Local Self Government Department Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 19,288Document Cost
₹ 1,705Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_LSGD_737869_1Bid Award Id
ViewTender No
LSGD/CELSGD/96918/2024-2025Tender Authority
Local Self Government Department ViewPurchaser Address
-Website
http://https://lsgkerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
OD391889/2024-2025:Engaging plumber for the Maintenance of plumbing works
2
-
-
... More
OD391890/2024-2025:Engaging man for cleaning the existing pond, removal of rubbish up to a distance of 50 m outside the pheriphary of the area cleaned as per DLR statement
6
-
-
... More
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
8
-
-
... More
OD391895/2024-2025: Supplying and fixing RCC ring 1.00 m dia Excluding earth work excavation filling the sides including all charges
2
-
-
... More
Choorakettan Anganawadi centre no 64
-
-
-
... More
OD391891/2024-2025:Supplying and fixing 40mm dia 8kg/cm2 HDPE pipe PE-80 including special and fitting charge but excluding trenching and refilling etc. complete.
55
-
-
... More
OD391892/2024-2025:Engaging plumber for the Maintenance of plumbing works
2
-
-
... More
OD391893/2024-2025: Supplying and fixing RCC ring 1.00 m dia Excluding earth work excavation filling the sides including all charges
2
-
-
... More
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
8
-
-
... More
OD391894/2024-2025:Engaging man for cleaning the existing pond, removal of rubbish up to a distance of 50 m outside the pheriphary of the area cleaned as per DLR statement
5
-
-
... More
OD404821/2024-2025:Supplying and fixing 1.5HP Bore well submersible pumps 13-15 stage (single phase)(head range 40-120 m)
1
-
-
... More
Chattuparakudy Anganawady centre no 73
-
-
-
... More
OD391897/2024-2025:Engaging plumber for the Maintenance of plumbing works
2
-
-
... More
OD405052/2024-2025:Supplying and fixing 50mm dia 10kg/cm2 HDPE pipe PE-80 including special and fitting charge but excluding trenching and refilling etc. complete.
575
-
-
... More
OD391898/2024-2025:Engaging man for cleaning the existing pond, removal of rubbish up to a distance of 50 m outside the pheriphary of the area cleaned as per DLR statement
5
-
-
... More
chinnaparakudy anganawady centre no 76
-
-
-
... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
56.77
-
-
... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
56.77
-
-
... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.96
-
-
... More
OD398169/2024-2025:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
3.84
-
-
... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
1.28
-
-
... More
5.7:Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
8.65
-
-
... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.27
-
-
... More
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
86.48
-
-
... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
605.36
-
-
... More
OD398294/2024-2025:Supplying and fixing 40mm dia 8kg/cm2 HDPE pipe PE-80 including special and fitting charge but excluding trenching and refilling etc. complete.
250
-
-
... More
OD403864/2024-2025:Supplying and fixing 1.5HP Bore well submersible pumps 13-15 stage (single phase)(head range 40-120 m)
1
-
-
... More
Centre no 78 korangatti anganawady
-
-
-
... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
9.42
-
-
... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
14.13
-
-
... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.38
-
-
... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
0.51
-
-
... More
5.7:Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
2.29
-
-
... More
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
30.52
-
-
... More
OD404703/2024-2025:Supplying and fixing 40mm dia 10kg/cm2 HDPE pipe PE-80 including special and fitting charge but excluding trenching and refilling etc. complete.
20
-
-
... More
OD404745/2024-2025:Supplying and fixing Monoblock Pump (1.5 HP), Multicolour. 4.1 out of 5 stars .(single phase)
1
-
-
... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
190.4
-
-
... More
10.25.2:Item Shifted to Sub head 14 as item 14.73
Item Shifted to head 14 as item 14.74
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
26.4
-
-
... More
OD405087/2024-2025:providing and fixing expanded metal mesh of size 25*25mm and strands 3.25 mm wide 1.6 mm thick for encasing or steel sections excluding cost of hangers.
1.77
-
-
... More
Centre no 79 Thalamali anganawadi
-
-
-
... More
OD405046/2024-2025:Supplying and fixing 50mm dia 8kg/cm2 HDPE pipe PE-80 including special and fitting charge but excluding trenching and refilling etc. complete.
310
-
-
... More
OD405074/2024-2025:Engaging plumber for the Maintenance of plumbing works
2
-
-
... More
OD405075/2024-2025:Engaging man for cleaning the existing pond, removal of rubbish up to a distance of 50 m outside the pheriphary of the area cleaned as per DLR statement
4
-
-
... More
plumbing
-
-
-
... More
50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
25
-
-
... More
50.18.9.14.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
20
-
-
... More
50.18.9.15.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall
15
-
-
Evaluation Notes How It Works ?