Smart City Thiruvananthapuram Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Smart City Thiruvananthapuram Limited Tender

Works
Civil And Construction
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date19 May 2023
Closing Date1 Jun 2023
Tender Amount₹ 43,33,897 
Notes
Download

Costs

Summary

Selection Of Contractor For Development Of Smart Roads And Underground Ducting Including Utility Shifting Of Water Supply And Power Lines In Abd Area Under Smart City Mission In Thiruvananthapuram Sree Chitra Road Id 179

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of sub-grade and earthern shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and comapcted to meet requirement of table No. 300-2.

247.5

-

-

... More
Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mixing in place method with rotovator at OMC, and compacting with vibratory roller to acheive the desired density, complete as per clause 401. br Grading-V-For sub base cum drainage layer - Mix in place method.

99

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

74.25

-

-

... More
Supplying and laying interlocking tile 80mm or nearest size thickness, minimum strength M30 including providing a layer of 6mm aggregate for 5cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc. complete.

450

-

-

... More
IRISH DRAIN AND MANHOLE

-

-

-

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres. Prestressed / Reinforced cement concrete grade M-20 & above. - By Manual Means

9

-

-

... More
Based on MORTH Item No.2.4.2.A - Extra for additional lead of every 1 Km part thereof for disposal of dismantled waste material by mechanical transport to approved municipal waste dumping yard,as per the direction of Engineer In-charge

174.08

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.

288.08

-

-

... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.

16.67

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications PCC Grade M20 - Using Concrete Mixer -

88.87

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M25 - Using Concrete Mixer -

12.64

-

-

... More
Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specificationseans.

4.66

-

-

... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC Using Concrete Mixer on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409

90

-

-

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

337.5

-

-

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V : 20H towards drawing foce.Complete as per drawing and Technical Specifications

10

-

-

... More
od206439/2019_2020 Based on D.S.R-19.19.4.1-Supplying and fixing SFRC Circular shape 560 mm dia precast R.C.C.manhole cover(Extra Heavy Duty) with frame - EHD - 35 to existing manhole cover slab including necessary fixing charges labour etc. complete.

8

-

-

... More
Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

20

-

-

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

80

-

-

... More
WATER SUPPLY WORKS

-

-

-

... More
Supply of PVC Pipe, 8kg/cm2, 110mm Dia Including all specials, conforming to IS 4985: 2000.(KWA Data-100.98.224)br

100

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).110 mm nominal outer dia pipes.(From KWA Data-100.9.11)

100

-

-

... More
Boring RCC slab above 8cm and upto 10cm thick for providing pipes or fittings of size 80 to 100mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. NEW DATA (Prepared based onbrPHED SDB Vol II - Item No.1063) (As per KWA Data 100.41.26)

4

-

-

... More
Boring RCC slab above 8cm and upto 10cm thick for providing pipes or fittings of size 50 to 60mm and rectifying slab with cement concrete 1:2:4 using 20mm broken stone and finishing the top and bottom with cement mortar after placing the pipe or fittings. brNEW DATA (Prepared based onbrPHED SDB Vol II - Item No.1063) (As per KWA Data 100.41.22)

30

-

-

... More
Inter connection to the branch lines from newly laid PVC main lines

3

-

-

... More
Inter connection with existing DI K9/CI/GI/PVC to newly laid lines including dismantling existing lines,cost of necessary fittings required for interconnection work,all labour charges etc complete.(As per data from KWA).

2

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm.(As per KWA Data-100.98.482).

1

-

-

... More
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class IbrData derived from item no.18.31.1.1of DAR(As per KWA Data-100.31.1.2)

1

-

-

... More
Supply of 560mm dia CI MH cover with frame.(Data as per KWA)

2

-

-

... More
Supply of Solid block of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979.

0.2

-

-

... More
Engaging Coolie for Controlling Valves (From KWA Data-100.98.1008)

7

-

-

... More
Engaging Assistant Fitter or 2nd Class fitter (As per KWA Data-100.98.1010).

7

-

-

... More
Engaging Fitter ( grade 1) for giving Interconnection and Rectification of leak during Works (From KWA Data- 100.98.1009)

7

-

-

... More
Providing New/Alteration of house connection from the existing main including earth work excavation,supplying and fitting suitable saddle piece,supplying and fitting 20 mm brass ferrule1 no,20 mm GM full way wheel valve 1no,bend 1no union 1no etc. and connecting the newly laid main,testing the joints etc complete but excluding cost of pipe.(Data as per the data from KWA).

15

-

-

... More
Disconnecting water connection from service mains along Asphalt road without causing any damage to the existing line including charges of earth work excavation in all kinds of soil for exposing connection point including tar cutting / conrete cutting, making the disconnection point water tight charging and testing to the required pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other existing utilities, including the charges of hire for tools and plant, conveyance of tools and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion but excluding cost of materials and as per the direction of departmental officers etc. complete.(KWA Data-100.51.3).

3

-

-

... More
od250528/2019_2020 Supply and Conveying 20mm ASTM Pipe, conforming to IS 4985:2000(Rate as per date from KWA).

100

-

-

... More
ADDITIONAL ITEMS-WATER SUPPLY LINES

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia DSR 2.10.1.2

120

-

-

... More
Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (KWA Data 100.8.1)

150

-

-

... More
Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. 100.59.1

200

-

-

... More
Bailing out water with 5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete. NEW DATA (Prepared based on PHED SDB - Item No.1070

80

-

-

... More
Supply of PVC Pipe, 8kg/cm2, 160mm Dia.Rate inclusive of all specials.(As Per KWA DSR-100.98.226)

100

-

-

... More
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).160 mm nominal outer dia pipes.(From KWA Data-100.9.11)

100

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm.(KWA Data-100.98.484)

1

-

-

... More
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 150 mm diameter. Class I" Data derived from item no.18.31.3.1 of DAR (As per KWA Data-100.31.1.4)

1

-

-

... More
VALVE CHAMBER

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

5.85

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

0.45

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations,footings, bases for columns

21.76

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size (5.1.2)

3.01

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo - Mechanically Treated bars of grade Fe-500 D or more

301.35

-

-

... More
UTILITY SHIFTING OF ELECTRICAL POWER SUPPLY LINES-MATERIAL

-

-

-

... More
Supply of Metallic feeder pillar box with 300 amp LB SW on both ends 24 nos of O/G terminals (1ph)with SFU for giving service connections (16amp to 62amp as per requirement).provision for cable entry on both sides, cable connecting facilities, phase indicators, volt meter and ammeter, danger labeling etc Make: Subjected to approval from KSEB

2

-

-

... More
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 2x4 sq.mm

100

-

-

... More
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 4x6 sq.mm

300

-

-

... More
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 3.5x25 sq.mm

100

-

-

... More
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 3.5 x 185 sq. mm

100

-

-

... More
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 3.5 x 150 sq. mm

150

-

-

... More
Supply of LT Heat Shrink Straight Jointing Kit suitable for cable of size 4 x 6 sqmm upto 4 x 16/ 3.5 x 25 sqmm

5

-

-

... More
Supply of LT Heat Shrink Straight Jointing Kit suitable for cable of size including 3.5 x 150 sqmm upto 3.5 x 240sqmm

2

-

-

... More
Supply of one number PVC insulated single-core copper conductor cable of the following size 2.5 sq.mm

120

-

-

... More
Supply of one number PVC insulated single-core copper conductor cable of the following size 4 sq.mm

100

-

-

... More
Supply of one number PVC insulated single-core copper conductor cable of the following size 6 sq.mm

100

-

-

... More
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 32mm dia

100

-

-

... More
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 40mm dia

300

-

-

... More
Supplyof following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 63mm dia

100

-

-

... More
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 90mm dia

150

-

-

... More
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 110mm dia

100

-

-

... More
Provision for feeder pillar earthing (earth pipes, gi wires/plates, earthing Chemicals)

4

-

-

... More
Supply of 1Ph dust & vermin proof and weatherproof FRP meter box with 16 Amps cut out fuse and neutral link

1

-

-

... More
Supply of 3Ph dust & vermin proof and weather proof FRP meter box with 32 Amps cut out fuse and neutral link

1

-

-

... More
Supply of 3Ph CT dust & vermin proof and weatherproof FRP meter box with 32 Amps cut out fuse and neutral link

1

-

-

... More
Supply of 1.5mtr earth pipe for meter box earthing

3

-

-

... More
Supply of 10SWG Copper earth wire

3

-

-

... More
UTILITY SHIFTING OF ELECTRICAL POWER SUPPLY LINES-LABOUR

-

-

-

... More
Laying of one number armoured aluminium power cable of 1.1KV grade of the following sizes in the existing HDPE pipe/duct as per the direction of the engineer in charge. 3.5 x 150 / 3 x 150 sq mm.

150

-

-

... More
Laying of one number armoured aluminium power cable of 1.1KV grade of the following sizes in the existing HDPE pipe/duct as per the direction of the engineer in charge. 3.5 x 185 sq mm

100

-

-

... More
Excavation of cable trench in all classes of soil and backfilling of the trench after laying cable (3.5x120mm sq), (3.5x150mm sq), (3.5x185mm sq)

50

-

-

... More
Additional rate for excavation of cable trench in exceptionally hard condition(like ordinary rock) (3.5 x120mm sq) , (3.5x150mm sq), (3.5x185mm sq)

50

-

-

... More
Digging and laying LT 3.5 x 25 sq mm cable including providing HDPE pipe for looping cables from pillar box to consumer premises etc as per the direction of engineer in charge.

100

-

-

... More
Digging and Laying LT cable 4x6 sq mm (Three-phase service connection & Street light) including providing HDPE pipe for looping cables from pillar box to consumer premises etc as per the direction of engineer in charge.

300

-

-

... More
Digging and Laying LT cable 2x4 sq mm (Single-phase service connection) including providing HDPE pipe for looping cables from pillar box to consumer premises etc as per the direction of engineer in charge

100

-

-

... More
Charges for the erection of feeder pillar box (24 nos outgoings) including Plinth and earthing

2

-

-

... More
Shifting of single phase connection on newly erected meter box, including erection of meter box, earthing, wiring up to DB and other connections

1

-

-

... More
Shifting of three-phase wp service connection on newly erected meter box, including erection of box, earthing, wiring up to DB and other connections

1

-

-

... More
Shifting of CT three-phase wp service connection on newly erected meter box, including erection of box, earthing, wiring up to DB and other connections

1

-

-

... More
Surveying the cable route, Collecting consumers data, measuring cable length to consumers, Pole var details collection, Pillar box and Distribution box marking, preparing Sketch etc.

1

-

-

... More
Doing straight joint on cables of sizes beyond 4x6 sqmm and upto and incl. 4x16 sq mm/ 3.5 x 25 sqmm using the cable jointing kit

5

-

-

... More
Doing straight joint on cables of sizes beyond 3.5x70 sqmm and upto and incl. 3.5x150sq mm using the cable jointing kit

1

-

-

... More
Doing straight joint on cables of sizes beyond 3.5x150 sqmm and upto and incl. 3.5x185 sq mm using the cable jointing kit

1

-

-

... More
UTILITY SHIFTING OF ELECTRICAL POWER SUPPLY LINES-ADDITIONAL ITEMS

-

-

-

... More
Supply and fixing of 20mm size of medium class PVC conduit along with accessories in surface / resess including cutting the wall and making good the same in case of recessed conduit as required.

50

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

20

-

-

... More
Supply, Installation, Testing and commissioning of LED steet light with output 120 lumen/W ,3000-6000 K with IP 66 protection, total output of 8000 lumen above LED Chip make Cree/Lumilled/Nichea with power factor 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD 10%, power factor 0. 98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

4

-

-

... More
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

4

-

-

... More
Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required 160 mm dia (OD-160 mm & ID-135 mm nominal

100

-

-

... More
Supplying,installation,testing and commissioning of Astronomical time switch capable of following output in feeder pillars I Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply

1

-

-

... More
OPERATION AND MAINTENANCE

-

-

-

... More
Maintenance charges of road work and other components except land scaping per month for fourth year

12

-

-

... More
Maintenance charges of road work and other components except land scaping per month for fifth year

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.