed, IP 65, pedestal mounted, free standing with top canopy, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply fabricated using 2mm thick CRCA sheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) including following switchgears accessories for the LT Panel. The work shall be completed with all other accessories as per approved SLD INCOMER 63 A/40A, FP,25kA MCCB - 1 No.63 Amp TPN bus bars ;INSTRUMENTS; Surge protection device -Type 1+2 Voltage protection level should not be less than 1.5 kV , ;4A, C curve SP MCB - 3 Nos, RYB indication lamp OUTGOINGS 6A to32 A, 'C' Curve SP MCB - 32 Nos (arranged by 4X8).

1

-

-

... More
od332221/2023_2024 : SKFOD_ Supply, installation, testing and commissioning of Outdoor Type Floor Mounting KSEB metering panel, suitable for accommodating 3 Phase Energy meter and consisting of 3 nos. of 40 A cutout with HRC fuse( or as per KSEB) , neutral link in separate chamber, inter connections and separate cabin shall be provided in outdoor panel to accommodate VDB/DB as per the requirement etc. as required, and including necessary supports of floor or wall mounting as required, and the panel fabricated out of 14 SWG CRCA sheet with lockable door with sealing facility having glass window for energy meter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories.

1

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od332222/2023_2024 : SKFOD_ Supply and fixing SINTEX Box (150mmx150mmx100mm) or nearest size including MCB Rail or Connectors for giving connections including all accessories complete as required

1

-

-

... More
90.14.10.4 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.

1

-

-

... More
od332223/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40 A to 63A TP MCB, C-CURVE

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

28

-

-

... More
2.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural

4

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

3

-

-

... More
90.12.5.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 10 sq mm

376

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp

9

-

-

... More
90.12.5.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 16 sq mm

40

-

-

... More
90.12.5.38 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm

194

-

-

... More
90.12.5.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. .3 core 6 sqmm

15

-

-

... More
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50/38 mm or nearest size

185

-

-

... More
90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 63/50 mm or nearest size

200

-

-

... More
90.6.5.13 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 4.00 sq mm

268

-

-

... More
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 1.50 sq mm

32

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

64

-

-

... More
90.12.5.28 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm

20

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

7

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

6

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

2

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG)

72

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

90

-

-

... More
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

400

-

-

... More
5.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

30

-

-

... More
od332224/2023_2024 : SKF_OD - Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, with providing masonry enclosure with cover plate / FRP Earth Pit Chamber. ( but without charcoal/ coke and salt ) etc as required.<br>

6

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

8

-

-

... More
90.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

2

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

4

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

12

-

-

... More
od332259/2023_2024 : SKFOD_ Supply and fixing SINTEX Box (150mmx150mmx100mm) or nearest size including MCB Rail or Connectors for giving connections including all accessories complete as required

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.