Smart City Thiruvananthapuram Limited Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Smart City Thiruvananthapuram Limited Tender
Eprocure
Opening Date25 Aug 2023
Closing Date7 Sep 2023
Tender Amount₹ 1,74,44,174
Costs
EMD
₹ 50,000Document Cost
₹ 6,505Tender Fee
Refer Documents
Summary
Selection Of Contractor For Execution Of Electrical Fire And Hvac Works At Iccc Building
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_SCTLT_598529_1Bid Award Id
ViewTender No
SCTL/TECH/3839/2023/AME/RFP/04Tender Authority
Smart City Thiruvananthapuram Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp
70
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 95 sq mm
150
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 185 sq mm
35
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp
95
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp
15
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 25 sq mm with factory made clamp
130
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 35 sq mm with factory made clamp
110
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 70 sq mm
110
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 35 sq. mm (32mm)
4
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 95 sq. mm
4
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 185 sq. mm (57mm)
8
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
6
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
2
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)
6
-
-
... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 4 X 35 sq. mm
4
-
-
... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed I XLPE copper conductor cable of 1.1 kV grade as required. 4 X 70 sq. mm
4
-
-
... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
250
-
-
... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip
200
-
-
... More
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run). 25 x 3 mm copper strip
50
-
-
... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG)
40
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)
2
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)
8
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)
75
-
-
... More
Supply and installation of 4ft LED linear battern should have specially designed extruded aluminium housing , lumen output greater than 1900 lm and maximum system wattage of 20W including separate CC APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 10%, power factor 0.9, system efficacy of lamp greater than 90 lumen/watt and including all necessary accessories as required complete.
12
-
-
... More
Supply and installation of 2ft LED linear battern should have specially designed polcarbonate housing , lumen output greater than 950 lm and maximum system wattage of 10W including separate CC APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 10%, power factor 0.9, system efficacy of lamp greater than 95 lumen/watt and including all necessary accessories as required complete.
6
-
-
... More
Supply and installation of pendent mounted high efficient LED downlighter, with housing made up of diecast aluminium and white powder coated finish, HET diffuser for better light transmission, CRI80, LED efficacy100lm/W,Color temperature-5700K, IP20, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency80%, THD10%, Powerfactor0.9, Surge protection in CM-2KV, Multistage Isolated Constant Current- Constant Voltage Operated driver with range 150-270V AC , Wattage ≤ 15W, system lumen output should be1500 LED shoul bin as per ANSI Bin C78.377A standard. LM80,LM79 and photo biological tast of the luminaire should be produced.
4
-
-
... More
Supply and installation of LED Recessed Mounted downlighter should have Constructed in die cast aluminum Powder Coated White housing and maximum system wattage of 6W with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 4000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 10%, power factor 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
30
-
-
... More
Supply and installation of LED Recessed Mounted downlighter should have Constructed in die cast aluminum Powder Coated White housing and lumen output greater than 1600 lumen with maximum system wattage of 18W with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 10%, power factor 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
30
-
-
... More
Supply of Led Recessed mounted 600*600 mm Luminaire having light output not less than 3600 Lumens with System efficacy 110 Lumen/Watt . Luminaire Housing Shall be made from single piece CRCA body without
welding to avoid rusting and Prismatic diffuser to reduce glare. The Luminaire should be having minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM5 and Co-related color temperature (CCT) of 6500K.The
luminaire must have 4KV surge protection integrated in driver,Ripple5%,UGR19, PF≥0.95, Total harmonic distortion THD≤10%,EMI/EMC Compliant and Operating voltage range 140-270V with High voltage cutoff@325 ± 15V with Auto restart feature. Luminaire and driver
shall be separately BIS approved of same make equivalent to Philips RC380B LED 36S W60L60 PSU PD OC/ kesslec /Osram. LM80,LM79 or equivalent ,Type Test certificate and Bis certificate need to be submitted for approvals.
50
-
-
... More
Supply and installation of LED Recessed Mounted downlighter should have Constructed in die cast aluminum Powder Coated White housing and Lumen output greater than 800 lumen with maximum system wattage of 9W with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 20%, power factor 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
30
-
-
... More
Supply and installation of LED recess Mounted downlighter should have white powder coated pressure die cast aluminium housing and PMMA LGP diffuser , lumen output greater than 350 lm and maximum system wattage of 6W including separate CC,CV APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 20%, power factor 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete
15
-
-
... More
Supply and installation of LED Track Light with aluminium die cast construction with white powder coating clear galss diffuser of 1 mm thick high efficiency reflector optics should be suitable for integral track adaptor with special track locking system to ensure proper mounting on track. lumen output greater than 2000 lm and maximum system wattage of 20W including separate CC, APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 4000 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 10%, power factor 0.9, system efficacy of lamp greater than 85 lumen/watt and including all necessary accessories as required complete.
5
-
-
... More
Supply and installation of LED suspended downlighter should have white powder coated pressure die cast aluminium housing and bottom frame , lumen output greater than 1000 lm and maximum system wattage of 10W including separate CC,CV APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 4000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 10%, power factor 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
2
-
-
... More
Supply and Installation of LED Recessed Mounted IP65 or higher Step light Constructed in die cast aluminum Powder Coated housing with poly carbonate clear diffucsr and maximum system wattage of 7W . LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 3000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD 20%, power factor 0.9, system efficacy of lamp greater than 50 lumen/watt and including all necessary accessories as required complete
4
-
-
... More
Supply and installation of IP65 rated LED Bulkhead fitting with aluminium diecast housing with powder coated ,Polycarbonate opal diffuser,High quality silicon gasket for IP65 Protection,Ambient temp-0 to 45 DegC,LED with 50000 burning hours as per L70 Criteria, CRI70, color temperature- 5700K, , Complete assembly with LED, Driver and accessories pre wired up to terminal block Driver With efficiency85%, THD10%, Power factor0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard. 10W LED Bulkhead luminaire delivering 720lm.
10
-
-
... More
Supply, Installation , testing and commissioning of 10W LED integral Updownlight light with not less than 670 lumens and CCT of 3000k CRI80, IP65 with aluminium housing with anthracite color suitable for aesthetics with PF 0.9 & longer life. Similar to Philips make "31450 Propulsio" or equivalent in approved make list
18
-
-
... More
Supply installation testing and commissioning of Compact substation having 11 / 0.433kV, 250 KVA CRT Dry type, three phase, 50Hz, Dyn11,outdoor type, copper wound transformer with off circuit tappings from +5% to -10% in steps of 2.5%, changeable on off circuit by tap links provided, 3 Nos CTs, 1 No PT, 1no TOD Meter and output connected to 11KV seal off bushings to the transformer as per IS2026- factory assembled, factory tested ready to install and connections type Compact substation complete with an outdoor enclosure having 11 KV VCB at HT side, CRT dry type distribution transformer and Low Voltage Switchgear according to requirement; complete with HT cable interconnection done in between transformer and VCB and suitable sized busbar between transformer and LV incoming main switchgear-MCCB (having isolation duty) of suitable rating according to full load output current of the transformer, all as a single transport unit. The CSS must be compatible with mode bus communication protocol for Building management system and necessary statutatory approvals from Electrical Inspectrate.
1
-
-
... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support,front operated type tested panel board made out of 2 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3 mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.The cable entry should be Top/Bottom entry type according to the site condition.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IEC 61439-1&2 / IS 8623 – 1 standards. The panel must be compatible with Mode bus communication protocol for BMS. Similar to Siemens SIEPAN 8PULV or equivalent in approved makelist.INCOMER: 400A,35KA, 4P MCCB with E/F - 2nos,400A 4P CONTACTOR- 2 no,AMF relay with interlock- 1 no,51G relay- 1 no, OUTGOINGS:125A ,25KA, TP, MCCB - 3 nos,200A , 25KA, TP, MCCB - 3 nos,315A ,25KA,TP,MCCB - 1 nos
1
-
-
... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support,front operated panel board made out of 2mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.The cable entry shall be Top entry type.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall be of form 4 type separation.The board shall confirm IS 8623 standards.The panel must be compatible with Mode bus communication protocol for BMS. INCOMER: 100A TPN Isolator - 1 no, OUTGOINGS: 63A ,25KA,TP MCCB - 4 nos, 40A ,25KA,TP MCCB - 1 no
1
-
-
... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support,front operated panel board made out of 2 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3 mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.The cable entry shall be of Top entry type.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall be of form 4 type separation.The board shall confirm IS 8623 standards.The panel must be compatible with mode bus communication protocol for BMS.INCOMER:125A TPN Isolator - 1 no, OUTGOINGS: 63A ,10KA,4P MCB - 4 nos, 40A ,10KA,4P MCB - 2 nos,32A ,10KA,4P MCB - 1 no
1
-
-
... More
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support ,front operated panel board made out of 2 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3 mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required. The cable entry shall be Top entry type.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall be of form 4 type separation.The board shall confirm IS 8623 standards.The panel must be compatible with mode bus communication protocol for BMS.INCOMER: 200A FP MCCB - 1 no ,OUTGOINGS: 125A ,25KA,TP MCCB - 2 nos, 100A ,25KA,TP MCCB - 2 nos,40A 4P MCB-2Nos
1
-
-
... More
Supply , installation testing and commissioning of of 50 KVAr APFC panel with block reactors.The panel must be cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections .The voltage rating of the Power Factor correction requirement shall be at 440 Volts between phases.Permissible over rating shall be 1.5 In, 1.5Vn, 1.2fn as per IS.The total KVAR shall be divided into automatically switched steps of suitable rating.By using Microprocessor based VAR controller which will be able to sense the reactive current requirement and switch on the required VAR providing intelligent switching based on actual value of KVAR and Bank size.The no. of switching stages shall be designed appropriately in steps of 5*3,15*1 & 10*2 for 50 KVAr. The capacitor stages will be switched in rotation to equalise working hours. Individual Capacitors shall be of 3 phase construction in design using Heavy Duty Polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes.Dielectric material shall be low loss, less than 0.3 watts per KVAr. The controller should be fully automatic, intelligent microprocessor based relay operated offering minimum 8 stage (including provision for dummy chambers). All live parts are segregated and shrouded ( busbars, Inter‐Connecting copper forms and terminals ) as per National Electricity Code.For forced ventilation fans must be provided.
1
-
-
... More
Supply installation testing and commissioning of 250 KVA, Diesel Generating Set with CPCBII approved acoustic enclosure comprising of radiator Cooled Diesel engine 1500 RPM, complete with standard accessories. Coupled to alternator with rated at 250 KVA at 415 Volts mounted on Channel Iron Base Frame complete with Manual Control System with Fuel Tank ,Batteries and battery charger. The generator control panel with necessary breakers, ammeters, voltmeter,energy meter,relays,and other accessories as per the Electrical inspectorate standards must be provided. The DG set msut be compatible with mod bus communication protocol for BMS.
1
-
-
... More
Supply and installation plate earth electrode of 1200mm x 1200mm x 12.5mm size thick cast iron plates as per ISI standards including funnel, clamps, bolts and nuts, charcoal and salt filling ,chamber cover etc., as per IS 3043
6
-
-
... More
Supply installation testing and commissioning of Passenger lift having a capacity of 13 passengers, minimum rated load of 884 kg. The minimum net inside car area is 2.06sq.m and maximum net inside car area should be 2.20 sq.m . The lift must have a minimum speed of 1.5 mps and 2 stops. The lift car must be of anti- vandal SS finishes, SS 304/better life grade steel shall be used for all steel parts like Handrail, Landing (Faceplate, Frame, Buttons). The Interior shall be with Half size mirror, beige interior shades or similar shade as approved, Granite flooring with approved shade, Braille enabled on push buttons with LCD display inside Car panels and White Dot Matrix / equivalent in landing panels.The lift must have the standard features like anti nuisance car call protection, over load device, emergency car light unit, emergency alarm button, infrared curtain door protection,door time protection,automatic operation for car fan, Provision for music system wiring (in travelling cable) Voice announcement unit, Overload function with audio-visual indication in car operating panel, Fire man switch with Fireman operation,car call cancellation by double pressing floor button in car operating panel,full door Infra-red screen for car door. The lift must have potential free Building Monitoring System (BMS) contacts / RS485. The lift and its installation shall conform to relevant IS standards.
1
-
-
... More
Supply and fixing Fully Solid Vertical Air terminals as per IS/IEC -62305 part-3,16mm rod tapered to 10 mm aluminium rod meter rod Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform.Stainless Steel Wall Clamp/16 KG stone of 365 mm diameter, high level of stability. No of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. Govt approved Indian labs test certificate required. 2 meter air terminal with necessary mounting accessories Similar to Cape or equivalent in approved make list.
2
-
-
... More
FIRE FIGHTING
-
-
-
... More
Supply and installation of DCP type ABC 5Kg Stored Pressure Fire Extinguisher complete with initial charges discharge
12
-
-
... More
Supply and installation of suspended Clean Agent type Fire extinguisher filled with HFC 227ea with approved make. 5Kg capacity
6
-
-
... More
FIRE DETECTION
-
-
-
... More
Supply, installation, Testing and commissioning of 1 Loop Micro processor based alam panel with 2 wire fault tolerant loop. Loop shall have the capability of connecting 126 devices.The panel should have inbuilt TCP/IP communication for Panel Program and Modbus TCP/IP comminucation to integrate with BMS (EXCLUDED). The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 2000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display, and analog output.The Panel Should have protection caregory of IP30. Also the panel should have the option to operate in manned and unmanned mode.The panel shall have a built in power supply and battery charger along with maintenance free 7 AH,x 2 nos 12 volt SMF Lead acid batteries battery charger complete as requiredand as per specifications and Duly Approved by UL & FM.
1
-
-
... More
Supply, Installation, Testing and Commissioning of Sealed Lead Acid battery
2
-
-
... More
Supply, installation, Testing and commissioning of Intelligent Analog Addressable type Multi Detector without inbuilt Isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required.Duly Approved by UL & FM
50
-
-
... More
Isolator base / Module, either for every 20 devices or as per design (optional)
5
-
-
... More
Supply, installation, Testing and commissioning of Wall/Ceiling Mountable Sounder cum Strobe, 24V , Minimum 80 DB sound emission. LED light as strobe unit.
6
-
-
... More
Supply, installation, Testing and commissioning of addressable Manual call point. The Manual call points shall be resettable pull down type with flexi element and shall include a test key feature for the rapid testing of the device without removing the glass. The call point duly approved by UL & FM
6
-
-
... More
Supply and Installation of addressable Input Monitor modules with input contact to integrate 3rd party equipment alarms to FACP, duly approved by UL & FM Make.
7
-
-
... More
Supply, installation, Testing and commissioning of addressable Output control relay modules with NO and NC contact to trigger 3rd party equipments.Duly approved by UL & FM
7
-
-
... More
Supply, installation, Testing and commissioning of 2Cx1.5 Sq MM Red coloured PVC sheathed fire-rated, armoured Copper conductor cables are laying Surface/recessed in the wall and ceiling with ISI mark.
850
-
-
... More
Supply, installation, Testing and commissioning of response indicator
15
-
-
... More
FIRE SUPPRESSION
-
-
-
... More
Supply installation Testing & commissioning of CCOE Approved UL Listed Seamless FK 1230(FK-5-1-12) Cylinder and Valve Assembly, 140 Ltrs.capacity, OEM Factory filled with FK 1230(FK-5-1-12) Suppression Liquid (item No. 2), pressurised to 42 bar. Tank Bracket. 140 ltr cylinder PESPO approved cylinder assembly.
8
-
-
... More
Supply installation Testing & commissioning of FK 1230(FK-5-1-12) Fire Protection Fluid, UL / FM Listed.
573
-
-
... More
Supply installation Testing & commissioning of Primary Cylinder Accessories :
Electric Cum Manual Actuator 1.5" Discharge Hose Flexible Warning Sign
1
-
-
... More
Supply installation Testing & commissioning of Secondary Cylinder Accessories:
Pressure operated control head 1.5" Discharge Hose Flexible Actuation Hose. Tee connectors
6
-
-
... More
Supply installation Testing & commissioning of Tertiary Cylinder Accessories:
Pressure operated control head 1.5" Discharge Hose Flexible Actuation Hose, Master Cylinder Adaptor kit, Elbow connectors
1
-
-
... More
Supply installation Testing & commissioning of Manifold Check Valve.
8
-
-
... More
Supply installation Testing & commissioning of Nozzles, 360 Deg / 180 Deg Throw, selection as per approved hydraulic flow calculations.
24
-
-
... More
Supply installation Testing & commissioning of Cylinder Strap for 140 Lt IS Cylinder
16
-
-
... More
Supply installation Testing & commissioning of Manifold Discharge Pressure Switch
1
-
-
... More
Supply installation Testing & commissioning of Manifold Discharge Pressure Switch
8
-
-
... More
Supply installation Testing & commissioning of Manifold (8 way)
1
-
-
... More
Supply installation Testing & commissioning of Suppression System Piping Sch-80/40; ASTM A 106 Gr B, for Piping Piping shall be as per flow calculations for the specific hazard volume.
1
-
-
... More
Supply installation Testing & commissioning of Manual Abort Stations.
1
-
-
... More
Supply installation Testing & commissioning of Manual Release Stations.
1
-
-
... More
Supply installation Testing & commissioning of Hooter Cum Flasher.
3
-
-
... More
Supply installation Testing & commissioning of Fire Alarm Cum Gas Release Control Panel (2-Zone).
1
-
-
... More
Supply installation Testing & commissioning of Smoke / Heat Sensor Detector.
20
-
-
... More
Supply installation Testing & commissioning of Response Indicatior.
8
-
-
... More
Supply installation Testing & commissioning of 2Core x 1.5 sq.mm Cu. Conductor FRLS Armoured Cable
350
-
-
... More
Supply installation Testing & commissioning of Manual Release Stations.
30
-
-
... More
System Design, Installation, testing, commissioning and assistance for Fire NOC - FDA System
1
-
-
... More
HVAC Items
-
-
-
... More
Supply, Installation, Testing and Commissioning of of VRF Outdoor Condensing Unit with Variable Speed Invertor Driven Compressor and Micro-Processor Controls
16 HP
1
-
-
... More
Supply, Installation, Testing and Commissioning of of VRF Outdoor Condensing Unit with Variable Speed Invertor Driven Compressor and Micro-Processor Controls
24 HP
1
-
-
... More
Supply, Installation, Testing and Commissioning of Ductable VRF Indoor unit 8.0 TR (10HP) including supply of Wireless Remote Controllers
1
-
-
... More
Supply, Installation, Testing and Commissioning of Ductable VRF Indoor unit 6.4 TR (8HP) including supply of Wireless Remote Controllers
3
-
-
... More
Supply, Installation, Testing and Commissioning of Cassette Type VRF Indoor unit 3.2 TR ( 4.0 HP) including supply of Wireless Remote Controllers
1
-
-
... More
Supply, Installation, Testing and Commissioning of Cassette Type VRF Indoor unit 2.4 TR ( 3.0 HP) including supply of Wireless Remote Controllers
1
-
-
... More
Supply, Installation, Testing and Commissioning of Cassette Type VRF Indoor unit 1.6 TR ( 2.0 HP)
1
-
-
... More
Supply of REFNET Header / Branches / Panel Multi kit and Outdoor Unit Connection Kit
Multi kit
6
-
-
... More
Supply of REFNET Header / Branches / Panel Multi kit and Outdoor Unit Connection Kit
Outdoor Unit Connection Kit
1
-
-
... More
Supply, Installation and Testing of Copper Refrigerant Piping with Nitrile Rubber insulation-13mm for Liquid pipe & 19mm for Gas pipe , support brackets, hangers/fixtures
155
-
-
... More
Supply installtion testing and comissioning of GSS (Galvanised Standard Sheet) Ducting of following gauges. 24 SWG Ducting
137
-
-
... More
Supply & installtion of Fire Retardant Flexible Canvas Connector - FCU to Ducting.
4
-
-
... More
Supply & installtion, Testing and Commissioning of grills without damper
6
-
-
... More
Supply and fix Acoustic Duct Lining with 10mm Thick Nitrile Rubber Open Cell Insulation for noise reduction inside inside the Ducting: K-Flex or equivalent
50
-
-
... More
Supply and fix Closed Cell Nitrile Rubber Thermal Insulation 9mm Thick, Class "O" to the exterior of the ducting K-Flex or equivalent
87
-
-
... More
4C x 16.0Sq. mm Flexible Cable to connect Power to Outdoor Units from Local Isolators supplied by others
25
-
-
... More
3C x 2.5 Sq. mm Flexibel Cable to connect Power to Indoor Units from Local DP Switches supplied by others
20
-
-
... More
2C x 1.5 Sq. mm Sheilded Flexible Cable for Networking between Indoor Units to Outdoor Units
165
-
-
... More
Drain piping -PVC with 6mm Nitrile Rubber sleeves
50
-
-
... More
Additional Refrigerant Charge (R410A)
20
-
-
... More
Supply and Installation of Underdeck Insulation with 50mm Thick polystyrene.
1350
-
-
... More
Supply and installtion of Pedestal 200mm
2
-
-
... More
OPERATION AND MAINTENANCE
-
-
-
... More
Maintenance charges per month for fourth year
12
-
-
... More
Maintenance charges per month for fifth year
12
-
-
Evaluation Notes How It Works ?