Smart City Thiruvananthapuram Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Smart City Thiruvananthapuram Limited Tender
Energy, Oil and Gas
Eprocure
Opening Date3 May 2023
Closing Date30 May 2023
Tender Amount₹ 56,27,403
Costs
EMD
₹ 50,000Document Cost
₹ 3,250Tender Fee
Refer Documents
Summary
Epc Mode Contract For Erection, Testing And Commissioning Of Grid Tied Rooftop Spv
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_SCTLT_574626_1Bid Award Id
ViewTender No
SCTL/PRJ/232/2023/ Solar/02Tender Authority
Smart City Thiruvananthapuram Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for second year
40
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for third year
40
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for fourth year
40
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for fifth year
40
-
-
AR CAMP, NANDAVANAM, TRIVANDRUM
-
-
-
Supply, Installation,Testing and commissioning of ongrid Solar Photovoltaic Power plant confirming to MNRE specifications, consisting of Mono Perc half cut crystalline silicon solar cells, net metering facility, neccessary protections, earthing, mounted on Aluminium Alloy structure of adequate strength with following components complete as required :- a) Solar Photovoltaic Module of reputed manufacture with capacity of 550 Wp or above , manufactured in india, comfirming to IS 14286/IEC 61215, IS/IEC 61730- Part -1, IS/IEC 61730- Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 20%. b) Power Conditioning Unit (PCU) of 200-1000 V DC Input Voltage range and output 400V AC, three phase,4 wire,50 Hz suitable to generate AC power with efficency not less than 98%,with standard IEC conditions, suitable for ambient temprature from 0 to 50 degree C. c) Essential Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands,lugs and other accessories etc. as required.
e)Lightning and surge voltage protection.
f) Connections and interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, mian power cable to grid supply PCU along with supplying & fixing of neccessary channel / conduit lugs and other accessories etc. as required. g) BoS as applicable if any. h)Integrating system as per Engineer In Charge
i)Earthing of the plant as per standard IEC 60364/IS 3043 (1987) where neccessary.
20
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for first year
20
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for second year
20
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for third year
20
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for fourth year
20
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for fifth year
20
-
-
MLCP, THAMPANOOR, TRIVANDRUM
-
-
-
Supply, Installation,Testing and commissioning of ongrid Solar Photovoltaic Power plant confirming to MNRE specifications, consisting of Mono Perc half cut crystalline silicon solar cells, net metering facility, neccessary protections, earthing, mounted on Aluminium Alloy structure of adequate strength with following components complete as required :- a) Solar Photovoltaic Module of reputed manufacture with capacity of 550 Wp or above , manufactured in india, comfirming to IS 14286/IEC 61215, IS/IEC 61730- Part -1, IS/IEC 61730- Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 21%. b) Power Conditioning Unit (PCU) of 200-1000 V DC Input Voltage range and output 400V AC, three phase,4 wire,50 Hz suitable to generate AC power with efficency not less than 98%,with standard IEC conditions, suitable for ambient temprature from 0 to 50 degree C. c) Essential Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands,lugs and other accessories etc. as required.
e)Lightning and surge voltage protection .
f) Connections and interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, mian power cable to grid supply PCU along with supplying & fixing of neccessary channel / conduit lugs and other accessories etc. as required. g) BoS as applicable if any. h)Integrating system as per Engineer In Charge
i)Earthing of the plant as per standard IEC 60364/IS 3043 (1987) where neccessary.
35
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for first year
35
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for second year
35
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for third year
35
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for fourth year
35
-
-
Operation & maintenance including cost of replacement of all parts after sucessful commissioning of Roof top Solar PV system as per the scope of work & technical specifications under O&M to be quoted for fifth year
35
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements