Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

National Centre For Earth Science Studies - NCESS Tender

Works
Building Construction
Eprocure
Opening Date12 Feb 2025
Closing Date12 Mar 2025
Tender Amount₹ 22,69,943 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(15.39.1) Dismantling wooden boardings in lining of walls and partitions, excluding supportingmembers but including stacking within 50 metres lead: Up to 10 mm thick

69

50

3474.15

... More
(15.13.1) Taking outdoors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: of area 3 sq. metres and below

1

118

118.3

... More
(6.34.2) Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in Cement mortar 1:6 (1 cement : 6 Coarse sand)

5.75

7676

44138.73

... More
(6.45.2)Half brick masonry with non modular fly ash bricks of class designation10, conforming to IS :12894, in super structure above plinth and upto floor V levelCement mortar 1 : 4 (1 cement : 4 coarse sand)

1

969

969.65

... More
(21.1.1.2) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions.(Glazing, paneling and dash fasteners to be paid for separately):/brFor fixed portion/brPowder coated aluminium (minimum thickness of powder coating 50 micron)

420

466

195846

... More
(21.1.2.2) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

145

564

81896

... More
(21.2.2) Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. Pre-laminated particle board with decorative lamination on both sides sqm

30

951

28531.5

... More
(21.2.2) & (2631) Providing and fixing 04 mm thick Aluminium Composite Panel, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge. Pre-laminated particle board with decorative lamination on both sides

60

1790

107406.6

... More
(21.3.2)Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

52

1325

68928.6

... More
9.97.3Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm

14

90

1271.2

... More
(9.100.1) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm

14

60

840.7

... More
(od1590/2021_2022) Supplying and fixing Aluminium handle with locking arrangements suitable for aluminium windows (M.Rate)

20

60

1203

... More
Supplying and fixing 300 mm Aluminium aldrop (M.Rate)

7

188

1322.79

... More
od1647/2021_2022 Supplying and fixing I-max hinges

40

126

5060

... More
21.11.1) Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless-steel screws etc. to the side hung windows as per direction complete. 205X19 mm

20

292

5856

... More
(21.13) Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.

7

449

3146.85

... More
(21.15.2) Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50-micron aluminium

20

79

1595

... More
(7059) S/F Aluminium hanging floor door stopper with twin rubber & stopper

7

40

280

... More
(7060) S/F Hydraulic door closer tubular type Aluminium section body each

7

560

3920

... More
(13.1.1) 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)

83

294

24472.55

... More
(13.101.1) Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade: 13.101.1 One or more coats on old work sqm 91.25

110

91

10037.5

... More
(13.83.2) Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colourTwo coats

110

121

13370.5

... More
(13.98.1) Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work

165

90

14990.25

... More
(13.88) Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

235

16

3842.25

... More
(11.21.1.1) Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS: 4457, complete as per the direction. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand) Acid and alkali resistant tile

70

1515

106081.5

... More
(11.21.2.1) Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS: 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on a bed of 12 mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand) Acid and alkali resistant tile

90

1637

147393

... More
(11.49.2) Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately -Size of Tile 600x600 mm (11.42) Deduct for not using 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. sqm 735.30 (Rs. 1537.40 minus Rs.735.30 = Rs.802.10)

40

802

32084

... More
(11.43) Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. sqm 633.60

40

633

25344

... More
(11.47.2) Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm

15

1676

25142.25

... More
(11.48.2) Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction 11.48.2 Size of Tile 600x600 mm sqm (11.50) Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. sqm 11.70 (Rs. 258.65 minus Rs.11.70 = Rs.246.95/-)

215

246

53094.25

... More
(12.52) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed.

92

1591

146436.4

... More
(18.7.) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction (Internal work - Exposed on wall) (a) [18.7.4] : 32 mm nominal dia Pipes

5

500

2504.75

... More
(b) [18.7.5]- 40 mm nominal dia Pipes

5

674

3371.75

... More
(18.8.) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction- Concealed work, including cutting chases and making good the walls etc. (a) (18.8.2) - 20 mm nominal dia Pipes

10

513

5137.5

... More
(b) (18.8.3) - 25 mm nominal dia Pipes

3

626

1878.15

... More
6.47 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction (The payment of RCC band and reinforcement shall be made for seperately).

5.75

6994

40216.36

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) lintel

0.6

10719

6431.58

... More
(5.9.5) Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers

5

608

3041.75

... More
(5.22A.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.

80

89

7172

... More
CI Civil Works @ 34.55%

1

422277

422277.48

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A 1.8.1

5

993

4965

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as requiredGroup B 1.8.2

5

1160

5800

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Group C 1.8.3

32

1445

46240

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1.14.1

90

233

20970

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 1.14.4

120

439

52680

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire 1.14.5

30

570

17100

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire 1.14.9

90

754

67860

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 1.12

150

334

50100

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 1.13

50

537

26850

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 1.17.3

40

95

3800

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.6 x 1.5 sq. mm 1.17.6

60

181

10860

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 1.21.1

40

128

5120

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 1.21.2

40

145

5800

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 1.21.3

20

184

3680

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door 2.5.3

1

12833

12833

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 12 way, Double door 2.3.3

1

2573

2573

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 2.10.1

35

256

8960

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Double pole 2.10.3

10

656

6560

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole and neutral 2.10.5

6

1228

7368

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 2.13.2

1

1034

1034

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 2.12.1

1

435

435

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 2.15.3

1

3188

3188

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. 2.16

8

1169

9352

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required. 2.17

5

1592

7960

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 1.24.1

40

103

4120

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 1.24.3

18

158

2844

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 1.24.4

40

122

4880

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 1.24.5

18

197

3546

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module 1.28.3

18

158

2844

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required12 Module 1.28.6

10

272

2720

... More
Supplying and fixing of 4 feet 20 W LED fitting on the surface of ceiling including providing connections,testing,commissioning etc as required MR

36

500

18000

... More
Dismantling the exisiting old and unserviceable ceiling fan,regulator and lamps including shifiting the same MR

10

171

1710

... More
Supplying and fixing RJ 45 connector with juction box suitable for CAT 6 cable from the exisiting data network including connections testing commissioning etc as required MR

10

462

4620

... More
Supplying fixing telephone socket outlet suitable for connecting the exisiting EPABX system including testing,commissioning etc as required MR

3

195

585

... More
Supplying and fixing changer over arrangement for UPS by pass with 2 nos.63A douple pole MCB type in suitable sheet steel enclosure on the wall change over switch providing including connections testing commissioning etc as required UPS ; MR

1

5940

5940

... More
Supplying and laying Sq 3.5x70 mm size AYFY under ground cable in the following ways including providing including connections testing commissioning etc as required (a) In the exisiting duct MR

10

575

5750

... More
Supplying and laying Sq 3.5x70 mm size AYFY under ground cable in the following ways including providing including connections testing commissioning etc as required.(b) On the surface of wall MR

50

661

33050

... More
Supplying and laying Sq 3.5x70 mm size AYFY under ground cable in the following ways including providing including connections testing commissioning etc as required.© In the exisiting pipe MR

10

591

5910

... More
CI electrical 34.55%

1

139251

139251



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.