KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Eprocure
Opening Date18 Feb 2020
Closing Date5 Mar 2020
Tender Amount₹ 5,69,74,345 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited

640

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

80

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

150

-

-

... More
2.9.3 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)

150

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

883

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

118

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

148

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

1500

-

-

... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

1500

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

5

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

4

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

6

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

153

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

40

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

92

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

127846

-

-

... More
4.13 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

92

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

409

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1030

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

2248

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2194

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1220

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

70

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

760

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

265

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

2110

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

1

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

41772

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

102510

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

960

-

-

... More
od117637/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. & All work upto plinth level

352

-

-

... More
od117638/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. & All work above plinth level upto floor V level

705

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

697

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

15

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

235

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

21

-

-

... More
8.12 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

45

-

-

... More
8.13.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

100

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

12

-

-

... More
9.14 : Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)

70

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

4

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

200

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

24

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

24

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

50

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

46

-

-

... More
9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.

25

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

135

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

40

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

2

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded.

60

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately.

4

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

15

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

10

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

55

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

4580

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

35

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

9

-

-

... More
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

450

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1680

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

180

-

-

... More
13.4.2 : 12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand)

8110

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2530

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

18970

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

260

-

-

... More
13.41.1 : Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work ( Two or more coats) over and including priming coat with water thinnable cement primer

80

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

7485

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

60

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

2553.263

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

5

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

7425

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

5

-

-

... More
14.70 : Melamine polishing on wood work ( one or more coat)

160

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

1428

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

10

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

195

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

195

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern.

760

-

-

... More
19.18.3 : Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg

7

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

1130

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

1130

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

256

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

60

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

135

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

790

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

785

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

240

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

720

-

-

... More
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

6

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

52

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

240

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

260

-

-

... More
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete

3

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

27

-

-

... More
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

2

-

-

... More
50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood

70

-

-

... More
50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood

70

-

-

... More
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop

19

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

16

-

-

... More
od117632/2019_2020 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.

3

-

-

... More
od117633/2019_2020 : Extra for providing richer mixes at all floor levels. & Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

75

-

-

... More
od117634/2019_2020 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

1755

-

-

... More
od117636/2019_2020 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

3

-

-

... More
od117639/2019_2020 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level up to floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

50

-

-

... More
od117640/2019_2020 : Providing and fixing zinc alloyed (white powder coated) touch lock for Aluminium/uPVC sliding window with necessary screws etc. complete.

326

-

-

... More
od117641/2019_2020 : Providing and fixing S.S fan clamp of 16mm dia in RCC slabs, beams including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge at all levels.

50

-

-

... More
od117643/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. & In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

87

-

-

... More
od117644/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. & & In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

163.56

-

-

... More
od117646/2019_2020 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

150

-

-

... More
od117647/2019_2020 : Providing and fixing PVC tile edging to match the wall tiles and finishing as directed by the Engineer-in-Charge at all levels.

120

-

-

... More
od117648/2019_2020 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )

510

-

-

... More
od117649/2019_2020 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight & of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

4

-

-

... More
od120644/2019_2020 : Providing weep holes in brick / plain / reinforced concrete abutment, wing wall / return wall with 100mm dia PVC pipe 10kg/cm2, extending through the full width of the structure with slope of IV : 20H towards drawing face. complete as per drawing and technical specification

180

-

-

... More
od121015/2019_2020 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S top cover of required thickness for rolling shutters including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top cover

10

-

-

... More
od122733/2019_2020 : Providing and fixing 110mm dia perforated pipes in filter media complete as directed by the Engineer-in-Charge. The rate including cost and conveyance of all materials, labour and fixing charges, etc.

60

-

-

... More
od122734/2019_2020 : Supplying and laying good quality filter media (coarse aggregates of varying sizes from 53mm to 90 micron) brought from outside including cost of all materials, labour charges, transportation, loading, unloading ,taxes etc complete as directed by the Engineer- in -charge. The work has to be executed as per detailed specifications, and or as approved by Engineer - in - Charge.

125

-

-

... More
od181495/2019_2020 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. & Fixed to openings/ wooden frames with rawl plugs screws etc

4876

-

-

... More
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia

30

-

-

... More
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

19

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

22

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

6

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

6

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

6

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

12

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

48

-

-

... More
18.9.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes

12

-

-

... More
18.9.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes

12

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

12

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

120

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

12

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

10

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

10

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

10

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

5

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

5

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

5

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

1

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

6

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

6

-

-

... More
18.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

10

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

6

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

1

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

20

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

136

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

324

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

30

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

18

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

110

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

160

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

72

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

30

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

60

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

240

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

36

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

43.2

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

216

-

-

... More
od118418/2019_2020 : Providing and fixing vitreous china under counter wash basin of approved & make including one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia & rubber plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap,CP brass 15mm angle & valve,complete including CI/MS brackets duly painted, nuts, washers, etc. complete,cost and conveyance of & all materials labour charges ,lead, lift necessary wall cutting / chasing and making good the & walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels. (Model & no:Hindware 10065/Cera S2030103SN+ Hindware F280001/Cera F1015101CH+ Hindware F860010/Cera & F80501010CH+ Hindware F850072/Cera F8060301CH+ Hindware F280004/Cera F8040204CH or equivalent)

22

-

-

... More
od118419/2019_2020 : Providing & fixing star white vitreous china flat back urinal with CP brass flush valve & auto closing system with built in control cock and wall flange of approved size with all accessories to & provide satisfactory functioning including cost and conveyance of all materials, labour charges ,lead, lift & necessary wall cutting / chasing and making good the walls,floors,slab, as required for urinal flushing etc & complete, testing and commissioning to the satisfaction of Engineer in charge at all levels. (Model:Cera & S4020112SN/Hindware 60002 + Hindware F850020 or equivalent).

10

-

-

... More
od118420/2019_2020 : Providing and fixing of star white vitreous china urinal division plate of approved & quality and make with fittings/fastener including cutting and making good the walls,floors,slab ,cost and & conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by the Engineer in & charge at all levels.(Model:Hindware catalogue no: F61001/Cera S4090101SN or equivalent)

10

-

-

... More
od118421/2019_2020 : Providing and fixing CP brass body bib cock etc. complete including cost and & conveyance of all materials labour charges ,lead, lift,including cutting and making good the & walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels. & (Model:Hindware F280002CP/Cera F1015151CH or equivalent)

22

-

-

... More
od118422/2019_2020 : Providing and fixing C.P. brass concealed stop cock (control valve) of standard design & and of approved make conforming to IS:8931 etc. including cost and conveyance of all materials, labour & charges, lead,lift, necessary wall cutting / chasing and making good the walls,floor,slab etc complete, testing & and commissioning to the satisfaction of Engineer in charge at all levels.(Model-Hindware & F280027+F850096/Cera F2002362CH or equivalent

19

-

-

... More
od118423/2019_2020 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade & floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete & as directed by the directed by the Engineer in Charge at all levels

26

-

-

... More
od118424/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame & with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour & charges, sundries etc complete as directed by the Engineer in charge at all levels.75mm dia

5

-

-

... More
od118425/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame & with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour & charges, sundries etc complete as directed by the Engineer in charge at all levels.110 mm dia

5

-

-

... More
od118426/2019_2020 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin , & one pair mounting brackets,one number pillar cock & all other related fittings like bottle trap ,angle & cock,waste coupling, etc,one number EWC & Cistern complete with fittings & seat cover, one no. hinged rail & 76cm & 4nos. of grab rails 60cm etc designed for people with special needs comes with as per manufactures & specification including cutting and making good the walls and floors wherever required as per drawing and & as directed by Engineer in charge. (Model no: Hindware (70002+ Flora F280001)/Cera & (S1012135+B1520118+S2040101+S2090102+F9030451+B2210106+B2210108+ F1015101CH ) or equivalent)

1

-

-

... More
od118429/2019_2020 : Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-charge

15

-

-

... More
od118430/2019_2020 : Providing and fixing 110mm dia PVC vent cowl to pipe already fixed as directed by & Engineer-in-charge at all levels. 110mm dia

2

-

-

... More
od118432/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall & 80 mm nominal outer dia pipes

6

-

-

... More
od118433/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall & 65 mm nominal outer dia pipes

54

-

-

... More
od118434/2019_2020 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200mm dia 6 Kgf/cm2

12

-

-

... More
od118435/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance & of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 40 mm

2

-

-

... More
od118436/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance & of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mm

4

-

-

... More
od118437/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 65mm

5

-

-

... More
od118438/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 80mm

5

-

-

... More
od118439/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 100mm

5

-

-

... More
od118440/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 200mm

2

-

-

... More
od118441/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 65mm

5

-

-

... More
od118442/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 100mm

5

-

-

... More
od118443/2019_2020 : Providing and fixing 75mm dia PVC vent cowl to pipe already fixed as directed by & Engineer-in-charge at all levels. 75mm dia

4

-

-

... More
od118444/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm Y type strainer

2

-

-

... More
od118445/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 40mm Y type strainer

2

-

-

... More
od118446/2019_2020 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet (Fabricated), surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

2

-

-

... More
od118447/2019_2020 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 160 mm dia 6 Kgf/cm2 - External work- Exposed on wall

6

-

-

... More
od118449/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 150mm

2

-

-

... More
od118450/2019_2020 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber fittings etc. ( The tail pieces if required will be paid separately): 50 mm dia nominal bore

1

-

-

... More
od118451/2019_2020 : Supplying, fixing and commissioning of centrifugal pump of CI construction, bronze & impeller complete with motor,working with 415 V, 3 pH, 50 Hz including base plate foundation bolts, nuts, & pressure gauge, priming arrangements and all accessories. Capacity : 10 cum/hr, Head : 44 metre

4

-

-

... More
od118541/2019_2020 : Providing and fixing CI Y type strainer 65mm dia rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge

2

-

-

... More
od118582/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 150mm

5

-

-

... More
od118583/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length & including cost and conveyance of all materials,labour charges,making good the walls etc complete as & directed by the Engineer in Charge. 200mm

2

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

296

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

7

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

2280

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1640.2

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

1035

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

120

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

80

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

60

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

14

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

14

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

1

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

93

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

124

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).

56

-

-

... More
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

19

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

1

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

230

-

-

... More
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.

93

-

-

... More
1.47 : Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

45

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

359

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

24

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

56

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

138

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

18

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

10

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

126

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

36

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

12

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

6

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

282

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

12

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

84

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

6

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.

10

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

6

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

30

-

-

... More
od118056/2019_2020 : Supply installation, testing and commissioning of DOL starter in sheet steel enclosure upto 5 HP , 3PHASE motor including auxilliary contactors, capacitor , and all necessary accessories as required complete.

4

-

-

... More
od118057/2019_2020 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Crompton Exhaust or equivalant approved make)

24

-

-

... More
od118058/2019_2020 : Supply of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make Crompton-Institutional ceiling fan or equivalent approved make).

93

-

-

... More
od118059/2019_2020 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

4

-

-

... More
od118060/2019_2020 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 20+/-2 Watts,lumen output of luminaire greater than 1800, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 90lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Philips BN021C LED20S PSU NW GR or Wipro LL20-221-XXX-60-XX or Crompton Greaves DMLN1LT16+LT16 or equivalent approved make

85

-

-

... More
od118061/2019_2020 : METERING KIOSK- ACADEMIC BLOCK Supply, installation, testing and commissioning of KSEB metering panel, suitable for accomodating CT operated TOD meter and consisting of 3 nos. of 125 A cutout with HRC fuse, neutral link, 125A FP MCCB isolator in separate chamber,inter connections etc. as required, and necessary supports to be fabricated out of 14 SWG CRCA sheet with locable door with sealing facility having glass window for energymeter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required .The panel shall be with all accessories as per drawing & specification.

1

-

-

... More
od118063/2019_2020 : Providing and fixing 3.15mm Cu (10 SWG) & Cu wire on surface or in recess for connections etc. as required.

288

-

-

... More
od118064/2019_2020 : Supplying and laying 3.15mm Cu (10 SWG) & Copper wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

120

-

-

... More
od118065/2019_2020 : MSB-ACADEMIC - Supply, installation, testing and commissioning of LT Switch Board (Main Panel), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, wall / floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction. & Instruments & RYB Indicating lamps LED type -6 Nos. & 4A SP MCB-6 Nos & (0-500)V Class 1 with 90 deg defl. Scale-2 Nos & (0-100)A Class 1 with 90 deg defl. Scale -3 Nos & (0-125)A Class 1 with 90 deg defl. Scale -3 Nos & Voltmeter selector switch -2 Nos & 100/5 A 5 VA Class 1 CTs -3 Nos & 125/5 A 5 VA Class 1 CTs -3 Nos & ON/OFF/TRIP INDICATION LAMP -1Nos & ON/OFF INDICATION LAMP -1Nos & Digital multifunction meter to read V,A.Hz,PF,kWH -2 Nos & surge protection device (type1+2)-1Nos & Incomer & 100A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -1 Nos & 125A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -1 Nos & 125A TPN busbar chamber with Aluminium busbar & 125A FP BUS COUPLER(with mechanical interlock facility)-1 Nos & Out goings & 63A TPN Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -4 Nos & 40A TPN Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25KA) -2 Nos & 40A TPN MCCB ISOLATOR-1Nos & The panel shall be Top Entry/Exit and suitable for termination of cable system as per SLD and technical specification

1

-

-

... More
od118066/2019_2020 : Supply, Installation, Testing & Commissioning of 63 A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

1

-

-

... More
od118067/2019_2020 : Supply, installation, testing and commissioning of CO2 Liner heat detection/trace tube PANEL/modular FLOODING SYSTEM FOR ELECTRICAL PANELS-MSB ACADEMIC consisting of CO2 cylinders with weight calculated on the basis of volume of single largest compartment within the panel. UL listed trace tube of required design length, for the 9 L cylinder (One number), also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessories of complete functionality of system, complete as required as per the technical specification.

1

-

-

... More
od118068/2019_2020 : Supply of IP66 streetlight luminaire made of die cast aluminium along with driver,system wattage of 30+/-2 Watts,lumen output of luminaire greater than 3000 lumens, power factor & 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 95 lumen/watt ,wth suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Wipro LR02- 331-XXX-57-XX or other approved equivalent makes)

10

-

-

... More
od118071/2019_2020 : Earthing with C.I. earth pipe 4 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)

17

-

-

... More
od118072/2019_2020 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 10+/-2 Watts,lumen output of luminaire greater than 800, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 90lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Wipro LL20-121-XXX-60-XX or Crompton Greaves DMLN1LT16+LT8 or equivalent approved make

20

-

-

... More
od118073/2019_2020 : Providing and fixing 25mm X 6mm GI & GI strip on surface or in recess for connections etc. as required.

24

-

-

... More
od118074/2019_2020 : Supplying and laying 25mm X 6mm GI & G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

144

-

-

... More
od118075/2019_2020 : Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,,system wattage of 40+/-4 Watts(2x20 watts),lumen output of luminaire greater than 3600 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 90lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro WIO922208 + 2 Nos. of 18W LED Tube Light or Crompton Greaves IGP132LT8-16+LT8-20

125

-

-

... More
od118076/2019_2020 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole

2

-

-

... More
od118078/2019_2020 : Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable as required.

10

-

-

... More
od118079/2019_2020 : Supply of following 4C 2.5 Sq.mm Cu & size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

48

-

-

... More
od118080/2019_2020 : Supply of following 3C 4 Sq.mm Cu & size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

48

-

-

... More
od118081/2019_2020 : Supply of following 4C 6 Sq.mm Al & size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

180

-

-

... More
od118082/2019_2020 : Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.

1

-

-

... More
od118084/2019_2020 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

1

-

-

... More
od118087/2019_2020 : Supply and fixing of following 4 pole 25 amps. (415 Volts),100mA sensitivity. & rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required &

4

-

-

... More
od118089/2019_2020 : Supply of following 4C 35 Sq.mm Al & size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

72

-

-

... More
od118090/2019_2020 : Supply and fixing of following 4 pole 25 amps. (415 Volts), 30mA sensitivity. & rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

4

-

-

... More
od118091/2019_2020 : Supplying and making end termination with brass compression gland and copper lugs for following 4C 2.5 Sq.mm Cu & size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

8

-

-

... More
od118094/2019_2020 : Supplying and making end termination with brass compression gland and copper lugs for following 3C 4 Sq.mm Cu & size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

8

-

-

... More
od118095/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following 4C 6 Sq.mm Al & size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

14

-

-

... More
od118097/2019_2020 : Supplying and installing following 150 mm width X 50 mm depth X 1.6 mm thickness & size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

40

-

-

... More
od118098/2019_2020 : Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke & Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

0.25

-

-

... More
od118099/2019_2020 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required &

100

-

-

... More
od118223/2019_2020 : Supply of following 4C 16 Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. &

156

-

-

... More
od118225/2019_2020 : Supply of following 3.5 C 120 Sq.mm Al & size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

60

-

-

... More
od118227/2019_2020 : Supply and fixing of following 4 pole 40 amps. (415 Volts), 100mA sensitivity. & rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

1

-

-

... More
od118228/2019_2020 : Supplying and fixing of following 6 way (8 + 18), Double door & ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

3

-

-

... More
od118231/2019_2020 : Supplying and fixing following 8 way (8 + 24), Double door & way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

4

-

-

... More
od118232/2019_2020 : Providing and laying hot dipped galvanized steel tape 30 mm X3 mm from earth electrode directly in ground as required.

170

-

-

... More
od118233/2019_2020 : Providing and fixing of test joint suitable for hot dipped galvanized steel tape 30 mm x 3mm and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.

10

-

-

... More
od118234/2019_2020 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

180

-

-

... More
od118235/2019_2020 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

170

-

-

... More
od184604/2019_2020 : Supplying and fixing 6 way (8 + 18), Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

4

-

-

... More
od185163/2019_2020 : Supply and fixing of 2 pole 25 amps. (240 Volts), 30mA sensitivity. & rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

1

-

-

... More
od185165/2019_2020 : Supply installation, testing and commissioning of FASD starter in sheet steel enclosure for 15 HP , 3 PHASE motor including auxilliary contactors, capacitor , and all necessary accessories as required complete.

1

-

-

... More
od185166/2019_2020 : 50 KVA DG & Supply, Installation, Testing and Commissioning of 50 kVA prime rated outdoor D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable breaker etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 50 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. & Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous ooperation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be inclusive of all the civil work including RCC foundation. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
od185169/2019_2020 : Supplying and installing following 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

10

-

-

... More
od185170/2019_2020 : Supplying and making end termination with brass compression gland and aluminum lugs for following 2C 6sqmm Al size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.

2

-

-

... More
od185171/2019_2020 : Supply of following 2C 6 sqmm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

15

-

-

... More
od185173/2019_2020 : Supplying and laying 25mm X 3mm Cu strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt & spring washer spaced at 50mm)

10

-

-

... More
od185174/2019_2020 : Providing and fixing 25mm X 3mm Cu & Cu strip on surface or in recess for connections etc. as required.

10

-

-

... More
od98543/2019_2020 : Supply installation Testing and commissioning of Conventional type Manual Call Point Resettable type via Special Key Interconnecting to loop cable as required as per the technical specification.

7

-

-

... More
od98544/2019_2020 : Supply and installation of glow signage (photoluminescent) such as Fire Duct/Fire Lift/Staircase signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

15

-

-

... More
od98546/2019_2020 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: Monoblock Pump rated for 900lpm, 40 m head C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.M.S. fabricated common base plate, foundation bolts, anti vibration pads, control cabling and accessories etc. and complete in all respect as required for automatic operation of pump using pressure switches as per the technical specification.

1

-

-

... More
od98548/2019_2020 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 - 14 Kg ) range, 3/8 ; BSP bottom entry, 6 dial weather proof with stainless steel internals including fittings etc. complete as required as per technical specification

1

-

-

... More
od98549/2019_2020 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2006 with ISI mark.

11

-

-

... More
od98550/2019_2020 : Providing, installing, testing and commissioning of conventional type Hooter with a minimum sound level of 80DB at 10 Ft Distance,interconnecting to loop cable complete as required as per the technical specification.

7

-

-

... More
od98551/2019_2020 : Supply and installation of glow signage (photoluminescent) FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. and complete as required as per the technical specification.

2

-

-

... More
od98552/2019_2020 : Supply and installation of glow signage (photo luminescent)of FIRE ORDER of standard size (500*800 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

4

-

-

... More
od98553/2019_2020 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4 BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required with necessary control cablings & wirings for successful system operation as per technical specification.

1

-

-

... More
od98554/2019_2020 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification.

1

-

-

... More
od98555/2019_2020 : Supply, Installation, Testing & Commissioning of Conventional Type, 4 zone manual operated Fire Alarm Panel including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module etc.The panel shall have Keypad operation, L C D unit to indicate Fire / Fault Signal of individual unit, etc complete in all respects as required as per the technical specification. The item shall also include 24 Volts sealed lead acid battery sufficient for 24 hrs back up with battery charger.

1

-

-

... More
od98558/2019_2020 : Supply and installation of glow signage (photo luminescent) such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

8

-

-

... More
od98559/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including welding fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 100 mm dia

51

-

-

... More
od98560/2019_2020 : Supply, installation, testing and commissioning of wall mounted talk back unit including all necessary accessories complete as required as per the technical specification..

4

-

-

... More
od98561/2019_2020 : Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

37

-

-

... More
od98563/2019_2020 : Supply and fixing of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwiched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification.

4

-

-

... More
od98564/2019_2020 : Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including welding fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 80 mm dia

3

-

-

... More
od98565/2019_2020 : Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including welding fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including & excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as & per IS10221, refilling the trench etc. of following sizes complete as required as per technical specification & 100mm dia

7

-

-

... More
od98566/2019_2020 : Supply, installation, testing and commissioning of public address and talk back system consisting of multiple zone public address cum talkback console with mike and selector. multiple channel talk back master control panel with 2x16 character LCD display,power supply, battery charger, battery housing, 80 W PA & mic, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier (min 80W) and suitable capacity battery (min 12V) all assembled in a cabinet and meeting the technical specifications. The rate shall include the cost of all the necessary accessories as required for the operation of the system.

1

-

-

... More
od98568/2019_2020 : Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as per IS10221, refilling the trench etc. of following sizes complete as required as per technical specification 80mm dia

2

-

-

... More
od98569/2019_2020 : Supply and laying of 2x 1.5sq.mm armored Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above ground as per technical specification

930

-

-

... More
od98570/2019_2020 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

52

-

-

... More
od98571/2019_2020 : Supply, installation, testing and commissioning of dual plate non-return valve of following sizes having PN 16 pressure rating complete with rubber gasket, GI bolts, nuts, washers etc. as required as per technical specification and confirming to API-594- 100 mm dia

2

-

-

... More
od98573/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, SS disc nitrile rubber sheet,O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification.- 100 mm dia

3

-

-

... More
od98574/2019_2020 : Supply,installation,testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,Chain etc as per technical specification

5

-

-

... More
od98575/2019_2020 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585. (b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe

4

-

-

... More
od98576/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required as per technical specification

10

-

-

... More
od98577/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required.

5

-

-

... More
od98578/2019_2020 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.

5

-

-

... More
od98579/2019_2020 : Supply, installation, testing and commissioning of Fire brigade collective breaching with 2 nos. of 100 mm flanged out let connection and built in check valves complete as required as per technical specification

1

-

-

... More
od98580/2019_2020 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia complete as required as per the technical specification

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.