Local Self Government Department Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Local Self Government Department - LSGD Tender

Works
Electrical and Electronics
Eprocure
Opening Date20 Jan 2025
Closing Date29 Jan 2025
Tender Amount₹ 4,11,781 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.15.4.2 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

6

-

-

... More
MROD Supply and Fixing of Wall Lamp with top and Bottom Projection of Light

20

-

-

... More
90.15.4.5 Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

2

-

-

... More
90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.3 core 1.50 sq mm

50

-

-

... More
Supply, installation, testing and commisioning of Modular Contactor 25A, 240V

1

-

-

... More
90.12.5.15 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 16 sq mm

20

-

-

... More
90.12.5.1 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm

100

-

-

... More
9.1.8 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

8

-

-

... More
90.12.10.2 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

100

-

-

... More
1.17.30Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x6 sq. mm

10

-

-

... More
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

135

-

-

... More
1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch

2

-

-

... More
1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet

2

-

-

... More
1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

2

-

-

... More
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

-

-

... More
2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. asrequired.Single pole

12

-

-

... More
Supply and installation of Hensel make IP 65 terminal junction box for termination 1.50 sq.mm 3 core cable for street light post

16

-

-

... More
2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

4

-

-

... More
2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps

1

-

-

... More
2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.40 amps

1

-

-

... More
od1762283/2022_2023 Supply and fixing Astrononical time switch suitable for 1 output per phase and suitable for single phase supply including necessary connections as required.

1

-

-

... More
5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired.

1

-

-

... More
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C

3

-

-

... More
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

10

-

-

... More
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

10

-

-

... More
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

15

-

-

... More
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

2

-

-

... More
90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assemblyas per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approveddesign and requirement, with front and rear access facility, bus bar chambers, hingeddoors for all switch gear compartments, earthing the doors using 4 sq mm braidedcopper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamberand cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted anglesetc shall not be used for the fabrication of panel assembly. The measurments will betaken the area of the complete sheets used for panel board including partitions,folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

1

-

-

... More
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG)

50

-

-

... More
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

5

-

-

... More
90.16.5.1 Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.00 mm (14 SWG)

50

-

-

... More
90.16.5.3 Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)

4

-

-

... More
OD356656/2022-2023 Supply and providing iron hook for binding service wire

1

-

-

... More
OD356657/2022-2023 Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base inthe existing meter board and giving connections etc.

1

-

-

... More
OD356658/2022-2023 Supply and fixing 32A backelite fuse base with HRC fuse link in the existing meterboard and givingconnections etc

1

-

-

... More
14.1 Excavation for foundation in soft soil including dressing of sides and ramming ofbottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.

2

-

-

... More
14.7Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.

2

-

-

... More
OD396536/2022-2023 Supply and fixing 110 Watts MIXER AMPLIFIER WITH BUILT-IN DIGITAL PLAYER , ,FM with USB reader and SD/MMC card reader facility. having 6 Mic & 2 Aux Input 110W power output ,75W RMS

1

-

-

... More
MR(OD) Supply and Installation of 98dB/1W/1m, 114dB/40W/1m PA Music Horn Speaker

3

-

-

... More
1.17.2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm

140

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.