KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date16 Sep 2023
Closing Date10 Oct 2023
Tender Amount₹ 11,41,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

2305.93

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

67.65

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

374.5

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

47.64

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

6

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

7

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

2

-

-

... More
2.33.4 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth

2

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1.13

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1.75

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

296.42

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.35

-

-

... More
4.2.3 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

4.12

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

42.91

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

122.79

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

35613.7

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

5880.51

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

547.39

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

7.61

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

753.18

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

113.97

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

3173.28

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

14.45

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

3716.74

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

1.92

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

2129.41

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

178.42

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

974.72

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

522.75

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

2761.41

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

0.41

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

0.24

-

-

... More
5.13 : Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span up to floor five level, including the cost of required centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

0.39

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

44859.04

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1608.76

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

137357.85

-

-

... More
5.28 : Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints.

58.5

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

619.5

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

33.9

-

-

... More
6.23 : Honey-comb brick work 10/11.4 cm thick with common burnt clay bricks of class designation 7.5 in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand).

12.35

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor Vlevel with RCC band at sill level and lintel level with approved block laying polymermodified adhesive mortar all complete as per direction of Engineer-in-Charge. (Thepayment of RCC band and reinforcement shall be made for seperately).

675.6

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

58.85

-

-

... More
8.2.1.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

61.54

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

434.1

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

34

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.

875.48

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

4.46

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately)Second class teak wood35 mm thick shutters

157.44

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

92.16

-

-

... More
9.7.7.2 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.5mm thick glass pane

3.84

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

2.43

-

-

... More
9.14 : Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)

181.67

-

-

... More
9.20.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

55.58

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

23.27

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

8418.19

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

580

-

-

... More
9.70.4 : Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:50x37x1.50 mm

4

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

35

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

108

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

227

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

70

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

84

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

108

-

-

... More
9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.

71

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

203

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

58.8

-

-

... More
9.125 : Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.

2.1

-

-

... More
9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710

59.61

-

-

... More
9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

106.78

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

50.8

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

11.68

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

5.65

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

14.13

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

5

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

2.5

-

-

... More
10.19 : Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

196.46

-

-

... More
10.27.2 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm

130

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

2258.52

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

53.65

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

38.13

-

-

... More
11.20.4 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigment

7.65

-

-

... More
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick

73.62

-

-

... More
11.27 : Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

5.06

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

26.65

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

3.29

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

25.38

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

256.68

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

344.66

-

-

... More
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)

25.7

-

-

... More
12.53 : Providing and Fixing 15 mm densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone /cosmos /Hexa or equivalent of size 595x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main 'T' of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid, including cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main 'T' runners to be suspended from ceiling using G.I slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm, spaced at 1200mm centre to centre along main 'T' bottom exposed with 24 mm of all T- sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), light reflection 85% non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC.

189.2

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

12649.67

-

-

... More
13.4.2 : 12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand)

103.91

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

3637.33

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

16870.96

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

1359.23

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

93.08

-

-

... More
13.32.1 : Pointing on tile brick work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush /Ruled / Struck or weathered pointing

24.7

-

-

... More
13.41.1 : Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work ( Two or more coats) over and including priming coat with water thinnable cement primer

71.02

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

10934.15

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

585.67

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

33.38

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

375.02

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

4483.63

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

31.08

-

-

... More
13.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)

479.06

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

10277.47

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

510.13

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

122.13

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

448

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

15.75

-

-

... More
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade

151.2

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

112

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

112

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

2936.69

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

2358.79

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

44.22

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

15

-

-

... More
21.7.2 : Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Powder coated aluminium sheet 2.5 mm thick ( minimum thickness of powder coating 50 micron)

320.79

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

20

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

169.6

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

50.52

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

183.42

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

1081.83

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.

328.39

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

92.15

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

77

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

1

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

1

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).

108

-

-

... More
26.22.1 : Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles.

562.82

-

-

... More
30.2.57.1 : Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100)

100

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

300.65

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

97.8

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

79.56

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

15.64

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

2.66

-

-

... More
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

43.04

-

-

... More
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete

1.83

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

4.97

-

-

... More
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop

2

-

-

... More
od39858/2022_2023 : Providing and laying factory made chamfered edge Cement Concrete Perculation paver blocks (Glass paver) in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking Perculation paver blocks (Glass paver) into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete Perculation paver blocks (Glass paver) of M-35 grade with approved colour, design& pattern.

28.2

-

-

... More
od51443/2020_2021 : Providing and laying Double charged Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800 x 800 mm(The base price considered for the Double charged vitrified tile is 592/sqm)

219.22

-

-

... More
od51444/2020_2021 : Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) , including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x 800 mm (The base price considered for the Double charged vitrified tile is 592/Sqm)

2766.37

-

-

... More
od51470/2020_2021 : Providing and laying Double charged Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800 x 800 mm(The base price considered for the Double charged vitrified tile is 592/sqm)

12.85

-

-

... More
od51471/2020_2021 : Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) , including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x 800 mm (The base price considered for the Double charged vitrified tile is 592/Sqm)

185.76

-

-

... More
od51473/2020_2021 : Providing and applying melamine matt finish on wood work after scraping and cleaning the surface applying necessary coats of putty, filler and sealer, etc. Sanding shall be done along the grains using water paper/emery paper before applying filler, sealer and melamine to get a perfectly smooth and uniform finish. Melamine and sealer shall be applied using spary gun. The rate shall include cost and conveyance of all materials, lead lift, all labour

67.36

-

-

... More
od51478/2020_2021 : Extra for providing architechtural grooves 25 mm x 6mm in plastering @125mm c/c, including cost and conveyance of all material, labour, scaffolding etc. complete as directed by the Engineer in charge.

256.02

-

-

... More
od51499/2020_2021 : Supplying And Fixing a pair of fire rated Solid SS Lever Handle and Mortise Lock case with Cylinder of approved size and quality for fire rated steel doors etc complete all works including all required fixtures as directed by Engineer in Charge.

22

-

-

... More
od51505/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work upto plinth level

13.14

-

-

... More
od51509/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
od51512/2020_2021 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note :- Minimum Cement content considered in M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).

17.3

-

-

... More
od51513/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

2

-

-

... More
od68994/2022_2023 : Providing and stacking of Tectona grandis (Teak) of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od68995/2022_2023 : Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od68996/2022_2023 : Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.

10

-

-

... More
od68997/2022_2023 : Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge.

10

-

-

... More
od68998/2022_2023 : Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.

10

-

-

... More
od68999/2022_2023 : Providing and stacking of Peltophorum species of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od69000/2022_2023 : Providing and stacking of Mimusops elengi (Maulsri) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od69001/2022_2023 : Providing and stacking of Michelia champa (Golden Champa) of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od69002/2022_2023 : Providing and stacking of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
od103630/2020_2021 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

1359.1

-

-

... More
od103631/2020_2021 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

178.82

-

-

... More
od103632/2020_2021 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

277.39

-

-

... More
od103640/2020_2021 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

123.91

-

-

... More
od106611/2020_2021 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

2150.9

-

-

... More
od158528/2020_2021 : Providing ,hoisting and fixing at all level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand conforming to IS383), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete as per direction of Engineer-in-charge but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.Minimum cement content considered in this item is @ 330 kg/cum

0.46

-

-

... More
od158559/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.(Note :- Minimum Cement content considered in this item is @ 320 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).All work up to plinth level

1.03

-

-

... More
od158562/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.(Note :- Minimum Cement content considered in this item is @ 320 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).All works above plinth level upto floor V level

0.44

-

-

... More
od158788/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

162.69

-

-

... More
od158810/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

11.86

-

-

... More
od158811/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

34.4

-

-

... More
od158835/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

221.09

-

-

... More
od158866/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

42

-

-

... More
od221482/2019_2020 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
od221483/2019_2020 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

220.5

-

-

... More
od221485/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work upto plinth level

250.49

-

-

... More
od221486/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work above plinth level upto floor V level

951.57

-

-

... More
od221487/2019_2020 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note :- Minimum Cement content considered in M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).

28.56

-

-

... More
od221488/2019_2020 : Providing and fixing zinc alloyed (white powder coated) touch lock for Aluminium/uPVC sliding window with necessary screws etc. complete.

432

-

-

... More
od221490/2019_2020 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for inside panel excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: 8 mm thick glass pane

10.5

-

-

... More
od221491/2019_2020 : Providing and fixing hardwares for Handicaped door(Excluding door frame and panel).The shutter to be provided with cylindrical knob lock with rose diameter 75 mm and SS matt finished kick plate of dimension 300 MM X 1050 MM X 1MM including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing etc. complete as directed by the Engineer-in-Charge at all levels:

3

-

-

... More
od221493/2019_2020 : Providing and fixing PVC tile edging to match the wall tiles and finishing as directed by the Engineer-in-Charge at all levels.

147

-

-

... More
od221495/2019_2020 : Providing and applying melamine matt finish on wood work after scraping and cleaning the surface applying necessary coats of putty, filler and sealer, etc. Sanding shall be done along the grains using water paper/emery paper before applying filler, sealer and melamine to get a perfectly smooth and uniform finish. Melamine and sealer shall be applied using spary gun. The rate shall include cost and conveyance of all materials, lead lift, all labour

527.9

-

-

... More
od221496/2019_2020 : Providing and fixing S.S fan clamp of 16mm dia in RCC slabs, beams including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge at all levels.

60

-

-

... More
od221497/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In gratings, frames, guard bar, ladders, railings, brackets, gates similar works.

8511.6

-

-

... More
od221498/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, scaffolding, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In stringers, treads, landings etc of staircases including use of chequered plate wherever required, all complete

118.18

-

-

... More
od221939/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work upto plinth level

65.01

-

-

... More
od221940/2019_2020 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note :- Minimum Cement content considered in M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).

65.01

-

-

... More
od221941/2019_2020 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

4

-

-

... More
od221943/2019_2020 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge 110mm OD(6 kg/cm2)

30

-

-

... More
od221944/2019_2020 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

2

-

-

... More
od222307/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work upto plinth level

17.3

-

-

... More
od222340/2019_2020 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

2

-

-

... More
od222410/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work upto plinth level

46.39

-

-

... More
od222411/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work above plinth level upto floor V level

3.52

-

-

... More
od222412/2019_2020 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note :- Minimum Cement content considered in M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)

46.39

-

-

... More
od222413/2019_2020 : Providing and fixing zinc alloyed (white powder coated) touch lock for Aluminium/uPVC sliding window with necessary screws etc. complete.

6

-

-

... More
od222666/2019_2020 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, bending, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.

540

-

-

... More
od222669/2019_2020 : Structural steel work welded in single sections,trussess and framed work including cutting, hoisting, fixing in position and applying two coats of Synthetic enamel paint over two coats of anticorrossive Yellow zinc chromate primer including cost and conveyance of all materials,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.

150

-

-

... More
od222788/2019_2020 : Random rubble masonry with departmentally supplied hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)

45.99

-

-

... More
od222789/2019_2020 : RR with Departmental Stone: Random rubble masonry with departmental rubble in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) Cement mortar 1:6 (1 cement : 6 coarse sand)

43.8

-

-

... More
od222798/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work upto plinth level

46.22

-

-

... More
od222799/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting). All work above plinth level upto floor V level

40.25

-

-

... More
od222800/2019_2020 : Providing and fixing steel (white power coated) crescent lock for uPVC /aluminum sliding window/ door with necessary screws etc. complete.

48

-

-

... More
od222802/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In gratings, frames, guard bar, ladders, railings, brackets, gates similar works.

946

-

-

... More
od222803/2019_2020 : Structural steel work welded in built up sections,trussess and framed work including cutting, hoisting, fixing in position and applying two coats of Synthetic enamel paint over two coats of anticorrossive Yellow zinc chromate primer including cost and conveyance of all materials,labour charges, lead,lift etc complete as directed by Engineer in Charge at all levels.

8317.47

-

-

... More
od222804/2019_2020 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, bending, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.

166.32

-

-

... More
od222805/2019_2020 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

36.96

-

-

... More
od222806/2019_2020 : Providing edge moulding to kota stone counters, vanities ,steps etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge. stone work

47.5

-

-

... More
od222807/2019_2020 : Providing and fixing 25cm wide, 45 cm depth(or nearest size) Aluminum gutter of 1.2mm thick with MS brackets , bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.

51.4

-

-

... More
od222810/2019_2020 : Structural steel work welded in built up sections,trussess and framed work including cutting, hoisting, fixing in position and applying two coats of Synthetic enamel paint over two coats of anticorrossive Yellow zinc chromate primer including cost and conveyance of all materials,labour charges, lead,lift etc complete as directed by Engineer in Charge at all levels.

1367.36

-

-

... More
od222811/2019_2020 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, bending, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.

24529.95

-

-

... More
od222812/2019_2020 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer. M.S. tube

1206

-

-

... More
od222830/2019_2020 : Extra for providing architechtural grooves 25 mm x 6mm in plastering @125mm c/c, including cost and conveyance of all material, labour, scaffolding etc. complete as directed by the Engineer in charge.

75.74

-

-

... More
od222876/2019_2020 : Design, supply and fixing of PUF Panel in 50mm thick, made out of 0.50mm TCT 300Mpa 150GSM (AZ 150) colour coated Profiled galvalume sheets of approved colour (34.5mm crest height in 333.3mm pitch) on the top and 0.50mm TCT 300Mpa 150GSM colour coated galvalume slightly ribbed sheet at the bottom with Polyurethane Foam insulation as infill. The colour coating on sheet shall have a total coating thickness of 35 micron comprising of 20 micron Silicon Modified Polyester Paint system of approved colour on the top and 5 micron back up epoxy coating at the bottom over 5 micron primer coating on both sides. The infill insulation material  (PUF) shall be fire retardant self extinguishing CFC/HCFC Free and Zero ODP (Ozone Depletion Potential). Polyurethane Foam shall have a density of 40 + 2Kg/M3 in 50mm thick (50 mm + 34.5mm at crest) injected in between the top & bottom sheet using a special foaming machine. The panels will be supplied in 1023mm supply width (1mtr effective width) and length can be as per the site requirement up to a maximum of 12mtr. The panel shall be manufactured from a continuous panel manufacturing line using pentane as blowing agent.  The panel shall be directly fixed to the purlins with galvanized imported self drilling and self tapping fasteners with EPDM washers. All the joints will be sealed with sealants and stitched with stitching screws wherever necessary, all complete as per technical specification and as directed by the Engineer-In-Charge.

779.88

-

-

... More
od222877/2019_2020 : Providing and fixing Gutter ( excluding gutter support) in required width (upto a maximum of 1200mm girth) with plain galvalume colour coated sheet made out of 0.5mm TCT, minimum 300 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges etc. complete at all levels as directed by Engineer-in-Charge

58.2

-

-

... More
od222878/2019_2020 : Providing and fixing ridge/ valley capping/flashing in required width (upto maximum 600 mm) with plain galvalume colour coated sheet made out of 0.50mm TCT, minimum 300 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges etc. complete at all levels as directed by Engineer-in-Charge

58.2

-

-

... More
od330788/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level

9.42

-

-

... More
od330796/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level

39.43

-

-

... More
od330873/2021_2022 : Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding window with necessary screws etc. complete.

12

-

-

... More
od331452/2021_2022 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level up to floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

2.88

-

-

... More
od331901/2021_2022 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

3.29

-

-

... More
od336936/2021_2022 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

97.26

-

-

... More
od336971/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With high performance glass panes of 6 mm thickness meeting GRIHA compliance of overall value "VLT > 50%, SHGC < 0.50

578.28

-

-

... More
od336996/2021_2022 : Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

80.92

-

-

... More
od337010/2021_2022 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

22.25

-

-

... More
SANITARY WORKS

-

-

-

... More
od222345/2019_2020 : Providing and fixing star white vitreous china under counter wash basin of approved size & make including one CP brass pillar cock 15 mm NB with aerator with max flow rate of 3.8l pm or lower as per GRIHA norms including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap, 15mm angle valve, etc. complete as directed by the Engineer-incharge at all levels.(Models Cera S2030103/ Hindware 1004900SW+ Cera F1015101/Hindware F280001CP or equivalent as per the instructions of the engineer in charge)

46

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

42

-

-

... More
od222346/2019_2020 : Providing and fixing white vitreous china flat back urinal with sensor and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Models Hindware 6002110 / Cera S4010101 or equivalent with griha water conservation mechanism etc complete as directed by the Engineer in charge at all levels

12

-

-

... More
od222347/2019_2020 : Supplying and fixing approved quality white vitreous china urinal division plate including cost and conveyance of all material, labour charge, lead, lift, etc. complete as directed by the Engineer-in-Charge. Models- Cera S4090101/ Hindware 61001 or equivalent

12

-

-

... More
od314063/2021_2022 : Providing and fixing C.P. brass long body bib cock with griha complying flow rates upto 5lpm mechansim of approved quality conforming to IS standards and weighing not less than 690 gms. Models Hindware F400002CP/ Jaquar FLR-CHR-5047NGE or equivalent 15 mm nominal bore

42

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

6

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

46

-

-

... More
od222350/2019_2020 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

62

-

-

... More
od222351/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.75mm dia

10

-

-

... More
od222352/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.110 mm dia

10

-

-

... More
od222353/2019_2020 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin , one pair mounting brackets,one number pillar cock & all other related fittings like bottle trap ,angle cock,waste coupling, etc,one number EWC & Cistern complete with fittings & seat cover, one no. hinged rail 76cm & 4nos. of grab rails 60cm etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge. (Model no: Hindware (70002+ Flora F280001)/Cera (S1012135+B1520118+S2040101+S2090102+F9030451+B2210106+B2210108+ F1015101CH ) or equivalent)

3

-

-

... More
od313945/2021_2022 : Providing and fixing white vitreous china extended wall mounting water closet of approved shape and size including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 2 litre/4 litres , including seat cover,angle valve and cistern fittings, nuts bolts and gasket etc complete as directed by the engineer in charge at all levels. Models Cera S1031111+B1020105+B1520102/ Hindware 20096 (P-15)+Cist.: 21056 or equivalent with griha water conservation mechanism etc complete as directed by the Engineer in charge at all levels.

39

-

-

... More
od222401/2019_2020 : Providing and fixing CP Brass robe hook as per the instructions of the Engineer in charge. Models Cera F5003108/ Hindware F880004CP or equivalent

42

-

-

... More
WATER SUPPLY

-

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

12

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

18

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

84

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

6

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

30

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

5

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

10

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

10

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

20

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

20

-

-

... More
18.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

10

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal bore Horizontal

2

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal bore Horizontal

4

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

120

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

30

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
od222537/2019_2020 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame (medium duty) : With bricks.Class designation 75

10

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

1

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

5

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

72

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

328

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

140

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

170

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

142

-

-

... More
od222356/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 75 mm dia pipes

96

-

-

... More
od222549/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 100 mm dia pipes

6

-

-

... More
od222357/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 62.5 mm dia pipes

84

-

-

... More
od222358/2019_2020 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200mm dia 6 Kgf/cm2

60

-

-

... More
od222359/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 40 mm

2

-

-

... More
od222360/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mm

4

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

8

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

4

-

-

... More
od222370/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer

2

-

-

... More
od222371/2019_2020 : Providing and fixing CI Y type strainer 65mm dia rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge

2

-

-

... More
od222372/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 40mm 'Y' type strainer

2

-

-

... More
od222373/2019_2020 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

4

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

72

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

10

-

-

... More
18.31.1.1 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass I

1

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

18

-

-

... More
od222557/2019_2020 : Providing and fixing enclosed type water meter (bulk type) 65mm dia conforming to IS :2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labouRretc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od222558/2019_2020 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm dia

6

-

-

... More
od222566/2019_2020 : >Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels >Head 24m, Capacity-13 m3/hr

4

-

-

... More
od222559/2019_2020 : Supplying and fixing gun metal Non return valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer- in-Charge at all levels 32 mm

2

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

18

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

240

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

293

-

-

... More
od222377/2019_2020 : Supplying, fixing and commissioning of centrifugal pump of CI construction, bronze impeller complete with motor,working with 415 V, 3 pH, 50 Hz including base plate foundation bolts, nuts, pressure gauge, priming arrangements and all accessories. 'Capacity : 5 cum/hr, Head : 35 metre

4

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

220

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

435

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

60

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

30

-

-

... More
18.9.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes

6

-

-

... More
18.9.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes

18

-

-

... More
od222718/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm

5

-

-

... More
od222719/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

5

-

-

... More
od222720/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 200mm

2

-

-

... More
od222721/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 80mm

5

-

-

... More
od222722/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mm

5

-

-

... More
od222723/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 200mm

2

-

-

... More
od222724/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm

5

-

-

... More
od222725/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mm

5

-

-

... More
METERING KIOSK

-

-

-

... More
od313575/2021_2022 : Supply, installation, testing and commissioning of OUTDOOR metering panel,including supplying and fixing CT operated bidirectional TOD meter and consisting of 3 nos. of 160 A cutout with HRC fuse, neutral link, 160 A FP MCCB , CBCT protection for earth fault in separate chamber,inter connections etc. as required, and necessary supports to be fabricated out of 14 SWG CRCA sheet with lockable door with sealing facility having glass window for energy meter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required .The panel shall with all accessories as per drawing & specification

1

-

-

... More
LT PANELS

-

-

-

... More
od319847/2021_2022 : Supply, Installation, Testing & Commissioning of Main Switch Board (MSB) , cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 42 form b, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised , suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size wires/cable, interconnection, duly powder coated with seven tank process etc., including following components as per drawing and technical specifications. The panel shall be with Top entry to receive incoming & outgoing cable Incomer 1 160A, FP MCCB 25kA Thermal-magnetic based - 1 No >Incomer 2 125A, FP MCCB 25kA Thermal-magnetic based- 1 No Instruments(incomer) 4A MCB - 6 nos RYB indication lamp, LED type - 2 set ONOFF- TRIP indicator -2 set (0-500)V voltmeter, Acc. class 1 with 90 deg defl. scale - 2Nos. (0- 160)A ammeter Acc. class 1 with 90 deg defl. scale - 3Nos. (0-125)A ammeter Acc. class 1 with 90 deg defl. scale - 3Nos 160/5A 5VA class 1 resin cast CT -1set 125/5A 5VA class 1 resin cast - 1set Digital multifunction meter ( V, A, F,pf,kW, kWh) - 2No. voltmeter selector switch - 2No. Surge protection device type 1-1 SET 160A FP ATS with AMF facility -1No Busbar 160A ,25kA TPN Al busbar Outgoings 63 A,TPN, 25kA, MCCB with adjustable thermal magnetic release with OL & SC protection - 5Nos 125 A,TPN, 25kA, MCCB with adjustable thermal magnetic release with OL & SC protection - 1Nos 63A TPN MCCB Isolator- 1Nos. 40 A,TPN, 25kA, MCCB with adjustable thermal magnetic release with OL & SC protection - 2Nos

1

-

-

... More
od319850/2021_2022 : Supply, Installation, Testing and Commissioning of 82.5kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 82.5 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conformingto BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be inculsive of all the civil work like RCC foundation. The work should be as per Electrical Inspectorate/ Central Pollution control board standardsapplicable at the time of delivery. The rate shall be inclusive of civil foundation works

1

-

-

... More
od319851/2021_2022 : Supply , Installation, Testing and Commissioning of 15 kVA, three phase input, three Phase output, true on-line UPS system with 30 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit and one set of battery bank . Refer technical specification and drawing for details. Fully digital controlled based on DSP, Power factor corrected from end > 0.9, Pure sine wave output, Full time output voltage & frequency regulation, Auto regulation of battery end voltage, Intelligent interface with LED/LCD display, Static bypass switch / manual by pass switch, Auto temperature compensation

1

-

-

... More
CABLES AND CABLING

-

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

10

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

12

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

145

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

57

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

10

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

10

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

19

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

24

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

435

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

842

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

40

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

40

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

60

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

100

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

5

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

10

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

5

-

-

... More
9.1.9 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 25 sq. mm (25mm)

4

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
od320130/2021_2022 : Supply of following 4C 35 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

234

-

-

... More
od320131/2021_2022 : Supply of 3C 4 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

216

-

-

... More
od320133/2021_2022 : Supply of following 4C 2.5Sq.mm Cu size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

216

-

-

... More
od320136/2021_2022 : Supplying and making end termination with brass compression gland and Cu lugs for following 4Cx2.5 sqmm size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required

24

-

-

... More
od320139/2021_2022 : Supply of 2C 4 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

66

-

-

... More
od320140/2021_2022 : Supply of 4C 16 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

132

-

-

... More
od321715/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for following 4C 4 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

50

-

-

... More
od321845/2021_2022 : Supply of following 4C 4 Sq.mm Cu size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

552

-

-

... More
od321846/2021_2022 : Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 3C 4Sq mm Cu

24

-

-

... More
od321850/2021_2022 : Supplying and making end termination with brass compression gland and CU lugs for following size of PVC insulated and PVC sheathed / XLPE CU conductor cable of 1.1 KV grade as required. 2 X 4 sq. mm

6

-

-

... More
od321853/2021_2022 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

200

-

-

... More
od321854/2021_2022 : Supply of 3.5C 185 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Al conductor cable conforming to IS 7098 (Part 1) amended upto date.

72

-

-

... More
od321860/2021_2022 : Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke & Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

0.5

-

-

... More
od321861/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 25 sqmm Al

36

-

-

... More
od321862/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 95 Sq.mm Al

120

-

-

... More
od321871/2021_2022 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx120sq.mm Al Cable

24

-

-

... More
WIRING AND ACCESORIES

-

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

3515

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

2309

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

953

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

434

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

6

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

30

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

60

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

27

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

3

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

13

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

4

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

67

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

4

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

50

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

152

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

20

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

150

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

100

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

44

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

13

-

-

... More
od322004/2021_2022 : Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.

68

-

-

... More
od322005/2021_2022 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

39

-

-

... More
od322006/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

20

-

-

... More
LIGHT FIXTURES AND FAN

-

-

-

... More
od313805/2021_2022 : Supply of IP66 streetlight luminaire made of die cast aluminium along with driver,system wattage of 30+/- 2 Watts,lumen output of luminaire greater than 3000 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 100lumen/watt ,wth suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Wipro LR02- 331-XXX-57-XX or other approved equivalent makes)

10

-

-

... More
od313833/2021_2022 : Supply of outdoor BULKHEAD luminaire made of polycarbonate housing along with driver,system wattage of 10+/-2 Watts,lumen output of luminaire greater than 700 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 70 lumen/watt ,with suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Crompton -LBHP -10-CDL or other approved equivalent makes)

18

-

-

... More
od313834/2021_2022 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser, along with driver,system wattage of 20+/-2 Watts,lumen output of luminaire greater than 2000, power factor >0.9,rated life of L70 @ 35,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete

82

-

-

... More
od313836/2021_2022 : Supply of indoor decorative surface mounted LED Batten with PolycarbonateDiffuser ,along with driver,system wattage of maximum 10Watts,lumen output ofluminaire greater than 1000, power factor > 0.95,rated life of L70 @ 25,000 hours,system efficacy greater than 100lumen/watt and including all the necessaryaccessories as required complete

54

-

-

... More
od313843/2021_2022 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)

130

-

-

... More
od313844/2021_2022 : Supply of indoor industrial surface mounted LED tube with Batten along withdriver , surge protector, maximum system wattage of 40+/-4 Watts,lumen outputof luminaire greater than 4000 lumen, power factor > 0.9,rated life of L70 @50,000 hours, system efficacy greater than 100lumen/watt and including allnecessary accessories as required complete Cat No: WIPRO OPTIMA II24

221

-

-

... More
od313846/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Crompton Exhaust or equivalant approved make)

34

-

-

... More
od313847/2021_2022 : Installation, testing and commissioning of High bay/LED/ T5 FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.

10

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

375

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

630

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

29

-

-

... More
od313909/2021_2022 : Supply of 450 mm sweep,900 rpm heavy duty exhaust fan in metal body with louvers working on 230 V AC supply complete with all accessories as required. (Almonard or equivalant approved make)

3

-

-

... More
od313910/2021_2022 : Installation, testing and commissioning of LED PANEL fittings with chain and copper wiring with all accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor cable as required.

81

-

-

... More
od313921/2021_2022 : Supply of 2x2 LED recess mounted fixture with housing made of pressure die cast aluminum body and ahigh efficiency diffuser along with driver, system wattage 33+/-3 Watts, cool white fixture (CCT-5700)lumen output of luminaire greater than 3500 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours,system efficacy greater than 100 lumen/watt ,with suitable driver and including all necessary accessoriesas required complete Make : Crompton – LCTLRNE-36-FO-CDL

81

-

-

... More
DB AND MCB

-

-

-

... More
od313937/2021_2022 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 2 pole 25 amps. (415 Volts),100mA sensitivity.

4

-

-

... More
od313938/2021_2022 : Supply installation, testing and commissioning of DOL starter upto 5HP,3ph motor including auxilliary contactors, 2kVAR capacitor and all necessary accessories as required complete with single phase preventor, function indiaction etc.

12

-

-

... More
od319617/2021_2022 : Supply and fixing of following 4 pole 40amps. (415 Volts),100mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

2

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
od313944/2021_2022 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all thenecessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

13

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

4

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

200

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

60

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

40

-

-

... More
od313953/2021_2022 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40 A to 63A TP MCB, C-CURVE

10

-

-

... More
od313970/2021_2022 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp,25KA, FP MCCB

1

-

-

... More
od313973/2021_2022 : Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

2

-

-

... More
od313977/2021_2022 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6A to 32A ,SP D CURVE

60

-

-

... More
od313998/2021_2022 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.> Four Pole

6

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

9

-

-

... More
od314042/2021_2022 : Supply, Installation, Testing & Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

2

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od319698/2021_2022 : Supply and fixing of following 4 pole 25amps. (415 Volts),100mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

5

-

-

... More
90.14.28.7 : S & F Motor starters of the following ratingsFully automatic star delta starter for 25HP motor

1

-

-

... More
od321900/2021_2022 : Supplying and fixing 6 amps to 32 amps Triple pole rating, 415 volts, "D" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.

10

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

4

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
od321909/2021_2022 : Supplying and fixing 6 A to 32 A rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole

4

-

-

... More
od321910/2021_2022 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 25A, 2P MCB

1

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
2.2.2 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required125 Amp,16 KA,TPMCCB

1

-

-

... More
EARTHING AND ACCESORIES

-

-

-

... More
od314050/2021_2022 : Providing and fixing Cu strip on surface or in recess for connections etc. as required.-25x3mm Cu

40

-

-

... More
od314051/2021_2022 : Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

60

-

-

... More
od314059/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 3.15mm Cu (10 SWG)

388

-

-

... More
od314060/2021_2022 : Supply and laying 10SWG cu wire at 0.50 meter below ground level for conductor earth electrode , including connection/termination

60

-

-

... More
od314065/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 25x6mm GI

80

-

-

... More
od315818/2021_2022 : Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

80

-

-

... More
od321311/2021_2022 : Earthing with C.I. earth pipe 3 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate

10

-

-

... More
od324829/2021_2022 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

1

-

-

... More
od324833/2021_2022 : Supply and fixing anodised aluminum glass framed shock treatment chart

1

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
od324883/2021_2022 : Supply and fixing of First aid box

1

-

-

... More
SOLAR PANEL AND ACCESSORIES

-

-

-

... More
od321580/2021_2022 : "Supply, Installation, Testing and Commissioning of Grid Tied solar string inverter of 6kVA rating , IP 66 rated, outdoor, three Phase output, true sinewave inverter system, with Maximum Power Point Tracker charge controller. Inverter should have MPPT with 1 string per MPPT. Minimum protection required shall be over voltage/surge, over load, short circuit and anti- islanding protection. Earthing shall be provided as per IEC standards. IGBT based true sine wave output. Unity Power factor(6kVA=6kW) . Accuracy of AC voltage control = +/-3%. Accuracy of AC frequency control = +/-1%. Frequency = 50Hz. Intelligent interface with LED/LCD display(Bluetooth/Wifi interface is also acceptable) . .Total Harmonic Distortion <3%”. The inverter should have all specification, protections, operational modes, etc as detailed in techinical specification. The inverter should have in-built Type Surge protection device on AC and DC side.The item includes all necessary accessories like supports, canopy, AC Isolation boxes(with energy meter), Junction boxes, Combiner boxes, DCDBs, cabling from AC Isolation boxes to inverter, connectors, etc as required complete as per technical specification.

1

-

-

... More
od321581/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for 2C 1.5sqmm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

2

-

-

... More
od321582/2021_2022 : Supply of 2C 1.5sqmm 1.1 kV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

80

-

-

... More
od321583/2021_2022 : Supplying and termination of UV Resistive MC4 Connectors suitable for terminating 4 Sq. mm copper cables(Male & Female Connectors). Y connector at Inverter end also shall be measured under this item.The item includes all necessary accessories tape etc as required complete as per techical specififcation.

32

-

-

... More
od321584/2021_2022 : Supply and laying of Single core 4 Sq. mm Unarmoured copper Solar cables from Modules to String Combiner / Monitoring Box/inverter. The item includes all necessary accessories clamp, ties etc as required complete as per techical specififcation.

80

-

-

... More
od321585/2021_2022 : Supply fabrication, erection of Mounting structures for solar panels with Hot dip galvanized GI rectangular Tubes. The Mounting structure should have 40mm GI angle section for routing 4 Sq. mm DC cables between Modules and Modules to cable trays, including necessary clamps, welding, nuts, bolts, etc. Mounting structure shall be fabricated for group of panels(4 Nos) as per technical specification. (Item shall be measured against number of panel)

15

-

-

... More
od321586/2021_2022 : Supply, installation testing and commissioning of MONO PERC module solar photovoltaic panels of total of 6kWp rating meeting IEC 61215 (revised) / IS 14286 / IEC 61646 standards & IEC 61730-1 with minimum efficiency of 19.5% with all accessories as per the tender specifiation.

1

-

-

... More
FIRE HYDRANT SYSTEM

-

-

-

... More
od222727/2019_2020 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: Monoblock Pump rated for 450lpm, 40m head C.I body, bronze impeller, SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation. M.S. fabricated common base plate and suitable cement concrete foundation, complete as required as per the technical specification.

1

-

-

... More
od222732/2019_2020 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0-14 Kg/sq.cm) range, 3/8" BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valve of suitable size etc. complete as required as per technical specification.

1

-

-

... More
od222734/2019_2020 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure, phosphor bronze bellows as sensing element, SPDT contact system with fittings, ball valve of suitable of suitable size etc. complete as required as per technical specification.

1

-

-

... More
od222738/2019_2020 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

109

-

-

... More
od222740/2019_2020 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

6

-

-

... More
od222792/2019_2020 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

132

-

-

... More
od222793/2019_2020 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

2

-

-

... More
od222794/2019_2020 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

41

-

-

... More
od222795/2019_2020 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

10

-

-

... More
od222796/2019_2020 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

41

-

-

... More
od222744/2019_2020 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 100mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc. complete as required as per the technical specification.

15

-

-

... More
od222746/2019_2020 : Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification. 80 mm dia

2

-

-

... More
od222777/2019_2020 : Supply, installation, testing and commissioning of dual plate non-return valve of PN 16 rating confirming to API 594 complete with rubber gasket, GI bolts, nuts, washers etc. as required as per technical specification. 100 mm dia

1

-

-

... More
od222779/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, SS Disc, Nitrile Rubber Seal, O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 100 mm dia

6

-

-

... More
od222780/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, SS Disc, Nitrile Rubber Seal, O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 40 mm dia

1

-

-

... More
od222752/2019_2020 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification

7

-

-

... More
od222754/2019_2020 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal) dia gun metal globe valve & nozzle (c) Drum and brackets for fixing the equipment on wall (d) Connections from riser with 25 mm dia stop valve with pipe and socket

6

-

-

... More
od222755/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI/MS/SS wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

14

-

-

... More
od222756/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification

7

-

-

... More
od222757/2019_2020 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.

7

-

-

... More
od222758/2019_2020 : Supply, installation, testing and commissioning of 2-WAY FIRE BRIGADE inlet connection made of CI Body, 100mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

1

-

-

... More
od222759/2019_2020 : Supply, installation, testing and commissioning of Gun metal Air release valve, 25mm male threaded inlet, complete with all accessories as required as per the technical specification.

2

-

-

... More
od222787/2019_2020 : Providing, fixing, testing & commissioning of UL listed, Standard response, standard coverage upright type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. with all accessories complete as required as per the technical specification.

49

-

-

... More
od222790/2019_2020 : Supply, Installation, Testing and Commissioning of 100mm dia Sprinkler alarm valve of Ductile iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, GI pipe of required size, flanges, orifice plate, gasket etc. complete with all necessary accessories as required for proper functioning as per the technical specification.

1

-

-

... More
od222816/2019_2020 : Supply, installation, testing and commissioning of UL listed flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with IP protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 and operating pressure ranging from 3.5kg/cm2 to 10Kg/cm2. complete as required as per the technical specifications.

1

-

-

... More
PORTABLE FIRE EXTINGUISHER

-

-

-

... More
od222728/2019_2020 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

9

-

-

... More
od222733/2019_2020 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

1

-

-

... More
SIGNAGES

-

-

-

... More
od222729/2019_2020 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

6

-

-

... More
od222730/2019_2020 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

6

-

-

... More
od222739/2019_2020 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

15

-

-

... More
od222741/2019_2020 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

6

-

-

... More
od222742/2019_2020 : Supply and installation of photoluminescent glow signage for "FIRE ASSEMBLY POINT of standard size (500*200 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

2

-

-

... More
FIRE ALARM SYSTEM

-

-

-

... More
od222731/2019_2020 : Supply, Installation, Testing & Commissioning of Conventional Type, 4 zone manual operated Fire Alarm Panel including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module etc. The panel shall have Keypad operation, LCD unit to indicate Fire/ Fault Signal of individual unit, etc complete in all respects as required as per the technical specification. The item shall also include 24 Volts sealed lead acid battery sufficient for 24 hrs back up with battery charger.

1

-

-

... More
od222736/2019_2020 : Supply installation Testing and commissioning of Conventional type Manual Call Point Resettable type via Special Key including back box complete as required as per the technical specification.

6

-

-

... More
od222737/2019_2020 : Providing, installing, testing and commissioning of Conventional type Hooter including base box complete as required as per the technical specification.

6

-

-

... More
od222743/2019_2020 : Supply, installation, testing and commissioning of public address and talk back system consisting of 6 zone public address cum talk back console with mike and selector, multiple channel talk back facility, power supply, battery charger, battery housing, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier, and suitable capacity battery (min 12V), etc. complete as required for meeting the technical specifications.

1

-

-

... More
od222745/2019_2020 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

6

-

-

... More
od222748/2019_2020 : Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

45

-

-

... More
od222751/2019_2020 : Supply and laying of 2x 1.5sq.mm armored Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above ground as per technical specification

1300

-

-

... More
od222753/2019_2020 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

54

-

-

... More
ELEVATOR

-

-

-

... More
od292308/2021_2022 Design, fabrication, supply, installation ,testing and commissioning of machine room less electric traction type, stainless steel 10 Pax passenger (680 Kg) passenger elevator at site (including freight, insurance and all applicable taxes and duties if any etc- except GST ) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, granite flooring, adequate structural steel supports as required for the safe operation of the equipment. LED type emergency light, intercom suitable for hook up to purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with pre-recorded message, LED light fixtures, ventilation fan, etc complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required.brThe traction motor of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification, having automatic centre opening stainless door with stainless steel handrails on two side as applicable in accordance of following details:- 3 stops & 3 openings and entrance & exit at same side and suitable for travel height of 7.5mtrs. (Shaft Size 2150mm x1950mm) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) ,door opening of 800 mm and 2100 mm height. The equipment should be BMS compatible. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.