Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_693700_1Tender No
PWD/BLDG/6792/2024-2025Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
90.14.2.4:Supply and providing 5mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
0.16
-
-
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
6
-
-
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
20
-
-
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
2
-
-
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
250
-
-
OD226019/2022-2023:Supply, installation, and testing of Digital Multifunction meter to read: V, A, F, 3 phase accuracy class 1
1
-
-
OD226018/2022-2023:Supply Installation and Testing of LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
3
-
-
90.14.28.3:S & F Motor starters of the following ratingsThree phase DOL starters for 10HP motor
1
-
-
90.12.7.14:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
40
-
-
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
4
-
-
90.17.7.1:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia
160
-
-
90.17.7.2:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :32 mm dia
115
-
-
90.17.7.3:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm dia
30
-
-
90.17.7.4:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia
10
-
-
90.17.7.5:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia
28
-
-
90.17.7.6:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia
18
-
-
90.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
125
-
-
90.17.11.4:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia
3
-
-
90.17.11.5:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
3
-
-
90.17.14.5:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia
1
-
-
90.17.9.1:Supplying and fixing single headed internal hydrant valve with instantaneous
Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming
to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal
4
-
-
90.17.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
b. 20 mm nominal internal dia gun metal globe valve & nozzle.
c. Drum and brackets for fixing the equipmets on wall.
d. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
30 m
4
-
-
OD225822/2022-2023:Supplying and fixing of double hose cabinet fabricated from 2mm thick MS sheet with 6mm thick glazed front glass doors and looking arrangements suitable for accommodate internal accommodate of 2 no. of 15 Mtrs long hose pipe, 1 No. branch pipe, fittings etc. The cabinet shall be painted with one coat of primer and 2 coatts of synthetic enamel paint of post office red externally and white internally and shall be suitably mounted on concrete base.
4
-
-
90.17.16.1:Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal
8
-
-
90.17.18.1:Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal
4
-
-
OD117002/2024-2025:Supplying, fixing, testing and commissioning of 0-15 Kg/sq cm100mm dia Dial type pressure gauge with isolation cock and pipe at hydrant station as per specification.
1
-
-
90.17.22:Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
1
-
-
OD117009/2024-2025:Supply, installation ,testing and commissioning of 25mm gun metal air release valve as per IS 14845 ISI marked
1
-
-
OD225697/2022-2023:FIRE BRIGADE INLET Supply, installation, testing and commissioning of 4way Fire Brigade Inlet connection of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arrangement to be connected to wet riser main.
1
-
-
90.17.21.1:Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler
80
-
-
OD225695/2022-2023:Supply and fixing of 5Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per lS 15683 with Fire rating 1A BB, Body Hydro tested at 35 bar, Operating temperature -30 degree C to +55 degree C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with Standard accessories. including supply & fixing suitable bracket on wall for fixing bucket
10
-
-
OD225694/2022-2023:Supply and installation, testing and commissioning of CO2 type fire extinguisher with 4.5kg. Capacity complete with installation brackets with ISI mark IS:15638 Make: SAFEX/BHARAT/KANEX including fixing suitable bracket for fixing bucket
3
-
-
17.1.3:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call boxes of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button etc. as required.
3
-
-
17.1.6:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
3
-
-
17.1.9.1:Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.4 Zone
1
-
-
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
360
-
-
OD139147/2024-2025:Supply and providing emergency fire escape lighting system system consisting of 2 Nos LED lamp,7AH FMF battery charging exit sign display etc.
8
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
180
-
-
OD225820/2022-2023:Supply & installation of necessary Glow Sign Boardmade of 3mm thick PVC foam board for each floor 12" x 4" (Fire Lift, Passenger Lift, Electrical Duct, Fire Station, Main Stair, Fire Exit, Floor Display & Pump Room)
15
-
-
OD225699/2022-2023:Supply & erection of 3mm thick PVC foam board Assembly Point sign board 16" x 16"
1
-
-
OD225700/2022-2023:Charges for preparation of electrical/fire/DG drawing per A3 sheet first copy.
6
-
-
OD225819/2022-2023:Preparation of fire fighting sytem drawing and check list as per new fire rule, conducting fire force inspection and obtaining NOC from Frie Froce department
1
-
-
OD243664/2022-2023:Supply & erection of Fire Escape rout in each floor having size 12'' x 16''
6
-
-
17.2.17:Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required
1
-
-
Fire fighting system in court complex
-
-
-
OD128833/2024-2025:Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a. Horizontal type, multistage, centrifugal, mono block pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b. Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head
3
-
-
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
8
-
-
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
40
-
-
OD88679/2023-2024:Supply Installation and Testing of LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
9
-
-
OD88680/2023-2024:Supply, installation, and testing of Digital Multifunction meter to read: V, A, F, 3 phase accuracy class 1
3
-
-
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
700
-
-
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
15
-
-
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
3
-
-
90.6.4.53:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 3 Run
1.5
-
-
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
3
-
-
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
3
-
-
90.12.7.14:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
85
-
-
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
6
-
-
90.17.7.6:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia
6
-
-
90.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
180
-
-
90.17.11.5:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
9
-
-
90.17.14.5:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia
3
-
-
90.17.9.1:Supplying and fixing single headed internal hydrant valve with instantaneous
Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming
to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal
10
-
-
90.17.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
b. 20 mm nominal internal dia gun metal globe valve & nozzle.
c. Drum and brackets for fixing the equipmets on wall.
d. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
30 m
10
-
-
OD88144/2023-2024:Supplying and fixing of double hose cabinet fabricated from 2mm thick MS sheet with 6mm thick glazed front glass doors and looking arrangements suitable for accommodate internal accommodate of 2 no. of 15 Mtrs long hose pipe, 1 No. branch pipe, fittings etc. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of post office red externally and white internally and shall be suitably mounted on concrete base.
10
-
-
90.17.16.1:Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal
20
-
-
90.17.18.1:Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal
10
-
-
OD88143/2023-2024:Supplying, fixing, testing and commissioning of 0-15 Kg/sq cm100mm dia Dial type pressure gauge with isolation cock and pipe at hydrant station as per specification.
3
-
-
90.17.22:Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
3
-
-
OD88148/2023-2024:AIR RELEASE VALVE Supply, installation, testing and commissioning of 25mm Air release valve as per IS:14845 ISI Marked
3
-
-
OD88147/2023-2024:FIRE BRIGADE INLET Supply, installation, testing and commissioning of 4way Fire Brigade Inlet connection of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arrangement to be connected to wet riser main.
3
-
-
OD88146/2023-2024:Supply and fixing of 5Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per lS 15683 with Fire rating 1A BB, Body Hydro tested at 35 bar, Operating temperature -30 degree C to +55 degree C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with Standard accessories. including supply and fixing suitable size bracket for fixing bucket on wall
24
-
-
OD88145/2023-2024:Supply and installation, testing and commissioning of CO2 type fire extinguisher with 4.5kg. Capacity complete with installation brackets with ISI mark IS:15638 Make: SAFEX/BHARAT/KANEX including supply and fixing suitable size bracket for fixing bucket on wall
6
-
-
17.1.3:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call boxes of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button etc. as required.
10
-
-
17.1.6:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
10
-
-
17.1.9.2:Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.6 Zone
1
-
-
17.1.9.1:Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.4 Zone
2
-
-
OD139144/2024-2025:Supply and providing emergency fire escape lighting system system consisting of 2 Nos LED lamp,7AH FMF battery charging exit sign display etc.
24
-
-
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
2500
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1150
-
-
OD88142/2023-2024:Supply & installation of necessary Glow Sign Board made of 3mm thick PVC foam board as per new fire rules like Fire Station, Fire Exit, passenger Lift, Electrical Duct, Plumbing Duct, Floor level, Fire Lift in each floor and Pump Room
41
-
-
OD88149/2023-2024:Supply & erection of 3mm thick PVC foam board Assembly Point sign board 16" x 16"
6
-
-
OD88140/2023-2024:Supply & erection of Fire Escape rout in each floor having size A3
10
-
-
OD88141/2023-2024:Preparation of fire fighting sytem drawing and check list as per new fire rule, conducting fire force inspection and obtaining NOC from Frie Froce department
1
-
-