Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Public Works Department - PWD Tender
Electrical and Electronics
Eprocure
Opening Date27 Jul 2024
Closing DateCancelled
Tender Amount₹ 2,51,673
Costs
EMD
₹ 6,292Document Cost
₹ 555Tender Fee
Refer Documents
Summary
General-maintenance To Ei, Replacing Of Damaged Ups In Pwd Electrical Division And Sub Division Office, Pmg, Thiruvananthapuram.-work- General Electrical Work
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_680019_3Bid Award Id
ViewTender No
PWD/BLDG/TR/2990/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
2
2443
1221.79
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
3
3755
1251.79
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
3
6609
2203.15
90.10.1.1:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface
3
735
245.25
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1
284
284.19
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
3
406
135.54
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1
198
198.53
OD242110/2023-2024:supply and fixing of 20 mm Corrugated PVC flexible conduit as required
20
598
29.94
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
123
12211
99.28
OD242136/2023-2024:1500 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required
2
4003
2001.7
OD76699/2024-2025:Supply and installation of suspended standalone linear fitting of 1800 lumen with aluminium extruded housing, IP 20, UGR<19, efficacy of 100lm/w, inbuilt 4kv surge protection system, power factor > 0.9, THD <10% complete with all accessories suspended from ceiling using 2 nos OEM make string of length not exceeding 1 metre properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (Philips make SP683P LED18S-857 PSU W4L106 AS BK or equivalent)
2
20328
10164
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
100
5805
58.05
OD243105/2023-2024:Supplying and installing CAT 6 information outlet for 1000 Mbps with spring shutter/dust cover face plate+Single RJ45 jack including termination charges etc.on surface/recess using pvc/metal box.Approved make:Actassi, Belden, Molex,Panduit, R and M, Systimax.
3
973
324.49
OD244192/2023-2024:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (usha technoair/polar ps 32/havells efficiencia)
4
12557
3139.32
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
100
6422
64.22
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
4
405
101.45
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
4
527
131.94
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1
395
395.87
OD76615/2024-2025:Supply, installation, and commissioning of 3KVA NUMERIC UPS Single phase in and out. with indoor (IP20) Input pf >0.99, Inernal Isolation transformers at Input, double conversion technology with input voltage range 160-300 @ full load, 50Hz Single Phase, output 230V, 50Hz Single phase, It shall be 100% generator compatible, with Efficiency > 87% and output power factor unity ( 3kVA= 3kW), Eco mode Efficiency 98% and including all accessories etc as required. The acoustic noise at 1m of the system should be <50dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS, Certificates, and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass builtin. The system shall have IGBT rectifier and inverter. The unit shall have a battery back up of 5400 VAH using tubular batteries (12V 100AH x 6 nos or equivalent) including open rack and interconnecting cables.
1
141632
141632.1
OD47480/2024-2025:SITC of 2.0 KVA home Inverter with pure sine wave output, DSP based intelligent control, Ideal for mixed load application, Input voltage of 90-270V AC under normal mode and 195-260V AC under UPS mode, input frequency of 50Hz +/- 5Hz output voltage of 220V +/- 5%, output frequency of 50Hz +/- 0.5Hz having Over load protection, short circuit protection, battery low protection LED and sound indications. (Hykon SP PLUS Home UPS 2000 or equivalent suitable for 2 Nos. 12V Batteries.)
1
19046
19046.33
OD49218/2024-2025:Supply and providing suitable battery rack to accommodate 2 nos tubular batteries
1
2190
2190.12
OD49219/2024-2025:Checking the existing 2 Nos tubular batteries, top-up the battery water if required and giving connections with new Inverter provided.
1
1071
1071.99
OD49252/2024-2025:Charges for dismantling the existing UPSs and Batteries complete and conveying to section store without further damage.
1
1386
1386.99
Evaluation Notes How It Works ?
Potential Partner