Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 3,140Document Cost
₹ 555Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_682025_1Bid Award Id
ViewTender No
PWD/BLDG/TR/8043/2023_6_1_1/1Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://www.keralapwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
1
105
105.18
OD19893/2023-2024:Supply and providing the 9W LED lamp in the existing fittings as required
1
128
128.77
OD19894/2023-2024:Supply and fixing of 10W LED bulk head fittings IP65 die cast aluminum Poly carbonate front cover directly on wall including drilling necessary holes, giving connections with required length of 16/0.20mm 3 core copper conductor flux wire conforming to relevant ISS or extending the original wiring making good the damages, colour washing etc are required. (Philips/Bajaj/Havells/Wipro)
1
950
950.1
OD19877/2023-2024: Supply, Conveyance, Installation, Testing and commissioning of 3Phase, 415V, 5HP/3.7KW, 50Hz,Vertical Open Well submersible pump set confirming to IS capable to discharge a total head of 37-114 mtr , 27000-7200 LPH, with out let 63mm sizer as per IS specification as required.[ Aquatex/KSB /Kirloskar/Texmo ] Model No: AVRS 40/16 To 20(Aquatex).
1
38171
38171.95
90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL)
1
4054
4054.59
90.14.24.17:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
1
544
544.35
OD19878/2023-2024:Supply and Installation 63mm PVC Pipe( ISI).
2
479
239.68
OD19879/2023-2024:Supply and Installation 63mm MTA PVC(ISI)
2
288
144.44
OD19880/2023-2024:Supply and Installation of 63mm HD Hose clip ss
4
633
158.38
OD19881/2023-2024:Supply and Installation of 63mm HDPE ISI 6kg/cm2 pipe (Jain make LMR)
12
796
66.39
OD19882/2023-2024:Supply and Installation of 63mm Ball Valve Appax Din
1
594
594.9
OD19883/2023-2024:SUpply and application of solvent cement
100
160
1.6
OD19884/2023-2024:Supply and Installation of 63mm PVC TEE
1
202
202.31
OD19885/2023-2024:Supply and Installation of 63mm SS Hose coller LMR
2
818
409.06
OD19886/2023-2024: Supply and Installation of 63mmx1Feet G.I.Barrel nipple
1
794
794.88
OD19887/2023-2024:Supply and Installation of 63mm GI Flange set [LMR]
1
520
520.77
OD19888/2023-2024: Supply and Installation of 63mm non return valve(LMR)
1
1720
1720.06
OD19889/2023-2024:Supply and Installation of 63mm GI Socket (ISI)
3
677
225.75
OD19890/2023-2024:Supply and Installation of 63mm GI Bend (ISI)
1
591
591.42
OD19891/2023-2024:Supply and Installation 63mm Union GI (ISI)
1
264
264.35
OD19892/2023-2024: Supply and laying of 20mm or nearest size Nylon rope
18
669
37.17
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
16
2136
133.5
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
10
2576
257.6
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
5
681
136.31
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
10
630
63.01
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
15
1461
97.42
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
15
1582
105.47
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1
99
99.55
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1
129
129.47
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
6550
6550.78
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1
232
232.66
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
1
963
963.63
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
970
970.67
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
3063
3063.1
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
6
57
9.59
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
2
5053
2526.54
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
25
4107
164.3
OD19895/2023-2024:Supply and Installation of current Sensing Phase Failure & UV+OV relay with Dry run & Over load Protection (Delayed Auto reset, 2 CO Contact) on DIN rail (model:Minilec D2 MPR2).
1
3006
3006.73
OD19896/2023-2024:Supply and fixing of Multi function meter to read:W, Wh or VA, Vah or V AR, V ARh or PF - 3 phase accuracy class 1 LED
1
4885
4885.92
OD19897/2023-2024:Providing and fixing Blue colour LED indicator, AC/DC, 22.5 mm cut out dia in existing panel and giving connection complete
1
133
133.54
OD19898/2023-2024:Providing and fixing Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia in existing panel and giving connection complete
2
198
99.17
OD19899/2023-2024:25 mm Corrugated PVC flexible conduit
5
245
49.04
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
14503
7251.6
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
35
2210
63.15
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
4
98
24.66
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
6
159
26.54
OD19900/2023-2024:Supply and providing 12x3mm brass nut and bolt etc are required
4
80
20.16
OD19901/2023-2024:Supply and providing 25x3mm brass nut and bolt etc are required
6
132
22.12
OD22711/2023-2024:Supply and fixing 63 A , 415V , AC 23A , TPN SDF with HRC fuse links in SS Enclosure:with front handle on wall or on existing angle iron framework , giving connections, etc. as required.
1
5886
5886.69
OD22710/2023-2024:Supplying and fixing 63, HRC Fuse with HRC Fuse link with connections, in existing meter board
3
1094
364.77
OD22709/2023-2024:S & F 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base. in the existing meter board and giving connections etc
1
278
278.76
OD19905/2023-2024:Supply & installation of dust and vermin proof, 3 Phase Syntex Meter Board( GS-MB-6535) and to fix KSEB LT meters, TVM with CTs/DHD and fuse cut out etc as required including fixing it on wall, making good the damages colour washing etc. as required. 650*350*250mm
1
6129
6129.15
OD19906/2023-2024:Supply and providing M8 anchor bolt hook in wall/parapet for binding support for service main
1
96
96.93
OD25973/2023-2024: Labour charges for dismantling the existing submersible pumpset from the openwell and damaged panel board after disconnection of electric connection.
0.5
603
1207.5