Sports Kerala Foundation Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Sports Kerala Foundation - SKF Tender
Security and Emergency Services
Eprocure
Opening Date11 Mar 2022
Closing Date21 Mar 2022
Tender Amount₹ 5,42,031
Costs
EMD
₹ 13,600Document Cost
₹ 1,298Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_SKF_481448_1Bid Award Id
ViewTender No
27/SKF/CE/2021-22Tender Authority
Sports Kerala Foundation ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
750
-
-
od342139/2021_2022 : Supply and laying of Outdoor CAT 6 UTP OSP Cable<br>A HDPE compound insulates the cores with anIEC 60332-1 complied LS0H inner jacket and UV resistant heavy duty FR PVC Black outer sheath. The rugged construction of this cable makes it ideal for outdoor installations, Category 6 compliant n LS0H inner sheath and FR PVC outer n UV resistant n Suitable for outdoor Installations. ANSI/TIA/EIA-568-C.2, ISO/IEC 11801, IEC 6074-1(Toxicity), IEC 6074-2 (Acid Gas) standards<br>Approved Makes- Commscope or Equivalent
205
-
-
od342140/2021_2022 : Supply and laying of 12 Core – 9/125 Micron Single Mode Outdoor Fiber Cable OS2<br>Type of Cable : OS2 Single mode , Optical Properties Attenuation at 1310 nm ≤ 0.34 dB/KM at 1550nm ≤ 0.22 dB/KM , Maximum Tensile Strength Short term : 1000N , Maximum Crush resistance Short term : 2000N/10CM , Operating Temperature : -10° C to + 70°C , Sheath : UV Stabilized HDPE , Over all CableDiameter : 9.5 mm- 10 mm , Fiber Tube Identification : Single Tube , No. Of Elements : 1, Fiber Protection(Tubes) : Polybutyleneterephthalate(PBT), PeripheralStrengthMember : TwoSteelWires , Mass(Nominal) : 95 Kg/Km , CoreWrapping : PolyethyleneTerephthalate , InnerSheath : Polyethylene , Armouring : Copolymer Steel tape Armor , Sheath : HD Polyethylene (UV Stabilized) , Water Blocking : Thixotropic Gel , ROHS Complaint, ISO/IEC 11801 : 2002 -2nd Edition, Type OS1, ITU-T REC G 652D spec for Low Water Peak fiber, TIA 568, EIA 455, AS/ACIF S008; AS/NZS 3080 , Max. Bending Radius (during installation) : 20D , Max. Bending Radius (during full load) : 10D , Life of Cable: The minimum expected life of the cable is not less than 25 years.<br>Approved Makes- Commscope or Equivalent
110
-
-
od342142/2021_2022 : Supply and installation of CAT6 UTP 2meter Patch chord<br>4 pair 24 AWG stranded copper wire , Pre-terminated with WE8W plugs , Slim clear anti-snag slip on boots , Suitable for EIA 568A or 568B wiring , LS0H sheath , RoHS Compliant , Conductor size: 24 AWG stranded copper wire Nom. O.D.: 5.9mm Sheath: LS0H Bend radius: 4X O.D. Operating temperature range: -20°C to 60°C. Plug MIN operating life: 750 insertion cycles RJ45 plug and boot material: Clear polycarbonate, Contact material: 0.35mm thick copper alloy Contact plating: Selective gold RJ45 plug dimensions compliant with: ISO/IEC 60603-7-4 and FCC 47 Part 68, Max voltage: 150 VAC (max) Max current: 1.5A @ 25°C, ISO/IEC 11801:2002/Amd 2:2010 Cat 6-, TIA-568-C.2 Cat 6 , ETL Verified , LS0H Sheath: CSA FT1, IEC 60332-1, IEC 61034, support data networks for 10/100BASE-T and 1000BASE-T applications.<br>Approved Makes- Commscope or Equivalent
25
-
-
od342143/2021_2022 : Supply and installation of CAT6 UTP 1meter Patch chord<br>4 pair 24 AWG stranded copper wire , Pre-terminated with WE8W plugs , Slim clear anti-snag slip on boots , Suitable for EIA 568A or 568B wiring , LS0H sheath , RoHS Compliant , Conductor size: 24 AWG stranded copper wire Nom. O.D.: 5.9mm Sheath: LS0H Bend radius: 4X O.D. Operating temperature range: -20°C to 60°C. Plug MIN operating life: 750 insertion cycles RJ45 plug and boot material: Clear polycarbonate, Contact material: 0.35mm thick copper alloy Contact plating: Selective gold RJ45 plug dimensions compliant with: ISO/IEC 60603-7-4 and FCC 47 Part 68, Max voltage: 150 VAC (max) Max current: 1.5A @ 25°C, ISO/IEC 11801:2002/Amd 2:2010 Cat 6-, TIA-568-C.2 Cat 6 , ETL Verified , LS0H Sheath: CSA FT1, IEC 60332-1, IEC 61034, support data networks for 10/100BASE-T and 1000BASE-T applications.<br>Approved Makes- Commscope or Equivalent
25
-
-
od342144/2021_2022 : Supply and installation of OFC single mode 1 meter SC – SC duplex Patch chord<br>100% Factory Tested – Guaranteed performance, LSOH Jacket Standard – Reduces toxic/corrosive, Sheath : LSZH, ROHS Compliant , ISO/IEC 11801, ANSI/TIA/EIA 568.C.3-2000, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-596 , Cordage O.D.: 2.0mm +/- 0.1mm x 4.1 +/- 0.2mm , Buffer Diameter: 900Um , Primary Coating : 245um , Suitable for use inside with Sliding and fixed patch panels , Support 24 Fusion splice protectors in 45mm or 61mm lengths , Base and Self-adhesive pads for securing on a flat surface and a lid, Material – ABS (Halogen Free) , Support Multimode and Single mode, Dimensions: 47mm x 99mm x 12mm ( WxLxH) , Max. Attenuation @ 850nm: 3.5 dB/Km, Max. Attenuation @ 1300nm : 1.5 dB/Km<br> Approved Makes- Commscope or Equivalent
12
-
-
od342145/2021_2022 : Supply and installation of CAT 6 Information outlet<br>Contact Material : Copper Alloy, Contact Plating : 50 Micron Gold/100 micron Nickel , Dust Cover :To avoid dust. contaminants and to prevent incompletely plugged patch cord, Spring Loaded Shutter inside the information outlet. IDV V shaped , Plastic Housing :Polycarbonate UL94V-0 Rated , Termination Cap: Has to be provided at rear of the Information Outlet. Compatibility : Should be compatible with 24 port patch panel,RJ 11 & RJ 12 , Operating. Cycle : Minimum 750 Insertion Cycles , Standards : ETL Verified for CAT 6 Compliance , ISO 11801 Class E Compliant , EIA/TIA 568.C.2-Componnet Complaint , RJ 11 & RJ 12 Compatible , Wire Accommodation : 22-24 AWG , UL Listed , ROHS complaint<br> Approved Makes- Commscope or Equivalent
25
-
-
od342146/2021_2022 : Supply and installation of Single shutter faceplate<br>Single shutter faceplate with SMB Box in recess/on surface and making good the damages, colour washing etc as requiredType : British Style Standard Face Plate , Dimensions : 86 mm X 86 mm , Material : VE10ABS , Compatible For UTP & STP , Labelling Facility( Data voice, Fax, Video) , ROHS Complaint <br>Approved Makes- Commscope or Equivalent
25
-
-
Electrical works
-
-
-
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
120
-
-
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
60
-
-
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
250
-
-
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
400
-
-
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
110
-
-
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
10
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
10
-
-
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
10
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
10
-
-
90.10.3.22 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 6A 3 pin plug top
2
-
-
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
5
-
-
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
5
-
-
90.12.9.2 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 50/38 mm or nearest size
60
-
-
90.9.1.1 : Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 50 X 50 MM cable management system with base and lid
30
-
-
90.9.2.1 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 100 x 50 mm CMS with base and lid
60
-
-
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with
inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing
the same in ground as required.
5
-
-
od342138/2021_2022 : Supply, conveyance, erection and commissioning of 5 meter camera pole (4 Meter above and 1 Meter below ground) manufactured using stainless steel as per BS EN 10025 grade S355 J0 or equivalent. The pole shall be hot dip galvanised (single dip) internally and externally having uniform coating thickness of 85/65 microns for bottom/top sections respectively as per IS 2629/BSEN ISO 1461. The pole shall be in two sections with top section having diameter 90 mm, bottom section having diameter 130 mm and thickness 3 mm. Both the sections should be welded together or joined by telescopic slip joint giving a continuous tapered profile and presenting good visual appearance. The pole section should be suitable for wind velocity as per IS 875 Part-3. The pole should consist of suitable single arm bracket of suitable length welded to it for mounting the camera and the bottom of the pole foundation should have provision for fixing CCTV cabinet box (255 x 355 x 122 mm) in recess to incorporate all other accessories as required.
2
-
-
90.12.39.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
60
-
-
90.12.41.2 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
15
-
-
od342141/2021_2022 : Supply and installation of Single phase 1kVA UPS 72V Pure Sinewave with inbuilt battery for the back of the one hour with THD of output voltage greater 5% of the linear load and IP protection with all accessories
1
-
-
90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.5 sq mm
25
-
-
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
1
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
8
-
-
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG)
25
-
-
Civil works
-
-
-
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
0.25
-
-
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.03
-
-
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
0.35
-
-
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
20
-
-
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
0.25
-
-
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
0.25
-
-