Mahatma Gandhi University Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 8,300Document Cost
₹ 1,150Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MGU_553439_2Bid Award Id
ViewTender No
UE/DB/E51/2022-2023Tender Authority
Mahatma Gandhi University ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core
cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as
required.Group C
5
-
-
1200 mm 2X20W LED Lamp with box type fixture
30
-
-
Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than
105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor
greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast
Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98,
RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly
accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
mentioning chip manufacturer)
3
-
-
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using
standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC
insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended
original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,
canopies, shackles and blades working on 230V/240V single phase A/C
7
-
-
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
300
-
-
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
80
-
-
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor
cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including
giving necessary connections of the following sizes.1.00 sq.mm 1 Run
30
-
-
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor
cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including
giving necessary connections of the following sizes.1.00 sq.mm 2 Run
20
-
-
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor
cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including
giving necessary connections of the following sizes.1.00 sq.mm 3 Run
25
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
50
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
250
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
20
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
50
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
100
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
30
-
-
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )1 module
moulded plastic box on surface
5
-
-
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )2 module
moulded plastic box on surface
10
-
-
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )3 module
moulded plastic box on surface
5
-
-
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )6 module
moulded plastic box on surface
4
-
-
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )8 module
moulded plastic box on surface
3
-
-
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.1 or 2 Module
15
-
-
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.3 Module
5
-
-
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.6 Module
4
-
-
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.8 Module
3
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required
10
-
-
Supplying and fixing following piano type switch / socket on the existing switch box/ cover including
connections etc. as required.5/6 amps switch
50
-
-
Supplying and fixing following piano type switch / socket on the existing switch box/ cover including
connections etc. as required.15/16 amp switch
15
-
-
Supplying and fixing following piano type switch / socket on the existing switch box/ cover including
connections etc. as required.3 pin 5/6 amp socket outlet
15
-
-
Supplying and fixing following piano type switch / socket on the existing switch box/ cover including
connections etc. as required.6 pin 15/16 amp socket outlet
15
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
20
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
10
-
-
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )32A DP switch with indicator
2
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
15
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
15
-
-
Erection of wall bracket / ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting,
complete with all accessories including connection etc. as required.
15
-
-
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
20
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding
connection etc as required.
20
-
-
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )6A 3 pin plug top
5
-
-
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )16A 3 pin plug top
5
-
-
Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm
FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More
than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
100
-
-
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and
welded to shape and fixing the same to wall / parapet using clamps as noted along with each size,
painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the
damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
5
-
-
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
2
-
-
Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm,
150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat
of red oxide primer as per IS 732 as required.
10
-
-
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting
etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less
shall be ignored)
100
-
-
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including
plastering colour washing etc. as required
5
-
-
Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to
450mm sweep including plastering colour washing etc. as required.
2
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8
way, Double door
1
-
-
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
-
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB
with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
20
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole and netural
1
-
-
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
2
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
Supply, conveyance and fixing the following types & current rated control gears & switchgears
conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as
required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based
release with overload setting of 50 - 100% having adjustable OL & SC
1
-
-
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board
with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as
required.125 Amp TP & N
1
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with
factory made clamp
30
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with
factory made clamp
30
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm
with factory made clamp
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 16 sq. mm (28mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.3 1/2X25 sq.mm (28mm)
2
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
1
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
30
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
60
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
20
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required4.00 mm copper conductor ( 8 SWG)
25
-
-
Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber,
suitable size nut & bolt, providng heat shrink sleeves etc. as required
450
-
-
Supply and providing copper earth bus in the panel board
125
-
-
Supply ,installation, testing, and commissioning of Philips ceiling light (down lighter) 15 watts duraslim or equivalent make. The rate shall be inclusive of all taxes, conveyance and installation etc complete
8
-
-
Supply and providing 20 W LED PVC body single tube (slim) fitting with all accessories and lamp directly on wall/ceiling including giving connections as required
25
-
-
Supply and providing 6w LED bulb in position
10
-
-
Supply and providing 9w LED bulb in position
15
-
-
Supply and providing 12w LED bulb in position
10
-
-
Supply and laying 20mm PVC coreugated flex conduit in position.
30
-
-
Supply and laying 25mm PVC coreugated flex conduit in position.
15
-
-
Supply and installation of 225mm sweep exhaust fan (metal) in the existing opening ,fixing necessary bolts and nuts, making good the damages etc as required including giving connections with required length of PVC sheathed round copper flex wire etc complete
6
-
-
Supply and installation of 450mm sweep exhaust fan (metal) in the existing opening ,fixing necessary bolts and nuts, making good the damages etc as required including giving connections with required length of PVC sheathed round copper flex wire etc complete
8
-
-
Supply and fixing resistance type regulator in the existing switch board including necessary connections etc complete
15
-
-
Supply and fixing 5 in 1 flush type combained plug socket in the existing switch box and giving connections as required
15
-
-
Supply and fixing DP enclosure on wall in position
1
-
-
Supply and fixing FP enclosure on wall in position
1
-
-
Supply and fixing 4 way single pole and neutral, sheet steel ,MCB distribution board,240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar,earth bar, DIN bar, interconnection,powder painted including earthing etc. on wall in position
1
-
-
Supply and providing 40A TP Isolator in the existing MCB DB in position
1
-
-
Supply and providing 63A TP Isolator in the existing MCB DB in position
1
-
-
Supply and fixing copper earth bus on wall, including making holes as required
1
-
-
Supply and providing 19mm or nearest size plywood sutable for fixing 450mm exhaust fan in position
8
-
-
Charges for detecting the faults in the existing wiring system, rectifying the damages, restructuring the system properly etc as required
1
-
-
Charges for restructring and converting the existing wiring system without damages including giving connections etc as required
5
-
-
Charges for dismantling the existing 1.5/2.5/4 sqmm conduit wiring circuit without damages and refixing the same in new position etc as required
50
-
-
Charges for dismantling the old and unserviceable DBs/switch boar/wiring circuits/ fittings etc on wall/ceiling including rough plastering and making good the damages etc complete
1
-
-
Charges for painting with two coat of enamel paint over a coat of epoxy primer after rubbing/cleaning the surface of the existing following old installations, switch boards, DBs, light shades, down rods of fans & fittings etc in the laboratorys
1
-
-
Charges for painting with two coat of enamel paint over a coat of red oxide primer after rubbing/cleaning the surface of the existing following old installations, switch boards, DBs, panel board, light shades, down rods of fans & fittings, etc as required
1
-
-