Smart City Thiruvananthapuram Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Smart City Thiruvananthapuram Limited Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date3 Feb 2024
Closing Date12 Feb 2024
Tender Amount₹ 1,72,46,811
Costs
EMD
₹ 50,000Document Cost
₹ 6,505Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SCTLT_654090_1Bid Award Id
ViewTender No
SCTL/TECH/408/2024/AM-C/RFP-59Tender Authority
Smart City Thiruvananthapuram Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
special instruction for electrical work
BOQ Items
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above
2.52
-
-
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead.
192.9
-
-
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
24.94
-
-
Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually / by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge:In cement mortar
8.75
-
-
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
21.93
-
-
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
5.17
-
-
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
95
-
-
CIVIL WORKS
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
48.28
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.56
-
-
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
120.9
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13298.78
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1.84
-
-
Filling with available fly ash and earth ( excluding rock) in trenches or embankment in layers ( each layer should not exceed 15 cm), with intermediate layer of compacted earth ( Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer - in- charge, including compacting each layer by rolling / ramming and watering, all complete as per drawing and direction of Engineer - in-charge
128.03
-
-
Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5
conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1
cement : 6 coarse sand):With Modular bricks
374.01
-
-
12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
1944.6
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
2472.62
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
2472.62
-
-
Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.8 mm thick (mirror polished and machine cut edge)Granite stone of any colour and shade
8.28
-
-
Supplying of 12 mm thick clear acrylic sheet
57.32
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
867.33
-
-
Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
107.76
-
-
FLOORING
-
-
-
Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern
1069.45
-
-
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-inCharge
74.44
-
-
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge
391.2
-
-
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement
192.9
-
-
Providing and laying flamed finish Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all completeas per the architectural drawings with 18 mm thick stone slab over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid andjointed with cement slurry and pointing with white cement slurry admixed withpigment of matching shade including rubbing, curing and polishing etc. allcomplete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent
164.4
-
-
STEEL WORK
-
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
725.68
-
-
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
1.65
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
725.68
-
-
Providing and fixing Pre-laminated medium density fibre board IS:14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I (exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately).Pre-laminated with decorative lamination one side and other side balancing laminaion exterior Grade-I MDF Board 18mm thick confirming to IS:14587.
19.32
-
-
Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
14.17
-
-
SANITARY INSTALLATIONS
-
-
-
Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately) 1. Below 15 flush capacity
1
-
-
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern
2
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2
10
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
20
-
-
WIRING
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
20
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
200
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
100
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
50
-
-
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
20
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
5
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
8
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
4
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
4
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
3
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
250
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
150
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
100
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
20
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
10
-
-
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings)
6
-
-
LT CABLES AND END TERMINATION
-
-
-
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
500
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 10 sq mm
350
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 16 sq mm
120
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 4 sq mm
300
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 6 sq mm
800
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
400
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm
10
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 25 sq mm
25
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
50
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
16
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
100
-
-
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
1800
-
-
DISTRIBUTION BOARDS AND PANELS
-
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4+12), Double door
1
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+4 way, Double door
5
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
45
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
9
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
3
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
1
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
6
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
15
-
-
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
6
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
Supply and Installation and Testing and Commissioning of Outdoor box with necessary accessories suitable for mounting 2/3 Module(Dimensions: 100 x 150 x 96 mm) MCBs with Transparent glass, with protection class IP65, 1 Row, 3 available modules, Rated operational voltage: 400V AC, Rated insulation voltage: 1000V AC, 1000V DC, metric knockouts on top and bottom for universal cable insertions with cable glands and/or double membrane seals, elastic entries double membrane seals M20 on top with PE/N terminal rail, each with 1 clamping point 16 mm² and 3 terminal points 6 mm² Accessories supplied: Double-membrane seals: 1x M25, sealing plugs, masking and labelling strips.brElectrical characteristics: Rated operating voltage AC: 400 V, Rated insulation voltage AC: 1000 V, Protection class: II ,Type of protection: IP65. brMaterial: Base unit material: Polycarbonate, Cover material: Polycarbonate, glass-fibre reinforced, Sealing material: Polyurethane, Cover screw material: Polyamide, glass-fibre reinforced, Hinged window material: Polycarbonate.brMaterial characteristics: UV-resistant: yes, Halogen free: yes, Flammability class according with UL94: V2, Glow-wire flammability according to EN 60695-2-11: 960 °C.brMechanical properties: Type of fastening: Surface mounting, Impact strength: IK08, Sealable: yes, Cover screw torque: 1.2 Nm.brMake : Spelsberg, Model no. AKi 03 or equivalent.
5
-
-
Supply and Installation and Testing and Commissioning of Outdoor box with necessary accessories suitable for mounting 4 Module(Dimensions: 125 x 200 x 122 mm) MCBs with Transparent glass, with protection class IP65, 1 Row, 5 available modules, Rated operational voltage: 400V AC, Rated insulation voltage: 1000V AC, 1000V DC, metric knockouts on top and bottom for universal cable insertions with cable glands and/or double membrane seals, elastic entries double membrane seals M20 on top, with PE/N terminal rail, each with 2 terminal points 16 mm² and 3 terminal points 6 mm² Accessories supplied: Double-membrane seals: 1x M25, sealing plugs, masking and labelling strips.brElectrical characteristics:Rated operating voltage AC: 400 V, Rated insulation voltage AC: 1000 V, Protection class: II, Type of protection: IP65.brMaterial: Base unit material: Polycarbonate, Cover material: Polycarbonate, glass-fibre reinforced, Sealing material: Polyurethane, Cover screw material: Polyamide, glass-fibre reinforced, Hinged window material: Polycarbonate.brMaterial characteristics: UV-resistant: yes, Halogen free: yes, Flammability class according with UL94: V2, Glow-wire flammability according to EN 60695-2-11: 960 °C.brMechanical properties: Type of fastening: Surface mounting, Impact strength: IK08, Sealable: yes, Cover screw torque: 1.2 Nm.brMake : Spelsberg, Model no. AKi 05 or equivalent.br
5
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
400
-
-
Supply and installation of 1.5 meter 32 mm Medium class earth pipe for Meter box Earthing
12
-
-
Earthing with G.I. earth pipe 3 metre long, 40 mm dia including accessories, and providingbrmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withbrcharcoal/ coke and salt as required
2
-
-
LIGHT FITTINGS
-
-
-
Supply and Installation testing and commissioning of Bollard lights 15W Cylindrical shaped powder coated aluminum pressure die housingbrRobust and stylish which ensure low cost of ownership with a low glare, clear acrylic diffuser allows an attractive visual comfort with good downward symmetrical light distribution, More than 65% energy savings compared to conventional lighting solution. IP65, High Ingress protection against dust & moisture Wattage: 15WbrSize : Dia. - 80mm, Height -400 to 1000 mm,Diffuser: UV Stabilized opal one piece PMMAbrHousing types: Powder Coated Aluminium tubular sections Lamp types & Wattages: LED :15W,LED Make:OSRAM ,Ingress Protection: Optical Compartment IP66 Lengths : 400 to 1000 MMbrRated Voltage & Frequency : 240V, 50Hz,THD 10%,Power Factor : 0.95,CCT : 3000K,Driver Efficiency : 85%br
75
-
-
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
22
-
-
Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
44
-
-
Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4
-
-
Supply, Conveyance, installation, testing and commissioning of 60W LED Decorative Post top light Made in diecast aluminium housing with decorative clear and opal acrylic diffuser with IP65 protection Similar to Bajaj make BFC FLO 60W LED WW OP PT or equivalent Philips/Wipro etc.
12
-
-
Supply and Installation of 3 Metre decorative Pole Galvanized thickness shall be 35 Microns. Tolerance on thickness and dimensions shall be as per relevant standards. The external surface of the pole shall be finished by poluurethane paint(50 microns). Paint: PU Matt Black (Any other Ral colour on Request and confirmation).Grade of pipe: YST 210. Tolerance: 15mm.Bottom shall be minimum height of 1.2M with bottom dia of the shall be 114 m. The uppersection shall be not less than with minimum dia of 60 mm.Bottom shall be provision for mounting of 1no of MCB, stud terminals suitable for 4 core 6 sq mm cable lilo and earthing. The Pole is to be a suitable surface mounting Base plate with thickness 10mm and 200 PCD. and welded at the bottom ofthe with supporting gussets Pole shall be mounted on square base plate, suitable for mounting on 4 nos bolts. similar to Bajaj make: BJPL ECO 3M PT Pole or equivalent Philips/Wipro etc. foundation 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) foundation in size of 250 MM X 250 MM X 600 MM (Length X width X Depth), foundation bolts of the bollard light shell be grouted in the foundation with 2 coat painting of each foundation with Exterior plastic emulsion paint including plaster, putti etc. as required for smooth surface or as per the OEM design
12
-
-
Supply and Installation testing and commissioning of Tree up lights 40 W Architectural Functional LED Flood Light for Installation on Pole /Wall / Ground Mounting, Made of Die-cast Aluminium housing. Glass diffuser: extra clear, fixed through a robotic gluing system & provided with SS 304 Allen Screws. The luminaire has three connected parts: wiring unit (silicone gasket), heat sink and emitting unit (silicone glue). A graduated fixing plate allows a precise adjustment of the emitting unit. The entire painting process of the Aluminium fitting starts from components which have been sand-blasted in advance to make the surface more porous and increase the adherence of the paint. Protection rating: IP66.brClass of insulation: Class IbrInstallation: the luminaire is equipped with 300mm of cable for an easy-to-make connection. LED service life lasts 50000 h before luminous flux is reduced to 80% of the initial value.brChromaticity tolerance (initial MacAdam): 3. Colour temperature RGBW. Luminaire wired with halogen-free leads. Wattage : CREE XML LED, CRI: 70,LED Make:OSRAMbrCCT: RGBW,brOptics : 90°,Lumen: 3610 (delivered), Controls: DMX, Finishbr: Grey, Weight: 4.1Kg, Driver: Meanwell / Inventronics, Accessories: Male / Female IP 68 Connectors / Glare Louvers / Knuckle Jointbr
30
-
-
Supply, Conveyance, installation, testing and commissioning of 9W Spike/Bush Light .Spun aluminium graphite grey powder coated housing with PDC bottom. Graphite grey powder coated die-cast aluminium alloy spigot. High class LED with Warm White COB technology for better output. Constant current electronic driver provided with high voltage, open & short circuit protectionInput Voltage: 140V to 270V AC, Input Frequency: 50 Hz, System Current in Amp. @240V AC: 0.04A, Power Factor: 0.95 THD: 10%, Built-in Surge protection: 4 kV, Ingress Protection: IP65, Impact Protection: IK06.similar to Bajaj make:- Product Cat. Ref. BGSBL 9W WW LED Product Code 112146 or equivalent wipro/Philips..etc
30
-
-
Supply, installation, Testing and Commissioning of 40W LED Decorative Post top Luminaire, BIS certified with a grey painted top made high pressure die casted aluminium and three supporting ribs made of high pressure die casted aluminium, a structured polycarbonate protector (IK08) permanently sealed with the body to achieve separate IP66 optical & IP65 control gear compartments. Suitable for post top mounting on 76mm OD diameter pipe. All hardware shall be of stainless steel for longer life.The optics of the luminaire shall be designed for efficient symmetric light distribution providing excellent photometry. Design life shall not be less than 50,000 burning hours @ L70. The light engine shall incorporate mid power LEDs in the Luminaires.Overall luminous efficiency of luminaire shall be 100 Lm/W ± 7% at correlated colour temperature (CCT) of 3000K with tolerance as per ANSI standard , colour rendering index (CRI)70. Electrical Class I, rated voltage 240Vac, Power Factor 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV . Shall be supplied pre-cabled (0.3m) for easy installation.Protection features: Short Circuit and Open Circuit Protection for LED. It should survive input voltage stress of 440V for 8 hours. Model : kesslec Wels 40W WW LED post top or Equivalent model
22
-
-
Supply and Installation of 3m height decorative pole made of mild steel/steel tube with IS 1161/IS 3601, minimum of not less than 2. mm thickness. It shall have Mo sections. Bottom shall be minimum height of 1M with bottom dia of the shall be 114 m. The uppersection shall be not less than with minimum dia of 76 mm. The Pole is to be a suitable surface mounting base plate (steel of grade to IS 2062: 2011) and welded at the bottom ofthe with supporting gussets Pole shall be mounted on square base plate, suitable for mounting on 4 nos bolts. The Pole Shaf pipe should be fabricated out of Steel tube of grade YST 2101240. The pole shaft and base plate shall be hot dip galvanized (7 Stage process) as per IS 2629 before the coating of epoxy primer. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. Complete pole shall be treated with high quality epoxy zi rich penetrating primer 45 microns and thereafter coated with Polyurethane paint to minimum average DFT of Controlled paint drying process shall to ensure proper adhesion and finish of the paint. pole shall provide with Marine grade Painting. T shall conform to IS 12944 for CS Mx ist of 6A MCB with built in terminals for housing 3.5 core Sq MM armoured aluminium cable. The pole shall of ‘composite’ construction designed to specified ‘dead load’ pertaining to luminaire and its mounting ac@ssories and ‘wind load’ corresponding to a basic wind speed of 169kmph without any deformation or damage the structure. Decorative Hot dipped Galvanised bracket on the post top and at differential height tightned to pole with stainless steel grub screws to mount luminaries and for mounting the fittings with foundation 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) foundation in size of 250 MM X 250 MM X 600 MM (Length X width X Depth), foundation bolts of the bollard light shell be grouted in the foundation with 2 coat painting of each foundation with Exterior plastic emulsion paint including plaster, putti etc. as required for smooth surface or as per the OEM design.
22
-
-
Supply and Installation testing and commissioning of Step Light LED 12 W, exterior-rated architectural floodlight 12W, Luminaire . Rated input supply of Input Voltage 120-277 VAC, 50/60Hz ., LED Make : OSRAM . Lumen Maintenance 50,000 hrs L70 at 35°C .brColor - Dark GreybrBIS Certified Mandatory. The fixtures proposed must have passed LM79& LM-80 Reports from NABL laboratory. brDiffuser: UV Stabilized opal one piece PMMAbrHousing types: Powder Coated Aluminium tubular sectionsbrLamp types & Wattages: LED : 12Wbr
100
-
-
Supply, Installation, Testing and commissioning of 6A SP MCB, 32A Neutral link along with 32A 4P connectors with necessary accessories for fixing inside Street light pole
58
-
-
Supply, Installation, Testing and commissioning of Digital timer with necessary accessories , 25A, Single phase Contractor. L&T make or Equivalent.
4
-
-