Public Works Department Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Feb 2025
Closing Soon28 Feb 2025
Tender Amount₹ 8,26,00,740 
Notes
Download

Costs

Summary

General-budget Work - 2022-2023- Construction Of Mini Civil Station Ponnani Phase-1 -construction Of New Mini Civil Station Building Phase-1 At Ponnani In Malappuram District (ponnani Lac)-composite Work

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

24.06

107

2575.3

... More
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m

203.55

153

31332.45

... More
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

60

286

17184

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

160.58

337

54182.9

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

393.56

721

284030.81

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1183.59

869

1028571.74

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2468.87

653

1614342.1

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

142.49

6857

977160

... More
OD218626/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge-All work up to plinth level. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement content as per design mix is not payable or recoverable separately. Details of cost for 1.00m3.

675.5

9555

6454494.27

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

89124.48

98

8816193.56

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

1743.59

820

1431243.29

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

369.4

205

75804.57

... More
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

201.04

908

182584.72

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

116.76

737

86067.3

... More
OD218625/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement content as per design mix is not payable or recoverable separately. All work above plinth level up to floor V level.

701.3

11217

7866872.04

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

108597.97

98

10742510.99

... More
OD218629/2024-2025:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site REF: 60.7.1

36.24

3513

127327.68

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

1245.88

260

324151.76

... More
13.65.1:Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work

411.6

125

51701.2

... More
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

140.11

6665

933861.85

... More
50.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

105.15

7664

805958.09

... More
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

35.87

7008

251423.98

... More
50.6.2.3:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

75.21

8008

602278.45

... More
6.47:Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

23.29

7861

183105.17

... More
4.2.2:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:11/2:3 (1 cement : 11/2 coarse sand :3 graded stone aggregate 20 mm nominal size)

3.84

10632

40828.15

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

4534.77

316

1433348.52

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

2847.65

293

834731.35

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2115.13

269

569519.1

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

877.12

403

354127.62

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

6680.18

71

474960.44

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

6680.18

152

1017925.07

... More
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2852.89

195

556598.06

... More
OD218630/2024-2025:Providing and laying Matt finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08 % and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand0, including grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.7 kg of organic coated filler of desired shade (0.10kg f hardener and 0.20Kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer - in - charge. Size of Tile 600 x 600mm

1330.01

1911

2542072.8

... More
OD218628/2024-2025:Providing and laying Matt Finished Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand),Including Epoxy filling the joints with matching colour etc. complete.Size of Tile 600x600 mm.REF DSOR 11.46.2

86.86

1964

170680.36

... More
OD218631/2024-2025:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) Excluding pointing the joints with white cement and matching pigments etc., complete. ref DSOR 11.40

147.86

1343

198721.82

... More
OD218632/2024-2025:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 300x300 mm . REF 11.48.2

147.86

556

82230.13

... More
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

368.44

551

203177.72

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

592.85

1220

723489.38

... More
11.20.3:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

183

1099

201151.4

... More
8.13.1:Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

51.08

4177

213378.2

... More
8.3.2:Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

38.63

445

17214.69

... More
8.2.2.1:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shadeArea of slab upto 0.50 sqm

97.2

4995

485546.08

... More
16.90:Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

2.18

2290

4981.82

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

48.94

442

21646.6

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

137.36

573

78821.51

... More
OD218634/2024-2025:Filling 6 mm broken stone in sunken slab including all cost carriage of materials and labour charges for sunken floor filling etc.complete

7.48

2667

19944.5

... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.55

154198

84346.54

... More
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

44

212

9339.88

... More
9.5.1.1:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood35 mm thick shutters

24.75

4345

107543.7

... More
9.7.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

14.08

3485

49069.64

... More
13.68.1:French spirit polishing:Two or more coats on new works including a coat of wood filler

82.37

415

34257.67

... More
9.81.1:Providing and fixing bright finished brass handles with screws etc. complete:125 mm

44

242

10666.92

... More
OD218638/2024-2025:Supplying and fixing 300 mm Stainless steel aldrop REF DSOR : 50.9.15.2

11

409

4506.7

... More
OD218639/2024-2025:Providing and fixing bright finished SS tower bolts with necessary screws etc. complete:300x20 mm REF DSOR : 9.63.1

33

470

15517.92

... More
9.147D.5:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)

256.68

9685

2486079.27

... More
9.147E.1:Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.)

56.4

8127

458382.54

... More
9.147B.1:543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

7.92

7673

60777.45

... More
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

4815

195

942825.15

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

361.26

143

51999.76

... More
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

321

1535

492911.55

... More
9.147F.1:Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)

6.3

7112

44810.2

... More
9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

200.4

805

161374.1

... More
9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

68.4

4104

280721.81

... More
21.18:Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

13.2

6629

87504.91

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

881.32

540

476306.69

... More
OD218636/2024-2025:Providing and fixing 12 mm thick Multi wood sheet in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge. . REF DSOR 21.2.1

287.38

1966

565055.18

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

140.99

1184

166937.12

... More
25.2:Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to ? 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr? 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.? 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml? 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm? 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test? Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml?

12.19

3493

42588.65

... More
25.3:Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement

68.9

3850

265294.38

... More
25.4:Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.

4.5

3746

16859.7

... More
25.1:Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

182.07

438

79888.67

... More
10.5.2:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece

20.13

5067

102005.35

... More
10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

5.4

3320

17932.48

... More
10.7:Providing and fixing ball bearing for rolling shutters.

2

497

994.64

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

623.7

681

425120.16

... More
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

2355.12

187

440807.81

... More
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

266.5

191

50922.82

... More
OD218635/2024-2025:Providing & fixing Poly carbonate solid sheet 3 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal / vertical / curved surfaces, but excluding the cost of purlins, rafters, trusses and including cutting to size and shapes where ever required. REF 50.12.2.2

26.04

1874

48811.72

... More
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

105.98

224

23820.96

... More
12.45.1:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1

46.2

1323

61158.64

... More
13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

46.2

136

6300.29

... More
OD218627/2024-2025:Show wall brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 12.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand) size of 30x10x5 cm with 5cm exposed REF DSOR 6.13.2

87.15

3564

310618.29

... More
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

155.04

101

15800.13

... More
OD218637/2024-2025:Providing and fixing stainless steel (304) 3D letters of 18 Guage , 12 to 20mm Projection of different heights , including welding grinding , buffing , polishing and making curvature ( Where ever Required ) and fitting the same with necessary stainless steel nuts and bolts complete with suitable arrangement as per approval of engineer incharge ( for payment purpose number and height of letters shall be considered excluding fixing accessories such as nuts , bolts , fasters , etc )

1250

66

83075

... More
30.2.10.1:Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately).In rows 5 cm apart in both directions

14.84

21

318.32

... More
30.2.8:Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

3.71

63

235.77

... More
9.136:Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer -in-charge (Dash fastener to be paid for separately ).

5.8

1710

9922.35

... More
9.137:Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge ( panneling to be paid for separately).

0.68

7303

4929.82

... More
9.138.1:Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size. made out of 20 SWG G.I. sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-chargeWith clear fire resistant glass panes 6 mm thick of approved brand, having minimum 60 minutes fire resisitance

1.4

37560

52622.2

... More
OD218633/2024-2025:Providing and Fixing Defect liability Board for building using Aluminum composite panel (ACP) material with a HD vinyl print

1

1800

1800.41

... More
APPENDIX -B- WATER SUPPLY AND SANITARY INSTALATION(Civil work)

-

-

-

... More
17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

6

6421

38529.78

... More
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

19

6231

118397.74

... More
17.81:Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.

3

18309

54928.65

... More
17.4.1:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern

9

5901

53111.97

... More
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

33

2973

98127.48

... More
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

25

67

1676.5

... More
50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.

25

758

18953.75

... More
50.17.1.2:Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

25

87

2191

... More
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

20

1519

30394.2

... More
OD218617/2024-2025:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110x75x50 mm Floor trap

35

690

24169.25

... More
OD218616/2024-2025:Providing and fixing SS rectangular type 150x150 mm square with 100 mm diameter grating of approved quality,

35

361

12657.4

... More
18.33.1:Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

10

11001

110018.7

... More
18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

30

630

18903.9

... More
18.15.2:Providing and fixing brass bib cock of approved quality :20 mm nominal bore

26

386

10052.64

... More
18.16.2:Providing and fixing brass stop cock of approved quality :20 mm nominal bore

15

386

5799.6

... More
18.54.2:Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 122 mm long, weighing not less than 99 gms

4

191

767.76

... More
18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

5

803

4017.7

... More
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

5

1029

5147.6

... More
18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

15

466

7000.05

... More
OD218618/2024-2025:Providing and fixing Automatic Water Level Control Valve/Flot Valve, Inside Type,Used for Water Tank ,of approved quality as per the direction of engineer in charge

1

1498

1498.86

... More
OD218619/2024-2025:Providing and fixing Standered threaded PVC Ball Valve with handle approved quality :40 mm nominal bore Ref:18.17.3

2

333

666.46

... More
50.18.9.16.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall

15

427

6406.8

... More
50.18.9.6.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2

30

284

8545.2

... More
50.18.8.6.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2

2

486

972.94

... More
50.18.8.5.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

2

477

954.82

... More
50.18.9.15.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall

39

419

16344.9

... More
50.18.8.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

15

448

6730.95

... More
50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

40

328

13146.4

... More
50.18.9.4.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2

25

239

5992

... More
50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

50

423

21153

... More
50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall

50

277

13861

... More
50.18.9.3.2:Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2

20

216

4339.6

... More
50.18.8.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2

6.25

411

2573.31

... More
50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2

12.5

612

7655

... More
50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall

50

269

13454.5

... More
50.18.9.7.1:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2

20

348

6964.6

... More
50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

110

282

31075

... More
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

135

382

51638.85

... More
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

44

527

23225.84

... More
50.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

30

904

27141.3

... More
50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow

10

64

644.5

... More
50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow

10

80

807.1

... More
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend

10

79

795.5

... More
50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee

10

86

863.5

... More
50.18.9.20.6:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee

10

94

944.8

... More
50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl

5

76

383.2

... More
50.18.9.20.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer

10

63

638.7

... More
50.18.9.21.2:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow

25

70

1771

... More
50.18.9.21.3:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow

25

95

2380.75

... More
50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend

20

88

1776.8

... More
50.18.9.21.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee

5

95

478.25

... More
50.18.9.21.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee

10

107

1072.6

... More
50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

5

87

435.5

... More
50.18.9.21.10:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x63 mm dia Reducer

10

70

708.4

... More
50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow

20

105

2111.6

... More
50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow

25

132

3307.25

... More
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

30

161

4839.9

... More
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

8

175

1400.72

... More
50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee

10

187

1878.7

... More
50.18.9.22.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee

10

180

1809

... More
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

10

124

1241.6

... More
50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer

6

107

647.4

... More
18.8.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

15

665

9984.3

... More
18.8.4:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

14

804

11261.88

... More
APPENDIX -C- CONSTRUCTION OF SUMP,SEPTIC,RH,SOAK PIT ,FIRE TANKS(Civil work)

-

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

482.17

215

103843.88

... More
2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m

321.8

167

53814.61

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

221.45

107

23706.22

... More
OD218622/2024-2025: DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site.

14.35

3513

50423.74

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

11.56

6857

79260.14

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

34.12

337

11512.77

... More
OD218624/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge-All work up to plinth level. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement content as per design mix is not payable or recoverable separately. Details of cost for 1.00m3.

75.11

9555

717687.32

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

9388.75

98

928735.15

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

366.32

721

264373.14

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

336.32

442

148754.34

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

195.55

260

50877.16

... More
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

7.18

6665

47830.19

... More
10.31:Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge.

16.9

113

1925.59

... More
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

3.6

5244

18881.96

... More
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

22.5

195

4405.73

... More
OD218623/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement content as per design mix is not payable or recoverable separately. All work above plinth level up to floor V level.

4.87

11217

54629.81

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

487

98

48174.04

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

7.52

653

4917.18

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

34.32

820

28171.92

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

23.6

205

4842.96

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

166.68

293

48858.91

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

289.91

403

117048.26

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

35.88

316

11340.95

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

34.32

269

9241

... More
23.5:Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.68

1571

1060.61

... More
23.6:Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.68

1571

1060.61

... More
23.7:Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.68

1571

1060.61

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

3.6

143

518.18

... More
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

70.2

168

11822.38

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

112.5

155

17454.38

... More
12.42.2.2:Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm

90

128

11558.7

... More
APPENDIX -D- CONSTRUCTION OF COMPOUND WALL AND GATE(Civil work)

-

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

12

215

2584.44

... More
OD218620/2024-2025: DRY RUBBLE MASONRY _ Dry rubble masonry with hard stone in foundation and plinth including of all charges etc. complete.

27

3513

94860.72

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

10.13

7249

73405.44

... More
OD239617/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for RCC work using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering shuttring, finishing and reinforcement including admixture in recommended properties as per IS:8103 to accelarate retard setting of concrete ,improve workability without impairing strength and durability as per direction of engineer -in charge. cement content considered for this work is 340kg/cm3 of concrete .excess /less cement as per mix design is not payable /not recoverable. detailed mix design to be supplemented .All work up to plinth level

3.38

9513

32109.58

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

15

653

9808.2

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

337.5

98

33385.5

... More
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

24.64

6665

164232.99

... More
4.2.2:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:11/2:3 (1 cement : 11/2 coarse sand :3 graded stone aggregate 20 mm nominal size)

1.47

10632

15640.16

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

360

316

113788.8

... More
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

360

168

60627.6

... More
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

220

1017

223933.6

... More
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

315

153

48289.5

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

10.5

143

1511.37

... More
Electrification(Electrical work)

-

-

-

... More
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

383

1184

453487.32

... More
1.54.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

28

845

23687.16

... More
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

52

479

24945.44

... More
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

66

1252

82673.58

... More
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture

25

1289

32239

... More
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture

127

1514

192355.47

... More
90.3.10:Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.

100

234

23463

... More
OD249969/2024-2025:Supply, conveyance, installation, testing commissioning of 5 watts, LED mirror lamp, Operating Voltage: 160-360 volts Philips, Crompton or equivalent make

10

596

5969.3

... More
OD239513/2024-2025:Supply,Conveyance, installation, testing and commissioning of 1800 lumen square surface/recess mount fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea and giving necessary connections as required

11

2022

22247.28

... More
OD239548/2024-2025:Supply and fixing pressure die cast housing LED Bulkhead with IP65 protection and IK08 impact resistance suitable for surface and wall mounting applications including giving connection with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the Original wiring and making good the surface as required. (Philips make VistaGlow WT140W LED7S NW/CW PSU S1 PC or Techno commercial equivalent )

45

1049

47208.15

... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

109

175

19146.94

... More
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

109

408

44577.73

... More
OD242070/2024-2025:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

109

3140

342324.31

... More
1.47:Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

100

39

3968

... More
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

10

478

4781

... More
OD239506/2024-2025:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 cores round copper conductor flex wire conforming to relevant ISS. 300/305 mm sweep, 1400 rpm Heavy Duty Exhaust fan in metal frame working on 230 V A/C

10

2697

26976.6

... More
1.51:Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes

16

200

3209.76

... More
90.15.3.1:Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters

5

18665

93326.85

... More
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm

40

83

3322.4

... More
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

5

7511

37557.85

... More
90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe

6

449

2695.08

... More
OD239546/2024-2025:Supply, Conveyance, installation, testing and commissioning of LED Post top Luminaire having power consumption not more than 25 W and light output not less than 2500 Lumens with a nominal efficiency 100 lumen/watt. Internal surge protection up to 4 KV ,IK 5 with IP 65 protection. The housing should be of non-corrosive ADC12Grade high-pressure die-cast. The Luminaire diameter must be minimum 300mm for larger area coverage .The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related colour temperature (CCT) of 4000-5700K. The luminaire should be capable of withstanding voltage stress of `440V for 8 Hrs , should have an auto shutdown at 325V and have an auto recovery feature , Under Voltage protection with Input Voltage Stress of 100V for 48 Hrs. The Luminaire should have a 4 KV in the Luminaire. Total of 45 hits across all the three modes as per IEEE 62.41.2 The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire with PF>0.95 and THD<10%.Luminaire and driver shall be separately BIS approved of same make equivalent to Philips/ kesslec /Osram. LM80,LM79 ,Type Test certificate and Bis certificate need to be submitted.

2

8983

17967.1

... More
OD250385/2024-2025:Supply, Conveyance, installation, testing and commissioning of of LED Post top Luminaire having power consumption not more than 35 W and light output not less than 3500 Lumens with a nominal efficiency 100 lumen/watt. Internal surge protection up to 4 KV ,IK 5 with IP 65 protection The housing should be of non-corrosive ADC12Grade high-pressure die-cast. The Luminaire diameter must be minimum 300mm for larger area coverage .The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI &ge;70, SDCM&lt; 5 and corelated colour temperature (CCT) of 4000- 5700K. The luminaire should be capable of withstanding voltage stress of `440V for 8 Hrs , should have an auto shutdown at 325V and have an auto recovery feature , Under Voltage protection with Input Voltage Stress of 100V for 48 Hrs. The Luminaire should have a 4 KV in the Luminaire. Total of 45 hits across all the three modes as per IEEE 62.41.2 The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire with PF&gt;0.95 and THD&lt;10%.Luminaire and driver shall be separately BIS approved of same make equivalent to Philips/ kesslec /Osram. LM80,LM79 ,Type Test certificate and Bis certificate need to be submitted.

2

10460

20920.08

... More
OD239520/2024-2025:Supply and fixing Sintex junction box GS-JB- 1414 with provision for fixing SP/DP MCB for terminating street light cable

4

732

2929.8

... More
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell

4

191

766.88

... More
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

4

109

439.16

... More
1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep

8

197

1578.96

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

7

290

2034.13

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

45

319

14395.5

... More
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface

14

251

3527.72

... More
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

1

342

342.89

... More
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

43

398

17129.05

... More
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface

20

284

5698.6

... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

1

457

457.93

... More
90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box

15

177

2664.6

... More
OD239550/2024-2025:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 6 module mounting box

51

183

9364.11

... More
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

29

153

4437.58

... More
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

71

199

14184.38

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

272

102

27765.76

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

29

157

4568.95

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

273

132

36246.21

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

29

209

6063.03

... More
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator

8

565

4523.76

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

2950

99

294705

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

350

108

37856

... More
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

15

110

1653.6

... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

1350

64

87237

... More
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm

935

119

111826

... More
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm

110

193

21322.4

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

300

89

26949

... More
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm

50

170

8501

... More
1.17.18:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 2.5 sq. mm

15

269

4042.05

... More
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

750

139

104835

... More
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm

50

264

13208

... More
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm

50

199

9991

... More
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm

250

390

97507.5

... More
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

7658

7658.5

... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

6

6557

39345.48

... More
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

7

2850

19950.07

... More
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

2

2105

4210.76

... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

19

2455

46656.59

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

15

404

6074.85

... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

10

995

9954

... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

5

1003

5016.65

... More
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

19

2506

47625.21

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

10

3141

31411.5

... More
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

3

3321

9965.43

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

17

988

16799.06

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

261

238

62271.99

... More
OD239504/2024-2025:Supplying and fixing 0.5 amps to 4 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB/panel board complete with connections, testing and commissioning etc. as required.Single pole

24

346

8309.52

... More
OD239505/2024-2025:Supplying and fixing following rating miniature type double pole AC change over switch with centre OFF in the existing MCB DB/Enclosure complete with connections, testing and commissioning etc. as required. 40 A, 2 pole, 2 way ( L&T make or Techno commercial equivalent.)

7

2293

16051.91

... More
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

14

1014

14207.9

... More
90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

4651

4651.91

... More
90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid

25

780

19517.5

... More
90.9.1.7:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

4

100

402.52

... More
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

110

1089

119863.7

... More
90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider

110

131

14432

... More
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree

6

251

1510.44

... More
90.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree

5

371

1855.2

... More
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

5

251

1258.7

... More
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

10

142

1423.8

... More
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp

75

200

15019.5

... More
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

190

223

42411.8

... More
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

30

245

7354.8

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

135

276

37347.75

... More
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

180

328

59191.2

... More
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

125

580

72583.75

... More
90.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm

35

685

23977.45

... More
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm

125

180

22512.5

... More
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm

30

203

6091.5

... More
90.12.5.30:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm

45

553

24922.8

... More
90.12.5.31:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 95 sq mm

20

658

13164.6

... More
90.12.6.31:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 95 sq mm

70

634

44429

... More
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

8

236

1893.92

... More
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

14

236

3314.36

... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

2

262

524.2

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

5

298

1492.7

... More
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

5

298

1492.7

... More
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

8

440

3520.24

... More
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

6

566

3396.6

... More
90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size

5

328

1642.55

... More
90.12.10.5:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation90/75 mm or nearest size

40

385

15416.4

... More
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)

400

44

17896

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

100

63

6363

... More
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

160

98

15723.2

... More
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)

100

25

2514

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

35

27

945.7

... More
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

20

27

554.2

... More
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

100

477

47769

... More
90.16.4.8:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip

40

549

21993.2

... More
OD239524/2024-2025:Supply and provide 12x3mm brass nut and bolt etc. as required

50

20

1021

... More
OD239562/2024-2025:Supply and providing 25x3mm brass nut and bolt etc. as required

75

22

1678.5

... More
OD239540/2024-2025:Supply and providing 25x6mm brass nut and bolt etc. as required

65

23

1518.4

... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

7

7436

52054.52

... More
OD239539/2024-2025:Providing and fixing 25 mm X 6 mm G.I. strip earth lead from the test joint to the earth plate

35

233

8169.35

... More
OD239531/2024-2025:Providing and fixing 25 mm X 6 mm G.I. strip test joint for earthing system

1.75

233

408.47

... More
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

78.29

2536

198576.32

... More
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

6.3

3414

21509.77

... More
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

193.8

46

9081.47

... More
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

8405

6

55473

... More
90.14.7:Supply and providing copper earth bus in the panel board

3915

6

24586.2

... More
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

125

166

20766.25

... More
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

19.4

1036

20107.13

... More
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

20

7713

154265.4

... More
90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

8

3820

30562.48

... More
90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

1

17750

17750.58

... More
90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

1

23148

23148.29

... More
2.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N

3

8011

24033.09

... More
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N

1

3497

3497.23

... More
OD239566/2024-2025:Supply and fixing Three Phase ACCL , EB/DG 63A / 63A, in the existing panel board/Enclosure and giving necessary connections,testing and commissioning etc as required.( make L&T, HPL, Socomec, Havells,Techno commercial equivalent approved by engineer in charge)

2

11974

23948.28

... More
OD239567/2024-2025:Supplying and fixing Single Phase ACCL EB/DG 32A / 32A in the existing panel board/enclosure and giving necessary connections,testing and commissioning etc as required.(L&T make or Techno commercial equivalent approved by engineer in charge)

4

2069

8277.56

... More
OD239563/2024-2025:Supply and fixing Three Phase ACCL EB/DG 32A / 32A in the existing panel board/Enclosure and giving necessary connections,testing and commissioning etc as required (L&T make or Techno commercial equivalent approved by engineer in charge)

2

6992

13984.96

... More
OD239568/2024-2025:Supply and providing Automatic Transfer switch , Frame 2 size of Motorized change over 125A ,4P AC 23A ,manual change over handle with Automatic Transfer Controller unit with Illuminated Push Button assembly, wire harness and giving necessary connections,testing and commissioning etc as required for auto start operation for existing DG set. including all additional aux. contractor/supply unit/control unit (L&T make, HPL, Havells, Socomec or Techno commercial equivalent approved by engineer in charge)

1

55364

55364.48

... More
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

30

1924

57723.9

... More
90.14.11.3:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT.

1

3814

3814.08

... More
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.

11

1368

15051.08

... More
OD239502/2024-2025:Supply & fixing the Push button station enclosure with 1/ 2/ 3 hole.

4

332

1329

... More
OD251206/2024-2025:Supply and fixing push button NO/NC in the existing panel board and giving connection etc. as required

4

142

571.28

... More
OD239555/2024-2025:Supply and wiring with ISI marked, FRLS PVC insulated following size single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc with sockets as required. 1.5 Sq mm single run

60

23

1390.2

... More
OD251218/2024-2025:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 2.5Sqmm single run

15

93

1400.4

... More
OD251211/2024-2025:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10Sqmm single run

10

165

1655.8

... More
OD251212/2024-2025:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 6Sqmm single run

15

123

1854

... More
OD239549/2024-2025:Supply and fixing 150/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT and giving necessary connections as required.

6

883

5301.9

... More
OD239492/2024-2025:Supply and fixing 100/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT and giving necessary connections as required. including Test fee

4

1160

4640.92

... More
OD239547/2024-2025:Supply and fixing Red, Green, blue, Yellow, Orange colours LED indicator, AC/DC, as required

15

93

1401.3

... More
OD239515/2024-2025:Supply and fixing Digital Multifunction meter to read: V, A, F, PF-3 phase accuracy class 1 LED and giving necessary connections as required.

3

2010

6032.67

... More
OD239536/2024-2025:Supply and fixing 125 A Fuse base with HRC fuse link in the existing meter board and giving connections etc.

3

646

1938.18

... More
OD239526/2024-2025:Supply and fixing 63 A Fuse base with HRC fuse link in the existing meter board and giving connections etc.

12

331

3972.84

... More
OD239541/2024-2025:Supply and fixing 32 A Fuse base with HRC fuse link in the existing meter board and giving connections etc.

10

269

2696.1

... More
OD239538/2024-2025:Supply and fixing 63A, 2 way neutral link mounted on DMC/ SMC base in the existing box and giving connections etc. as required

2

208

416.46

... More
OD239522/2024-2025:Supply and fixing 32A, 2 way neutral link mounted on DMC/ SMC base in the existing box and giving connections etc. as required

6

129

776.94

... More
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.

5

394

1971.85

... More
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).

3

9605

28816.41

... More
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.

2

7611

15223.52

... More
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels

5

362

1812.25

... More
OD239558/2024-2025:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete.

120

79

9584.4

... More
4.1.8:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 62.5 mm depth X 2.0 mm thickness

75

716

53724

... More
4.1.9:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 62.5 mm depth X 2.0 mm thickness

15

800

12009.9

... More
4.1.10:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness

25

930

23265.5

... More
OD241524/2024-2025:Supply, Conveyance, Installation, testing and Commissioning of 82.5 KVA CPCB IV+ DG set with standard control panel on suitable CC foundation as per technical details given below: - Engine. a. Make of Engine: As specified in the accepted list of material b. Type of Engine Diesel Engine C. No. of cylinders 4 ln-lined. Method of cooling liquid cooling with radiator) e. Aspiration Turbo charged. Charge air Cooled f. Design Suitable for generator set application g. Required power for rated KVA & BHP at 1500 RPM under NTP Conditions or other BHP ratings Specified by the respective manufactures capable of delivering the required power for alternator Standard accessories of the diesel engine a. Fly wheel housing and Fly wheel to suit sin3le bearing alternator (Close coupled arrangement) b. Air cleaner c. Coolant kit d. Fuel Pump e. Electronic governor f. Fuel filter g. Lubricating oil filter h. Residential type exhaust silencer Engine Instrument Panel a. Starting switch with key or button b. Lubricating oil temperature gauge c. Lubricating oil pressure gauge d Water temperature gauge e. RPM Indicator with hour meter f. Battery charging ammeter Safety Controls for Engine a. Trip to low lubricating oil pressure b. Trip for low/ high Coolant temperature c. Providing necessary warning system and other safeties as contemplated in relevant ISS d. Fuel shut off facility at over speed Fuel Pipe Oil resistant flexible hoses & 25mm dia or nearest size MS pipe as per manufactures requirement for fuel line Alternator a. Make: As specified in the accepted list of material b. Type: Brush less type, Screen protected. Revolving field Self exited Generator c. Capacity :82.5 KVA/ 66 KW at 0.8 PF d. System of voltage: 3 phase ,4l5V e. Speed: 1500RPM: f. Voltage regulation band: +/-1.00% of rated Voltage g. Insulation: Class F/H i. AVR: Digital AVR shall be provided j. IP rating of enclosure: IP 23 j. THD: No Load <1.5%, non-distorting balanced linear load<5% k. Telephonic harmonic factor: less than 2% Safety Protection for Alternator AC Alternator protection for over/ Under Voltage, over/ Under frequency, over current. Short circuit and loss of AC sensing The alternator should confirm to IS/ IEC 60034-1. Routine tests as per relevant ISS shall be conducted and test reports of the same shall be furnished at the time of delivery. Fuel tank Integral type fuel tank of capacity not less than 150 litters/as per manufactures standards with drain plug. air vent, inlet arid outlet connections, level indicator and provisions for cleaning. Battery and battery Charger Required number of suitably rated fully charged 150 AH battery with leads and terminals including suitable type external Battery Charger for charging the battery from external mains as required as per manufactures requirements. The battery charger shall be suitable to charge the required number of batteries 12V/ 24V complete with transform, Rectifier charge rate selector switch. Indicating Ammeter & Voltmeter etc. This will be in addition to the battery charging alternator or dynamo fitted on the engine. Acoustic Enclosure a, The DG set shall be supplied along with specially designed company Fabricated (to be fabricated in the same company firm where the DG set delivered) acoustic enclosure to meet the stringent MOEF/ CPCB norms of 75 dB @1 m at 75% load under free field conditions b. Sufficient space and clearance shall be maintained inside the enclosure to have optimum serviceability c. Air inlet louvers shall be designed in such a way as to operate the set at rated load even at 50°C enclosure temperature d. The enclosure shall be 11 tank pre- treatment processed and UV resistant Powder coating of all parts to withstand extreme environments e. Hardware used shall be of only stainless steel make f. Insulation material shall conform to IS 8183 specifications Documents to be supplied a. Engine manual b. Spare parts book c. Warranty certificate d. Alternator manual & test certificate e. 1 set control wiring drawing Mounting Arrangement It shall be installed in the per-constructed concrete bed on a common MS fabricated base frame with AVM pads complying to relevant lS standards, lE rules end as per the direction of the Department officials. Exhaust System Exhaust piping: All MS pipes for exhaust line shall be conforming to the relevant IS. The work includes necessary cladding of exhaust pipe work using 50mni thick loosely hound resin (ABR) matters/ mineral wool/ Rock wool, density not less than 120 Kg/m3 and aluminium cladding (0.6mm thick) for the complete portion. The exhaust pipe work includes necessary supports, foundation etc. to avoid any load and stress on turbo charger/ exhaust piping. The exhaust piping Shall be run along the existing wall of the building duly clamped/ supported on independent structure. a) Exhaust system should create minimum back pressure. (b) Number of bends should be kept minimum and smooth bends should be used to minimize the back pressure. (c) Exhaust pipe inside the acoustic. Enclosure/ Generator room should be lagged with asbestos rope along with aluminium sheet cladding (d) When the tail end is horizontal, 45 Degree downward cut should be given at the end of the pipe to avoid rain water entry into exhaust piping. (e) When tail end is vertical there should be rain trip to avoid rain water entry. If rain Cap is used, the distance between the rain cap and exhaust pipe should be higher than the diameter of the pipe. (f) The exhaust outlet should be in the direction of prevailing winds and should not allow exhaust gases to enter the air inlet/ windows etc. (g) "Schedule B" MS pipes and long bend/ elbows should be used. Testing and commissioning The DG set shall be tested as per relevant IS standards. Block load testing shall also be conducted. The load required for testing shall be made available by the selected agency/ Contractor at his own expense. Warranty The DG set shall be guaranteed for 5 years from the date of commissioning from any defects in manufacturing. Any of the spares/ components which are found to be defective during this period shall be replaced immediately free of cost by the selected Agency/ Contractor.

1

1350176

1350176.97

... More
OD239525/2024-2025:Supply of High speed diesel (HSD) for DG set including conveyance,loading and unloading

200

101

20286

... More
OD239517/2024-2025:Supply and providing the following sizes of C class 100 mm MS pipe conforming to relevant IS specifications complete with heavy gauge specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/ wall/ any other mechanical support etc as required.

10

3148

31480.8

... More
OD239514/2024-2025:Supply and providing the following sizes of C class 125 mm MS pipe conforming to relevant IS specifications complete with heavy gauge specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/ wall/ any other mechanical support etc as required. (Exclusive of rate for mechanical support).

5

3455

17276.55

... More
OD239497/2024-2025:Supply, Conveyance, Installation, Testing and commissioning DOL type motor Controller having relay range 4- 6.5 A or suitable, 415V/ 50Hz with volt meter/Ammeter, indicators, single phasing preventer, Dry-run fault protection Micro-controller based etc. in sheet enclosure suitable for 3HP submersible motor pump set and giving necessary connections etc as required ( Make L&T MU-G10 DOL Controller/Techno commercial equivalent)

2

10376

20752.7

... More
OD239511/2024-2025:Supply, installation testing and commissioning of 3 phase, 415V, 50Hz,3 HP open well submersible motor pump set conforming to IS capable to discharge a total head range of 34-22 m, delivery size 50 mm having discharge range 0.5 - 7 lps and suspended on existing 2 run 10 mm stainless steel rope including fixing 80 sedulous ASTM delivery pipe connected one by one to the motor up to the bottom of the well/Sump using leak proof materials as required with necessary supports on both sides of the motor including giving connection as per the direction at site( Make CRI CSS-18 or Techno commercial equivalent approved by engineer in charge )

2

21334

42669.16

... More
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm

40

133

5350.8

... More
90.14.24.16:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.1 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.

2

331

663.22

... More
OD239521/2024-2025:Supply and laying 10 mm or nearest size stainless steel rope

12

156

1881.6

... More
OD239552/2024-2025:Supply and laying 12 mm or nearest size nylon rope

5

72

360.05

... More
OD239495/2024-2025:Supply and providing 50mm Forged Brass Ball Valve (Screwed) (Make Zoloto 1008B or Techno commercial equivalent)

2

3351

6702.9

... More
OD239498/2024-2025:Supply and providing 50mm ISI marked Bronze Horizontal Check Valve (NRV) (Screwed) (Make Zoloto 1038 or Techno commercial equivalent)

1

5130

5130.31

... More
OD239527/2024-2025:Supply, and jointing of reducing Tee ( 50mm x 32mm) or suitable size , ASTM 80 schedule uPVC with required leak proofing materials etc as required.

1

190

190.98

... More
OD239496/2024-2025:Supply, and jointing of 50mm size , ASTM 80 schedule uPVC Tee with required leak proofing materials etc as required.

1

197

197.8

... More
OD239561/2024-2025:Supply, and jointing of 50mm size , ASTM 80 schedule uPVC pipe bend with required leak proofing materials etc as required.

2

263

526.72

... More
OD239537/2024-2025:Supply, and jointing of 50mm size , ASTM 80 schedule uPVC flange adapter set with required leak proofing materials etc as required.

2

546

1093.62

... More
OD239510/2024-2025:Supply, laying and jointing of 50mm size , ASTM 80 schedule uPVC pipe with required specials as delivery pipe using required leak proofing materials etc as required.

10

459

4599.8

... More
OD239523/2024-2025:Supply and providing 32mm ISI marked Bronze Gate Valve Class-2 (Screwed) (Make Zoloto 1035A or Techno commercial equivalent)

1

3296

3296.58

... More
OD239493/2024-2025:Supply and providing 50mm ISI marked Bronze Gate Valve Class-2 (Screwed) (Make Zoloto 1035A or Techno commercial equivalent)

1

6721

6721.38

... More
OD239565/2024-2025:Supply,installation,testing and commissioning of 2KVA UPS single phase in and out with pf>=0.95 pure sine wave with automatic /manual bypass IGBT rectifier and inverter with battery over/under charge cutoff with Exide/equivalent battery of 2 hr backup.Numeric/Hycon/V Guard

1

81785

81785.92

... More
OD239542/2024-2025:Painting letters or figures with enamel paint as identification mark to SB, DB, panel board etc. as required 2.50 cm, 4 cm or 5 cm height

250

10

2545

... More
OD239545/2024-2025:Supply and providing 9L capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint FIRE mounted on MS angle frame work/wall bracket filled with fine sand, painted the bracket/floor stand including making good the damages, colour washing etc.as required.as per IS 2546

4

255

1020.44

... More
OD239501/2024-2025:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision

2

185

371.68

... More
OD239551/2024-2025:Supply and providing 2.5mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive.

10

1919

19194.3

... More
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

25

458

11454.75

... More
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

6

269

1619.34

... More
OD250100/2024-2025:supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct 800 cfm Exhaust blower with lovers

6

23810

142864.5

... More
16.12.1.1:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet

65

1175

76377.6

... More
16.12.1.2:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet

10

1379

13795.2

... More
OD249865/2024-2025:Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum, end grill etc as per standards and specification, 100mm dia.

10

2142

21429.7

... More
16.16.a:Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

2

6584

13168.86

... More
OD250391/2024-2025:Supply and providing 25A 2pole AC1 rated power contactor including giving connection etc as required.

6

1108

6653.64

... More
OD250392/2024-2025:Supply and providing 24 Hours analog timer for automatic ON/OFF operation of Exhaust fan and giving connection etc

3

2436

7309.59

... More
OD251255/2024-2025:Supply & installation of dust and vermin proof, box ( GS-MB- 3525) and to fix Contractor, Timer DP MCB, etc as required including fixing it on wall, making good the damages colour washing etc. as required.

3

2987

8961.03

... More
OD239564/2024-2025:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB / Fire & rescue service Department/ KSEB etc - First A3 Sheet

6

776

4657.5

... More
OD239569/2024-2025:Copying charges of Electrical/fire Drawing per A3 sheet additional copies

36

17

627.12

... More
SITC of Fire Protection System(Electrical work)

-

-

-

... More
90.17.1.9:Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head

1

250620

250620.27

... More
90.17.2.9:Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head

1

450909

450909.33

... More
90.17.3.3:Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) a. Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head

1

72696

72696.63

... More
OD239491/2024-2025:Supply ,installation ,testing and commissioning of electric driven terrace pump mounted on anti vibration pads consisting of following,complete in all respects as required. a) Horizontal type, centrifugal, End suction pump of CI body & bronze impeller with stainless steel shaft, mechanical seal at a flow of 450 lpm at 35 m Head conforming to IS 1520. b)Suitable HP Squirrel cage induction motor, TEFC type having synchronous speed of 1500 RPM & class- 'F' insulation suitable for operation on 415 V, 3 phase 50 Hz AC supply with IP55 protection for enclosureconforming to IS-325 c)MS fabricated common base plate ,coupling,coupling guard ,foundation bolts etc as required d)Suitable cement concrete foundation duly plastered .

1

72603

72603.71

... More
90.17.5.1:Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

215458

215458.25

... More
OD241180/2024-2025:Fabrication, Supply, Installation, Testing and commissioning of Fire Pump Control Panel for Terrace Pump consists of suitable size MCB Isolator/TPN SDU as incomer with DOL starter with single phase preventor suitable for upto 10HP pump without other protection complete with all acceessories and internal wiring required for automatic operation with selector switch auto/manual/OFF operation. LED type RYB phase indicating lamps, and pumps should have LED type ON, OFF indicating lamps, system controller to control operation of Terrace pump in sequence as per specification and commissioning as per the direction of department staff etc as required.

1

18474

18474.37

... More
90.17.7.1:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia

10

499

4997.4

... More
90.17.7.6:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia

15

1121

16819.35

... More
90.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia

125

1463

182987.5

... More
90.17.7.8:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia

10

1984

19840.6

... More
90.17.11.4:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia

2

4476

8952.48

... More
90.17.11.5:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia

9

6009

54089.91

... More
90.17.11.6:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia

2

8058

16116.08

... More
90.17.14.5:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia

3

9853

29561.82

... More
90.17.14.4:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia

1

6861

6861.37

... More
90.17.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b. 20 mm nominal internal dia gun metal globe valve & nozzle. c. Drum and brackets for fixing the equipmets on wall. d. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

3

7808

23425.95

... More
OD239486/2024-2025:"Supply, installation, testing and commissioning of weather proof hose cabinet having made of 2 mm thick MS Sheet and 4mm thick front glass door and locking arrangements suitable to accodmmodate 2 nos 15m long hose pipes and 1 No. branch pipe. The cabiner shall be painted to scarlet red colour outside and off white inside over a coat of primer and shall be suitably mounted on wall etc as required "

5

4800

24000

... More
90.17.16.2:Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)

10

3910

39104.3

... More
90.17.18.2:Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304)

5

1467

7339

... More
90.17.10.2:Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as requiredSingle headed Stainless steel

2

5499

10999.62

... More
90.17.9.2:Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel

3

5499

16499.43

... More
90.17.19.1:Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe

2

6028

12056.58

... More
OD239483/2024-2025:Supplying, fixing, testing and commissioning of 25 mm Air release valve as per IS:14845 as required

1

1813

1813.79

... More
90.17.20:Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

16178

16178.15

... More
OD251273/2024-2025:Supplying, fixing, testing and commissioning of 25mm Ball valve with bronze/gunmetal seat duly ISI marked complete with gaskets

3

784

2354.85

... More
90.17.22:Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required

4

1384

5538.64

... More
OD239481/2024-2025:Supply and providing pressure gauge in the existing system as required

2

1480

2961.08

... More
17.1.1:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

20

1265

25310.2

... More
17.1.2:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.

130

1364

177392.8

... More
17.1.4:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

3

473

1419.39

... More
17.1.7:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

3

572

1716.57

... More
17.1.9.3:Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.10 Zone

1

18817

18817.74

... More
17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

800

171

137376

... More
OD239476/2024-2025:Supply, Installation Testing and Commissioning of brass female threaded coupler draw out connection with 100mm

1

15580

15580.47

... More
90.17.8.7:Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm

10

1576

15761

... More
OD239473/2024-2025:Suply and providing emergency fire escape lighting system consisting 2 nos lamp ,7 AH FMF battary charging unit ,exit sign display etc in MS enclosure

6

4837

29025.9

... More
OD239479/2024-2025:Supplying and installing in position LED "EXIT" sign boards of suitable size with battery backup.

6

2601

15608.46

... More
OD239489/2024-2025:Supply and installing in position laminated sheet of " FIRE EVACUATION PLAN " of suitable size fixed on wall & necessary accessories to fix the plan on wall.

6

2652

15916.86

... More
OD239480/2024-2025:Supply & erection of Glow Sign Board made of 3mm thick PVC foam board for each floor 12" x 4" (appropriate places)

20

524

10495.6

... More
OD251306/2024-2025:Supply & erection of Glow Sign Board made of 3mm thick PVC foam board for Assembly Point sign board 16" x 16"

1

367

367.69

... More
OD239466/2024-2025:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB / Fire & rescue service Department/ KSEB etc - First A3 Sheet

8

776

6210

... More
OD239464/2024-2025:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB / Fire & rescue service Department/ KSEB etc - Each Additional A3 Sheet

32

17

557.44

... More
OD239490/2024-2025:Supply and installation of ABC type fire extinguisher of 5 Kg. Capacity with stored pressure type complete with installation brackets with ISI mark

8

3346

26770.24

... More
OD239467/2024-2025:Supply and installation of CO2 type fire extinguisher of 4.5 Kg. Capacity with stored pressure type complete with installation brackets with ISI mark

4

9056

36224.88

... More
OD239474/2024-2025:Supply & installation of 5Kg Clean Agent HCFC 123(Stored pressure) type fire extinguisher pressurized with Argon gas at 15 bar. Design, construction and testing as per IS:15683 with fire rating 1A 8B, body hydrotested at 35bar,operating temperature -30oC to +55oC, external epoxy powder coating with PO red shade, supplied with standard accessories.

3

21363

64091.97

... More
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

20

1089

21793.4

... More
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.

0.5

8181

4090.87

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

10

99

999

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

10

108

1081.6

... More
90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size

3

152

457.83

... More
90.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm

5

97

489.1

... More
90.6.5.5:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 2.50 sq mm

5

112

562.8

... More
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm

10

133

1337.7

... More
90.6.6.6:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.16 sq mm

10

482

4821.3

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

20

63

1272.6

... More
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

10

98

982.7

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

8

27

216.16

... More
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

4

27

110.84

... More
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

1

440

440.03

... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

1

262

262.1

... More
SITC of Passenger Lifts(Electrical work)

-

-

-

... More
OD241081/2024-2025:Supply, Installation, Testing and Commissioning of 13 passenger capacity machine room less gear less lift with the following specification including all required standard features.1. Type of Lift: 13 Passenger capacity, Gearless 2. Load / Persons : 884 Kg. / 13 persons 3. Rated speed :1 M/Sec. 4. Travel: 7.2 Mtr (Approx.) 5. No. of floor and entrance served: 3 stops and openings 6. No. of floor served: Three floors 7. Method of control: Microprocessor based V3F with ARD system. 8. Size of lift well :2220 mm X 3070 mm 9. Car entrance: As per IS or as per Barrier free rule. 10. Leveling accuracy: As per IS 11. Car door opening: As per IS 12. Drive: Variable voltage variable frequency(V3F) 13. Operation: Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel with back side upper half portion mirror finish (SS304, make: Tata/Jindal) cabinet with Scratch Proof Stainless steel door with 1/2 glass, Stainless steel mirror finish ceiling, Aluminum 3mm minimum thickness anti-skid flooring, fan with timer cut-off, push to talk, LED display, LED light, three side hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance: Automatic center/Telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra-red light curtains and half framed glass door 16. Call and position indicators: Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply: 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infra-red door opening system: To be provide for entire length of the door 19. Automatic Rescue Device: Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four successive rescue operation at full load. The rescue operation should act within 10 seconds of power failure 20. Regulation :350V 450V (SMPS based) 21. Indication in the car: a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Nonstop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel: Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests: At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel (machine and rope ending point support should extended to existing well wall side using suitable I/C section channels as per the direction of department staff) f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit.

1

2625135

2625135.19

... More
OD241091/2024-2025:Supply, Installation, Testing and Commissioning of 10 passenger capacity machine room less gear less lift with the following specification including all required standard features.1. Type of Lift: 10 Passenger capacity, Gearless 2. Load / Persons : 680 Kg. / 10 persons 3. Rated speed :1 M/Sec. 4. Travel: 7.2 Mtr (Approx.) 5. No. of floor and entrance served: 3 stops and openings 6. No. of floor served: Three floors 7. Method of control: Microprocessor based V3F with ARD system. 8. Size of lift well :2220 mm X 2640 mm 9. Car entrance: As per IS or as per Barrier free rule. 10. Leveling accuracy: As per IS 11. Car door opening: As per IS 12. Drive: Variable voltage variable frequency(V3F) 13. Operation: Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel with back side upper half portion mirror finish (SS304, make: Tata/Jindal) cabinet with Scratch Proof Stainless steel door with 1/2 glass, Stainless steel mirror finish ceiling, Aluminum 3mm minimum thickness anti-skid flooring, fan with timer cut-off, push to talk, LED display, LED light, three side hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance: Automatic center/Telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra-red light curtains and half framed glass door 16. Call and position indicators: Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply: 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infra-red door opening system: To be provide for entire length of the door 19. Automatic Rescue Device: Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four successive rescue operation at full load. The rescue operation should act within 10 seconds of power failure 20. Regulation :350V 450V (SMPS based) 21. Indication in the car: a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Nonstop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel: Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests: At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel (machine and rope ending point support should extended to existing well wall side using suitable I/C section channels as per the direction of department staff) f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit.

1

2490677

2490677.05

... More
LAN(Electronics Work)

-

-

-

... More
OD249189/2024-2025:SITC of sheet steel, phosphatised and painted, dust and vermin proof Wall Mount 6U Rack for switches, Patch panels and accessories including cable manager(x2), AC Distribution box(x1), cooling fan(x2) and hardware mounting kit. Conforms to DIN41494 Preferred Make: VALRack/NetRack/Rittal

7

6504

45532.76

... More
OD251569/2024-2025:SITC of sheet steel, phosphatised and painted, dust and vermin proof Wall Mount 9U Rack for switches, Patch panels and accessories including cable manager(x2), AC Distribution box(x1), cooling fan(x2) and hardware mounting kit. Conforms to DIN41494 Preferred Make: VALRack/NetRack

1

9640

9640.73

... More
OD251570/2024-2025:SITC of 17U/600X600 Rack/Welded/Floor Mount, Glass Door/lSU/Floor Mount, , Server /IT Rack mount power distribution unit, lPh, 230V, 8A, 50/60Hz, 1U standard with 6 X Indian Round Pin SA, Inlet Plug type 6A Indian Round Pin, 8A Fuse - POU Rating l.8KVA/Side feed-1.SMt/ Black, ITE /Server Rack Air module/90CFM, Hardware-Kit (Pack of 10). Preferred Make. Rittal/Netrack/Valrack

1

15448

15448.23

... More
OD249191/2024-2025:Supply, Store, Installation, Testing and Commissioning of Cat-6 U/UTP patch panels shall modular style patch panel with 24 port per 1Rack unit, Straight and angled option shall be available as per the site requirement. Panel should support the strain relief bar in the back of the panel. Bar should have the cable holders with Velcro to hold the cables in place. Approved Make: Panduit/Commscope/Nexans/R&M, Molex

9

5088

45798.3

... More
OD249192/2024-2025:SITC of CAT-6 , 1 meter Patch code for interconnecting Patch panel and Switch.4 pair 26 AWG stranded copper wire, Pre-terminated with RJ45 plugs, RoHS Compliant. Preferred Make: Molex/AMP

140

197

27654.2

... More
OD249193/2024-2025:SITC of CAT-6 , 2 meter Patch code for interconnecting information outlets and computers.4 pair 26 AWG stranded copper wire, Pre-terminated with RJ45 plugs, RoHS Compliant. Preferred Make: Molex/AMP

140

209

29279.6

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

140

290

40682.6

... More
OD249194/2024-2025:SITC of CAT 6 RJ 45 modular Keystone jack in the existing front plates and giving necessary connections as required (RoHS) Preferred Make: AMP/Molex

140

293

41024.2

... More
OD251572/2024-2025:SITC of 16 Port 10GE SFP+L2+Manged switch having 16 X 10Gbps SFP+ ports, 1 X USB A and 2XUSB C console ports, 320Gbps switching capacity, Built-in IT web GUI, console, telnet, and SSH options etc.., Detailed specification attached in Annexure1 Preffered Make: Netgear/Cisco/Juniper

1

148074

148074

... More
OD249195/2024-2025:26 port Rack mountable Smart managed Gigabit Switch with min 24 10/100/1000 RJ45 ports and 2 10G SFP ports having Min 48 Gbps bandwidth, Min 8K MAC Address table size, should support IEEE 802.1D Spanning Tree Protocol,100 VLAN Spport,VLAN tagging (Min 64 static VLAN group), Port based VLAN(min 24 Group),IGMP Snooping ,DHCP Client support etc Certifications :- CE, FCC,EN 55024, UL Preferred Model: Cisco, Hp, Netgear or equivalent

5

24133

120666.4

... More
OD251573/2024-2025:SITC of 16-Port Gigabit L2 and Managed Switch with 2 10GE SFP Slots having 24&times; 10/100/1000 Mbps RJ45 Ports, 4&times; 10G SFP+ Slots, 1XRJ45 and 1Xmicro USB console ports, 36Gbps switching capacity, 16K MAC Address Table, Web based GUI/Telnet/CLI management options etc.., Preffered Make: Netgear/TP-Link//HP

5

15070

75353.75

... More
OD251574/2024-2025:SITC of 24 Port , 0S2, 1U Rack mount unit Fiber LIU with shelf made of metal with powder coated ,loaded with LC /SC type (Aqua color), pigtail loaded, hinged splice tray and cable spool and other splicing I accessorie., Preferred Make : Molex,Belden,Panduit.

1

24598

24598.5

... More
OD251578/2024-2025:Supply,Installation,Testing and Commissioning of Fiber Optic patch Cord (LC/UPC- LC/UPC), Duplex, Single mode OS2,Cable Sheath Material: LS0H,Retention Strength: 100N,Insertion Loss: 0.30dB,Attenuation: @ 1310nm <0.4dB/km , Preferred Make : Molex/Belden/Panduit

15

1401

21016.35

... More
OD251580/2024-2025:SITC of SFP Module-10G Base-LX Fiber SFP,LC duplex connector,1310 nm, for distances up to 10 km,Single Mode Fiber,ROHS Compliant,Compliant with SFP Transceiver MSA specification,Compliant with Specifications for IEEE 802.3z/10G Ethernet,Compliant with Industry Standard RFT Electrical Connector and Cage,Single + 3.3V Power Supply and TTL Logic Interface,EEPROM with Serial ID Functionality,&quot;Laser Class 1 Product which comply with the requirements of IEC 60825-1 and IEC 60825-2&quot. Approved make : Netgear/TP-Link/HP/ Syrotech/Cisco

20

7197

143942

... More
OD251598/2024-2025:SITC of 2000 VA pure sine wave home ups/inverter including conveyance and all other charges woth the minimum features specifications as below. DSP Based, ASIC Technology, Power factor controlled Battery Charger, LCD Display- displaying state of battery voltage and charge, AC mains input voltage, Short circuit trip, Battery low trip, AC mains fuse blown, etc., Electrolylte level sensor indicator: For indicating battery water level low, protection: High quality protection built up in the PCB, 2 Year Manufacturer Warranty including DB to Inverter necessory Wiring Recomended Model: Exide/Hykon/APC

1

16924

16924.55

... More
OD251599/2024-2025:SITC of Inverter battery having minimum rating 12V 120 Ah Conforms to IS133969-1992, Tower type Design, Electrolyte level indicator, Ironcard@Tubular technology, Commonside vending, etc including conveyance and all other charges minimum 3 year Manufacturer warranty Recomended Model: Exide

2

13207

26415.5

... More
CCTV(Electronics Work)

-

-

-

... More
OD251582/2024-2025:SITC of sheet steel, phosphatised and painted, dust and vermin proof Wall Mount 6U Rack for switches, Patch panels and accessories including cable manager(x2), AC Distribution box(x1), cooling fan(x2) and hardware mounting kit. Conforms to DIN41494 Preferred Make: VALRack/NetRack

1

6504

6504.68

... More
OD251583/2024-2025:SITC of 16-Port Gigabit PoE Switch with 2-SFP port, Power budget of 250W, 20Gbps forwarding capacity, 4K MAC Address Table, 10BASE-T/100BASE-TX/1000BASE-T Interface options, conforming to FCC Class A, CE Class A Emission, RoHS compliant. Rack mountable, QoS, Vlan, IGMP & LAG. Preffered Make: TP-Link tl-sg1218mpe/D-Link or eqvt.

2

20961

41923.54

... More
OD249196/2024-2025:SITC of Enterprise series 40 CH NVR having following minimum specifications: Video Input: 40 Channel, Max Resolution: 12MP, Bandwidth: Income 200Mbps; Outgoing 200Mbps, HDMI/VGA Output: HDMI 1-ch, 3840×2160, 2560×1600, 2560×1440, 1920×1080, 1280×720, 800×600, 1024×768, 1366×768, 1440×900, 1280×800 VGA 1-ch, 1920×1080, 1280×720, 800×600, 1024×768, 1366×768, 1440×900, 1280×800, Screen Split : 1/3/4/6/8/9/10/13/16/20/25/36/40/64, Audio Output: 1x RCA, Decoding Format: IH+265/H.265/H.264, Recording Resolution: 12MP/8MP/6MP/5MP/4MP/3MP/1080P/UXGA/720P/VGA/4CIF/DCIF/2CIF/CIF/QCIF, Preview Capability: 3x12MP, 4x8MP, 4x6MP, 5x5MP, 8x4MP, 9x3MP, 16x1080P, 32x720P, 40x4CIF, Records Encryption: Yes, SATA: 4 SATA interface for 2 HDDs, Capacity: Up to 10TB for each HDD, Network Interface: 2xRJ45 self-adaptive 10/100/1000 Mbps network interface, USB Interface: 1xUSB 2.0, 1xUSB 3.0, Protocol: TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, PPPoE, NTP, UPnP, SMTP, IGMP, QoS, IPV4, IPV6, Multicast, ARP, UDP, SNMP, SSL, Telnet, RTMP, NFS, System Compatibility: ONVIF (PROFILE S/T/G), Web Version: Web6, Language: English, Operating Conditions: -10°C~55°C, 10%~90% RH, Power Supply: 100~240V AC, 50~60 Hz, Consumption (without HDD): ≤25W (without HDD), Chassis: 1.5U Preferred Make: Honeywell/TYCO Illustra pro/Samsung Hanwha/Mobotix/Bosch/Pelco. - 5 Years onsite Warranty

1

43463

43463.15

... More
OD249197/2024-2025:Supply, Store, Installation, Testing and Commissioning of Cat-6 U/UTP patch panels shall modular style patch panel with 24 port per 1Rack unit, Straight and angled option shall be available as per the site requirement. Panel should support the strain relief bar in the back of the panel. Bar should have the cable holders with Velcro to hold the cables in place. Approved Make: Panduit/Commscope/Nexans/R&M, Molex

2

5088

10177.4

... More
OD249198/2024-2025:SITC of 8TB Surveillance Internal Hard Drive - 7200 RPM Class, SATA 6 GB/S, 256 MB Cache, 3.5", Etc or Better specification. Make - Western Digital/Seagate/Samsung.

2

22356

44712

... More
OD251600/2024-2025:SITC of 50 inch 4KSmart Business LED Television sets having the following minimum specifications. Resolution: 3840 X 2160, Brghtness: 250nits, USB port: minimum 2 nos, HDMI/Optical Component Connectivity, Contrast Ratio:4700:1, Viewing Angle(H/V): 178/178, Response Time:8ms, The LED TV set shall have Built in Wifi,Bluetooth support, Built in speaker, PC/DVD component connectivity, remote control and wall bracket,Neccessory length HDMI Cable etc complete,3 Years Full warranty and shall be complete as per manufacturer specification Approved Make: Samsung/NEC/Sony/LG

1

54992

54992.45

... More
OD249201/2024-2025:Supply, installation, testing, and commissioning of UL Listed, Tool Free CAT 6 Field Termination Plug , suitable for 22- 26 AWG bare copper conductor, 5 reterminations, conforming to the standards ANSI/TIA-568.2-D , IEEE 802.3, and RoHS Complaint Make: AMP/Molex/CommScope

25

306

7658.25

... More
OD249209/2024-2025:SITC of 2MP Fixed Color Vision Bullet Camera having following minimum specifications - Image Sensor: 1/2.8” CMOS, Signal System: PAL/NTSC, Min. Illumination: Color: 0.0008Lux@ (F1.6, ACG ON), 0Lux with LED on, Shutter Time: 1s to 1/100,000s Day & Night Dual IR Cut Filter with Auto Switch, Wide Dynamic Range: 120dB, Angle Adjustment: Bracket, pan 0~360°, tilt 0~75°, roate 0~360°, Lens Type: Fixed 4mm, Lens Mount: M12, Aperture: F1.6, Fixed FOV: Horizontal field of view: 83.3° (4mm), White LEDs/Warmlights: 2, Video Compression: IH+265/H.265/H.264, Video Bit Rate: 32Kbps~6Mbps, Audio Compression: G.711A/G.711U/ADPCM_D, Audio Bit Rate: 8K~48Kbps, Max. Resolution 1920x1080 Main Stream PAL: 25fps (1920x1080, 1280x720, 704x576, 640x480) NTSC: 30fps (1920x1080, 1280x720, 704x480, 640x480) Sub Stream PAL: 25fps (704x576, 704x288, 640x360, 352x288) NTSC: 30fps (704x480, 704x240, 640x360, 352x240) Image Setting Saturation, brightness, contrast, sharpness, adjustable by client software or web browser Image Enhancement BLC/3D DNR/HLC, Alarm Trigger Motion Detection, Mask Alarm, IP Address Conflict Video Analytics Tripwire, Perimeter, Protocols TCP/IP, HTTP, FTP, DHCP, DNS, DDNS, MULTICAST, IPV4, NTP, UDP, Telnet, ICMP, RTP, RTSP, UPnP, Communication Interface 1 RJ45 10M/ 100M self-adaptive Ethernet port Audio I/O Mic in Reset Button: Yes, On-board storage: Built-in MicroSD card slot, up to 512 GB, Protection IP67, Lightning protection, surge protection and voltage transient protection 5 years warranty Preferred make: Honeywell Impact/Hanwha/Bosch/Mobotix

14

8411

117767.44

... More
OD249214/2024-2025:SITC of 2MP Fixed Color Vision Dome Camera having following minimum specifications - Image Sensor: 1/2.8” CMOS, Signal System: PAL/NTSC, Min. Illumination: Color: 0.0008Lux@ (F1.6, ACG ON), 0Lux with LED on, Shutter Time: 1s to 1/100,000s Day & Night Dual IR Cut Filter with Auto Switch, Wide Dynamic Range: 120dB, Angle Adjustment: Bracket, pan 0~360°, tilt 0~75°, roate 0~360°, Lens Type: Fixed 4mm, Lens Mount: M12, Aperture: F1.6, Fixed FOV: Horizontal field of view: 83.3° (4mm), White LEDs/Warmlights: 2, Video Compression: IH+265/H.265/H.264, Video Bit Rate: 32Kbps~6Mbps, Audio Compression: G.711A/G.711U/ADPCM_D, Audio Bit Rate: 8K~48Kbps, Max. Resolution 1920x1080 Main Stream PAL: 25fps (1920x1080, 1280x720, 704x576, 640x480) NTSC: 30fps (1920x1080, 1280x720, 704x480, 640x480) Sub Stream PAL: 25fps (704x576, 704x288, 640x360, 352x288) NTSC: 30fps (704x480, 704x240, 640x360, 352x240) Image Setting Saturation, brightness, contrast, sharpness, adjustable by client software or web browser Image Enhancement BLC/3D DNR/HLC, Alarm Trigger Motion Detection, Mask Alarm, IP Address Conflict Video Analytics Tripwire, Perimeter, Protocols TCP/IP, HTTP, FTP, DHCP, DNS, DDNS, MULTICAST, IPV4, NTP, UDP, Telnet, ICMP, RTP, RTSP, UPnP, Communication Interface 1 RJ45 10M/ 100M self-adaptive Ethernet port Audio I/O Mic in Reset Button: Yes, On-board storage: Built-in MicroSD card slot, up to 512 GB, Protection IP67, Lightning protection, surge protection and voltage transient protection 5 years warranty Preferred make: Honeywell Impact/Hanwha/Bosch/Mobotix

11

7831

86143.31

... More
OD249217/2024-2025:SITC of Warning sign boards-You Are Under Surveillance Of CCTV (BRUSH STEEL) SILVER Self adhesive Sign 8 inch by 10 inch, reputed make.

10

1161

11615

... More
OD251605/2024-2025:Supply and installation of Laptop computer with 13th Generation Intel® Core™ i5 processor Windows 11 Home 39.6 cm (15.6) diagonal, FHD display with Intel® Iris® X? Graphics16 GB DDR4-3200 MT/s RAM512 GB SSD Solid State Drive720p HD camera, Spill resistant, backlit keyboard with numeric keypad, Fingerprint reader Warranty: 5 Year for laptop and 3 year for battery

1

65601

65601.64

... More
Cabling(Electronics Work)

-

-

-

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1500

99

149850

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

860

108

93017.6

... More
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

5499

58

321196.59

... More
OD251584/2024-2025:Supply, laying, testing of 6 Core Single Mode Outdoor Loose Tube Armoured 9/125μm OS2 Type Optical, Low Water Peak Fiber Indoor/Outdoor Rated with Loose tube diameter : 1.8mm (Nominal),Outer Sheath : Anti Rodent, Anti Termite and UV HD Polyethylene - Black,Overall Cable Dimensions (Nominal) : 10.0 ± 1mm,Mass (Nominal) : 80 kg/km± 10%,Max. Tensile Strength-Short Term: 1500N,Min. Crush Resistance- : 2000N/10 cm,Optical Performance Max. Attenuation; At 1310 nm : 0.35dB/km At 1550 nm : 0.20dB/km,RoHS Compliant. Preferred Make : Molex/Belden/Panduit.

500

77

38655



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.