Kochi Metro Rail Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kochi Metro Rail Limited - KMRL Tender

Works
Consultancy Services
Eprocure
Opening Date14 Mar 2019
Closing Date17 Apr 2019
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and laying at the site of work of 11 KV (E) stranded compacted Circular Aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting compounded, with copper tape over each core, core laid up, FR PVC inner sheathed, galvanised steel flat strip armoured and overall FR PVC sheathed cable conforming to IS: 7098/ part II/ 2011 with upto date amendment and to be laid in existing RCC cable trench / or through pipe as required / approved by utility owing agency, testing and commissioning of cable as required as per standards and direction of engineer in charge of the following cables.70 sq.mm ( Three Core)

600

-

-

... More
S/E of heat shrinkable cable end termination for 11KV / 6.6 KV Earthed XLPE including mounting clamps.

-

-

-

... More
Supply & making, testing and commissioning of complete heat shrinkable type indoor/ outdoor type cable end terminations / jointing as specified in the specification including provision of laying, dressing, tagging, glanding with lugs/ ferrules for termination of HT XLPE insulated cables including making holes in the switch board, clamping, supporting complete as required by the utility owing agency for following size of 3 Core XLPE aluminium conductor of 11 KV grade as per standards and directions of the engineer in charge. Additional loop of cable shall be made before end termination in the ground / cable trench. Heat shrinkable cable size 70 sq.mm (out door Type)

20

-

-

... More
Supply & making, testing and commissioning of complete heat shrinkable type indoor/ outdoor type cable end terminations / jointing as specified in the specification including provision of laying, dressing, tagging, glanding with lugs/ ferrules for termination of HT XLPE insulated cables including making holes in the switch board, clamping, supporting complete as required by the utility owing agency for following size of 3 Core XLPE aluminium conductor of 11 KV grade as per standards and directions of the engineer in charge. Additional loop of cable shall be made before end termination in the ground / cable trench. Heat shrinkable cable size 120 sq.mm (out door Type)

46

-

-

... More
Supply & making, testing and commissioning of complete heat shrinkable type indoor/ outdoor type cable end terminations / jointing as specified in the specification including provision of laying, dressing, tagging, glanding with lugs/ ferrules for termination of HT XLPE insulated cables including making holes in the switch board, clamping, supporting complete as required by the utility owing agency for following size of 3 Core XLPE aluminium conductor of 11 KV grade as per standards and directions of the engineer in charge. Additional loop of cable shall be made before end termination in the ground / cable trench. Heat shrinkable cable size 300 sq.mm (out door Type)

672

-

-

... More
Supply & making, testing and commissioning of complete heat shrinkable type indoor/ outdoor type cable end terminations / jointing as specified in the specification including provision of laying, dressing, tagging, glanding with lugs/ ferrules for termination of HT XLPE insulated cables including making holes in the switch board, clamping, supporting complete as required by the utility owing agency for following size of 3 Core XLPE aluminium conductor of 11 KV grade as per standards and directions of the engineer in charge. Additional loop of cable shall be made before end termination in the ground / cable trench. Heat shrinkable cable size 300 sq.mm (straight through joint)

50

-

-

... More
POLES & STRUCTURES

-

-

-

... More
Supply and fixing of double pole structure for 11/0.4KV substation with 9 Mtr PSC poles, channel cross arms 3Mtr,DO fuse,11 KV lightening arresters ,AB switch, earthing etc complete in all respects as per KSEB specification.

2

-

-

... More
Nylon Cable ties 300mm length x 2.8 mm thick Packet- The unit specified in packet having minimum 100 nos of cable ties

500

-

-

... More
COMPACT SUBSTATION (CSS)

-

-

-

... More
COMPACT SUBSTATION:Design, Engineering, Manufacturing, Transportation, installation, Testing, Supply of 11KV Outdoor Non Extensible 500 KVA Compact substation (CSS) with 2 nos. of motorised load break switch 630 A, 21 KA for 3 sec, 1 no. VCB, with 400 A 21KA for 3 sec ,500 KVA Dry Type resin cast transformer and LV side Draw out type ACB -1000 A, Fixed type outgoing type 400Amps 433V 36KA 4P Fixed Manual Moulded Case Circuit Breaker with numerical release (Make: ABB/L&T/SEIL/SEIMENS/ Equivalent) MCCB(400 A x5 Nos, 100 AX1 no). Electronic trip circuit , LT bus- 1000 A, Ics=36 KA, with built in FRTU with compatible for integration with KSEB SCADA system with remote control complete in all respects. The CSS enclosure shall be suitable for placement near sea shore at 50 deg ambient temperature. The CSS shall be from Original Equipment manufacturers of RMU and LV Equipment.

23

-

-

... More
RING MAIN UNIT WITH INTEGRAL FRTU AND FAULT PASSAGE INDICATOR, METERING CUBICLE, AUXILIARY TRANSFORMER FOR LT SUPPLY, GSM MODEM FOR CUSTOMISED COMPACT SUBSTATION AND 11 KV DISTRIBUTION

-

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge.3 way RMU - Ring Main Unit with integral FRTU and VCB - CTC (E) ( cable - Transformer - cable)

40

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. Ring Main Unit with integral FRTU and VCB - CCC(E) ( cable - Transformer cable)

9

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. Installation of Data Acquisition compatible extensible add - on type Ring Main Unit without VCB - C - Extension (FRTU not applicable for this item)

4

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. Installation of extensible add - on type Ring Main Unit with VCB ( Single Switch T Extension) ( FRTU is not applicable for this item)

1

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge.11 KV out door extensible RMU with three load break switch (CCCT) with integral FRTU

16

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge.11 KV out door extensible RMU (CT) with integral FRTU

7

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. 11 KV Ring Main Unit with VCB - CCCC(E) with integral FRTU

5

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. 11 KV Ring Main Unit with VCB - CCTTC(E) with integral FRTU

5

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. 11 KV Ring Main Unit with VCB - CCCCT with integral FRTU

7

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. 11 KV Ring Main Unit with VCB - CCCCTT with integral FRTU

1

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. 11 KV Ring Main Unit with VCB - CCCCCT with integral FRTU

4

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. 11 KV Ring Main Unit with VCB - CCCCCTT with integral FRTU

1

-

-

... More
Supply, erection, testing and commissioning of out door extensible type Ring Main Unit with the following for replacing tapping the DP structure of HT circuits, and on RCC 1:2:4 foundations using foundation bolts and including cost of terminations etc. complete including cost of all materials and labour as per standards and as per the directions of engineer in charge. 11 KV Ring Main Unit with VCB - CCCCC with integral FRTU

3

-

-

... More
TRANSFORMER FOR CUSTOMISED COMPACT SUBSTATION

-

-

-

... More
3 phase 500 KVA 11/0.433 KV AN cooled, vector group DYN-11 Copper wound dry type distribution transformer - with off load tap changer with LT side bimetallic connectors cast out of aluminium alloy as per specifications. with transformer tapping's from +5% to -10% in steps of 2.5 % operatable on off circuit , with HV cable box suitable for 3CX300 sq.mm XLPE cable and LV cable box suitable for 3 runs of PVCA cable with WTI and all other standard fittings conforming to IS- 2026/77 and IS - 1117/1985 revised class of insulation F.

17

-

-

... More
AIR CIRCUIT BREAKERS AT LV SIDE OF CUSTOMISED COMPACT SUBSTATION

-

-

-

... More
Supply installation testing and commissioning of fixed /draw out type 3 pole Air Circuit Breaker conforming to IS 13947 / IEC 60947 P-2 existing LT panel suitable for LT installation 440 V, 50 HZ and having adjustable short circuit, earth fault and over load microprocessor release with LCD display, bar graph and separate LED indication for each type of fault, at least 4 No & 4 NC auxiliary contact safety shutter and fault position acknowledgement mechanism type, ACB shall have separate indication for service, test, isolation, maintenance position including making connection etc. as required Air circuit-breaker electrically operated (electrical draw out type), 4 pole, 1000 amp, 415 volts complete manual spring charged.

17

-

-

... More
433V 36KA 4P Fixed Manual MCCB AT LV SIDE OF CUSTOMISED SUSBTATION

-

-

-

... More
Supply installation testing and commissioning of 4 Nos of 400Amps and 1 no.100 A, 433V 36KA 4P Fixed Manual Moulded Case Circuit Breaker with numerical release (Make: ABB/L&T/SEIL/SEIMENS/ Equivalent) at the outgoing in each Customised Compact Substation.

17

-

-

... More
CABLE SUPPORT ARRANGEMENT IN CABLE TRENCH

-

-

-

... More
Supply, installation of cable supporting arrangement in cable trench with materials such as MS support plate, hook, pipes, angles, anchor bolts etc complete in all respect as per the tender drawing attached for cable support arrangement.

11000

-

-

... More
ENCLOSURE OF ACB & MCCB

-

-

-

... More
Fabrication and supply and installation of out door type with hood, floor mounting, cubicle, free standing, with IP 55 class protection, dust and vermin proof panel boards fabricated out of 14 SWG CRCA sheet including enclosure, aluminium busbar, interconnections, supports, gaskets, sleeves, wiring, earthing, painting ( powder coating and seven tank process) etc. but excluding all electrical components as per requirement suitable for item 7.01 and 8.01 including indication lamps as required.

17

-

-

... More
FRTU INTEGRATION WITH EXISTING SCADA SYSTEM OF KSEB AND INTEGRATED COMMAND AND CONTROL CENTRE OF KOCHI SMART CITY

-

-

-

... More
Supply, installation and testing and commissioning of all hardwares and softwares for integration of FRTUs with existing SCADA system of KSEBL and also integration with Integrated Command and Control Centre of CSML ( The item cost sjhall be excluding FRTU cost which is already covered in RMU and CSS cost).

1

-

-

... More
GIS Mapping carried out DGPS GIS Survey and mapping of newly installed electrical equipments under the scope of supply of bidder using latest GPS technology and equipments

1

-

-

... More
UN INTERRUPTIBLE POWER SUPPLY

-

-

-

... More
Providing, installation, testing and commissioning of UPS, 3Phase 415 V, 50 Hz with 60 min back up Ni+Cd battery bank.One KVA

2

-

-

... More
TRANSFORMER Supply, Installation, Testing and commissioning of Aluminium wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories like, conservator, Silica gel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain/ Flanged Rollers, Earthing terminal, Air release plug. Off load tap changer (+5% to -10% in steps of 2.5%), winding / Top oil temperature rise of 45°C/40°C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc. having max. total losses as per energy efficiency level - 2 at basic Insulation level conforming to IS 2026 (Part- I to Part - II), latest amended and IS 1180 Part-I : 2014 BEE star level - I as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating

-

-

-

... More
Supply and erection of 200 KVA 11KV/433 volt 3 phase 50 Hz distribution transformer

2

-

-

... More
COMPACT DISTRIBUTION FEEDER PILLARS

-

-

-

... More
Supply, installation, testing and commissioning of floor mounted Compact Feeder Pillar ( Main) 440 Volt, 50 Hz, short circuit current 50 KA for 1 sec, made of Mild Steel enclosure with ingress protection IP 54 as per drawings attached. The feeder pillar shall have provision for installing smart meters as per technical specifications. Feeder pillar - Main Feeder Pillar ( OUT DOOR) with Incoming: 2 nos X630 amp, outgoing: 4nos 400A with facility for providing Smart Meters for incoming and outgoing . Vertical SFU for incoming and outgoing as per specification, one set of phase indicating lamps with control MCB.

66

-

-

... More
Supply, installation, testing and commissioning of floor mounted Compact service Feeder Pillar 440 Volt, 50 Hz, short circuit current 50 KA for 1 sec, made of Mild Steel enclosure with ingress protection IP 54 as per drawings attached. The feeder pillar shall have provision for installing smart meters for outgoings as per technical specifications. The service Feeder pillar shall be connected from Main Feeder Pillar . INCOMING: 2X400 amp Vertical SFU outgoing 8nos of 3 phases or 24 nos sngle phases. 32-160 amp Vertical SFU as per specification. One set of phase indicating lamps with control MCB.

132

-

-

... More
LT CABLE - Supply & laying at site work of LT , XLPE insulated, armoured Aluminium conductor cable as per IS 7098/part -I/ 1988 with upto date amendment & specified in the specification of the sizes given below, laying cables in HDPE pipes / RCC cable trenches in all areas, all type of soil/ foot path, road etc. by excavation at required depth and refilling as required / approved by utility , including testing and commissioning of cables as per standards and direction by the engineer in charge.

-

-

-

... More
Aluminium conductor XLPE /PVC insulated PVC sheathed armoured and served cable working voltage 1100 Volt grade 10 sq.mm ( 2 core)

17000

-

-

... More
XLPE/PVC insulated PVC sheathed aluminium conductor unarmoured cable working voltage 1100 volts grade 16sq.mm (4 core)

15000

-

-

... More
Aluminium conductor XLPE /PVC insulated PVC sheathed armoured and served cable working voltage 1100 Volt grade 35 sq.mm ( 4 core)

4000

-

-

... More
Aluminium conductor XLPE /PVC insulated PVC sheathed armoured and served cable working voltage 1100 Volt grade 70 sq.mm ( 3.5 core)

12000

-

-

... More
Aluminium conductor XLPE /PVC insulated PVC sheathed armoured and served cable working voltage 1100 Volt grade 120 sq.mm ( 3.5 core)

6000

-

-

... More
Aluminium conductor XLPE /PVC insulated PVC sheathed armoured and served cable working voltage 1100 Volt grade 185 sq.mm (3. 5 core)

32000

-

-

... More
Providing and laying XLPE/PVC insulated & PVC sheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavation of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and second class bricks covering, backfilling & compaction

-

-

-

... More
4 Core 1.5 sq.mm

1000

-

-

... More
10 core 1 .5 sq.mm

500

-

-

... More
14 core 1.5 sq.mm

500

-

-

... More
END TERMINATION KIT FOR 1.1KV LT CABLE-Supply and making end termination with brass compression gland and aluminium lugs for the following size of PVC insulated and PVC sheathed/ XLPE Aluminium Conductor cable of 1.1 KV grade as Required including cable support clamps

-

-

-

... More
Glanding & termination for 3.5 Cx 185 Sq.mm

700

-

-

... More
Glanding & termination for 3.5 Cx 120 Sq.mm

480

-

-

... More
Glanding & termination for 3.5 Cx 70 Sq.mm

970

-

-

... More
Glanding & termination for 4 Cx 35 Sq.mm

270

-

-

... More
Glanding & termination for 4 Cx 16 Sq.mm

1260

-

-

... More
Glanding & termination for 2 Cx 10 Sq.mm cable

1100

-

-

... More
Glanding and termination of 4 Core 1.5 sq.mm armoured copper control cable

150

-

-

... More
glanding and termination of 10 core 1.5 sq.mm armoured copper control cable

100

-

-

... More
Glanding and termination of 14 core 1.5 sq.mm armoured copper control cable

100

-

-

... More
Termination with al. socket for 1CX50 sq.mm LT XLPE Aluminium un armoured cable

600

-

-

... More
Termination with al. socket for1CX95 sq.mm LT XLPE Aluminium un armoured cable

600

-

-

... More
Termination with al. socket for 1CX185 sq.mm LT XLPE Aluminium un armoured cable

600

-

-

... More
CABLE JOINT FOR 1.1KV LT CABLE-Supply and Erection of LT straight through joint kit/ termination for 1.1 KV grade PVC/XLPE cable as desired by the engineer in charge

-

-

-

... More
Straight through joint kit for cable size 3.5 core 120 - 150 sq.mm

60

-

-

... More
Straight through joint kit for cable size 3.5 core 185 sq.mm

70

-

-

... More
SMART METERING SYSTEM-Design, manufacturing, testing, supply and delivery of AC whole current single phase and three phase Smart Energy Meter with bidirectional communication facility. The meter is suitable for Advanced metering Infrastructure (AMI), Peak Load management (PLM) including Demand Response. The meter have inbuilt GPRS modem for two way communicate with MDAS/Head End System and other required hardwares and softwares equipments as per the requirement of KSEB and as per attached technical specifications. The smart meters shall be installed at the feederpillars outgoings / at the customer premises on case to case basis

-

-

-

... More
Single phase whole current Smart Meter

15000

-

-

... More
Three Phase whole current Smart Meter

8000

-

-

... More
Three phase CT operated Smart Meter

3000

-

-

... More
Suplly and installation of head end system (HES) software for smart meters and the deployment in the cloud

1

-

-

... More
O&M cost of smart meter, communication with head end system (HES) for 5 years. The item cost shall include the communication charges payable to the network service provided for 5 years

1

-

-

... More
Integration of head and system (HES) for smart meter with MDAS / MDMS system of KSEB

1

-

-

... More
WARNING TAPE & ROUTE MARKER

-

-

-

... More
Supply and providing PVC warning tape 150 mm wide and 100 micron thick below ground but above the cables as required.

8000

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required.

50

-

-

... More
CABLE TRAYS-Supply , Installing following size of perforated Hot Dipped galvanised Iron cable tray ( galvanisation thickness shall not be less than 50 microns) with perforations not more than 17.5%, in convenient sectioned joined with connectors, suspended from ceiling with GI suspenders including GI bolts & nut bolts etc. as required .

-

-

-

... More
450X50x2 mm thickness

100

-

-

... More
300X50x1.6 mm thickness

150

-

-

... More
225X50X1.6 mm thickness

150

-

-

... More
CABLE TRAYS-Supply , Installing following size of perforated Hot Dipped galvanised Iron cable tray "bends"( galvanisation thickness shall not be less than 50 microns) with perforations not more than 17.5%, in convenient sectioned joined with connectors, suspended from ceiling with GI suspenders including GI bolts & nut bolts etc. as required .

-

-

-

... More
450X50x2 mm thickness

20

-

-

... More
300X50x1.6 mm thickness

20

-

-

... More
225X50X1.6 mm thickness

20

-

-

... More
CABLE TRAYS-Supply , Installing following size of perforated Hot Dipped galvanised Iron cable tray "TEE"( galvanisation thickness shall not be less than 50 microns) with perforations not more than 17.5%, in convenient sectioned joined with connectors, suspended from ceiling with GI suspenders including GI bolts & nut bolts etc. as required .

-

-

-

... More
450X50x2 mm thickness

20

-

-

... More
300X50x1.6 mm thickness

20

-

-

... More
225X50X1.6 mm thickness

20

-

-

... More
EARTHING SYSTEM-Supply, installation, testing and commissioning of Copper bonded earth electrode made from low carbon steel. Earth rods and molecularly bonded with 99.9 % pure electrolytic copper 250 micron thick and earth pit chambers (poly propylene grade 5 ) 300 mmx300 mm as per the requirement of utility and as per the technical specifications and standards of the following

-

-

-

... More
Supply of copper bonded rod of size (25 mm dia x3000mm long ) with chemical bag of 60 kg. with all accessories. Approximate weight of copper electrode is 5.62 kg. The Item cost including excavation of earth bit

570

-

-

... More
Supply of copper bonded rod of size (17.2 mm dia x3000mm long ) with chemical bag of 60 kg. with all accessories. Approximate weight of copper electrode is 5.62 kg. The Item cost including excavation of earth bit

220

-

-

... More
Copper bonded earth Strip of Size (50x6)mm

2500

-

-

... More
Copper bonded earth Strip of Size (25x4)mm

1800

-

-

... More
supplying and laying 25mmX5 mm GI strip at 05 meter below the ground as strip earth electrode, including connection, terminating with nut bolts, spring, washer etc. as required. Jointing shall be done by overlapping and with 2 sets of GI nuts, bolts& spring washer spaced at 50 mm.

2000

-

-

... More
supplying and laying 6 SWG GI wire at 05 meter below the ground for conductor earth connection/ termination with GI thimbles etc. as required.

2000

-

-

... More
1CX50 sq.mm LT XLPE Aluminium un armoured cable

500

-

-

... More
1CX95 sq.mm LT XLPE Aluminium un armoured cable

500

-

-

... More
1CX185 sq.mm LT XLPE Aluminium un armoured cable

500

-

-

... More
MISCELLANEOUS

-

-

-

... More
Supply, installation at site LT/HT/RSJ/PSC/RCC poles with fittings including cross arms and insulators, cable looping, stay and including all materials.

40

-

-

... More
Supply, one A pole ( painted MS) at site of required height including digging foundation, bac filling the pit as per standard and as per the instruction of engineer in charge.

25

-

-

... More
Supply of HT PSC pole at site as required height including foundation and back filling pit as per standards and instruction of engineer in charge.

20

-

-

... More
Fitting and erecting one HT "A" pole /PSC pole in position including fitting cross arms ( taken from the dismantled items) digging and back filling pit, providing stay as per the instruction of engineer in charge.

20

-

-

... More
Fitting and erecting one pole /PSC pole in position including fitting cross arms ( taken from the dismantled items) digging and back filling pit, providing stay, drawing earth leads etc.

20

-

-

... More
Stringing and shackling, fitting cross arms, insulators and binding, giving jumper connections etc. using ACSR Rabbit conductor for phase and ACSR weasel for neutral, LT 3 phase 4 wire line including cutting and removing tree branches where ever necessary and conveyance of all materials from stacking place.

6

-

-

... More
Stringing and shackling, fitting cross arms, insulators and binding, giving jumper connections etc. using ACSR Rabbit conductor for phase HT 3 phase 3 wire line including cutting and removing tree branches where ever necessary and conveyance of all materials from stacking place.

8

-

-

... More
Supply at site ACSR Racoon conductor

4

-

-

... More
Supply at site ACSR Rabbit conductor

4

-

-

... More
Supply at site ACSR Weasel conductor

4

-

-

... More
Constructing transformer plinth foundation ( cement concrete) inclusive cost of all materials and as per specification of utility.

10

-

-

... More
Dismantling of 3 phase service wire required from OH line.

8000

-

-

... More
Dismantling single phase service wire required from OH line.

12000

-

-

... More
Providing and Laying XLPE insulated/PVC sheathed cable of 1.1 KV grade with aluminium conductor armoured of IS 7098-1/1554-1 of approved make in ground as per IS:1255 including excavation of 30cm *75 cm size trench,25cm thick under layer of sand , second class bricks covering ,refilling earth ,compaction of earth ,making necessary connection, testing etc. as required of size-3.5 C*95 sqmm

6000

-

-

... More
Laying of HT XLPE UG cable (of sizes beyond 3*185 sqmm and up to including 3*300sqmm )as per specification excluding excavation and backfilling

6000

-

-

... More
DISMANTLING

-

-

-

... More
Dismantling( taking out from the ground) if necessary all sizes of XLPE/Pilca/PVC cables, without damaging the cable by excavation in all type of area ( all type of soil) with refilling the excavated trenches as per standards and directions of the engineer in charge . The rate is inclusive of handing over of the dismantled cable of the utility store if not relayed.

5000

-

-

... More
Dismantling( taking out from tarred road and concrete surface) if necessary all sizes of XLPE/Pilca/PVC cables, without damaging the cable by excavation in all type of area ( all type of soil) with refilling the excavated trenches as per standards and directions of the engineer in charge . The rate is inclusive of handing over of the dismantled cable of the utility store if not relayed.

500

-

-

... More
Dismantling( without damage) LT 3 phase 4/5 wire OH line including existing structure, strut, stays, cross arms, insulators etc. and transportation and stacking of all materials as per the instructions including digging out, loading and unloading to lorries without damaging the materials.

21

-

-

... More
Dismantling( without damage) HT 3 phase 3 wire OH line including existing structure, strut, stays, cross arms, insulators etc. and transportation and stacking of all materials as per the instructions including digging out, loading and unloading to lorries without damaging the materials.

16

-

-

... More
Dismantling the existing transformer, transformer structure, transformer foundation etc. of transformer installation and transportation and staking of all materials at suitable location as per instruction of engineer in charge including digging out, loading and unloading on to lorries, etc. of poles of pole transformer and materials without damaging the same.

37

-

-

... More
Dismantling existing one LT PSC/RCC/RS joist/TW pole, fittings, service connections as per instruction including digging out, loading and unloading and stacking at suitable locations including transportation.

35

-

-

... More
Dismantling existing DP structure using A pole/PSC pole as per instruction including digging out, loading and unloading and stacking at suitable locations including transportation.

36

-

-

... More
Dismantling existing one 11 KV A pole / PSC/RCC/RS joist/TW pole, fittings, service connections as per instruction including digging out, loading and unloading and stacking at suitable locations including transportation.

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.