Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Apr 2025
Closing Soon25 Apr 2025
Tender Amount₹ 13,09,110 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OD2118/2024-2025:Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for CFL / LED lamps including connection etc as required-

8

-

-

... More
OD2120/2024-2025:Supply and providing the normal size 9w led bulb in the existing fittings as required

8

-

-

... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

23

-

-

... More
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.

5

-

-

... More
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

75

-

-

... More
OD236611/2024-2025:Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

28

-

-

... More
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

1

-

-

... More
OD263305/2023-2024:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.<br>380 mm sweep 900 rpm heavy Duty Exhaust fan in metal frame working on 230 V A/C-

1

-

-

... More
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

2

-

-

... More
OD262555/2023-2024:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.<br>300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C-

2

-

-

... More
OD263250/2023-2024:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.250 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C -

3

-

-

... More
OD262566/2023-2024:supply and fixing 450 mm sweep wall mounting fan with full metal body (Havells /crompton/Bajaj/Orient Make)

11

-

-

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

40

-

-

... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

20

-

-

... More
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

20

-

-

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

8

-

-

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

8

-

-

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

58

-

-

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

2

-

-

... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

-

-

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

5

-

-

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

1

-

-

... More
OD234889/2024-2025:Supply and fixing Surface Led Downlight Luminaire having power consumption not more than 9W and light output not less than 1000Lumens with System efficacy> 110 Lumen/Watt. Housing Shall be made of pressure die cast aluminum body with 60mm height suitable for installation in low heights and polycarbonate diffuser to reduce glare. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5and Co-related color temperature (CCT) of 4000/ 6500K.The LED used in the luminaire shall be of make Lumileds, Osram or Bridgelux only . The luminaire must have 2.5KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,and Operating voltage range 160-270V and driver shall be separately BIS approved of same make equivalent to Philips / kesslec /Osram ( Philips make SM295CLED10s-6500PSU or Equivalent)

4

-

-

... More
OD234911/2024-2025:Supply and fixing Surface Led Downlight Luminaire having power consumption not more than 13.5W and light output not less than 1500Lumens with System efficacy> 110 Lumen/Watt. Housing Shall be made of pressure die cast aluminum body with 60mm height suitable for installation in low heights and polycarbonate diffuser to reduce glare. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5and Co-related color temperature (CCT) of 4000/6500K.The LED used in the luminaire shall be of make Lumileds, Osram or Bridgelux only . The luminaire must have 2.5KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,and Operating voltage range 160-270V and driver shall be separately BIS approved of same make equivalent to Philips / kesslec /Osram. ( Philips make SM296C LED15s-4000 PSU or Equivalent)

4

-

-

... More
OD234918/2024-2025:Supply and fixing Surface Led Downlight Luminaire having power consumption not more than 18W and light output not less than 2000Lumens with System efficacy> 110 Lumen/Watt. Housing Shall be made of pressure die cast aluminum body with 60mm height suitable for installation in low heights and polycarbonate diffuser to reduce glare. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5and Co-related color temperature (CCT) of 4000/6500K.The LED used in the luminaire shall be of make Lumileds, Osram or Bridgelux only . The luminaire must have 2.5KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,and Operating voltage range 160-270V and driver shall be separately BIS approved of same make equivalent to Philips / kesslec /Osram. ( Philips make SM296C LED20S-4000 PSU or Equivalent)

29

-

-

... More
OD234925/2024-2025:Supply and fixing Bulkhead Luminaire having power consumption not more than 9W and light output not less than 1000Lumens with System efficacy> 100 Lumen/Watt. Housing Shall be made of pressure die cast aluminum with ip66 Protection.The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5and Co-related color temperature (CCT) of 4000/6500K.he luminaire must have 2.5KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,and Operating voltage range 160-270V and driver shall be separately BIS approved of same make equivalent to Philips / kesslec /Osram (Philips make WT202W LED10S NW PSU S3 PC or Equivalent)

38

-

-

... More
OD234933/2024-2025:Supply and fixing Industrial grade LED Batten having power consumption not more than 34W and light output not less than 4000 Lumens with System efficacy> 120 Lumen/Watt. Luminaire Housing made from single sheet CRCA body with powder coating. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80 and co-related color temperature (CCT) of 6500K. The luminaire should have 4KV surge protection integrated in driver with 90% driver efficiency, PF≥0.95, operating voltage range 140- 270V with auto cutoff / auto restart features, Ripple<5% and total harmonic distortion THD≤10%. Luminaire and driver shall be separately BIS approved of same make equivalent to Philips / kesslec /Osram (Philips make BN308C LED40S-6500 L120 PSU or Equivalent)

4

-

-

... More
OD234966/2024-2025:Supply and fixing Industrial grade LED Batten having power consumption not more than 17W and light output not less than 2000 Lumens with System efficacy> 120 Lumen/Watt. Luminaire Housing made from single sheet CRCA body with powder coating. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80 and co-related color temperature (CCT) of 6500K. The luminaire should have 4KV surge protection integrated in driver with 90% driver efficiency, PF≥0.95, operating voltage range 140- 270V with auto cutoff / auto restart features, Ripple<5% and total harmonic distortion THD≤10%. Luminaire and driver shall be separately BIS approved of same make equivalent to Philips / kesslec /Osram (Philips make BN308C LED20S-6500 L120 PSU WH or Equivalent)

8

-

-

... More
OD234973/2024-2025:Supply and Installation of Surface Led Downlight Luminaire having power consumption not more than 17W and light output not less than 2000 Lumens with System efficacy> 120 Lumen/Watt. Housing Shall be made of pressure die cast aluminum body with 60mm height suitable for installation in low heights and polycarbonate diffuser to reduce glare. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5and Co-related color temperature (CCT) of 6500K.The LED used in the luminaire shall be of make Lumileds, Osram or Bridgelux only . The luminaire must have 2.5KV surge protection integrated in driver, PF≥0.95, Total harmonic distortion THD≤10%,and Operating voltage range 160-270V and driver shall be separately BIS approved of same make equivalent to Philips / kesslec /Osram. LM80,LM79 ,Type Test certificate and Bis certificate need to be submitted. ( Philips mke SP321P LED20S-4000PSU DIA80 WH or Equivalent)

40

-

-

... More
OD234985/2024-2025:Supply and installation of Architectural Flood Light with a minimum system lumen of 8100Lumen and system wattage not exceeding 100W with a nominal efficiency 80 lumen/watt .The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and corelated color temperature (CCT) of 3000K. The housing should be of Single piece non-corrosive ADC12Grade high-pressure die-cast aluminum and should have corrosion resistant coating to pass Natural salt spray test of 500 Hrs with IP66 Protection. . Luminaire and driver shall be separately BIS approved of same make equivalent to Philips/ kesslec /Osram. ( Philips make BVP353 48 LED30K220VL40 15 or equivalent)

8

-

-

... More
OD234993/2024-2025:Supply and installation of LED Flood Light with a minimum system lumen of 24000Lm and system wattage not more than 200 W with a nominal efficiency 120 lumen/watt . The housing should be of single piece non-corrosive high-pressure ADC 12 Alloy die-cast aluminum with corrosion resistant coating to pass Natural salt spray test of 500 Hrs with IP66 protection.The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related color temperature (CCT) of 5700K. LED used in the luminaire shall be of make of Lumileds, Osram, Nichia, and CREE. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs , should have an auto shutdown at 325V and have an auto recovery feature , Under Voltage protection with Input Voltage Stress of 100V for 48 Hrs Pf>0.95,Thd<10 and 10 Kv SPD bolted inside the luminaire. The SPD should be able to sustain a minimum 15 hits of 10KV rating i.e . Total of 45 hits across all the three modes as per IEEE 62.41.2. Luminaire and driver shall be separately BIS approved of same make equivalent to Philips/ kesslec /Lighting technologies (Philips make BVP283 LED240 CW FG SY5WB 200W V1)

12

-

-

... More
OD235714/2024-2025:Supply and Installation of UP DOWN LED bracket light fittings working on 240 V AC (Wipro garnet 6+6w) or equivalent

10

-

-

... More
OD235928/2024-2025:Supply and Installation of 4W LED Step light (Philips make BWG150) or Equivalent

5

-

-

... More
OD236561/2024-2025:Supply and Installation of 8 W Foot LED Bollard light fittings IP 65, working on 240 V AC supply including giving connections etc complete (Philips make BCP151 LED150/ww) or equivalent

6

-

-

... More
90.12.1.12:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm

120

-

-

... More
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

120

-

-

... More
90.12.7.12:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp

25

-

-

... More
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

14

-

-

... More
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

2

-

-

... More
OD236747/2024-2025:Supply and fixing Sintex Box size 140x140x95 mm

6

-

-

... More
OD236918/2024-2025:Supply and Intallation of Surge Protection Device 3P+N 4 ,50 kA in the existing DB or panel (L and T make AUSP123PN50 or Equivalent)

1

-

-

... More
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.