Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 2,043Document Cost
₹ 555Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_705182_1Bid Award Id
ViewTender No
PWD/BLDG/EST/8001/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
OD29218/2024-2025:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. - 150 mm, single phase, light duty cooling fan in plastic body (for APFC panel Cooling fan)
1
1715
1715.54
OD29219/2024-2025:Supply and fixing 24Hr timer switch with contactor (cooling fan auto control)
1
2395
2395.22
OD29220/2024-2025:Supply and fixing push button with 1 NO block. (Green with legend 'start')
4
296
1187.6
OD29221/2024-2025:Supply and fixing push button with 1 NC block. (Red with legend 'stop')
4
256
1026.16
OD29222/2024-2025:Supply and fixing mini addon auxiliary contactors add on module 1 NO + 1 NC auxiliary contacts (add in main contactor for manual operation)
5
834
4174.65
OD29223/2024-2025:Supply and fixing Copper wound block reactor transformer, 400 V, 5 KVAr suitable for filtering harmonics up to 7% THD.
1
5639
5639.34
OD29224/2024-2025:Supply and fixing Copper wound block reactor transformer, 400 V, 10 KVAr suitable for filtering harmonics up to 7% THD.
3
8852
26556.48
OD29225/2024-2025:Supply installation testing and commissioning of intelligent power factor controllers-8 stage, 440/110 V, 5 A/ 1 A, Three Phase current and voltage measurement, PF display-3 digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains-DG application, Communication through inbuilt MODBUS RS-485 Protocol.
1
11763
11763.06
OD29226/2024-2025:Supply and Installation of three pole capacitor duty contactors for switching capacitor banks up to 5 kVAr rating with AC coil and 1 NO contact.
1
1501
1501.93
OD29227/2024-2025:Supply and Installation of three pole capacitor duty contactors for switching capacitor banks of 7.5 to 10 kVAr rating with AC coil and 1 NO contact.
2
1748
3496.02
90.14.24.31:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
2
1473
2947.64
90.14.24.34:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty Cylindrical Gas filled Capacitor suitable for APFC panel without block reactor.
4
2830
11322.64
OD29722/2024-2025:Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/ painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required. 20 mm dia
5
81
407.5
OD29720/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.50 sq mm single run with required sockets.
20
28
562.4
OD29721/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4.00 sq mm single run with required sockets.
60
50
3038.4
OD29723/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 6.00 sq mm single run with required sockets.
20
67
1359.4
Evaluation Notes How It Works ?