Sports Kerala Foundation Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Sports Kerala Foundation - SKF Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Mar 2024
Closing Date25 Mar 2024
Tender Amount₹ 25,94,388
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Summary
Renovation And Upgradation To The Administrative Building At G.v. Raja Sports School Mylom, Thiruvananthapuram- Electrification Works-retender
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SKF_667687_2Bid Award Id
ViewTender No
249/SKF/CE/2023-24Tender Authority
Sports Kerala Foundation ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
190
-
-
... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
185
-
-
... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
50
-
-
... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
42
-
-
... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
6
-
-
... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
8
-
-
... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
20
-
-
... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2
-
-
... More
1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
2
-
-
... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
2
-
-
... More
1.28.6 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
2
-
-
... More
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
2
-
-
... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
3
-
-
... More
1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
2
-
-
... More
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
3
-
-
... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block
including connection etc as required.
50
-
-
... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
60
-
-
... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
5
-
-
... More
od250585/2023_2024 : SKFOD6W_Supply,Installation, testing and commissioning of pre-wired, 6W Surface/recess mounting round LED down light fittings complete with all accessories directly on ceiling/ wall, including connection with PVC insulated, copper conductor, single core cable and earthing etc. as required.
5
-
-
... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
10
-
-
... More
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
20
-
-
... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
100
-
-
... More
od250420/2023_2024 : Supply and fixing of following 4 pole 63amps. (415 Volts),100mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
1
-
-
... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
17
-
-
... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C
39
-
-
... More
od39111/2023_2024 : Servicing of 400mm wall mounted fan including disconnecting the pull switch nylon cord and re-installation of wall fan without speed control as instructed in Engineer-in charge
15
-
-
... More
od39112/2023_2024 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.
10
-
-
... More
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.
10
-
-
... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5
-
-
... More
od250308/2023_2024 : SKFDSROD: Supply and installation of pre-wired 20W LED batten fitting complete with all accessories and tube etc directly on ceiling/wall, including connection with PVC insulated,copper conductor single core cable and earthing etc as required.<br>(Make: Phillips, Crompton greaves, Bajaj, Lucker or Approved by engineering in charge)
114
-
-
... More
90.15.4.6 : Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
2
-
-
... More
od250302/2023_2024 : SKF-OD Supply,Installation, testing and commissioning of pre-wired, 9W Surface mounting round LED down light fittings complete with all accessories directly on ceiling/ wall, including connection with PVC insulated, copper conductor, single core cable and earthing etc. as required
10
-
-
... More
od250303/2023_2024 : SKFOD15W_Supply, Installation, testing and commissioning of pre-wired, 15W recess mounting round LED down light fitting complete with all accessories directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.<br>Make : Phillips, Crompton Greaves, Bajaj, Lucker or approved by engineer in charge
50
-
-
... More
od250307/2023_2024 : Supply and fixing of LED strip light fixture of 5Watts/ 5mtr including all accessories like drive etc having provision to connect with 1.5 sqmm wires as required
70
-
-
... More
1.59 : Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
117
-
-
... More
od252277/2023_2024 : Supply, installation, testing and commissioning of Inverter type ceiling-mounted four-way cassette type Split AC unit complete with the indoor unit and outdoor units. Indoor unit with DX cooling coil, filter, fan-motor<br>assembly and inbuilt drain pump. Air-cooled condensing unit complete with Scroll/Rotary and compressor condenser fans condenser coil. The unit should operate on R22/R410A/R32<br>refrigerant Rates shall include cordless remote controller Make Bluestar/Carrer/LG/Equivalent" 2.0TR Cassette unit<br>
2
-
-
... More
od252353/2023_2024 : Supply and Laying of the copper pipe for the 4ton Cassette AC units including the insulated sleeves with all accessories as required
25
-
-
... More
Lightning Protection
-
-
-
... More
od39103/2023_2024 : Supply and installation vertical run - Round wires - , 8 mm / 50 mm², AlMgSi, semi-rigid Round wire according to DIN EN 62561-2 (VDE 0185 Part 202) for use as air-termination system or down conductor in lightning protection systems.Diameter Ø conductor: 8 mm Cross-section: 50 mm2 Material: AlMgSi Materi. with Conductor holder for Metal Roof with all accessories
150
-
-
... More
od39174/2023_2024 : Supply and Installation for sub panel Rewired complete unit consisting of a base part and plug-in protection modules ,High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps ,High reliability due to "Thermo Dynamic Control" SPD monitoring device.SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II Nominal voltage (a.c.) (UN) 230 / 400 V (50 / 60 Hz) Max. continuous operating voltage (a.c.) [L-N] (UC) 320 V (50 / 60 Hz) Max. continuous operating voltage (a.c.) [N-PE] (UC) 255 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (In) 20 kA Max. discharge current (8/20 µs) (Imax) 40 kA Lightning impulse current (10/350 µs) [N-PE] (Iimp) 12 kA with all accessories
10
-
-
... More
od39175/2023_2024 : Supply and Installation - For 3 phase power supply system Prewired combined lightning current and surge arrester, energy-coordinated with power supply systems for cell sites ,Encapsulated spark gap technology with a width of only 1 module / pole allows compact and space-saving design for easy installation within the power supply cabinets/SPD according to EN 61643-11 / ... IEC 61643-11 type 1 + type 2 / class I + class II Energy coordination with terminal equipment (≤ 10 m) type 1 + type 2 + type 3 Nominal voltage (a.c.) (UN) 230 / 400 V (50 / 60 Hz) Max. continuous operating voltage (a.c.)[L-N]/[N-PE] (UC) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L-N]/[N-PE] (Iimp) 25 / 100 kA Specific energy [L-N]/[N-PE] (W/R) 156.25 kJ/ohms / 2.50 MJ/ohms Nominal discharge current (8/20µs) (In) 25 / 100 kA.
12
-
-
... More
od39104/2023_2024 : Supply of HORIZONTAL RUN - Round wires wire, 8 mm / 50 mm², AlMgSi, semi-rigid Round wire according to DIN EN 62561-2 (VDE 0185 Part 202) for useas air-termination system or down conductor in lightning protection systems.Diameter Ø conductor: 8 mm Cross-section: 50 mm2 Material: AlMgSi Material with Conductor holder for Metal Roof with all accessories
420
-
-
... More
od39105/2023_2024 : Supply and Installation of Universal connector For cross-connections, T connections and parallel connections Material of clamp: StSt Clamping range Rd: 8-10 mm Screw: M10 x 35 mm Standard: EN 62561-1 with all accessories
358
-
-
... More
od39106/2023_2024 : Supply and installation of Earthing: C-Bar 3/4''; dia, UL listed, 3000 mm long + 22.6 Kg GC+ and clamp for termination with all accessories
10
-
-
... More
od39107/2023_2024 : Providing and fixing of test joint with enclosure suitable for 10mm dia copper bonded solid steel round conductor with 100 microns of copper bonding (if pure copper conductor 25x3 mm solid tape also can be used) and 8mm dia solid round aluminum conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced poly carbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.
10
-
-
... More
od39108/2023_2024 : Supply, Installation, Testing & Commissioning of Early Streamer Emission<br>(ESE) type lightning Air terminal.Supporting Mast The mounting pole used to support the lightning air terminal shall be minimum length of 05 Mtr. , non corrosive and made up of medium class GI / SS pipe of 1.5′′ diameter having base plate at bottom for securely fixing the mast on roof top. The mounting pole and supports shall be securely fixed with the<br>brackets and PVC insulated metallic guy wires to withstand the maximum wind velocity ofthat area.Protection Radius :- TYpe II Make :- ABB / STROMKING / POWER TRAC/AXIS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.
3
-
-
... More
od39109/2023_2024 : Supply, Installation, Testing & Commissioning of non-electronic & non-<br>resettable (Not require any external power supply) type lightning strike Digital counter to count the lightning stroke having display with IP-67 enclosure including all accessories and connection..(Digital 2 Digits) Make :- ABB / STROMKING / POWER TRAC/AXIS All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge.
3
-
-
... More
90.15.4.11 : Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
7
-
-
... More
Conventional Fire Alarm System
-
-
-
... More
od39197/2023_2024 : Supply, installation, testing, and commissioning of Addressable/Conventional type Multi-Detector (photoelectric cum rate of rising temperature type) complete with all accessories like base. base box, etc. to be installed under/above the false ceiling, roof, and concealed space, etc. interconnecting to loop cable complete as required. Shall be UL listed and FM Approved, complete as required as per the technical specification.
12
-
-
... More
od39198/2023_2024 : Supply, installation, testing and commissioning of conventional type wall sounder cum strobe for both audio and visual indication complete with all fixing<br>accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be EN/UL/FM/LPCB approved/listed.
12
-
-
... More
od39199/2023_2024 : Supplying, installation, testing & commissioning of conventional type beam<br>detector with addressable module complete with emitter and receiver including all fixing accessories etc complete as required. The product must be UL listed,<br>complete in all respect as per technical specification.
2
-
-
... More
od39200/2023_2024 : Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.
12
-
-
... More
od39203/2023_2024 : Supply, installation, testing, and commissioning of Manual Call Point with break glass, hammer, and chain, complete as per Tech. Spec. Make:Win Fire /Ravel or equivalent
12
-
-
... More
od39204/2023_2024 : Supply, installing, testing and commissioning of Micro Processor Based Conventional Type Fire Alarm Panel, 4-Zone Capacity, with visual LED indications for fire/fault alarms, signals and should have stage alarm facility with maintenance-free battery back up for 8 hours normal operation and 30 minutes alarm operation.8-Zone approved make Powder Coated Cabin, with zone/ all zone selection facility, all call facility, The panel shall be fabricated by M.S. sheet and powder coated both inside & outside, the door shall be the glass-fronted type with locking arrangement, as per specification. Make:ASE Fire/ Secure Agni or equivalent
1
-
-
... More
od39276/2023_2024 : Supply and laying of 2x 1.5sq.mm armored Copper FRLS cable ISI marked with proper clamping, supports, and terminations appropriately above ground as per technical specification
180
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements