KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date19 Apr 2022
Closing Date9 May 2022
Tender Amount₹ 28,71,88,544 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

5

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

2895.26

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1647.68

-

-

... More
50.2.3.1 : Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

444

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering,for all leads and lifts as per direction of site Engineer-in-charge

284.73

-

-

... More
50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, for all leads and lifts as per direction of site Engineer-in-charge.

3780

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m

3652.26

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

425.19

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

0.51

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

435.01

-

-

... More
PILE WORK

-

-

-

... More
od309462/2021_2022 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).cap).(Note: Minimum cement contentconsidered in M-30 is @ 400 Kg/cum as per IS 2911 : 2010 )600 mm dia piles

11251.8

-

-

... More
od309431/2021_2022 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap)(Note: Minimum cement content considered in M-30 is @ 400 Kg/cum as per IS 2911 : 2010 )900 mm dia piles

3833.25

-

-

... More
20.6.2.1 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test

2

-

-

... More
20.6.2.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test

5.88

-

-

... More
CONCRETE WORK

-

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

72.95

-

-

... More
4.17 : Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

225

-

-

... More
od309432/2021_2022 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .Minimum cement content considered in this item is @ 340 kg/cum. All work upto plinth level.

1232.3

-

-

... More
od310475/2021_2022 : Providing Steel Liner of approved thickness for Steining of pile including Fabricating and Setting out as per Detailed Drawing including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as directed by Engineer in charge.

74894.68

-

-

... More
od309435/2021_2022 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .Minimum cement content considered in this item is @ 340 kg/cum All work upto floor V level.

1710.74

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1634.19

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

907.37

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

5665.31

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

6627.22

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

3319.76

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

436.33

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

5.5

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1029.2

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

13.5

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

5370

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

10.62

-

-

... More
5.18.1 : Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand ) etc. complete excluding plastering of the jambs, sills and soffits.50 mm thick

73

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

606411.87

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

261719.86

-

-

... More
MASONRY WORK

-

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

312.62

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

986.07

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

40.7

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

33.48

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

79.82

-

-

... More
JOINERY WORK

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

3577.21

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

2000.5

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

11.88

-

-

... More
od311078/2021_2022 : Providing and fixing glazing with 12mm toughened glass in existing aluminium frame work with EPDM rubber / neoprene gasket.The joints between glass panels and gaps at the perimeter of the assembly tobe filled with non staining weather sealant, so as to make the entire system fully water proof dust proof;etc. complete as per the architectural drawings and the directions of Engineer-in-charge

65.17

-

-

... More
od309429/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item)With Toughened glass panes of 6 mm thickness

57.42

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

413.24

-

-

... More
5.28 : Providing and fixing in position 12 mm thick bitumen impregnated fibre board /Polymeric expansion filler board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints.

459

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

563

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

736.95

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

268.4

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

22

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

4

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately)Second class teak wood35 mm thick shutters

188.64

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

113.18

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

11.88

-

-

... More
9.14 : Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)

188.64

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

83.81

-

-

... More
9.24.1 : Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square

21.6

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

638

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

29

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

122

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

122

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

122

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

154

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

67

-

-

... More
9.102 : Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.

235

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

339

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

86.4

-

-

... More
9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710

221.54

-

-

... More
9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

119.3

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

3

-

-

... More
9.149 : Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete.

235

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

59.2

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

12.1

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

5.18

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

18

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

5

-

-

... More
od301090/2021_2022 : Providing and fixing steel (white power coated) crescent lock for uPVC /aluminum sliding window/ door with necessary screws etc. complete.

452

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

9

-

-

... More
STEEL WORK

-

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

5183.61

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

164.16

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

7576.93

-

-

... More
10.27.2 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm

1272

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1940.76

-

-

... More
FLOORING WORK

-

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

72.5

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

11.25

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

4230

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

503.15

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

342.84

-

-

... More
od309436/2021_2022 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

133.59

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.

578.42

-

-

... More
CEILING WORK

-

-

-

... More
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board.

328.9

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

161.1

-

-

... More
12.52.3 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.

83.87

-

-

... More
12.52.4 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plaster board having glass fibre conforming to IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of 0.79, with 50 mm resin bonded glass wool backing.

73.28

-

-

... More
26.27.2 : Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge.With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)

302.86

-

-

... More
FINISHING WORK

-

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

15739.34

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

636.02

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

5503.21

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

16814.44

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

61.76

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

5023.36

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

377.07

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

16485.54

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

328.9

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

490.46

-

-

... More
WATER PROOFING WORK

-

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

58.59

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

38.25

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.

383.58

-

-

... More
od302242/2021_2022 : Providing and fixing EPDM Waterproofing membrane for Vertical surface including membrane protection boards with high strength having one cuspated structure, light weigt and flexible compressive strength of 20000 kg/m2, the boards shall be placed spot bonded over the EPDM membrane with adhesive as sacrificial layer between back fill and the membrane also to avoid the membrane to get punchered during laying from any sharp edges material. Providing and laying specially formulated single-ply Grey-Black Dusted 45 mil (1.14 mm) EPDM (Ethylene, Propylene, Diene Terpolymer) non-reinforced with factory applied tape of 75mm on one side of the roll. The membrane mush have Grey-Black dusted surface with the roll size 20x100 Roll with Factory applied tape only. laying Grey Black Dusted non-reinforced 45 mil membrane overlapping the left horizontal membrane on the PCC to the vertical Peripheral walls as shown in the drawing after removing any sharp material like reinforcement steel etc from the surface by sealing the membrane with 75mm wide secure tape with sheet to the extended portion of the horizontal membrane as per the manufacturers specifications in all complete. The membrane shall be temporary mechanically fixed every 3-4 meters to hold the membrane if required and to be fully adhered with Bonding Adhesive applying on both side on retaining wall and on the membrane as well to make it fully bonded with the surface. At the top end on the vertical side the membrane is fixed with aluminium flashing, HP fastener and sealed with Sealant Water cutoff mastic as per the manufacturers specifications all complete and as directed by the Engineer in charge at all levels .The above work shall be carried out by an agency having sufficient experience in concerned work and should ensure a guarantee for any defective installation, material composition and water tightness for a period of 10 years from the date of completion of the said work .only skilled and experienced persons shall be employed for this purpose.

156

-

-

... More
od302243/2021_2022 : Providing and fixing EPDM Waterproofing membrane for Horizontal surface including laying geo-textile mesh of 150 gsm over the prepared sub-base, as the separation layer between the pcc and the membrane also to avoid the membrane to get punched during laying from any sharp edges material, now over the geo textile mesh providing and laying specially formulated single-ply Grey-Black Dusted 45 mil (1.14 mm) EPDM (Ethylene, Propylene, Diene Terpolymer) non-reinforced with factory applied tape of 75mm on one side of the roll. The membrane mush have Grey-Black dusted surface with the roll size 20x100 Roll with Factory applied tape only. Membrane shall be laid loose. Over lap joint shall be made using Secure Tape technology . Membrane shall have minimum of 75mm side with factory applied tape on the one side of the membrane and end laps with loose which shall be sealed with highly formulated loosle double sided SECUR TAPE. Membrane shall be able to resist 40mtr. head pressure, with tensile strength of 11 mpa, elongation ; 465% and Tear strenght as per ASTM D624 shold be 35.0 kN/m , Die C dimensional change -0.7%. 100% UV resistance, Ozone resistance according to ASTM D1149. The membrane should have British Board Of Agreacutement [BBA] for Non-Reinforced EPDM Underground Waterproofing Systems. Membrane shall be taken 300mm . extra from the P.C.C so as to envelope on to the vertical surface . The membrane shall be covered with the geotextile of 150 gsm membrane for the protection of EPDM membrane to avoid to get membrane punctured while working further and protecting the membrane till placing of RCC slabs as per the manufacturers specifications all complete and as directed by the Engineer in charge at all levels .The above work shall be carried out by an agency having sufficient experience in concerned work and should ensure a guarantee for any defective installation, material composition and water tightness for a period of 10 years from the date of completion of the said work .only skilled and experienced persons shall be employed for this purpose.

92.8

-

-

... More
od309438/2021_2022 : Providing and fixing EPDM Waterproofing membrane for Vertical surface including membrane protection boards with high strength having one cuspated structure, light weigt and flexible compressive strength of 20000 kg/m2, the boards shall be placed spot bonded over the EPDM membrane with adhesive as sacrificial layer between back fill and the membrane also to avoid the membrane to get punchered during laying from any sharp edges material. Providing and laying specially formulated single-ply Grey-Black Dusted 45 mil (1.14 mm) EPDM (Ethylene, Propylene, Diene Terpolymer) non-reinforced with factory applied tape of 75mm on one side of the roll. The membrane mush have Grey-Black dusted surface with the roll size 20x100 Roll with Factory applied tape only. laying Grey Black Dusted non-reinforced 45 mil membrane overlapping the left horizontal membrane on the PCC to the vertical Peripheral walls as shown in the drawing after removing any sharp material like reinforcement steel etc from the surface by sealing the membrane with 75mm wide secure tape with sheet to the extended portion of the horizontal membrane as per the manufacturers specifications in all complete. The membrane shall be temporary mechanically fixed every 3-4 meters to hold the membrane if required and to be fully adhered with Bonding Adhesive applying on both side on retaining wall and on the membrane as well to make it fully bonded with the surface. At the top end on the vertical side the membrane is fixed with aluminium flashing, HP fastener and sealed with Sealant Water cutoff mastic as per the manufacturers specifications all complete and as directed by the Engineer in charge at all levels .The above work shall be carried out by an agency having sufficient experience in concerned work and should ensure a guarantee for any defective installation, material composition and water tightness for a period of 10 years from the date of completion of the said work .only skilled and experienced persons shall be employed for this purpose.

185.36

-

-

... More
od309439/2021_2022 : Providing and fixing EPDM Waterproofing membrane for Horizontal surface including laying geo-textile mesh of 150 gsm over the prepared sub-base, as the separation layer between the pcc and the membrane also to avoid the membrane to get punched during laying from any sharp edges material, now over the geo textile mesh providing and laying specially formulated single-ply Grey-Black Dusted 45 mil (1.14 mm) EPDM (Ethylene, Propylene, Diene Terpolymer) non-reinforced with factory applied tape of 75mm on one side of the roll. The membrane mush have Grey-Black dusted surface with the roll size 20x100 Roll with Factory applied tape only. Membrane shall be laid loose. Over lap joint shall be made using Secure Tape technology . Membrane shall have minimum of 75mm side with factory applied tape on the one side of the membrane and end laps with loose which shall be sealed with highly formulated loosle double sided SECUR TAPE. Membrane shall be able to resist 40mtr. head pressure, with tensile strength of 11 mpa, elongation 465% and Tear strenght as per ASTM D624 shold be 35.0 kN/m , Die C dimensional change -0.7%. 100% UV resistance, Ozone resistance according to ASTM D1149. The membrane should have British Board Of Agreacutement [BBA] for Non-Reinforced EPDM Underground Waterproofing Systems. Membrane shall be taken 300mm . extra from the P.C.C so as to envelope on to the vertical surface . The membrane shall be covered with the geotextile of 150 gsm membrane for the protection of EPDM membrane to avoid to get membrane punctured while working further and protecting the membrane till placing of RCC slabs as per the manufacturers specifications all complete and as directed by the Engineer in charge at all levels .The above work shall be carried out by an agency having sufficient experience in concerned work and should ensure a guarantee for any defective installation, material composition and water tightness for a period of 10 years from the date of completion of the said work .only skilled and experienced persons shall be employed for this purpose.

142.93

-

-

... More
ROOFING WORK

-

-

-

... More
50.12.2.1 : Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required.

74

-

-

... More
MISCELLANEOUS WORK

-

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)Complete as per design

40

-

-

... More
21.7.2 : Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Powder coated aluminium sheet 2.5 mm thick ( minimum thickness of powder coating 50 micron)

84

-

-

... More
od301088/2021_2022 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

8

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

2

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

2

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

2

-

-

... More
od302227/2021_2022 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge 110mm OD(6 kg/cm2)

30

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

337

-

-

... More
od302228/2021_2022 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

2

-

-

... More
od309440/2021_2022 : Disposal/stacking of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

1029

-

-

... More
SANITARY INSTALLATIONS AND FIXTURES

-

-

-

... More
17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

28

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

30

-

-

... More
18.50.1 : Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore

30

-

-

... More
od310351/2021_2022 : Providing and fixing white vitreous china under counter wash basin of approved makeincluding one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia rubberplugs 32 mm dia CP brass waste coupling ,complete including CI/MS brackets duly painted, nuts, washers,etc. complete,cost and conveyance of all materials labour charges ,lead, lift necessary wall cutting / chasingand making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer incharge at all levels. Models Cera S2030104SN/Hindware 10049-SW or equivalent as instructed by theEngineer in charge

14

-

-

... More
17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap

13

-

-

... More
17.22A : Providing and fixing CP Brass 32mm size Bottle trap of approved quality & make and as per the direction of Engineer in charge.

29

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

115

-

-

... More
od310353/2021_2022 : Providing and fixing white vitreous urinal division plate of approved quality as per therequirements of the Engineer in charge at all levels. Models Hindware 61001-SW/Cera S4090101SN orequivalent as required by the Engineer in Charge.

12

-

-

... More
od310355/2021_2022 : Providing and fixing white vitreous china flat back urinal basin with urinal flush valve with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Models Hindware 60002+F850020/Cera S4020112SN+F9020203CH or equivalent as instructed by the Engineer-in-charge

12

-

-

... More
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm

24

-

-

... More
od310364/2021_2022 : Providing and fixing CP brass swan neck sink cock of approved make and quality including cost and conveyance of all materials,labour charges,lead,taxes etc complete to the satisfaction of Engineer in Charge at all levels.(The purchase price(inclusive of all taxes) of CP brass swan neck sink cock and any deviation plus or minus in the purchase price of approved make will be adjusted (will be paid extra or deducted ) while making payment to the contractor).

24

-

-

... More
od310369/2021_2022 : Providing and fixing CP Brass robe hook as per the instructions of the Engineer in charge. Models Jaquar ACN CHR1191N/Kerovit KA930002 or equivalent as instructed by Engineer in charge

28

-

-

... More
od310372/2021_2022 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin one pair mounting brackets,one number pillar cock all other related fittings like waste coupling,one number EWC Cistern complete with fittings seat cover, one no. hinged rail 76cm 4nos. ofgrab rails 60cm etc designed for people with special needs comes with asper manufactures specification including cutting and making good the walls and floors whereverrequired as per drawing and as directed by Engineer in charge. (Model no: Hindware 70002 MatrixSet/Cera Cruse Set or equivalent) as instructed by the Engineer in Charge

2

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

27

-

-

... More
od310381/2021_2022 : Providing and fixing floor trap 110 mm dia (gratings exposed)with cockroach trap (multi trap), S304 grade exposed floor grating with multitrap including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

42

-

-

... More
od310382/2021_2022 : Providing and fixing floor trap 110 mm dia (gratings concealed)with cockroach trap (multi trap), S304 grade concealed floor grating with multitrap including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

2

-

-

... More
od310384/2021_2022 : :Providing and fixing Cleanout with Spigot, with SS 304 Square Frame Round Frame with Flat Round Cover with Rubber Seal SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels. 75mm dia

5

-

-

... More
od310385/2021_2022 : :Providing and fixing Cleanout with Spigot, with SS 304 Square Frame Round Frame with Flat Round Cover with Rubber Seal SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.110mm dia

5

-

-

... More
od310388/2021_2022 : Providing and fixing CP brass stop cock including concealed and exposed parts of approved quality : 15 mm nominal bore Model- Hindware-(F280027CP+F850096CP) or equivalent as per the instruction of the Engineer in charge

19

-

-

... More
WATER SUPPLY ARRANGEMENTS

-

-

-

... More
50.18.8.1.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2

12

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

40

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

185

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

281

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

26

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

126

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

48

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

89

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

83

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

51

-

-

... More
od310356/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot cold water supply, including all CPVC plain brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 65 mm dia pipes

234

-

-

... More
od310358/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot cold water supply, including all CPVC plain brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 80 mm dia

102

-

-

... More
od310359/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot cold water supply, including all CPVC plain brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 100 mm dia Pipes

99

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

154

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

18

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

5

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

11

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

10

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

3

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

3

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

1

-

-

... More
18.31.1.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II

1

-

-

... More
18.31.3.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):150 mm diameterClass II

2

-

-

... More
od310389/2021_2022 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15x15 cm and weighing not less than 440 grams.

26

-

-

... More
od310390/2021_2022 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm dia

4

-

-

... More
SANITARY ARRANGEMENT

-

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

12

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

24

-

-

... More
od310354/2021_2022 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame (medium duty) : With bricks.Class designation 75

20

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
od310357/2021_2022 : Supplying, fixing, testing and commissioning to the satisfaction of Engineer in charge of PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and water tight C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge

12

-

-

... More
od310360/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - Internal work- Exposed on wall

158

-

-

... More
od310361/2021_2022 : Supplying and fixing GI threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.

72

-

-

... More
od310362/2021_2022 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling testing of joints complete as per direction of Engineer in Charge. 160 mm dia 6 Kgf/cm2

468

-

-

... More
od310363/2021_2022 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling testing of joints complete as per direction of Engineer in Charge. 110 mm dia 6 Kgf/cm2

121

-

-

... More
od310365/2021_2022 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/cm2

60

-

-

... More
od310366/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

18

-

-

... More
od310367/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

146

-

-

... More
od310370/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

33

-

-

... More
od310371/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

544

-

-

... More
od310374/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 kgf/cm2

101

-

-

... More
od310375/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110mm pipe 6 kgf/cm2

85

-

-

... More
PUMPS, FILTERS AND ACCESSORIES

-

-

-

... More
od310349/2021_2022 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels Capacity: 4.1-0.5 lps , Head : 10-32 m

4

-

-

... More
od310350/2021_2022 : Supplying and fixing Pressure Guage including cost and conveyance of all materials

2

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

4

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

2

-

-

... More
od310352/2021_2022 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mm

4

-

-

... More
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore

1

-

-

... More
18.61.1 : Providing and fixing C.I dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :80 mm dia

1

-

-

... More
2.10.1.3 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

20

-

-

... More
od310368/2021_2022 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 450 mm dia RCC pipes.

6

-

-

... More
od310373/2021_2022 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 300 mm dia RCC pipes.

6

-

-

... More
od310376/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

2

-

-

... More
od310377/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

1

-

-

... More
od310378/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mm

4

-

-

... More
od310379/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mm

1

-

-

... More
od310380/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 80mm

1

-

-

... More
od310383/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 80mm

3

-

-

... More
od310386/2021_2022 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm

2

-

-

... More
od310387/2021_2022 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm

4

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

10000

-

-

... More
HT EQUIPMENT & DG SET

-

-

-

... More
od292647/2021_2022 : 11kV Outdoor RMU panel (Extensible Type) - Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit outdoor type (IP-54) with 2 nos motorised Load break switch as incomer and 1 no motorized VCB(fully rated earth switch) with fully encapsulated vacuum interrupter panel as outgoings, 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a existing foundation. The RMU must be both side extensible type .The rate quoted shall be inclusive mounting accessories, hoisting to its location,assembling of units,lining up, bolting the units and checking all control wiring complete as per single line diagram & technical specification.The LBS & VCB shall been eabled with VIPS and LBS shall be equipped with Fault passage indicator.

1

-

-

... More
od292690/2021_2022 : TRANSFORMER - 400 kVA 11kV/433V Cast Resin (Dry type) Laser Scribed UNITIZED SUBSTATION- 400 KVA DRY TYPE Design, fabrication, Supply, installation, testing and commissioning of indoor type Unitized Substation with transformer of rating 400 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram & technical specification. HT Chamber 630A 21kA 11kV LBS with earth switch Transformer Compartment 400 kVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 10% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 100/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel as per SLD & LT Chamber: Suitable for terminating 2 RUN x 3.5C x 300 sq.mm cable. ;

1

-

-

... More
od292704/2021_2022 : 200 kVA DIESEL GENERATOR "Supply, Installation, Testing and Commissioning of 200 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 200 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery

1

-

-

... More
LT PANEL BOARDS

-

-

-

... More
od292740/2021_2022 : SUB MAIN DISTRIBUTION BOARD 1 ;Supply, erection, testing and commissioning of wall mounting type, double door 3 phase 8 way sub main distribution board of approved make complying IEC 61439 ,made of 16 SWG CRCA sheet metal ,IP43 and quality with cable allay ,on bottom as well as sides,metering extension box ,corner boxes etc including busbar, neutral link and DIN bar with all accessories etc complete with all connections and inter-connections as shown in the schematic drawing,for complete installation as instructed by engineer in charge/consultant. ;Incomer - 250A TP 25kA TM based MCCB ;Bus bar - 250 A 415V, 25 kA best conductivity CU TPN bus bar ;Outgoings ;125 A TP 25kA TM Based MCCB - 1 nos ;80 A TP 25kA TM Based MCCB - 1 nos ;63A TP 25kA TM Based MCCB - 2 nos ;40A TP 25kA TM Based MCCB - 2 nos ;25A TP 25kA TM Based MCCB - 2 nos ;Supply, Installation, testing and commisioning.

1

-

-

... More
od294377/2021_2022 : COMMON SERVICE PANEL ;Supply, Installation, Testing & Commissioning of LT Switch Boardcubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be lockable type as per requirements of EB.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction ;Incomer - 250A FP 36kA TM based MCCB ;Bus bar - 250 A 415V, 36 kA best conductivity Al TPN bus bar ;Instruments - 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD ;Surge Protection Device Type 1+2- 1 set ;Outgoings ;160A 25kA TP TM Based MCCB - 1 Nos. ;100A 25kA TP TM Based MCCB -5 Nos. ;63A 25kA TP TM Based MCCB Isolator - 1 No. ;Supply, Installation, testing and commisioning.

1

-

-

... More
od294398/2021_2022 : UPS SMDB /LAB Equipment ;Supply, erection, testing and commissioning of wall mounting type, double door 3 phase 8 way sub main distribution board of approved make complying IEC 61439 ,made of 16 SWG CRCA sheet metal ,IP43 and quality with cable allay ,on bottom as well as sides,metering extension box ,corner boxes etc including busbar, neutral link and DIN bar with all accessories etc complete with all connections and inter-connections as shown in the schematic drawing,for complete installation as instructed by engineer in charge/consultant. ;Incomer - 160A TP 25kA TM based MCCB ;Bus bar - 160 A 415V, 25 kA best conductivity CU TPN bus bar ;Instruments - 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches, Indication Lamps, CTs, as per SLD ;Outgoings ;80A 25kA TP TM Based MCCB - 8 Nos. ;Supply, Installation, testing and commisioning.

2

-

-

... More
od312101/2021_2022 : MAIN PANEL ;Supply, Installation, Testing & Commissioning of LT Switch Boardcubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be lockable type as per requirements of EB.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction ;Incomers ;EB Incomer 1 - 630A 36kA FP Microprocessor based MCCB with 3 O/C and 1 E/F releases. Standby low set E/F relay with CT at neutral earthing conductor & 630 A FP Power contactor - 1 Nos ;DG Incomer 1 - 320A 36kA FP Microprocessor based MCCB with 3 O/C and 1 E/F releases. Standby low set E/F relay with CT at neutral earthing conductor & 320A FP Power contactor - 1 Nos ;DG Incomer 2 - 400A 36kA FP Microprocessor based MCCB with 3 O/C and 1 E/F releases. Standby low set E/F relay with CT at neutral earthing conductor & 400A FP Power contactor - 1 Nos ;Buscoupler - 630A 36kA FP MCCB ;Bus bar - 630A 415V, 36 kA best conductivity Al TPN bus bar ;Instruments - 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Surge protection device ,Protection Relays, PLC based AMF relay & Loadmanagement with necessary interlocking arrangement as per SLD ;Surge Protection Device Type 1+2- 2 nos ;Outgoings ;250A 36kA TP + NL Microprocessor Based MCCB - 2 Nos ;200A 36kA TP + NL Microprocessor Based MCCB - 2 Nos ;160A 36kA TP + NL Microprocessor Based MCCB -7 Nos ;125A 36kA TP + NL Microprocessor Based MCCB -2 Nos ;Supply, Installation, testing and commisioning.

1

-

-

... More
od312102/2021_2022 : APFC PANEL ;80KVAR APFC PANEL Supply, Installation, Testing & Commissioning of Capacitor Panel Board , cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc., including provision for capacitor mounted inside the panel with adequate number of louvers and powder coated with approved shade and having following specific components all inter connections and following components as per drawing and technical specifications. The panel shall be of Form 3b construction ;Incomer: 200 A,25kA FP MCCB with adjustable thermal magnetic release - 1 nos Instruments 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, IPFC Relays ;as per SLD" ;Busbar 200A TPN busbar chamber with Aluminium busbar Outgoings: ; 63A, 25kA, TP MCCB with adjustable thermal magnetic release - 2 nos ; 32A, 25kA, TP MCCB with adjustable thermal magnetic release -4 nos ;25 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type)-2 No ;10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 2 Nos ;5 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 2 Nos ;25 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2 No ;10 kVAr,480 V,50 Hz heavy dutycapacitor(APP-H) with 7 % Seriesreactor -2 Nos ; 5 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2 Nos ;Control wiring required for no load compensation capacitor" ;

1

-

-

... More
od312103/2021_2022 : SUB MAIN DISTRIBUTION BOARD 2 ;Supply, erection, testing and commissioning of wall mounting type, double door 3 phase 8 way sub main distribution board of approved make complying IEC 61439 ,made of 16 SWG CRCA sheet metal ,IP43 and quality with cable allay ,on bottom as well as sides,metering extension box ,corner boxes etc including busbar, neutral link and DIN bar with all accessories etc complete with all connections and inter-connections as shown in the schematic drawing,for complete installation as instructed by engineer in charge/consultant. ;Incomer - 160A TP 25kA TM based MCCB ;Bus bar - 160 A 415V, 25 kA best conductivity CU TPN bus bar ;Outgoings ;80 A TP 25kA TM Based MCCB - 1 nos ;63 A TP 25kA TM Based MCCB - 3 nos ;40 A TP 25kA TM Based MCCB - 2 nos ;25A TP 25kA TM Based MCCB - 2 nos ;Supply, Installation, testing and commisioning.

1

-

-

... More
CABLES ,LAYING & TERMINATION

-

-

-

... More
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness Details of cost for 30 metres

50

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

75

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

171

-

-

... More
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness

52

-

-

... More
4.7.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

28

-

-

... More
4.7.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

6

-

-

... More
4.8.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.8.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.8.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
4.8.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
4.9.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cabl tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.9.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.9.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
4.9.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
4.10.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.10.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.10.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
4.10.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

30

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

30

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

30

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

939

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

12

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

294

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

72

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

25

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

563

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

30

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

20

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

14

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

2

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

22

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

2

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

4

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

14

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

16

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

4

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
od292710/2021_2022 : Supply of following 3C X 300sq.mm sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date.

613

-

-

... More
od292981/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx400sq.mm Al Cable.

36

-

-

... More
od292991/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx300sq.mm Al Cable.

36

-

-

... More
od293000/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx240sq.mm Al Cable.

18

-

-

... More
od293013/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx185sq.mm Al Cable.

42

-

-

... More
od293078/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx120sq.mm Al Cable.

216

-

-

... More
od293110/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx35sq.mm Al Cable.

216

-

-

... More
od293111/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx70sq.mm Al Cable.

42

-

-

... More
od293160/2021_2022 : Supply of 12C x 2.5 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor Control cable conforming to IS 7098 (Part 1) amended upto date.

120

-

-

... More
od293161/2021_2022 : Supply of 2C x 4 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

197

-

-

... More
od293162/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4x10sq.mm Al Cable

421

-

-

... More
od293163/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4x16sq.mm Al Cable

362

-

-

... More
od293186/2021_2022 : Supply and laying of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid / stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in meduin duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant. 1Cx50 Sq.mm Copper Flexible Cable

120

-

-

... More
od294762/2021_2022 : Supplying and making end termination with brass compression gland and CU lugs for following size of PVC insulated and PVC sheathed / XLPE CU conductor cable of 1.1 KV grade as required. 2 X 4 sq. mm

8

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

30

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

30

-

-

... More
od312308/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminum conductor power cable confirming to IS 7098 (part 1) amended up to date. ;3.5 x 150 sq.mm Al Cable

18

-

-

... More
9.1.15 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 150 sq. mm (50mm)

2

-

-

... More
od312586/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor power cable confirming to IS 7098 (part 1) ammended upto date. ;3C x 6 sq.mm Cu Cable

486

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

486

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

280

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

10

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

3360

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

6024

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

2484

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

150

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

150

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

300

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

150

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

450

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

153

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

561

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

14

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

49

-

-

... More
od292060/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in ;recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps ;modular switch, connection etc. as required.

194

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/Isolator12 way, Double door

4

-

-

... More
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door

1

-

-

... More
2.4.2 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door

2

-

-

... More
2.4.3 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door

7

-

-

... More
2.5.1 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door

1

-

-

... More
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door

3

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

228

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

25

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
2.23.4 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 14 way, Double door SPN MCBDB

4

-

-

... More
2.24.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB

1

-

-

... More
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

2

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

7

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

4

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

20

-

-

... More
od293650/2021_2022 : Supply, installation, testing and commisioning of following rating TP D curve MCB, as per IS/IEC 60898-12002 in the existing MCB HDB/VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 63A TP MCB

6

-

-

... More
od293651/2021_2022 : Supply, installation, testing and commisioning of following rating TP D curve MCB, as per IS/IEC 60898-12002 in the existing MCB HDB/VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 40A TP MCB

6

-

-

... More
od293653/2021_2022 : Supply, installation, testing and commisioning of following rating 240/415, 10kA TP C curve MCB, as per IS/IEC 60898-12002 in the existing MCB HDB/VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 63A TP MCB

2

-

-

... More
od293654/2021_2022 : Supply, installation, testing and commisioning of following rating 240/415, 10kA TP C curve MCB, as per IS/IEC 60898-12002 in the existing MCB HDB/VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. 40A TP MCB

10

-

-

... More
od312111/2021_2022 : Supplying, fixing, testing and commissioning following four pole , 415 volts , residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB ;s complete with connections, etc. as required and instructed by engineer in charge/consultant.. 25A 30mA FP RCBO

8

-

-

... More
od312112/2021_2022 : Supplying, fixing, testing and commissioning following double pole ,240 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB ;s complete with connections, etc. as required and instructed by engineer in charge/consultant.. 25A 30mA DP RCBO

4

-

-

... More
od312113/2021_2022 : Supplying, fixing, testing and commissioning following four pole , 415 volts, residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DBs complete with connections, etc. as required and instructed by engineer in charge/consultant.. 40A 100mA FP RCBO

6

-

-

... More
od312114/2021_2022 : Supplying, fixing, testing and commissioning following four pole , 415 volts , residual current circuit breaker with overload protection (RCBO) of the following rating and sensitivity current in the existing MCB SPN and TPN horizontal/vertical DB ;s complete with connections, etc. as required and instructed by engineer in charge/consultant.. ;63A 100mA FP RCBO ;

2

-

-

... More
od312115/2021_2022 : Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “D” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;Single Pole

128

-

-

... More
od312269/2021_2022 : Supply, installation, testing and commissioning of following rating 240/415, 10kA FP C curve MCB, as per IS/IEC 60898-12002 in the existing MCB HDB/VDB including all connections and interconnections as required and as instructed by engineer in charge/consultant. ;63A FP MCB

1

-

-

... More
od312270/2021_2022 : Supply, installation, testing and commissioning of following rating 240/415, 10kA FP C curve MCB, as per IS/IEC 60898-12002 in the existing MCB HDB/VDB including all connections and interconnections as required and as instructed by engineer in charge/consultant. ;100A FP MCB

3

-

-

... More
od312278/2021_2022 : Supply, installation, testing and commissioning of following rating 240/415, 10kA FP D curve MCB, as per IS/IEC 60898-12002 in the existing MCB HDB/VDB including all connections and interconnections as required and as instructed by engineer in charge/consultant. ;63A FP MCB

2

-

-

... More
od312397/2021_2022 : Supply installation ,testing & commissioning of following 160A FP MCCB ,415V 25kA isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.

2

-

-

... More
od312413/2021_2022 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN distribution board of sheet steel, dust protected, duly powder painted, inclusive of copper bus bar, common neutral link, earth bar, din bar for mounting MCCB as Incomer and MCB ;s as outgoings (but without MCCB & MCB ;s ) as required . ;8 way ,Double door

1

-

-

... More
90.11.1.13 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)

3

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od293209/2021_2022 : Supply of Integral, SMD LED, IP 65, LED Surface mounted Bulkhead fixture with System efficacy of more than 100 lm/W. Luminaire shall be made up of Die Cast Aluminium for efficient heat dissipation. Luminaire shall have Polycarbonate high transmitivity diffuser for Uniform illumination and wider light distribution. LED luminaire shall have specially design aluminum heat sink for excellent heat dissipation, good air circulations as well as very light weight. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED.The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2.5 KV internal surge protection, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Wipro Model No LW07-141-XXX-57-G1 or Equivelent approved make

10

-

-

... More
od293210/2021_2022 : Supply of Integral, SMD 2x2 LED, IP 20, 36W LED Surface mounted fixture with UGR<19 and System efficacy of more than 100lm/W and system lumen output 3600lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia / Cree / Bridgelux / Lumileds should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Complying to SELV < 60V DC standards. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Wipro Model No. CRCO10R036HP57UGG2 or equivalant

65

-

-

... More
od293211/2021_2022 : "Supply of 10W High efficient LED batten surface/wall mounted Specially designed Co-extruded channel in thermally conductive material with plastic with HET diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI >80, Temperature range-0 to 50DegC, Driver efficiency>85%, Power factor>0.9, CCT - 6500K, THD<20%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. ;Luminaire lumen ≥ 903 lumens (90 lm/W) Wipro LL20-111-XXX-65NE3 or Equivelent approved make" ;

28

-

-

... More
od293212/2021_2022 : "Supply of 20W High efficient LED batten surface/wall mounted Specially designed extruded Aluminium housing with PC diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI >80, Temperature range-0 to 50DegC, Driver efficiency>86%, Power factor>0.95, CCT - 6500K, THD<10%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. ;Luminaire lumen ≥ 2000 lumens (100 lm/W) Wipro LL20-281-XXX-65AL2 or Equivelent approved make" ;

142

-

-

... More
od293213/2021_2022 : Supply of 40W High efficient LED batten surface/wall mounted Specially designed extruded Aluminium housing with PC diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI >80, Temperature range-0 to 50DegC, Driver efficiency>90%, Power factor>0.95, CCT - 6500K, THD<10%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. ;Luminaire lumen ≥ 4000 lumens (100 lm/W) Wipro LL20-541-XXX-65AL1 or Equivelent approved make

323

-

-

... More
od293222/2021_2022 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)

153

-

-

... More
od293242/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self ;opening louvers working on 230 V AC supply complete with all accessories as ;required. (Make: Orient Smart Air Exhaust or equivalant approved make)

14

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
od293345/2021_2022 : Supply of surface mounting, swaged decorative street light pole of 9 meter height with 1.5 meter overhang Single arm bracket (50mm OD) suitable for mounting 1no ;s street Light fixtures. The hot-dip GI pole shall be provided with foundation base plate and the bracket assembly shall be secured on to the pole top with 2 annular rings with allen grub screws. The swaged pole with bracket,built-in cylindrical GI control box of same material with service door coated with epoxy zinc phosphate primer and finished with polyurethane based paint . The control gear box is prewired with SP MCB, FP connector for easy loop-in loop-out suitable for 3phase 4 wire AC supply.The pole shall have provision for connecting the earth wire.

13

-

-

... More
od293347/2021_2022 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79& 80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)Make: Crompton LSTS-45-CDL-M / wipro LR02-501-XXX-57-G1 or equivalent approved make.

13

-

-

... More
od295672/2021_2022 : "Supply of Outdoor Lighting Panel (ODP) cubicle type, made out of Thermoplastic UV resistant enclosure, totally enclosed, IP65, free standing, floor mounting, dust and vermin proof, powder coated, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides,including all the necessary internal wiring ,suitable spreader etc. CPRI certification for similar panel(required for short circuit rating,temperature rise and IP classification) shall be submitted Panel shall be with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. "Incomer:40 A, FP, MCB + RCCB - 1 No BUSBAR 40A TPN busbars of high conductivity electrolytic quality copper alloy INSTRUMENTS 4A, C curve SP MCB . RYB indication lamp, LED type - as per SLD timer clock with 40A FP contactor having an astronomical 365 day timer clock - OUTGOINGS 6A C Curve DP MCB- 6 Nos

1

-

-

... More
Supply, Installation, Testing & Commissioning of 63A FP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

25

-

-

... More
EARTHING AND SAFETY EQUIPMENT

-

-

-

... More
od293903/2021_2022 : Supply & providing ISI plate earthing as per IS 3043 with 1200x1200x12.5mm GI / CI earth plate with 20mm dia B class GI pipe for watering, 50x6mm GI strip welded to the plate, GI funnel with weld mesh, fixing GI strip of size 50x6mm with min. length of 20cm clamped with 50x5mm GI flat using 12x10mm GI bolt & nut at top of the GI pipe as test joint, filling around the GI pipe at a radius of 15cm with a homogeneous mixture of charcoal, & river sand upto a height of 2.5 meter from the bottom, filling the rest of the portion with excavated soil including watering & ramming providing brick work (20cm) masonary at top in 1:6 cement mortar, plastering the inside & top of the manhole with 12mm thick 1:6 cement mortar and providing gully trap with 450x450x10mm CI covering at the top. ;

12

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

60

-

-

... More
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

250

-

-

... More
od294032/2021_2022 : Providing and fixing 50 mm X 6 mm G.I. strip on surface,Tray or in recess for connectionsetc. as required.

120

-

-

... More
od294033/2021_2022 : Providing and fixing 25mm X 6mm GI ;GI strip on surface ,Tray or in recess for connections etc. as required.

268

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

40

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
od294053/2021_2022 : Supply and fixing of First aid box ;

1

-

-

... More
od294864/2021_2022 : Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip ;earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer ;etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut ;bolt & spring washer spaced at 50mm)

297

-

-

... More
UPS

-

-

-

... More
od312291/2021_2022 : Supply Installation Testing & Commissioning of 100KW Modular Rack with 25KW X 1 No modules ,suitable for future expansion upto 100kW with Input Voltage 415V, output voltage 415V, Input power factor >0.99 Thdi <3%, Efficiency at Double conversion mode >96%, IP20, with 30 mins battery back up and with all necessary Battery Breaker, Rack, Interlinks, control Cables, cables between UPS & Battery .

1

-

-

... More
HVAC EQUIPMENTS

-

-

-

... More
od309790/2021_2022 : Supply, installation, testing and commissioning (SITC) of 11 TR or higher capacity air-cooled Ductable split air conditioner (IDU ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, R407c/R410a,first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 5 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,CPVC condensate drain pipe upto 5m 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell elastomeric insulation as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, with factory laminated glass cloth suitably supported on trays, clamps, vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications

2

-

-

... More
od309791/2021_2022 : Supply, installation, testing and commissioning (SITC) of 6TR or higher capacity air-cooled Ductable split air conditioner (IDU ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, R407 C/R410a,first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 5 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,CPVC condensate drain pipe upto 5m 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell elastomeric insulation as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, with factory laminated glass cloth suitably supported on trays, clamps, vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications

2

-

-

... More
od309792/2021_2022 : Supply, installation, testing and commissioning of suitable sized copper refrigerant piping(both suction and liquid piping) beyond 5 mtr including 19mm thick closed cell elastomeric insulation with factory laminated 7mils glass cloth as per specification for 11 TR machine between indoor outdoor units as per site conditions complete in all respect inclusive of all taxes etc. complete as required by the standard technical specifications.

12

-

-

... More
od309793/2021_2022 : Supply, installation, testing and commissioning of suitable sized copper refrigerant piping(both suction and liquid piping) beyond 5 mtr including 19mm thick closed cell elastomeric insulation with factory laminated 7mils glass cloth as per specification for 6 TR machine between indoor outdoor units as per site conditions complete in all respect as per the technical specifications.

12

-

-

... More
od309797/2021_2022 : Supply, Installation, Testing and Commissioning of minimum 2.0TR nominal capacity invertor DX-Type 4-way Cassette units with three speed evaporator fan motor, cooling coil and insulated drain pan with factory installed drain pump enclosed in plastic casing complete with cordless remote control along with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor,R32/R410a/407c refrigerant, including fixing the outdoor unit as per manufacturers recommendation and fixing of unit on ceiling, fully copper coils with hydrophilic coating providing copper piping interconnection with 19mm thick round closed cell elastomeric nitrile rubber insulation Class ;O ; insulation applied by adhesive confirming to standard specification ,finished with factory laminated 7 mils woven fibre glass cloth covering and one coat of fungicidal protective coating, between Indoor and outdoor unit as per site conditions, necessary power and control cabling (indoor to outdoor), outdoor vibration isolators, suitable size CPVC drain pipe with 9mm thick round nitrile rubber insulation finished with factory laminated 7 mils woven fibre glass cloth covering and one coat two coats of fungicidal protective coating, including chasing, drilling, concealing and making good the same on walls etc. vibration isolators, charging of refrigerant gas, MS condenser stand etc. complete as required suitable for single phase 230 V supply and with suitable stabilizer etc. complete in all respects as per the technical specification .

9

-

-

... More
od309799/2021_2022 : Supply, Installation, Testing and Commissioning of minimum 1.5TR nominal capacity invertor DX-Type 4-way Cassette units with three speed evaporator fan motor, cooling coil and insulated drain pan with factory installed drain pump enclosed in plastic casing complete with cordless remote control along with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor,R32/R410a/407c refrigerant, including fixing the outdoor unit as per manufacturers recommendation and fixing of unit on ceiling, fully copper coils with hydrophilic coating providing copper piping interconnection with 19mm thick round closed cell elastomeric nitrile rubber insulation Class ;O ; insulation applied by adhesive confirming to standard specification ,finished with factory laminated 7 mils woven fibre glass cloth covering and one coat of fungicidal protective coating, between Indoor and outdoor unit as per site conditions, necessary power and control cabling (indoor to outdoor), outdoor vibration isolators, suitable size CPVC drain pipe with 9mm thick round nitrile rubber insulation finished with factory laminated 7 mils woven fibre glass cloth covering and one coat two coats of fungicidal protective coating, including chasing, drilling, concealing and making good the same on walls etc. vibration isolators, charging of refrigerant gas, MS condenser stand etc. complete as required suitable for single phase 230 V supply and with suitable stabilizer etc. complete in all respects as per the technical specification .

2

-

-

... More
od309827/2021_2022 : Supply, Installation testing and commissioning of suitable sized (Minimum 3/8"/5/8")refrigerant piping (beyond 5 m) including 19mm thick closed cell elastomeric insulation finished with factory laminated glass cloth and one coat of fungicidal protective coating as per specification interconnecting indoor outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports as per relevant standards for 2 TR Cassette type air conditioning complete in all respects as per technical specifications. Note: Both suction and liquid piping shall be considered measured as a single item.

42

-

-

... More
od309802/2021_2022 : Supply, Installation testing and commissioning of suitable sized(Minimum 3/8"/3/4") refrigerant piping (beyond 5 m) including 19mm thick closed cell elastomeric insulation finished with factory laminated glass cloth and one coat of fungicidal protective coating as per specification interconnecting indoor outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports as per relevant standards for 2 TR Cassette type air conditioning complete in all respects as per technical specifications. Note: Both suction and liquid piping shall be considered measured as a single item.

12

-

-

... More
od309805/2021_2022 : Supply, Installation testing and commissioning of suitable sized (Minimum 3/8"/5/8")refrigerant piping (beyond 5 m) including 19mm thick closed cell elastomeric insulation finished with factory laminated glass cloth and one coat of fungicidal protective coating as per specification interconnecting indoor outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports as per relevant standards for 1.5 TR Cassette type air conditioning complete in all respects as per technical specifications. Note: Both suction and liquid piping shall be considered measured as a single item.

12

-

-

... More
od309807/2021_2022 : Supply, installation testing and commissioning of 1.5 TR minimum capacity invertor Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 3 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitably sized copper refrigerant piping(upto 5 m) as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth and one coat of fungicidal protective coating as per specification interconnecting indoor outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports, necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe (upto 5 m) 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, , first charge refrigerant gas R32/R410A/R407C, cordless remote etc. complete in all respects as per the technical specifications.

2

-

-

... More
od309810/2021_2022 : Supply, Installation testing and commissioning of suitable sized refrigerant piping(beyond 5 m) including 19mm thick closed cell elastomeric insulation finished with factory laminated glass cloth and one coat of fungicidal protective coating as per specification interconnecting indoor outdoor units with required pipe fittings and accessories like Bends, Tees, reducers, supports as per relevant standards for 1.5 TR Cassette type air conditioning complete in all respects as per technical specifications. Note: Both suction and liquid piping shall be considered measured as a single item.

12

-

-

... More
od309812/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel other accessories etc. complete in all respects as per the technical specifications: 600 CFM -15 mm of WG ESP

2

-

-

... More
od309813/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel other accessories , Vibaration isolators , structural supports etc rate includes necessary wall opening and replastering of cut wall with good finish .complete in all respects as per the technical specifications: 700 CFM - 15 mm of WG ESP

1

-

-

... More
od309815/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel other accessories , Vibaration isolators , structural supports etc rate includes necessary wall opening and replastering of cut wall with good finish .complete in all respects as per the technical specifications: 1250 CFM - 20 mm of WG ESP

1

-

-

... More
od309816/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel other accessories etc. complete in all respects as per the technical specifications 1800 CFM -20 mm of WG

1

-

-

... More
od309817/2021_2022 : Supply, installation, testing and commissioning of CPVC drain pipe (beyond 5 m )of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with insulated with 9 mm thick closed cell elastomeric class 0 insulation with7 mils factory laminated glass cloth as per specification and along with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported on clamps etc. complete in all respects as per the technical specifications.

100

-

-

... More
AIR DISTRIBUTION SYSTEM

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

345

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

30

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

25

-

-

... More
od309794/2021_2022 : Supplying and fixing of 19 mm thick 55kg/m3 density, regular closed cell class 0 nitrile rubber insulation finished with 7 mils factory laminated glass cloth and with one coat of ant fungicidal coating ,anti-microbial protection. Butt all joints tightly and seal all breaks and joints by adhering glass cloth tape,(on duct ) etc. complete in all respects as required by the technical specifications

304

-

-

... More
od309796/2021_2022 : Supply , Installation testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1,having density 140-180 kg/m3 insulation using manufacturers recommended adhesive etc. complete in all respects as per technical specifications

99

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

2

-

-

... More
od309798/2021_2022 : DSR 16.16 Supplying fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

6

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

1

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

2

-

-

... More
od309803/2021_2022 : Supply, Installation , testing and commissioning of Aluminium Extruded Fresh air louvers with fresh air damper, bird screen etc. complete in all respects as per the technical specifications.

1

-

-

... More
od309804/2021_2022 : Supply, Installation, testing and commissioning of Aluminium Exhaust Air louvers , dampers, fixing supports complete in all respects as per the technical specifications

1

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

4

-

-

... More
od309808/2021_2022 : Supply, Installation ,testing commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks , complete in all respects as per the technical specifications.

3

-

-

... More
od309809/2021_2022 : Supply, Installation ,testing and commissioning of Under-deck insulation of exposed roof using Class "O" Nitrile rubber insulation of 19mm thickness, anti microbial insulation and stuck to the roof using suitable adhesives, tapes etc. as complete in all respects per the technical specification manufacturer ;s recommendation.

149

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od309726/2021_2022 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 450lpm, 40 m head C.I body, bronze impeller, SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.M.S. fabricated common base plate, foundation bolts, anti vibration pads etc. including all necessary accessories and cabling required for successful automatic operation of pump as per technical specifications.

1

-

-

... More
od309728/2021_2022 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

1

-

-

... More
od309730/2021_2022 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure, phosphor bronze bellows as sensing element, SPDT contact system with fittings, ball valve of suitable of suitable size etc. complete as required as per technical specification.

1

-

-

... More
od309736/2021_2022 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS (Heavy C ; Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

204

-

-

... More
od309737/2021_2022 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS (Heavy C ; Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

17

-

-

... More
od309738/2021_2022 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS (Heavy C ; Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

47

-

-

... More
od309739/2021_2022 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS (Heavy C ; Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

4

-

-

... More
od309740/2021_2022 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS (Heavy C ; Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

18

-

-

... More
od309741/2021_2022 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS (Heavy C ; Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

6

-

-

... More
od309742/2021_2022 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS (Heavy C ; Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

129

-

-

... More
od309743/2021_2022 : Supply, laying, testing and commissioning of ;C ; class heavy duty MS pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, GI nuts bolts, gaskets etc. in ground at a depth of 1m including excavation providing cement concrete blocks as supports, applying bituminous primer, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification.- 100 mm dia

7

-

-

... More
od309744/2021_2022 : Supply, laying, testing and commissioning of ;C ; class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc. complete as required as per the technical specification.

24

-

-

... More
od309745/2021_2022 : Supply, installation, testing and commissioning of dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required.

1

-

-

... More
od309746/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

9

-

-

... More
od309747/2021_2022 : Supply, installation, testing and commissioning of 100 mm dia Y strainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od309748/2021_2022 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification

10

-

-

... More
od309749/2021_2022 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal) dia gun metal globe valve nozzle (c) Drum and brackets for fixing the equipment on wall (d) Connections from riser with 25 mm dia stop valve with pipe and socket

8

-

-

... More
od309750/2021_2022 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI/MS/SS wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

20

-

-

... More
od309751/2021_2022 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification

10

-

-

... More
od309752/2021_2022 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

10

-

-

... More
od309753/2021_2022 : Supply, installation, testing and commissioning of 2-WAY FIRE BRIGADE inlet connection made of CI Body, 100mm dia. flanged inlet with 2 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

1

-

-

... More
od309754/2021_2022 : Providing, fixing, testing commissioning of UL listed, Standard response, standard coverage upright type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. with all accessories complete as required as per the technical specification.

41

-

-

... More
od309755/2021_2022 : Supply, installation, testing and commissioning of Gun metal Air release valve, 25mm male threaded inlet, complete with all accessories as required as per the technical specification.

4

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od309718/2021_2022 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

18

-

-

... More
od309720/2021_2022 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

2

-

-

... More
od309725/2021_2022 : Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

1

-

-

... More
SIGNAGES

-

-

-

... More
od309719/2021_2022 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws double tape or hanged from the false ceiling with the help of chain screws etc. complete as required as per the technical specification.

11

-

-

... More
od309724/2021_2022 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws double tape or hanged from the false ceiling with the help of chain screws etc. complete as required as per the technical specification.

6

-

-

... More
od309727/2021_2022 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws double tape or hanged from the false ceiling with the help of chain screws etc. complete as required as per the technical specification.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.