Public Works Department Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Jul 2024
Closing Date9 Aug 2024
Tender Amount₹ 1,27,033 
Notes
Download

Costs

Summary

General Annual Maintenance Contract Of Electrical Installation At 5 Nos Rest Houses Under Pala Sectionpala Arunapuramvaikomkaduthuruthy Erattupetta Rest Houses For The Period 2024-2025

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

20

1292

64.62

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

20

1796

89.83

... More
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

33

3296

99.9

... More
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture

15

18339

1222.65

... More
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

3

3757

1252.63

... More
OD76395/2024-2025:Supply and providing 20W, 1200mm LED Tube in the existing box type fittings after providing necessary alterations in the wiring of the fittings and make it good working conditions.

22

9790

445

... More
OD221273/2023-2024:Supply and providing the following types and power rated lamps in the existing fittings as required 9W LED bulb -

18

2018

112.16

... More
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.

5

539

107.86

... More
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

1

2379

2379.16

... More
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

1

4621

4621.67

... More
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply

11

24248

2204.42

... More
OD221275/2023-2024:Supply, installation, testing and commissioning of 3 Ltr, 3KW instant water heater and giving connections as required. (Make: V- Guard, Racold, Crompton, Havells Bajaj ) --

1

4552

4552.36

... More
OD221276/2023-2024:Supply and replace the existing defective heating element of existing 10 ltr capacity storage geyser with new one and make it suitable in good working condition ( 2000W)

1

723

723.4

... More
OD221277/2023-2024:Supply and replace the defective thermostat with new copper thermostat suitable for 10 to 30 Liter storage type water heater (16 A, 230 V AC with re set button- 20A 230V AC), cut out, compatible with v guard, racold, crompton,orient, kenstar...etc geyser thermostat.-

1

589

589.82

... More
OD221278/2023-2024:Supply and fixing LED Bulk head with IP65 protection, suitable for surface and wall mounting application including giving connection etc as required ( Philips make WT140W LED7S CW PSU S1 PC or equivalent Make) -

2

1935

967.72

... More
OD221279/2023-2024:Supply Conveyance and installation of Wall mounting Light fixture with poly carbonate body suitable for 1X9 watts LED Lamps fixing directly on wall and giving connections as required. (Havells make (Sl.No: LHDL06160099) or equivalent) --

2

2078

1039.32

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

10

1020

102.08

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

5

787

157.55

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

15

1991

132.77

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

5

1045

209.07

... More
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

10

4089

408.97

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

1

290

290.59

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

1

319

319.9

... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

1

457

457.93

... More
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

3

409

136.39

... More
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

3

459

153.02

... More
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

3

703

234.64

... More
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

10

783

78.32

... More
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

2

219

109.79

... More
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

2

300

150.43

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

5

1192

238.59

... More
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

995

995.4

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

404

404.99

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

3141

3141.15

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

1

988

988.18

... More
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

3022

3022.3

... More
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

2305

2305.33

... More
OD221333/2023-2024:Supply and changing the damaged 2.5mfd capacitor

10

1276

127.68

... More
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top

2

246

123.23

... More
OD221280/2023-2024:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 250 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C -

1

1564

1564.85

... More
OD221281/2023-2024:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C-

1

1791

1791.25

... More
OD221366/2023-2024: Supply Conveyance and installation of Linear compact 7 watts LED mirror lamp with Aluminum body fixing directly on wall with company fabricated clamp and giving connections as required. ( LUM7W LLT004 or equivalent)

5

5011

1002.27

... More
OD221468/2023-2024:2 Way neutral link mounted on SMC sheet

1

151

151.24

... More
OD221469/2023-2024:32 A HRC fuse link with base

1

165

165.28

... More
OD221500/2023-2024:63, HRC Fuse Base with HRC Fuse link

1

254

254.13

... More
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N

1

2482

2482.02

... More
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N

1

3497

3497.23



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.