National Centre For Earth Science Studies Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

National Centre For Earth Science Studies - NCESS Tender

Works
Housekeeping Services
Eprocure
Opening Date11 Jan 2020
Closing Date10 Feb 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Maintenance Work

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Epoxy flooring i) Preparing the the concrete flooring surface by grinding to remove all laitance, dirt,dust on the sutface of floor by vaccum suction. Any cracks on the floor shall be suitably repaired and construction joints shall be filled with epoxy. Applying a coat of solvent free best quality approved epoxy primer and allowing it to become dry Apply solvent free roller applied epoxy of best quality and approved colour epoxy coating two o0r more coats to 2mm thickness and allow to full cure Allow entire system of to air cure for a period of 24 hours before putting to foot traffic etc including all labour materials and conveyance charges etc as directed by office The thickness of epoxy coating should be measured by using elcometer 500 concrete coating thickness gauged got approved by office

130

118950

915

334785

100435

0.3

... More
Providing and laying 4 X 50sq mm Al Armoured cable

400

180000

450

... More
Laying and fixing of one number PVC insulated and PVC sheated / XLPE power cable of 1.1 KV grade of following size on wall surface as required 4x50 sq mm Al Armoured acble

400

40000

100

... More
7.7.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

400

41600

104

... More
Supplying and making end termination with brass compression gland and Al lugs for following size of PVC insulated and pvc sheathed / XLPE Al conductor cable of 1.1 KV grade as required 4x50mm2 (35mm)

2

664

332

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing spreaders in extisting cubicle panel board including drilling holes in cubicle panel, making connections, etc.as required 80 A 36KA four pole MCCB

1

8200

8200

... More
Supplying and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6way (4+24) double door

1

7744

7744

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, minitaure circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection ,testing and commissioning etc.as required. Single pole 6A

4

648

162

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, minitaure circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection ,testing and commissioning etc.as required. Single pole 16A

17

2924

172

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, minitaure circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection ,testing and commissioning etc.as required. Single pole 25 A

2

364

182

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, minitaure circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection ,testing and commissioning etc.as required. 3 pole MCB 40A

2

1652

826

... More
supplying and fixing 32 A/ 40A 4 pole isolater with surface/consealed type enclosure

3

3600

1200

... More
supplying and fixing 25 A 2 pole isolater with surface /consealed type enclosure

2

1600

800

... More
Supplying and fixing following size/module,box along with modular base & cover plate for modular switches in recess etc as required. 6 module

19

5130

270

... More
Supplying and fixing following size/module,box along with modular base & cover plate for modular switches in recess etc as required. 3 module

2

872

436

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 A wsitch

10

850

85

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6A socket

10

1110

111

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 16 A switch

22

2904

132

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 / 16 A socket

22

3850

175

... More
Supplying and fixing following rating,LED fitting 20W LED fittings (1 x 1 feet round

12

30000

2500

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but with out MCB/RCCB/Isolator) 16 way double door

2

4906

2453

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell piont with 1.5 sq.mm FRLS pvc insulated copper conductor single core cable in surface /recessed steel conduit, with modular switch, modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS pvc insulated copper conductor single core cable etc as required Group C

12

11532

961

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 10 mm2 + 1 x 6 mm2 earth wire

10

3280

328

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 4 mm2 + 1 x 4 mm2 earth wire

15

3000

200

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 2.5 mm2 + 1x2.5mm2 earth wire

75

18675

249

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 1.5 mm2 + 1 x 1.5 mm2 earth wire

30

4380

146

... More
Supplying and fixing following rating, double pole, (single phase and neutal), 240v, residual current circuit breaker (RCCB) having a sensitivity current 30mA in the existing MCB DB complete with connection, testing and commissioninmg etc.as required. 40A

2

4190

2095

... More
Supply 10 SWG Cu bare conductor as earth conductor 800m

70

47600

680

151709

45512

0.3



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.