National Institute Of Technology Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 6,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NITC_833463_1Tender No
Engg/EMU/JE3/0012/HV LAB-EEDTender Authority
National Institute Of Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
20 mm
35
-
-
25 mm
20
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 x 2.5 sq. mm
65
-
-
3 x 4 sq. mm
20
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
16
-
-
Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1
-
-
Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
2
-
-
RECESS TYPE LED
-
-
-
Supply and fixing of recess mounting type (square type),1x1or nearest size of 18 W, 1800 lm, 5700K, CRI 80, Efficacy 100 lm/watt, THD 10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -LCTLRNE-18-CDL(1X1)) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site.
4
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
95
-
-
Supplying and fixing 4 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
5
-
-
Supplying and fixing 125A, 16kA, 4 pole (Three pole and Neutral), 415 V, Moulded casing circuit breaker (MCCB) in the existing MCCB DB , complete with connections, testing and commissioning etc, as required.
1
-
-
Supplying and fixing 125A, 415 V TPN switch disconnector fuse unit including suitable HRC fuses in Sheet steel enclosure type FN on existing panel board with suitable type busbar to connect from panel board, complete with connections, testing and commissioning etc, as required.Supply 3 nos of suitable HRC type spare fuses additional. (Lauritz Kudsen L&K FN TPN SDF - 125A in SS Enclosure or equivalent)
1
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Triple pole and neutral
6
-
-
Triple pole
6
-
-
Single pole
5
-
-
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
4
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40A
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way , Double door
1
-
-
Supply of 1.1 kV grade 3.5C x 70 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable as required.
35
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm
30
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
5
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3.5 C X 70 sq. mm (38mm)
2
-
-
Supplying and making end termination of PVC insulated copper conductor 4x10+ 2x6 sqmm submain wiring with suitable size Copper lugs etc as required.
15
-
-
Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required
70
-
-
Supplying and fixing cable details tags using Aluminium sheet of size 10 cm X 3 cm X 2 mm or nearest size on the existing cable.
2
-
-
Supplying and fixing the identification details of cables and Distribution boards details with vinyl stickers on existing panel board/DB/Switch Board etc. as required
11
-
-
Supplying and fixing 3 phase 12 way (6+36), double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 250 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%