Public Works Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 17,926Document Cost
₹ 1,585Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_656273_1Bid Award Id
ViewTender No
ESDT(ET)167/AEE/23-24Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://www.keralapwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
OD47247/2023-2024:Supply, Installation, Testing and Commissioning of Harddrawn Refrigerant Copper Piping insulated with 13 mm thick nitrile rubber tubings approved make, the price quoted shall be inclusive of proper supports. size: 22.23 mm
25
-
-
OD161554/2023-2024: Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting (in accordance with SMACNA standards)complete with neoprene rubber gaskets, elbows, splitter dampers, bends, transformations, vanes, , inspection doors , plenums hangers, supports, angle iron flanges , Hi Tech/ Hilti GI supports, GI full thread rods , anchor bolts ,GI nuts and bolts etc as per approved drawings and specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 22 SWG( 0.3973mmthick)
30
-
-
OD47300/2023-2024:"Supply, installation and testing of thermal insulation of ducts using closed cell Nitrile Rubber insulation with recommended adhesives and sealed with black adhasive tape and density of material shall be 40-60 kg/cubm. (Make : Armaflex/K-Flex/ALP)" 13mm Thick Nitrile Rubber
30
-
-
OD47303/2023-2024:Supply, installation and testing of acoustic lining with 10 mm thick open cell nitrile foam on the inner side of ducting including providing, fixing and finishing the same as per specifications for ducts as required density of material shall be 140-180 kg/cubm (Make : Armaflex/K-Flex/ALP)
15
-
-
OD47269/2023-2024:Supply and fixing of the fire retardant type canvas for inter connecting cooling unit with duct/pleanum and fixed infront area of the unit to avoid excess vibration with required accessories.
2
-
-
OD47254/2023-2024:Supply and filling Refrigerant R 410 A gas
10
-
-
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
35
-
-
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
30
-
-
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
65
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
8
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
25
-
-
OD47262/2023-2024:Supply, installation, testing and commissioning of insulated condensate drain piping out of PVC- 6g/cm2 pipes complete with hangers/supports/clamps/Clips and all ,fittings etc. and insulated with 13mm thick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-25mm dia
10
-
-
OD47359/2023-2024:SITC of manual damper
5
-
-
16.16.a:Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
1
-
-
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
1
-
-
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
27
-
-
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
3
-
-
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
10
-
-
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
30
-
-
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
100
-
-
OD50270/2023-2024:Supply and installation of FP enclosure for independent mounting of MCB/ RCCB/ RCBO/ isolator
2
-
-
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
3
-
-
OD50479/2023-2024:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 4 sqmm-16 sqmm with 12 mm wide x 1 mm thick clip
4
-
-
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
4
-
-
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2
-
-
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
3
-
-
OD47258/2023-2024:Dismantling charges of Exsisting ductable units