Public Works Department Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Nov 2024
Closing Date14 Nov 2024
Tender Amount₹ 26,32,582 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell

2

-

-

... More
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

12

-

-

... More
OD234178/2023-2024:Supply and providing the following types and power rated lamps in the existing fittings as required. LED bulb 7W/9W

20

-

-

... More
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.

15

-

-

... More
OD127445/2024-2025:Supply & providing LED Glass tube, 1200mm, 20w, 2000 lumen with internal diffused coating providing 320° light output in place of fused ones. (Havells make ST81213SSTL20WLED86S/ Philips make 20w865/ Crompton make LGT8-20-865-2-DS/ reputed make having similar properties

50

-

-

... More
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply

20

-

-

... More
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

5

-

-

... More
OD31415/2024-2025:Supplying and fixing two module piano type stepped electronic fan regulator on the existing switch box including connections.

20

-

-

... More
OD234180/2023-2024:Supply and renewing fan condenser of ceiling fan in place of faulty one and giving connection.

50

-

-

... More
OD31222/2024-2025:Charges for relocating existing Ceiling fan complete with down rod, 16/0.2 mm 3 core round copper conductor flex wire, providing new rubber shackle and all accessories in the ceiling.

18

-

-

... More
OD234182/2023-2024:Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.

8

-

-

... More
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.

2

-

-

... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

5

-

-

... More
OD127488/2024-2025:Supply, conveyance, installation, testing and fixing of 200W LED Flood light Driver with IP 67 protection with power factor greater than 0.90 at full load and Aluminium pressure die-cast housing in existing high mast pole by drawing down the motorized round arm , Inventronics make EAM-200S150SB/ equivalent reputed make having similar properties.

6

-

-

... More
OD32065/2024-2025:Supply, conveyance, installation, testing and commissioning of 70W LED Flood light Driver with IP 67 protection with power factor greater than 0.90 at full load and Aluminium pressure die-cast housing, Crompton/ Philips/Osram make

2

-

-

... More
90.15.4.10:Supply Conveyance, installation, testing and commissioning of 180W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

6

-

-

... More
90.15.2.3:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters

1

-

-

... More
90.15.3.1:Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters

3

-

-

... More
OD32455/2024-2025:Providing of Hot dip galvanized G.I. Ring Type Bracket for Light Fittings suitable for 3M to 10M octagonal poles after dismantling the existing single arm bracket.

7

-

-

... More
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor

1

-

-

... More
90.14.28.7:S & F Motor starters of the following ratingsFully automatic star delta starter for 25HP motor

2

-

-

... More
OD129533/2024-2025:Supply and installation of Siren for calling security staff during emergency situation. MS-190 Industrial Motor Siren 220V.

2

-

-

... More
OD129534/2024-2025:Supply, conveyance and installation of Programmable 24Hrs Analog Timer switch for performing automatic ON-OFF function. L&T make/ equivalent reputed make.

3

-

-

... More
OD128416/2024-2025:Supply, conveyance, installation, testing and commissioning of 230 V, 50 Hz, 2 HP Centrifugal Monoblock pump set, 50mm suction & 40mm delivery with average discharge of 6.3 to 3.6 LPS at a head of 12 to 25 meters. Kirloskar make KDS 225, Single Phase 2HP Monoblock Pump Set with standard accessories and giving connections etc. as required.

1

-

-

... More
OD31385/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 75AH Tubular battery with 3 years comprehensive warranty - Exide make EL75 and giving interconnections with 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.

3

-

-

... More
OD84304/2024-2025: Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade: One or more coats on old work

30

-

-

... More
OD84628/2024-2025: Painting with Red oxide primer of approved brand and manufacturer. One or more coats on old work.

15

-

-

... More
OD85023/2024-2025:Removing old painting by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

30

-

-

... More
OD87931/2024-2025:Supply and installation of FP enclosure for independent mounting of MCB/ RCCB/ RCBO/ isolator with 40A 4P isolator

3

-

-

... More
OD87951/2024-2025:Supply and fixing LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia (Red, Green, Black, Yellow, Orange colours )

26

-

-

... More
OD87959/2024-2025:Supply and fixing LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia (Blue colour )

10

-

-

... More
OD31423/2024-2025:Supply and fixing 16 Sq. mm Terminal Block in the existing panel assembly and giving connections. ( Connectwell CTS16U 76 Amp/ equivalent reputed make having similar properties.)

40

-

-

... More
OD141240/2024-2025:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required

240

-

-

... More
OD141247/2024-2025: Supply, conveyance installation testing and commissioning the light fittings made of CRCA sheet with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PV round block , giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. including providing 1200 mm 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted )

5

-

-

... More
OD141271/2024-2025: Supply, conveyance installation testing and commissioning the light fittings made of CRCA sheet with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. including providing 1200 mm 2 x 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted )

5

-

-

... More
OD141300/2024-2025: Supply, conveyance, installation, testing and commissioning the light fittings made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. including providing 1200 mm 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted )

5

-

-

... More
OD141302/2024-2025: Supply, Conveyance, installation, testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19 mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required. including providing 1200 mm 20 W T8 LED tube , having total efficiency of 100 Lumen /watt with 4 feet Aluminium extrusion in the tube for better heat dissipation,, THD < 20% PF> 0.95 ( LM 79 & LM 80 Certificate from NABL should be submitted )

5

-

-

... More
OD31336/2024-2025:Supply, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories with LED lamps suspended from ceiling using 4 nos steel chain (16 SWG or nearest available size) properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS. Recess mounting type LED panel Rectangular fitting, 33 Watts, 1'X4' size. ( Jaquar/ Philips/ Crompton/ Osram make )

3

-

-

... More
OD31337/2024-2025:Supply, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories with LED lamps suspended from ceiling using 4 nos steel chain (16 SWG or nearest available size) properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS. Recess mounting type LED panel Square fitting, 36 Watts, 2'X2' size. (( Jaquar/ Philips/ Crompton/ Osram make )

3

-

-

... More
OD31338/2024-2025:Supply, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories with LED lamps and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS. Recess mounting type LED panel Square fitting, 18 Watts, 1'X1' size. ( Jaquar/ Philips/ Crompton/ Osram make )

3

-

-

... More
OD31339/2024-2025:Supply, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories with LED lamps and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS. Recess mounting type LED panel Square fitting, 24 Watts, 1'X1' size. ( Jaquar/ Philips/ Crompton/ Osram make )

5

-

-

... More
OD31340/2024-2025:Supply, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories with LED lamps and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS. Recess mounting type LED panel Round fitting, 15 Watts, ( Jaquar/ Philips/ Crompton/ Osram make )

6

-

-

... More
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

4

-

-

... More
90.15.4.4:Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

1

-

-

... More
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

3

-

-

... More
90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

2

-

-

... More
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

4

-

-

... More
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

1

-

-

... More
OD128564/2024-2025:Supply, installation, testing and commissioning of Dehumidifier having an extraction capacity of 60litres/day, working temperature range 5 to 37 degree celsius, programmable timer, humidity setting and auto restart function. Origin Novita make ND60 Dehumidifier

1

-

-

... More
OD234184/2023-2024:Supply, Conveyance, Installation, testing and commissioning of wall mounting fan using mounting brackets supplied along with the fan (450mm sweep, Full metal construction, Orient make- Tornardo wall II - High Flow wall fan)/ Other equivalent make

4

-

-

... More
OD36588/2024-2025:Charges for checking the specific gravity of battery, cleaning the terminals, applying petroleum jelly in the terminals and making the same in good working condition.

3

-

-

... More
OD36591/2024-2025:Supply and filling distilled water in the existing battery.

300

-

-

... More
OD89078/2024-2025:Charges for detaching the 3HP,3 phase, pulley type AHU motor into stator and rotor, removing the whole burnt stator coils by cutting and pulling, cleaning and insulating the slots, rewinding the stator using original gauge super enameled copper winding wire and insulating materials, taping and varnishing the windings with best quality insulation varnish, baking the coils, painting of motor , assembling, testing etc. including conveyance to the works. (less cost of copper scrap wire dismantled)

1

-

-

... More
OD89079/2024-2025:Charges for detaching the 5HP,3 phase, pulley type AHU motor into stator and rotor, removing the whole burnt stator coils by cutting and pulling, cleaning and insulating the slots, rewinding the stator using original gauge super enameled copper winding wire and insulating materials, taping and varnishing the windings with best quality insulation varnish, baking the coils, painting of motor , assembling, testing etc. including conveyance to the works. (less cost of copper scrap wire dismantled)

1

-

-

... More
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

3

-

-

... More
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

4

-

-

... More
OD234185/2023-2024:Supply, Conveyance, Installation, testing and commissioning of 300mm sweep, 1400rpm, Heavy duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make

5

-

-

... More
OD234186/2023-2024:Supply, Conveyance, Installation, testing and commissioning of 450mm sweep, 1400rpm, Heavy duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make

2

-

-

... More
OD234187/2023-2024:Supply, Conveyance, Installation, testing and commissioning of 380mm sweep, 1400rpm, Heavy duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make

2

-

-

... More
OD234188/2023-2024:Supply, Conveyance, Installation, testing and commissioning of 225mm sweep, 1400rpm, Medium duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make

4

-

-

... More
OD32332/2024-2025:Supply, conveyance, installation, testing and commissioning of 250mm sweep, 2500 RPM, Round metal casing axial flow fan working on 230V A/C and fixing with necessary anchor bolts, nuts etc. as required. Eyyani make.

2

-

-

... More
OD32333/2024-2025:Supply, conveyance, installation, testing and commissioning of 300mm sweep, 2500 RPM, Round metal casing axial flow fan working on 230V A/C and fixing with necessary anchor bolts, nuts etc. as required. Eyyani make.

1

-

-

... More
OD128606/2024-2025:Supply of 10KVA, 3 Phase Input & 1 Phase Output Online UPS in standalone configuration with built in isolation transformer, PF 0.9, overload capacity 110% for 10minutes, output voltage regulation +/-1% for 100% unbalanced load. (Make Hykon /Numeric make)

2

-

-

... More
OD32280/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 26AH SMF battery - Exide make Powersafe Plus EP 26-12V SMF Battery and giving interconnections with 6 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.

40

-

-

... More
OD32310/2024-2025:Supply and installation of Battery rack made of G.I duly painted suitable for keeping 20nos of 26 AH SMF Battery.

2

-

-

... More
OD128703/2024-2025:Supply, conveyance, installation, testing and commissioning of 3KVA Online UPS with inbuilt 8 nos. of 7AH SMF batteries - Hykon make. HT1103LS/96V

1

-

-

... More
OD130209/2024-2025:Supply of 20KVA 3 Phase Input & 3 Phase Output Online Double Conversion DSP based UPS in standalone configuration with built in isolation transformer PF 0.9, overload capacity 110% for 10minutes, output voltage regulation +/-1% for 100% unbalanced load with 3 years comprehensive warranty. (Make EATON 93 UPS /Numeric make)

1

-

-

... More
OD130211/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 65AH SMF battery - Exide make Powersafe Plus EP 65-12V SMF Battery and giving interconnections with 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.

40

-

-

... More
OD32309/2024-2025:Supply and installation of Suitable size Battery rack made of G.I duly painted suitable for keeping 40nos of 65 AH SMF Battery.

1

-

-

... More
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm

180

-

-

... More
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm

15

-

-

... More
90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm

30

-

-

... More
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm

26

-

-

... More
90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm

15

-

-

... More
90.6.5.14:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 6.00 sq mm

10

-

-

... More
OD36662/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 120AH Tubular battery with 3 years comprehensive warranty - Exide make Inva master/EI master and giving interconnections with 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.

5

-

-

... More
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm

15

-

-

... More
1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm

10

-

-

... More
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm

20

-

-

... More
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm

30

-

-

... More
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm

25

-

-

... More
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm

53

-

-

... More
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm

40

-

-

... More
1.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch

78

-

-

... More
1.23.2:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.2 way 5/6 amps switch

4

-

-

... More
1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch

12

-

-

... More
1.23.4:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet

18

-

-

... More
1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet

10

-

-

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

88

-

-

... More
1.24.2:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

2

-

-

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

30

-

-

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

110

-

-

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

60

-

-

... More
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

15

-

-

... More
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator

5

-

-

... More
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket

5

-

-

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

10

-

-

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

15

-

-

... More
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

3

-

-

... More
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

2

-

-

... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

15

-

-

... More
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)

2

-

-

... More
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

20

-

-

... More
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

26

-

-

... More
1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module

10

-

-

... More
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

22

-

-

... More
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

30

-

-

... More
1.28.6:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module

4

-

-

... More
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface

20

-

-

... More
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface

26

-

-

... More
90.10.1.4:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )4 module moulded plastic box on surface

10

-

-

... More
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface

22

-

-

... More
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface

30

-

-

... More
OD234195/2023-2024: Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 12 module moulded plastic box on surface

4

-

-

... More
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp

20

-

-

... More
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp

10

-

-

... More
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

20

-

-

... More
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

15

-

-

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

15

-

-

... More
OD88950/2024-2025:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip

20

-

-

... More
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm

10

-

-

... More
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm

5

-

-

... More
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size

15

-

-

... More
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

6

-

-

... More
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

4

-

-

... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

6

-

-

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

1

-

-

... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

... More
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

48

-

-

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

3

-

-

... More
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

3

-

-

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

5

-

-

... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

3

-

-

... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

3

-

-

... More
2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps

1

-

-

... More
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

-

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

-

... More
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

3

-

-

... More
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)

180

-

-

... More
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)

60

-

-

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

10

-

-

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

8

-

-

... More
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)

48

-

-

... More
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)

14

-

-

... More
OD38738/2024-2025:Supply and fixing BS type fuse links 6A to 32 A, 80kA 500 V bolted offset tag type fuse link

12

-

-

... More
OD38739/2024-2025:Supply & fixing 400A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA

3

-

-

... More
OD38740/2024-2025:Supply & fixing 315A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA

2

-

-

... More
OD38741/2024-2025:Supply & fixing 125A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA

3

-

-

... More
OD38737/2024-2025:Supply & fixing 80A to100A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA

9

-

-

... More
OD38743/2024-2025:Supply & fixing 2A to 63A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA

10

-

-

... More
OD38744/2024-2025:Supply and providing 2.00mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength including fixing with suitable synthetic adhesive,

10

-

-

... More
OD38745/2024-2025:Supply and providing 2.5mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive,

10

-

-

... More
OD38746/2024-2025:Supply and providing 3mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 33 KV dielectric strength including fixing with suitable synthetic adhesive,

5

-

-

... More
OD263649/2023-2024:Engaging Helper for one day for cleaning the light fittings/fan/DB etc., dismantling of existing wiring/fittings and conveying to section store.

60

-

-

... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

3

-

-

... More
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N

3

-

-

... More
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N

2

-

-

... More
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N

1

-

-

... More
2.1.8:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.400 Amp TP&N

1

-

-

... More
2.2.1:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB

2

-

-

... More
2.2.3:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.160 Amp, 16KA,TPMCCB

1

-

-

... More
2.20:Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
4.1.8:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 62.5 mm depth X 2.0 mm thickness

10

-

-

... More
4.1.11:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 62.5 mm depth X 2.0 mm thickness

10

-

-

... More
9.4.26:Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 240 sq. mm

1

-

-

... More
9.4.29:Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm

2

-

-

... More
OD89049/2024-2025:Hire and labour charges for providing 125KVA generator with operator for first day

1

-

-

... More
OD89074/2024-2025:Running charges for 125 KVA DG set including cost of fuel

8

-

-

... More
OD89053/2024-2025:Hire and labour charges for providing 125KVA generator with operator for additional day

1

-

-

... More
90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe

10

-

-

... More
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.

3

-

-

... More
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.

0.9

-

-

... More
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).

0.6

-

-

... More
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.

1.1

-

-

... More
OD31418/2024-2025:Supply, conveyance, fabrication and installation of G.I angle / flat frame work.

26

-

-

... More
OD88077/2024-2025: Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Mild steel and Medium Tensile steel bars

20

-

-

... More
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.