Smart City Thiruvananthapuram Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Smart City Thiruvananthapuram Limited Tender

Works
Civil And Construction
Eprocure
Opening Date28 May 2020
Closing Date20 Jun 2020
Tender Amount₹ 1,72,37,857 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 60 cm dia, and 60 cm deep

55

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 45 cm dia, and 45 cm deep

3796

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

560.02

-

-

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

339.41

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

113.7

-

-

... More
Rough dressing the trenched ground including breaking clods.

1697

-

-

... More
Fine dressing of the ground

1697

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-incharge

1037.04

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-incharge (cost of sludge, dump manure and/ or good earth to be paid separately).

1037.04

-

-

... More
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

203.65

-

-

... More
Flooding the ground with water including making kiaries and dismantling the same

1697

-

-

... More
Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.

3851

-

-

... More
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.

1697

-

-

... More
Providing and watering of irrigation water through water tanker of Horticulture features i.e.tree, shrubs, hedge/edge, ground cover etc. at the site of work. Water tanker having 5000 lit.capacity with one labour for watering i/c cost of water, filling of tanker, watering at site with all leads and lifts as per direction of officer-in-charge.Cost of 5000 Ltrs for Each Trip

194

-

-

... More
Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

47.1

-

-

... More
Providing & laying Buffalo grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, with sprinkler and maintenance for 30 days or more till the grass established properly as per direction of officer in charge

1649.9

-

-

... More
Providing and Displaying of Arabian jasmine plant of height 30 cm to 45 cm, considering 9 nos per sq.mt as per direction of the officer-in-charge.

905

-

-

... More
Providing and displaying Vinca different colour 6 to 8 well developed branch in full bloom stacked with green painted Bamboo stick in 25 cm Earthen Pot/Plastic Pot on already developed flowering bed as per the direction of Engineer in Charge

626

-

-

... More
Supply and stacking of plant Portulaca hybrid of height 20 cm. 12 per sqm , multicolor below the signage as per direction of the officer-in-charge.

2.5

-

-

... More
Providing and Displaying of Alternanthera species plant of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.

1125

-

-

... More
Providing and Displaying of plant Impatiens in different colour well developed fresh and healthy (3 in one) well bloomed in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

387

-

-

... More
Providing and displaying Lantana seellowiana well developed with fresh and healthy bushy plant in full bloom 45-60cm height on already developed flowering bed as per the direction of Engineer in Charge

78

-

-

... More
Providing and Displaying of of Chlorophytum (Green) plant, full of leafy suckers in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.

438

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100)

55

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per Shrubs plants (for 200 nos.=427.45/200)

3796

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

105.28

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

77.65

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

141.24

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

10.11

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

0.87

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

3.2

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

4.69

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

12.13

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

25.92

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

3.78

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

10.78

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

10.26

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

263.6

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

744.7

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

1.34

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :5.5 mm thick glass panes

6.65

-

-

... More
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

2.4

-

-

... More
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

37.8

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

78.67

-

-

... More
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

116.92

-

-

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

387.73

-

-

... More
9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

3.78

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

374.84

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

593.93

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

21.59

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

11.83

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

19.72

-

-

... More
Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

2

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-incharge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

38.93

-

-

... More
Providing and laying Polished Granite stone flooring in required design andpatterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed withcement slurry and pointing with white cement slurry admixed with pigment ofmatching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-inCharge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

33.1

-

-

... More
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mmthick sub grade of compacted bed of 20 mm thick nominal size stone aggregateand base course and filling with 150 mm thick jamuna sand, including spreading,well ramming, consolidating and finishing smooth etc. all complete as per directionof Engineer-in-charge.

105.57

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

267.22

-

-

... More
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.

267.22

-

-

... More
Finishing with Epoxy paint of 3mm thick coat (one coat primer, 2mm screed and 1mm finishing coat ) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.brOn concrete work

267.22

-

-

... More
Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

39.96

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

1862.47

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

348.63

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board 470x350 mm bowl depth 178 mm

4

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

4

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 15 mm dia 10 Kgf/cm2- External work - Exposed on wall

30

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall

80

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall

5

-

-

... More
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

10

-

-

... More
Providing and fixing CP brass concealed floor trap of 110 mm outer dia(multi trap) including CP cockroach free floor grating with cup etc including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer- in-charge at all levels

4

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

2

-

-

... More
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core panels made of core material of EPS granule balls/beads (conforming to IS 4671:1984 and shall have density not less than 15kg per cum) adhesive, cement, sand, flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000 or Calcium silicate board confirming to EN 14306:2009 of 5mm thick each. Panel shall be laid on 6mm thick cement mortar (1 cement: 2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement or shall be preferably fixed into 'C' channel made of 1.2mm thick MS plate screwed/fastenened to the slab/column/beam etc. The panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except "C channel" which will be paid separately).Non load bearing panels 115mm thick of required size

51.35

-

-

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

5.2

-

-

... More
Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

2.1

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

110.43

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

138.03

-

-

... More
Providing and fixing Cast iron railings, grills or gate on the existing MS section as per design, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary steel nuts and bolts complete, i/c fixing the railing with necessary accessories & dash fasteners, bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per the drawing and as per the approval of Engineer-in-charge.(MS Section weight shall be measured separately)

4055.25

-

-

... More
Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work

268.35

-

-

... More
Providing and fixing M.S. Grills of required pattern over the compound wall already constructed,etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete as per the instruction of Engineer-in-charge.

1731.75

-

-

... More
Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

19.46

-

-

... More
Supply and installation of Fibre Big Litre bin of capacity 120 ltr, including all rates etc. complete as per the direction of Engineer in charge.

5

-

-

... More
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Light shade pigment using white cement

417.59

-

-

... More
Providing & fixing 19 mm thick BWP grade ply confirming to IS- 710 for Kitchen cupboards/Shelves of size as per drawings, the door shutters also shall be made with 19mm thick BWR ply fixed with auto close cabinet hinges hinges fixed over vertical ply.Outside vertical exposed surfaces of counter finished and Inside exposed surfaces finished with 1mm thick hot pressed laminate. ( only face area to be measured) etc complete, as per the direction of Engineer in Charge

16.86

-

-

... More
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness

14.17

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

31.8

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

49.2

-

-

... More
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge

858

-

-

... More
Supplying and filling in plinth with sand for child play area including dressing complete as per the direction of Engineer in Charge

112.52

-

-

... More
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

15.9

-

-

... More
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

2.67

-

-

... More
Demolishing dry brick pitching in floors, drains etc. including stacking serviceable material and disposal of unserviceable material with in 50 metes lead:

14.33

-

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

417.59

-

-

... More
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

41.25

-

-

... More
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes(within 50 metres lead) as per direction of Engineer-in-Charge.(a) Internal Work- Exposed on wall

51.63

-

-

... More
Supply and installation of Outdoor play equipment's(S Loop Rung with Horizontal Bar)as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Rock And Roll as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

2

-

-

... More
Supply and installation of Hopping pad as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

2

-

-

... More
Supply and installation of Roller slide as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Climber as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Double bar see-saw as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Multi Play System as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Cycle as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

2

-

-

... More
 Supply and installation of Twist Stepping Machine as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Chest Press double as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Horse Press Double as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

2

-

-

... More
Supply and installation of Squat Pushing as per the specification mentioned in the technical specification including all rates including Cement Concrete foundation etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Two seater swing rubber belt for Child play area as per the specification mentioned in the technical specification including all rates etc complete as per the direction of Engineer in charge

1

-

-

... More
Supply and installation of Four seater spring see-saw for Child play area as per the specification mentioned in the technical specification including all rates etc complete as per the direction of Engineer in charge

1

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C

9

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A

27

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

20

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

25

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

35

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

25

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

1

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

5

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

1

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).

8

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

3

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.

4

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 8 way, Double door SPN MCBDB

1

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

24

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

12

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

4

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)

15

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

250

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required7.10 mm copper conductor ( 2 SWG)

20

-

-

... More
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm

1068

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)

2

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

24

-

-

... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.7.10 mm (2 SWG)

4

-

-

... More
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm

350

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm

1120

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm

340

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

20

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

15

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

30

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

2

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm

120

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

2

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

1

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

1

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

2

-

-

... More
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.brFabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)

10

-

-

... More
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

4

-

-

... More
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

-

-

... More
Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

1

-

-

... More
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board

8

-

-

... More
Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

4

-

-

... More
Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

300

-

-

... More
Supply and providing copper earth bus in the panel board

200

-

-

... More
SITC of Multifunction Meter to read V, A, F, 3 phase accuracy class 1.

1

-

-

... More
SITC of LED Indicator lamps for 230/415V - red, green, orange colour in the existing panel.

3

-

-

... More
SITC of 100/5A, 5VA, accuracy class 1, resin cast metering CT in the existing panel and giving connections as required.

3

-

-

... More
Supply and Installation of 11W LED on ground surface mounting Bollard Light with IP65 and IK10 protection, CCT 3000K, with pressure die-cast aluminum housing and polycarbonate diffuser and giving connections as required. Similar to Wipro make- Whistling bollard (LB14-131-XXX-30-08 or equivalent in Philips/jaquar

64

-

-

... More
Supply and installation of 4 Feet long slim & surface mounted IP20 batten of 20w with not less than 2000 lumens with high performance extruded aluminum as housing and high quality PC as diffuserwith CRI80 and minimum life of 25000 burning hours @L70 Make: Philips/Wipro/Jaquar

3

-

-

... More
Supply and Installation of LED STEP LIGHT IN ALUMINUM DIE CASTED POWDER COATED COMPACT, ROBUST, NONCORROSIVE ALUMINUM BODY,HIGH LUMEN OUTPUT LED,POLYCARBONATE CLEAR DIFFUSER, HIGH POWER HIGH GLARE FREE LIGHT DISTRIBUTION,IP 65 DUST TIGHT,Color temperature-5700K, IP20,50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency75%,THD15%, Powerfactor0.9, Surge protection in CM-4KV, Constant Voltage Operated driver with range 110-300V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standardbrWDESIGNED FOR INSTALLATION WITH BACK BOX ON WALL SURFACE WITH WALL CUTOUT 160 x 108 x 80 mm ±2 mm Wattage 3W,60 lumens,SIMILAR TO LT51-370-XXX-30-XX OR Equivalent in Philips/Jaquar

73

-

-

... More
Supply, Installation, Testing and Commissioning of 60W LED Street Light with Pressure die-cast LM6 alloy housing offers excellent corrosion resistance and robustness, toughened and shatter proof quality built-in lens enhances safety with wide input voltage range 140-270V and inbuilt 4KV surge protection, long life of 50,000 Hrs. @ L70B50 with ambient temperature of 35 degree Celsius and luminous efficacy of 110Lm/W ,Color Temperature of 6500K,CRI70 and PF 0.95 with IP66 Protection and impact resistance of IK07 with electrical protection of Class I etc.The luminare shall have auto cut off and auto restart for under voltage and over voltage protection and phase to phase 440 V protection for 8 hours,Similar to PHILIPS – BRP062 LED 68 CW SLC S1 PSU GR or equivalent in Wipro/Jaquar

32

-

-

... More
Supply and installation of 20W LED integral type wide spread IP65 Floodlight with minimum lumen output of 1600 lumens with Aluminium housing and large honey comb light diffuser uniform and glare free light.Mechanical impact resistance of Ik-06,Class 1 protection with a life of 15000 burning hours @Ta 25 degree celcius,Operating voltage of 100-240V complies IEC 60598 Similar to PHILIPS : BVP132-LED16/WW 20W 100-240V WB IN or equivalent in Wipro/Jaquar

9

-

-

... More
Supply and Installation of integrated 12W COB spike light with Aluminium body with anthracite color. Similar to Philips make: Spike light- My Garden Spike 12W or equivalent in Wipro/Jaquar

54

-

-

... More
Supply Conveyance, installation, testing and commissioning of 35W LED Post top light with output greater than 100lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance in the existing pole/post. brSimilar to Wipro make LP06-351XXX-30-XX or equivalent in Philips/Jaquar

66

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 kV grade as required.4 X 6 sq.mm

8

-

-

... More
Supply and Providing maintenance-free Earthing system comprise of molecularly bonded copper of 99.9% purity on low carbon steel of 1250mm length and 14.2mm diameter. Copper bonding of 250 microns. High resistance to corrosion and high tensile strength. Copper bonded low carbon steel electrode complies to IS 3043 with connector having 250 microns. 5 Kg earth conductivity enhancing mineral compound tested as per IEC 62561 - 7. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 ohm m. It should be free from hazardous substances The mineral compound is required to have minimum 5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 320mmx 320mmx 190mm with a weight bearing capacity of 50KN. Make: Cape / OBO/Erico

4

-

-

... More
Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of 250 microns with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances. The mineral compound is required to have minimum 30 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs the Earth Rod. The dimension shall be 320mmx 320mmx 190mm with a weight bearing capacity of 50KN. Govt approved Indian labs test certificate required.

2

-

-

... More
Supplying and fixing of following sizes of Rigid PVC heavy-duty conduit along with accessories in gound including excavation up to 40cm, refilling and making good the damages.25 mm

1000

-

-

... More
Supply and fixing Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) - Outdoor Junction box of min 140mm x 140mm x 79mm dimensions with special terminals for mounting cables and 3 nos M25 IP 68 glands, Degree of Ingress Protection IP 65 or above in accordance with IEC 60529. The Junction Box shall have hinged door/cover. The Junction Box shall have pre punched / knock out for cable entry in all the four sides as well as on the back side. The Junction box shall be suitable to perform under ambient temperature for PS -25 degC up to +40 degC & PC -35 degC up to +80 degC & should be able to resist temperature up to +130 degC. The JB shall be halogen & silicon free. The PC thermoplastic JB shall be fire retardant & self extinguishing, the combustion behaviour shall be in accordance with VDE 0471 / UL 94 for 960degC. The Junction Box shall be UV resistance. The enclosures shall have the minimum dimensions as below. Make: Spelsberg/OBO/Hensel

120

-

-

... More
Supply and installation of Outdoor feeder piller consisting non-metallic enclosures for industrial use with an ingress protection of IP66 and strength IK 10 should be of light grey color made of fibreglass reinforced polyester with high impact resistance and outstanding performance in extreme environments should have 180 degree openable door with GRP hinges and color RAL 7035 according to IEC62208. The enclosure must be of double insulation, Halogen free with high impact resistance of IK10 according to IEC 62262.The material used should be self-extinguishing with working temperature from -25 degC to +120 DegC. This should have polycarbonate transparent cover for meter viewing. In case if flanges are used for connecting enclosures together, the interconnection also should offer similar Ingress protection or not less than IP54. Dielectric strength 5000 volts, insulation rating 5M . If metallic frames used outside the enclosure, it should be of Hot Dip Galvanized material with minimum thickness more than 2 mm. Incommer: 32A FP MCB 10kA - 1 No. 25A FP RCCB 30mA - 1 No.Astronomical Time switch - 1 No.Outgoing: 16A SP MCB 10kA - 12 Nos.Mounting Type: Floor mounting Minimum Dimension: 800x400x250 Make: CAPE Safybox/ Hensel

3

-

-

... More
Supply and Installation of 3 metre Hot dipped galvanised Octogonal pole in single section with 70mm top diameter, 130mm bottom diameter, 3mm sheet thickness, base plate dimensions of 200 x 200x 12 mm along with 16mm diameter (4 numbers) foundation bolts of 450mm bolt length, 200mm pitch circle diameter manufactured from special steel along with nuts, washers, anchor plate and common template.

66

-

-

... More
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

6

-

-

... More
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

13

-

-

... More
OPERATION AND MAINTENANCE

-

-

-

... More
Maintenance Charges for Horticulture for First Year

1

-

-

... More
Maintenance Charges for Horticulture for Second Year

1

-

-

... More
Maintenance Charges for Horticulture for Third Year

1

-

-

... More
Maintenance Charges for Horticulture for Fourth Year

1

-

-

... More
Maintenance Charges for Horticulture for Fifth Year

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.