Public Works Department Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Public Works Department - PWD Tender

Works
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Mar 2025
Closing Date17 Mar 2025
Tender Amount₹ 17,19,40,333 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)

217.54

1196

260219.17

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

217.54

414

90248.64

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

404.66

106

43047.52

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

71.41

190

13624.31

... More
OD74370/2024-2025:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M- 30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).<br> 800 mm dia.Excess or less cement used as per design mix is not payable or recoverable separately.

370

5888

2178700.6

... More
OD74371/2024-2025:Vertical load testing (INITIAL) of pipes in accordance with IS : 2911 (Part - IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification for 200 MT capacity pile

2

79000

158000

... More
OD74372/2024-2025: Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. For 200 tonne capacity Routine test

2

46675

93351.38

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

116.99

6814

797245.55

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

749.62

335

251354.75

... More
OD74373/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability ,as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum. Excess/less cement as per mix design is not recoverable or payable separately, All work up to plinth level

464.53

9506

4415904.93

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

959.47

258

248081.34

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

5747.73

649

3734876.9

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

329.67

717

236437.17

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

2626

863

2267839.86

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

357.49

732

261877.19

... More
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

1119.94

902

1010798.24

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

5748.48

815

4689320.93

... More
OD74374/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 360 kg/cum . All work above plinth level to all floor level

1754.09

11322

19860726.44

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

121071.6

98

11901338.28

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

309341.33

98

30408252.74

... More
50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

1.51

5950

8985

... More
OD74375/2024-2025:Providing and laying autoclaved aerated cement blocks masonry with 100 mm/150mm/200mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor all level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

343.73

7551

2595724.54

... More
50.6.1.9:Solid block masonry using pre cast solid blocks( Factory made) of size 40x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

6.87

7963

54700.73

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

11107.02

314

3488825.42

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

5841.35

267

1563086.58

... More
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

1491.21

412

614585.23

... More
OD188246/2024-2025:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), Excluding grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm

4009.79

2022

8108356.75

... More
OD188248/2024-2025:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x1200 mm

4827.5

161

780413

... More
OD188249/2024-2025:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), EXcluding grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x1200 mm

817.71

2067

1690419.08

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1037.78

1212

1258554.89

... More
8.12:Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge. a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

514.89

2915

1500914.65

... More
8.3.2:Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

633.6

442

280589.76

... More
11.20.1:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement

262.05

1437

376825.28

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

19857.7

70

1403145.22

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

19857.7

151

3007051.81

... More
13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

5800.93

189

1100436.61

... More
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

4.39

109862

482515.88

... More
50.9.2.1:Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood

125.44

3292

412962.28

... More
50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood

105.8

2744

290384.37

... More
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

378

210

79739.1

... More
9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

265

800

212063.6

... More
9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

76.06

4078

310203.25

... More
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

10963.89

194

2133463.36

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

192.76

143

27574.03

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

2981.71

677

2019718.87

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

24.49

3465

84855.99

... More
10.9:Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

7.7

787

6063.29

... More
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

396.9

1525

605661.46

... More
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

65.6

643

42188.67

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

1641.13

537

881433.97

... More
21.2.1:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

8.4

1174

9865.04

... More
21.18:Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

16.2

6587

106723.33

... More
14.34:Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete

8

273

2189.6

... More
OD186804/2024-2025:Steel work in built up Galvanized Pipe tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

3619.23

137

498730.03

... More
OD186805/2024-2025:Steel work for purlin/single section with Galvanized Pipe (GP) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

1889.01

100

189392.54

... More
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

413.27

738

305286.68

... More
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

863.15

548

473029.9

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

196.69

439

86454

... More
50.12.2.5:Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

8.75

917

8030.14

... More
12.59.1:Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.

243

1498

364128.21

... More
5.28:Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints.

40

6

262.4

... More
5.29.2.1:Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick150 mm wide

82.3

580

47796.55

... More
OD74379/2024-2025:DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site

46.92

1470

69001.49

... More
OD74380/2024-2025:Supplying and fixing Inauguration black granite stone including engraving letters,all kind of labour charges etc. complete

2

7711

15423.14

... More
OD74381/2024-2025:Supplying and fixing in position of stainless steel (Grade 304) letter/Symbols of gauge 22 (.8 mm thickness) in Malayalam of size 30cm or more as per design given by Dept. Officers at site

30

2680

80405.1

... More
OD74382/2024-2025:Extra conveyance of excavated soil by mechanical means including loading unloading etc complete up to near by dumping yard available as per the direction of Engineer In Charge

3000

39

119160

... More
10.5.2:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece

18

5035

90643.68

... More
OD74383/2024-2025:Providing and fixing PVC perforated pipes. This includes jointing of pipes with one step PVC solvent cement and testing of joints etc... complete as per the direction of Engineer-in-charge. 150mm dia 6kgf/cm2

95.46

758

72414.05

... More
OD74384/2024-2025:Supplying, filling, spreading and levelling stone boulders of size range 5cm to 20cm in filter media in the required thickness for all leads and lifts etc... all complete as per the direction of Engineer-in-charge.

80.12

1561

125110.5

... More
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

45

1011

45519.3

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

8710.27

291

2537300.49

... More
16.90:Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

5.4

2276

12291.59

... More
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

78.4

7823

613345.2

... More
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

70.24

6984

490578.83

... More
50.6.2.3:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

382.35

7977

3050303.19

... More
9.147D.3:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).

729.68

8136

5936832.81

... More
13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1167.56

135

158227.87

... More
OD188100/2024-2025:Random rubble masonry with hard stone in foundation and up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

22.29

5135

114476.08

... More
Toilet Block(Civil work)

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

17.14

296

5090.53

... More
OD74366/2024-2025:Dry rubble masonry (Departmental rubble) with hard stone in foundation and plinth including cost of bond stone and through stone.

17.14

1470

25207.9

... More
OD188208/2024-2025:Random rubble masonry with hard stone in foundation and up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

7.64

5135

39244.1

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

2.39

7990

19106.12

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

18.72

649

12166.86

... More
OD74367/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability ,as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum. Excess/less cement as per mix design is not recoverable or payable separately, All work up to plinth level

1.7

9245

15717.67

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

170

98

16711

... More
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

15.58

6644

103502.1

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

159.12

314

49981.18

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

42.76

267

11442.42

... More
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

29.92

412

12331.23

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

164.44

70

11619.4

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

35.11

815

28638.54

... More
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

16.68

902

15054.53

... More
OD74368/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 340 kg/cum . Excess/less cement as per mix design is not recoverable or payable separately. All work above plinth level upto floor V level

5.59

11370

63605.29

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

618.04

98

60753.33

... More
9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

35

800

28008.4

... More
9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

10.05

4078

40970.24

... More
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

0.23

109862

25158.5

... More
50.9.6.1:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters

3.19

3811

12143.22

... More
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

93.06

194

18108.55

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

4.5

143

643.73

... More
OD186371/2024-2025:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand),excluding grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

26.37

2825

74510.81

... More
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

4.77

1819

8679.44

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

37.44

1212

45404.99

... More
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

8000

10

82960

... More
Plumping and Sanitary(Civil work)

-

-

-

... More
17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

12

6381

76579.44

... More
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

48

7868

377706.24

... More
17.7.2:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap

54

3238

174879.54

... More
17.4.1:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern

54

5864

316686.78

... More
8.10.2:Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

32.4

3786

122685.19

... More
50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

53

67

3553.12

... More
50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

53

128

6797.25

... More
50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.

60

758

45487.8

... More
18.50.1:Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore

61

728

44431.79

... More
18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

170

626

106455.7

... More
17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap.

83

52

4355.01

... More
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

118.6

526

62404.95

... More
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

95.5

722

69036.95

... More
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

250

381

95432.5

... More
50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow

60

132

7921.2

... More
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

154

161

24803.24

... More
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow

46

107

4950.98

... More
50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer

16

107

1722.08

... More
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

69

174

12061.89

... More
50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap

8

75

600.88

... More
50.18.9.7.1:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2

146.3

346

50760.25

... More
50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow

62

105

6529.22

... More
50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2

147.2

609

89716.93

... More
50.18.9.17.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall

400

225

90248

... More
50.18.9.6.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2

138.65

243

33794.55

... More
50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

130.5

375

48985.79

... More
50.18.9.16.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

90.95

385

35028.48

... More
50.18.8.4.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2

659

426

281333.69

... More
50.18.9.14.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall

165.95

309

51411.31

... More
50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall

129.6

317

41135.04

... More
50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

200.85

420

84531.74

... More
50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall

68.65

275

18939.85

... More
50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall

116.75

266

31069.51

... More
50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl

16

76

1222.4

... More
50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

16

86

1389.76

... More
50.18.9.20.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap

6

60

360.84

... More
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend

302

79

23951.62

... More
50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow

67

72

4885.64

... More
50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow

54

80

4345.38

... More
50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee

94

86

8093.4

... More
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

5

123

619.45

... More
50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow

5

64

321.05

... More
19.7.1.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

12836

51345.4

... More
SEPTIC TANK(Civil work)

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

153.57

296

45606.62

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

64

106

6808.32

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

8.31

6814

56604.39

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

219.08

717

157124.18

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

5.52

649

3586.9

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

75.68

815

61735.96

... More
OD74364/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability ,as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum. Excess/less cement as per mix design is not recoverable or payable separately, All work up to plinth level

30.22

9506

287317.2

... More
OD74365/2024-2025:Dry rubble masonry (Departmental rubble) with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 Coarse Sand:12 graded stone aggregate 20mm nominal size) including cost of bond stone and through stone.

20.93

1470

30780.08

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3404.88

98

334699.7

... More
Fire fighting Water Tank(Civil work)

-

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

191.84

214

41060.37

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

111.91

106

11904.88

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

5.33

6814

36316.5

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

8.52

335

2856.84

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

129.72

717

93035.18

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

40.55

815

33078.66

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

4.13

649

2680.42

... More
OD74385/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability ,as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum. Excess/less cement as per mix design is not recoverable or payable separately, All work up to plinth level

46.78

9248

432673.98

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

69.6

401

27924.91

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

12913.2

98

1269367.56

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

72

570

41058.72

... More
OD74386/2024-2025:Supplying and fixing C.I with frame for manholes: 24 x 24 inches rectangular C.I cover the weight of the cover to be no less than 100 kg

2

8003

16007.3

... More
Rain water harvesting(Civil work)

-

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

94.12

214

20143.65

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

42.5

106

4521.58

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

3.13

6814

21316.94

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

6.6

335

2213.05

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

104

717

74588.8

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

34.4

815

28061.8

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

4.5

649

2924.1

... More
OD74362/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability ,as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum. Excess/less cement as per mix design is not recoverable or payable separately, All work up to plinth level

30.39

9248

281062.83

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

9117

98

896201.1

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

55

401

22067.1

... More
OD74363/2024-2025:Supplying and fixing C.I with frame for manholes: 24 x 24 inches rectangular C.I cover the weight of the cover to be no less than 100 kg

2

8003

16007.3

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

49

570

27942.74

... More
Compound wall and gate (Civil work)

-

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

76.83

214

16443.71

... More
OD189236/2024-2025:Dry Rubble masonry with hard stone in foundation and plinth including cost of through stone and bond stone.

176.5

3491

616254.93

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

65.18

6814

444166.62

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

26.56

335

8905.83

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

40

863

34544.4

... More
5.9.21:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.

64.42

755

48649.76

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

18.78

9085

170609.66

... More
OD188936/2024-2025:Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve work ability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 340 kg/ cum. "for excess/less cement used as per mix design is not payable or recoverable". All work up to plinth level

6.97

9464

65946.06

... More
OD188974/2024-2025: Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 340 kg/cum . "for excess/less cement used as per mix design is not payable or recoverable". All work above plinth level upto floor V level

9.18

11147

102336.25

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1027.6

98

101013.08

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

3819.6

98

375466.68

... More
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

45.2

338

15295.23

... More
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

18.36

6237

114535.18

... More
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

318.9

299

95435.71

... More
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

18.2

267

4870.14

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

72

291

20973.6

... More
13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

330.1

189

62619.02

... More
OD189012/2024-2025:Steel work in built up Galvanized Pipe tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete

1209.29

137

166640.02

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

39

143

5578.95

... More
12.48:Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

53.46

381

20411.56

... More
12.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).

16.24

84

1380.24

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

64.02

7990

511574.22

... More
Electrification(Electrical work)

-

-

-

... More
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

610

1176

717762.6

... More
1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

275

660

181524.75

... More
OD233525/2024-2025:Supply and fixing Conveyance, installation, testing and commissioning of 1200 lumen round/ square type LED light fitting in surface mount fitting made of diecast aluminum, having efficiency not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree / Osram or equivalent make and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections etc. as required

168

1522

255780

... More
OD253738/2024-2025:Supply and fixing DC Digital Ammeter/votmeter with shunt trip accuracy class 1 and giving necessary connections etc..

2

517

1034.74

... More
OD253739/2024-2025:SITC of 300/5 A, 5 VA, accuracy class 1, Tape wound Metering CT

4

836

3345.2

... More
OD253746/2024-2025:Supply and fixing Flush head Actuator - Green with legend 'satart, (Contact - 1 NC)

1

292

292.26

... More
OD253747/2024-2025:Supply and fixing Flush head Actuator - Red with legend 'stop', (Contact - 1 NC)

1

251

251.9

... More
OD257554/2024-2025:Supply and laying PVC pipe 50/63 mm outer dia.6kgf/cm2 in roof beam for fire fighting pipe line work ,with covered two end by masking tape, tying & fixing the conduit firmly with the re-inforcement etc. as required

30

117

3534.3

... More
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

76

476

36231.48

... More
OD249177/2024-2025:Supply and fixing Conveyance, installation, testing and commissioning of 1800 lumen round/ square surface mount fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/NicheaS directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required

29

2140

62078.56

... More
OD249178/2024-2025:Supply Conveyance, installation, testing and commissioning of 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) suspended from ceiling using 4 nos steel chain (16 SWG or nearest) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (for fitting in false ceiling)

20

5217

104345.2

... More
OD249180/2024-2025: Supply and fixing 9W white tube light Batten type mirror light fittings fixed directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required PHILIPS or equivalent make

12

446

5354.28

... More
OD249182/2024-2025:Supply of 7W /9W LED Bulb suitable for B 22 type holder and 230/240 volt AC 50 Hz power supply( Philips or its Equivalent standard)

8

117

938.48

... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

9

175

1576.62

... More
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.

18

189

3417.3

... More
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

187

406

76000.54

... More
OD250471/2024-2025:Supply Conveyance, installation, testing and commissioning of 7W LED bulk head fittings suitable for surface and wall mounting output greater than 100lumen/W 6500 K with IP 65 protection and IK08 protection poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required Philips vistaglow or its equivalent

21

947

19899.39

... More
OD250472/2024-2025:Supply Conveyance, installation, testing and commissioning of 6W LED bulk head fittings suitable for surface and wall mounting output greater than 115 lumen/W 6500 K with IP 66 protection and IK09 protection with power factor greater than 0.95 at full load, internal surge protection up to 4 KV,and corrosion proof LM6 grade pressure die cast aluminum body & poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required Philips endura or its equivalent

56

1414

79212.56

... More
90.3.23.3:Supply & installation of fittings suspended on steel chain <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet .5mm thick with all accessories and lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200mm 1X20W LED Lamp with box type fixture

125

1227

153457.5

... More
90.3.23.4:Supply & installation of fittings suspended on steel chain <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet .5mm thick with all accessories and lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200mm 2X20W LED Lamp with box type fixture

125

1798

224756.25

... More
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

81

1251

101394.99

... More
OD264283/2024-2025:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

93

3139

291956.76

... More
OD264307/2024-2025:Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

98

3559

348858.44

... More
90.3.8:Supplying and providing extra steel chain (16 SWG) 4 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.

40

98

3920

... More
90.3.7:Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.

125

72

9086.25

... More
1.51:Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes

4

199

797.44

... More
1.57:Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. lCD

1

760

760.21

... More
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

800

44

35376

... More
90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm

200

64

12998

... More
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm

40

133

5348

... More
OD249185/2024-2025:Supply Conveyance, installation , testing and commissioning of exhaust fans (in and out type) of size 225 mm sweep 1350/1400 RPM Exhaust fan in metal frame with metal guard , bird guard including anti corrosive powder coated , working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan as required .

41

2504

102702.13

... More
OD243331/2024-2025:Supply, conveyance, installation, testing and commissioning of 300/305 mm, single phase, Heavy duty exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

2

2870

5740.48

... More
OD257028/2024-2025:Supply Conveyance, installation , testing and commissioning of exhaust fans of size 380 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.

2

3382

6765.76

... More
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell

13

191

2488.85

... More
1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep

12

196

2353.68

... More
1.22.6:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 125 mm X 60 mm deep

20

283

5676.4

... More
90.15.3.5:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters

5

23722

118611.6

... More
90.15.3.6:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters

6

24329

145975.92

... More
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

3

4619

13859.7

... More
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

9

7509

67588.2

... More
11.3.1:Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre

15

5337

80067.75

... More
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm

100

82

8293

... More
OD257118/2024-2025:SITC of 25A single pole power contactor for control application and giving connections etc as required.

3

1088

3266.22

... More
OD253755/2024-2025:Supply, Conveyance, installation, testing, and commissioning of 32W integrated surface type LED fitting with CRCA powder coated body and polycarbonate covering complete with all accessories with nominal system level lumen package of 3200 Lumen , Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC s. Fittings fixed directly on wall or ceiling and giving connection with existing length of 16/0.20mm 3 core copper conductor flex wire and giving connections as required.(Model Cirrus mini pro SM 365C LED 32- 6500 PSU OD WH Make -Philips/ its Equivalent-)

2

4944

9888.32

... More
OD253756/2024-2025:Providing and fixing digital timer switch suitable for switching purpose 110 - 240 VAC 1 Phase - 2W 2 C/O , Base/Din 50 ON/OFF Each

1

4344

4344.31

... More
OD243612/2024-2025:Supply and providing 4pole power contactor with necessary NO/NC contacts suitable for light switching arrangements

1

1495

1495.06

... More
OD253784/2024-2025:Supply, and fixing of LED Aviation light operating input voltage range 100 – 270VAC Die-cast aluminum housing with Red polycarbonate doom, Integral drive, Supper flux 5mm 302nos LEDs incorporated, Ingress protection : IP65 protection against short-circuit, protection against surge life time 50,000Hrs etc fitted on minimum 1 mt height 32 mm 'B' class GI pipe in single section as post top types and pipe fitted on highest point of the terrace floor with suitable clamp and pole painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required. Bajaj BGAV 302 LED Aviation Light Luminaires or its equivalent make

1

6529

6529.33

... More
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)

500

25

12890

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1500

99

148920

... More
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

750

107

80610

... More
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

65

109

7121.4

... More
OD235862/2024-2025:Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cm on surface including making good the damages, colour washing etc. as required. 20 mm dia

100

53

5323

... More
90.1.1.1:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm

1750

52

92277.5

... More
90.1.1.2:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm

1000

58

58500

... More
90.1.1.3:Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.32 mm

100

54

5494

... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

700

64

44954

... More
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm

300

118

35658

... More
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm

100

192

19263

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

1200

89

107124

... More
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm

700

168

118272

... More
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

175

138

24309.25

... More
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm

200

65

13176

... More
1.17.18:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 2.5 sq. mm

150

267

40168.5

... More
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm

1000

49

49180

... More
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm

150

102

15325.5

... More
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm

150

185

27780

... More
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm

45

261

11770.65

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

445

101

45145.25

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

42

156

6575.94

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

608

131

80219.52

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

42

207

8725.92

... More
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator

7

264

1848.56

... More
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator

4

128

512.72

... More
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket

7

316

2216.27

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

2

288

577.56

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

44

317

13987.6

... More
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

7

340

2385.25

... More
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface

1

245

245.25

... More
90.10.1.4:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )4 module moulded plastic box on surface

16

256

4100.64

... More
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

1

135

135.54

... More
1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module

16

163

2622.24

... More
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

9

395

3562.83

... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

10

455

4550.8

... More
OD249697/2024-2025:Supplying and fixing DP sheet steel enclosure on surface/ recess etc. as required.

21

424

8909.25

... More
OD243390/2024-2025:Supply and installation of sheet steel, phosphatized and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required. - FP enclosure for independent mounting of MCB/RCCB/Isolator.

9

687

6187.23

... More
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

3

1974

5922.45

... More
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

10

2092

20922.6

... More
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

9

2440

21962.79

... More
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

2915

2915.93

... More
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

15

2848

42724.65

... More
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

1

4515

4515.94

... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

10

6555

65558.7

... More
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

10

7656

76567

... More
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

7246

7246.62

... More
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

9136

9136.89

... More
90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

3819

3819.54

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

260

237

61648.6

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

41

982

40262.82

... More
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

50

9

489

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

40

402

16098.8

... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

32

989

31654.4

... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

6

997

5982.42

... More
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

18

2290

41237.46

... More
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

2490

2490.98

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

6

3121

18729.48

... More
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

16

3003

48055.52

... More
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

350

289

101367

... More
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm

360

199

71928

... More
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

300

219

65925

... More
90.12.10.6:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation110/94 mm or nearest size

30

427

12822.6

... More
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm

18

25

452.16

... More
90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm

176

25

4542.56

... More
90.12.5.34:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm

30

1121

33647.1

... More
OD253871/2024-2025:Supply and clamping of 1 no1.5 sqmm 4core PVC/ XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE with the cables, of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (clamped with 1mm thick saddle)

15

170

2558.1

... More
90.12.7.13:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp

30

208

6247.8

... More
90.12.7.19:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 70 sq mm

30

504

15126.3

... More
90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm

15

1791

26867.55

... More
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

45

378

17052.75

... More
90.12.1.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm

20

384

7696.6

... More
90.12.7.34:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

25

1242

31052.25

... More
90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

30

580

17412.3

... More
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

200

244

48962

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

115

276

31780.25

... More
90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm

15

245

3685.65

... More
90.12.7.35:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm

15

1530

22953

... More
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

6

356

2141.82

... More
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

437

1749.16

... More
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

46

260

11981.62

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

8

296

2373.44

... More
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

4

235

941.04

... More
9.1.12:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)

4

402

1610.52

... More
9.1.27:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

6

834

5005.98

... More
9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

2

1113

2226.18

... More
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

4

251

1004.08

... More
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

2

961

1923.78

... More
OD253937/2024-2025:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor control cable of 650V grade as required.2 X 1.5/2.5 sq. mm .

6

260

1565.16

... More
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size

15

143

2154.6

... More
90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL)

2

4054

8109.78

... More
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor

1

1628

1628.57

... More
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

4

3408

13634.28

... More
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

80

2533

202715.2

... More
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

150

46

7027.5

... More
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

22

1034

22768.9

... More
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

20

165

3313.4

... More
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

15000

6

99000

... More
90.14.7:Supply and providing copper earth bus in the panel board

2000

6

12560

... More
OD263950/2024-2025:Supply and providing plate earthing with 1200x1200x12mm GI earth plate,50 mm GI(medium class) watering pipe,GI funnel with weld mesh,25x5 mm GI clamps,CI/MS cover plate with locking arrangements,charcoal/coke and salt etc including providing brick work masonry enclosure at the top (450x450x450mm inside)etc as required.

6

13137

78825.96

... More
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

10

1199

11991.9

... More
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

100

1014

101420

... More
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

1

4794

4794.22

... More
5.10:Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

20

1454

29096.2

... More
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

200

245

49086

... More
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.

1.5

8974

13462.34

... More
15.4.1:Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required1 output per phase and suitable for single phase supply

1

4347

4347.88

... More
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

4

6117

24470.08

... More
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

180

155

27936

... More
1.21.5:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm

8

187

1500.48

... More
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)

300

44

13392

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

300

63

19053

... More
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

100

98

9809

... More
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

170

1087

184953.2

... More
90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover

70

112

7865.2

... More
90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer

30

64

1948.8

... More
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

20

251

5030.8

... More
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

30

142

4265.4

... More
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface

5

251

1256.4

... More
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface

70

334

23407.3

... More
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

11

152

1672.66

... More
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

170

233

39638.9

... More
90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box

6

177

1063.86

... More
90.9.2.14:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box

100

276

27674

... More
2.2.13:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA 4 Pole

3

8769

26309.61

... More
2.2.14:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA

4

8921

35686

... More
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

2

7712

15425

... More
90.14.10.2:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

8

4827

38620.16

... More
90.14.10.15:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

2

24133

48266.66

... More
90.14.11.11:MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630A MCCB.

1

1367

1367.95

... More
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

15

1922

28844.1

... More
OD237493/2024-2025:Supply and foxing 100/5A,5VA, accuracy class 1, tape wound metering CT etc. as required.

4

1226

4904.32

... More
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.

2

1367

2735.9

... More
90.14.11.15:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A

3

2218

6655.62

... More
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N

23

2466

56730.88

... More
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N

4

3475

13901.76

... More
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N

3

7162

21486.69

... More
2.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N

2

7961

15922.26

... More
2.1.6:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N

1

10826

10826.28

... More
OD257427/2024-2025:Supply and proving of 8 Pin Pla Relay with base for control circuit Voltage: 24 Vdc/250 Vac

1

299

299.58

... More
2.2.18:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.400 Amp, 50 KA, 4 pole

1

31126

31126.35

... More
OD253656/2024-2025:Supply, laying and clamping of 1 no. 1.5 sqmm 2 core PVC / XLPE insulated armoured control cables with copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPEes, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

30

185

5558.7

... More
OD253622/2024-2025:Supply and fixing Multifunction meter to read:W, Wh, PF or VA, Vah, PF or VAR, VARh, PF ? 3 ph accuracy class 1

2

7105

14210.56

... More
OD253623/2024-2025:Supply and fixing Danger 415 V, 100 x 75 mm aluminium anodised legend

2

47

94.32

... More
OD253624/2024-2025:Supply and fixing Auto - Manual, 40 x 25 mm with 15 m hole aluminium

2

206

413.26

... More
OD253625/2024-2025:Supply and fixing Earth, 40 x 20 mm with 8 mm hole aluminium anodised legend plates

7

40

281.89

... More
OD253626/2024-2025:Supply and fixing Cable alley, 100 x 40 mm aluminium anodised legend plates.

14

39

550.06

... More
OD253627/2024-2025:Supply and fixing Bus bar chamber, 100 x 40 mm aluminium anodised legend plates

14

47

660.24

... More
OD253628/2024-2025:Supply and fixing Danger 415 V, 150 x 100 mm aluminium anodised legend

5

62

314.55

... More
OD253630/2024-2025:Supply and fixing LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia Blue colours

6

115

690.54

... More
OD253631/2024-2025:Supply and fixing LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia Red, Green, Black, Yellow, Orange colours

12

87

1050.24

... More
OD253633/2024-2025:Supply & fixing 6 A 3 pole selector switch to suitable for AUTO/MANUAL

2

110

221.4

... More
OD253585/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded 2.5 Sq.mm single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

50

33

1676.5

... More
OD253587/2024-2025:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded 1.5 Sq.mm single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

60

25

1515.6

... More
OD253865/2024-2025:Providing and fixing following 415 V , 50 Hz , Automatic Transfer switch (ATS) in cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 250Amp,

1

71561

71561.58

... More
OD253866/2024-2025:Supply and fixing Supply & fixing three phase Automatic changeover with current limiter(ACCL) 32A/32 A fixed and and giving connection etc as required.

15

6591

98865.9

... More
OD237746/2024-2025:Supply and providing 3 mm thick Elastomeric Fire retardant insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength with fixing with using suitable type synthetic adhesive as required

2

3067

6134.84

... More
OD251522/2024-2025:Supply and providing 2.00 mm thick, 3.3 kV, Synthetic elastomeric fire retardant insulating sheet and fixed on the floor with using suitable synthetic enamel paint as required

10

2005

20054.7

... More
90.14.11.9:MCCB AccessoriesSupply and fixing auxiliary switch (1 NO + 1 NC) in the existing MCCB of rating up to 630 A.

1

826

826.03

... More
OD237747/2024-2025:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

1

358

358.94

... More
OD237751/2024-2025:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.

5

499

2499.3

... More
OD237756/2024-2025:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required - 2.50 cm, 4 cm or 5 cm height

800

11

9296

... More
4.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

10

738

7384.4

... More
4.1.6:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness

20

831

16634

... More
OD253546/2024-2025:Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable trays made out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.

800

129

103480

... More
4.1.7:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

6

908

5453.34

... More
4.1.16:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.900 mm width X 75 mm depth X 2.0 mm thickness

10

1407

14075.1

... More
OD237759/2024-2025:Supply and fixing 2-20 A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc

24

141

3394.32

... More
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)

60

25

1501.2

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

90

26

2421

... More
OD243412/2024-2025:Supply and providing 25x6mm brass nut and bolt etc. as required.

50

20

1025

... More
OD243410/2024-2025:Supply and providing 25x3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.

60

18

1129.8

... More
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

30

27

827.7

... More
90.16.3.18:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm aluminium strip

220

131

28864

... More
90.16.4.15:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm aluminium strip

200

202

40578

... More
90.16.4.16:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 6 mm aluminium strip

1

255

255.89

... More
OD254010/2024-2025:Supply & Providing and fixing of fully solid 2mt Vertical Air terminal made up of Semi-hard (E-AlMgSiO5), 16mm rod tapered to 10mm. including fixing steel clamp , connector etc Cape-VAT 3

3

3332

9998.07

... More
OD243467/2024-2025:Supply, installation,testing and commissioning of 3 KVA UPS with tubular battery with backup of 2 hours with the following specifications . a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD : ≤ 10% f) Overall Efficiency : ≥87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. l) EN/IEC 620401 for General Safety compatibility m) EN/IEC 620402 for Electromagnetic Compatibility. n) EN/IEC 620403 for Performance o) EN/IEC 620404 for Environmental Compatibility p) battery : exide / panasonic or equivalent

1

147251

147251.67

... More
OD251519/2024-2025:Charges for copying CAD drawing of scheme , colour printing etc for additional sheets

150

17

2613

... More
OD251520/2024-2025:Charges for Preparetion of CAD drawing of Electrical scheme , colour printing etc for getting Scheme Approval from Electrical Inspectorate for first copy

30

811

24333

... More
OD253365/2024-2025:Supply, conveyance and fixing the following types switch dis-connector-SD MCCB with out protection release L&T make: DN2-250SD-CM96802OOPOOG conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly . 250A 4 pole switch dis-connector-SD MCCB with operating handle ,shaft and its complete accessories.

1

23757

23757.21

... More
OD253369/2024-2025:Supply and installation of Sintex box and GS-JB-2014 250x150x95 suitable for providing NCB/Isolator/Connector and connections as required

6

743

4458.48

... More
OD254262/2024-2025:Supply and providing of 70 sq.mm copper cable lug and giving connections etc. are required

8

472

3777.52

... More
OD254263/2024-2025:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade single core braided copper conductor cable conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.70 sq mm

2

2168

4336.96

... More
OD253416/2024-2025:Supply installation Testing and commissioning of Three Phase Surge Protection Device as per EN/IEC 61643-11 suitable for protecting Type 1+2/Class I+II Modular combined of lightning currents and protecting against voltage surges as TNS, TNC, TT and IT systems (3+1 configuration). Lightning impulse current upto 12.5KA and nominal discharge current 20/50KA with a response time (tA) less than 100 ns. suitable for mounting on Din rails. Easily replicable protection module having indication green to red make:Mersen model no:STPT-12K320V-4PG or equvalent

1

18264

18264.48

... More
OD253419/2024-2025:Supply and fixing following rating Surge Protection Devices (1P+N) ,Conforms to IEC 61643-11, Type 1+2PG(Protection against direct and indirect lightning surges) , Maximum Discharge Current - Imax up to 7 kA,-275V in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. ( MERSEN or its Equivalent Make)

2

6531

13062.02

... More
OD253968/2024-2025: Supply and providing 6mm MS chequered plate in position excluding frame work

15

2234

33522.15

... More
16.4.5:Supplying, laying/fixing , testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum duly covered with a layer of 120gm/sqm polythene sheet (vapour barrier ) on existing pipe and finally applying 0.63 mm aluminium sheet cladding complete with type 3 grade 1 roofing feltstrip (as per IS: 1322 as amended up to date at joints etc. as per specifications and as required.insulation of thickness 25mm on existing pipe

5

2141

10707.8

... More
OD264356/2024-2025:Supplying, installation, testing and commissioning of electric Horizontal type, submercible pump stainless steel body, 5HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 67 class of protection for enclosure, horizontal foot mounted type suction guard, eyebolts etc. as required. discharge range 5.5 lps to 2.2 lps at 30 to 50 m Head range

2

33702

67404.32

... More
OD265664/2024-2025:Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 18%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.

6

73047

438284.7

... More
OD265683/2024-2025:Supply and providing reverse power relay

1

24430

24430.12

... More
Providing LIFT(Electrical work)

-

-

-

... More
OD243392/2024-2025:Supply, Installation,Testing and Commissioning of 16 Passenger gearless lift with machine room with the following specification including all required standard features.1 .Type of Lift:16 Passenger capacity , Gearless 2. Load / Persons :1088 Kg. / 16persons 3 .Rated speed :1 M/Sec. 4. Travel : 25.9 Mtr ( Approx) 5. No. of floor and entrance served: 8stops and 8 openings 6. No. of floor served :Eight floors 7. Method of control : Micro processor based V3F with ARD system. 8. Size of lift well :2500 mm(W) X 3150 mm(D) 9. Car entrance: As per IS. 10.Leveling accuracy : As per IS 11. Car size: As per IS or as per barrier free guidelines12. Drive : Variable voltage variable frequency(V3F) 13 .Operation : Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel with back side mirror finish (SS304,make:Tata/Jindal) cabinet with Scratch proof Stainless steel door (sheet 1mm thickness), Stainless steel mat finish ceiling, Aluminium 3mm minimum thickness anti skid flooring, fan with timer cut-off, push to talk, LED display, LED light, hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance : Automatic centre/Telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and half framed glass door 16. Call and position indicators : Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply : 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infra red door opening system: To be provide for entire length of the door 19. Automatic Rescue Device :Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four successive rescue operation at full load . The rescue operation should act within 10 seconds of power failure 20. Regulation :350V 450V (SMPS based) 21. Indication in the car : a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Non stop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel :Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests :At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel (machine and rope ending point support should extended to existing well wall side using suitable I/C section channels as per the direction of department staff) f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit

1

2791607

2791607.18

... More
OD243400/2024-2025:Supply, Installation,Testing and Commissioning of 10passenger gearless lift with machine room with the following specification including all required standard features.1 .Type of Lift:10 Passenger capacity , Gearless 2. Load / Persons :680 Kg. / 10persons 3 .Rated speed :1 M/Sec. 4. Travel : 25.9 Mtr ( Approx) 5. No. of floor and entrance served: 8 stops and 8 openings 6. No. of floor served :Eight floors 7. Method of control : Micro processor based V3F with ARD system. 8. Size of lift well :1900 mm(W) X 3150 mm(D) 9. Car entrance: As per IS. 10.Leveling accuracy : As per IS 11. Car size: As per IS 12. Drive : Variable voltage variable frequency(V3F) 13 .Operation : Simplex full selective collective control with ON/OFF switch 14. Construction of design and furnishing of car body work: Vandal proof Stainless steel with back side mirror finish (SS304,make:Tata/Jindal) cabinet with Scratch proof Stainless steel door (sheet 1mm thickness), Stainless steel mat finish ceiling, Aluminium 3mm minimum thickness anti skid flooring, fan with timer cut-off, push to talk, LED display, LED light, hand rails and floor announcement system. All buttons in car and all landings should have Braille sign. 15. Landing entrance : Automatic centre/Telescopic opening Vandal proof stainless steel sliding door as per ISS with provision for mechanical opening key for emergency with full length infra red light curtains and half framed glass door 16. Call and position indicators : Up/down direction & position Dot Matrix LED indication shall be provided at all landings 17. Electric supply : 1) Light 230/50C/s single phase 2 wire system. 2) 415V 50C/s 3 phase 4 wire system. 18. Infra red door opening system: To be provide for entire length of the door 19. Automatic Rescue Device :Provide automatic rescue device with an electronic controller powered by maintenance free batteries with capacity for minimum four successive rescue operation at full load . The rescue operation should act within 10 seconds of power failure 20. Regulation :350V 450V (SMPS based) 21. Indication in the car : a) Car position b) Call indicator c) Door close/open push button d) Emergency stop button e) Flush mounted switch for fan and light f) Non stop button g) Battery operated emergency lamp with rechargeable batteries. h) Battery operated alarm bell i) Intercom wiring with one master unit with two slaves j) Fireman's switch at main lobby i) Auto attendant control (inside the car) 22. Winding handle Manual winding handle for use in emergency. 23. Safeties a) Over speed governor, operated safety gear b) Buffers c) Motor over load and under voltage protection d) Phase reversal protection e) Other safeties as per ISS f) Single phase preventer g) Final limit switch 24. Leveling Automatic leveling at all landing as per IS. 25. Control panel :Control panel will be dust and vermin proof of sheet metal enclosure 26. Announcement System: To provide lift announcement system 27. Tests :At site test as per IS to be carried out and approval from Electrical Inspectorate before Handing over. 28. Scope of work:- a) Supply of lift materials b)Minor civil works such as removal of temporary brick work in the lift entrance without affecting the building structure, finishing/ altering civil works in lift entrance/ pit by providing brick work & plastering if necessary including minor civil works such as construction of buffer block in the pit machine foundation in the machine room, necessary core cutting , cutting pockets and grounding brackets for the guide rails, grouting boxes for control units, correction of wall opening in the front side in plastering c) Scaffolding d) Door frames e) Supporting steel (machine and rope ending point support should extended to existing well wall side using suitable I/C section channels as per the direction of department staff) f) Temporary electric supply for installation of lift. Electric supply for testing and commissioning of lift is to be arranged by the firm on their own account. g) Intercom facilities with one master and two slaves h) Battery operated alarm i) Obtaining Scheme approval as well as energization Certificate from the electrical Inspectorate including preparation of necessary drawing for the same. inclusive of necessary fee to the Inspectorate and first year insurance as per new lift rule by the firm for which no refund will be made from the department including taking insurance for one year as per new lift rule. j) Supply of book let with complete details of maintenance schedule and control diagram. k) Giving training to department staff for attending trouble shooting 28. Guarantee: Company shall carry out free maintenance and service during warranty period which also includes a) Cleaning lift equipment b) Lubrication of all moving parts c) Replacing of lubricating oil when required d) Checking and adjusting contacts e) Replacing fusible item alarm etc. f) Recharging batteries in case of drain/ renewing batteries g ) Replacing /rewinding of all defective parts of the lift including motors and V3F unit

1

2506043

2506043.69

... More
FIRE FIGHTING SYSTEM(Electrical work)

-

-

-

... More
90.17.1.5:Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 70 m Head

2

324886

649773.42

... More
90.17.2.5:Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head

1

537952

537952.27

... More
90.17.3.2:Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) a. Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head

2

91244

182489.36

... More
90.17.7.1:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia

600

497

298596

... More
90.17.7.2:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :32 mm dia

180

549

98920.8

... More
90.17.7.3:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm dia

125

680

85026.25

... More
90.17.7.4:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia

75

799

59956.5

... More
90.17.7.5:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia

75

1014

76066.5

... More
90.17.7.6:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia

100

1118

111801

... More
90.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia

100

1460

146032

... More
90.17.7.8:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia

190

1979

376181

... More
90.17.7.9:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm)

15

2759

41398.5

... More
90.17.15.4:Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm dia

2

19678

39356.08

... More
OD240905/2024-2025:Supply, installation, testing, commissioning of Rubber Expansion bellows with required flanges ,nuts, bolts &amp; accessories 150 mm dia single Arch

4

12698

50795.44

... More
OD240906/2024-2025:Supply, installation, testing, commissioning of Rubber Expansion bellows with required flanges ,nuts, bolts &amp; accessories 100 mm dia single Arch

2

10028

20057.04

... More
OD240907/2024-2025:Supply, installation, testing, commissioning of Rubber Expansion bellows with required flanges ,nuts, bolts &amp; accessories 80 mm dia

2

4898

9796.32

... More
90.17.11.1:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required40 mm dia

15

3208

48127.65

... More
90.17.11.4:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia

10

4470

44707.3

... More
90.17.11.5:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia

26

6001

156041.6

... More
90.17.11.6:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia

4

8047

32190.92

... More
90.17.11.7:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required200 mm dia

3

13516

40548.84

... More
90.17.14.4:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia

2

6855

13710.7

... More
90.17.14.5:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia

4

9845

39382

... More
90.17.14.7:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia

4

15747

62989.72

... More
90.17.9.2:Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel

15

5493

82407.3

... More
90.17.10.2:Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as requiredSingle headed Stainless steel

2

5493

10987.64

... More
OD240940/2024-2025:Supply, installation, testing and commissioning of weather proof hose cabinet having the size of 750x500x250mm made of 16gauge MS Sheet with PCC supports and full front front glass door and locking arrangements ssuitable to accodmmodate 2 nos 15m long hose pipes and 1 No. branch pie. The cabiner shall be painted to scarlet red colour outside and off white inside etc, as required.

11

6388

70270.75

... More
OD251223/2024-2025:HOSE BOX:Supplying and fixing of weather proof hose cabinet fabricated from 1.5mm thick MS sheet with 6mm thick glazed front glass doors and locking arrangements suitable for accommodate, 2 Nos 15 Mtrs long hose pipe, 1 No. branch pipe, fittings etc.The cabinet shall be painted with one coat of primer and 2 coatts of synthetic enamel paint of post office red.

17

3955

67239.42

... More
90.17.16.2:Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)

27

3909

105567.03

... More
90.17.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b. 20 mm nominal internal dia gun metal globe valve & nozzle. c. Drum and brackets for fixing the equipmets on wall. d. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

15

7798

116974.65

... More
90.17.18.1:Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal

17

2128

36178.55

... More
90.17.20:Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

2

16168

32337.74

... More
OD240939/2024-2025:Supplying, fixing, testing and commissioning of 0-15 Kg/sq cm100mm dia Dial type pressure gauge with isolation cock and pipe at hydrant station as per specification.

5

1770

8852.05

... More
90.17.22:Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required

5

1383

6915.85

... More
OD240945/2024-2025:AIR RELEASE VALVE Supply, installation, testing and commissioning of Gun metal Air Release valve 20 mm dia

2

2323

4646

... More
90.17.19.3:Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :3 way - 150 mm dia M.S. Pipe

1

8401

8401.06

... More
90.17.21.1:Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler

240

485

116479.2

... More
90.17.21.2:Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Upright Sprinkler

16

485

7765.28

... More
90.17.21.3:Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Horizontal side wall sprinkler

20

568

11379.2

... More
90.17.21.4:Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Concealed sprinkler

20

1285

25712

... More
90.17.24.3:Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required :150mm dia

3

42486

127459.08

... More
90.17.25.1:Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, centre bracket, stock bar of following sizes complete as required.700mm

20

1236

24736.4

... More
90.17.29:Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

10

211

2114.5

... More
OD240958/2024-2025:Supply and installation of6Kg ABC Fire Extinguisher cap filled with mono ammonium phosphate powder 50% confirms to IS 1409, stored pressure type, with pressure gauge, the discharge time 24 sec, controllable discharge mechanism, jet range 5 meters, average discharge is 90%, appliccable on A,B & C and electrically started fire, A rating-3A, B rating 21B, construction: deep drawn & co2 mig welded, EPDM rubber hose with both end aluminium clamped, internal coating-epoxy powder coating, external coating-pure polyster powder coating(UV resistant),brass forged valves with safety pin is of ss material, sheet metal thickness ISI approved.

16

3147

50362.72

... More
OD240959/2024-2025:Supply and installation, testing and commissioning of 4.5Kg CO2 fire extinguisher, filled with CO2 gas as per IS 15222, control discharge mechanism fitted with minimum 1.5 meter wire braided hose & flat horn with diffuser nozzle for dispersed discharge of CO2, discharge time 37 sec, average discharge is 95%, applicable on class B, C and electrcally started fire, external coating is of enamel spray painting, valve confirm to IS 3224 ISI marked, CO2 cylinder construction: hot spinning by seamless pipes & bearing ISI mark, body confirms to IS 7285 extinguishers to ISI marked. fire rating:89B

8

8510

68082.48

... More
OD241126/2024-2025:Supply and installation, testing and commissioning of Moudlar Fire Extinguisher 5 Kgs. Capacity ceiling mounted ABC Stored pressure type suitable for below ceiling built in 1 piece with body and bottom. . The Extinguisher as per IS:15683-2006 with ISI Mark.

17

11034

187582.25

... More
17.1.1:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of heat detector operating at 54ºC / 57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

9

1257

11318.58

... More
17.1.10:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.

1

82131

82131.87

... More
17.1.2:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.

123

1356

166795.38

... More
17.1.4:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

15

470

7052.85

... More
17.1.5:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning response indicator on surface/ recess MS box having two LEDs metallic cover complete with all connections etc. as required.

30

218

6546

... More
17.1.7:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

15

568

8529.3

... More
17.1.8:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning talk back slave station in surface/ recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/ microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.

15

1060

15911.4

... More
17.1.9.3:Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.10 Zone

1

18700

18700.51

... More
17.2.17:Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required

1

6809

6809.07

... More
17.2.19:Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.

1

1886

1886.8

... More
17.3.6:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.

1

115042

115042.56

... More
17.3.4:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.

15

2871

43078.2

... More
17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

600

170

102390

... More
17.2.14:Supplying, installation, testing & commissioning of addressable manual call point complete as required.

15

4587

68811.3

... More
OD241120/2024-2025:Supply, installation, testing and commissioning of audio alarm hooters .

15

999

14992.95

... More
OD241124/2024-2025:Supply, installation, testing and commissioning of Heat Detector with mounting Base etc. as required.

5

2323

11615

... More
17.5.3.1:Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sq mm

400

60

24108

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

100

99

9928

... More
17.3.3:PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

1

2115

2115.94

... More
OD240978/2024-2025:Supply & erection of 3mm thick PVC foam board Assembly Point sign board 16" x 16"

1

3252

3252.2

... More
OD241140/2024-2025:Supply & erection of 12V 7 Ah Battery for fire alarm panel & talk Back panel etc, as required.

4

1626

6504.4

... More
OD241141/2024-2025:Supply & erection of MICROPHONE for Intelligible, crisp and bright sound suitable for all type of PA applications. Supplied with quick detachable holder with 3-pin professional XLR connector & 6 mtrs. Twin core shielded low noise cable.

1

1626

1626.1

... More
OD241142/2024-2025:Supply, erection, testing and commissioning of 5Watt PA cum Talk Back speaker wall mounted type .

15

1626

24391.5

... More
OD240985/2024-2025:Supply & installation of necessary Glow Sign Board made of 3mm thick PVC foam board as per new fire rules like Fire Station, Fire Exit, passenger Lift, Electrical Duct, Plumbing Duct, Floor level, Fire Lift in each floor and Pump Room

50

754

37749

... More
OD240990/2024-2025:Supply & erection of Fire Escape rout in each floor having minimum size A3 paper neatly prepared by computer aided design and colout printed in high quality paper minimum 100 GSM and laminated and fixed on wall with using transperant acralic sheet with 4 Nos steel button screw etc as required

15

2199

32998.2

... More
OD251508/2024-2025:Charges for Preparetion of CAD drawing , colour printing etc for the Fire NOC from the fire and resue department charges for additional colour photo copy from 1 st sheet

100

23

2323

... More
OD251513/2024-2025:Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as requiredbr

300

19

5991

... More
OD251509/2024-2025:Charges for Preparetion of CAD drawing , colour printing etc for the Fire NOC from the fire and resue department charges for first copy

10

811

8111

... More
SITC of Transformer ( Electrical work )(Electrical work)

-

-

-

... More
OD242760/2024-2025:Supply, Fabrication, Installation, testing and commissioning of dust and vermin proof sheet steel constructed using 2 mm CRCA sheet and powder coated Cubicle type 12 kV, SF6 Ring Main Unit complete (Extensible/Outdoor)(2 Isolator+1 Breaker)FBX-E /12-20/CCT2 /Outdoor- Motorised +Battery Charger.

1

598288

598288.65

... More
OD251071/2024-2025:Supply, conveyance, installation, testing and commissioning of 200 KVA Indoor Type Unitized Substation comprising of H.T. panel trunked with cast resin Transformer with 630A VCB on H.T. side and bottom / top entry cable box as per technical details furnished below. H.T. Portion :H.T. Portion consists of 1 No 11K.V, 630A, 350M.V. A VCB with 2O/C relay with high set elements one E/F relay with DC trip with earth inter lock with main switch and mechanical ON/OFF indication, with shunt trip coil for the remote operation of the VCB. Transformer Portion consists of 200 KVA, 11 K.V, 50 Hz, Delta/Star (Dyn-11) connected cast resin insulated copper wound transformer, Ratio 11KV/433, 3 Phase AN cooled. The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrosion by epoxy resin finish. Class 'F' insulation level shall be maintained. The maximum total loss of the transformer shall meet latest ECBC standards. OFF load tap changing facility shall be incorporated so as to achieve tap position from +5% to -10% in steps of 2.5% changeable by tap links. Temperature scanner with trip annunciator is to be provided. The transformer shall confirm to IS 2026: Part 11 2021/ IEC 60076-11:2018 Dry type Transformer. The transformer shall be subjected to all routine tests as per the relevant IS/ IEC standards and shall have all other standard fittings as per IS: 2026. TOD Metering Facilities consists of 3nos (rating suggested by K.S.E.B) 15VA, 0.2S Class Accuracy Cast resin C.T. 1No 3Phase 3Limb 11KV/110V, 10VA, 0.2 Class accuracy Cast resin P.T. with protective fuses. Provision for fixing TOD meter & test terminal block, (TOD meter and CT, PT unit compartment shall be so fabricated. So as to enable the K.S.E.B authorities to seal it). and including arranging testing and installation of the same with K.S.E.B. Testing Division. LT Portion consists of 1No 4Pole 400A 50KA microprocessor base MCCB inbuilt earth fault with setting range 50-100% with shunt release and rotary handle including NCT and MC12 relay. All inter connection from HT VCB switch to transformer and to LT breaker shall be given using Copper bus bars and support insulators. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side including LT Cable Box. Phase barriers and shrouding as per rules has to be given. The enclosure shall comply to IP 23 standards made of 2 mm CRCA sheet and shall have provisions with Epoxy powder coating the assembly after subjecting to 7 tank processes. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation and efficient Cooling, required including Danger boards, signage, lettering etc. required as per standards. The USS shall be installed at site as per the directions of Engineer in charge.

1

1137835

1137835.27

... More
OD242824/2024-2025:Supply of PVC insulated and PVC sheathed XLPE armored aluminum power cable, 11 KV grade of the following sizes , making good the damages , colour washing etc. as required.3 core 300 sq mm

120

2095

251474.4

... More
8.3.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

100

133

13308

... More
8.4.2:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

20

113

2279.2

... More
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

3

13887

41661.18

... More
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

20408

20408.63

... More
90.12.12.7:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation120/102.5 mm or nearest size

100

552

55296

... More
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

268

268.21

... More
2.22:Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

290

290.26

... More
OD249085/2024-2025:Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

1

470

470.19

... More
OD249081/2024-2025:Supply of 11 KV graded Electrical Hand Gloves

1

987

987.28

... More
OD262737/2024-2025:Supply and fixing three Phase HT Net Trivector Meter 3Phase 4 Wire /5A with an accuracy of Class 0.2S as per the KSEB Standard after testing with terminal block and 20A fuse with HRC link in the existing panel assembly and giving connection etc as required.

1

46619

46619.29

... More
SITC of DG (Electrical work )(Electrical work)

-

-

-

... More
OD263566/2024-2025:Supply ,Conveyance Installation ,Testing and Commissioning of 160 KVA DG set as per the technical details given below. Engine. a. Make of Engine - As specified in accepted list of material. b. Type of Engine-Diesel Engine. c .No. of cylinder- Suitable to develop the required BHP as per manufacturer's standards. d. Method of cooling - Water cooling(with radiator) e. Aspiration - Turbo charged after cooled. f. Design - Suitable for generator set application. g. Out put - BHP at 1500 RPM under NTP conditions or other BHP ratings Specified by the respective manufactures capable of delivering the required power for alternator. Standard accessories with diesel engine. a. Fly wheel housing and flywheel to suit single bearing alternator (Close coupled arrangement).b. Air cleaner, c. Coolent kit.d, Fuel Pump, e Electronic governor backed with mechanical governor. f. Fuel filter. g .Lubricating oil filter, h. Residential type exhaust silencer. Engine Instrument Panel. a. starting switch with key or button .b. Lubricating oil temperature gauge. c.Lubricating oil pressure gauge, d. Water temperature gauge. e.RPM Indicator with hour meter. f. Battery charging ammeter. Safety Controls for Engine-a.Trip for low lubricating oil pressure. b.Trip for high water temperature. c.Providing necessary warning system and other safeties as contemplated in relevant ISS. d.Fuel shut off facility at over speed. Fuel pipe.Oil resistant flexible hoses & 25mm dia or nearest size MS pipe as per manufactures requirement for fuel line. Alternator-a.make-As specified in accepted make of material .b .Type - Self excited and self regulated. capacity - 160 KVA at 0.8 PF. d. System of voltage - 3 phase, 415V. e.Speed - 1500 RPM. f. Voltage regulation band - 2.50% of rated Voltage .g. Insulation - Class F/H. h. AVR - AVR shall be provided with a motorized or solid state potentiometer. i.IP rating of enclosure - IP 23.j. Wave form distortion - No load<1.5%, non-distorting balanced linear load<5%.k.Telephone interference factor - Better than 50 l. Total harmonic factor - Better than 2%. Standard control panel with 400A ,4pole ,50kA MCCB with overload and E/F release and standby low set earth fault relay using neutral CT .The alternator should confirm to IS 4722. Routine tests as per relevant ISS shall be conducted and test reports of the same shall be furnished at the time of delivery. Fuel tank-Integral type fuel tank of adequate capacity . Battery-Required number of suitably rated fully charged battery with leads and terminals as required as per manufactures requirements. Battery Charger :Supply and providing 24V battery charger suitable for charging battery of DG Set (180 Ah) consisting of the following. a. Transformer / Rectifier with surge protection device. b. Charging facility for 12V & 24 V battery. c. DC Volt Meter. d. DC Ammeter to indicate both charging and discharging current.e. Selector Switch for trickle and boost charging. f. Automatic overcharge cut off facility .Acoustic enclosure: a,The DG set shall be supplied along with specially designed company fabricated (to be fabricated in the same company firm where the DG set delivered) acoustic enclosure to meet the stringent MOEF/ CPCB norms of 75 dBA@ 1m at 75% load under free field conditions. b.Sufficient space and clearance shall be maintained inside the enclosure to have optimum serviceability.c.Air inlet louvers shall be designed in such a way as to operate the set at rated load even at 50ºC enclosure temperature. d. The enclosure shall be with UV resistant powder coating capable to withstand extreme environments. e. Hardware used shall be of only stainless steel make, f.Insulation material shall confirm to IS 8183 specification. Documents to be supplied:a.Engine manual, b.Spare parts book, c.Warranty certificate, d.Alternator manual & test certificate, e.1 set control wiring drawing. Installation:It shall be installed in the pre-constructed concrete bed complying to relevant IS standards,IE rules and as per the direction of the official. Testing and commissioning:The DG set shall be tested as per relevant IS standards. Block load testing shall also be conducted.DG has capacity to carry out 55% block load.The load required for testing shall be made available at site by the selected agency at their own expense. During defect liability period ,periodical checkup & services as per manufacturers recommendation and repair shall be arranged and any spare/component which require replacement /repair shall be done immediately at free of cost.

1

2226892

2226892.55

... More
OD251132/2024-2025: Supplying, fixing, of exhaust pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc . adequately supported on rigid supports duly painted with heat resistant paint etc. as per specification and as required complete in all respect. piping of nominal size - 150 mm dia

18

2835

51035.04

... More
OD251133/2024-2025: Supplying, fixing, testing of exhust pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc . adequately supported on rigid supports duly painted with heat resistant paint etc. as per specification and as required complete in all respect. piping of nominal size - 100 mm dia

18

2120

38174.4

... More
16.12.2.1:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

6

1120

6720.72

... More
16.4.3:Supplying, laying/fixing , testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum duly covered with a layer of 120gm/sqm polythene sheet (vapour barrier ) on existing pipe and finally applying 0.63 mm aluminium sheet cladding complete with type 3 grade 1 roofing feltstrip (as per IS: 1322 as amended up to date at joints etc. as per specifications and as required.insulation of thickness 50mm on existing pipe

2

2918

5836.5

... More
OD251145/2024-2025:Supply, conveyance and filling of good grade Diesel fuel.

350

100

35339.5

... More
OD254110/2024-2025:Supplying, fixing testing and commissioning of following Expansion Belows as per specifications. Stainless steel Expansion bellows suitable Generator Exhaust 100 mm dia

1

8481

8481.41

... More
LAN(Electronics Work)

-

-

-

... More
OD116002/2024-2025:Supply, Installation, Configuration, Testing and Commissioning of L3 stackable Data Switch 8 Fiber 10G + 8 Copper 10G, 16 port 10 Gbps Switch ,Supporting networking standards IEEE 802.11ad, IEEE 802.11az, IEEE 802.3ad, IEEE 802.3az Minimum throuhput 320 Gbps, including VLAN configuration and its Documentation, inter VLAN routing configuration etc as required, rack mountable switch with minimum 3 years onsite warranty. Accepted Make HP, Netgear, Brocade, Ruckus or Equivalent

1

195656

195656.71

... More
OD232650/2024-2025:Supply, Installation, Testing and Commissioning of L2+ 24 port 10/100/1000Mbps PoE+ Switch meets IEEE standards 802.3, 802.3u, 802.3ab, 802.3x, 802.1Q, 802.1p, 802.1D and 802.1ad , PoE Power budget 380 Watts or above, with 48 Gbps throughput in full duplex mode having port based VLAN with 2 or more SFP uplink ports, rack mountable switch with minimum 3 years onsite warranty. Accepted Make HP, Netgear. Ruckus, Brocade or equivalent

1

46722

46722.35

... More
OD97271/2024-2025:Supply, Installation, Testing and Commissioning of L2+ 24 port 10/100/1000Mbps PoE+ Switch meets IEEE standards 802.3, 802.3u, 802.3ab, 802.3x, 802.1Q, 802.1p, 802.1D and 802.1ad , PoE Power budget 190 Watts or above, with 48 Gbps throughput in full duplex mode having port based VLAN with 2 or more SFP uplink ports, rack mountable switch with minimum 3 years onsite warranty. Accepted Make HP, Netgear. Ruckus, Brocade,juniper,Cisco or equivalent

4

31536

126147.04

... More
OD232960/2024-2025:Supply, Installation, Testing and Commissioning of Indoor PoE Wireless Access Point - Dual Radio radio (802.11 b/g/n/ax, internal antennas, 1 x 10/100/1000 RJ45 port, Ceiling/wall mount with following features :- WPA3 Support, MAC Filtering ; AP Detection,, Wireless LAN Segmentation , Wireless Isolation, Wireless Broadcast Scheduling, SSID Broadcast Disabling with 3 year OEM onsite Warranty. Accepted Make. Cisco/Juniper/Aruba/DLink or equivalent

5

16523

82616.75

... More
OD97329/2024-2025:Supply and Installation of CAT 6 24 Port Modular type Patch Panel with necessary numbering with permanent marker or by printed means including termination charges Accepted make : Legrand/Molex/AMP

5

5140

25703.25

... More
OD97261/2024-2025:Supply and fixing Cat-6 Information outlet with spring shutter front access in recess with metal back box /on surface with PVC back box for inter connection of nodes and switches including termination charges. Node numbers should be neatly written in I/O ports. Accepted Make :- Molex/ Legrand/Actassi/Belden/Panduit.

25

435

10889

... More
OD97269/2024-2025:Supply Installation Testing and Commissioning of 24 Port loaded 1U Rack mountable LIU with Splice tray ,pigtails and cable management. Warranty 3 years. (all available LIU ports should be linked to corresponding optical fibers) Accepted Make: Molex, AMP,Legrand.

1

22012

22012.46

... More
OD97224/2024-2025:Supply, Installation, Testing and Commissioning of 6 port rack mountable LIU with splice tray, pigtails and cable management.(all available LIU ports should be linked to corresponding optical fibers).Warranty:3 years.

5

4706

23530.55

... More
OD232561/2024-2025:Supply, Installation, testing and commissioning of Single-mode duplex SFP Module compatible with switches. Warranty: 3 years. Accepted Make: Juniper, HP, Netgear, Syrotech.

10

3484

34845

... More
OD232778/2024-2025:Supply, installation,testing and commissioning of 1KVA Line interactive UPS, OutputPowerCapacity800Watts/1000 VA, Output Frequency (sync to mains)50/60Hz+/-3 Hz with 42AH SMF battery for 2hours backup. Warranty: 3 year. Accepted Make: Hykon, APC/Equivalent

5

16261

81305

... More
OD232781/2024-2025:Supply and installation 3 KVA Online UPS having the following minimum specifications: Output : 220 V/230 VAC ± 1 %, 50 Hz ±1% sine wave single phase, Input: 160V to 280 V, 45-55 Hz single phase, Rating : 3 KVA, double conversion technology, IGBT rectifier, automatic battery charge in UPS OFF mode, The system shall comply to ISO 9001:2015, ROHS, ISO 14001:2015 certifications. Battery bank : 10800 VAH or higher, tubular Batteries with Suitable Battery rack , Indications: Load on Mains, Load on Battery, battery Low, Overload, UPS Fault. UPS warranty: 3 years or above, Battery warranty: 3 years or above. Accepted Make for UPS :APC, Hykon, Igatech, Numeric and Battery Exide, Amaron.

1

131890

131890.36

... More
CCTV(Electronics Work)

-

-

-

... More
OD116326/2024-2025:Supply and installation of Network Video Recorder, support 32 Channel, Should support Resolution:- ≥ 4 MP IP Camera, Network Bandwidth 320Mbps for access,320 Mbps for storage and 320 Mbps for forwarding, support for H.265 encoding format streaming access and decoding output, Video standard 30fps, Monitoring image quality 1080p, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Back up way: Support U disk, USB mobile, HDD, USB DVD-RW, network storage and back up, Video output: HDMI/VGA/TV, External Audio out put: 1 ch RCA, External network port: RJ 45(1), 10/100/1000 LAN port, RS455 port: Full duplex standard 485 port, USB port: USB3.0(1), 2.0(2), Wireless port: WiFi, Support 4 SATA HDDs (up to 32 TB), Each port supports MAX 8TB HDD. Wireless mouse.Warranty 3 year Accepted Make: Plexonics, Honeywell, Avtron,CP Plus,Dahua or Equivalent

2

38454

76908.84

... More
OD97367/2024-2025:Supply, Installation, configuration, Testing and Commissioning of 5 Mega Pixel fixed focus (IP 67) Bullet camera with 40 meter IR length, with following specifications: Focal length 2.8mm, Image Sensor 1/2.7 inch Progressive Scan CMOS. Max. Resolution 2560 X 1920 Min. Illumination Color: 0.005 Lux @ (F1.6, AGC ON), B/W: 0 Lux with IR lens Mount M12 , Aperture F1.6, Wide Dynamic Range (WDR) 120 dB, Image Enhancement BLC, HLC, 3D DNR, Ethernet Interface 1 RJ45 10 M/100 M self-adaptive Ethernet port. Built in Microphone, Built-in memory card slot, support microSD card, up to 256 GB , Protection IP67 (IEC 60529-2013); IK10 (IEC 62262: 2002) with all necessary mounting brackets, back box as required, with 3 year OEM onsite Warranty .Accepted make:-Honeywell, Dahua, CP Plus, Hikvision, Hanwa.

20

6940

138819.4

... More
OD97368/2024-2025:Supply, Installation, configuration, testing and commissioning of 5 Mega Pixel Vandal proof (IP67, IK10) fixed focus IP Dome camera with 40 meter IR length, with following specifications: Image Sensor 1/2.7 inch Progressive Scan CMOS. Max. Resolution 2560 X 1920 Min. Illumination Color: 0.005 Lux @ (F1.6, AGC ON), B/W: 0 Lux with IR . Fixed focal lens, 2.8, (WDR:120 dB, Image Enhancement BLC, HLC, 3D DNR IGMP, 802.1X, QoS, IPv6, IPv4, UDP, SSL/TLS. Ethernet Interface 1 RJ45 10 M/100 M self-adaptive Ethernet port. -SF: Built-in memory card slot, support microSD card, up to 256 GB Audio - 1 input (line in), Protection IP67 (IEC 60529-2013); IK10 (IEC 62262: 2002) with all necessary mounting brackets, back box as required, with 3 year OEM onsite Warranty . Accepted make:-Honeywell, Dahua, CP Plus, Hikvision, Hanwa or equivalent

35

6534

228705.75

... More
OD97373/2024-2025:Supply, Installation, Testing and Commissioning of of project series 5 MP IR Motorized vari-focal IP bullet camera with 1/2.7 inch Progressive Scan CMOS image sensor, IR range not less than 60 meters, Focal Length- 2.7-13.5 mm , WDR 120dB, IP67 protection, Video Compression H.265; H.264; H.264B; MJPEG, Noise reduction:3D DNR, Perimeter protection: Tripwire, intrusion (Recognistion of human and vehicles) , Work together with Smart NVR to perform refine intelligent search, event extraction and merging to event videos, 3 video streams, ONVIF( S/ G/T);CGI;P2P;Milestone: Genetec and other accessories with 3 years onsite warranty. Accepted Make : Honeywell, Dahua, CP Plus, Hikvision, Hanwa.

5

22330

111654.25

... More
OD97370/2024-2025:Supply, Installation, Testing and Commissioning of 55 inch 4K UHD LED display with resolution 3840x2160 (UHD) Connectivity : HDMI 2.0(3) , USB 2.0 x 1, RJ 45 x 1, Headphone out x 1, 167 Application, Built in blutooth ver.4, and with wall mounting Kit, all necessary HDMI cables and connectors.Warranty: Three year onsite OEM warranty Accepted Make: LG/Samsung/Sony/Panasonic

1

66205

66205.5

... More
OD97372/2024-2025:Supply and installation of 6mts Outdoor Pole with 80mm base diameter fixed with bolts to a cement concrete1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate) foundation of minimum size 30cmx30cmx 45 cm(45 cm below ground and 15cm above ground) properly finished with painting (2 coat) with camera mounting accessories.

3

5807

17422.5

... More
OD232512/2024-2025:Supply and installation of 8TB SATA for video recording 24x7 reliability, reduced power consumption, Compatible and minimum three years warranty. Accepted Make : Western digital / Seagate or equivalent

5

19164

95823.75

... More
General Announcement & PA System for Conference Hall(Electronics Work)

-

-

-

... More
OD232527/2024-2025:Supply, testing and commissioning of Two Zone Power Amplifier with 400 W RMS power output ,minimum 6 mic inputs, 2 Aux, 1 Line, bass & treble controls, Frequency response:50-15000 Hz,4 ohm,8 ohm,70 V and 100 V Speaker outputs for each zone, built-in digital player with USB,SD and MMC Card Reader and remote control and including necessary cables and connectors. Accepted make and model : AhujaTZA4000DPM or equivalent

1

39352

39352.43

... More
OD232528/2024-2025:Supply, Installation, testing and commissioning of Power Amplifier with 250 W RMS power output, minimum 5 mic inputs, 2 Aux, 1 Line, bass & treble controls, built in digital player with USB and Memory card support, Frequency response:50-15000 Hz,4 ohm,8 ohm,70 V and 100 V Speaker outputs ,USB port and including necessary cables and connectors. Accepted make and model: Ahuja SSA-250DP or equivalent.

1

26976

26976.85

... More
OD232944/2024-2025:Supply, installation, testing and commissioning of high fidelity 2-Way speaker system with power rating - 60W RMS Max, power taps - 60/40/30/20/10W on 100 V line with power tap selection through a slotted rotary switch knob, frequency response -50-20,000Hz, SPL at 1kHz (1W/1m)- 87dB and with necessary wall mounting bracket and with Three years onsite warranty. Accepted model: Ahuja ASX 612 BT/WT or equivalent.

4

7301

29204.16

... More
OD232529/2024-2025:Supply and connecting 20W RMS PA column speaker (white) with 100V line matching transformer and power taps of 20/15/10/5W, frequency response 150-10000 Hz. Accepted make and model : Ahuja ASC 320T or equivalent.

10

4750

47509.5

... More
OD119088/2024-2025:Supply, Installation, Testing and Commissioning of 21 inch Phatom Power Table top gooseneck microphone with on/ off switch and on/off indicator ring, Accepted Make/ shure/Toa/EV or equivalent with 3 year onsite warranty.

6

11615

69690

... More
OD119089/2024-2025:Supply, installation, Testing and commissioning of Wireless Handheld Microphone System with SVX4 receiver, SVX2 Handheld microphone transmitter with PG58 microphone -Upto 4 compatible systems , Antenna switching Diversity, Adjustable Squelch Level,1/4inch and XLR output, AA type batteries including microphone holder with min. 3 year onsite warranty. Accepted Make and Model :- Shure SVX24 and PG58 or equivalent

2

27980

55961.9

... More
OD119090/2024-2025:Supply, Installation, testing and Commissioning of 48V Phantom power injector with following specifications:-Operating voltage 240V AC 50Hz, Phantom supply 48V, Dc, Mic inputs 2x Female XLR, Mic outputs 2x male XLR( For amplifier), Accepted Make and model: Ahuja APS 482 or equivalent

5

4408

22040.45

... More
OD119091/2024-2025:Supply of microphone floor stand with height adjustment 920-1500 mm and base diameter 230 mm. Accepted Make and Model: Ahuja DGN or equivalent

1

1161

1161.5

... More
OD119092/2024-2025:SIupply, Installation, testing and Commissioning of PA microphone having frequency response 50-16000 Hz, sensitivity 2mV/Pa and with quick detachable holder with 3 pin XLR connector & 10 mtrs.twin core shielded low noise cable and with 3 years onsite warranty. Preferred model: Ahuja ASM-580XLR "

1

284

284.77

... More
OD119093/2024-2025:Supply of microphone table stand with height adjustment 350-530 mm and base diameter 150 mm with min. 3 year onsite warranty. Acceped Make and Model: Ahuja DGT or equivalent

1

1045

1045.35

... More
OD228603/2024-2025:Supply, Installation, Testing and Commissioning of Digital Display unit with software capable of displaying notice board in multiple formats , input from (minimum 3)LAN network, Display software Should be supplied by panel OEM and to be configured for 3 computers with below specifications:- Screen size (cm) 127CM (50)Panel Technology IPS Back Light Type DirectAspect Ratio 16:9 Native Resolution 3840x2160 (UHD)Refresh Rate 60Hz Brightness 400nit (Typ.)Contrast Ratio 1,200:1 Dynamic CR 1,000,000:1Color Gamut DCI 80% Viewing Angle(H x V) 178 x 178Color Depth 10 bit(D), 1.07Billion colors Response Time 12ms (G to G) Surface Treatment(Haze) 3% Life time 30,000Hrs (Min)Operation Hours (Hours/Day) 16/7 display mode : Portrait / Landscape CONNECTIVITY Input HDMI (3), RS232C IN (1, 4pin Phone-jack), RJ45 (LAN), USB2.0 Type A (2)Output Audio Out, RS232C OUT (1, 4pin Phone-jack) Hardware Internal Memory 8GB, Wi-Fi Built-in, Temperature Sensor, Auto Brightness sensor, Local Key Operation (Power On/Off ) Software web OS ver. (webOS6.0), Embedded CMS (Local Contents Scheduling, Group Manager), USB Plug & Play, Fail over, Background Image (Booting Logo Image, No Signal Image), Sync Mode (RS-232C Sync, Local Network Sync), Screen Share, Video Tag (4, Max One HDMI input), Play via URL, Rotation (Screen Rotation, External Input Rotation), Gapless Playback, Setting Data Cloning, SNMP, ISM Method, Auto Set ID, Status Mailing, Control Manager, 3rd Party Compatibility (Cisco certi (TBD (Jun~)), Crestron Connected), Power (Smart Energy Saving, PM mode, Wake on LAN, Network Ready), Beacon, HDMI-CEC, SI Server Setting, webRTC Warranty 3 year onsite OEM, Accepted Make: LG/Samsung

1

70214

70214.71

... More
OD228606/2024-2025:Supply, Installation, Testing and Commissioning of 75 inch IPS interactive screen Screen size (cm)190.5 cm (75)Panel TechnologyIPS Back Light TypeDirect Aspect Ratio16:9 Native Resolution3840x2160 (UHD)Refresh Rate60Hz Brightness350 nits Contrast Ratio1,200:1 Viewing Angle(H x V)178 x 178 Color Depth10bit, 1.07Billion colors Surface Treatment(Haze)Anti Glare, 7H(Mohs) Operation Hours (Hours/Day)16/7 Input - Video / AudioHDMI (3), RGB / Audio In Input - External ControlRS232C In, RJ45 Output - Video / AudioAudio Out / Optical Output HWInternal Memory (32GB), SoC ( Dual core A73+Dual core A53), DDR(3GB), Wi-Fi(Builtin, Slot type), Power Indicator, Local Key Operation(1, Power button)SWAndroid 8.0 Speaker (10W x 2) ACCESSORY Included with Display Power Cord 3 M*1, USB Cable (Type A-Type B) 5 Mx1, HDMI Cable 3 Mx1, Writing Pen x 2pcs, QSG, Remote Controller(include battery 2ea), Wi Fi module with necessary HDMI cables. Warranty :3 year onsite OEM. Approved Make LG/Samsung or equivalent

1

188687

188687.71

... More
OD228607/2024-2025: Supply of Laptop Processor: Intel Core i5 , Memory: 16 GB DDR4 RAM , 512 GB M.2 NVME SSD, Screen Resolution: 1920x1080 (Full HD), Display Size: 14&quot; ,Wireless connectivity: Integrated wireless 801.11ac, Integrated Bluetooth, Speaker: Integrated Stereo Speaker, Keyboard: Keyboard with Touch Pad, Camera: Integrated HD Camera, Audio: Integrated, Expansion Port: 2 USB Port ,1 Ethernet port , 1 HDMI port, 1Head phone/Microphone combo or Separate &amp; other Standard features, Power Supply : 230V, 50Hz AC Supply with rechargeable Battery Pack comprising of Li-Polymer battery, Mouse: Optical Scroll mouse Carry case: Backpack Weight: Less than or equal to 1.8 Kg, Warranty: 3 year comprehensive onsite. Certification: ROHS Compliance &amp; BIS for Product Operating System: Windows 11 Home Accepted Make : HP/Dell/Acer/Lenovo or equivalent

1

69690

69690

... More
OD232530/2024-2025:Supply and fixing Custom made floor/wall Rack for keeping Amplifier and other hardware with 1 nos of tray, AC distribution box with Power Distribution Unit to provide power supply to system and all necessary accessories

2

6069

12139.7

... More
OD117836/2024-2025:Supply and Installation of Wireless Presenter having the following features, batteries operated, Connectivity Type wireless, Wireless Type ‎802.11a etc USB Hardware Platform, Included Components Wireless Presenter TXD/RXD, 2 AAA batteries, Carrying case, Quick-start guide. Durable to long last and have warranty for 3 years.

1

2787

2787.6

... More
Cables, Conduits and other accessories(Electronics Work)

-

-

-

... More
OD98456/2024-2025:Supply, laying and testing (using fluke micro scanner in presence of competent PWD staff) of 4 pair 23AWG outdoor Cat-6 UTP cable through surface/existing PVC Conduits/ as required. Accepted Make: Molex/Actassi/Belden/ Systimax

4800

79

382416

... More
OD98470/2024-2025:Supply, laying, splicing and termination of 6 core armoured single mode optical fiber cable including testing charges :Accepted Make:- Finolex, Molex

400

57

23152

... More
OD98452/2024-2025:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm. Accepted Make:- Precision, Toms, Balco

850

99

84388

... More
OD98453/2024-2025:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm. Accepted Make:- Precision, Toms, Balco

600

107

64488

... More
OD232513/2024-2025:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the necessary accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

100

1087

108796

... More
OD232535/2024-2025:Supply and laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size including concrete cutting and refilling

70

289

20273.4

... More
OD232537/2024-2025:Supply and providing Duplex LC/UPC-SC/UPC patch chord 1 meter. Accepted make: Molex, Actassi, Belden, Systimax

10

1202

12021.5

... More
OD232540/2024-2025:Supply and providing Duplex LC-LC Patch chord 1 mtr. Accepted Make: Molex/Actassi/Belden/ Systimax

1

1202

1202.15

... More
OD232541/2024-2025:Supply of 3 mtr factory crimped UL Listed, ETL Listed and RoHS Complaint. CAT 6 having 0.5mm thickness. Accepted Make: Molex, Legrand, Honeywell, Amp

20

260

5203.6

... More
OD232542/2024-2025:Supply and Installation of UL Listed, ETL Listed and RoHS Complaint. CAT 6, 1Mtr standard factory crimped patch cord. Accepted Make: Molex, Actassi, Belden, Panduit.

90

216

19443.6

... More
OD232536/2024-2025:Supply and installation of 19inch 22U Rack with 600x800mm (WxD),front and rear lockable door, removable side panels, caster wheels and levelers, supporting static load of minimum 750kg on caster stand, cooling fan 4 Nos, vertical and Horizontal cable managers, power distribution units and all other accessories as required. Accepted make: Netrack /Rittal/Valrack.

1

26429

26429.87

... More
OD232538/2024-2025:Supply and fixing 19inch 6U (500mm depth) wall Mount Rack for switches with cable manager , cooling fan-2 numbers, AC distribution box and all other accessories. Accepted make:- Netrack / Valrack

5

6017

30086.9

... More
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm

400

49

19672

... More
OD232777/2024-2025:Supply and fixing of Cable cubby with 1HDMI 2.0 V, 1VGA, 1 USB charger, 1Power,1Audio and 1LAN. Warranty:3 years Accepted Make and Model : Logic LG 501H or equivalent

1

10558

10558.45

... More
OD233015/2024-2025:Minor Electrical works for the distribution of power to rack with all accessories including 2.5sq mm copper conductor, 20mm PVC conduit and connection from DB/main power source along with labor cost as required.

1

4065

4065.25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.