Regional Cancer Center Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Regional Cancer Center - RCC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Nov 2024
Closing Date23 Nov 2024
Tender Amount₹ 59,82,756
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RCC_703450_1Tender No
RCC/ENG-M/2024-25/E-101Tender Authority
Regional Cancer Center ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Installation, testing & commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 40 mm thick sandwitched panels with polyurethane foam (PUF) insulation, complete with Plug type fan, VFD driven electric motor, coil section, filter section, drain pan, VFD etc. The Cooling coil is of copper tubes (tubes thickness not less than 0.5 mm) and aluminium fins (min. 10fins per inch) of 6 rows deep. Filter section with 50 mm thick metal viscous/washable synthetic type air pre-filters efficiency 80% down to 10 micron. TEFC sq. cage induction motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply including mounting and fixing arrangements, IE3 Motor Plug fan with VFD Drives anti vibration springs/isolator bearings etc., drain connections, stainless steel (18G) drain pan with PUF insulation. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Limit switch in door and inspection lamps to be fixed. Insulation of all section with fire retardant insulation material as per manufacture’s standard. Air vent on cooling coil with globe valve/screwed plugs. 150 mm dia. dial type pressure gauges (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, Control wiring to make M/V in close position while AHU is OFF with relays, necessary vibration isolation arrangement etc.brVFD and control panel all to form the integral part of AHU and to be supplied by the AHU manufacture itself. VFD driven AHU with plug fans and VFD starter panel / controller with all necessary connections with pressure / Temperature sensors (minimum 2 nos.) required to control the VFD Speed. Power & Control wiring from VFD to AHU to be included. Only HVAC application VFD's shall be used. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi [Total Harmonic Distortion Current] below 5%, auto bypass starter compactable to the third party BMS.brAll AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost etc. complete as per specification including all accessories as specified and as required. and of following capacities.brExternal Static Pressure for AHU's with fine filters is 50 MM Static
-
-
-
... More
15 TR, 6000cfm
1
-
-
... More
20 TR, 8000cfm
2
-
-
... More
30 TR, 12000cfm
3
-
-
... More
Supply, Installation, testing & commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 46 mm thick sandwitched panels with polyurethane foam (PUF) insulation, complete with Plug type fan, VFD driven electric motor, coil section, mixing box, filter section, drain pan, Heater banks, VFD etc. The Cooling coil is of copper tubes (tubes thickness not less than 0.5 mm) and aluminium fins (min. 10fins per inch) of 6 rows deep. Mixing box with Aluminium Aerofoil SA,RA damper, Al Aerofoil fresh air damper with fresh air, filter section with prefilters and micro filters, Prefilter with efficiency 80% down to 20 micron, fine filter section with efficiency 95% down to 5 micron. TEFC sq. cage induction motor suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply including mounting and fixing arrangements, IE3 Motor Plug fan with VFD Drives anti vibration springs/isolator bearings etc., drain connections, stainless steel (18G) drain pan with PUF insulation. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Limit switch in door and inspection lamps to be fixed. Insulation of all section with fire retardant insulation material as per manufacture’s standard. Air vent on cooling coil with globe valve/screwed plugs. 150 mm dia. dial type pressure gauges (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, Control wiring to make M/V in close position while AHU is OFF with relays, necessary vibration isolation arrangement etc.brHeater bank coming along with AHU‘S should comprise of thermostat, humidistat, safety thermostat, contactors, Controls & control Wiring etc. rate to be included in the AHU costing itself. Also all the AHU should have space to accommodate heater banks, heater capacity 3 x 2 KW, Thermal breakbrVFD and control panel all to form the integral part of AHU and to be supplied by the AHU manufacture itself. VFD driven AHU with plug fans and VFD starter panel / controller with all necessary connections with pressure / Temperature sensors (minimum 2 nos.) required to control the VFD Speed. Power & Control wiring from VFD to AHU to be included. Only HVAC application VFD's shall be used. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi [Total Harmonic Distortion Current] below 5%, auto bypass starter compactable to the third party BMS.brAll AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost etc. complete as per specification including all accessories as specified and as required. and of following capacities.brExternal Static Pressure for AHU's with fine filters is 55 MM Staticbr10 TR 4000cfm
-
-
-
... More
10 TR 4000cfm
1
-
-
... More
15 TR 6000cfm
1
-
-
... More
Chilled water line
-
-
-
... More
Site fabricated pipe with PUF insulation & GI cladding for pipe AHU room area & valve insulation with openable boxing for inspection. The Pipes of sizes 150mm & below shall be M.S. ‘C’class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above
-
-
-
... More
80mm dia. (50mm thick insulation)
1
-
-
... More
65mm dia. (50mm thick insulation)
1
-
-
... More
50mm dia. (50mm thick insulation)
1
-
-
... More
40mm dia. (50mm thick insulation)
100
-
-
... More
32mm dia. (50mm thick insulation)
80
-
-
... More
25mm dia. (50mm thick insulation)
25
-
-
... More
Cooling Thermostat
-
-
-
... More
Supply, installation, testing and commissioning of cooling thermostat shall be electronic room temperature controller with digital display temp & fan speed control, capable of providing individual space temperature control for cooling application. The controller shall produce a dual output to cooling coils in response to load change in rooms.
-
-
-
... More
Thermostat for AHUs
7
-
-
... More
Drain Piping
-
-
-
... More
Supply and fixing in position of condensate drain water & indoor unit drain to the floor trap PVC piping with 9mm thick nitrile rubber insulation and with necessary fittings like elbows, tees and reducers etc. Openings as good as same
-
-
-
... More
40 mm dia
40
-
-
... More
32 mm dia
40
-
-
... More
25 mm dia
10
-
-
... More
Valves
-
-
-
... More
Butterfly Valves
-
-
-
... More
Supplying, fixing, testing and commissioning of following butterfly valve in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water circulation as specified.
-
-
-
... More
80 mm dia
1
-
-
... More
65 mm dia
1
-
-
... More
50 mm dia
1
-
-
... More
40 mm dia
10
-
-
... More
32 mm dia
8
-
-
... More
Ball Valves
-
-
-
... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
.
-
-
-
... More
25 mm dia
8
-
-
... More
20 mm dia
1
-
-
... More
Y-strainer
-
-
-
... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified
-
-
-
... More
40 mm dia
5
-
-
... More
32 mm dia
3
-
-
... More
25 mm dia
1
-
-
... More
Pressure Gauge
-
-
-
... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
.
-
-
-
... More
Temperature gauge
-
-
-
... More
Providing & fixing in position the mercury in glass industrial type thermometers.
-
-
-
... More
Auto Air vent including Ball Valves
-
-
-
... More
Supply & install of airvents / purge valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required.
-
-
-
... More
Pressure independent cum balancing Valves
-
-
-
... More
Supply, Installation, Testing and Commissioning of following sizes electronic, selfbalancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.
-
-
-
... More
40 mm DIA
5
-
-
... More
32 mm DIA
3
-
-
... More
25 mm DIA
1
-
-
... More
Ducting, Grills, Diffusers and Insulation
-
-
-
... More
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006
-
-
-
... More
Thickness 0.63 mm sheet
1
-
-
... More
Thickness 0.80 mm sheet
1
-
-
... More
Thickness 1.00 mm sheet
10
-
-
... More
Thickness 1.25 mm sheet
10
-
-
... More
Grills and Diffusers
-
-
-
... More
Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
GI volume control duct damper
1
-
-
... More
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper
1
-
-
... More
Factory made fresh air dampers with louvers and control lever.
1
-
-
... More
Underdeck Insulation
-
-
-
... More
supply & fixing of 12 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
160
-
-
... More
Acoustic Insulation
-
-
-
... More
Supply & fixing of acoustic lining 15 mm thick with insulation with adhesive as per the recommendation of the manufacture with density 140-180kg/m3
300
-
-
... More
Duct Insulation
-
-
-
... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm thickness
20
-
-
... More
Supply & fixing of 10 mm thick class O acoustic nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 140-180kg/m3
10
-
-
... More
Electrical Work
-
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
180
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
120
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 16 sq. mm + 2 X 6 sq. mm earth wire
150
-
-
... More
Buy back AHU
-
-
-
... More
Buy back value for the following existing old AHUs, chilled water piping and accessories including dismantling and other labour charges. brNote: The equipments and connected piping to be disconnected from the live system without affecting air-conditioning in other areas. It should be carried out at the own risk of the contractorbr10 TR floor mounted AHUs with connected piping and accessories-01 nos.
1
-
-
... More
Buy back value for the following existing old AHUs, chilled water piping and accessories including dismantling and other labour charges. brNote: The equipments and connected piping to be disconnected from the live system without affecting air-conditioning in other areas. It should be carried out at the own risk of the contractorbr15 TR floor mounted AHUs with connected piping and accessories-01 nos
4
-
-
... More
Buy back value for the following existing old AHUs, chilled water piping and accessories including dismantling and other labour charges. brNote: The equipments and connected piping to be disconnected from the live system without affecting air-conditioning in other areas. It should be carried out at the own risk of the contractorbr20 TR floor mounted AHUs with connected piping and accessories-01 nos.
2
-
-
... More
Buy back value for the following existing old AHUs, chilled water piping and accessories including dismantling and other labour charges. brNote: The equipments and connected piping to be disconnected from the live system without affecting air-conditioning in other areas. It should be carried out at the own risk of the contractorbr30 TR floor mounted AHUs with connected piping and accessories-01 nos.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements