Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Aug 2024
Closing Date6 Sep 2024
Tender Amount₹ 16,27,090
Costs
EMD
₹ 40,677Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_686142_2Bid Award Id
ViewTender No
EDT_ET_10_2024_25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
OD121930/2023-2024:Wiring combined plug point together with the light point/ fan point/ exhaust fan point/ call bell point including 6 A 5 pin modular socket controlled by 6A one way modular switch in the existing switch board and giving connection to the phase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable ( Green wire for earthing) etc as required.
8
-
-
OD43068/2024-2025:Supply, conveyance, installation, testing and commissioning of 1200 mm ORIENT JAZZ make BLDC ceiling fan or its equivalent make size using standard accessories, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep, Dust proof coating, Auminium blade, double ball bearing with remote control, BLDC 5 star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades working on 140V/285V single phase AC 230 m3/min 350 rpm Pf 0.9 33 watt ORIENT JAZZ, Orbes White with remote control make 1200 or its equivalent make
16
-
-
OD49371/2024-2025:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
14
-
-
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
30
-
-
OD44649/2024-2025:Supply and fixing Conveyance, installation, testing and commissioning of 1000 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea directly on ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
20
-
-
OD42565/2024-2025:Supply, conveyance, installation, testing, and commissioning of a decorative Wall light having a dimension of 150x210x190mm , with a body made of aluminum and glass, painted with imitation gold, featuring an E27 lamp base with a maximum wattage of 12W, including a 6W warm white LED bulb . The scope also includes making necessary electrical connections as required. (Model No. Philips 800052 or equivalent).
36
-
-
OD124861/2023-2024:Supply, conveyance, installation, testing, and commissioning of a mirror LED light with a wattage of 10W and a luminous efficacy of 1000 lumens per watt, having dimensions of 300x65x130 mm. The light features a body made of MS with a polycarbonate diffuser and a chrome finish. The scope also includes making the necessary electrical connections as required. (Model No. Philips 582109 or equivalent).
22
-
-
OD121944/2023-2024:Supply and fixing LED integrated type 2 Watt Warm White 3000K Step Light fittings made of Aluminium Die Cast having dimension W-85MM, L-85mm H-32MM and giving connection etc as required.
22
-
-
OD42501/2024-2025:Supply and fixing Conveyance, installation, testing and commissioning of 6W LED deep Recess mounted Down light 3000K (WW) CCT, with wide beam reflector in 24 degree beam of Philips LED Module (make:Philips 6W RS262B LED 6S/865 PSU MB WH COB LED or equivalent and all accessories giving connection etc as required
110
-
-
OD44653/2024-2025:Supply Conveyance, installation, testing and commissioning of 6W LED bulk head fittings suitable for surface and wall mounting output greater than 115 lumen/W 6500 K with IP 66 protection and IK09 protection with power factor greater than 0.95 at full load, internal surge protection up to 4 KV,and corrosion proof LM6 grade pressure die cast aluminum body & poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required Philips endura or its equivalent
3
-
-
OD42502/2024-2025:Supply and fixing Conveyance, installation, testing and commissioning of round surface fitting made of Aluminium pressure die cast , having efficacy not less than 110 l/w, PHILIPS make:SM295C LED6S-3000 PSU WH SM295C LED6S-3000 PSU WH or equavalent directly on ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
30
-
-
OD44680/2024-2025:Supply, conveyance, installation, testing, and commissioning of a decorative pendant light having a dimension of 230x230x1200 mm , with a body made of aluminum and glass, painted with imitation gold, featuring an E27 lamp base with a maximum wattage of 12W, including a 9W warm white LED bulb . The scope also includes making necessary electrical connections as required. (Model No. Philips 800051 or equivalent).
32
-
-
OD124628/2023-2024:Supplying and fixing Electronic Chime Bell 2 module suitable for single phase, 230 volts, complete as required.
22
-
-
OD121946/2023-2024:Supply Conveyance, installation , testing and commissioning of exhaust fans of size 150 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C existing opening, fixing with 150MM diameter PVC pipe and necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
22
-
-
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
22
-
-
OD44993/2024-2025:Supplying and installing following size with slotted GI channel for cable / pipe support having Minimum size 41 x 21 x 1.5 mm with suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 250 mm width slotted channel provided 60 cm intervals
155
-
-
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
7
-
-
90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
7
-
-
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
1
-
-
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
1
-
-
90.9.2.24:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat Tee
2
-
-
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
2
-
-
90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover
5
-
-
90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer
2
-
-
OD128113/2023-2024:Supplying and fixing 30/25 x 15/12mm PVC trunking ivory/ white colour in surface/ recess including cutting the wall and making good the same in case of recessed conduit along with accessories coupler/elbow/bent etc as required
75
-
-
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
190
-
-
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
230
-
-
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
149
-
-
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
230
-
-
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
75
-
-
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
25
-
-
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
25
-
-
1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
250
-
-
1.19:Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
200
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
250
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
22
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
50
-
-
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
342
-
-
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
45
-
-
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
90
-
-
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
45
-
-
1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
22
-
-
1.24.7:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
22
-
-
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
22
-
-
OD125109/2023-2024:Supplying and fixing following modular type combined twin USB charger on the existing modular plate & switch box including connections but excluding modular plate etc. as required.combined twin USB charger .
8
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
30
-
-
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
20
-
-
OD43937/2024-2025:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. modular type 2 module 16A Key tag
22
-
-
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
118
-
-
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
18
-
-
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
14
-
-
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
52
-
-
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
24
-
-
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
4
-
-
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2
-
-
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2
-
-
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2
-
-
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
60
-
-
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
6
-
-
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
6
-
-
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2
-
-
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2
-
-
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
4
-
-
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
37
-
-
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
4
-
-
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
80
-
-
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
8
-
-
OD121960/2023-2024:Supply and fixing of water proof (transparent)box(size150x150x100)for fixing Contactor MCB/Isolator with using suitable din channel etc.as required .Hensel or equivalent make
22
-
-
OD121962/2023-2024:Supply and fixing 25 A, 3 pole power Contactors AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC
22
-
-
OD121963/2023-2024:Labour charges for dismantling of water heater including conveyance and stacking in the store room
22
-
-
OD121966/2023-2024:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of TELEPHONE/TV DB including Krone/ Splitter rail suitable for fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required.
6
-
-
OD121967/2023-2024:Supply and fixing telephone 10 pair 2 way Krone connector in the existing DB and giving connection as required
3
-
-
OD124440/2023-2024:Supply and fixing 4 Way Splitter for Cable TV in the existing DB and giving connection as required
8
-
-
OD122009/2023-2024:Supply and fixing of water resistance Bakelite Hylam Sheets 4 mm thickness including cutting suitable size and fixing with on the wall with suitable size of bolt etc as required
5
-
-
OD121973/2023-2024:Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as requiredbr
50
-
-
OD122008/2023-2024:Charges for dismantling the existing EI, complete including outdoor post with fittings , making good the damages of walls and conveying the dismantled materials to section store.
100
-
-
OD44910/2024-2025:Supply, Conveyance,Testing and Commissioning of vertical wall mounting type 5 star rated 3L 3KW Vertical Instant Water Heater (Geyser), copper container with puff insulation and PVC body working on 230 Volt 50 Hz A/C supply , fixing on wall using suitable size anchor bolt / Screws etc and giving connection of water line and electrical supply. (Racold Altroi+ 3L 3KW Vertical Instant Water Heater (Geyser) White) or its equivalent)
3
-
-
OD44931/2024-2025:Installation, testing and commissioning of Water Heater (Geyser), copper container with puff insulation and PVC body working on 230 Volt 50 Hz A/C supply , fixing on wall using suitable size anchor bolt / Screws etc and giving connection of water line and electrical supply.
19
-
-
OD44932/2024-2025:Supply and fixing circular PVC lid with screw suitable for 20/25 mm PVC junction boxes.
30
-
-
OD44958/2024-2025:Supply and fixing of 2 feet water inlet and outlet hose pipe for Water Heater (Geyser) and with all accessories and giving connections etc as required
44
-
-