Local Self Government Department Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Local Self Government Department - LSGD Tender

Works
Electrical and Electronics
Eprocure
Opening Date18 Jan 2025
Closing Soon25 Jan 2025
Tender Amount₹ 2,07,384 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points

1

485

485.47

... More
90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point

1

647

647.3

... More
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

4

1257

5030.6

... More
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

1

178

178.55

... More
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply

1

2212

2212.04

... More
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm

3

207

621.81

... More
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

3

145

435

... More
1.17.16:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.7 x 2.5 sq. mm

8

210

1686

... More
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm

4

151

607.88

... More
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

15

93

1397.7

... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

15

67

1005.45

... More
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

8

296

2369.28

... More
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp

20

202

4048

... More
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm

8

180

1447.12

... More
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp

20

177

3559.4

... More
90.12.5.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm

8

168

1346.88

... More
90.12.7.12:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp

20

180

3601

... More
90.12.5.12:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm

8

170

1363.6

... More
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

2

2060

4121.26

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

9

247

2227.41

... More
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

3

420

1260.3

... More
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

2600

2600.1

... More
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

3

105

317.67

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

7

163

1143.94

... More
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

4

137

550.88

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

7

216

1518.09

... More
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket

1

317

317.55

... More
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator

1

566

566.67

... More
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

3

301

904.29

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

2

331

663.66

... More
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

3

413

1239.63

... More
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

1

475

475.02

... More
OD349866/2024-2025:Supply and execution of Bulk head fitting,IP 66 for pheripheral lighting (Philips, Havells, Bajaj )

2

1203

2406.4

... More
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

7713

7713.78

... More
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

0.5

1058

529.32

... More
OD349870/2024-2025:Earthing with 40 mm dia. medium class GI earth pipe 2 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped &amp;amp; tightly clamped to the pipe using 25x6 mm steel bolt &amp;amp; nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping &amp;amp; bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal &amp;amp; salt as required shall be filled at 30 CM dia .around the earth electrode)

1

4796

4796.83

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

20

64

1287

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

6

27

166.44

... More
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

15

60

908.85

... More
OD349867/2024-2025:Sheet steel DP MCB enclosure

1

502

502.7

... More
OD349868/2024-2025:Supply and crimping of RJ 45 Connector

2

24

49.16

... More
OD349869/2024-2025:"Supply and providing patch chord with CAT 6 UTP 4pair cable min. 2m length."

1

276

276.77

... More
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm

75

101

7584

... More
OD349901/2024-2025:supply and crimping Tubular Copper sockets for 4 sqmm cable

2

9

19.34

... More
OD358222/2024-2025:Supply, installation, testing and commissioning of high wall mounting INVERTER type 5 STAR split air conditioner unit conforming io IS 1391(Part II)(amendments-1 except power consumption norms) fitted with hermetically sealed compressor operating on 230V single phase AC supply, R32/R134/R410 /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc with copper condensing coil,white / off white colour of following capacity, with cordless remote control etc with one year warranty for machine and 3 years for compressor. 1 Tr INVERTER type 5 star single phase split AC unit including Cu pipe connection &amp; electric cabling from indoor to outdoor unit upto 3m (O General/Daikin/Voltas/Blue Star )

1

40757

40757.19

... More
OD358220/2024-2025:Supply of 4 KVA automatic voltage stabilizer for A/C unit with input voltage 170 - 270 V and output 210 -230 V with overload protection (cut off), time delay, indicator, chord wire etc., as required.

1

3506

3506.57

... More
OD358221/2024-2025:Supply and installation of out door unit stand for single/three phase wall mounting split AC unit as required-

1

1154

1154.07

... More
OD358813/2024-2025:Supply and providing 3KVA 48Volt. On-Line UPS INPUT CAPACITY 3000VA/3000W VOLTAGE 220/230/240 VAC BATTERY VOLTAGE 48V BATTERY TYPE Lithium-ion or Lead Acid Battery (24V 180 AH 2 nos) FLOATING CHARGE VOLTAGE 52 VDC (Configurable up to 58 VDC From LCD) OVERCHARGE PROTECTION 60 VDC CHARGING CURRENT (MAX.) 60 A (Configurable 10A / 20A / 30A / 40A / 50A / 60A From LCD) INDICATION LCD PANEL Load Leval, Battery Leval, AC Mode, Battery Mode, Bypass Mode and Fault Indicator Via LCD ALARM BATTERY MODE : Sounding every 5sec LOW BATTERY: Sounding every 2 Sec. OVERLOAD: sounding every Sec. FAULT: Continousl VOLTAGE RANGE 110-280 VAC@50%Load ; 176-280 VAC@100% Load PHASE SINGLE PHASE WITH GROUND FREQUENCY RANGE 46Hz - 54Hz or 56Hz - 64Hz POWER FACTOR >0.98 @ NOMINAL VOLTAGE (100% LOAD) INPUT CURRENT HARMONIC DISTORTION THD(i) >8% OUTPUT OUTPUT NOMINAL VOLTAGE 220/230/240 VAC AC VOLTAGE REGULATION +1% (BATTERY MODE) FREQUENCY RANGE Synchronized Range: 50Hz System: 47-53Hz / 60Hz System: 57-63Hz Battery Mode: 50Hz+0.1^ or 60 Hz+0.1% CURRENT CREST RATIO 3:1 (Max) HARMONIC DISTORTION < 3% THD (Linear Load) :< 5% THD (Non-Linear Load) AC/DC TRANSFER TIME ZERO INVERTER to BYPASS TRANSFER TIME 4ms (Typical) WAVE FORM Pure Sine Wave on AC Input Power Mode & 54 VDC on Battery Mode ON FULL CHARGED BATTERY EFFICIENCY LINE MODE : 95% / ECO MODE: 99.5% / BATTERY MODE: 92.0% (MAX Life, HYCON,APC, HYKON make )

1

78463

78463.51



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.