Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Jan 2025
Closing Date6 Feb 2025
Tender Amount₹ 2,68,434
Costs
EMD
₹ 6,711Document Cost
₹ 595Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWD_731291_1Tender No
PWD/BLDG/TR/14724/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://keralapwd.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
OD110839/2024-2025:Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
9
-
-
... More
1.47:Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
27
-
-
... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
9
-
-
... More
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
3
-
-
... More
OD110840/2024-2025: Supply and providing the following types and power rated lamps in the existing fittings as required.B22 LED bulb 9W
3
-
-
... More
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
3
-
-
... More
OD110842/2024-2025:Supply and installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.<br>300 / 305 mm sweep light duty exhaust fan in metal frame.
3
-
-
... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
3
-
-
... More
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
3
-
-
... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
9
-
-
... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
9
-
-
... More
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1
-
-
... More
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
3
-
-
... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
102
-
-
... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
10
-
-
... More
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
50
-
-
... More
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
90
-
-
... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
187
-
-
... More
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
1
-
-
... More
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2
-
-
... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
12
-
-
... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
4
-
-
... More
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
3
-
-
... More
OD219016/2024-2025:OD206532/2024-2025 SITC of 1 phases in and 1 phase out 2 kVA, without isolation transformer type, online UPS having 60 minute backup, connecting in stand-alone configuration with the following specification. a) input PF: 0.99 @ full load b) output PF: 0.95 or above c) input voltage range: 140V- 280V with cutoff d) THD: <=10% , e) overall efficiency:>=85%, f) ambient temperature : 0° C to 40° C, g) generator compatibility, h) pure sine wave, i) battery over charge & under charge cut off, j) bypass arrangement, k) EN/IEC 620401 for General Safety compatibility l) EN/IEC 620402 for Electromagnetic Compatibility m) EN/IEC 620403 for Performance n) EN/IEC 620404 or equal for Environmental compatibility o) LED+LCD Display p) Approved UPS make : Riello/APC/Fuji/Delta/Numeric q) Approved c10 rated tubular Battery make: 12V,42Ah or higher C10 rated Exide/Amaron Quanta/Panasonic r) Architecture; Tower type( rack mountable not acceptable ) s) Marking: CE, BIS, RoHS t) All certificate copy to be submitted u) Warranty: 3 year after SITC.
1
-
-
Evaluation Notes How It Works ?
Potential Partner