Smart City Thiruvananthapuram Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Smart City Thiruvananthapuram Limited Tender
Electrical and Electronics
Eprocure
Opening Date19 Jan 2024
Closing DateCancelled
Tender Amount₹ 60,33,397
Costs
EMD
₹ 50,000Document Cost
₹ 3,252Tender Fee
Refer Documents
Summary
City Beautification Works -electrical Works For The Azhankal Walk Way Beautification
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SCTLT_646675_1Bid Award Id
ViewTender No
SCTL/TECH/2777/2024/AME/55Tender Authority
Smart City Thiruvananthapuram Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Instruction regarding make list
special condition for electrical work
BOQ Items
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
200
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
100
-
-
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
50
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
5
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
8
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
4
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
4
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
3
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
150
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
150
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
100
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
10
-
-
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
6
-
-
LT Cable End Terminations and Straight Joints
-
-
-
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1220
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 4 sq mm
350
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
2000
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm
350
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 25 sq mm
270
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm
1620
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm
330
-
-
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm
950
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
2
-
-
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.
20
-
-
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters
14
-
-
Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
5
-
-
Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
5
-
-
Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
12
-
-
Supplying and making outdoor end termination with cast resin compound including aluminiumlugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 185 sq. mm
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
20
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
8
-
-
Distribution Boards, Panels
-
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
2
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door
2
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
50
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
10
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2
-
-
Supply and Installation and Testing and Commissioning of Outdoor box with necessary accessories suitable for mounting 2/3 Module(Dimensions: 100 x 150 x 96 mm) MCBs with Transparent glass, with protection class IP65, 1 Row, 3 available modules, Rated operational voltage: 400V AC, Rated insulation voltage: 1000V AC, 1000V DC, metric knockouts on top and bottom for universal cable insertions with cable glands and/or double membrane seals, elastic entries double membrane seals M20 on top with PE/N terminal rail, each with 1 clamping point 16 mm² and 3 terminal points 6 mm² Accessories supplied: Double-membrane seals: 1x M25, sealing plugs, masking and labelling strips. Electrical characteristics: Rated operating voltage AC: 400 V, Rated insulation voltage AC: 1000 V, Protection class: II ,Type of protection: IP65. Material: Base unit material: Polycarbonate, Cover material: Polycarbonate, glass-fibre reinforced, Sealing material: Polyurethane, Cover screw material: Polyamide, glass-fibre reinforced, Hinged window material: Polycarbonate. Material characteristics: UV-resistant: yes, Halogen free: yes, Flammability class according with UL94: V2, Glow-wire flammability according to EN 60695-2-11: 960 °C. Mechanical properties: Type of fastening: Surface mounting, Impact strength: IK08, Sealable: yes, Cover screw torque: 1.2 Nm. Make : Spelsberg, Model no. AKi 03 or equivalent.
5
-
-
Supply and Installation and Testing and Commissioning of Outdoor box with necessary accessories
suitable for mounting 4 Module(Dimensions: 125 x 200 x 122 mm) MCBs with Transparent glass, with
protection class IP65, 1 Row, 5 available modules, Rated operational voltage: 400V AC, Rated insulation voltage: 1000V AC, 1000V DC, metric knockouts on top and bottom for universal cable insertions with cable glands and/or double membrane seals, elastic entries double membrane seals M20 on top, with PE/N terminal rail, each with 2 terminal points 16 mm² and 3 terminal points 6 mm² Accessories supplied: Double-membrane seals: 1x M25, sealing plugs, masking and labelling strips. Electrical characteristics:Rated operating voltage AC: 400 V, Rated insulation voltage AC: 1000 V, Protection class: II, Type of protection: IP65. Material: Base unit material: Polycarbonate, Cover material: Polycarbonate, glass-fibre reinforced, Sealing material: Polyurethane, Cover screw material: Polyamide, glass-fibre reinforced, Hinged window material: Polycarbonate. Material characteristics: UV-resistant: yes, Halogen free: yes, Flammability class according with UL94: V2, Glow-wire flammability according to EN 60695-2-11: 960 °C. Mechanical properties: Type of fastening: Surface mounting, Impact strength: IK08, Sealable: yes, Cover screw torque: 1.2 Nm. Make : Spelsberg, Model no. AKi 05 or equivalent.
5
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
2000
-
-
S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor
1
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
800
-
-
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm GI strip
100
-
-
Earthing with G.I. earth pipe 3 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
18
-
-
Supply and Installation and Testing and Commissioning of Main PANEL IP55 OUTDOOR: (FABRICATED OUT OF 16G CRCA SHEET) BUS BAR : 32 X 10 X 1 ALUMINIUM FOR PHASE & 32 X 6 X 1 ALUMINIUM FOR NEUTRAL, CABLE ENTRY : TOP / BOTTOM BASE : 75 X 40 X 40 C
CHANNEL EARTHING : 25 X 3 X 1 mm CU BUS EARTH INCOMER: 1 250A 4P 36KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER + NEUTRAL LINK 1 NOS, 250A FUSE BASE 3 NOS, 250A HRC FUSE 3 NOS, NEUTRAL LINK 1 NOS PROVISION FOR 3 PHASE ENERGY METER WITHOUT CT 1 NOS METERING: 1)2A SP MCB 6 NOS 2) LED INDICATION (R,Y,B) 1 SETS 3) VOLTMETER (0-500V) 1 NOS 4)VOLTMETER SELECTOR SWITCH 1 NOS 5) NEUTRAL LINK 1 NOS OUTGOING: 1) 100A 4P 25KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 2 NOS 2) 63A 4P 25KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 4 NOS
2
-
-
Supply and Installation and Testing and Commissioning of SUB PANEL-1 IP55 OUTDOOR:
(FABRICATED OUT OF 16G CRCA SHEET) BUS BAR : 25 X 6 X 1 ALUMINIUM FOR PHASE & 25 X 6 X 1 ALUMINIUM FOR NEUTRAL 2 NOS CABLE ENTRY : TOP / BOTTOM BASE : 75 X 40 X 40 C
CHANNEL EARTHING : 25 X 3 X 1 mm CU BUS EARTH INCOMER: 1 100A 4P 25KA THERMAL
MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 1 NOS METERING: 1) 2A SP MCB 6 NOS 2) LED INDICATION (R,Y,B) 1 SETS 3) VOLTMETER (0-500V) 1 NOS 4)VOLTMETER SELECTOR SWITCH 1 NOS 5) NEUTRAL LINK 1 NOS OUTGOING: 1) 63A TP MCB 2 NO, 2) 32A TP MCB 2 NOS 3) DIGITAL TIMER 2 NOS 4) 63A 4P POWER CONTACTOR 1 NOS 5) 32A 4P POWER CONTACTOR 1 NOS 6) ADDON BLOCK 2NO + 2NC 2 NOS 7)AUTO/MANUAL SELECTOR SWITCH 2 NOS 8) 25A DP MCB 1 NOS 9) 32A SP MCB 8 NOS
2
-
-
Supply and Installation and Testing and Commissioning of SUB PANEL-2 IP55 OUTDOOR:
(FABRICATED OUT OF 16G CRCA SHEET) BUS BAR : 25 X 6 X 1 ALUMINIUM FOR PHASE & 25 X 6 X 1 ALUMINIUM FOR NEUTRAL CABLE ENTRY : TOP / BOTTOM BASE : 75 X 40 X 40 C CHANNEL EARTHING : 25 X 3 X 1 mm CU BUS EARTH INCOMER: 1) 63A 4P 25KA THERMAL MAGNETIC BASED MCCB WITH 3OC, SC, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BAREEIER 1 NOS METERING: 1) 2A SP MCB 6 NOS 2) LED INDICATION (R,Y,B) 1 SETS 3) VOLTMETER (0-500V) 1 NOS 4) VOLTMETER SELECTOR SWITCH 1 NOS 5) NEUTRAL LINK 1 NOS OUTGOING: 1) 63A TP MCB 1 NOS 2) 32A TP MCB 2 NOS 3) DIGITAL TIMER 2 NOS 4) 63A 4P POWER CONTACTOR 1 NOS 5) 32A 4P POWER CONTACTOR 1 NOS 6) ADDON BLOCK 2NO + 2NC 2 NOS 7)AUTO/MANUAL SELECTOR SWITCH 2 NOS 8) 25A DP MCB 1 NOS 9) 32A SP MCB 8 NOS
7
-
-
Light Fittings
-
-
-
Supply and Installation and Testing and Commissioning of LED INVERTER STREET LIGHT 60W WITH RTC,Energy efficient 60W LED Street Light Technical Specifications: Housing Material: Aluminum PDC, Top maintainable Front Cover: Clear toughened glass Lens: Suitable high efficient secondary lens LED: LM80 certified LED LED Lumen Maintenance: 50,000 hours @ L70 Control Gear: Isolated, Electronic, CC driver RTC enabled Internal Wiring: Insulated Cu wire Hardware: SS & MS Zinc plated and passivated Ingress Protection: IP66 Impact Resistance: IK05 Operating Voltage: 140V~270V Operating Temperature: -10C~ 50C. Emergency time: 3 hours Min. (Battery Back-up with Li-ion Battery) Rated Voltage & Frequency 240V, 50Hz, System Wattage 60W±10%, System Current 289mA, Power Factor 0.95, System Lumen Efficacy, 100lm/W, CCT (As per ANSI) 5700K, CRI 70, THD 10%, Driver Efficiency 85%. Open & Short circuit protection, reverse polarity protection, high voltage cut off at 300V±10V and 5KV Internal Surge protection. Make : Halonix, Model : HLSLD-ML04-60-CWL-INV-RTC-R or Equivalent reputed brand make luminaire. with 5year warranty for luminaire and 3year for battery
62
-
-
Supply, Installation, Testing and commissioning of LED INVERTER STREET LIGHT 45w with rtc,energy efficient 60W LED Street Light Technical Specifications: Housing Material: Aluminum PDC, Topmaintainable Front Cover: Clear toughened glass Lens: Suitable high efficient secondary lens LED: LM80 certified LED LED Lumen Maintenance: 50,000 hours @ L70 Control Gear: Isolated, Electronic, CC driver RTC enabled Internal Wiring: Insulated Cu wire Hardware: SS & MS Zinc plated and passivated Ingress Protection: IP66 Impact Resistance: IK05 Operating Voltage: 140V~270V Operating Temperature: -10C~ 50C. Emergency time: 3 hours Min. (Battery Back-up with Li-ion Battery) Rated Voltage & Frequency 240V, 50Hz, System Wattage 60W±10%, System Current 289mA, Power Factor 0.95, System Lumen Efficacy, 100lm/W, CCT (As per ANSI) 5700K, CRI 70, THD 10%, Driver Efficiency 85%. Open & Short circuit protection, reverse polarity protection, high voltage cut off at 300V±10V and 5KV Internal Surge protection. Make : Halonix, Model : HLSLD-ML04-45-CWL-INV-RTC-R or Equivalent reputed brand make luminaire with Min 5year warranty for luminaire and 3year for battery
45
-
-
Supply, Installation, Testing and commissioning of LED 70W Street Light As per IS 10322 (Part-5/Sec-3) & IEC 60598-1 Technical Specifications: Main Housing / Heat Sink Material: Aluminium PDC Front Cover: Clear Poly Carbonate Lens: Suitable high efficient moulded lens LED: LM 79 & LM80 certified LED Lumen Maintenance: 50000 hours @ L70 Control Gear: Isolated, Electronic, CC Driver Internal Wiring: Insulated Cu wire Hardwares: SS & MS Zinc plated and passivated Ingress Protection: IP66 Impact Resistance: IK07 Operating Voltage Range: 140V~ 270V Operating Temperature: -10C~ 50C. Rated Voltage & Frequency 240V, 50Hz, System Wattage 70W±10%, System Current 338mA, Power Factor 0.95, System Lumen Efficacy, 105lm/W, CCT (As per ANSI) 6500K, CRI 70, THD 10%, Driver Efficiency 85%. Make: Halonix, Model: HLSLD-01-70-CWDL-R-SH-SPD or equivalent reputed make with 5 year luminaire warranty
61
-
-
Supply, Installation, Testing and commissioning of LED 45W Street Light As per IS 10322 (Part-5/Sec-3) & IEC 60598-1 Technical Specifications: Main Housing / Heat Sink Material: Aluminium PDC Front Cover: Clear Poly Carbonate Lens: Suitable high efficient moulded lens LED: LM80 certified LED Lumen Maintenance: 50000 hours @ L70 Control Gear: Isolated, Electronic, CC Driver Internal Wiring: Insulated Cu wire Hardwares: SS & MS Zinc plated and passivated Ingress Protection: IP66 Impact Resistance: IK07 Operating Voltage Range: 140V~ 270V Operating Temperature: -10C~ 50C. Rated Voltage & Frequency 240V, 50Hz, System Wattage 70W±10%, System Current 338mA, Power Factor 0.95, System Lumen Efficacy, 105lm/W, CCT (As per ANSI) 6500K, CRI 70, THD 10%, Driver Efficiency 85%. Make : Halonix, Model:HLSLD-15-45-CWL-R-HL2-P or euivalent reputed make with min 5years warranty
45
-
-
Supply, Installation, Testing and commissioning of 6A SP MCB, 32A Neutral link along with 32A 4P connectors with necessary accessories for fixing inside Street light pole
123
-
-
Evaluation Notes How It Works ?