Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 11,115Document Cost
₹ 980Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_712670_1Bid Award Id
ViewTender No
ET-54/ESDPKD/2024-2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://www.keralapwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
5
-
-
... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
175
-
-
... More
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
95
-
-
... More
1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
110
-
-
... More
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
110
-
-
... More
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
100
-
-
... More
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
14
-
-
... More
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
2
-
-
... More
OD197866/2023-2024:Supply installation, testing and commissioning of wall mounting split air conditioner units of the following ratings conforming to the relevant IS suitable for operating on 230 volt, 50HZ single phase AC supply filled with R32 / 410A eco friendly refrigerant gas high energy efficient ROHS complaint capable of performing functions like cooling, dehumidifying air circulating filtering etc of following capacity including copper piping 3 mtr with insulation , control cable upto 3-5 mtr , 3mtr drain pipe , copper condensor , stand microprocessor control with cordless remote control etc .PCB should have minimum 5years warranty and 10 year warranty on compressor (warranty card to be provided), Minimum 2 nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 1.0 TR 3star and above inverter ac unit Blue star/ LG / Daikin/ Carrier/ Panasonic/ Hitachi
2
-
-
... More
OD206826/2023-2024:Supply installation, testing and commissioning of wall mounting split air conditioner units of the following ratings conforming to the relevant IS suitable for operating on 230 volt, 50HZ single phase AC supply filled with R32 / 410A eco friendly refrigerant gas high energy efficient ROHS complaint capable of performing functions like cooling, dehumidifying air circulating filtering etc of following capacity including copper piping 3 mtr with insulation , control cable upto 3-5 mtr , 3mtr drain pipe , copper condensor , stand microprocessor control with cordless remote control etc .PCB should have minimum 5years warranty and 10 year warranty on compressor (warranty card to be provided), Minimum 2 nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 1.5/1.8 TR 3star and above inverter ac unit Blue star/ LG / Daikin/ Carrier/ Panasonic/ Hitachi
2
-
-
... More
OD197867/2023-2024:Supply installation, testing and commissioning of wall mounting split air conditioner units of the following ratings conforming to the relevant IS suitable for operating on 230 volt, 50HZ single phase AC supply filled with R32 / 410A eco friendly refrigerant gas high energy efficient ROHS complaint capable of performing functions like cooling, dehumidifying air circulating filtering etc of following capacity including copper piping 3 mtr with insulation , control cable upto 3-5 mtr , 3mtr drain pipe , copper condensor , stand microprocessor control with cordless remote control etc .PCB should have minimum 5years warranty and 10 year warranty on compressor (warranty card to be provided), Minimum 2 nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 2.0/2.2 TR 3star and above inverter ac unit Blue star/ LG / Daikin/ Carrier/ Panasonic/ Hitachi
1
-
-
... More
OD273239/2022-2023:Supply of providing 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V.
3
-
-
... More
OD207385/2023-2024:Supply of providing 4 KVA voltage stabiliser for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V. V Guard make VG400 plus/eqt
2
-
-
... More
OD273240/2022-2023:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge
17
-
-
... More
OD273241/2022-2023:Supply and drawing the following sizes of multi-core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.5 sq. mm.
13
-
-
... More
OD273242/2022-2023:Supply and providing 32mm/nearest size pvc pipe complete with standard accessories as drain pipe as required.
24
-
-
... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
... More
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
1
-
-
... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
... More
OD277191/2022-2023:Supplying and fixing FP enclosure MCB DB sheet steel Phosphatised, painted, dust and vermin proof enclosure on surface/ recess complete with connections, testing and commissioning etc. as required
1
-
-
... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
10
-
-
... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2
-
-
... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2
-
-
... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
... More
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2
-
-
... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
20
-
-
... More
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
3
-
-
... More
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
3
-
-
... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
35
-
-
... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
4
-
-
... More
OD273385/2022-2023:Supply & installation of dust and vermin proof, 3 Phase Sintex Meter Board( GS-JB- 6535 (650 x 350 x 210) including p/f 3 Nos 63 A HRC Fuse Base with HRC Fuse link ,32/40 A neutral link and to fix KSEB meters, etc as required including fixing it on wall, making good the damages colour washing etc. as required
1
-
-
... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.