National Centre For Earth Science Studies Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

National Centre For Earth Science Studies - NCESS Tender

Works
Building Construction
Eprocure
Opening Date15 Jan 2025
Closing Date17 Feb 2025
Tender Amount₹ 3,04,884 
Notes
Download

Costs

Summary

Room 109 And External Repair Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and applying high performance an emulsified thixotropic Bitumen protective coating two coats (materials available in the market) on mosonry /concrete surfaces (at a coverage rate of 4m2/litre/coat) so as to get a black flexible tough barrier protective film having a DFT of minimum 125microns/coat and properties & ASTM test standards prescribed for the same over a priming coat of same Bitumen emulsion material as per the direction. The primer coat can be made in the site by diluting the same bitumen emulsion with 20% water and applied after cleaning thoroughly of all contaminants and making the surface free from oil, greese, wax, dirt,dust or any other foreign matter which might affect adhesion. The Waterproof coating should be applied in two coats & a Primer Coat to achieve the required thickness. (Total 3 coats including primer coat) Earth Work GF, Cellar part-Avg height = (3.3+0)/2=1.65 LMR1

20

169

3396

... More
Providing and fixing of Self Adhesive black Bituminus /polymeric Felt sheet (available in a size of 1m wide & 20m long rolls) having Silver coloured /type plastic material coated Membrane & Felt sheet of thickness 1.5mm or above with water proofing capacity and fixing the same on surfaces (with necessary overlaps on joints) after removing the sticker already affixed on it and sealing all joints by heating,coving & melting using suitable devices including all cost of materials, labour & Conveyance charges etc. Complete Earth Work GF, Cellar part-Avg height = (3.3+0)/2=1.65 LMR2

20

194

3880

... More
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) in front of Adminis block-dwarf wall Other Area Like A/C Holes, Air Holes, Cellar Portion

0.95

6658

6325.34

... More
(13.7.1) 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) plinth protection- alongside wall, Earth Work GF, Earth Work Cellar. Plastering Portion Damaged by Bobcat

36

361

13006.8

... More
Providing and applying two coats of elastomeric liquid water proofing membrane with resilient acrylic polymers (materials available) on wall surfaces without water dilution (ensuring a coverage rate of 4.2-4.5 m2/ Lit/two coats to achieve a DFT of upto 90-100 microns) over a single priming coat of self-penetrating acrylic white Primer having dilution with water in the ratio 2:1 and spreading at the rate of 8-10 sqm./Lit/coat for superior bonding and hiding. Before applying Priming coat, area must be pressure-washed with water jet having a minimum working pressure of 1400psi to remove all dirts, dust and waste products. Then, cut and open the non-structural hairline cracks less than 0.50mm in width upto 10mm with mechanical cutter and clean, moisten the surface cracks and fill the cracks with 'Crack-X-shrinkfree' crack filler by using a putty-blade. Apply two surface coats after allowing the primer coat is cured for 4-5 hours and keep the surface coat dry for 4-6 hours to achieve the required DFT and allow it be undisturbed for 7 more days to become fully cure. The surface coats should have the following technical properties: a hair line crack bridging upto 1mm; elongation of 100% a per ASTMD 412; tensile strength of 3.5MPa per ASTM D412; adhesion strength of 2MPa as per ASTM D541; The system comes with 5-year waterproofing and 7-year paint performance warrenty from the Company concerned (LMR3)

230

242

55660

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface 13.112.1

230

108

24978

... More
Providing and applying white cement-based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 13.80

58

123

7183.3

... More
13.60.1 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work sqm 137.85

60

137

8271

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work 13.98.1

65

90

5905.25

... More
Taking out, doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq.metres and below

2

118

236.6

... More
15.12.2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area 3 sq. metres and above each 414.55

1

414

414.55

... More
(13.114) Melamine polishing on woodwork (one or more coat) Room No.109

3.7

118

437.9

... More
Providing & fixing decorative high pressure laminated sheet of plain/ wood grain in gloss/ matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S, including cost of adhesive of approved quality.1.5 mm thick Room 109

3.7

890

3295.04

... More
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete, 14.34

1

233

233.1

... More
Painting Steel work with synthetic enamel Paint to give an even shade. one or more coat on old work of approved brand and manufacture 13.99.1

1

86

86.55

... More
(21.1.1.2) for fixed portion- Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):/brFor fixed portion /brPowder coated aluminium (minimum thickness of powder coating 50 micron) Room 109

45

466

20983.5

... More
Providing and fixing glazing in aluminium door, window, ventilator,shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

9.5

1325

12592.73

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

41

564

23156.8

... More
1:5:10 (1 cement: 5 coarse sand(zone-III) : 10 graded stone aggregate 40 mm nominal size) Plinth protection-alongside wall

0.9

6050

5445.14

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground,all complete as per directionWith cement mortar 1:4 (1 cement : 4 fine sand) Out Doors, Other Area Like A/C Holes, Repairs box structures

5

462

2311.5

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall -20mm nominal dia pipes, Map Library Side -FF, Map Library Side -107 room, Map Libray Side -Lab-FF, Map Library Side Cellar -A/c Outlet cellar, Ramp Side - Left side A/c drain outlet FF, Ramp Side-Right Side A/c drain outlet FF, Ramp Side -Right Side A/c drain outlet FF

39

325

12678.9

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction: Internal work - Exposed on wall -40mm nominal dia pipes MAP Library Side - Connecting 20mm Two or more pipes to 40mm and Draining AC water 1m minimum away from Building Ramp Side - Connecting 20mm Two or more pipes to 40mm and Draining AC water 1m minimum away from Building

20

674

13487

... More
Supplying and fixing LED type tube fitting 4 feet long20W on the wall ceiling including providing including connections testing commissioning etc as required

4

350

1400

... More
Supplying and fixing of 300mm sweep wall mountingfan on the wall suitable for operation on 230v,singlephase,50hz AC supply including providing connection testing commissioning etc as required

1

4000

4000

... More
CI @34.55%

1

61737

61737.73



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.