Kochi Metro Rail Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kochi Metro Rail Limited - KMRL Tender

Works
Civil And Construction
Coronavirus COVID 19
Eprocure
Opening Date15 Jan 2020
Closing Date14 Feb 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od144620/2019_2020 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 with cement content 340 kg/m3 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).<br>800 mm dia piles

420

-

-

... More
5.35 : Add for using extra cement in the items of design mix over and above the specified cement content therein

204

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

32012

-

-

... More
20.6.2.1 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test

1

-

-

... More
20.6.2.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test

1

-

-

... More
20.8.2 : Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 ( Part IV) for determining safe allowable lateral load on pile:Above 50 tonne and upto 100 tonne capacity pile.

1

-

-

... More
od131052/2019_2020 : Chipping and removing R.C.C. pile of diameter 600 mm manually / by mechanical means including disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

2

-

-

... More
od131106/2019_2020 : Chipping and removing R.C.C. pile of diameter 700 mm manually / by mechanical means including disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

14

-

-

... More
od131108/2019_2020 : Chipping and removing R.C.C. pile of diameter 800 mm manually / by mechanical means including disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

21

-

-

... More
Sub structure

-

-

-

... More
2.28.1 : Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil

555

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

176

-

-

... More
50.2.3.1 : Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

100

-

-

... More
2.17.1 : Close timbering in case of shafts, wells, cesspits, manholes and the like including strutting, shoring and packing cavities (wherever required) etc. complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5 m

618

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

88

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

88

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

130

-

-

... More
od129752/2019_2020 : Supplying and laying 125 micron seperation sheet over basement fill as directed .

420

-

-

... More
2.35.3.1 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

420

-

-

... More
2.34.1 : Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20%

247

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

57

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

29

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

287

-

-

... More
od144781/2019_2020 : 5.33.1.+5.34.1 Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. <br>All work upto plinth level

78

-

-

... More
5.35 : Add for using extra cement in the items of design mix over and above the specified cement content therein

46.8

-

-

... More
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

43

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

206

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

235

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

11737

-

-

... More
Super structure

-

-

-

... More
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

181

-

-

... More
50.6.2.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

120

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

17

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

169

-

-

... More
od144815/2019_2020 : 5.33.2.+5.34.1 Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. <br>All work above plinth level

448

-

-

... More
5.35 : Add for using extra cement in the items of design mix over and above the specified cement content therein

269

-

-

... More
5.15 : Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in lintels, beams and bressumers including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but excluding the cost of reinforcement with, 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

2

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

1590

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

129

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

864

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

72118

-

-

... More
5.18.1 : Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand ) etc. complete excluding plastering of the jambs, sills and soffits.50 mm thick

72

-

-

... More
Flooring

-

-

-

... More
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick

770

-

-

... More
11.27 : Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

331

-

-

... More
11.21.1.1 : Providing and fixing 10 mm thick acid and /or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile

75

-

-

... More
11.21.2.1 : Providing and fixing 10 mm thick acid and /or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge.In dado/ skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile

75

-

-

... More
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

193

-

-

... More
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

51

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

318

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

64

-

-

... More
8.12 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

129

-

-

... More
8.13.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

24

-

-

... More
8.2.2.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm

46

-

-

... More
od144821/2019_2020 : Providing and laying factory made chamfered edge 80mm thick Cement Concrete paver blocks of of M-30 grade with approved color design and pattern., made by table vibratory method, to attain superior smooth finish using PU or equivalent moulds,laid in required Grey colour & pattern over and including 10cm thick compacted bed of 11.2mm size crushed metal, compacting and proper embedding / laying of inter locking paver blocks into the metal bedding layer through vibratory compaction by<br>using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand<br>in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:

500

-

-

... More
Finishing

-

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

4263

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

1443

-

-

... More
13.9.2 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster

420

-

-

... More
13.18 : Neat cement punning

420

-

-

... More
od132813/2019_2020 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.for outer walls (based on item no;13.21) unit M2

2206

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

4340

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

1786

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

2897

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

800

-

-

... More
13.68.1 : French spirit polishing:Two or more coats on new works including a coat of wood filler

258

-

-

... More
13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

50

-

-

... More
13.71 : Lettering with black Japan pint of approved brand and manufacture

5250

-

-

... More
26.26.1 : Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.

400

-

-

... More
Woodwork and PVC work

-

-

-

... More
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

1

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

128

-

-

... More
9.74.2 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:200x10 mm

64

-

-

... More
50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop

32

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

32

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

115

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

73

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

22

-

-

... More
9.147D.3 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm &sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazingbead / double glazing bead of appropriate dimension . (Area of window above1.75 sqm upto 2.50 sqm).

113

-

-

... More
9.147E.1 : Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).br Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm andsingle glazing bead / double glazing bead of appropriate dimension. (Areaof window above 2.50 sqm upto 4.00 sqm.)

83

-

-

... More
Structural steel work

-

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

460

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

4270

-

-

... More
Roofing

-

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

17082

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

438

-

-

... More
12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).

53

-

-

... More
12.7.2 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.63 mm thick with zinc coating not less than 275 gm/ m2

64

-

-

... More
12.20 : Providing and laying pressed clay tiles ( as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat completeProviding and laying pressed clay tiles ( as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 ( 1 cement : 4 coarse sand mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand) and finished neat complete

107

-

-

... More
Water proofing

-

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

71

-

-

... More
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)

210

-

-

... More
Water supply and sanitary

-

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

6000

-

-

... More
od130788/2019_2020 : Supplying and errecting in position Ferrocement water storage tank made from superior quality ferrocement work with 50 mm min wall thickness and ribbings as required etc complete

9000

-

-

... More
od130789/2019_2020 : Supplying and errecting in position Ferrocement readymade septic tank with superior quality ferrocement having min wall thickness 50 mm in cluding conveyance and errection charges

5000

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

34

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

7

-

-

... More
8.10.1 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.White Agaria Marble Stone

4

-

-

... More
17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

10

-

-

... More
17.5.1 : Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern

4

-

-

... More
17.7.7 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap

7

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

1

-

-

... More
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm

3

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

10

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

5

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

5

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

5

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

5

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

5

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

5

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

5

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

5

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

15

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

50

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

100

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

100

-

-

... More
50.18.8.4.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2

100

-

-

... More
50.18.8.5.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2

100

-

-

... More
50.18.8.7.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2

100

-

-

... More
50.18.9.7.2 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2

100

-

-

... More
50.18.9.8.2 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2

100

-

-

... More
50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2

100

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

50

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

50

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

10

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

10

-

-

... More
18.32.1 : Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

3

-

-

... More
18.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

3

-

-

... More
Laying ov MV Cables

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm

150

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

250

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

20

-

-

... More
MV Cable Jointing &End termination

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 3 1/2 X 240 Sq.mm

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 3 1/2 X 35 Sq.mm

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 4 X 10 Sq.mm

12

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 4 X 16 Sq.mm

12

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominalsize) of size 60cmX60cm at the bottom and 50cmX50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

25

-

-

... More
Cable Trays

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray (galvanization thickness not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray (galvanization thickness not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

35

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray (galvanization thickness not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 600 mm width X 50 mm depth X 2.0 mm thickness

20

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "bends " ( galvanisation not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "bends " ( galvanisation not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "bends " ( galvanisation not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. 600 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
Earthing

-

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

12

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

200

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.(Jointing shall be done by welding and anti corrosive paint shall be applied on joints)

30

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by welding and anti corrosive paint shall be applied on joints)

50

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required

30

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

50

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

50

-

-

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

10

-

-

... More
Providing and fixing 10 SWG dia Copper bare condutor on surface or in recess for earthing as required

100

-

-

... More
Sub Distribution Boards

-

-

-

... More
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 2 + 12 way/14 way, Doubledoor

4

-

-

... More
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 4 way (4 + 12), Double door

4

-

-

... More
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door

8

-

-

... More
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 12 way (4 +36), Double door

2

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

200

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 230 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

4

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 230 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40amps

4

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

4

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

10

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

16

-

-

... More
Supplying and fixing 20 amps, 415 volts, TPN DB with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with selector switch, NO/NC contacts for interfacing with pressure switch and complete with connections, testing and commissioning etc. as required and compactable for connecting the 3HP 3phase motor.(Location Terrace level, fire pump panel)

1

-

-

... More
Miscellaneous items

-

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
Point Wiring

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group

350

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

200

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

100

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

160

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

60

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

80

-

-

... More
TV and Telephone System

-

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmx75mm)

25

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

5

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

3

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4Pair

40

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

40

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm

150

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm

150

-

-

... More
Supply & installation of Krone type telephone tag block of following sizes in sheet metal enclosure of suitable dimensions fabricated out of 16 SWG sheet steel with castle key lock, hinged type cover including termination of telephone cables, making connections, painting of box etc. complete as required.50Pair

4

-

-

... More
Supply and drawing of following sizes of 0.60mm diameter annealed tinned copper conductor PVC insulated and PVC sheathed armoured telephone cable in ground or on existing cable tray-50Pair

100

-

-

... More
Supply, erection and commissioning of 2 way/3 way /4 way splitter for cable TV in MS enclosure as required at site and as approved by consultant.

4

-

-

... More
Lighting Fixture and Fans(erexction only)

-

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

4

-

-

... More
Installation, testing and commissioning of pre-wired LED light fittings, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

245

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

60

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.up to 450mm sweep

6

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

6

-

-

... More
Lightning Conductor

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required

6

-

-

... More
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.

6

-

-

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

6

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

120

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)

150

-

-

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

6

-

-

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

150

-

-

... More
Fire Alarm and Early Detection System

-

-

-

... More
Steel Conduit:Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25mm

20

-

-

... More
Wiring:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2x1.5 sqmm

200

-

-

... More
Manual Call Point:Supply, installation, testing and commissioning of manual fire alarm stations (pill boxes) complete with auxiliary contact hammer, push button enclosed in MS box, front cover sealed in front by means of breakable glass, neoprene gasket etc. complete

6

-

-

... More
Speakers / Hooters :Supply, installation, testing and commissioning of Electronics speakers / hooters housed in recessed box electric type, 90 DB sound level, die cast aluminium housing, 16 SWG CRCA sheet metallic box (with line matching transformer) complete as required.

6

-

-

... More
Sounder:Supply, Installation, Testing and commissioning of Fire Alarm Hooter cum Speaker having an Audible range of 1 KM.

2

-

-

... More
Repeater Panel:Supply, installation, testing and commissioning of 16 Zone Repeater Fire Control Panels at Stilt level

1

-

-

... More
Fire Alarm Control Panel:Supply, Installation, Testing and commissioning of Wall Mounting 6 zone Main Fire Alarm Panel (in guard room) with Window type Annunciation to indicate fire and fault,LED lamps for visual indication,audio alarm unit push buttons for acknowledge, test, reset complete with power supply unit for 24volt DC from 230volt AC with back up by a battery complete as per details.

1

-

-

... More
Supply of MV cables

-

-

-

... More
Supply of the following sizes multicore stranded/solid aluminum conductor, PVC insulated armoured, extruded outer PVC sheathed 1100 Volts grade cables complete in all respects as specified.3.5Cx240sqmm

150

-

-

... More
Supply of the following sizes multicore stranded/solid aluminum conductor, PVC insulated armoured, extruded outer PVC sheathed 1100 Volts grade cables complete in all respects as specified.3.5Cx35sqmm

100

-

-

... More
Supply of the following sizes multicore stranded/solid aluminum conductor, PVC insulated armoured, extruded outer PVC sheathed 1100 Volts grade cables complete in all respects as specified.4CX16sqmm

100

-

-

... More
Supply of the following sizes multicore stranded/solid aluminum conductor, PVC insulated armoured, extruded outer PVC sheathed 1100 Volts grade cables complete in all respects as specified.4Cx10sqmm

50

-

-

... More
LT Distribution Boards

-

-

-

... More
Design, Manufacture, Supply, unloading and placing it on foundation, Installation, Testing and Commissioning of L.T. panels, main distribution boards, feeder pillars, main emergency panels, emergency & normal panels, sub distribution boards etc. fabricated out of 14 SWG CRCA sheet steel in cubicle formation with reinforcement of suitable si7z iron angle; channel, T-irons & kits wherever necessary cable gland plates shall be provided at top and bottom both the board shall be treated with all anticorrosive before painting as per standards with two coats of red oxide primer and final approved shade of enamelled paint. Two nos.-earthing terminals shah be provided for 3 phase distribution boards lifting hooks shall be provided in case of large boards, the boards shall be fabricated in easily transportable sections and length, height, depth etc. to match with site conditions. An approval shall be taken for Each panel before final manufacture from Architect/ Consultant / Society or their authorised representative. Gcomponent after Factory Testing is conducted. MAIN EMERGENCY PANEL(i) Incomings:1 Nos. 200 Amps. 4P feeder each having one number 3 phase, 415 Volts, 50 Hz, 50 KA, 4P, 315 Amps.MCCB with microprocessor under voltage, overload/short circuit and earth fault releases, on/off/trip indication light (LED type) and require auxiliary contacts etc. complete in all respects.(FOR DG ONLY)1 Nos. 200 Amps. 4P feeder each having one number 3 phase, 415 Volts, 50 Hz, 50 KA, 4P, 315 Amps.MCCB with microprocessor under voltage, overload/short circuit and earth fault releases, on/off/trip indication light (LED type) and require auxiliary contacts etc. complete in all respects.(FOR KSEB ONLY). 1 no of 3 phase KSEB tested energy meter class 0.5s and 4 nos of CT of class 0.5s. Bus bar:1 set of 400 Amps, 415 volts, 3 phase, 4 wire colour coded aluminium bus bar. Outgoings:12 Nos. 63 Amps TPN feeder each having one number 3 phase 415 Volts, 50 Hz,25 KA, front operated 63 Amps. MCCB.4 Nos. 40 Amps TPN feeder each having one number 3 phase 415 Volts, 50 Hz, 25KA, front operated 63 Amps. MCCB.4 Nos. 20 Amps fp feeder each having one number 3 phase 415 Volts, 50 Hz, 10KA, front operated 20 Amps. FP MCCB.COMPONENTS FOR AMF OPERATION OF DG SET - 01 SET ( 1 SET FOR EACH DG SET)Each AMF section shall have the one set of following items:Relays, control contactors, Aux.Relays, Timers:1 No. Microprocessor based AMF logic relay having UV and OV, Phase reversal, engine start relay ,engine cranking relay, Auto/Mannual/ test / service etc.1 Set of All other auxiliary relays, auxiliary / control contactors ( 24V DC and 230V AC), timers, Three impulse unit , Master trip relay, etc of suitable rating and quantity as required to achieve AMF function as described in technical specifications.1 Set LED Indication lamps, Push buttons, window annunciation fascia etc of required quantity as per technical specifications.Metering:1 set of Digital AC Ammeter of suitable range with built-in selector switch, Cast Resin CTs & control MCBs.1 set of Digital AC Voltmeter of suitable range with built-in selector switch & control MCBs.1 no.Digital Frequency meter,1 No.Digital Power factor meter,,1 No. Digital DC Voltmeter,,1 No. Digital DC Ammeter..Others:1 set of required quantity of suitable range and accuracy class of Cast Resin CTs for Metering & Protection,1 set of required quantity and rating of HRC fuse for control & protection circuits - 01 Set,1 set of 24V DC battery charger comprising of transformer, rectifier unit & charge rate selector switch etc., - 01 Set.1 No. Hooter,1 Lot of Control wiring from DG set to AMF Panel.All other accessories & components required for proper operation of AMF logic and inter locking etc.Instruments:1 Nos. 0-500 Volts, 96 sq.mm voltmeter with protection fuses and selector switch.1 Nos. 0-200 Amps, 96 sq.mm ammeter with 200/5A CT's and selector switch.KWH meter (digital type) to read SEB supply & DG supply for common services -1 set.1 Set R Y B phase indicating lamps with protection fuses.1 Lot of control wiring.1 Set of designation plates.Other items such as:-illumination light interlocked with doors.Notes:All MCCB shall have operating rotating handle.Main emergency panel cum AMF panel as described above.

1

-

-

... More
Lift Panel

-

-

-

... More
S/F of lift panel with Incoming:1 Nos. 63 Amps. TPN feeder each having one number 3 phase, 415 Volts, 50 Hz, TP, 63 Amps.10 KA MCB complete in all respects.Bus Bar:1 set of 200 Amps, 415 volts, 3 phase, 4 wire colour coded Cu. bus bar.Outgoing:1 No. 40 Amps FP feeder each having one number 3 phase 415 Volts, 50 Hz, 100mA front operated 40 Amps. 4P EL+MCB.3 Nos. 6-32 Amps. 10 KA SP MCB.

1

-

-

... More
Miscellaneous items

-

-

-

... More
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M)

2

-

-

... More
Supply and fixing of First aid box as approved by Indian red cross conforming to IS : 2217.

1

-

-

... More
Supply of rubber gloves of 11 KV grade as per IS : 4770.

1

-

-

... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of 2.5 mm thick +/- 10% as per IS: 15652, suitable for all voltages not exceeding 11 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at site as per site requirments.

3

-

-

... More
5 HP/ 3.7 KW open well submersible pump. Pipe size 50X40 mm, head 30.0 / 40 meter, Discharge 6.1 / 4.3 Lps Aquatex make model AMH -31 NS or any other approved make.

1

-

-

... More
Supplying fully automatic star delta until push button type with suitable wires, 3 phase Motor starter for the above motor pump with ammeter , voltmeter, overload, single phase preventing protection

1

-

-

... More
The PVC insulated and sheathed 3 core 4 sq.mm copper cables are used for giving electrical connection to the submersible pump motors. - These are manufactured keeping in mind the severe, tough and difficult conditions in which they have to operate. - These cables conform to and are marked IS 694: 1990 up to 4.0 sq. mm. - Manufactured from bright-annealed 99.97% pure bare copper conductors these cables have low conductor resistance. - The inner cores are insulated with a special grade PVC compound formulated and manufactured in-house. - The tough robust outer PVC jacket protects it from the oils, greases, various chemicals and abrasions, thereby giving long life and electrical safety

30

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.150mm dia

30

-

-

... More
Supply, installation, testing and commissioning of MNRE approved & conforming to IS: 12033 P-1,2,3 & 5 evacuated tube collector type solar hot water system with collector, insulated stainless storage tank with electrical back up, MS stand for collector & tank etc. as required of 250 litres apacity.

1

-

-

... More
Providing and fixing heavy duty, double ball bearing and with sturdy mesh guard: aluminium alloy one piece of blade wall mounting oscillating type air circulator conforming to IS: 2997, including fixing with anchor bolts, regulator making connection testing etc. as required..400 mm sweep with three speed regulator

2

-

-

... More
Supply & fixing of CPVC Rigid 25 mm drain piping of 6 Kg/cm2 with EP section insulation

35

-

-

... More
Lightning Fixture and Fans(supply only)

-

-

-

... More
1 x 18 W LED baton Tube fitting as per Bajaj BJCEB or equivalent approved make

200

-

-

... More
Wall Fixture "D-Type" as per Decon 05 SM with 18 W LED or equivalent approved make

4

-

-

... More
Ceiling Mounted Round Surface LED Fixture as per Bajaj "BCSC 218 LEDL W2EB" orequivalent approved make

40

-

-

... More
Bulkhead fixture as per Philips NXC 101 with 9 W LED or equivalent approved make

15

-

-

... More
Supply, installation, testing and commissioning of 240 volt single phase ceiling fans without electronic regulators including all standard accessories complete as required and as below.1200 mm sweep ceiling fans

60

-

-

... More
Supply, installation, testing and commissioning of 380 mm dia 240 Volt single phase 900 rpm heavy duty exhaust fans with louvered shutters complete as required and as below.380 mm dia

4

-

-

... More
External Lumination

-

-

-

... More
Gate Light:Supply, Installation, wiring, connection, testing and commissioning of gate light conforming to the technical specifications and drawings forming part of this document. The work for each light point comprises of:Installation of 50 mm dia, 600 mm longGI tubular pipe .Digging in wall for grouting the bracket.Grouting the pipe in the wall. (The civil construction materials are the part of the supply against this assignment)Mounting the gate light LED luminarie equivalent to Philips make HPS360 1xCDMTT-150W GR with one no.CDMT lamp on the bracket top.Connecting the fixture by using 3 Nos. 2.5mm PVC flexible copper wires of colour green, red and black to the junction box.Testing the connections and completing the installation.Painting the bracket with two coats of red oxide and two coats of aluminum paint

2

-

-

... More
Road Light:Supply, Installation, wiring, connection, testing and commissioning of peripherial ROAD lighting system conforming to the technical specifications and drawings forming part of this document. The work for Each light point comprises of:Supply of single piece 6000 mm long 3 mm thk GI octagonal pole with 300mm x 300mm x 16 mm thk base plate 155 mm dia bottom and to mm dia of top section with 48mm dia 1000mm long arm having door opening of 1500mm at shoulder above height with foundation bolt and all other require accessories complete in all manners.Design and supply of all materials and casting of suitable shallow foundation with square footing using Concrete for the pole considering the safe soil bearing capacity as per site condition or minimum at site as 10 T/sq. mtr. at suitable depth, and supply a set of tor steel foundation bolts manufactured from special steel along with nuts, washers anchor plates and templates for Each pole. The erection of the pole shall be done with the help of suitable equipments. The foundation design and structure design of mast shall be vetted from Engg. College/ SERC before installation.Supply, Installation, testing and commissioning of suitable rating MCB and connector to connect for terminating incoming and outgoing 4-core cable.Supply,Handling, Storing, Installation, testing and commissioning of street light fixture Philips Cat. No. BRP322 48LED CW 95 FG S1 PSU GR or approved equivalent (Minimum IP-65 ) on the bracket top.Connecting the fixture by using 3c x 2.5 sq.mm PVC flexible copper wires of colour green, red and black to the junction.Testing the connectiuons and completing the installation.

4

-

-

-

-

-

... More
Supplying, installation, testing and commissioning of 10 Passenger (680 Kg) lifts having contract speed of 1. 0 MPS serving different floors in the lift shaft as per detailed specifications and as under:Floor: G+3.Travel : 18 meter (approx.)Stops and Opening : 4 Stops & 4 Openings.Position Of Machinery : MACHINE ROOMLESS - GEARLESS.Automatic rescue device complete with dry maintenance free batteries as required.Type of Control System : MICROPROCESSOR BASED SIMPLEX SELECTIVE COLLECTIVE CONTROL WITH / WITHOUT ATTENDENT.power:AC 400/440 VOLTS, 3 PHASE, 50 CYCLES.Type or Design of Lift Car : STAINLESS STEEL - HONEYCOMB -Type Of Car Front Entrance Protection : POWER OPERATED CENTRE OPENING SLIDING DOOR - STAINLESS STEEL - HONEYCOMB.Land Entrance Protection : CENTRE OPENING SLIDING DOOR - STAINLESS STEEL - HONEYCOMB.Landing Door Frame : STAINLESS STEEL - HONEYCOMB.Lift as per Above description complete as required.Contractor shall maintain lift for 5 years after DLP in comprehensive manner.

1

-

-

... More
UPS System

-

-

-

... More
Supply, Installation, Testing and Commissioning of true parallel redundant 2 x 15 kVA, online, UPS system suitable for providing power supply to emergency lighting and Computerised Control panel load of approved make, suitable for incoming 415 volts, 3 phase +10 % - 20%, 50 Hz, supply and single phase output voltage, variation ± 1%, including transformer, rectifier/dual converter, static switch, inverter, filter, Bypass & static transfer switch for automatic switch over without giving any break of power, maintenance bypass switch, Micro processor/ software controlled annunciation,protection(including against input phase reverssal), and menu run diagnostic module,associated cabling and connections/ terminations, erection including associated foundation/ masonorey or RCC work for mounting on base channels etc. complete as per specifications and as required.

1

-

-

... More
Supplying and fixing modular type 32A DP Switch with indicator on the modular plate & in the existing box as required.

6

-

-

... More
Fire Signages: LED signage with four to six hour battery back up for Fire Duct, Exit, Fire Exit, Fire Lift, Fire Control Room, Fire Pump Room, PA Panel, Fire Alarm Panel)

12

-

-

... More
Digital timer on Distribution boards

6

-

-

... More
Emergency Lighting Panel

-

-

-

... More
Emergency lighting panel (EMLP) - Type-1 .INCOMER 1 no. 125 A, 240V, Ics= 25 kA, DP MCCB with bimetallic over current and magnetic short circuit releases having:1- set Red/Green ON/OFF indicating lamps.1- set of phase indicating lamps .BUSBAR-Electrolytic high conductivity tinned copper phase and neutral busbars rated at 125A having a maximum current density of 1.4 A per sq mm suitable to with stand symmetrical fault level of 25kA. The neutral busbar is to be of same capacity.OUTGOING -4 nos. 25 A, 10kA, 240V, DP MCB ELCB/RCCB 30mA sensitivity,Indication lamps for each outgoing feeder,6 nos. 40 A, 25kA, 240V, DP MCB ELCB/RCCB 30mA sensitivity,Indication lamps for each outgoing feeder

1

-

-

... More
Diesel Generator

-

-

-

... More
Design, Manufacture & Supply & installation of DG sets along with all accessories with (AMF Panel) as given in Detailed BOQ for the following capacity DG sets including Exhaust piping with GI gladding as per the building height + 3mt, External fuel tank of 990 litres and its fuel piping, one semi rotary hand pump, all required control cables etc. Contractor shall maintain DG Set during DLP period in comprehensive manner.100KVA

1

-

-

... More
Fire figthing

-

-

-

... More
Supply, installation, testing & commissioning of electric driven automatic fire booster Pump suitable for automatic operation consisting of the following:Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump.Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. Location at Terrace Level.Common bed plate of fabricated mild steel channel or cast iron type.Suitable reinforced cement concrete pump foundation (Civil vendor's scope) including cushy foot mounting, foundation bolts, washers as required. Painting of pump with IS red 5 shade 276.The pump shall be of the following specifications:Discharge - 450 lpm,Head - 30 m,No. of stage preferred - Single ,Speed RPM - 2900Material of construction .a) Impeller - Bronze,b) Casing - C.I.,c) Shaft & Shaft Sleeve - SS-410,d) Bearing - Grease Lubicated,e) Seal & Make - Mechanical,Type of pump - End suction

1

-

-

... More
Providing and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20 mm dia 37.5 m long high pressure hose to I.S. 5132 with 5 mm outlet SS nozzle with shut off valve (I.S. 884-1969). Name of Manufacturer should be embossed on the drum.

4

-

-

... More
Providing and fixing door with frame for all internal fire hydrants fabricated from 16 gauge CRCA M.S. sheet double door including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 5 mm thick float glass approved by local Fire Authority, stove enameled fire red finish with " fire hose' written on front with radium strip suitable to house 15 mm long four length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.).

4

-

-

... More
Providing and fixing ABC type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Capacity 6.0kg. I.S.I. Marked.

12

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.Capacity 4.5 kg. I.S.I. Marked.

12

-

-

... More
Providing and fixing Two Way Fire Brigade Inlet to Hydrant outside the Building with Butterfly valve and non return valve complete in all respects. (Butterfly valve & Non return valve shall paid seperately).100 mm dia

1

-

-

... More
Providing and fixing in position the industrial type Pressure Gauges with gun metal / brass valves complete as required

2

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified-100 mm dia

4

-

-

... More
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.100 mm dia

2

-

-

... More
Providing and installation pf 20mm ball valve with all accessories

4

-

-

... More
Providing and laying M.S (Heavy Class) pipe IS:1239 marked including all accessories such as screwed/welded flanges, tees, reducers etc. conforming to IS standards complete including welding, jointing and painting. The rates shall be inclusive of neoprene gaskets, nuts, bolts etc. as required.M.S pipe tied in ceiling, walls, columns for all heights with hangers/supports and fasteners all as per drawings & specifications including cutting of holes in walls/beam/ceiling etc. and making good the same as required. The rates shall be inclusive of painting for M.S. pipes with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation.(Sample of hangers / supports to be approved by the Engineer-in-Charge.) 100 mm dia pipe

40

-

-

-

-

-

... More
Providing, fixing, testing and commissioning of Hi wall split unit air conditioing air cooled type with evaporator coil, fan and fan motor ,air cooled condenser with hermetically sealed rotary compressor, condenser coil, refrigerant pipe, corded remote controller and complete with electrical Wiring as required.Price of the unit shall be inclusive of the Voltage Stabilizer.Note:Providing and fixing of M.S. angle iron frame work for outdoor unit including P.O. painting of the same is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer-in-change before proceeding further.Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 9 mm thickness and cabling for all types of split AC units. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.1.5TR

4

-

-

... More
Providing, fixing, testing and commissioning of Hi wall split unit air conditioning air cooled type with evaporator coil, fan and fan motor ,air cooled condenser with hermetically sealed rotary compressor, condenser coil, refrigerant pipe, corded remote controller and complete with electrical Wiring as required. Price of the unit shall be inclusive of the Voltage Stabilizer.Note:Providing and fixing of M.S. angle iron frame work for outdoor unit including P.O. painting of the same is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer-in-chage before proceeding further.Providing, fixing and testing of copper refrigerant piping of apppriate sizes duly insulated with nitrile rubber insulation of 9 mm thickness and cabling for all types of split AC units. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.2TR

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.