Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Addition/ Alteration And Special Repairs To Building No P-114 At Ins Dronacharya Under Ge Fort Kochi in Ernakulam, Kerala, with an estimated contract value of Rs. 24,30,000. The bid opening date for this tender is 13-11-2026 and the last date for bid submission is 04-12-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender - Kerala Tender
Opening Date13 Nov 2026
Closing Date4 Dec 2026
Tender Amount₹ 24,30,000
Costs
EMD
₹ 48,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Addition/ Alteration And Special Repairs To Building No P-114 At Ins Dronacharya Under Ge Fort Kochi
Contact
Tender Id
2026_MES_798486_1Tender No
8424/E8_GE_FORT_KOCHITender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material and labour for carefully chipping the edges of existing RCC slab cutouts to expose the aggregate and provide a mechanical key including removal of loose concrete, dust, and cleaning with compressed air. Drilling holes into the existing RCC slab for rebar dowels using a rotary hammer drill, depth shall be minimum 100mm, inserting reinforcement bars and ensuring zero air voids in the epoxy. Application of an Epoxy-based Bonding Agent (old-to-new concrete bridge) to the chipped vertical faces of the existing slab just prior to casting. Supplying and pouring Micro-Concrete or Non-Shrink Concrete to fill the cutout including shuttering/formwork from the underside and finishing top surface complete all as specified and as directed.
1.85
-
-
... More
Supplying, cutting, bending, and placing TMT reinforcement bars (Fe500/Fe550) and tying with GI binding wire including injecting high-strength Pure Epoxy Resin (e.g., Hilti HIT-RE 500 V3 or Fosroc Reebafill) into cleaned holes and Inserting reinforcement bars and ensuring zero air voids in the epoxy complete all as specified and as directed.
50
-
-
... More
Material and labour for preparation for chemical waterproofing treatment as per following specification complete all as specified and as directed by Engr-in-Charge :
(i) Grinding the RCC roof slab surface with mechanical grinder to make the surface even and remove all the undulations, followed by cleaning, washing, removing all dirt/ dust using electrical blower complete all as specified and as directed. (ii) Applying cement slurry coat admixed with SBR Latex as per manufacturer’s instructions over the cleaned surface and providing and laying 45 GSM fibre mesh embedded in cement slurry. (iii) Finishing the depressions using polymerised mortar admixed with SBR Latex.
70
-
-
... More
Material and labour for providing and fixing 150 gsm non-woven Polypropylene geo textile membrane with overlap of minimum 50mm as protective medium before screed concrete works over waterproofing treatment complete all as specified and as directed.
65
-
-
... More
Material and labour for M20 grade Ready mix concrete layer as in screed concrete course laid in panels over roof treatment including necessary formwork and filler boards to maintain proper slope, finished even and smooth without using extra cement complete all as specified and as directed.
3.24
-
-
... More
Material and labour for application of Waterproofing Treatment using Liquid-Applied Pitch-Free Polyurethane Membrane as per following specification complete all as specified and as directed :- (i) Applying one coat of two-component water-dispersible epoxy primer, mixed strictly as per manufacturer's instructions and diluted with double quantity of clean water (1:2 by volume), applied uniformly using a roller at a coverage rate of 8.0 to 10.0 Sqm (diluted mix). The applied primer shall reach tack-free condition before water proofing coating is applied.
(ii) Application of Two coats of Single-component, liquid-applied, pitch-free polyurethane (PU) elastomeric waterproofing membrane (Pitch-Free) of DFT 1.30 mm with a coverage of 2 kg/Sqm, with roller that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane, The second coat should be applied in perpendicular direction to the First coat. Termination to be done on wall extending the coating to min.150mm height above the finished floor level. Notes: (i) Flood Test Prior to placement of screed protection, flood to a minimum depth of 50mm of water for 24 hours. Drains shall be plugged and barriers placed to contain the water. (ii) Item Nos. 3 to 9 shall be executed strictly through approved specialist applicators. The contractor shall submit the manufacturer’s applicator certificate, material purchase invoices, and a legal guarantee certificate prior to payment. Make: Fosroc Nitoproof 600 PF/ Asian Paints (SmartCare PU Magnum)/ Sika (Sikalastic®-591)/ Dr. Fixit (Flexi PU 270(I))/ Bostik (Dampfix PU)
70
-
-
... More
Material and labour for chipping and removing all damaged and de-bonded/spalled concrete and plaster from the roof projections, facia, ceilings, chajja, columns etc manually or mechanically so as to expose the corroded reinforcement bars, complete all as specified and as directed.
10
-
-
... More
Material and labour for application Rust Remover to remove the excess rust on the surface of the reinforcement bars and leave it for one day, The surface to be wiped and cleaned. After 24 hours Anti-corrosion coating of Zinc primer on the reinforcement bars to prevent further corrosion complete all as specified and as directed. Make :-Fosroc/ Asian Paints/ SIKA/ Dr Fixit/ Bostik
10
-
-
... More
Material and labour for application of a coat of epoxy-based bond coat over the entire spalled surface to receive the forthcoming repair mortar and plastering with SBR bonding agent chemical cum cement mortar/concrete modifier modified cement mortar (1:4) to an average thickness of 30-40 mm (applied in two layers not exceeding 20mm each), including the cost of all materials, scaffolding as required complete all as specified and as directed. Make :- Fosroc/ Asian Paints/ SIKA/ Dr Fixit/ Bostik
10
-
-
... More
Dismantling wrought iron or mild steel work as in walls, holdfast / MS angles inserted in walls, & MS Railing etc of any description not otherwise provided for, complete all as specified and as directed.
1
-
-
... More
Material and labour for providing and fixing stainless steel (Grade 316 Marine Grade) railing, balusters, window grills made of hollow tubes & other sections, frame work etc including welding, grinding, buffing, polishing and making curvature (wherever required) with necessary accessories, like bends, decorative cups etc including core cutting for fixing the railing with stainless steel bar hold fast, dash fasteners, nut bolts etc, to the slab, steps, columns, beams, etc with suitable arrangement, complete all as specified and directed. Note: (1) Make and Grade shall be clearly engraved on each sections.
100
-
-
... More
Material and labour for PCC type D-2, 1:4:8, using 40 mm graded stone aggregate as in sub base, mass concrete, filling duct etc. complete all as specified and as directed.
3
-
-
... More
Taking down chowkats or frames not exc. 1.50 Sqm each with shutters (without taking off shutters from the frame) etc. complete all as specified and as directed.
1
-
-
... More
Taking down chowkats or frames exc. 1.5 Sqm and not exc 4.00 sqm each with shutters (without taking off shutters from the frame) etc. complete all as specified and as directed.
12
-
-
... More
Supply and fix factory made Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will be metered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mmx 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware: Touch Lock of zinc alloyed (white powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock.] (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose) Notes: (i) The unit rate quoted by contractor excludes cost of glass and includes wire mesh and all other connected accessories. (ii) Glass shall be measured in respective item of BoQ as supply only.
10
-
-
... More
Providing and fixing factory made uPVC white colour casement (Openable) Door frame with single/double shutter made of extruded profile with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with metal chamber, Frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be metered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild steel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. Notes: (i) The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. (ii) Glass shall be measured in respective item of BoQ as supply only.
10
-
-
... More
Supply only 5 mm thick tinted glass, ordinary quality and glazing not exc 0.50 Sqm each pane for fixing in UPVC doors complete all as specified and as directed.
8
-
-
... More
Supply only 6 mm thick toughened tinted glass, exc 0.50 Sqm each pane for fixing in UPVC doors complete all as specified and as directed.
9.5
-
-
... More
Supply and fix powder coated aluminium coated deco grill of approved colour, design & pattern, with approved standard section fixed to frame with and including frame aluminium frame work hollow, 'H'/ 'F' channels by stainless steel screws complete all as specified and as directed.
75
-
-
... More
Roughening surfaces of old concrete floor/ mosaic floor by chipping, picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed.
70
-
-
... More
Material and labour for PCC type B-1, 1:2:4, using 20 mm graded stone aggregate as in floors, coping, levelling course, for filling hold fast etc. including necessary formwork complete all as specified and as directed.
5
-
-
... More
Material and labour for Vitrified double charged coloured premium tiles 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, and shall be jointed in neat cement slurry and pointed in paste pigment to tile shade etc. over and including 15 mm thick screed bedding layers in cement mortar 1:6 for laying floor finishes tiles etc. complete all as specified and as directed.
70
-
-
... More
All as per item No 25 above but as in skirting/dado including necessary cutting etc over and including 10 mm thick plaster in cement mortar 1:4 on brick or concrete surfaces, for receiving wall tiles complete all as specified and as directed.
7
-
-
... More
Dismantling floor, hearth or skirting/ wall tiling including cement mortar bedding screed and plaster (but not backing), and rubbish off the premises or filling the old ducts, complete all as specified and as directed.
40
-
-
... More
Material and Labour for 12 to15 mm thick Vitrified step tiles size exc 0.09 Sqm and not exc 0.25 of approved makes (Johnson Endura, Durato, Somany, or equivalent) in step treads, risers, skirting, landings, etc. jointed with grey cement slurry and pointed with white cement mixed with matching pigment to match the shade of the tiles, over and including a 15 mm thick screed bedding layer in cement mortar 1:6, complete all as specified and as directed.
40
-
-
... More
Material and labour for machine cut polished Kota stone 16 to 18 mm thick over 10mm thick cement screed bed in cement mortar 1:4 as in skirting laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
5
-
-
... More
Material and labour for rounding to edges of stone slab one edge, such as in steps treads, cooking platforms, and similar situations etc. complete all as specified and as directed.
70.4
-
-
... More
Demolition of Cement concrete (unreinforced) not exc 15 cm thickness (below or above ground floors) complete all as specified and as directed.
3
-
-
... More
Demolition of brick/ concrete block masonry built in cement mortar complete all as specified and as directed.
1
-
-
... More
Material and labour for precast cement concrete 1:3:6, type C0 (using12.50 mm graded stone aggregates) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 for closing door/window openings etc. complete all as specified and as directed.
2
-
-
... More
Material and labour for precast cement concrete 1:3:6, type C0 (using12.50 mm graded stone aggregates) block masonry with solid blocks, not exc. 10 cm in width and setting in cement mortar 1:4 complete all as specified and as directed.
6
-
-
... More
Material and labour for 10 mm thick plastering in cement mortar 1:6, on internal walls, window jambs finished even and smooth w/o using extra cement etc.,complete all as specified and as directed.
10
-
-
... More
Taking down cement plaster of any description on walls including raking out joints, hacking for key scrubbing down with water etc., complete all as specified and as directed.
20
-
-
... More
Material and labour for rendering 15 mm thick in two coats (5 mm thick in cement mortar 1:4 with water proofing compound over 10 mm thick plaster in cement mortar 1:6) on fair faces of brick work or concrete blocks surfaces finished even and smooth without using extra cement, complete all as specified and as directed. (Note- water proofing compound shall be measured and paid separately).
35
-
-
... More
Material and labour for 15 mm thick plastering in cement mortar 1:4, (in two layers 10mm + 5mm) on ceiling and chajja cement finished even and smooth w/o using extra cement etc.,complete all as specified and as directed.
10
-
-
... More
Material and labour for 20 mm thick screed bedding layers in cement mortar 1:4 for laying topping layer of etc. complete all as specified and as directed.
5
-
-
... More
Material and labour for Granite 18 mm thick work (Rounded at edges and polished) in floors, steps treads and risers in one piece, or door cills, platforms, urinal partition etc and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite as approved by GE complete.
5
-
-
... More
Supply and fixing Zebra blinds made of 100% polyester anti-wrinkle, dust-proof fabric weighing not less than 250 gsm (Green guard and RoHS certified), operated with smooth rolling mechanism comprising aluminum alloy top/bottom rail weighing not less than 3.6 kg / 15 ft (4.57 m) length, fitted with durable plastic gear set having internal steel coil spring, continuous loop polyester control chain with 46" (117 cm) drop, and heavy-duty powder coated iron alloy mounting brackets including all standard accessories, fixings, and fastenings complete all as specified and as directed. Note: Payment shall be made on the net clear area of the window opening measured. Makes: Hunter Douglas/ Luxaflex/ Vista Window Coverings/ Mac Blinds/ Marvel Window Coverings/ Tuiss/ HR Johnson
10
-
-
... More
Complete removal of existing treatment by scrapping with steel scrapers, washing, rubbing down complete all as specified and as directed.
559.7
-
-
... More
Material and labour for 1.50 mm thick (in two layers 1mm+0.5mm) cement-based wall care putty on walls etc. complete all as specified and as directed.
190
-
-
... More
Material and labour for application of two coats of distemper Acrylic emulsion on wall surfaces over a coat of interior primer complete all as specified and as directed.
115
-
-
... More
Material and labour for two coats of of distemper acrylic emulsion over ceiling surfaces over a coat of interior primer etc. complete all as specified and as directed.
75
-
-
... More
Material and labour for applying two or more coats of Weather coat premium exterior acrylic anti-fungal emulsion paint having VOC less than 50 g/litre, UV resistance, alkali, fungal, and dirt resistance, of required shade, over and including a priming coat of exterior primer, including filling cracks with crack seal and filling depressions with exterior wall putty, over new and old prepared surfaces complete, all as specified and as directed.
369.7
-
-
... More
Material and labour for spreading a cushioning / bedding layer of stone aggregate 6 to 10 mm size, spread to an average thickness, compacted and levelled to receive interlocking paver blocks, complete all as specified and as directed.
5.9
-
-
... More
Material and labour for 60mm thick factory-made cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, hard standings, drive ways or parking areas etc, finishing and sweeping extra sand, complete all as specified and as directed.
118
-
-
... More
Providing and applying a decorative textured paint finish of approved brand and manufacturer (e.g., Asian Paints, Berger, etc.) on wall surfaces to achieve the desired pattern. The work shall include Cleaning the surface thoroughly to remove dust, loose particles, grease, and fungal growth. Filling cracks, holes, or dents with suitable wall putty and sanding the surface to a smooth, even level before application.
Priming: Applying one coat of approved interior-grade primer compatible with the selected texture system.
Texture Application: Applying the texture material using appropriate tools (trowel, roller, or spray gun) as per the manufacturer’s technical specifications to create the approved design/pattern.
Top Coats: Applying two or more coats of top-coat emulsion/finish in the approved shade and sheen (matte, metallic, or glossy) to provide a uniform, durable, and washable finish
155
-
-
... More
Providing, fabricating, and installing a custom-designed POP ceiling. The work shall include a robust Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. The ceiling is to be finished with 12mm thick high-quality moisture-resistant gypsum board, jointed with fibre tape, and finished with a smooth layer of POP punning to achieve a seamless surface. Creating stepped designs, curved profiles, coves (for concealed lighting), drops, or intricate geometric patterns as per the approved design. Quoted rate shall include all additional framework, specialized corner beads, and labor required to achieve sharp lines and specific profile geometries. The quoted rate shall also include all cutting and framing required to accommodate recessed light fixtures, AC diffusers, speakers, smoke detectors, access trap doors, or other service components including provision of additional supporting framework to ensure structural stability around the openings.
65
-
-
... More
Providing and fixing wall panelling using high-density Wood Plastic Composite (WPC) fluted panels of 15 to 20 mm thick of approved brand (e.g., Rajshri Plastiwoo/, SMP Magma or equivalent) and design (laminated wood design in an approved shade and pattern). The work shall include structural framework consisting of Aluminium box sections or PVC fillets at a maximum spacing of 400mm – 600mm centre-to-centre, as per manufacturer's guidelines to ensure a perfect level and plumb surface complete all as specified and as directed. Note:
Fixing: Installing the WPC panels usingn stainless steel hidden clips/fasteners or high-strength construction adhesive as directed by Engineer in charge and ensuring a secure, long-lasting bond. All joints shall be accurately matched and finished seamlessly. Finishing & Accessories: Providing and fixing matching edge beads, corner profiles, or capping sections to cover edges and corners for a clean, professional finish.
50
-
-
... More
Taking down copper / aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit and making good the disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
71
-
-
... More
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed.
2
-
-
... More
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed.
130
-
-
... More
Taking down old/unserviceable ceiling fan deposited MES store room AGE (E/M) office, complete all as specified and as directed.
7
-
-
... More
Supply and installed Hi wall mounted air-cooled star rated split type air conditioner, electric driven, 230 V, single phase indoor unit, outdoor unit complete with cordless remote-control unit and within built air ioniser, plasma filter, for better indoor air quality with minimum 5-star rating and BEE 5.0 of capacity 2.0TR, complete all as specified and as directed.
1
-
-
... More
Voltage stabilizer of automatic operation, three phase naturally oil cooled indoor, type and designed, for input variation between 170 V to 250 V without voltage stabilized at 230 V accuracy +/- 2.5 % and speed of correction, 8 volt per second and of capacity 5.0 KVA, complete all as specified and as directed.
1
-
-
... More
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB,240 volt, 20 Amps complete all as specified and as directed.
1
-
-
... More
Material and labour for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting wall/PCC, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and as directed for the following :-
-
-
-
... More
One light/ Ceiling fan/controlled by one switch.
29
-
-
... More
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
10
-
-
... More
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
20
-
-
... More
Description all as per item No 59 here in before but using 2.5 sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sqmm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
12
-
-
... More
Supply and fix modular type Fan step regulator, 120W - 2 module all as specified and as directed
4
-
-
... More
Supply and fix Modular switch 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
59
-
-
... More
Supply and fix Modular switch 16 Amp, single pole, one way, 230 Volt complete all as specified & directed.
12
-
-
... More
Supply and fix Modular socket outlet 2 in 1, 3 pin, 06 Amp flush type, 230 volt, complete all as specified and directed
30
-
-
... More
Supply and fix modular socket outlet multipurpose 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, 230 volt, complete all as specified & directed.
12
-
-
... More
Supply and fix ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
29
-
-
... More
Dismantling of existing AC plant duct and removing from building roof/ wall surface, duct made out of GI sheets any gauge size up to 1.5 x 6 m and making good the disturbed wall/ roof surfaces matching with existing surface and surrounding area and shifting to deposite in MES AGE EM OFFICE store yard complete all as specified and as directed.
15
-
-
... More
Supply and fix BLDC ceiling fan of 1200 mm sweep, minimum air delivery 210 cfm ,brushless direct current motor, BEE five star rated, 220 - 240 volts, AC, 50 Hz including wireless remote and hanging with fan hook, down rod up to 05 feet and connecting up with provision of 3 core copper flexible cable of size 1.5 Sqmm from ceiling rose to fan Including safety precaution of steel wire rope thorough connecting with ceiling fan and ceiling fan hook with fan rod complete all specified as directed.
4
-
-
... More
Supply and fix in replacement of surface mounted LED tube light fitting four feet long, 20 Watt with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and as directed.
25
-
-
... More
Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non-metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 4 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note: - Four runs of 4 sqmm cable, two runs of 4 sqmm cable and one run of PVC conduit will be measured as one unit
80
-
-
... More
Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into suitable size of PVC non-metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note: - Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of PVC conduit will be measured as one unit
50
-
-
... More
Supply and fixing in repair of sheet metal enclosure distribution board, triple pole and neutral, vertical type, AC, 415-volt, 04 way with 200 Amp rated copper bus bar and double door complete all as specified and as directed.
1
-
-
... More
MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA rupturing capacity, C-curve type including taking down of existing unserviceable MCCB complete all as specified and as directed.
1
-
-
... More
Supply, lay, test & commissioning of LT UG cable XLPE insulated, sheathed, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable, with aluminium stranded conductor, LT 1100 Volts grade of size 70 sqmm 3.5 core laying in floor/wall/trenches/ducts complete all as specified and as directed.
100
-
-
... More
Supply and fix sheet metal enclosure MCB DB SPN 8-way Vertical type with 200 Amps rated bus bar 230 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed.
4
-
-
... More
Supply and fix MCB SPN 40 to 63 Amp, 240 volts of 10 KA rupturing capacity, C-curve type as outgoing complete with connection testing and commissioning complete all as specified and as directed.
4
-
-
... More
Supply and fix MCB SP 6 to 32 Amp, 240 volts of 10 KA rupturing capacity, C-curve type as outgoing complete with connection testing and commissioning complete all as specified and as directed.
36
-
-
... More
Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm centre to centre both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and as directed.
1
-
-