National Institute Of Technology Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 7,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NITC_816916_1Bid Award Id
ViewTender No
Engg/EMU/JE2/19/EleTr/2024-25Tender Authority
National Institute Of Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
10
-
-
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
35
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 x 1.5 sq. mm
110
-
-
3 x 2.5 sq. mm
60
-
-
6 x 4 sq. mm
60
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
225
-
-
25 mm
54
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
3 pin 5/6 A socket outlet
4
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
4
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
8
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
8
-
-
Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ianored)
12
-
-
MCCB, MCB & DB'S
-
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required including suitable enclosure or industrial work.
-
-
-
100A, 16kA, 4 pole MCCB, 415 V
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way , Double door
1
-
-
16 way, Double door
1
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
10
-
-
Triple pole
4
-
-
Four pole
4
-
-
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
16
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40A
1
-
-
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
6
-
-
Supplying and fixing DP/FP/TP sheet steel enclosure on surface/ recess without MCB complete with connections, testing and commissioning etc. as required.
8
-
-
Supply and fixing of following Industrial sockets complete with connections, testing and commissioning etc. as required.
-
-
-
Supplying and fixing 20A , 2P+E, 240 V, Metra plug socket complete with connections, testing and commissioning etc. as required.
6
-
-
Supplying and fixing 40 A to 63 A rating, 240 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40-63 A Double pole
1
-
-
40-63 A Single pole
1
-
-
Supplying and fixing 3 phase following way double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
-
-
-
8 way (8+24)
1
-
-
Supplying and fixing following rating, 250V, 6 kA, DC miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
6-32A SP
4
-
-
6-32A DP
4
-
-
40-63A SP
1
-
-
40-63A DP
1
-
-
EARTHING
-
-
-
Supply and laying of one number 8 SWG good quality bare copper conductor for loop earthing along with existing XLPE insulated PVC sheathed armoured power cable as required.
60
-
-
MV CABLE LAYING
-
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
35
-
-
MV CABLE JOINTING & END TERMINATION
-
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3% X 50 sq. mm (35mm)
2
-
-
MISC. CIVIL ITEMS
-
-
-
Supplying and fixing of 8/10 mm "S" type steel fan hook including chipping,welding, painting making good the damages etc. as required
2
-
-
BLDC
-
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 235 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
2
-
-
ELECTRICAL FIXTURES
-
-
-
Supply and fixing of following Wall mount Fan with necessory arrangement
-
-
-
Supply and fixing of 450 mm sweep wall mount fan with Aluminium blades, 1350RPM, minimum 100 CCM air delivery Wall mount Fan with necessory arrangement (Crompton Sstorm2 Wall mount or equvalent )
4
-
-
Supply and fixing of following Exhaust Fan with necessory arrangement
-
-
-
Supplying and fixing of heavy duty 300mm sweep exhaust fan speed1400rpm including connection etc. as required. Make:havells/almonard or Equivalent
2
-
-
CABLE
-
-
-
Supply of PVC/ XLPE Aluminium Armoured Cable, 650/1100V. Grade confirming to IS:7098 (Pt-1)1988
-
-
-
3.5X50 Sq.mm.
30
-
-
Supplying and fixing of following size ISI marked PVC insulated and PVC sheathed copper multi-core shaethed bright annealed bare copper flexible cables for voltage grade 1.1 KV grade as required.(Make:Finolex,RR cable,KEI or equvalent) including necessory clamps, screw etc. as required.
-
-
-
3 Core 4 sqmm
20
-
-
PANELS AND ACCESSORIES
-
-
-
PANEL ACCESSORIES
-
-
-
Supply and fixing of MCCB and its accessories including necessory arrangement for fixing on exixting panel etc. as required.
-
-
-
Rotary Handle Extended ROM including drilling slots in cubical panel
1
-
-
Drawing and Approval
-
-
-
Submission of as fitted drawings and SLD of the work in Autocad DWG and PDF format along with physical copy of the same in the format and standard to get the approval from electrical inspectorate.(along with seal,signature and license details) etc as required.