KITCO Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Mar 2025
Closing Date31 Mar 2025
Tender Amount₹ 1,12,00,000 
Notes
Download

Costs

Summary

Construction Of Critical Care Block At Gh Pathanamthitta Electrical Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

140.8

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

38.28

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

25595.2

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

12375

-

-

... More
90.14.10.2 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

22

-

-

... More
90.14.10.4 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

2

-

-

... More
od386907/2022_2023 : Supplying and fixing of 2 A SP MCB (C curve), 10 kA breaking capacity in the existing panel for control devices as required in complete.

30

-

-

... More
od386911/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - BLUE Colour in the existing panel.

6

-

-

... More
od386912/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, up to 160A

27

-

-

... More
od386914/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, 320A-400A

1

-

-

... More
od386915/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour in the existing panel.

12

-

-

... More
od386923/2022_2023 : Supplying and fixing of Resin Cast metering CT 63/5A 10VA accuracy class 1, in existing panel and giving connection complete.

3

-

-

... More
od386925/2022_2023 : Supplying and fixing of Resin Cast metering CT 125/5A 5VA accuracy class 1, in existing panel and giving connection complete.

11

-

-

... More
od386934/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 4 POLE MCCB ISOLATOR

1

-

-

... More
od387486/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 40A, 3 POLE MCCB ISOLATOR

2

-

-

... More
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

27

-

-

... More
90.14.11.15 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A

1

-

-

... More
od387846/2022_2023 : Supply , conveyance and Fixing three phase voltmeter accuracy class1 in the existing Panel as required.

2

-

-

... More
od387849/2022_2023 : Supply , conveyance and Fixing three phase ammeter accuracy class1 in the existing Panel as required.

4

-

-

... More
od387941/2022_2023 : Supply installation, testing and commissioning of three phase DOL starter suitable for 0.25 to 7.5 HP , 440v, 50 Hz in existing panel as required .

7

-

-

... More
od387943/2022_2023 : Supply , conveyance and Fixing voltmeter selector switch in the existing Panel as required.

2

-

-

... More
od387944/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 100A, 3 POLE MCCB ISOLATOR

2

-

-

... More
od387945/2022_2023 : Supply , conveyance and Fixing Ammeter selector switch in the existing Panel as required.

1

-

-

... More
od388051/2022_2023 : Supply and installation of ON OFFindication lamp in existing panel as required

22

-

-

... More
od398220/2022_2023 : Supply and Fixing of Digital Multifunction meter to read: W, Wh, PF or VA, Vah, PF or V AR, V ,A Rh, PF - 3 phase accuracy class 1 LED in the existing Panel as required.

9

-

-

... More
od14307/2023_2024 : Supplying and fixing of Resin Cast metering CT 400/5A 10VA accuracy class 1, existing panel and giving connection complete

1

-

-

... More
od14308/2023_2024 : Supply and installation of push button in existing panel as required

10

-

-

... More
od14309/2023_2024 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 25/36 kA (Ics=100%Icu), 3 pole and neutral link current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

2

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

1

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

9

-

-

... More
od15665/2023_2024 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 3 POLE MCCB ISOLATOR

1

-

-

... More
od42420/2023_2024 : Supply installation, testing and commissioning of FASD starter for 40 hp , 440v, 50 Hz in existing panel as required

1

-

-

... More
od42421/2023_2024 : Supply installation, testing and commissioning of FASD starter suitable for 5 hp ,440v, 50 Hz in existing panel as required

1

-

-

... More
od42526/2023_2024 : Supplying and fixing of Resin Cast metering CT 100/5A 15VA accuracy class 1, in existing panel and giving connection complete.

3

-

-

... More
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required125 Amp, 36 KA

2

-

-

... More
od42609/2023_2024 : Supply, Installation, Testing & Commissioning of 100A FP MCCB isolator in IP65 weather proof enclosure on surface including all the mounting accessories, internal wiring etc as required complete

2

-

-

... More
od42624/2023_2024 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 400A, 25/36 kA (Ics=100%Icu), 4 pole and neutral link current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

1

-

-

... More
od68922/2023_2024 : Supply, Installation, Testing & Commissioning of 25/32A FP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

2

-

-

... More
od76563/2023_2024 : Supplying and fixing of SPD Class B+C/Type 1+2, Multi stage protection device should be suitable for TNS configuration and should be DIN Rail mounting type. Surge Protection Device Tested as per IEC 61643 Part 11:2016 . Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV . The Surge Protection Devices should have TOV safe fail for 120 Min : 442 V and without Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25 kA/50 kA . Complete with back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <25 nano sec. The product should be tested and approved by any one of the following external testing institutes (UL, KEMA, OVE, VDE)

1

-

-

... More
CABLES AND CABLING

-

-

-

... More
od306814/2022_2023 : Supply of 4C 16 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

590

-

-

... More
od306815/2022_2023 : Supply of 4C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

365

-

-

... More
od306817/2022_2023 : Supply of 3.5C 120 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

88

-

-

... More
od306831/2022_2023 : Supply of 3C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

88

-

-

... More
od306832/2022_2023 : Supply of 2C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

325

-

-

... More
od306833/2022_2023 : Supply of 4C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

567

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

675

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

45

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1276

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

80

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

130

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

25

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

18

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

270

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness

210

-

-

... More
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
4.7.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

8

-

-

... More
4.8.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.8.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.8.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.9.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.9.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.9.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.10.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.10.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
od309083/2022_2023 : Supply of 3C 6 sqmm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

22

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

10

-

-

... More
od309390/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 6 sq.mm

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

30

-

-

... More
9.1.10 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 35 sq. mm (28mm)

2

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

50

-

-

... More
od392063/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 70 sqmm Al

165

-

-

... More
od399651/2022_2023 : Supply of 3C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

22

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

220

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

220

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

100

-

-

... More
od402752/2022_2023 : Supply of 3.5C 185 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Al conductor cable conforming to IS 7098 (Part 1) amended upto date.

550

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

11

-

-

... More
od42718/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.3C 4 Sq.mm Cu

16

-

-

... More
od49552/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.2C 4 Sq.mm Cu Code

16

-

-

... More
od49852/2023_2024 : Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C 4 Cu

34

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

10

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

20

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

356

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

20

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

2532

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1708

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

2000

-

-

... More
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

180

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

300

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

750

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

450

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

110

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

55

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

110

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

55

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

3

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

74

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

10

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

55

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

75

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

3

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

184

-

-

... More
od305266/2022_2023 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

23

-

-

... More
od305268/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

33

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

55

-

-

... More
MCBs AND DISTRIBUTION BOARDS

-

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

17

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

6

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

7

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

216

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

22

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

40

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
od309048/2022_2023 : Supply, Installation, Testing & Commissioning of 25/32A DP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

2

-

-

... More
od309049/2022_2023 : Supply, Installation, Testing & Commissioning of 25/32A FP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

6

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od365386/2022_2023 : Supply and fixing of following 40-63A FP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required

9

-

-

... More
od367250/2022_2023 : Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "D" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

176

-

-

... More
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

17

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

2

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

6

-

-

... More
od395788/2022_2023 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6-32A TP MCB, D-CURVE

4

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

7

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

11

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

11

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
od50490/2023_2024 : Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete

1

-

-

... More
od50506/2023_2024 : Supply, Installation, Testing & Commissioning of 400A, TP+NL, 36 KA, MCCB with rotary handle in the existing substation main panel in the outgoing side replacing existing 250A breaker including all necessary fabrications, bus bar, instruments, control devices and required control wiring etc. which is similar to other outgoings in complete installation capable for charging the feeder.

1

-

-

... More
od50563/2023_2024 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.4 pole

11

-

-

... More
od52320/2023_2024 : "Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing panel complete with connections, testing and commissioning etc. as required. Triple pole and Neutral"

11

-

-

... More
od58984/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6-32A DP MCB, D-CURVE

7

-

-

... More
od59302/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40-63A FP MCB, D-CURVE

6

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od305288/2022_2023 : Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal framework working on 230 V AC supply complete with all accessories as required.

28

-

-

... More
od305290/2022_2023 : Supply of 450mm sweep heavy duty exhaust fan in metal body with grill/ louvers working on 230 V AC supply complete with all accessories as required

4

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

420

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

567

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

32

-

-

... More
1.42 : Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

30

-

-

... More
od309335/2022_2023 : Supplying and fixing extra conduit down rod of G.I. pipe 15 mm dia, heavy gauge including painting etc. for ceiling fans as required

79

-

-

... More
od309336/2022_2023 : Supplying and fixing Metal conduit Pipe of more than 8 mm dia, including powder coating/Spray painting similar to the colour shade of the light fixture and all accessories in complete for suspending the light fixture as required.

620

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

80

-

-

... More
od386692/2022_2023 : Supply of 10 (+/-2) W High efficient LED batten surface/wall mounted, System efficacy of more than 100 lm/W and lumen output of luminaire greater than 1000 lumen, designed extruded channel in thermally conductive material with plastic with HET diffuser. CRI >80, Power factor>0.9, CCT - 6500K, 50000 burning hours as per L 70 criteria.

47

-

-

... More
od386693/2022_2023 : Supply of 40W (+/-2) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing & High Efficiency Translucence (HET) diffuser. CRI>80, IP65 from front, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Powerfactor>0.9, Surge protection-2 kV, prewired electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation

8

-

-

... More
od16036/2023_2024 : Supply of 18W (+/-2), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life THD0.9, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

7

-

-

... More
od16037/2023_2024 : Supply of 18W, High efficient surface mounted LED round downlighter with white powder coated,Aluminium die cast aluminium housing.CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD0.9, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

20

-

-

... More
od16038/2023_2024 : Supply of 36W , High efficient recess mounted 2 x 2 LED luminaire with CRCA housing &CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @L70 life.THD0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy> 110 lm/W including all accessories necessary as required to complete installation.

51

-

-

... More
od16039/2023_2024 : Supply of Integral 2x2 LED, IP 20, 36W LED Surface mounted fixture with System efficacy of more than 100lm/W and system lumen output 3000lm. Luminaire shall have translucence HET diffuser for Uniform illumination and wider light distribution. LED. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. .

13

-

-

... More
od53037/2023_2024 : Supply of 40W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire

71

-

-

... More
od54000/2023_2024 : Supply of Integral, SMD 1x4 LED, IP 20, 36W +/- 4W LED Suspended light fixture with System efficacy not less than 110 lm/W and system lumen output more than 3600lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA housing. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Required nos. of Clamps and other accessories suitable for mounting Conduit pipe/rod to suspend the fixture from the ceiling.

110

-

-

... More
od58351/2023_2024 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

80

-

-

... More
od58352/2023_2024 : Supply of 20W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire

107

-

-

... More
od75708/2023_2024 : Supply of IP 65 & IK 08 LED surface mounted Bulkhead fixture with System efficacy of more than 105 lm/W. Luminaire shall be made up of Die Cast Aluminium for efficient heat dissipation. Luminaire shall have Polycarbonate diffuser for Uniform illumination and wider light distribution. The LEDs used should be with CCT of 5700 K and CRI > 70, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% including all accessories necessary as required to complete installation.

11

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

10

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

130

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

180

-

-

... More
od305460/2022_2023 : Supply and fixing of First aid box

1

-

-

... More
od305461/2022_2023 : Supply and fixing anodised aluminum glass framed shock treatment chart.

2

-

-

... More
od305462/2022_2023 : Supplying of Rubber hand gloves suitable for 11 KV.

1

-

-

... More
od309152/2022_2023 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size including lamination etc. as required complete on wall.

1

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

3140

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

270

-

-

... More
od399693/2022_2023 : Earthing with CI earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
od55236/2023_2024 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of size 2m x 1m for 3.3kV grade 2mm thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound

15

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

100

-

-

... More
od160083/2023_2024 : Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

100

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

230

-

-

... More
od308770/2022_2023 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip

10

-

-

... More
od308777/2022_2023 : Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing masonry enclosure with heavy duty CI cover plate of 300X300 mm having locking arrangement.

10

-

-

... More
od50571/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for Sheet roof with the required mounting clamps , cross connectors , expansionpiece and other accessories required as per IEC 62305-3

165

-

-

... More
od50572/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

420

-

-

... More
UPS AND ACCESSORIES

-

-

-

... More
od11063/2023_2024 : Supply, Installation, Testing and Commissioning of 40kVA (N+1 arrangement), three phase input, three phase output, true on-line modular UPS system with 15 minutes back up at unity pf, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc. as required complete having following specification. The UPS system consist of 2 no's of 20 KVA modular units and must have an N+1 rack for mounting UPS modules. Aso required a set of battery bank mounted in battery racks.. Fully digital controlled based on DSP. Power factor corrected from end 0.95 Pure sine wave output. Full time output voltage & frequency regulation. Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch, Auto temperature compensation etc. as required

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.