Public Works Department Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Public Works Department - PWD Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jun 2024
Closing Date18 Jun 2024
Tender Amount₹ 65,89,39,683 
Notes
Download

Costs

Summary

General-court Complex Kollam-home Department-judiciary

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

16.8

29614

1762.74

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

9270

2021323

218.05

... More
OD250946/2023-2024:Providing Z steel sheet pile of size 400x185x7.5/8.5 driving down vertically in lines and levels interlocking with adjacent piles with suitable ple driving unit and all accessories including all labour hire charges etc.complete as per the direction of departmental officers at site.

815

920167

1129.04

... More
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

480

139185

289.97

... More
OD250699/2023-2024:Pumping or bailing out water using well point system (2 months continuous pumping) including boring of holes and all installation costs, labor, pump set, diesel, oil charges, riser pipe, header pipe etc all complete. Quantity to be measured as no of well points.

300

2191038

7303.46

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

1127.83

7830541

6943.04

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1633.22

557940

341.62

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

19480

12896151

662.02

... More
OD251368/2023-2024:Random rubble masonry with hard stone in foundation up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)

373.13

2684062

7193.41

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

891087.98

89242461

100.15

... More
OD174344/2023-2024:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum and excess cement cost is not payable. Excess/less cost of cement as per mix design is not payable or recoverable. All work up to plinth level

5983.82

57888711

9674.21

... More
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

15.98

187157

11709.05

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

316.7

231409

730.69

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

9246.5

2435711

263.42

... More
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

455.83

244197

535.72

... More
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.

2040.75

614388

301.06

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

9084.48

7993067

879.86

... More
5.9.9:Centering and shuttering including strutting, etc. and removal of form for:Arches, domes, vaults up to 6m span

84.98

174580

2054.49

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

12811.46

10647476

831.09

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

846.36

631655

746.32

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

2059.9

427964

207.76

... More
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

1047.9

963575

919.53

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1061525.08

106311736

100.15

... More
OD174346/2023-2024:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum and excess cement cost is not payable. Excess/less cost of cement as per mix design is not payable or recoverable. All work above plinth level up to v level

5001.29

56801623

11357.39

... More
OD37075/2024-2025:Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/200mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

3877.88

30864953

7959.24

... More
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

42.08

332659

7904.84

... More
OD174347/2023-2024:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 10cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

104.53

638389

6107.24

... More
OD39410/2024-2025:Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.80 sqm).

1299.9

10884062

8373

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

1349.2

1617380

1198.77

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

7918.35

1742353

220.04

... More
9.147F.4:Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)

2.52

23495

9323.48

... More
9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

550.4

448735

815.29

... More
9.122.2:Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

165.12

778596

4715.34

... More
21.18:Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

40.56

272228

6711.75

... More
OD40967/2024-2025:Providing &fixing pressed steel door frames conforming to IS:4351,manufactured from TATA Galvano/approved equivalent galvanised plain steel sheet of 1.2 mm thickness,including hinges,jambs,lock jamb,bead and if required angle threshold of mild steel angle of section 50x25mm ,or base ties of 1.25mm pressed,mild steel welded or rigidly fixed together by mechanical means,including stainless steel butt hinges 125x2.5mm thick with mortar guards ,lock strike-plate and shock absorbers as specified and applying a coat of approvedsteel primer after pre-treatment of the surface as directed by Engineer-in -charge :-Profile B-Fixing with adjustable lugs with split end tail to each jamb

1560

768471

492.61

... More
OD40968/2024-2025:Providing &fixing double leaf pressed steel door shutter conforming to IS:4351,manufactured from TATA Galvano/approved equivalent galvanised plain steel sheet of 1.2 mm thickness,,panelling with embossed and stiffened sheet assembled by welding and applying a coat of approved steel primer after pre-treatment of the surface including all hardwares such as stainless steel aldrops,stainless steeel tower bolts and stainless steel handles as directed by Engineer-in -charge :-Profile 75x30mm for shuttter frame

701.64

3691363

5261.05

... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

3.12

486625

156119.69

... More
9.5.1.2:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.30 mm thick shutters

7.82

31181

3987.41

... More
9.7.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

4.32

15243

3528.48

... More
9.74.1:Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm

16

7169

448.11

... More
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

24

5158

214.92

... More
50.9.15.2:Supplying and fixing 300 mm Aluminium aldrop

4

756

189.04

... More
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop

500

85810

171.62

... More
OD174352/2023-2024:Supplying, filling, spreading & leveling stone chips of size range 5 mm to 10 mm, in sunken portion

53.91

78520

1456.56

... More
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

507.09

283123

558.33

... More
22.3:Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of : i) I course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) III course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/ sqm.

132.16

111843

846.27

... More
OD174353/2023-2024:Providing and fixing stone wall cladding tiles (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 15-29 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

921.96

1957404

2123.09

... More
9.9.1.1:Providing and fixing glazed shutters for door, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. Pressed butt hinges bright finished of required size with necessary screws. Second class teak wood35 mm thick

37.44

195480

5221.17

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

27448.04

8783922

320.02

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

15851.52

4321441

272.62

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

2046.87

836697

408.77

... More
13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

20416.21

2818866

138.07

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

33294.2

2396516

71.98

... More
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

4833.24

954709

197.53

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

33294.2

5136295

154.27

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1276.61

1577313

1235.55

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

215.62

239680

1111.57

... More
11.41.4:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm

10975.1

32894575

2997.2

... More
11.47.4:Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1000x1000 mm

989.04

3244539

3280.48

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

4374

3018541

690.11

... More
5.30:Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

3273.2

231153

70.62

... More
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

57.77

3512

60.8

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

3475.61

506535

145.74

... More
16.45:Providing and fixing in position pre- moulded joint filler in expansion joints.

8100

29889

3.69

... More
21.7.2:Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Powder coated aluminium sheet 2.5 mm thick ( minimum thickness of powder coating 50 micron)

28

20629

736.76

... More
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

4074.95

788380

193.47

... More
12.45.3:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

3773.43

5820281

1542.44

... More
50.12.2.5:Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

341.62

314710

921.23

... More
16.90:Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

72

166970

2319.03

... More
OD174357/2023-2024:Providing and fixing DLP board of size 90cm x 60cm in 4mm AC panel with HD Vinyle print with required matter printed including all cost of fabrication, transportation to site and fixing as per the direction of Engineer in charge

1

1551

1551.04

... More
OD174358/2023-2024:Supplying fabricating and fixing Stainless Steel embossed letter English font of size 30 cm height to the name board with bolts and nuts , drilling and fixing to the panel with synthetic resin adhesive to correct lines and levels as per the direction of the departmental officers

100

133573

1335.73

... More
OD174359/2023-2024:Supplying fabricating and fixing Stainless Steel embossed letter English font of size 20 cm height to the name board with bolts and nuts , drilling and fixing to the panel with synthetic resin adhesive to correct lines and levels as per the direction of the departmental officers

100

98728

987.28

... More
OD174360/2023-2024:Supplying fabricating and fixing Stainless Steel embossed letter Malyalam font of size 30 cm height to the name board with bolts and nuts , drilling and fixing to the panel with synthetic resin adhesive to correct lines and levels as per the direction of the departmental officers. Material

100

150995

1509.95

... More
OD174361/2023-2024:Supplying fabricating and fixing Stainless Steel embossed letter Malayalam font of size 20 cm height to the name board with bolts and nuts , drilling and fixing to the panel with synthetic resin adhesive to correct lines and levels as per the direction of the departmental officers

100

127765

1277.65

... More
13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

302.94

436

1.44

... More
8.12:Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge. a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

487.02

1446371

2969.84

... More
8.3.2:Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

1050.4

473919

451.18

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

13401.8

3977384

296.78

... More
OD40570/2024-2025:Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand ) etc. complete excluding plastering of the jambs, sills and soffits.25 mm thick

491

216835

441.62

... More
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

3800

3916166

1030.57

... More
SUMP and PUMP ROOM(Civil work)

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

302.4

91497

302.57

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

190.4

20635

108.38

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

287.51

75736

263.42

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

17.13

118934

6943.04

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

221.14

75545

341.62

... More
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

10.36

9526

919.53

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

24.73

16371

662.02

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

25.76

21408

831.09

... More
OD174362/2023-2024:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum and excess cement cost is not payable. Excess/less cost of cement as per mix design is not payable or recoverable. All work below plinth level .

104.14

1007452

9674.21

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

57.5

15675

272.62

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

15620.7

1564413

100.15

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

114.2

46681

408.77

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

112.7

65477

580.99

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

75

33585

447.81

... More
OD174363/2023-2024:Supply and fixing 2HP Submersible motor with pump set Kera

1

15324

15324.29

... More
18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

2

1192

596.21

... More
18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

2

1394

697.05

... More
18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

2

1627

813.55

... More
OD174364/2023-2024:Providing and fixing DN15 Multifunctional float valve (ball-cock) for water storage tank of approved quality (screwed end) :25 mm nominal bore (valve, spindle and ball etc)

1

3136

3136.05

... More
OD174365/2023-2024:Supply and fixing of Double flanged cast iron pipe (8'' dia 60 cm length) using middle wall of the sump for water passing through the both sump

2

6436

3218.31

... More
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

154.1

285672

1853.81

... More
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

95

170953

1799.51

... More
11.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

487.8

141237

289.54

... More
11.50:Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles

487.8

6448

13.22

... More
50.6.3.1:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete

7.21

51112

7089.17

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

411.27

131614

320.02

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

48.65

3501

71.98

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

48.65

7505

154.27

... More
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

51.8

10232

197.53

... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.07

10147

156119.69

... More
9.5.1.2:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.30 mm thick shutters

2.52

10048

3987.41

... More
septic tank(Civil work)

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

267

80786

302.57

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

90

9754

108.38

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

244.2

64327

263.42

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

339.4

115945

341.62

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

13.25

91981

6943.04

... More
OD174340/2023-2024:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum and excess cement cost is not payable. Excess/less cost of cement as per mix design is not payable or recoverable. All work below plinth level .

83.42

807061

9674.21

... More
50.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

200

181616

908.08

... More
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

100

17565

175.65

... More
OD174341/2023-2024:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 200x200x200 mm dia Tee

50

17969

359.39

... More
50.6.5.1:Hollow block masonry using pre cast blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

12.96

69832

5388.29

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

12513.6

1253237

100.15

... More
Water supply &Sanitary (Phase- I & II)(Civil work)

-

-

-

... More
19.7.1.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

150

1961664

13077.76

... More
17.32.4:Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm

150

321370

2142.47

... More
17.4.2:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern

120

1104888

9207.4

... More
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

188

12612

67.09

... More
50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

188

24133

128.37

... More
50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

200

256170

1280.85

... More
50.18.8.3.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2

300

134118

447.06

... More
50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall

550

167403

304.37

... More
17.2.2:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat and lid

188

1158961

6164.69

... More
17.7.1:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

188

696145

3702.9

... More
18.15.2:Providing and fixing brass bib cock of approved quality :20 mm nominal bore

188

73594

391.46

... More
17.28.2.1:Flexible pipe32 mm dia

188

22795

121.25

... More
18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

50

33118

662.37

... More
18.19.6.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 80 mm nominal boreHorizontal

10

34666

3466.62

... More
18.30.3:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:125 mm diameter pipe

20

6676

333.83

... More
18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

30

24406

813.55

... More
50.18.7.3.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge 25 mm dia 12 Kgf/cm2 - Internal work - Exposed on wall

650

186732

287.28

... More
50.18.9.16.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall

730

314586

430.94

... More
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

300

52695

175.65

... More
50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee

520

97983

188.43

... More
50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow

550

73051

132.82

... More
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

500

80930

161.86

... More
50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2

450

306742

681.65

... More
50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

590

252183

427.43

... More
50.18.9.7.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2

600

184854

308.09

... More
50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2

600

288738

481.23

... More
50.18.9.3.2:Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2

300

65667

218.89

... More
50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

200

89108

445.54

... More
18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

188

119942

637.99

... More
OD174369/2023-2024:Providing and fixing stainless steel grating of approved quality and colour. Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating

188

87126

463.44

... More
50.18.9.13.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall

300

89172

297.24

... More
50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

300

99504

331.68

... More
50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall

300

81195

270.65

... More
50.18.9.19.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall

450

150327

334.06

... More
50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling

100

11192

111.92

... More
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

188

23441

124.69

... More
50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow

200

12986

64.93

... More
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend

200

16006

80.03

... More
50.18.9.20.6:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee

250

23747

94.99

... More
50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl

188

14498

77.12

... More
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow

200

21686

108.43

... More
50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow

150

15916

106.11

... More
OD174370/2023-2024:Lettering with vinyl sticker type letter of standard size, font and colour as specified by the Engineer in charge.

20

71

3.58

... More
OD174371/2023-2024:Providing and fixing office signage boards with good quality 4mm thick ACP sheet af approved colour as directed by the Engineer in charge and indicating necessary signs and lettering etc. with vinyl sticker type letters and necessary provisions for hooks/chains/ rings/screws etc including cost of materials, conveyance and fixing charges etc complete

9

22801

2533.5

... More
OD174372/2023-2024:Providing and fixing braille directional signage with ADA Braille sign in Polymer sheet with tactile characters and picture. 2 mm thick of standard size round, square or triangle in shape fixed by foam tape mounting including cost of materials and fixing charges etc complete

2

2500

1250.1

... More
OD174373/2023-2024:Providing and fixing signage with vinyl sticker type sheet including printing ncecessary emblems of standard size, font and colour as specified by the Engineer in charge

2

1133

566.98

... More
OD174374/2023-2024:Providing and fixing access friendly drinking water dispenser unit with lever handle tap mounted on wall with special type stand etc including cost of unit and conveyance etc complete

100

1161500

11615

... More
OD174375/2023-2024:Providing and fixing special type chest support stainless steel grab bar for urinals in which the front bar have 100mm long for chest suppoert and side U shaped bars of length 600mm is provided for user to hold on while standing etc including cost of materials and conveyance etc complete

10

6449

644.93

... More
OD174376/2023-2024:Providing and fixing U- shaped moveable stainless steel grab bar of standrad lenght and approved make as per the direction of Engineer in charge for providing in toilets and urinals for using the persons with disabilities including cost of materials, fixing charges etc complete

2

1766

883.21

... More
OD174377/2023-2024:Providing and fixing L-shaped stationary stainless steel grab bar of standrad lenght and approved make as per the direction of Engineer in charge for providing in toilets and urinals for using the persons with disabilities including cost of materials, fixing charges etc complete

2

1785

892.84

... More
12.41.1:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter

200

48230

241.15

... More
12.42.3.1:Single tee with door75x75x75 mm

100

16772

167.72

... More
12.42.5.1:Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5075 mm bend

100

10779

107.79

... More
overhead tank(Civil work)

-

-

-

... More
OD174342/2023-2024:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum and excess cement cost is not payable. Excess/less cost of cement as per mix design is not payable or recoverable. All work above plinth level up to v level

63.48

720967

11357.39

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

9522

953628

100.15

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

288.98

254261

879.86

... More
OD174343/2023-2024: Providing and fixing water proof glossary ceramic sump/overhead wall tiles conforming to (thickness to be specified by the manufacturer), of approved make, in all colours, shades &size as approved by Engineer -in-Charge, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing , excluding pointing etc .complete

168.08

199257

1185.49

... More
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

40000

422800

10.57

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

67.87

39432

580.99

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

46.2

20688

447.81

... More
Rain water Harvesting(Civil work)

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

300

90771

302.57

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

120

13005

108.38

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

18

124974

6943.04

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

20

6832

341.62

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

246.56

180158

730.69

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

88.44

73501

831.09

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

8.4

5560

662.02

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

7164.72

717546

100.15

... More
OD38580/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Note:-cement content considered in this item is @340kg/cum and excess cement cost is not payable. All work above plinth level

59.31

673606

11357.39

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

296.59

78127

263.42

... More
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

177.68

69941

393.64

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

89.24

51847

580.99

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

88.44

39604

447.81

... More
50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

15

4260

284.06

... More
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

15

5761

384.07

... More
50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow

15

1435

95.71

... More
50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend

15

1339

89.32

... More
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow

15

1626

108.43

... More
50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow

15

1591

106.11

... More
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

15

2427

161.86

... More
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

15

2634

175.65

... More
23.5:Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

38.4

61089

1590.86

... More
23.6:Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

38.4

61089

1590.86

... More
23.7:Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

38.4

61089

1590.86

... More
DIAS(Civil work)

-

-

-

... More
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

18892.22

3655077

193.47

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1900

1311209

690.11

... More
9.156.2:Providing and fixing Pre-laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked, to backing or studding with screws etc. complete (Frames, backing or studding to be paid separately).Pre-laminated with decorative lamination on both dide exterior Grade-I MDF Board 18 mm thick confirming to IS:14587.

628

813354

1295.15

... More
9.34.3:Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.20 mm thick

795.4

3139268

3946.78

... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

1.8

281015

156119.69

... More
Ramp on both sides of entrance(Civil work)

-

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

7.41

51447

6943.04

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

13.5

4084

302.57

... More
50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

3.41

21404

6280.6

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

13.17

3468

263.42

... More
11.20.1:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement

36.6

53620

1465.03

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

200

138022

690.11

... More
Ornamental work (Civil work)

-

-

-

... More
13.3.1:20 mm cement plaster of mix:1:4 (1 cement : 4 fine sand)

1007.2

441182

438.03

... More
13.24.2:Extra for plastering done on moulding cornices or architraves including neat finish to line and level:In two coats

1007.2

1061011

1053.43

... More
Entrance Gate(Civil work)

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

17.52

5301

302.57

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

3.02

22196

7340.25

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

1.46

10164

6943.04

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

9.6

3279

341.62

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

12

7944

662.02

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

711.6

71266

100.15

... More
OD38630/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All work up to plinth level

3.56

34420

9674.21

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

36

31674

879.86

... More
5.9.21:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

25.2

19389

769.43

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

18

14959

831.09

... More
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

4.32

3972

919.53

... More
OD38631/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Note:-cement content considered in this item is @340kg/cum and excess cement cost is not payable. All work above plinth level

8.46

96083

11357.39

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1221.6

122343

100.15

... More
50.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

3.64

28113

7719.38

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

134.18

42940

320.02

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

4

1635

408.77

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2.56

697

272.62

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

134.18

9658

71.98

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

134.18

20699

154.27

... More
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

28.22

5575

197.53

... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.1

15299

156119.69

... More
9.5.1.2:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.30 mm thick shutters

1.89

7536

3987.41

... More
9.7.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

1.98

6986

3528.48

... More
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

600

116082

193.47

... More
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

4

7198

1799.51

... More
OD7949/2024-2025:Supply & Fixing stainless steel embossed letter Malayalam or English font size 60cm height (dot)(.),comma(,)etc 15cm height to the name with bolts and nuts,drilling and fixing to the panel with synthetic resin to correct line and level as per direction of Dept.officer's at site

60

141928

2365.48

... More
Car parking shed(Civil work)

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

215.28

65137

302.57

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

184.39

1280213

6943.04

... More
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

5912.51

1016952

172

... More
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

15937.16

3083362

193.47

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

256.04

2084471

8141.13

... More
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

14.4

90660

6295.87

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

208

66564

320.02

... More
OD6353/2024-2025:Providing and fixing truss less roofing with PPGI pre -painted Alu-zinc steel sheet (galvalume sheet) .8mm thick off white colour with galvalume gutter on small bay etc (size,shape and pitch of corrugation as approved by Engineer in charge). The sheet shall be fixed using self drilling/self tapping srews of size with EPDM seal,complete upto any pitch in horizontal /vertical or curved surfaces, excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required

420

1378553

3282.27

... More
OD7803/2024-2025:Providing and fixing Alu-zinc coated 0.35 mm thick Gi Trafford sheets (Jindal product) roofing including vertical/ curved surface nuts 8 mm diameter

1300

855595

658.15

... More
12.4.1:Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2

100

93706

937.06

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

1110

161771

145.74

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

208

14971

71.98

... More
14.53.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work

208

21116

101.52

... More
OD42282/2024-2025:Providing and fixing Euro guard pathy(150 mm gutter ) of approved quality in frame work with necessary screws, silicon etc complete as per direction of engineer in charge

320

128825

402.58

... More
Electrification(Electrical work)

-

-

-

... More
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

2231

2674500

1198.79

... More
1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

24

30715

1279.81

... More
OD221017/2023-2024:Supply conveyance, installation, testing and commissioning of 3000 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficiency not less than 110l/w, pf greater than 0.95, THD less than or equal to 10% directly on ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required(Cree/Osram/lumilled/Nichea or equalent make (UGR less than 19)

85

514981

6058.61

... More
OD222531/2023-2024:Supply conveyance, installation, testing and commissioning of 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficiency not less than 110l/w, pf greater than 0.95, THD less than or equal to 10% directly on ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required(Cree/Osram/lumilled/Nichea or equalent make (UGR less than 19)

4

24964

6241.01

... More
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

249

312323

1254.31

... More
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture

137

177019

1292.11

... More
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture

961

1459912

1519.16

... More
90.3.10:Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.

961

227891

237.14

... More
OD181250/2023-2024:Supply and fixing PVC Batten/Angle Holder with 9W LED bulb and aluminium shade and giving connection etc as required.

168

49192

292.81

... More
OD253771/2023-2024:Supply and fixing LED bulk head fitting having power consumption not more than 10W and light output less than 1100 Lumens with System efficacy>115 Lumen/Watt with premium quality diffuser for even distribution of light to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.

123

69795

567.44

... More
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

4

20108

5027.19

... More
OD253774/2023-2024:Supply, conveyance, installation, testing and commissioning of 10W LED mirror lamp complete with all accessories and lamps etc. and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.(K Lite 1597 or equivalent)

22

27414

1246.1

... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

800

141304

176.63

... More
OD41039/2024-2025:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

800

2577696

3222.12

... More
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

800

331248

414.06

... More
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

4000

180200

45.05

... More
90.4.6:Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.

19

2810

147.91

... More
OD254660/2023-2024:Supply of medium duty wall mounting fan having sweep 450 mm.

19

92577

4872.49

... More
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

63

30340

481.59

... More
OD253544/2023-2024:Supply, conveyance, installation, testing and commissioning of 150 mm, single phase, light duty exhaust fan in plastic body with self opening louvers in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

22

37845

1720.24

... More
OD253545/2023-2024:Supply, conveyance, installation, testing and commissioning of 200 mm, single phase, light duty exhaust fan in plastic body with self opening louvers in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

20

36614

1830.7

... More
OD253546/2023-2024:Supply, conveyance, installation, testing and commissioning of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

21

44664

2126.88

... More
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell

25

4806

192.25

... More
90.5.1.6:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Gong bell 75mm-without MS box

22

14831

674.18

... More
1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep

47

9392

199.83

... More
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

5000

881600

176.32

... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

4500

294390

65.42

... More
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm

2000

242180

121.09

... More
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm

500

98130

196.26

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

1000

90950

90.95

... More
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm

400

68856

172.14

... More
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

1000

141520

141.52

... More
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm

200

37738

188.69

... More
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm

100

26649

266.49

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

7700

778855

101.15

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1500

164250

109.5

... More
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

100

11162

111.62

... More
OD181257/2023-2024:Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required. 20 mm dia

135

7909

58.59

... More
OD181258/2023-2024:Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required. 25 mm dia

35

2250

64.3

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

1781

184084

103.36

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

52

8294

159.51

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

2311

310644

134.42

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

52

11006

211.67

... More
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator

47

26595

565.87

... More
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket

47

14899

317.01

... More
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator

47

6033

128.38

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

94

27655

294.21

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

130

42104

323.88

... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

515

238774

463.64

... More
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

15

3563

237.56

... More
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface

15

5049

336.6

... More
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

5

5137

1027.5

... More
OD203649/2023-2024:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure for independent mounting of MCB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required.

23

14832

644.87

... More
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

6

12789

2131.61

... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

4

9944

2486.2

... More
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

4

11883

2970.77

... More
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

95

271073

2853.41

... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

36

236195

6560.98

... More
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

21755

7251.73

... More
90.11.1.16:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

7942

7942.48

... More
90.11.1.20:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

9635

9635.67

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1336

322737

241.57

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

112

112054

1000.49

... More
OD254502/2023-2024:Supplying and fixing 40-63A rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

12

19452

1621.07

... More
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

224

2231

9.96

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

54

22142

410.04

... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

116

116904

1007.8

... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

21

21332

1015.83

... More
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

16

40605

2537.83

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

91

289406

3180.29

... More
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

15

50448

3363.2

... More
90.12.5.36:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 300 sq mm

80

133684

1671.05

... More
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

1000

223930

223.93

... More
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

725

275376

379.83

... More
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp

70

31548

450.69

... More
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

160

92990

581.19

... More
90.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm

70

47991

685.59

... More
90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm

260

227463

874.86

... More
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

100

124381

1243.81

... More
90.12.7.35:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm

45

68936

1531.92

... More
90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm

60

107573

1792.89

... More
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

2000

491740

245.87

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

1000

277260

277.26

... More
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

60

14381

239.69

... More
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

24

8728

363.68

... More
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

797

398.98

... More
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

8

3564

445.52

... More
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

1146

573.16

... More
9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

12

7108

592.41

... More
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

1700

850.02

... More
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

6

5879

979.98

... More
9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

8

9072

1134.02

... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

182

48297

265.37

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

50

15113

302.26

... More
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size

30

4311

143.7

... More
90.12.9.7:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench120/102.5 mm or nearest size

5

1597

319.44

... More
90.12.10.7:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation120/102.5 mm or nearest size

83

38858

468.18

... More
90.14.28.1:S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor

1

897

897.23

... More
90.14.28.13:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 2 HP submersible motor pumps (DOL)

1

1953

1953.05

... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

6

45174

7529.02

... More
OD198816/2023-2024:Supply and providing plate earthing as per IS 3043 with 1200x1200x12mm GI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25x3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450x450x450 mm) including test joint for the earthing system using 2x32x3 mm GI strip, earth lead from the test joint to the earth electrode using 32 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required and providing 450x450x10mm cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.

6

77030

12838.43

... More
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)

300

8703

29.01

... More
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)

500

22465

44.93

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

1000

63870

63.87

... More
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

570

56219

98.63

... More
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)

15

2882

192.16

... More
90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)

100

44653

446.53

... More
90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

2550

1220634

478.68

... More
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)

50

1220

24.4

... More
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)

112

2842

25.38

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

110

2998

27.26

... More
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

50

1397

27.95

... More
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

260

284206

1093.1

... More
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree

20

5042

252.13

... More
90.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree

20

7428

371.43

... More
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

20

5042

252.13

... More
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

30

4283

142.77

... More
90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover

200

22590

112.95

... More
90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer

30

1960

65.36

... More
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)

200

555070

2775.35

... More
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

18

61661

3425.62

... More
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

370

17345

46.88

... More
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

40

41578

1039.45

... More
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

1800

300690

167.05

... More
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

37525

248040

6.61

... More
90.14.7:Supply and providing copper earth bus in the panel board

12465

78280

6.28

... More
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.

8

10951

1368.94

... More
OD254357/2023-2024:Supply and installation of Voltmeter Selector Switch 6A 3 Pole.

2

398

199.44

... More
OD254358/2023-2024:Supply and installation of Analog Volmeter 0-500V with frequency 50 Hz.

2

4664

2332.1

... More
OD181266/2023-2024:Providing and fixing following 50/5 to 75/5 A, 5 VA, accuracy class 3, Resin Cast Metering CT in existing panel and giving connection complete

8

8524

1065.55

... More
OD181269/2023-2024:Providing and fixing following metering ct 100/5A 5VA /1A accuracy class 0.5 existing panel and giving connection complete

10

9375

937.59

... More
OD254791/2023-2024:Supply and installation of 200/5 A, resin cast metering CT of accuracy class 0.5.

26

24536

943.71

... More
OD254790/2023-2024:Supply and installation of 500/5 A, resin cast metering CT of accuracy class 0.5.

12

13308

1109.04

... More
OD181274/2023-2024:Supply and Fixing of Illuminated Flush head Actuator - Red with legend 'OFF', (Contact - 1 NC) and giving connection etc as required

8

2152

269.03

... More
OD181275/2023-2024:Supply and Fixing of Illuminated Flush head Actuator - Green with legend 'ON', (Contact - 1 NC) and giving connection etc as required

8

3144

393.06

... More
OD181276/2023-2024:Supply, conveyance, installation, testing and commissioning of the Panel temperature controlled fan 100x100mm size 24V DC /240V AC with thermostat and giving connection as required.

2

1486

743.21

... More
90.14.11.4:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 630A to 800A with CBCT.

1

4405

4405.79

... More
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

57

109812

1926.53

... More
90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A

2

4444

2222.13

... More
OD253753/2023-2024:Supply and providing Spreader Terminal for MCCB upto 250A.

57

122546

2149.93

... More
OD181278/2023-2024:Spreader/Terminal adapter Kit Extended terminal for 4 pole MCCB of rating upto 630 A (8 pcs) cat no. CM92004OOOO / Equivalent make

2

7616

3808.17

... More
2.1.5:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N

1

9635

9635.13

... More
2.1.7:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.320 Amp TP&N

1

17543

17543.2

... More
2.2.14:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA

17

154517

9089.28

... More
2.2.15:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 Amp, 36 KA

6

110092

18348.83

... More
2.2.16:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 Amp, 36 KA

1

20919

20919.67

... More
2.2.19:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.630 Amp, 50 KA, FPMCCB

2

78743

39371.6

... More
90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

33

153563

4653.45

... More
OD252715/2023-2024:Supply and installation of TPN Automatic Changeover with Current Limiter conforms to IEC 60947-6, IEC 60947-3, Range of Current Ratings DG side-125A, EB side-125A, RoHS compliant.

1

33684

33684.83

... More
OD252716/2023-2024:Supply and installation of the following capacity Automatic Transfer Switch inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required. 200A, 415 V, 50 Hz, AC 23 A duty, 4P Motorised with inbuilt LCD Controller.

1

51114

51114

... More
OD252717/2023-2024:Supply and installation of TPN Automatic Changeover with Current Limiter conforms to IEC 60947-6, IEC 60947-3, Range of Current Ratings DG side-63A, EB side-63A, RoHS compliant.

11

148964

13542.26

... More
90.14.24.44:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.

2

3559

1779.73

... More
90.14.24.47:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.

3

10591

3530.63

... More
90.14.24.50:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 440 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel without block reactor.

3

20568

6856.09

... More
OD253743/2023-2024:Supply and fixing Copper wound block reactor transformer, 400 V, 5 KVAr suitable for filtering harmonics up to 7% THD.

2

11278

5639.34

... More
OD253744/2023-2024:Supply and fixing Copper wound block reactor transformer, 400 V, 10 KVAr suitable for filtering harmonics up to 7% THD.

3

26556

8852.16

... More
OD253742/2023-2024:Supply and fixing Copper wound block reactor transformer, 400 V, 20 kVAr suitable for filtering harmonics up to 7% THD.

3

38303

12767.8

... More
OD253745/2023-2024:Supply installation testing and commissioning of intelligent power factor controllers-8 stage, 440/110 V, 5 A/ 1 A, Three Phase current and voltage measurement, PF display-3 digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains-DG application, Communication through inbuilt MODBUS RS-485 Protocol.

1

11763

11763.06

... More
OD253746/2023-2024:Supply and Installation of three pole capacitor duty contactors for switching capacitor banks up to 5 kVAr rating with AC coil and 1 NO contact.

2

4795

2397.67

... More
OD253747/2023-2024:Supply and Installation of three pole capacitor duty contactors for switching capacitor banks of 7.5 to 10 kVAr rating with AC coil and 1 NO contact.

3

8285

2761.86

... More
OD253741/2023-2024:Supply and Installation of three pole capacitor duty contactors for switching capacitor banks of range 12.5 to 20kVAr rating with AC coil and 1 NO contact.

3

10588

3529.64

... More
90.14.11.9:MCCB AccessoriesSupply and fixing auxiliary switch (1 NO + 1 NC) in the existing MCCB of rating up to 630 A.

1

827

827.02

... More
OD253758/2023-2024:Supply and installation of DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 with Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV safefail for 120 Min : 442 V. Health Status Indication in all catridges.Total Response time <25 nano seconds. Protec T1 (4+0) or Equivalent

4

100843

25210.88

... More
OD253759/2023-2024:Supply and installation of DIN Rail Surge Protection Device (4+0) Class B+C/ Type 1+2 with Total Impulse current-10 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV safefail for 120 Min : 442 V. Health Satus Indication in all the catridges.Total Response Time <25 nano seconds. Protec T2 (4+0) or Equivalent

10

158027

15802.73

... More
OD254439/2023-2024:Supply and fixing 32A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc.

27

9171

339.67

... More
OD254435/2023-2024:Supply and fixing 63A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc.

12

4768

397.36

... More
OD254434/2023-2024:Supply and fixing 125 A fuse holder with HRC fuse link in the existing meter board and giving connection

3

3424

1141.55

... More
OD254444/2023-2024:Supply and fixing 160A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc.

3

2046

682.32

... More
OD254440/2023-2024:Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc.

9

2065

229.54

... More
OD254436/2023-2024:Supply and fixing 63A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc.

4

1247

311.82

... More
OD254433/2023-2024:Supply and fixing 125 A, 415 V , 2 way neutral link mounted on DMC/ SMC base in the existing meter board

1

350

350.51

... More
OD254443/2023-2024:Supply and fixing 160A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc.

1

434

434.27

... More
OD254501/2023-2024:Supplying and fixing 2A rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

72

26097

362.47

... More
OD253760/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.50 sq mm single run with required sockets.

300

8436

28.12

... More
OD253761/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 2.50 sq mm single run with required sockets.

30

1103

36.77

... More
OD253762/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4.00 sq mm single run with required sockets.

200

10128

50.64

... More
OD253763/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 6.00 sq mm single run with required sockets.

100

6797

67.97

... More
OD253764/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10.00 sq mm single run with required sockets.

80

8903

111.29

... More
OD253765/2023-2024:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 16.00 sq mm single run with required sockets.

50

8336

166.73

... More
OD253767/2023-2024:Supply and installation of three phase multi function meters to read V, A and F-Accuracy class 1

10

54932

5493.24

... More
OD253768/2023-2024:Supply and installation of LED indicators for all voltage ranges-Red, Green, Yellow or Orange colour.

24

2051

85.49

... More
OD253769/2023-2024:Supply and installation of LED indicators for all voltage ranges-Blue colour.

12

1366

113.9

... More
OD253770/2023-2024:Aluminium anodised legend plate of size 100 x 40 mm. with inscription of BUS BAR CHAMBER, EART and CABLE ALLEY.

50

2054

41.08

... More
OD254799/2023-2024:Providing and fixing Danger notice board 250x200mm enamelled in existing panel and giving connection complete

10

1968

196.83

... More
OD247338/2023-2024:Supply and providing 3mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength.

20

59059

2952.96

... More
OD247339/2023-2024:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.

12

3066

255.53

... More
OD247340/2023-2024:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

2

580

290.38

... More
OD181289/2023-2024:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. as per IS 2546

2

649

324.73

... More
OD181294/2023-2024:Supply of Electrical safety hand Glows 2.9mm minimum thickness,withstanding 26 KV protection made by Natural Latex, off white colour ( Certification shall be attached) .

2

5575

2787.6

... More
OD247342/2023-2024:Painting letters or figures of the follwing sizes with enamel paint as identfication mark to SB, DB, panel board etc as required. 2.5 cm, 4 cm, 5 cm height.

1000

12060

12.06

... More
4.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

240

180556

752.32

... More
4.1.6:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness

335

283858

847.34

... More
4.1.7:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

400

370392

925.98

... More
90.15.3.1:Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters

12

224204

18683.7

... More
90.15.3.7:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters

6

164981

27496.87

... More
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

12

55502

4625.22

... More
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

12

90181

7515.12

... More
OD253756/2023-2024:Supply & installation of dust and vermin proof, wall mounting, Sintex box of size 200x140x95mm hinged door construction for the front side with knock out for cable entry and exit.(GSJB-2014).

18

11979

665.51

... More
OD181292/2023-2024:Charges towards the preparation of necessary plan, scheme and other related papers for additional sheet

128

2229

17.42

... More
OD181293/2023-2024:Charges towards the preparation of necessary plan, scheme and other related papers for submission to KSELB /KSEB.

32

24840

776.25

... More
SITC of Transformer(Electrical work)

-

-

-

... More
OD223637/2023-2024:Supply, Fabrication, Installation, testing and commissioning of dust and vermin proof sheet steel constructed using 2 mm CRCA sheet and powder coated Cubicle type 12 kV, SF6 Ring Main Unit complete (Extensible/Outdoor)(2 Isolator+1 Breaker)FBX-E /12-20/CCT2 /Outdoor-Motorised+Battery Charger.

1

676545

676545

... More
OD181218/2023-2024:Supply,installation ,testing and commissioning of 315KVA USS , 11kv/433v,50hz,3phase,AN cooled,delta/star,with copper windings with tappings +5 to -5 in steps of 2.5%, class f insulation, Indoor type ,laser scribed core ,confirming to ECBC norms ,electrolytic copper interconnections with heat shrink sleeves tinned at the point of contacts , 11KV,630A, VCB ,26.3KA for 3 sec, horizontal drawout fitted with manual spring charged etc complete with necessary multifunction meter( to read VA ,PF,KW ,KWh ,KVA,KVAr ,KVARh ,THD ,Phase angle -3ph accuracy class-1 LCD) ,11KV CT & PT ,master trip relay,push button ,provision for TOD meter (TOD meter and CTs, PTs unit compartment shall be so fabricated as to enable the KSEB authorities to seal it),annunciation panel with alarm,strip heater,thermostat etc complete enclosed in CRCA powder coated sheet conforming to IP 23 of minimum thickness 2mm.The LT portion shall be provided with 1No 4Pole 630A 50kA thermal magnetic type MCCB . All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The USS shall be installed as per the directions of the department officers at site.

1

1273923

1273923.02

... More
OD181220/2023-2024:Supply of PVC insulated and PVC sheathed XLPE armoured aluminium power cable, 11 KV grade of the following sizes , making good the damages , colour washing etc. as required.3 core 300 sq mm

100

209562

2095.62

... More
8.1.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

85

49599

583.52

... More
8.4.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

15

1741

116.11

... More
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

3

42444

14148.23

... More
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

20792

20792.45

... More
OD41023/2024-2025:Supply and fixing three Phase HT Trivector Meter 3Phase 4 Wire /5A with an accuracy of Class 0.2S DLMSC compatable as per the KSEB Standard.

1

38548

38548.6

... More
SITC of DG(Electrical work)

-

-

-

... More
OD181303/2023-2024:Supply ,Conveyance Installation ,Testing and Commissioning of 320 KVA DG set with standard control panel ,compliance with CPCB IV + norms as per the technical details given below. Engine. a. Make of Engine - As specified in accepted list of material. b. Type of Engine-Diesel Engine.c.No. of cylinder- Suitable to develop the required BHP as per manufacturer's standards. d.Method of cooling - Water cooling(with radiator) e. Aspiration - Turbo charged after cooled. f. Design - Suitable for generator set application. g. Out put - BHP at 1500 RPM under NTP conditions or other BHP ratings Specified by the respective manufactures capable of delivering the required power for alternator. Standard accessories with diesel engine. a. Fly wheel housing and flywheel to suit single bearing alternator (Close coupled arrangement).b. Air cleaner, c. Coolent kit.d, Fuel Pump, e Electronic governor backed with mechanical governor. f. Fuel filter. g .Lubricating oil filter, h. Residential type exhaust silencer. Engine Instrument Panel. a. starting switch with key or button .b. Lubricating oil temperature gauge. c.Lubricating oil pressure gauge, d. Water temperature gauge. e.RPM Indicator with hour meter. f. Battery charging ammeter. Safety Controls for Engine-a.Trip for low lubricating oil pressure. b.Trip for high water temperature. c.Providing necessary warning system and other safeties as contemplated in relevant ISS. d.Fuel shut off facility at over speed. Fuel pipe.Oil resistant flexible hoses & 25mm dia or nearest size MS pipe as per manufactures requirement for fuel line. Alternator-a.make-As specified in accepted make of material .b .Type - Self excited and self regulated. capacity - 320 KVA KW at 0.8 PF. d. System of voltage - 3 phase, 415V. e.Speed - 1500 RPM. f. Voltage regulation band - 2.50% of rated Voltage .g. Insulation - Class F/H. h. AVR - AVR shall be provided with a motorized or solid state potentiometer. i.IP rating of enclosure - IP 23.j. Wave form distortion - No load<1.5%, non-distorting balanced linear load<5%.k.Telephone interference factor - Better than 50 l. Total harmonic factor - Better than 2%. Standard control panel with suitably rated MCCB with overload and E/F release and standby low set earth fault relay using neutral CT .The alternator should confirm to IS 4722. Routine tests as per relevant ISS shall be conducted and test reports of the same shall be furnished at the time of delivery. Fuel tank-Integral type fuel tank of adequate capacity with full tank diesel. Battery-Required number of suitably rated fully charged battery with leads and terminals as required as per manufactures requirements. Battery Charger:Supply and providing 24V battery charger suitable for charging battery of DG Set (180 Ah) consisting of the following. a. Transformer / Rectifier with surge protection device. b. Charging facility for 12V & 24 V battery. c. DC Volt Meter. d. DC Ammeter to indicate both charging and discharging current.e. Selector Switch for trickle and boost charging. f. Automatic overcharge cut off facility .Acoustic enclosure: a,The DG set shall be supplied along with specially designed company fabricated (to be fabricated in the same company firm where the DG set delivered) acoustic enclosure to meet the stringent MOEF/ CPCB norms of 75 dBA@ 1m at 75% load under free field conditions. b.Sufficient space and clearance shall be maintained inside the enclosure to have optimum serviceability.c.Air inlet louvers shall be designed in such a way as to operate the set at rated load even at 50ºC enclosure temperature. d. The enclosure shall be with UV resistant powder coating capable to withstand extreme environments. e. Hardware used shall be of only stainless steel make, f.Insulation material shall confirm to IS 8183 specification. Documents to be supplied:a.Engine manual, b.Spare parts book, c.Warranty certificate, d.Alternator manual & test certificate, e.1 set control wiring drawing. Installation:It shall be installed in the pre-constructed concrete bed complying to relevant IS standards,IE rules and as per the direction of the official. Testing and commissioning:The DG set shall be tested as per relevant IS standards. Block load testing shall also be conducted and DG should have block load capacity of 55%.The load required for testing shall be made available at site by the selected agency at their own expense. During defect liability period ,periodical checkup & services as per manufacturers recommentation and repair shall be arranged and any spare/component which require replacement /repair shall be done immediately at free of cost.

1

4488086

4488086.07

... More
OD181305/2023-2024:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

1

184

184

... More
OD181306/2023-2024:Supply and providing following size B class GI pipe with specials and flanged coupling in each full length of pipe, as additional exhaust piping, fixing the same firmly to the building/structure using necessary supports, such angle iron, MS clamp etc. Painting the pipe and accessories with synthetic enamel paint over a coat of zychromate primer etc as required 100 mm dia

9

12107

1345.28

... More
SITC of UPS(Electrical work)

-

-

-

... More
OD231755/2023-2024:Supply,installation,testing and commissioning of 2kVA online UPS with following specifications.A) BIS Certified 2kVA online UPS. B) Pure sine wave. C) Capacity-2kVA With Isolation Transformer. D) Back up time: 120 minutes. E) Single Phase Input Single Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: unity. H) THD-<=10%, I) Input voltage range : 140V -280V with cut off, J) Nominal output voltage=230 V AC Single phase, K) Output voltage regulation- +/-1%, L) efficiency - >87%. M) Ambient Temperature : 0-40°C. N) Generator Compatibility, O) Battery over charge & under charge cut off. P) Battery: CPRI Certified Tall Tubular Battery with battery stand. Q) By pass arrangement. R) Mandatory Certification-1) EN/IEC 620401 for General Safety compatibility, 2) EN/IEC 620402 for Electromagnetic Compatibility, 3) EN/IEC 620403 for Performance, 4) EN/IEC 620404 for Environmental Compatibility

1

194869

194869.36

... More
OD231754/2023-2024:Supply,installation,testing and commissioning of 2kVA online UPS with following specifications.A) BIS Certified 2kVA online UPS. B) Pure sine wave. C) Capacity-2kVA With Isolation Transformer. D) Back up time: 30 minutes. E) Single Phase Input Single Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: unity. H) THD-<=10%, I) Input voltage range : 140V -280V with cut off, J) Nominal output voltage=230 V AC Single phase, K) Output voltage regulation- +/-1%, L) efficiency - >87%. M) Ambient Temperature : 0-40°C. N) Generator Compatibility, O) Battery over charge & under charge cut off. P) Battery: CPRI Certified Tall Tubular Battery with battery stand. Q) By pass arrangement.R) Mandatory Certification-1) EN/IEC 620401 for General Safety compatibility, 2) EN/IEC 620402 for Electromagnetic Compatibility, 3) EN/IEC 620403 for Performance, 4) EN/IEC 620404 for Environmental Compatibility

3

408790

136263.55

... More
OD231753/2023-2024:Supply,installation,testing and commissioning of 5kVA online UPS with following specifications. A) BIS Certified 5kVA online UPS, B) Pure sine wave. C) Capacity-5kVA With Isolation Transformer. D) Back up time: 30 minutes. E) Single Phase Input Single Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: unity. H) THD-<=10%, I) Input voltage range : 140V -280V with cut off. J) Nominal output voltage=230 V AC Single phase, K) Output voltage regulation- +/-1%, L) efficiency - >87%, M) Ambient Temperature : 0-40°C, N) Generator Compatibility, O) Battery over charge & under charge cut off. P) Battery: CPRI Certified Tall Tubular Battery with battery stand. Q) By pass arrangement. R) Mandatory Certification-1) EN/IEC 620401 for General Safety compatibility, 2) EN/IEC 620402 for Electromagnetic Compatibility, 3) EN/IEC 620403 for Performance, 4) EN/IEC 620404 for Environmental Compatibility

1

207833

207833.69

... More
OD230063/2023-2024:Supply,installation,testing and commissioning of 6kVA online UPS with following specifications. A) BIS Certified 6kVA online UPS, B) Pure sine wave C) Capacity-6kVA With Isolation Transformer. D) Backup time: 30 minutes. E) Single Phase Input Single Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: unity. H) THD-<=10%, I) Input voltage range: 140V -280V with cut off, J) Nominal output voltage=230 V AC Single phase, K) Output voltage regulation- +/-1%, L) efficiency - >87%, M) Ambient Temperature : 0-40°C, N) Generator Compatibility, O) Battery over charge & under charge cut off. P) Battery: CPRI Certified Tall Tubular Battery with battery stand. Q) By pass arrangement. R) Mandatory Certification-1) EN/IEC 620401 for General Safety compatibility, 2) EN/IEC 620402 for Electromagnetic Compatibility, 3) EN/IEC 620403 for Performance, 4) EN/IEC 620404 for Environmental Compatibility

3

733046

244348.69

... More
OD230064/2023-2024:Supply,installation,testing and commissioning of 10kVA online UPS with following specifications. A) BIS Certified 10kVA online UPS, B) Pure sine wave, C) Capacity-10kVA With Isolation Transformer. D) Back up time: 30 minutes. E) Three Phase Input Single Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: 0.95. H) THD-<=5%, I) Input voltage range : 180V -480V with cut off, J) Efficiency - >94%, K) Ambient Temperature : 0-40°C, L) Generator Compatibility, M) Battery over charge & under charge cut off. N) Battery: CPRI Certified Tall Tubular Battery with battery stand. O) By pass arrangement. P) Mandatory Certification-1) EN/IEC 620401 for General Safety compatibility 2) EN/IEC 620402 for Electromagnetic Compatibility. 3) EN/IEC 620403 for Performance 4) EN/IEC 620404 for Environmental Compatibility.

2

1041858

520929.08

... More
OD253315/2023-2024:Supply,installation,testing and commissioning of 20kVA online UPS with following specifictions. A) BIS Certified 20kVA online UPS. B) Pure sine wave. C) Capacity-20kVA With Isolation Transformer. D) Back up time: 30 minutes. E) Three Phase Input Single Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: 0.95. H) THD-<=5%, I) Input voltage range : 180V -480V with cut off, J) Efficiency - >94%, K) Ambient Temperature : 0-40°C. L) Generator Compatibility. M) Battery over charge & under charge cut off. N) Battery: CPRI Certified Tall Tubular Battery with battery stand. O) By pass arrangement. P) Mandatory Certification-1) EN/IEC 620401 for General Safety compatibility 2) EN/IEC 620402 for Electromagnetic Compatibility. 3) EN/IEC 620403 for Performance 4) EN/IEC 620404 for Environmental Compatibility.

1

885641

885641.04

... More
OD223558/2023-2024:Supply,installation,testing and commissioning of 30kVA online UPS with following specifications. A) BIS Certified 30kVA online UPS, B) Pure sine wave. C) Capacity-30kVA With Isolation Transformer. D) Back up time: 30 minutes. E) Three Phase Input Three Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: unity. H) THD-<=3%, I) Input voltage range : 305V -485V with cut off, J) Efficiency - >94%, K) Ambient Temperature : 0-40°C, L) Generator Compatibility, M) Battery over charge & under charge cut off. N) Battery: CPRI Certified Tall Tubular Battery with battery stand. O) By pass arrangement. P) Indications : Digital indications of Input V & A, output V & A, Battery charge, Temperature. R) Mandatory Certification: 1) EN/IEC 620401 for General Safety compatibility 2) EN/IEC 620402 for Electromagnetic Compatibility. 3) EN/IEC 620403 for Performance 4) EN/IEC 620404 for Environmental Compatibility

1

1040152

1040152.66

... More
OD223559/2023-2024:Supply,installation,testing and commissioning of 40kVA online UPS with following specifications. A) BIS Certified 40kVA online UPS, B) Pure sine wave. C) Capacity-40kVA With Isolation Transformer. D) Back up time: 30 minutes. E) Three Phase Input Three Phase output and Earth, F) Input power factor=0 .99 @ full load, G) Output power factor: unity. H) THD-<=3%, I) Input voltage range : 305V -485V with cut off, J) Efficiency - >94%, K) Ambient Temperature : 0-40°C, L) Generator Compatibility, M) Battery over charge & under charge cut off. N) Battery: CPRI Certified Tall Tubular Battery with battery stand. O) By pass arrangement. P) Indications : Digital indications of Input V & A, output V & A, Battery charge, Temperature. R) Mandatory Certification: 1) EN/IEC 620401 for General Safety compatibility 2) EN/IEC 620402 for Electromagnetic Compatibility. 3) EN/IEC 620403 for Performance 4) EN/IEC 620404 for Environmental Compatibility

1

1332220

1332220.08

... More
Fire Fighting System(Electrical work)

-

-

-

... More
90.17.1.5:Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 70 m Head

1

325095

325095.39

... More
90.17.3.2:Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) a. Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head

1

91352

91352.54

... More
90.17.2.5:Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head

1

538160

538160.95

... More
90.17.5.1:Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

215458

215458.25

... More
90.17.7.1:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia

1930

972546

503.91

... More
90.17.7.2:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :32 mm dia

480

266788

555.81

... More
90.17.7.3:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm dia

10

6882

688.25

... More
90.17.7.4:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia

395

318946

807.46

... More
90.17.7.5:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia

10

10240

1024.06

... More
90.17.7.6:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia

80

90228

1127.85

... More
90.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia

1245

1831469

1471.06

... More
90.17.7.8:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia

600

1195434

1992.39

... More
90.17.15.3:Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia

2

19450

9725.23

... More
OD181313/2023-2024:Supply,installation,testing,commissioning of Expansion bellows with required flanges ,nuts,bolts & accessories 80 mm dia

1

11012

11012.58

... More
OD181314/2023-2024:Supply,installation,testing,commissioning of Expansion bellows with required flanges ,nuts,bolts & accessories.100mm Dia

2

37943

18971.69

... More
OD181315/2023-2024:Supply,installation,testing,commissioning of Expansion bellows with required flanges ,nuts,bolts & accessories.150 mm dia

2

59125

29562.92

... More
90.17.11.2:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required50mm dia

4

13651

3412.98

... More
90.17.11.3:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required65 mm dia

2

7801

3900.8

... More
90.17.11.4:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia

4

17949

4487.27

... More
90.17.11.5:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia

24

144642

6026.77

... More
90.17.11.6:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia

4

32314

8078.66

... More
90.17.14.4:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia

2

13746

6873.4

... More
90.17.14.5:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia

3

29612

9870.83

... More
90.17.23.2:Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.150mm dia

8

64313

8039.22

... More
90.17.9.2:Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel

16

88188

5511.8

... More
90.17.10.2:Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as requiredSingle headed Stainless steel

6

33070

5511.8

... More
OD181316/2023-2024:Supply,installation,testing and commissioning of Fire Hose Box for Double Hose 2mm thickness MS powder coated having locking arrangement & glass vision panel with Double Door size 750x600x250 .The cabinet shall be painted to scarlet red colour paint

22

89435

4065.25

... More
90.17.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b. 20 mm nominal internal dia gun metal globe valve & nozzle. c. Drum and brackets for fixing the equipmets on wall. d. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

22

172245

7829.33

... More
90.17.16.2:Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)

44

172106

3911.51

... More
90.17.18.1:Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal

22

46854

2129.77

... More
90.17.20:Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

16196

16196.71

... More
OD181318/2023-2024:Supplying, fixing, testing and commissioning of 0-15 Kg/sq cm100mm dia Dial type pressure gauge with isolation cock and pipe at hydrant station as per specification.

4

6046

1511.57

... More
90.17.22:Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required

5

6938

1387.65

... More
OD181319/2023-2024:Supply, installation, testing and commissioning of Gun metal Air Release valve 20mm dia

4

5814

1453.65

... More
90.17.19.3:Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :3 way - 150 mm dia M.S. Pipe

1

8419

8419.04

... More
90.17.21.1:Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler

1150

563281

489.81

... More
OD181320/2023-2024:Supply and installation of CO2 type portable fire extinguisher 4.5 kg capacity with initial charging, 1 meter hose with horn including installation brackets conforming to IS 15683 as required

21

194270

9250.98

... More
OD181321/2023-2024:Supply and providing 6Kg ABC Fire Extinguisher cap filled with mono ammonium phosphate powder 50% confirms to IS 1409, stored pressure type, with pressure gauge, the discharge time 24 sec, controllable discharge mechanism, jet range 5 meters, average discharge is 90%, appliccable on A,B & C and electrically started fire, A rating-3A, B rating 21B, construction: deep drawn & co2 mig welded, EPDM rubber hose with both end aluminium clamped, internal coating-epoxy powder coating, external coating-pure polyster powder coating(UV resistant),brass forged valves with safety pin is of ss material, sheet metal thickness ISI approved.

31

98181

3167.14

... More
OD39848/2024-2025:Supply installation testing & commissioning of 2 Kg Clean agent fire Extinguisher Modular type of following sizes suitable for below ceiling built in 1 piece with body and bottom. Mild steel body with pressure gauge refillable device and safety release device, Brass valve suitable for B and C classes of fire complete with charge of HFC 236FA/FE36(it is a blend of Hydro Fluoro carbon and organic detossificant essence P 26). The extinguisher shall have pressure gauge for indicationg inside pressure with heat sensitive glass bulb 68 degree with brass forged nozzle and sheet thickness shall not less than 2mm

2

22541

11270.64

... More
OD246250/2023-2024:Supply Installation Testing and Commissioning of 5 kg Clean agent fire Extinguisher Modular type of following sizes suitable for below ceiling built in 1 piece with body and bottom. Mild steel body with pressure gauge refillable device and safety release device, Brass valve suitable for B and C classes of fire complete with charge of HFC 236FA/FE36(it is a blend of Hydro Fluoro carbon and organic detossificant essence P 26). The extinguisher shall have pressure gauge for indicationg inside pressure with heat sensitive glass bulb 68 degree with brass forged nozzle and sheet thickness shall not less than 2mm.

8

151698

18962.33

... More
17.1.1:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

10

12812

1281.28

... More
17.1.2:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.

820

1132887

1381.57

... More
17.1.8:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning talk back slave station in surface/ recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/ microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.

16

17291

1080.71

... More
17.2.1.1:Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system ( which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications. INTELLIGENT FIRE ALARM SYSTEMTen Loop Panel

1

550980

550980.78

... More
17.2.10:Supplying, installation, testing & commissioning of addressable fire control module complete as required.

16

57950

3621.93

... More
17.2.14:Supplying, installation, testing & commissioning of addressable manual call point complete as required.

16

74779

4673.69

... More
OD181323/2023-2024:Supply & installation of Intelligent Analog Addressable Hooter required Duly Approved by EN/UL Listed

16

153635

9602.21

... More
17.3.6:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.

1

117206

117206.13

... More
17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

4700

817142

173.86

... More
17.5.3.1:Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sq mm

600

36840

61.4

... More
17.5.3.2:Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Two pair, 2-core, 1.5 sqmm

400

41336

103.34

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1000

101150

101.15

... More
17.3.3:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

32

68983

2155.73

... More
OD246253/2023-2024:Supplying and installing in position LED "EXIT" sign boards of size (180 x 300 mm) with battery backup.

32

112643

3520.1

... More
OD246254/2023-2024:Supplying and installation of autoglow "Fire Duct", "Exit", "Electrical Duct", "Fire Pump Room" sign boards of size (180 x 300 mm).

100

70019

700.19

... More
OD246255/2023-2024:Supply & installing in position laminated sheet of " FIRE EVACUATION PLAN " of suitable size fixed on wall & necessarry accessories to fix the plan on wall.

20

18248

912.41

... More
SITC of Lift(Electrical work)

-

-

-

... More
OD181299/2023-2024:Supply, Installation,Testing and Commissioning of 26 passenger gearless machine room lift with the following specification including all required standard features.1 .Type of Lift:26 Passenger capacity , Gearless 2. Load / Persons :1768 Kg. / 26persons 3 .Rated speed :1 M/Sec. 4. Travel : 12.6 Mtr ( Approx) 5. No. of floor and entrance served: 4 stops and 4 openings 6. No. of floor served :Four floors 7. Method of control : Micro processor based V3F with ARD system. 8. Size of lift well :3300 mm X 3000 mm 9. Car entrance: As per IS. 10.Leveling accuracy : As per IS 11. Car door opening : As per IS 12. Drive : Variable voltage variable frequency(V3F) 13 .Operation : Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel(SS304,make:Tata/Jindal) finish cabinet with Scratch proof Stainless steel door(sheet minimum1mm thickness), Stainless steel mirror finish ceiling, Aluminium 3mm minimum thickness anti skid flooring, fan with timer cut-off, push to talk, LED display, LED light, hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance : Automatic centre/Telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and half framed glass door . 16. Call and position indicators : Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply : 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infra red door opening system: To be provide for entire length of the door 19. Automatic Rescue Device :Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four rescue operation at full load . The rescue operation should act within 10 seconds of power failure 20. Regulation :350V- 450V (SMPS based) 21. Indication in the car : a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) push button switch for fan and light f) Non stop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel :Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests :At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit. Supply, Installation,Testing and Commissioning of 8passenger capacity machine room less gearless lift expandable to 6 floors in future with the following specification including all required standard features.1 .Type of Lift:8 Passenger capacity , Gearless 2. Load / Persons :544 Kg. / 8persons 3 .Rated speed :1 M/Sec. 4. Travel : 10.8 Mtr ( Approx) 5. No. of floor and entrance served: 4 stops and openings 6. No. of floor served :four floors 7. Method of control : Micro processor based V3F with ARD system. 8. Size of lift well :1900 mm X 1900 mm 9. Car entrance: As per IS. 10.Leveling accuracy : As per IS 11. Car door opening : As per IS 12. Drive : Variable voltage variable frequency(V3F) capable of serving 6floors13 .Operation : Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel(SS304,make:Tata/Jindal) finish cabinet with Scratch proof Stainless steel door(sheet 1mm thickness), Stainless steel mirror finish ceiling, Aluminium 3mm minimum thickness anti skid flooring, fan with timer cut-off, push to talk, LED display, LED light, hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance : Automatic centre/Telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and half framed fire rated glass door for minimum 2 Hrs. 16. Call and position indicators : Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply : 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infra red door opening system: To be provide for entire length of the door 19. Automatic Rescue Device :Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four rescue operation at full load . The rescue operation should act within 10 seconds of power failure 20. Regulation :350V- 450V (SMPS based) 21. Indication in the car : a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Non stop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel :Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests :At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit.

6

20722856

3453809.36

... More
Lightning Protection(Electrical work)

-

-

-

... More
OD231147/2023-2024:Supply and providing 2 meter air terminal with accessories:Air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm dia aluminium rod : Meets the requirement of VDE0185/305(IEC 62305) : semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Includes clamp made of SS tested to lightning current tested with VDE 0185-305 (IEC 62305) H/100KA , made of single piece sheet without welds. With stone base for high level of stability. Providing and fixing of fully solid 2m Vertical Air terminal made up of Semi-hard (E-AlMgSiO5), 16mm rod tapered to 10mm. VAT 2 or Equivalent

4

8702

2175.71

... More
OD231148/2023-2024:Supply and providing 3 meter air terminal with accessories:Air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm dia aluminium rod : Meets the requirement of VDE0185/305(IEC 62305) : semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Includes clamp made of SS tested to lightning current tested with VDE 0185-305 (IEC 62305) H/100KA , made of single piece sheet without welds. With stone base for high level of stability.

7

54359

7765.71

... More
OD231149/2023-2024:Supply and providing 4 meter air terminal with accessories:Air terminals as per IEC -62305 part-3 16mm rod tapered to 10 mm dia aluminium rod : Meets the requirement of VDE0185/305(IEC 62305) : semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Includes clamp made of SS tested to lightning current tested with VDE 0185-305 (IEC 62305) H/100KA , made of single piece sheet without welds. With multiple stone base for high level of stability.

14

123273

8805.25

... More
OD231154/2023-2024:Supply and fixing 8mm solid aluminium round conductor with suitable Stainless steel conductor holder for concrete building meets the requirement of VDE0185/305(IEC 62305) conductor to be (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. With Metallic holder for parapet and heavy approx 1kg polyamide base for non drill area: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Conductor holder @ 1 meter distance. All cross and stright joints at terrace part to be hot dip galvanized and tested in accordance with IEC 62561 including H/100kA , loosening torque test , electrical resistance and static mechanical test etc. Expansion piece to be provided wherever necessary. Should be tested as per IEC 62561 including Electrical resistance, resistivity, Tensile , cyclic test from International/National accredited lab Horizontal run-Parapet application Drillable Areas

485

178935

368.94

... More
OD231155/2023-2024:Supply and fixing 8mm solid aluminium round conductor Should be tested as per IEC 62561 including Electrical resistance, resistivity, Tensile , cyclic test from International/National accredited lab with suitable Stainless steel conductor holder: For down conductor/vertical run on wall/ concrete building Meets the requirement of VDE0185/305(IEC 62305) conductor to be (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Conductor Holder to be Stainless steel Metallic holder including M8 Screw to connect the conductor holder. Conductor holder @ 1 meter distance. Vertical Run Drillable Areas

720

284068

394.54

... More
OD231156/2023-2024:Supply and fixing 8mm solid aluminium round conductor with suitable SS conductor holder ,conductor holder should be tested as per IEC 62561 including lateral load test in International/National accredited lab for connecting 8mm solid aluminium round conductor: For concrete building Terrace application: Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. With double conductor holder. Filling weight 1Kg (frost-resistant concrete). Sleeve made of polyethylene, black, bottom polypropylene, black. Base made of polyamide PA 6, black, UV-stabilised and weather-resistant. Base can be used on almost all roofing felt systems (bitumen, PVC). Conductor holder @ 1 meter distance. Horizontal run- concrete terrace application Non-Drillable Areas

200

105150

525.75

... More
OD231161/2023-2024:Supply and fixing expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. Made of round conductor Rd 8-Alu. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip steel. Connection component should be tested for minimum Lightning current carrying capacity - H/100 kA . Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305).

14

9253

660.95

... More
OD231163/2023-2024:Providing and fixing of Test Joint , Bi metallic type with intermediate plate , made of SS 316. It should be tested for minimum Lightning current carrying capacity - N/100 kA. Suitable to connect 8mm round conductor and 10mm CU bonded conductor. Tested to IEC 62561 requirement All connection component sample to be submitted prior for approval . Test joint to be enclosed in enclosure Internal dimensions of minimum: 176x135x67 mm.

35

70137

2003.94

... More
OD231164/2023-2024:Providing and fixing of Outdoor Glass Fibre Reinforced Polycarbonate Enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm. Abox I 40 or Equivalent

35

33000

942.87

... More
OD231165/2023-2024:Supply and installation of DIN Rail Surge Protection Device (4+0) Class B&C/ Type 1&2 with Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV safefail for 120 Min : 442 V. Health Status Indication in all catridges.Total Response time <25 nano seconds. Protec T1 (4+0) or Equivalent

1

25210

25210.88

... More
OD231166/2023-2024:Supply and installation of DIN Rail Surge Protection Device (4+0) Class B+C/ Type 1+2 with Total Impulse current-10 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV .The Surge Protection Devices should have TOV safefail for 120 Min : 442 V. Health Satus Indication in all the catridges.Total Response Time <25 nano seconds. Protec T2 (4+0) or Equivalent

1

15802

15802.73

... More
OD231167/2023-2024:Supply and laying 10mm Copper bonded round conductor from earth electrode directly in ground for ring/direct test joint connection. Copper bonding to be minimum 100 micron coating. Should be tested to IEC 62561 requirements. Should be tested for Electrical resistance after salt mist cyclic test etc from International/National accredited lab , Connection component/Connectors to be SS and should be tested for minimum Lightning current carrying capacity - N/50 kA

465

551875

1186.83

... More
OD231171/2023-2024:Maintenance free Earthing system comprises of molecularly bonded copper of 99.9% tested purity , on low carbon steel of 3m length , having a diameter of 14.2 mm with copper coating thickness of 250 microns with fault current withstand capability of minimum 13 KA rms value for 1 second and I peak of 31 KA. Universal Clamp made of SS 304 for clamping, Clamp should have loosening torque tested report according to IEC 62561. Earth enhancing compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances (TCLP tested) The mineral compound shall be added 25 kg/pit. Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be minimum 250mmx 250mmx 250mm with a weight bearing capacity of 50KN.

2

25387

12693.67

... More
Installation of On-Grid Solar Plant(Electrical work)

-

-

-

... More
OD213175/2023-2024:Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box &amp; Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections &amp; Interconnections by supplying &amp; fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying &amp; fixing of necessary channel/conduit lugs and other accessories etc. as required.

24

1685710

70237.95

... More
Installation of AC(Electrical work)

-

-

-

... More
OD223643/2023-2024:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control & stabilizer etc 2.0 TR, with minimum ISEER of 5, single phase split type AC unit with comprehensive maintenance contract up to the end of defect liability period from date of commissioning including periodical services, gas topping etc. complete.(Including stand)

47

3519082

74874.09

... More
OD223648/2023-2024:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control & stabilizer etc 3.0 TR, with minimum ISEER of 5, three phase split type AC unit with comprehensive maintenance contract up to the end of defect liability period from date of commissioning including periodical services, gas topping etc. complete.(Including stand)

2

169680

84840.39

... More
OD39952/2024-2025:Supply,installation,testing and commissioning of insulated condensate drain piping out of PVC-6kg/cm2 pipes complete with hangers/ supports/ clamps/clips and all fittings etc and insulated with 13 mm thoick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-25 mm dia

200

44878

224.39

... More
OD39953/2024-2025:Supply,installation,testing and commissioning of insulated condensate drain piping out of PVC-6kg/cm2 pipes complete with hangers/ supports/ clamps/clips and all fittings etc and insulated with 13 mm thoick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-32 mm dia

10

2555

255.52

... More
OD39958/2024-2025:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge

240

161769

674.04

... More
OD39961/2024-2025:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge

10

6982

698.2

... More
OD39963/2024-2025:Supply and drawing the following sizes of multi-core PVC insulated &FRLS PVC shielded communication cabling between VRV/VRF indoor and outdoor units 650/1100v grade copper conductor flexible cables in the existing surface/recess conduit as required including giving necessary connections of the following sizes3 core 1.50 sq mm

250

27482

109.93

... More
PART -1- CCTV(Electronics Work)

-

-

-

... More
OD213749/2023-2024:Supply and Providing of 19 inch, 42U Floor standing Industrial Grade Powder coated network rack with three sliding tray ,front glass door and min 4 cooling fan with PDU 6/16A,12 socket single pole 32A MCB 6 sq mm 3m length including mounting kit , cable manager, Double side open with lock, Rolling wheels locks, Depth 1200mm width 800mm . Approved make: Netrack, President, Valrack, Vertiv.

1

81111

81111.24

... More
OD216640/2023-2024:Supply and Installation of 24 Port 10G network Stackable Managed Switch having 12x10GBASE-T and 12xSFP+,web manageable supporting ipv6, 480 Gps Switching Fabric, Switching Capacity greater than equal to 20Gbps, 512 MB RAM, AC 120/230V,Power Consumption (Max) : 97 Watts, Console: RJ45 RS232,Mini-USB. Approved Make : Cisco ,Netgear, HP, Allied Telesis, Brocade

1

243915

243915

... More
OD217185/2023-2024:Supply, Installation, testing and Commissioning of 3 meter CAT 6 Patch cord. With LSZH Compliance, Approved Make: R and M, Molex, Panduit, Beldon, Actassi, Belden.

3

728

242.75

... More
OD216069/2023-2024:Supply and installation of Network Video Recorder, support 128 Channel, Should support Resolution:- ≥ 4 MP ,Network Bandwidth 512 Mbps or better, 512 Mbps for storage , support H.265, H.264 SVC, H.264 AVC, MPEG4, MJPEG encoding format streaming access and H.264: 1920x1080 @ 540 fps, H.265: 1920x1080 @ 270 fps decoding output, Video standard 30fps, Monitoring image quality 1080p, Image motion detection each screen can set multiple detection areas and set 6 level sensitivities, Recording play back quality: 64 ch play back simultaneously, Region cover settings: Every channel can set 4 cover regions( IPC) support, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Back up way: Support U disk, USB mobile, HDD-16TB x 16, USB DVD-RW, network storage and back up, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, External Audio out put: 1 ch RCA, External network port: RJ 45(1), 10/100/1000 LAN port, RS455 port: Full duplex standard 485 port, USB port: USB3.0(1), 2.0(2), Wireless port: WiFi, Support Hot- Swappable tray x16,16TB x 16 HDDs (up to 256 TB), Each port supports MAX 16TB HDD. RAID 0, 1, 5, 6, 10 Wireless mouse. Approved Make: Axis,Sony, Infinova, Vivotek, Bosch, Pelco

2

1626100

813050

... More
OD213843/2023-2024:Supply and Installation of 10 TB Surveillance Hard Disk Drive. Approved Make: Barracuda, Seagate, WD

36

827917

22997.7

... More
OD216075/2023-2024:Supply, installation, testing and commissioning of Premium High speed 10 Mtr HDMI cable with Ethernet, Max Data rate: 18Gbps resolution: 4K @ 60Hz (4:4:4), Multi - Channel Audio support, High quality 24K gold-plated, corrosion-resistant and K-Lock Pull- Resistant connectors. Approved Model: Honeywell, Kramer

2

6736

3368.35

... More
OD216081/2023-2024:Supply, Installation, Testing and Commissioning of 190cm 4K UHD LED professional display having Resolution 3,840 x 2,160, input: HDMI, and USB ports, Power supply 100v-240v, 50/60Hz suitable for 24x7 operation, sound output minimum 20 watts, connecting cables as required. Additional swival type Wall mounting Kit. Approved Make: LG, Panasonic, Samsung, Sony.

2

306636

153318

... More
OD210789/2023-2024:Supply and Installation of 19 inch 24 port rack mountable 1U size complete Steel housing fully powder coated Light Interface Unit (LIU) with required number of SC connectors having FR grade Nylon Cable grommets, ABS Splice Trays with fully cushioned splice holder containing grooves for fixing splice protection sleeves, Cable Spools made up of flame retardant plastic, high impact resistance, stackable design for providing sufficient room for storage of excess cables, Blanking plates, etc. Including splicing charges. Approved Make: Commscope, Molex, R and M

1

13099

13099.61

... More
OD216129/2023-2024:Supply and Installation of Single mode double fiber Gigabit Optical Module, having capability of Switch to Switch interface ,Transmission distance up to 20 km,Speed 1 Gbps, Center Wavelength min 1310 nm sending; 1310 nm receiving, Output Optical Power -9.5 to -3, Supply Current 300mA max, Approved Make : Netgear ,HP, CISCO

20

154717

7735.87

... More
OD216131/2023-2024:Supply and providing SC-LC duplex patch cord 1 mtr. Approved make : Molex, R and M, Commscope, Belden

10

12776

1277.65

... More
OD210967/2023-2024:supply and Installation of unarmored 6 Core single mode Low Water Peak Outside plant (OSP) OFC having LSZH sheath, conforming to ITU-T G.655, IEC 60794-1 : 2001, IS 13882 (Part 1/Sec 1) : 1999 etc. Approved Make:- CommScope, Molex, R and M, Sterlite

600

35790

59.65

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

600

54570

90.95

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

900

98550

109.5

... More
OD210270/2023-2024:Supply and Providing of 19inch 9U Wall mounting Industrial Grade Powder coated weather proof network rack with front glass door and cooling fan with PDU, locks. Approved make: D-Link, Netrack, President, Valrack

9

75288

8365.37

... More
OD210491/2023-2024:Supply and Installation of 24 port Auto sensing 10/100/1000 Mbps PoE+ L2 Manageable Switch having 24 PoE+ port and 2 x1G SFP port, Switching capacity greater than 36Gbps, minimum CPU memory 512MB. Flash Memory 32MB dedicated PoE power delivery capacity ≥ 300W and support Static route and all other items required to complete the work , AC 230V power input. Approved Make: Cisco, Netgear, HP, Brocade, Allied Telesis

10

429755

42975.5

... More
OD210494/2023-2024:Supply and fixing CAT-6, 24 Port Enhanced Modular type Fully loaded Patch Panel with mounting plates, for interconnecting servers and clients, including termination charges. Approved Make: Commscope, Honeywell, Molex, R and M

10

67018

6701.86

... More
OD210966/2023-2024:Supply and installation of Optical fiber Splice enclosure termination box including splicing charge. Approved Make : Syntex

9

13173

1463.77

... More
OD216136/2023-2024:Supply, Store, Installation, Testing and Commissioning of OS2 fiber patch cord shall be SC to SC , Fiber Optic Patch Cords 3m, 9/ 125 micron, Cable Sheath shall be made of LSZH, Cable Diameter shall be 1.6 mm , Ferrule shall made of Ceramic., ROHS/ELV Compliant including splicing. Approved Make: Commscope, Nexans, R and M, Molex

10

12776

1277.65

... More
OD210953/2023-2024:Supply, Installation, testing and Commissioning of 1meter CAT 6 Patch cord. With LSZH Compliance. Approved Make: R and M, Molex, Panduit, Belden,Commscope

130

25188

193.76

... More
OD253299/2023-2024:Supply , laying, certification and documentation of 23 AWG copper conductor CAT-6A UTP 4 twisted pair sheathed copper wire cable that can support data transfer rates of up to 10 gigabits, cable having LSZH capability through the existing conduit and casing and capping as required. Approved Make: Actassi, Belden, R and M, Molex

5300

370364

69.88

... More
90.1.1.1:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm

2000

106920

53.46

... More
90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid

100

78413

784.13

... More
OD213783/2023-2024:Supply and installation of Outdoor IP Project Series Network PoE Bullet Vari-focal, Remote Focus camera having 2560x1920 (5MP) resolution, 1/2.8" Progressive CMOS or Better, ePTZ: 48x digital zoom , 120 dB or better WDR for Glare -free images lens 2.8 -12 mm vary focal zoom, low light performance down to 0.5 Lux (Color) or better, Dual stream support, video compression - H265/H264/H Smart Codec/ MJPEG sub stream, RJ-45(10/100 Base T ) Ethernet, Auto(ICR)/ Colour /Black& White, Protocol: IPv4/IPv6, HTTP, HTTPS, SSL, TCP/IP/UDP/UpnP, ICMP, IP Filter, ON VIF Profile S, Power source: DC 12V, PoE (802.3af) weather proof standard: IP 66 ingress protection, Metal Housing. Regulatory: CE FCC, UL & RoHS, Motion detection on Frame change recording, Interfaces:10 Base-T/100 Base-TX Ethernet (RJ-45), Onboard SD card Slot, Built-in IR illuminators, effective up to 50 meters or better. Approved Make: Sony, Axis, Vivotek ,Infinova, Sony, Bosch

43

1563262

36354.95

... More
OD213784/2023-2024:Supply and installation of Outdoor IP Project Series Network PoE Dome fixed Focus camera having 2560x1920 (5MP) resolution, 1/2.7" Progressive CMOS or Better, 120 dB or better WDR for Glare -free images Fixed-focal, low light performance down to 0.5 Lux (Color) or better, Dual stream support, video compression - H265/H264/H Smart Codec/ MJPEG sub stream, RJ-45(10/100 Base T ) Ethernet, Auto(ICR)/ Colour /Black& White, Protocol: IPv4/IPv6, HTTP, HTTPS, SSL, TCP/IP/UDP/UpnP, ICMP, IP Filter, ON VIF Profile S, Power source: DC 12V, PoE (802.3af) weather proof standard: IP 66 ingress protection, Metal Housing. Regulatory: CE FCC, UL & RoHS, Motion detection on Frame change recording, Interfaces:10 Base-T/100 Base-TX Ethernet (RJ-45), Onboard SD card Slot, Built-in IR illuminators, effective up to 30 meters with Smart IR, IR LED*2. Approved Make: Sony, Axis, Vivotek ,Infinova, Sony, Bosch

89

2262638

25422.91

... More
OD213830/2023-2024:Supply and installation of Outdoor IP Project Series Network PoE fixed Bullet camera having 2560x1920 (5MP) resolution, 1/2.7" Progressive CMOS or Better, 120 dB or better WDR for Glare -free images Fixed-focal, low light performance down to 0.5 Lux (Color) or better, Dual stream support, video compression - H265/H264/H Smart Codec/ MJPEG sub stream, RJ-45(10/100 Base T ) Ethernet, Auto(ICR)/ Colour /Black& White, Protocol: IPv4/IPv6, HTTP, HTTPS, SSL, TCP/IP/UDP/UpnP, ICMP, IP Filter, ON VIF Profile S, Power source: DC 12V, PoE (802.3af) weather proof standard: IP 66 ingress protection, Metal Housing. Regulatory: CE FCC, UL & RoHS, Motion detection on Frame change recording, Interfaces:10 Base-T/100 Base-TX Ethernet (RJ-45), Onboard SD card Slot, Built-in IR illuminators, effective up to 30 meters with Smart IR. Approved Make: Axis,Sony, Vivotek, Infinova

2

53168

26584.41

... More
OD257155/2023-2024:Supply and Installation of IP Network TDN Low-Light PTZ camera with auto tracking 1/2.8" Progressive CMOS or Better @25fps, triple stream, Min. Illumination required 0.6(color) &0.06Lux( B/W) or better, Max. Pixels 2560x1920 or Better, 5 Megapixels, IR Distance Distance up to 200m,triple , 4.9 ~ 148.2/4.3 ~ 129mm 30x Optical Zoom, Auto Focus, BLC,HLC, 3DNR, Electronic Defog, Electronic image stabilization, Privacy Mask, Internal/External illumination range with up to IR Range upto 200m distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 7 In & 2out, PoE, H.264 High Profile and MJPEG, PoE Class 3/ 12V DC/24VAC, IP 67, Having Operating temp range : (–10°C to 65°C). Certifications: ONVIF Profile S compliant, UL CSA60950-22, CE( EN 50130-4&EN 55022), FCC part 15& RoHS compliant. With all mounts and accessories required. Approved Make: Axis, Sony, Vivotek, Infinova,Sony, Bosch

2

401694

200847.13

... More
OD210775/2023-2024:Supply and Installation of Pole with min 6mtr height, 100mm diameter, fixed in a concrete footing of min height of 1mtr, properly finished with painting clamp, wire with Graphite based chemical compound earthing and enclosure suitable for the termination of cables etc.

5

79562

15912.55

... More
OD210793/2023-2024:Excavation of trench of size 40 x 60cm, sand cushioning up to a height of 25cm, refilling the trench etc. as required for laying the HDPE/PVC pipes wherever applicable.

100

46703

467.03

... More
OD210807/2023-2024:Supply and installation of 32mm HDPE Pipe for mechanical protection to Cables with nessasary junction boxes Approved Make: Tomes, Hycount

250

22467

89.87

... More
OD210954/2023-2024:Supply and fixing of 1 or 2 module modular PVC Box. Approved make: Finolex, Havels, Honeywell, Anchor

125

6097

48.78

... More
OD217207/2023-2024:Supply and fixing of water proof housing for bullet cameras fixing in pole. Approved make: Venteck, pelco

6

5081

846.98

... More
OD217255/2023-2024:Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 1200mm length , having a diameter of 14.2mm with copper bonding thickness of 254 microns minimum as per UL 467. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. . Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 &Omega;m. It should be free from hazardous substances. The mineral compound is required to have minimum 5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. FRP Earth electrode inspection chamber with weight bearing capacity of 5000kg. The dimension shall be 300mmx 300mmx 300mm. Govt approved Indian labs test certificate required. Approved Make: Cape, Erico, Furse, OBO.

1

11035

11035.4

... More
OD217256/2023-2024:Earth leads-supply and drawing 8 SWG bare copper conductor on the wall with necessary clamps with a spacing not exceeding 1 meter with necessary connections as required.

50

4680

93.6

... More
OD219811/2023-2024:Supply and Installation of Micro SD Card of 64GB having minimum 200mbps speed. Approved make:- Sandisk,Samsung

125

159706

1277.65

... More
OD219815/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved make : Raycap ,OBO,L and T

20

172562

8628.11

... More
OD219816/2023-2024:Integration, Testing, Commissioning, Documentation, Training. Supply and Installation of necessary Electrical accessories for the distribution of UPS power, and charging of UPS including Isolators, ELCBs, MCB, Sockets, Switches, Electrical PVC boxes etc.& all other switch gear with necessary accessories as per requirements. Approved Make: Legrand

1

19560

19560.77

... More
OD243025/2023-2024:Supply , laying, certification and documentation of fully Armored CAT-6 UTP cable through the HDPI pipe for connecting the camears in pole as required. Approved Make:- Actasi, Legrand, Belden, Panduit, R and M,Molex,Commscope

600

72738

121.23

... More
OD256478/2023-2024:Supply and installations of LCD/LED TV Wall Mount Stand 75 inch, 180 Degree Rotatable Bracket, Integrated cable management clip Steel construction Adjustment of perspective: Around 360 degrees Pan/Swivel: +/-360°/180° with all mounting fitting accessories. Approved Make : Prolegend

2

12416

6208.46

... More
OD257159/2023-2024:Supply and installation of Gigabit PoE+ injector suitable to connect the above Wi-Fi access point. Approved Make: Tenda, TP Link or equivalent

2

6620

3310.28

... More
OD257167/2023-2024:supply and installation of 3 core 2.5 sq mm armored copper cable having Copper conductor Type A PVC insulated cores color coded laid-up PVC tape inner sheathed GI WIRE armored Overall type ST1 PVC sheathed generally conforming to IS ;1554 [part-1]. Approved make : V Guard , Polycab

150

27322

182.15

... More
OD257177/2023-2024:Supply and Installation of PVC water proof box with rubber enclosure.Made for small DVR, POE switch, Fiber splicing box , IP 66 PVC plastic heavy duty material.3 Power socket for power supply.Lock and Key Protection .Pole moutable design. Can with stand a load upto 5kg. Approved Make: Gensec, Syntax

2

2090

1045.35

... More
PART-2 -EPABX(Electronics Work)

-

-

-

... More
OD225276/2023-2024:Supply. Installation and Commissioning of TEC approved ISDN compatible IVRS based Digital IP enabled EPABX expandable upto 240 extensions by adding line cards, initially equipped with: 1) 216 analog extension 2) 2 Digital Lines 3) 3 trunk Lines 4) Operator console - 2 Nos 5) SIP facility for 30 or more 6) DID Facility, welcome message facility with minimum 2 language choice 7) Hot Stand-by (Redundant CPU and Power supply unit) 8) MDF with Disconnection modules (Krone make) wired for ultimate capacity of the exchange with IPM protection module 9) IDF with Disconnection modules (krone make) wired for ultimate capacity of exchange Approved make: Matrix, Coral, Panasonic

1

477284

477284.13

... More
OD225278/2023-2024:Supply and Providing of 19inch 9U Wall mounting Industrial Grade Powder coated weather proof network rack with front glass door and cooling fan with PDU, locks. Approved make: D-Link, Netrack, President, Rittal, Valrack

1

8365

8365.37

... More
OD225280/2023-2024:Supply and laying or fixing 100 pair polyurethane insulated PVC telephone cable of conductor size 0.50 mm Annealed Tinned Copper (ATC) in the existing trench in the soil/built in trench/cable trays/supporting system etc. as required. Approved make: Finolex, RR Kabel

150

84300

562

... More
OD225284/2023-2024:Supply and fixing of group A, 1 module face plate on the 1 module PVC box and fixing one RJ 11 telephone jack with shutter in the face plate Approved Make: Legrand

150

60286

401.91

... More
OD225289/2023-2024:Supply and laying or fixing 50 pair polyurethane insulated PVC telephone cable of conductor size 0.50 mm Annealed Tinned Copper (ATC) in the existing trench in the soil/built in trench/cable trays/supporting system etc. as required. Approved make: Finolex, RR Kabel

450

146479

325.51

... More
OD225290/2023-2024:Supply and fixing of door type junction boxes with lock and fitted with Krone make modules for 100 pair. Approved Make :syntax

4

22357

5589.31

... More
OD225294/2023-2024:Supply and fixing of door type junction boxes with lock and fitted with Krone make modules for 50 pair. Approved Make :syntax

6

19597

3266.31

... More
OD225297/2023-2024:Supply and laying or fixing 50 pair polyurethane insulated jelly filled armored telephone cable of conductor size 0.50 mm Annealed Tinned Copper (ATC) in the existing trench in the soil/built in trench/cable trays/supporting system etc. as required. Approved make: Finolex, RR Kabel

100

31808

318.08

... More
OD225321/2023-2024:Supply and fixing of door type junction boxes with lock and fitted with Krone make modules for 20 pair. Approved Make : syntax

16

29012

1813.27

... More
OD225324/2023-2024:Supply and Installation of 20 pair PVC telephone cable having Conductor 0.5 mm diameter Annealed Tinned Copper (ATC) in the existing trench in the soil/built in trench/cable trays/supporting system etc. as required, Insulation Material High density polyethylene, Approved Make: Fenolex,RR kable

600

99444

165.74

... More
OD225325/2023-2024:Supply and fixing of door type junction boxes with lock and fitted with Krone make modules for 10 pair. Approved Make : syntax

7

10253

1464.82

... More
OD225344/2023-2024:Supply and Installation of 10 pair PVC telephone cable having Conductor 0.5 mm diameter Annealed Tinned Copper (ATC) in the existing trench in the soil/built in trench/cable trays/supporting system etc. as required, Insulation Material High density polyethylene, Approved Make: Fenolex,RR kabel

300

28815

96.05

... More
90.6.9.2:Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit2 pair

4000

185680

46.42

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1500

151725

101.15

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

400

43800

109.5

... More
OD225353/2023-2024:Supply, Installation, Testing and commissioning of Caller ID phones (DTMF) with glass epoxy PCB. Approved make : Beetel, Binatone, NEC, Panasonic.

150

235702

1571.35

... More
OD229465/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved make : Raycap ,OBO,L and T

2

17256

8628.11

... More
OD229466/2023-2024:Supply and installation of necessary electrical accessories for giving proper electrical power to the Rack : Approved make: Legrand

1

1742

1742.25

... More
PART-3-LAN(Electronics Work)

-

-

-

... More
OD245346/2023-2024:Supply and Installation of Rack mountable enterprises level firewall with the following specifications. Interfaces 16x1GbE, 3x10G SFP+, 2 USB 3.0, 1 Console, 1 Mgmt. port. Storage 64GB M.2, SSO Users 40,000, Access points supported (maximum) 512, Firewall inspection throughput 5.2 Gbps, Threat Prevention throughput 3.0 Gbps, Anti-malware inspection throughput 2.9 Gbps, Connections per second 21,000, Comprehensive Anti-Spam Service, Application Control, Capture Advanced Threat Protection, Certifications ICSA Enterprise Firewall, ICSA Antivirus, IPv6/USGv6, Common Access Card (CAC) Supported, Redundant Power Supply, Routing protocols BGP4, OSPF, RIPv1/v2, static routes, policy-based routing. Deep Packet Inspection services Gateway Anti-Virus, Anti-Spyware, Intrusion Prevention, DPI SSL. With 5 year DNS security. Approved Make: Sonicwall, Sophos

1

767659

767659.13

... More
OD217899/2023-2024:Supply and Providing of 19 inch, 42U Floor standing Industrial Grade Powder coated network rack with three sliding tray, front glass door and min 4 cooling fan with PDU 6/16A,12 socket single pole 32A MCB 6 sq mm 3m length including mounting kit , cable manager, Double side open with lock, Rolling wheels locks, Depth 1200mm width 800mm . Approved make: Netrack, President, Vallrack, Vertive.

1

81111

81111.24

... More
OD218055/2023-2024:Supply and Installation of Rack mountable server having the following specifications 2U Rack Model Power Edge R550 Intel Xenon Silver 4310 2.1G, 12C/24T,10.4 GT/s, 18M Cache, Turbo ,HT (120W) DDR4-2666 16DIMMS Open 3.5 inch Chassis with up to 8 Hard Drives 1*1.2 TB 10KRPM SAS 12Gbps 512n 2.5in Hot-plug Hard Drive PERC H 755 Controller Dual, Hot-plug, PSU (1+1),800,Mixed Mode iDRAC9, Standard Heat sink, CUS kit ,Memory upgrade 32GB-2RX4 DDR4 RDIMM 3200 MHz 8 GB Base, ,305in HYB CARR, Enterprise 5year Pro support, Resolution -next Business Day. Approved Make: Dell, HP

1

552781

552781.63

... More
OD217961/2023-2024:Supply and installation of L3 Fully managed 24 Port switch having 4x10Gigabit Ethernet 10GBase-T copper port, 24x10GigaBit Ethernet SFP+(Dedicated) Port, 1x Gigabit Ethernet Management port, Configuration of Layer 3 interface on physical port, Standard Rj -45 console port, Type -A USB slot on the front panel, Speed: 1.3 GHz CPU speed, 512 MB memory, Flash memory 256MB, Switching capacity 480Gbps or better, with Loopback detection. Configuration of VLAN as per department requirement. Approved Make: Cisco, Netgear, Allied Telesis, HP

2

699038

349519.13

... More
OD219058/2023-2024:Supply and Installation of 19 inch 24 port rack mountable 1U size complete Steel housing fully powder coated Light Interface Unit (LIU) with required number of SC connectors having FR grade Nylon Cable grommets, ABS Splice Trays with fully cushioned splice holder containing grooves for fixing splice protection sleeves, Cable Spools made up of flame retardant plastic, high impact resistance, stackable design for providing sufficient room for storage of excess cables, Blanking plates, etc. Including splicing charges. Approved make: Commscope, Molex, R and M, Sterlite,

4

52398

13099.61

... More
OD217909/2023-2024:Supply and Installation of Single mode double fiber Gigabit Optical Module, having capability of Switch to Switch interface ,Transmission distance up to 20 km,Speed 1 Gbps, Center Wavelength min 1310 nm sending; 1310 nm receiving, Output Optical Power -9.5 to -3, Supply Current 300mA max, Approved Make : Cisco,Netgear ,HP

75

580190

7735.87

... More
OD219831/2023-2024:Supply and providing SC-LC duplex patch cord 1 mtr. Approved make : Molex,R and M, Commscope

37

47273

1277.65

... More
OD217908/2023-2024:supply and Installation of unarmored 6 Core single mode Low Water Peak Outside plant (OSP) OFC having LSZH sheath, conforming to ITU-T G.655, IEC 60794-1 : 2001, IS 13882 (Part 1/Sec 1) : 1999 etc. Approved Make:- CommScope, Molex, R and M, Sterlite

1350

80527

59.65

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

700

63665

90.95

... More
OD217902/2023-2024:Supply and Providing of 19inch 9U Wall mounting Industrial Grade Powder coated network rack with front glass door and cooling fan with PDU, locks etc. Approved make: D-Link, Netrack, President, Rittal, Valrack

23

192403

8365.37

... More
OD211001/2023-2024:Supply and fixing CAT-6, 24 Port Enhanced Modular type Fully loaded Patch Panel with mounting plates, for interconnecting servers and clients, including termination charges. Approved Make: Molex, Actassi, R and M, Commscope.

35

234565

6701.86

... More
OD217898/2023-2024:Supply and Installation of 24 port Auto sensing 10/100/1000 Mbps PoE+ L2 Manageable Switch having 24 PoE+ port and 4 SFP port, Switching capacity ≥ 36Gbps, minimum CPU memory 512MB. Flash Memory32MB dedicated PoE power delivery capacity ≥ 300W and support Static route and all other items required to complete the work , AC 230V power input. Approved make: Cisco, Netgear, Allied Telesis, HP, Brocade

37

1717644

46422.83

... More
OD217903/2023-2024:Supply, Installation, testing and Commissioning of 1meter CAT 6 A Patch cord. With LSZH Compliance, Approved Make: R and M, Molex, Panduit, Beldon, Actassi

525

113919

216.99

... More
OD253296/2023-2024:Supply , laying, certification and documentation of 23 AWG copper conductor CAT-6A UTP 4 twisted pair sheathed copper wire cable that can support data transfer rates of up to 10 gigabits, cable having LSZH capability through the existing conduit and casing and capping as required. Approved Make:Actassi, Belden, R and M, Molex, Commscope

13000

908440

69.88

... More
OD211029/2023-2024:Supply and fixing of CAT6 Information Outlet for 1000 Mbps with spring shutter Faceplate + RJ45 I/O and keystone including termination charge with 1 or 2 module recessed with metal box should be restored with cement mixture and coated with white cement primer and keystone including termination charge. Approved Make: Molex, Actassi, Panduit, Beldon, R and M, Commscope.

500

365945

731.89

... More
OD217904/2023-2024:Supply, Installation, testing and Commissioning of 3 meter CAT 6A Patch cord. With LSZH Compliance, Approved Make: R and M, Molex, Panduit, Belden, Actassi, Commscope

500

132990

265.98

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

5000

505750

101.15

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

2000

219000

109.5

... More
90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid

200

156826

784.13

... More
OD219085/2023-2024:Charges for Testing, commissioning, Documentations and making permanent labeling at the I/O box and on the patch panel, Ferrule Wire Label on cable coming to the rack and in patch chord. including labour charges etc.

500

87115

174.23

... More
OD219325/2023-2024:Supply and installation of necessary electrical accessories for giving proper electrical power to the Rack Approved Make: Legrand

24

137163

5715.13

... More
OD219835/2023-2024:Supply and installation of Optical fiber Splice enclosure termination box including splicing charge. Approved Make : Syntex

23

33666

1463.77

... More
OD219836/2023-2024:Supply and Installation of LC-LC Patch chord for connecting the the Optical Fiber cable to the OFC Module. Approved make : Molex, Legrand ,Commscope

40

47859

1196.49

... More
OD219837/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved make : Raycap ,OBO,L and T

48

414149

8628.11

... More
OD241718/2023-2024:Supply and Installation of Wi-Fi Access points:- Indoor – Dual Band Frequency 2.4Ghz and 5Ghz 802.11ax(2x2), Supports wifi 6, Two (WAN/LAN) 10/100/1000 BASE-T Gigabit Ethernet (RJ-45) ports , Maximum Throughput 400/867Mbps (2.4Ghz and 5Ghz), Multi-User MIMO maximum 256 client devices , Antenna internal 3/4dBi, Wi-Fi Protected Access (WPA, WPA2), PoE power option with connecting CAT6 patch cords, and should be properly fixed as per site requirement, other accessories including AC power adaptor, Wall mounting Kit, etc. Approved Make: HP, Cisco, Netgear

22

1039415

47246.14

... More
OD257846/2023-2024:Charges for Tile cutting and restore ,making Good the damages including Labour charge, etc.

50

19692

393.85

... More
PART-4 -VIDEO CONFERANCING (Electronics Work)

-

-

-

... More
OD229408/2023-2024:Supply, Installation, Testing and commissioning of Small Form Factor micro tower CPU with minimum intel core i5 11th generation processor, 8GB RAM (2x4GB DDR4 nonECC), 1 TB HDD, on board WiFi and Blue tooth, OEM wireless keyboard and mouse, genuine microsoft Windows 10 - 64 bit OS, necessary mounting Bracket, 10 mtr CAT 6 Patch cord. Approved Make : Dell ,HP Acer

1

65044

65044

... More
OD229409/2023-2024:Supply, installation, testing and commissioning of USB Audio interface with full Duplex echo canceller with Automatic Echo cancellation and AGC, 3.5mm audio jacks for audio input and audio output, USB interface and supplied with necessary USB interface cable and external power adapter. Approved Model: Peoplelink,

1

58655

58655.75

... More
OD229413/2023-2024:Supply and Installation of on table boundary layer microphone having frequency response 40 Hz – 20 kHz, Max. sound pressure level 140 dB Polar pattern :cardioid, Sensitivity: 10 mV/Pa, impedence: 200 Ω ,Connector clip contact, trigger signal at the logic connector: Logic in (LED control), GND, Logic out (switch signal) Approved make: Shure, Senheiser

3

69690

23230

... More
OD229414/2023-2024:Supply. installation, testing and commissioning of USB PTZ camera with minimum 1OX optical zoom, 16X digital zoom, 1/2.7", CMOS Sensor, 58.5° Horizontal Field of View, +170 Horizontal Rotation range. -30° 90° Vertical Rotation Range, minimum 64 presets, Windows 7, Windows 8, Windows 10, Mac|OS X. Linux, Android support, USB interface. working on 12V DC, IR remote controller for Pan.Tilt and Zoom. supplied with necessary camera mounting stand and USB cable. Approved Model: PeopleLink

1

54125

54125.9

... More
OD229418/2023-2024:Supply and installation of 10 channel Mixer having following specification - 10 Line Inputs (4 mono, 3 stereo) and minimum 4 microphone inputs with 48-volt phantom power, high pass filter for each channel, Outputs - two or more stereo outputs, monitor output, one auxiliary, one head phone out, One Knob compressor with LED indicators, USB Digital audio interface, robust and built into an impact resistant powder-coated metal chassis. Power Adapter for Mixer. Approved Model: Yemaha,Behringer, Soundcraft

1

25785

25785.3

... More
OD229422/2023-2024:Supply and Installation of High Speed HDMI 2.0 Cable support 4K @60Hz/30Hz with 5 meter length having 24K gold plated connector high purity oxygen free copper conductor, Transfer digital audio and video signals at high speed of 10.2 GBPS. Approved Make: Honey well, Kramer

1

1810

1810.78

... More
OD229425/2023-2024:Supply, Installation, Testing and Commissioning of 75” 4K UHD LED TV having Resolution 3,840 x 2,160, input:: HDMI, and USB ports, Power supply 100v-240v, 50/60Hz, sound output minimum 20 watts, connecting cables as required. Additional swival type Wall mounting Kit. Approved make: Samsung/SONY/Panasonic/LG

1

153318

153318

... More
OD253302/2023-2024:Supply and Installation of Wireless Handheld Microphone , Type : dynamic; Frequency response : 50 to 16,000 Hz (–3 dB) ; THD( total harmonic distortion) : ≤ 0.9% ; Pick-up pattern: cardioid ; Signal-to-noise ratio : ≥ 103 dBA ;RF output power : 10 mW ; Switching bandwidth up to 24 MHz ; Operating time approx. : 10 hrs ; Modulation wideband : FM ; Frequency : 8 frequency banks, each with up to 12 factory-preset channels ; Input sensitivity : 1.5 mV / Pa ; Receiver Principle : double superheterodyne ; Diversity principle : True Diversity or Better. Approved Make: Sennheiser, Shure

2

116916

58458.44

... More
OD229432/2023-2024:Supply and Installation of Wall mount compact, High fidelity powered Speaker - having Rated power 100Watts ,Inputs: 1 x XLR (mic/line), 1 x 1/8"" Frequency Response - 60Hz-23kHz, Sensitivity - 88 ± 3dB (1W, 1M), 5.5"" woofer and 1/2"" tweeter.Aux input: 3.5 mm mini jack,Built-in switching power supply 100-240 V, ~50/60 Hz etc. Approved make:Audac, JBL,Apart, Bheringer

2

53429

26714.5

... More
OD229449/2023-2024:Supply, laying, testing and commissioning of professional Audio cable with termination as per the site requirement. Approved make: Cosmo,beldon,Chethan

60

12683

211.39

... More
OD229454/2023-2024:Supply and Installation of Camera wall mount having Thickness 10 mm ,Transparent plexiglass or black plexiglass base,Attachment clips in aluminium, Screw Directly fixed to the wall. Preferred Make: Axeos or equivalent

1

2323

2323

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

150

13642

90.95

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

150

15172

101.15

... More
OD229471/2023-2024:Supply and Providing of 19inch 9U Wall mounting Industrial Grade Powder coated weather proof network rack with front glass door and cooling fan with PDU, locks. Approved make: D-Link, Netrack, President, Rittal, Valrack

1

8365

8365.37

... More
OD240713/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved make : Raycap ,obo,L and T

2

17256

8628.11

... More
OD260854/2023-2024:Supply and installations of LCD/LED TV Wall Mount Stand 75 inch, 180 Degree Rotatable Bracket, Integrated cable management clip Steel construction Adjustment of perspective: Around 360 degrees Pan/Swivel: +/-360°/180° with all mounting fitting accessories. Approved Make: Prolegend

1

6208

6208.46

... More
PART-5-PUBLIC ADDRESS SYSTEM(Electronics Work)

-

-

-

... More
OD245204/2023-2024:Supply and Installation of 120Watts Mixer amplifier with 3 balanced MIC and 2 unbalanced AUX inputs, Frequency Response 50 - 20,000 Hz (±3 dB), Distortion 1% or less at 1 kHz 1/3 rated power, S/N ratio of over 60 dB, AC mains or 24 V DC power operation. Output Speaker out: Balanced (floating),High impedance: 83 Ω (100 V), 42 Ω (70 V), Low impedance: 4 Ω (22 V). Approved Make: Toa , Apart, Quest

24

971764

40490.17

... More
OD245218/2023-2024:Supply and Installation of High quality 2-way wall mount speaker in a bass reflex enclosure, 100V-transformer, 12 cm cone Woofer and 2.5 cm dome tweeter, SPL 90 dB (1 W, 1 m), Frequency Response 80 Hz - 20 kHz, Rated Input 30 W, 100 V line: 30W/20 W/15W/10W/5W, ABS enclosure with removable metal grille with U-brackets for tilt and pan, protection IPX4. Approved Make: Toa, Apart, Quest

46

464407

10095.82

... More
OD245266/2023-2024:Supply and Installation of gooseneck microphone with condenser unidirectional cardioid capsule, Frequency response 50 Hz to 16 kHz, Rated impedance 750 ohm, balanced, sensitivity shall be –41 dB +/-3dB (1 kHz 0 dB=1 V/Pa), LED light ring, 2 flexible microphone shaft with copper alloy and black paint, balanced XLR-3 output, phantom power source supplying 9 – 52 volts or 2 x “AA” battery, windshield, XLR to Phone Jack Cable etc. Approved Make: Toa, shure, Bosch

50

504791

10095.82

... More
OD224583/2023-2024:Supply and Installation of 48v Phantom power supply having Mic Inputs 2 x Female XLR, Mic Outputs 2 x Male XLR (For Amplifier),Compliance IS616:2017 (BIS Certified). Approved Make: Yamaha,

23

141586

6155.95

... More
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm

1000

50100

50.1

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1000

101150

101.15

... More
OD224603/2023-2024:Supply and fixing of 19" 6U wall mount rack for switches with cable manager and hardware mounting kit. Approved make: Rittal, Valrack, Netrack, President

23

142367

6189.88

... More
OD224614/2023-2024:Supply and installation of 2 core shielded microphone cable having Polyethylene Insulation, Bare copper braid Shield, Bare Copper Conductor. Approved Make: Belden, Kramer

650

67346

103.61

... More
OD224615/2023-2024:Supply and installation of XLR Connectors for connecting the Microphone to the Mixer. Approved Make: Neutrik

92

27697

301.06

... More
OD224746/2023-2024:Supply and installation of necessary electrical accessories for giving proper electrical power to the Rack Approved Make: Legrand

23

40071

1742.25

... More
OD245272/2023-2024:Supply and installation of Speaker Cable with necessary RCA jacks Approved Make:- Belden, Kramer

1000

127910

127.91

... More
OD245289/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved make : Raycap ,OBO,L and T

46

396893

8628.11

... More
PART-6-COURT PROCEEDINGS RECORDING(Electronics Work)

-

-

-

... More
OD239713/2023-2024:Supply and Installation of Digital Audio processor with 8 x Analogue Input Channels and 8 x Analogue Output Channels, should have built-in automatic mixing console, optional feedback elimination, echo cancellation, noise cancellation module, Matrix mixing of input and output signals, with automatic camera tracking function, It should have minimum 1 x RS232 , 1 x RS485 and 8 x GPIO port, It should support AGC, AEC, ANC, and AFC,and Independently controlled 48V Phantom Power Per Channel, The processor should support MIC/LINE, Input/Output ,The frequency response should be between 20Hz- 20 KHz, ±0.2dB,The processor should have Multi-point filtering techniques and multi-sub-band frequency shifting , should support Scene pre-sets and recalling, and with 31-band graphic equalizer, delay, crossover, limiter, it should be controlled via touch panel. The processor should be rack mountable and in 1U size. Approved Make Audio Technica, Shure,Norden, JBL

1

180567

180567.07

... More
OD239765/2023-2024:Supply and Installation of Wired Desktop Condenser Microphone with support of 48V phantom power and battery, Micro Tube length of 455mm.sensitivity of -45dB±2dB .The Frequency response should be between 30Hz-20kHz,with all mounting accessories are needed. Approved Make Audio Technica,Shure,Norden,JBL

6

109783

18297.25

... More
OD239773/2023-2024:Supply and Installation of Control Touch panel, should be with minimum 5.5inch TFT LCD display having capacitive touch screen with a minimum resolution of 800*480px,64K colors , 16-Bit RGB and a brightness of 300 cd/? .It should have minimum 1 x 10/100 RJ45 with PoE supported and RS485 connector. It should support TCP/IP protocol, quick scene control switching, volume control, and playback control from Processor. It should be Desktop/Wall mounting Type. Approved Make Audio Technica, Shure,Norden,JBL

1

72919

72919.11

... More
OD239779/2023-2024:Supply and Installation of outdoor wall mount speaker 20 W with Frequency Response of 120Hz - 20KHz, Sensitivity 83dB±2dB and Maximum SPL ≥93dB. Approved Make Tannoy, Norden,TOA,JBL

2

35846

17923.25

... More
OD239780/2023-2024:Supply and Installation of Powered wall mount speaker 2X30 W with Frequency Response of 20Hz - 20KHz,Sensitivity 90dB±2dB and Maximum SPL ≥104dB, Approved Make Tannoy, TOA, Norden,JBL

1

41059

41059.17

... More
OD239793/2023-2024:Supply and Installation of 120W 5 Input Mixer amplifier with 3 Microphone inputs and 2 AUX inputs. Mic 1 is provided with priority and muting functions. Bass and treble controls and master volume control. Frequency response of 50Hz -16kHz (±3dB) and Total harmonic distortion of < 1% (1kHz , 1/3 rated output voltage). Approved Make Kramer, Norden,Lab Gruppen , JBL

1

45879

45879.25

... More
OD240016/2023-2024:Supply and Installation of PTZ Video conference Camera : Minimum 12X Optical Zoom; Iris: f=4.4mm~52.8mm; Horizontal angle of view : 71°~8.2° and vertical angle of view : 42.7°~4.5° , Sensor:1 /2.5inch or better CMOS sensor; Pixels:8.5 Mega Pixel or higher; Preset Number:255 or more; Horizontal Rotation:+ 170° Vertical Rotation :-30°~ to 90°; Pan Control Speed: 1.7° ~ 100°/second; Tilt Control Speed : 1.7° ~ 69.9°/second; Supported Video Resolution : 4KP60fps, 4KP29.97fps, 4KP25, 1080P30, 1080P29.29, 1080P25 Minimum illumination:0.5 Lux or higher; DNR:2D & 3D DNR; White Balance :Auto/Manual; Supported Protocol : TCP/IP, HTTP,RTSP, RTMPS, Onvif, DHCP, Multicast, Interface: HDMI, 10/100M Base-T PoE port ,3.5mm Audio In , Type-C usb , Communication interface : RS485 Video Compression Format:MJPEG/H.264/H.265 ; Support Auto framing , remote control , Support USB 5V power supply, 12V Adapter and PoE power supply Control Protocol: VISCA/PELCO-D/Pelco-P; support Dual stream Video Bitrate : 32kbps ~ 102400kbps. Approved Make KRAMER, NORDEN, Panasonic, JBL

3

443333

147777.79

... More
OD240022/2023-2024:Supply, Installation, Testing and Commissioning of 43 INCH 4K UHD LED TV having Resolution 3,840 x 2,160, input:: HDMI, and USB ports, Power supply 100v-240v, 50/60Hz, sound output minimum 20 watts, 16*7 operation, connecting cables as required. Additional swivel type Wall mounting Kit. Approved Make Samsung/SONY/Panasonic

1

40652

40652.5

... More
OD240028/2023-2024:Supply, Installation, testing and commissioning of >=22 inch LED full HD monitor with 16x7 operation HDMI , power supply 100v-240v, 50/60hz, connecting cables as required. wall mounting kit.Approved Make LG/Samsung

1

11615

11615

... More
OD240633/2023-2024:Supply and installation of 1080p IR Bullet camera with 1/2.8-inch CMOS sensor with 4MP resolution or higher, Color: 0.001 lux @ F1.6, B/W: 0 lux with IR , 120dB WDR, Max. Resolution of 2560x1440 p,H.265+, H.265, H.264 streams with 30m IR, Digital Noise Reduction, Smart Defog, Rule based alarms and tracking, Intrusion Crossline ,Motion Detection, Tampering (Masking), IP Address Conflict, Pre/Post Alarm Recording, Alarm Recording/Snapshot, Audio detection (if microphone used),4 region Privacy Masking, Alarm Input 1/1, Audio Input/output, RJ45, G.711, Signal-to-Noise Ratio 52dB, ONVIF Profile S,G and T, IP67, IK10, PoE, CE, FCC, UL certified. SD card support up to 512GB. Approved Make Norden, Bosh, Vivotek, Panasonic

1

21413

21413.41

... More
OD240638/2023-2024:Supply and Installation of Network Video recorder with minimum 32 channel ,embedded with Linux and can be monitored through free VMS. Should support 8 SATA hard disk slot and each should support 10TB HDD, Should JBOD & RAID 0, 1, 5, 6, 10.Should support H.265+, H.265, H.264 compression. Should Supports data transfer via USB & Network for easy and fast backup of data though NFS. Should be UL 62368-1, CE, FCC, RoHS and BIS certified. Approved Make Norden, Bosh, Vivotek, Panasonic

1

130355

130355.29

... More
OD240641/2023-2024:Supply and Installation of Desktop PC with Core i5 or Amd Ryzen5 with 3.5 Ghz+ clock and minimum 6 physical cores recommended , Minimum RAM of 16GB, Minimum 256 GB NVME SSD; Sound card, windows/Ubuntu operating system, - GPU: min GTX 1660 with at least 600 cuda cores, HDMI/DP (Total 4 nos ports )output ports With Keyboard, mouse. Should be capable of running video streaming software of High-performance real-time video/audio capturing and mixing. webcams, capture cards, and more. Approved Make Hp, Lenovo,Asus, Dell

1

116684

116684.57

... More
OD240661/2023-2024:Supply and Installation of 8 TB Surveillance Hard Disk Drive. Approved Make Barracuda, Seagate, WD

2

39026

19513.2

... More
OD240662/2023-2024:Supply and Installation of 24 port Auto sensing 10/100/1000 Mbps PoE+ L2 Manageble Switch having 24 PoE+ port and 2 x1G SFP port, Switching capacity ≥ 36Gbps, minimum CPU memory 128MB. Flash Memory32MB dedicated PoE power delivery capacity ≥ 300W and support Static route and all other items required to complete the work , AC 230V power input. Approved Make Netgear, Allied Telesis, Cisco, HP

1

38329

38329.5

... More
OD240683/2023-2024:Supply and Installation of Wi-Fi Access points:- Indoor – Dual Band - Dual concurrent radio controller based thin access point with - Frequency 2.4Ghz and 5Ghz, Two (WAN/LAN) 10/100/1000 BASE-T Gigabit Ethernet (RJ-45) ports , Wireless Mode 802.11ac (2x2), Maximum Throughput 400/867Mbps (2.4Ghz and 5Ghz), Multi-User MIMO, Antenna internal 3/4dBi, Wi-Fi Protected Access (WPA, WPA2), PoE power option with connecting CAT6 patch cords, and should be properly fixed as per site requirement, other accessories including AC power adaptor, Wall mounting Kit, etc. Approved Make Cisco, Netgear

1

13008

13008.8

... More
OD240687/2023-2024:Supply and Providing of 19inch 9U Wall mounting Industrial Grade Powder coated weather proof network rack with front glass door and cooling fan with PDU, locks. Approved Make D-Link, Netrack, President, Rittal, Wallrack

1

8365

8365.37

... More
OD240688/2023-2024:Supply and fixing CAT-6, 24 Port Enhanced Modular type Fully loaded Patch Panel with mounting plates, for interconnecting servers and clients, including termination charges. Approved Make Molex, Actassi, R&M.

1

6701

6701.86

... More
OD240695/2023-2024:Supply, Installation, testing and Commissioning of 1meter CAT 6 Patch cord. With LSZH Compliance, Approved Make R and M, Molex, Panduit, Beldon, Actassi

4

775

193.76

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

175

17701

101.15

... More
OD240699/2023-2024:Supply and Installation of 2 core audio cable with 2-10 AWG highly flexible stranded bare copper conductors with PVC insulation, PVC jacket with ripcord. Approved Make Belden

150

18990

126.6

... More
OD240701/2023-2024:Supply , laying, certification and documentation of 23 AWG CAT-6 UTP 4 twisted pair sheathed copper wire cable that can support data transfer rates of up to 1 gigabits,cable having LSZH capability through the existing conduit and cassing and capping as required. Approved Make Actassi, Belden, R&M, Molext

175

10316

58.95

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

5475

109.5

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

100

9095

90.95

... More
OD240702/2023-2024:Supply and installation of 2 core shielded microphone cable having Polyethylene Insulation, Bare copper braid Shield, Bare Copper Conductor. Approved Make Ahuja, Belden

100

8038

80.38

... More
OD240703/2023-2024:Supply and installation of necessary electrical accessories for giving proper electrical power to the Rack :

1

1742

1742.25

... More
OD240704/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved Make Raycap ,obo,L&T

2

17256

8628.11

... More
OD240707/2023-2024:Charges for Tile cutting and restore ,making Good the damages including Labour charge, etc.

15

5907

393.85

... More
PART-7-VULNERABLE WITNESS DEPOSITION CENTRE(Electronics Work)

-

-

-

... More
OD241849/2023-2024:Supply and Installation of Digital Audio processor with 8 x Analogue Input Channels and 8 x Analogue Output Channels, should have built-in automatic mixing console, optional feedback elimination, echo cancellation, noise cancellation module, Matrix mixing of input and output signals, with automatic camera tracking function, It should have minimum 1 x RS232 , 1 x RS485 and 8 x GPIO port, It should support AGC, AEC, ANC, and AFC,and Independently controlled 48V Phantom Power Per Channel, The processor should support MIC/LINE, Input/Output ,The frequency response should be between 20Hz- 20 KHz, ±0.2dB,The processor should have Multi-point filtering techniques and multi-sub-band frequency shifting , should support Scene pre-sets and recalling, and with 31-band graphic equalizer, delay, crossover, limiter, it should be controlled via touch panel. The processor should be rack mountable and in 1U size. Approved Make Audio Technica, Shure,Norden, JBL

1

180567

180567.07

... More
OD241857/2023-2024:Supply and Installation of Wired Desktop Condenser Microphone with support of 48V phantom power and battery, Micro Tube length of 455mm.sensitivity of -45dB±2dB .The Frequency response should be between 30Hz-20kHz,with all mounting accessories are needed. Approved Make Audio Technica,Shure,Norden,JBL

5

91486

18297.25

... More
OD241869/2023-2024:Supply , installation, testing and commissioning of High Fidelity Wall Mounted type Microphone with voice pick up range of 5 -100 sq.m and sensitivity of -40dB plus or minus 2dB .The Frequency response should be between 20Hz-20kHz, with all mounting accessories Approved Make Audio Technica, Shure, Norden, JBL

1

13252

13252.99

... More
OD241895/2023-2024:Supply and Installation of Control Touch panel, should be with minimum 5.5inch TFT LCD display having capacitive touch screen with a minimum resolution of 800*480px,64K colors , 16-Bit RGB and a brightness of 300 cd/? .It should have minimum 1 x 10/100 RJ45 with PoE supported and RS485 connector. It should support TCP/IP protocol, quick scene control switching, volume control, and playback control from Processor. It should be Desktop/Wall mounting Type. Approved Make Audio Technica, Shure,Norden,JBL

1

72919

72919.11

... More
OD241904/2023-2024:Supply and Installation of Powered wall mount speaker 2X30 W with Frequency Response of 20Hz - 20KHz,Sensitivity 90dB±2dB and Maximum SPL ≥104dB, Approved Make Tannoy, TOA, Norden,JBL

1

41059

41059.17

... More
OD241906/2023-2024:Supply and Installation of outdoor wall mount speaker 20 W with Frequency Response of 120Hz - 20KHz, Sensitivity 83dB+-2dB and Maximum SPL ≥93dB. Approved Make Tannoy, Norden,TOA,JBL

2

35846

17923.25

... More
OD241910/2023-2024:Supply and Installation of 120W 5 Input Mixer amplifier with 3 Microphone inputs and 2 AUX inputs. Mic 1 is provided with priority and muting functions. Bass and treble controls and master volume control. Frequency response of 50Hz -16kHz (±3dB) and Total harmonic distortion of < 1% (1kHz , 1/3 rated output voltage). Approved Make Kramer, Norden,Lab Gruppen , JBL

1

45879

45879.25

... More
OD241960/2023-2024:Supply and Installation of PTZ Video conference Camera : Minimum 12X Optical Zoom; Iris: f=4.4mm~52.8mm; Horizontal angle of view : 71°~8.2° and vertical angle of view : 42.7°~4.5° , Sensor:1 /2.5inch or better CMOS sensor; Pixels:8.5 Mega Pixel or higher; Preset Number:255 or more; Horizontal Rotation:+ 170° Vertical Rotation :-30°~ to 90°; Pan Control Speed: 1.7° ~ 100°/second; Tilt Control Speed : 1.7° ~ 69.9°/second; Supported Video Resolution : 4KP60fps, 4KP29.97fps, 4KP25, 1080P30, 1080P29.29, 1080P25 Minimum illumination:0.5 Lux or higher; DNR:2D & 3D DNR; White Balance :Auto/Manual; Supported Protocol : TCP/IP, HTTP,RTSP, RTMPS, Onvif, DHCP, Multicast, Interface: HDMI, 10/100M Base-T PoE port ,3.5mm Audio In , Type-C usb , Communication interface : RS485 Video Compression Format:MJPEG/H.264/H.265 ; Support Auto framing , remote control , Support USB 5V power supply, 12V Adapter and PoE power supply Control Protocol: VISCA/PELCO-D/Pelco-P; support Dual stream Video Bitrate : 32kbps ~ 102400kbps. Approved Make KRAMER, NORDEN, Panasonic, JBL

4

591111

147777.79

... More
OD241974/2023-2024:Supply, Installation,testing and commissioning of 32" LED full HD disply with 16x7 operation HDMI and USB, power supply 100v-240v, 50/60hz, including necessary wall mounting kit, mouse and connecting cables as required. Approved Make LG/samsung/panasonic/sony

1

27737

27737.78

... More
OD241978/2023-2024:Supply, Installation, Testing and Commissioning of 43 INCH 4K UHD LED TV having 16x7 operation,Resolution 3,840 x 2,160, input:: HDMI, and USB ports, Power supply 100v-240v, 50/60Hz, sound output minimum 20 watts, connecting cables as required. Additional swivel type Wall mounting Kit. Approved Make Samsung/SONY/Panasonic

1

40652

40652.5

... More
OD241996/2023-2024:Supply, Installation, Testing and Commissioning of 55” 4K UHD LED TV having 16x7 operation, Resolution 3,840 x 2,160, input:: HDMI, and USB ports, Power supply 100v-240v, 50/60Hz, sound output minimum 20 watts, connecting cables as required. Additional swivel type Wall mounting Kit. Approved Make Samsung/SONY/Panasonic

1

65044

65044

... More
OD242114/2023-2024:Supply and Installation of trolley stand with wheels for Video conferencing system having the capacity to hold >55 inch display, provision for holding the camera, Material ‎Alloy Steel, Floor Mounting Type.

1

11034

11034.25

... More
OD242139/2023-2024:Supply and Installation of Desktop PC with Core i5 or Amd Ryzen5 with 3.5 Ghz+ clock and minimum 6 physical cores recommended , Minimum RAM of 16GB, Minimum 256 GB NVME SSD; Sound card, windows/Ubuntu operating system, - GPU: min GTX 1660 with at least 600 cuda cores, HDMI/DP (Total 4 nos ports )output ports With Keyboard, mouse. Should be capable of running video streaming software of High-performance real-time video/audio capturing and mixing. webcams, capture cards, and more. Approved Make Hp, Lenovo,Asus, Dell

1

116684

116684.57

... More
OD242140/2023-2024:Supply and Installation of Network Video recorder with minimum 32 channel ,embedded with Linux and can be monitored through free VMS. Should support 8 SATA hard disk slot and each should support 10TB HDD, Should JBOD & RAID 0, 1, 5, 6, 10.Should support H.265+, H.265, H.264 compression. Should Supports data transfer via USB & Network for easy and fast backup of data though NFS. Should be UL 62368-1, CE, FCC, RoHS and BIS certified. Approved Make Norden, Bosh, Vivotek, Panasonic

1

130355

130355.29

... More
OD242141/2023-2024:Supply and installation of 1080p IR Bullet camera with 1/2.8-inch CMOS sensor with 4MP resolution or higher, Color: 0.001 lux @ F1.6, B/W: 0 lux with IR , 120dB WDR, Max. Resolution of 2560x1440 p,H.265+, H.265, H.264 streams with 30m IR, Digital Noise Reduction, Smart Defog, Rule based alarms and tracking, Intrusion Crossline ,Motion Detection, Tampering (Masking), IP Address Conflict, Pre/Post Alarm Recording, Alarm Recording/Snapshot, Audio detection (if microphone used),4 region Privacy Masking, Alarm Input 1/1, Audio Input/output, RJ45, G.711, Signal-to-Noise Ratio 52dB, ONVIF Profile S,G and T, IP67, IK10, PoE, CE, FCC, UL certified. SD card support up to 512GB. Approved Make Norden, Bosh, Vivotek, Panasonic

1

21413

21413.41

... More
OD242474/2023-2024:Supply and Installation of 8 TB Surveillance Hard Disk Drive. Approved Make Barracuda, Seagate, WD

2

39026

19513.2

... More
OD242552/2023-2024:Supply and Installation of 24 port Auto sensing 10/100/1000 Mbps PoE+ L2 Manageble Switch having 24 PoE+ port and 2 x1G SFP port, Switching capacity ≥ 36Gbps, minimum CPU memory 128MB. Flash Memory32MB dedicated PoE power delivery capacity ≥ 300W and support Static route and all other items required to complete the work , AC 230V power input. Approved Make Netgear, Allied Telesis, Cisco, HP

1

38329

38329.5

... More
OD242645/2023-2024:Supply and fixing CAT-6, 24 Port Enhanced Modular type Fully loaded Patch Panel with mounting plates, for interconnecting servers and clients, including termination charges. Approved Make Molex, Actassi, R&M

1

6701

6701.86

... More
OD242656/2023-2024:Supply and Providing of 19 inch17U Floor mounting Industrial Grade Powder coated weather proof network rack with one sliding tray ,front glass door and cooling fan with PDU, Double side open with lock, Rolling wheels locks, Approved Make D-Link, Netrack, President, Rittal, Wallrack

1

21990

21990.89

... More
OD242659/2023-2024:Supply and Installation of Wi-Fi Access points:- Indoor – Dual Band - Dual concurrent radio controller based thin access point with - Frequency 2.4Ghz and 5Ghz, Two (WAN/LAN) 10/100/1000 BASE-T Gigabit Ethernet (RJ-45) ports , Wireless Mode 802.11AX(WiFi 4/WiFi 5/WiFi 6/WiFi 6E) ,Throughput rate 2.4 GHz573.5 Mbps,5 GHz4.8 Gbps 6 GHz4.8 Gbps, Wave 2 2x2: 3 MU-MIMO radios, Multi-User MIMO, Antenna internal 2.4 GHz3.2 dBi 5 GHz5.3 dBi 6 GHz6 dBi, Wi-Fi Protected Access (WPA, WPA2), PoE power option with connecting CAT6 patch cords, and should be properly fixed as per site requirement, other accessories including AC power adaptor, Wall mounting Kit, etc. Approved Make Ubiquiti, Netgear

1

24926

24926.07

... More
OD242663/2023-2024:Supply, Installation, testing and Commissioning of 1meter CAT 6 Patch cord. With LSZH Compliance, Approved Make R and M, Molex, Panduit, Beldon, Actassi

8

1550

193.76

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

60

5457

90.95

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

120

12138

101.15

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

120

13140

109.5

... More
OD242670/2023-2024:Supply and Installation of 2 core audio cable with 2-10 AWG highly flexible stranded bare copper conductors with PVC insulation, PVC jacket with ripcord. Approved Make Belden

150

18990

126.6

... More
OD242675/2023-2024:Supply , laying, certification and documentation of 23 AWG CAT-6 UTP 4 twisted pair sheathed copper wire cable that can support data transfer rates of up to 1 gigabits,cable having LSZH capability through the existing conduit and cassing and capping as required. Approved Make Actassi, Belden, R and M, Molex

150

8842

58.95

... More
OD242714/2023-2024:Supply and installation of DTP Transmitter and Receiver for HDMI with XTP DTP 24 shielded twisted pair cable of min 30 m length including shielded RJ 45 plugs jacks etc for the extension of HDMI port of NVR to the main Display Approved Make Aten, Extron, Crestron

1

30106

30106.63

... More
OD242722/2023-2024:Supply and installation of Speaker Cable with necessary RCA jacks Approved Make Belden, Kramer

70

8953

127.91

... More
OD242996/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved Make Raycap ,obo,L&T

2

17256

8628.11

... More
OD243004/2023-2024:Supply and installation of necessary electrical accessories for giving proper electrical power to the Rack : Approved Make: Legrand

1

1742

1742.25

... More
OD243007/2023-2024:Charges for Tile cutting and restore ,making Good the damages including Labour charge, etc.

5

1969

393.85

... More
PART-8-CONFERANCE SYSTEM(Electronics Work)

-

-

-

... More
OD233721/2023-2024:Supply and Installation of 2 way speaker with 1inch dome tweeter and a 4inch Mid /Low-frequency driver, RMS Power 35 W, Max. Power 70 W, Impedance 8ohm , 24/12/6W@100V, Sensitivity (1W/1m) 86 dB, SPL 100dB @100V, Frequency Response (± 3 dB) 100 Hz - 20 kHz Range (-10 dB) 65 Hz - 20 kHz Dispersion 130° (H xV) designed Vertical& Horizontal mounting bracket. Approved Make Audac,Polk audio

8

100132

12516.5

... More
OD233725/2023-2024:Supply and Installation of Quad channel 4 Ohm Class-D amplifier - 4 x 80W - 70/100V, Energy star certified, Signal / Noise > 100 dB, THD+N (@ 1 kHz) < 0.05% (1/8 rated Power), Crosstalk (@ 1 kHz) < 70 dB, protection for DC/Overload/Over Heat/ signal limit. Approved Make Audac, Apart,Toa

1

80097

80097.32

... More
OD233743/2023-2024:Supply and Installation of 12-Input Mic/Line Rack mountable Mixer having 8 Mic Preamps, 2-band Eqs, 2 stereo Line Inputs, Switchable +48 V phantom power for condenser microphones, Mic Signal-to-noise ratio: -110 dB / -112 dB A-weighted, Signal-to-noise ratio: 110 dB / -112 dB A-weighted etc. Approved Make Behringer, Yamaha

1

33056

33056.57

... More
OD233747/2023-2024:Supply and Installation of conference Control unit with Intuitive LED indicators, Web browser, System control for up to 80 Discussion Devices, Plus/minus buttons and green LED indicators for setting the volume range, open/override/voice activation and PTT , Built-in digital recorder with internal memory and USB recording, loudspeaker and headphone socket for listening to recordings, DBFS ,USB, Controller shall have Sample rate 44.1kHz, Nominal input (85 db SPL) <0.5%,Max. input (110 db SPL) <0.5%. Approved Make Bosch, Shure

1

253114

253114.63

... More
OD233753/2023-2024:Supply and Installation of Table top Chairman unit with Plug-and- play functionality, priority button, chairperson’s microphone shall be activated when the priority button is pressed, all currently active participant microphones shall be muted, a chime shall be sounded to announce that the chairperson is about to speak, built in Loudspeaker and headphone socket with level control, GSM immunity. Color-coded light-ring indicator in head of microphone, priority Length of microphone from mounting surface 480 mm (18.9 in), Red indicates microphone is active, white indicates possible to speak, green indicates request to speak and flash green indicates next in line to speak. Approved Make Bosch, Shure

1

50943

50943.67

... More
OD233760/2023-2024:Supply and Installation of Table top Delegate unit with Plug-and- play functionality, built-in Loudspeaker and headphone socket with level control, GSM immunity. Color-coded light-ring indicator in head of microphone, priority Length of microphone from mounting surface 480 mm (18.9 in), Red indicates microphone is active, white indicates possible to speak, green indicates request to speak and flash green indicates next in line to speak. Approved Make Bosch, Shure

51

2598127

50943.67

... More
OD238709/2023-2024:Supply and Installation of conference Extension Cable 10 Mtr from OEM. Approved Make Bosch

1

12222

12222.48

... More
OD238736/2023-2024:Supply and Installation of Wireless Handheld Microphone , Type : dynamic; Frequency response : 50 to 16,000 Hz (–3 dB) ; THD( total harmonic distortion) : ≤ 0.9% ; Pick-up pattern: cardioid ; Signal-to-noise ratio : ≥ 103 dBA ;RF output power : 10 mW ; Switching bandwidth up to 24 MHz ; Operating time approx. : 10 hrs ; Modulation wideband : FM ; Frequency : 8 frequency banks, each with up to 12 factory-preset channels ; Input sensitivity : 1.5 mV / Pa ; Receiver Principle : double superheterodyne ; Diversity principle : True Diversity or Better. Approved Make Sennheiser, Shure

1

58458

58458.44

... More
OD238744/2023-2024:Supply and Installation of wireless digital head worn Microphone System having Condenser type Microphone with cardioid pick up pattern, max SPL 150dB, with 56 MHz of tuning bandwidth and equidistant spacing enables up to 90 channels, 56 MHz of tuning bandwidth and equidistant spacing enables up to 90 channels, 2,240 selectable frequencies allow for fine tuning, up to 8 hours of operation with 2x AA batteries, Remote App, Transmission power BLE: max. 10 mW EIRP, Audio output level 18 dBu max, System Latency1.9 ms, THD≤ -60 dB for 1 kHz @ -3 dBfs input level. Approved Make Shure, Sennheiser

1

63685

63685.19

... More
OD238752/2023-2024:Supply and Installation of 15inch Gooseneck cardioid pre polarized condenser microphone, RF shielding against intermodulation from wireless devices, Frequency Response 50-20KHz, 130 dB SPL, Equivalent noise level 26 dB (A), Complete with Microphone base having Bi-colored light ring, 3pin XLRM connector, TTL logic output Microphone modes Toggle on/off, Push to mute, Push to talk, permanent on, Current consumption 3 mA, P12-P48V phantom power. Approved Make Shure, Sennheiser

1

37202

37202.99

... More
OD238758/2023-2024:Supply and Installation of 2 core audio cable with 2-10 AWG highly flexible stranded bare copper conductors with PVC insulation, PVC jacket with ripcord. Approved Make Belden

100

12660

126.6

... More
OD238767/2023-2024:Supply and installation of 2 core shielded microphone cable having Polyethylene Insulation, Bare copper braid Shield, Bare Copper Conductor. Approved Make Belden

50

5180

103.61

... More
OD238790/2023-2024:Supply and installation of XLR Connectors, 1/4 jack for connecting the Microphone to the Mixer. Approved Make Neutric

20

6021

301.06

... More
OD238805/2023-2024:Supply and Providing of 19 inch17U Floor mounting Industrial Grade Powder coated weather proof network rack with one sliding tray ,front glass door and cooling fan with PDU, Double side open with lock, Rolling wheels locks, Approved Make D-Link, Netrack, President, Rittal, Wallrack

1

21990

21990.89

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

100

9095

90.95

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

200

20230

101.15

... More
OD238985/2023-2024:Supply and installation of necessary electrical accessories for giving proper electrical power to the Rack. Approved Make: Legrand

1

1742

1742.25

... More
OD240711/2023-2024:Power line Surge protection device - OPTION 1( Class B+C) type SPD :This panel should include pluggable type surge arrester in suitable enclosure Class C/ Class 2 as per IEC 61643 (IP 20) , thermal dis connector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number arrester Spark Gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E). Nominal discharge current-20 kA (8/20µ sec) for Line to Neutral & 40 kA(8/20µ sec) for Neutral to Earth, max discharge current 40 kA (8/20µ sec)for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth voltage protection level 1400V (L to N) & 1200V (N to E).Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E)DIN rail mounting type etc complete with back up fuse as required and as directed. Approved Make Raycap ,obo,L&T

2

17256

8628.11

... More
PART-9-ELECTRONIC EQUIPMENTS(Electronics Work)

-

-

-

... More
OD253107/2023-2024:Supply and Installation of Laptop with following specification. Processor: Intel Core i5 1135 G7 @ 4.20 Ghz, 4 Core, 8 MB Cache TDP-Down 12W Memory: 8 GB DDR4 RAM Expandable up to at least 32GB Hard Disk: 256 GB SSD Display: Antiglare Full HD LED Backlit Display Display Size: 14” Wireless connectivity: Integrated wireless b/g/n, Integrated Bluetooth Speaker: Integrated Stereo Speaker Keyboard: Keyboard with Touch Pad Camera: Integrated HD Camera Audio: Integrated Expansion Port: 3 USB Port (at least two number of USB 3.0 and One number of Type C) ,10/100/1000 Ethernet Card, HDMI, 1Head phone/microphone e combo or Separate & other Standard features Power Supply: 230V, 50Hz AC Supply with rechargeable Battery Pack comprising of Li-Polymer battery/ Li- Ion Polymer battery Mouse: Optical Scroll mouse Carry case: Backpack Weight: Less than or equal to 1.7Kg (Weight without Charger) Certification: ROHS Compliance & BIS for Product Operating System: Windows 11 Home Approved Make Acer Dell HP

53

2834014

53471.98

... More
OD253109/2023-2024:Supply ,Installation .Testing of short throw projector having 3.500 lumen ,Resolution WXGA, 1280 x 800, 16:10,Aspect Ratio16:10,Lamp250 W, 5.000 h durability, 10.000 h durability (economy mode), 9.000 h durability (economy mode),ZoomDigital, Factor: 1 - 1,35,Lens-Optical,Image Size60 inches - 100 inches, Projection Distance Wide0,4 m ( 60 inch screen),Focal Distance3,7 mm, interfaces-USB 2.0 Type A, USB 2.0 Type B, RS-232C, Ethernet interface (100 Base-TX / 10 Base-T), Wireless LAN IEEE 802.11b/g/n (WiFi 4) (optional), VGA in (2x), VGA out, HDMI in (3x), Composite in, RGB in (2x), RGB out, MHL, Stereo mini jack audio out, Stereo mini jack audio in (3x), Microphone input, Sync. in, Sync. out. Approved Make Epson , Panasonic

2

233369

116684.57

... More
OD253113/2023-2024:Supply and Installation of Motorized Projector Screen having screen display size 150 Inches, aspect ratio 16:9,Mounting Type- ‎Ceiling Mount, Wall mount, Viewing Angle160 Degrees, Synchronous motor with RF Remote. Approved Make Vuemax,Liberty

2

68528

34264.25

... More
OD253114/2023-2024:Supply, installation, testing and commissioning of Premium High speed 15 Mtr HDMI cable with Ethernet, Max Data rate: 18Gbps resolution: 4K @ 60Hz (4:4:4), Multi - ChannelAudio support, High quality 24K gold-plated, corrosion-resistant and K-Lock Pull- Resistant connectors. Approved Make : Extron,Karmer

2

14867

7433.6

... More
OD256425/2023-2024:Supply and installation of Interactive touch screen having 85 inch panel dimension, Operating system -windows, Resolution 3,840 x 2,160,Pixel Pitch (HxV) 0.4875(H) mm x 0.4875(W) mm, Touch Technology Type Infrared touch technology, Response Time < 10 ms, Brightness (Typical) 350 .HDMI In minimum 2, Viewing Angle (H/V) 178/178, Bluetooth. Approved Make Acer, Samsung

1

279829

279829.13

... More
OD256993/2023-2024:Supply and Installation of Wall plate with Pass-Through Connectors for HDMI and PC Audio having HDMI female to HDMI female connector on 15 cm pigtail, 3.5 mm stereo mini jack, HDCP compliant, Max. video data rate 10.2 Gbps, Connector type 2 female HDMI to 2 female HDMI on a pigtail cable, 1 female 3.5mm stereo audio jack to captive screw connector, 1 female VGA to captive screw connector, Enclosure type Metal wall plate. Approved Make Extron , Kramer

1

10361

10361.13

... More
OD257713/2023-2024:Supply and Installation of active HDMI Splitter (1X4) that distribute one HDMI source to four HDMI displays simultaneously, Compliant with HDMI 1.4 protocol and supports the HDMI 1.4a version, With a frequency bandwidth of 2.97Gbps, EIDI duration of 4 seconds. Approved Make Black i, Kramer

1

6109

6109.77

... More
OD257715/2023-2024:Supply and Installation of High Speed HDMI 2.0 Cablesupport 4K @60Hz/30Hz with 5 meter length having 24K gold plated connector highpurity oxygen free copper conductor,Transfer digital audio and video signals at high speed of 10.2 GBPS. Approved Make : Extron,Kramer

1

4057

4057.12

... More
OD260847/2023-2024:Supply, Installation, Testing and Commissioning of 43 INCH 4K UHD LED TV having Resolution 3,840 x 2,160, input:: HDMI, and USB ports, Power supply 100v-240v, 50/60Hz, sound output minimum 20 watts, connecting cables as required. Additional swivel type Wall mounting Kit. Approved: Samsung/SONY/Panasonic

2

81305

40652.5

... More
OD260848/2023-2024:Supply and installation of Water Purifier with accessories including the following features. RO Purification, In-Tank UV with BioCote protection.Standard Filtration Supplied- Reverse Osmosis, Sediment Filter, Pre & Post Carbon Filter, UV Sensor and Leak Detection. Capacity- Header Tank 11 Litres, Cold tank 4 Litres & Hot Tank 1.5 Litres, Compressor-230V/50Hz , Water Temperatures- Cold 3°C-12°C and Hot 87°C Approved make :- Aquaguard Hot& Cold (RO+UV)

16

650440

40652.5

... More
OD260850/2023-2024:Supply and Installation of NAS(network-attached storage servers)server having 2U Rackmount Redundant power, 64-bit 4-core 2.2 GHz CPU, Optional Dual M.2 NVMe Slots for Cache, system memory of 4GB and minimum 16 nos of hot swapable HDD slot and minimum Data Transfer Rate ‎10 Gigabits Per Second,1 x Gen3 x8 slot (x4 link) / Optional 10GbE Support / 4 x RJ-45 1GbE LAN Port / 2 x USB 3.2 Gen 1 Port & 1 x eSATA Port / RAID 0, 1, 5, 6 & 10 , includes 16 nos of 16TB HDD Approved make: NAS, Synology Approved Make : Hard Disk: WD,Seagate

2

882740

441370



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.