KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Eprocure
Opening Date29 Jan 2021
Closing Date25 Feb 2021
Tender Amount₹ 13,69,49,222 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

5

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

1638.73

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

48.5

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

496.84

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

1896.96

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

39.36

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

1155.14

-

-

... More
od83339/2020_2021 : Carriage of materials by mechanical transport including loading, unloading and stacking beyond 50 m initial lead up to 5 km, including all lifts involved as directed by the Engineer-in-Charge. Excavated Earth/rock

73.12

-

-

... More
Concrete and Pile Works

-

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

3.3

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

109.34

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

99.24

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

48.79

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .Note : Quantity of cement used in respective item shall be measured for payment . Dosage of water proofing compound shall be 1 kg per bag of cement or as per Manufacturer's recommendation.

86020

-

-

... More
4.13 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

48.79

-

-

... More
od228370/2020_2021 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).(Note: Minimum cement content considered in M-30 is @ 400 Kg/cum as per IS 2911 : 2010 .Nothing extra shall be paid on this account ). 700 mm dia piles

820

-

-

... More
od226343/2020_2021 : Arrangiiles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Routine test (Test Load 1.5 times the Safe capacity =1.5X289 T =433.5 T )

2

-

-

... More
od226344/2020_2021 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Initial test ( Test Load 2.5 times the Safe capacity=2.5X289 T=722.5 Tonne capacity )

1

-

-

... More
RCC Works

-

-

-

... More
od228790/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:-Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting .Nothing extra shall be paid on this account. ) All work upto plinth level

280.89

-

-

... More
od229679/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.Nothing extra shall be paid on this account). All work above plinth level upto floor V level

4.9

-

-

... More
od228792/2020_2021 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting,nothing extra shall be paid on this account).

258.94

-

-

... More
od259581/2020_2021 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.Nothing extra shall be paid on this account). All work upto plinth level.

195.23

-

-

... More
od259582/2020_2021 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting. Nothing extra shall be paid on this account) . All work above plinth level upto floor V level.

1035.19

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, slabs,copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

5.11

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

76384.37

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

140819.86

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

322.19

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1530.74

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

3485.62

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2897.8

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1427.84

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

315.2

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

624

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1284.16

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

3027.02

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

1224.7

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

406.01

-

-

... More
Masonry Works

-

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

53.67

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

156.13

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

369.66

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

40.14

-

-

... More
od226340/2020_2021 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

90.12

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

197.6

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

1291.36

-

-

... More
Flooring Works

-

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

956.48

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

766.84

-

-

... More
11.41.3 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm

816.23

-

-

... More
11.46.3 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800 x 800 mm

790.29

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

24

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

27

-

-

... More
8.9.1.2 : Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade

102.48

-

-

... More
8.12 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

327.6

-

-

... More
od251930/2020_2021 : Providing edge bevelling to 18 mm (approx.) thick granite work etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.

771.8

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

202.43

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

19.83

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

88.13

-

-

... More
od226337/2020_2021 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm (Approx.) of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

229.8

-

-

... More
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

815.55

-

-

... More
Joinery Works

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

8942.95

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

2179.44

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

75.72

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

21.6

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

455.33

-

-

... More
21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness

89.52

-

-

... More
9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710

141.05

-

-

... More
9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

282.09

-

-

... More
od226346/2020_2021 : Providing and fixing glazing with 12mm toughened glass in existing aluminium frame work with EPDM rubber / neoprene gasket.The joints between glass panels and gaps at the perimeter of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof etc. complete as per the architectural drawings and the directions of Engineer-in-charge

4.8

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

2.23

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

106.64

-

-

... More
9.24.1 : Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square

48.48

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

394.2

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

103.32

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

105.2

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

23.23

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

5.81

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

400

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

74

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

50

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

50

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

74

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

178

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

148

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

2

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

39

-

-

... More
od226335/2020_2021 : Providing and fixing steel (white power coated) crescent lock for uPVC /aluminum sliding window/ door with necessary screws etc. complete.

291

-

-

... More
Steel Works

-

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

6558.45

-

-

... More
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

2.4

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

42.33

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

13

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

18.18

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

3.6

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

7146.37

-

-

... More
10.19 : Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

714.64

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

933.12

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

5239.44

-

-

... More
10.27.2 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm

1378

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

2084.16

-

-

... More
od228284/2020_2021 : Providing and fixing corner guard of INPRO make - 160 series or equivalent having vinyl snap-on cover(lead free) of 2mm thickness and aluminium retainer of 2mm thickness that shall be fabricated from 6063-T5 aluminium. Dimensions of corner guard shall be 51mm x 51mm wings and 90 degrees angle. The rigid vinyl profile shall resist an impact of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall not support fungal or bacterial growth in accordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance and shall includes Top and Bottom Caps etc complete all works including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.

120

-

-

... More
od228285/2020_2021 : Providing and fixing crash rails of INPRO make - 1400 series or equivalent having vinyl snap-on cover(lead free) and bumper of 2mm thickness each, and aluminium retainer of 2mm thickness that shall be fabricated from 6063-T5 aluminium. Dimensions of crash rail shall be 102mm height x 25mm depth. The rigid vinyl profile shall resist an impact of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall not support fungal or bacterial growth in accordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance and shall includes End caps etc complete all works including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.

288

-

-

... More
od228286/2020_2021 : Providing and fixing handrail of INPRO make - 800 series or equivalent having vinyl snap-on cover(lead free) of 2mm thickness and aluminium retainer of 2mm thickness that shall be fabricated from 6063-T5 aluminium. Dimensions of handrail shall be 140mm height x 38mm gripping diameter. The system shall resist an impact of 45.5 ft-lbs as per ASTM F-476-84. The rigid vinyl shall not support fungal or bacterial growth in accordance with ASTM G-21 and G-22. System shall meet safety codes with ADA and ANSI compliance. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance and shall includes moulded end returns and mounting brackets etc complete all works including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.

288

-

-

... More
od226333/2020_2021 : Providing and fixing light duty Cast Iron Manhole covers including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by Engineer in Charge. 600x600mm

2

-

-

... More
od230329/2020_2021 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

16

-

-

... More
Ceiling and Roofing Works

-

-

-

... More
50.12.2.5 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

64

-

-

... More
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

229.8

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

149.27

-

-

... More
12.52.3 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.

816.23

-

-

... More
12.52.4 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plaster board having glass fibre conforming to IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of 0.79, with 50 mm resin bonded glass wool backing.

16.43

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

114.25

-

-

... More
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)

6.6

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).

64

-

-

... More
Finishing Works

-

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

8624.77

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

1975.59

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

5664.33

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

5140.98

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

10507.12

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

342.82

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

4155.28

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

93.13

-

-

... More
13.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)

26.66

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

507.01

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

10047

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

26.66

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

229.8

-

-

... More
14.70 : Melamine polishing on wood work ( one or more coat)

76.35

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

227.52

-

-

... More
od229985/2020_2021 : Supply and application of two coats of White cement based waterproof cement putty with visible water repellancy, very high anti-efflorescence and excellent finish, to make even and smooth finish after pre wetting substrate. Sanding of applied waterproof Putty Surface with emry paper / sand paper above 280 / 320. Application of 1/2 coats of Silicon based Seal-O-Prime or approved equivalent (IGBC/GRIHA certifed best quality primer) with sealer properties having anti-algae and alkali resistance properties & damp resistancewith 40% dilution with potable water. Application of 3 coats of water based PU with minimum VOC and very less odor having better sheen, finish and film integrity along with anti-algae, antifungal, anti-microbial and high washable with high stain resiatance should comes under clean room coating requirements.Surface shall be Inspected to check ideal moisture level and pH value of the surface before painting. Surface Prepration with dust removal and sand papering with hand held sanding machine for repainting surface and scrapping new substarte with metal plate called paint scrapper to make smooth and ideal surface for painting .The rate shall include cost and conveyance of all material ,labour charges, lead etc. complete as directed by Engineer - in- charge. (All works covered by this specification shall be carried by an experienced agency having sufficient experience in this type of painting system Only skilled and experienced persons shall be employed for this purpose.)

174.69

-

-

... More
Demolition Works

-

-

-

... More
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)

61.04

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

124.37

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

174.91

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

60

-

-

... More
15.12.2 : Of area beyond 3 sq. metres

1

-

-

... More
15.14.1 : Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above

1.19

-

-

... More
15.14.2 : Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area below 40 square centimeters

210.66

-

-

... More
15.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

5012.04

-

-

... More
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet

105.82

-

-

... More
15.28.2 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet

16.2

-

-

... More
15.40.1 : Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead:Thickness upto 40 mm

19.58

-

-

... More
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

83.82

-

-

... More
od163871/2019_2020 : Demolishing solid block/ brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. In cement mortar

263.79

-

-

... More
od164139/2019_2020 : Dismantling tile work in walls, floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm

723.61

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

447.2

-

-

... More
Paving Works

-

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

8

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

340

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

340

-

-

... More
16.83 : Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

172.74

-

-

... More
16.84 : Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)

172.74

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern.

1360

-

-

... More
Water Proofing Works

-

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

194.4

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

365.57

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

416.48

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.

1090.91

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

68

-

-

... More
Miscellaneous Works

-

-

-

... More
19.6.4 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia R.C.C. pipe

36

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.56

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.56

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.56

-

-

... More
SANITARY WORKS

-

-

-

... More
od210762/2019_2020 : Providing and fixing vitreous china counter wash basin of approved make including one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia rubberplugs 32 mmdia CP brass waste coupling, 32 mm dia CP brass bottle trap,CP brass 15mm anglevalve,completeincluding CI/MS brackets duly painted, nuts, washers, etc. complete,cost andconveyance ofall materialslabour charges ,lead, lift necessary wall cutting / chasing and making good thewalls,floors,slab,testingand commissioning to the satisfaction of Engineer in charge at all levels(Modelno:Hindware 10065/CeraS2030103SN+ Jaquar CON CHR 011KN+ Jaquar ALD CHR 769L250+Jaquar AQT CHR 3057+ Jaquar ALD CHR 709 or equivalent)

25

-

-

... More
17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

15

-

-

... More
17.78 : Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.

8

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

29

-

-

... More
od210763/2019_2020 : Providing and fixing floor trap with cockroach trap (multi trap), SS304 grade floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels

60

-

-

... More
od210765/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.75mm dia

18

-

-

... More
od210766/2019_2020 : Providing and fixing CP brass robe hook etc complete testing and commissioning to the satisfaction of Engineer at all levels.The rate is including cost and conveyance of all materials,labourcharges, lead,lift ,cutting and making good the walls,floors,slab etc complete as directed by theEngineer incharge at all levels. Models-Jaquar ACN CHR 1191N or equivalent)

28

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

46

-

-

... More
od210768/2019_2020 : Providing and fixing of star white vitreous china urinal division plate of approved quality and make with fittings/fastener including cutting and making good the walls,floors,slab,cost and conveyance ofall material, labour charge, lead, lift etc. complete as directed by theEngineer in charge atall levels.(Model:Hindware catalogue no: F61001 or equivalent)

15

-

-

... More
od210769/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.110mm dia

18

-

-

... More
od210774/2019_2020 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin,one pair mounting brackets,one number pillar cock all other related fittings like bottletrap,anglecock,waste coupling, etc,one number EWC and Cistern complete with fittings seat cover,one no.hinged rail76cm ;4nos. of grab rails 60cm etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing andas directed by Engineer in charge. (Model no: Hindware Matrix/ Cera Cruise +Jaquar CON CHR 011KN+ Jaquar ALD CHR 769L250+Jaquar AQT CHR 3057+ Jaquar ALD CHR 709 or equivalent as approved by the Engineer in charge at all levels)

3

-

-

... More
od210777/2019_2020 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels

6

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

8

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

8

-

-

... More
od210781/2019_2020 : Providing and fixing sink cock of approved quality conforming to IS: 8931.Model Jaquar FLR-CHR-5347N or equivalent

4

-

-

... More
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brasspillar taps

20

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

7

-

-

... More
od291975/2019_2020 : Providing and fixing premium quality C.P. brass overhead shower 4 inch dia with wall flange and shower arm of approved make and model including cost of all materials, labour etc complete as directed by the Engineer in Charge at all levels.(Models:Jaquar catalogue no: OHS-CHR-1989GD+SHA-CHR-477 or equivalent)

4

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jaquar or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

28

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

76

-

-

... More
17.22A : Providing and fixing CP Brass 32mm size Bottle trap of approved quality & make and as per the direction of Engineer in charge.

20

-

-

... More
od210931/2019_2020 : Providing and fixing water heater of approved MOC,quality and make of storage capacity 25 litre including cost and conveyance of all materials labour charges ,lead, lift,cutting and making good the walls,slabs,floors wherever required as per direction of Engineer-Incharge at all levels(Models:Jaquar catalogue no:Elena or equivalent)

4

-

-

... More
od289891/2020_2021 : Providing and fixing water heater of approved MOC, quality and make of storage capacity 6 litre including cost and conveyance of all materials labour charges ,lead, lift, cutting and making good the walls, slabs, floors wherever required as per direction of Engineer-In charge at all levels(Models: Jaquar catalogue no: Elena or equivalent)

4

-

-

... More
od291989/2019_2020 : Providing and fixing Stainless Steel A ISI 304 (18/8) 2 station Scrub sink of approved shape and size with elbow operated sink cocks as per IS 13983 with C.I. brackets and stainless steel plugs 40 mm,along with soap dispenser including painting of fittings and brackets, cutting and making good the walls etc complete as per the requirements of the site in charge including cost of conveyance, testing, commissioning, installation etc.

2

-

-

... More
od203732/2020_2021 : Providing and fixing C.P. brass concealed stop cock (control valve) of standard design and of approved make conforming to IS:8931 etc. complete, testing and commissioning to the satisfaction of Engineer in Charge at all levels,20 mm nominal bore.(Models:Jaquar ALD-CHR-089CQT+CQT-CHR-23083K or equivalent)

6

-

-

... More
od203892/2020_2021 : Providing & fixing star white vitreous china flat back urinal with CP brass flush valve,auto closing system with control cock and wall flange of approved size with all accessories toprovide satisfactory functioning including cost and conveyance of all materials, labour charges ,lead,necessary wall cutting / chasing and making good the walls,floors,slab, as required for urinal flushing etccomplete, testing and commissioning to the satisfaction of Engineer in charge at all levels. (Model:(Jaquar ORP10053PM/ Kohler K5017INERO + Jaquar PRS077) or equivalentas approved by the Engineer in charge at all levels

12

-

-

... More
od203938/2020_2021 : Providing and fixing CP brass shower mixer with wall flanges and all necessary accessories testing and commissioning etc to the satisfaction of Engineer in Charge at all levels.Models: (Jaquar FUS 29267 or equivalent)

4

-

-

... More
od232521/2020_2021 : Providing and fixing CP brass elbow operated basin mixer of approved quality and make as directed by the Engineer in charge at all levels (Models: Jaquar FLR-CHR-5033B or equivalent) as instructed by the Engineer in charge at all levels

4

-

-

... More
WATER SUPPLY AND SANITARY

-

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

120

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

72

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

39

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

33

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

42

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

5

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

10

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

10

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

15

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

10

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

4

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

6

-

-

... More
od210775/2019_2020 : Supply and erection of dual media filter of size 0.6m dia x 1.2 m HOS, (approx.) vertical type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness, 6mm dish thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves and graded pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure, back wash arrangement, etc and all other accessories. Flow rate - 5 m3/hr

1

-

-

... More
od210776/2019_2020 : Providing and fixing cast iron fabricated Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges as per standards etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge at all levels 50mm Y type strainer

3

-

-

... More
od210778/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge 65mm Dia

6

-

-

... More
od210779/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

6

-

-

... More
od210782/2019_2020 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

5

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

10

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

12

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

60

-

-

... More
od210789/2019_2020 : Supplying and installing activated carbon filter of size 5 cum/hr with internally and externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at inlet and outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, V-notch Board etc and all other accessories .The rate shall include cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od210792/2019_2020 : Chemical dosing system:Supplying and fixing of electronic dosing pump with all wetted parts in PP construction suitable for pumping HOCl solution including cost of valves, suction and delivery lines using heavy duty PVC tubes, FRP tank of 80 litres capacity, FRP motor cover etc. and complete with all accessories.Capacity : 6 lph @ 3.5 kg/cm2

1

-

-

... More
od210794/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 100mm dia

10

-

-

... More
od210795/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 80mm dia

6

-

-

... More
od210796/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 65mm dia

6

-

-

... More
od210797/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 100mm dia

8

-

-

... More
od210798/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 80mm dia

8

-

-

... More
od210800/2019_2020 : Supply and installation of water level indicator with electronic integrated circuit and necessary accessories etc complete as directed by the Engineer in charge at all levels

7

-

-

... More
od210801/2019_2020 : Supplying,installing, testing and commisioning of electronic integrated circuits and wireless water level controller including necessary cabling and transformers with all accessories etc complete as directed by Engineer in charge for water supply level control in water tanks

7

-

-

... More
od210802/2019_2020 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm dia

16

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

120

-

-

... More
od210803/2019_2020 : Providing and fixing CI Y type strainer 65mm dia rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials labour etc. complete and as directed by Engineer-in-Charge at all levels

3

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal bore Horizontal

2

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

6

-

-

... More
od210807/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 80 mm nominal dia pipes

30

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

48

-

-

... More
18.31.1.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II

6

-

-

... More
od210808/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 65 mm nominal dia pipes

84

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

5

-

-

... More
od210812/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 100 mm nominal outer dia pipes

30

-

-

... More
2.10.1.3 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

30

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

20

-

-

... More
18.19.6.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreHorizontal

2

-

-

... More
od210836/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 50mm dia

3

-

-

... More
od210839/2019_2020 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 300 mm dia RCC pipes.

30

-

-

... More
19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

30

-

-

... More
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore

1

-

-

... More
18.61.1 : Providing and fixing C.I dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :80 mm dia

1

-

-

... More
od210840/2019_2020 : Supplying, fixing and commissioning of centrifugal pump of CI construction, CI impeller complete with motor,working with 415 V, 3 pH, 50 Hz including base plate foundation bolts, nuts, pressure gauge, priming arrangements and all accessories. Capacity : 8 to 32 cum/hr, Head : 21 to 51 metre

2

-

-

... More
od210841/2019_2020 : Supplying, fixing and commissioning of centrifugal pump of CI construction, bronze impeller complete with motor,working with 415 V, 3 pH, 50 Hz including base plate foundation bolts, nuts, pressure gauge, priming arrangements and all accessories. Capacity :5 cum/hr, Head : 35 metre

2

-

-

... More
od210842/2019_2020 : Supplying ,fixing, testing and commissioning of portable drainage pump with 12mm solid handling, with stainless steel construction, stainless steel impeller complete with motor , with carrying handle and all accessories and working with 415V, 3ph and 50 Hz frequencyCapacity:10m3/hour,Head-15m

1

-

-

... More
od210844/2019_2020 : supplying and fixing centrigugal pump with CI construction,Ci impeller complete with motor,base plate,foundation ,bolts,nuts,pressure gauge and all accessories and working with 415v,3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by engineer in charge Discharge 7 to 15m3/hr ;Head: 36 to 51m

2

-

-

... More
od210858/2019_2020 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. complete.150 mm dia RCC pipes.

30

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

18

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

18

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

18

-

-

... More
od292118/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.40 mm nominal outer dia pipes

18

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

60

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

184

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

369

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

18

-

-

... More
od229636/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - Internal work- Exposed on wall

286

-

-

... More
od229637/2020_2021 : Supplying and fixing GI 8mm dia threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.

820

-

-

... More
od229638/2020_2021 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 160 mm dia 6 Kgf/cm2

171

-

-

... More
od229639/2020_2021 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110 mm dia 6 Kgf/cm2

307

-

-

... More
od229640/2020_2021 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/cm2

30

-

-

... More
od229642/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

15

-

-

... More
od229643/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

143

-

-

... More
od229644/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings &specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

30

-

-

... More
od229645/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

294

-

-

... More
od229646/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 kgf/cm2

634

-

-

... More
od229647/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110mm pipe 6 kgf/cm2

84

-

-

... More
od232553/2020_2021 : Supplying and fixing of submersible grinder sewage pump, with Stainless steel construction, Stainless steel impeller complete with nuts, pressure gauge and all accessories and working with 415V, 3ph and 50 Hz frequency complete with control panel including starter, breakers, timers, contactors, indication lamps and all accessories as required complete as directed by the Engineer in charge at all levels.Capacity:5 to 15m3/hr,Head :5 to 15m

1

-

-

... More
od232560/2020_2021 : Supplying, laying, jointing and hydrostatically testing ISI marked HDPE pipes of 110mm dia 10 kg/cm2 conforming to as per IS 4984,1985 PE-100 including all fittings and specials such as tees, elbows, bends, reducers, end caps, saddles, plugs,coupling, MTA , all types of pipe supports etc.including cost of all jointing materials, bolts, nuts, rubber washers, ferrule, pipe supports, hire of tools, cost for conveyance of water for testing, etc. complete so as to withstand the internal design pressure of 10 kg/cm2 -Exposed

3

-

-

... More
od232561/2020_2021 : Supplying, laying, jointing and hydrostatically testing ISI marked HDPE pipes of 10 kg/cm2 conforming to as per IS 4984,1985 PE-100 including all fittings and specials such as tees, elbows, bends, reducers, end caps, saddles, plugs, coupling, MTA etc. including cost of all jointing materials, bolts, nuts, rubber washers, ferrule, pipe supports, hire of tools, cost for conveyance of water for testing, etc. complete so as to withstand the internal design pressure of 10 kg/cm2 etc. complete for external works as directed by Engineer-in-Charge at all levels. 110 mm dia pipe

12

-

-

... More
CABLES AND ACCESSORIES

-

-

-

... More
od261720/2020_2021 : Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date 3C X 185 sq.mm

110

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

60

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

40

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

10

-

-

... More
od261771/2020_2021 : Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 185 sq. mm

1

-

-

... More
od261772/2020_2021 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 185 sq. mm

1

-

-

... More
od261773/2020_2021 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required 185 sq. mm

2

-

-

... More
od210020/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 2C 10 Sq.mm Al

50

-

-

... More
od210034/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 2.5 sqmm Cu

297

-

-

... More
od210042/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 16 Sq.mm Al

264

-

-

... More
od210044/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 35 Sq.mm Al

539

-

-

... More
od210061/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 400 Sq. mm Al

517

-

-

... More
od210574/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 12C 1.5 sqmm Cu

99

-

-

... More
od210575/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated FR, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 300Sq.mm Al

50

-

-

... More
od210577/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated FR, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 120 Sq.mm Al

198

-

-

... More
od79444/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 3C 4 sqmm Cu

205

-

-

... More
od184523/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 185 Sq. mm Al

220

-

-

... More
od184530/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, unarmoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 10 Sq.mm Cu Unarmored

132

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
od79445/2020_2021 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3C 4Sq.mm Cu

22

-

-

... More
od210590/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 12C 2.5 sqmmCu

4

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

18

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

20

-

-

... More
od210761/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated FR, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 10 Sq.mm Al

308

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

24

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

2

-

-

... More
od210083/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4C 2.5 sqmm Cu

20

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

4

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

26

-

-

... More
od184549/2020_2021 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 4C 10 Sq.mm Cu

8

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

398

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

60

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

100

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

30

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

5

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

100

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

5

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

5

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

10

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

5

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

5

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

5

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

224

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

22

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

37

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1079

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

336

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

270

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

200

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

50

-

-

... More
od210085/2019_2020 : Providing, laying and fixing following dia RCC pipe NP 4 class (heavy duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching upto 1.5 m depth and refilling etc. as required 300 mm dia

10

-

-

... More
od210086/2019_2020 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 600 mm width X 50 mm depth X 2.0 mm thickness

70

-

-

... More
od210087/2019_2020 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 300 mm width X 50 mm depth X 1.6 mm thickness

70

-

-

... More
od210088/2019_2020 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 450 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
od210089/2019_2020 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required 150 mm width X 50 mm depth X 1.6 mm thickness

130

-

-

... More
od211627/2019_2020 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 300 MM WIDTH X 50 MM DEPTH X 2 MM THICK

20

-

-

... More
od211628/2019_2020 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 450 MM WIDTH X 50 MM DEPTH X 2 MM THICK

20

-

-

... More
od210090/2019_2020 : Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke & Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable

4.05

-

-

... More
od210091/2019_2020 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

500

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.

20

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
od230661/2020_2021 : Group controlled light point with 1.5 sq. mm wire - Wiring for Group controlled light point (from one point to another point) with 3X 1.5 sq. mm PVC insulated, (FRLS), copper conductor cable in existing surface/recessed mounted rigid medium class 20mm PVC conduit with all accessories as required.(If length exceeds 5 m , It will be measured under wiring item)

95

-

-

... More
od230662/2020_2021 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(If length exceeds 5 m , It will be measured under wiring item)

2

-

-

... More
od230663/2020_2021 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required (If length exceeds 5 m , It will be measured under wiring item)

481

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

10149

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

7725

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

4000

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

2

-

-

... More
1.24.2 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

2

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

6

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

3

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

6

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

10

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

5

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

100

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

70

-

-

... More
od210049/2019_2020 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

35

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).

151

-

-

... More
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

70

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

10

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

4059.6

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

17322.4

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
od210064/2019_2020 : Supply and laying of UPVC DLP cable management system of size 110mmx60mm along with all accessories such as flexible cover, base joint, end cap, flat angles, flat junctions, external angles etc as required complete.

200

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
od209998/2019_2020 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required 8 way (8 + 24), Double door

3

-

-

... More
od210007/2019_2020 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required 4 way (8 + 12), Double door

1

-

-

... More
od210011/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel,duly powder painted, inclusive of suitable tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s (but without MCB s and incomer ) as required 8 way (8 + 24), Double door

6

-

-

... More
od210015/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, duly powder painted, inclusive of suitable tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s (but without MCB s and incomer ) as required 4 way (8 + 12), Double door

6

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

... More
od210019/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 40 amps. (415 Volts),30mA sensitivity

2

-

-

... More
od210023/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 63 amps. (415 Volts),100mA sensitivity

9

-

-

... More
od210030/2019_2020 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required 6 A to 32 A TP MCB, D-CURVE

2

-

-

... More
od210032/2019_2020 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required 40A to 63A, TP,C-Curve MCB

22

-

-

... More
od210033/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 2 pole 25 amps. (240 Volts), 30mA sensitivity

1

-

-

... More
od210035/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 25 amps. (415 Volts),30mA sensitivity.

12

-

-

... More
od210037/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 40 amps. (415 Volts), 100mA sensitivity

7

-

-

... More
od261709/2020_2021 : Supplying and fixing following rating, single pole, 230 volts, 100mA RCBO in the existing MCB DB complete with connections, testing and commissioning etc. as required 16 amps

6

-

-

... More
od261710/2020_2021 : Supplying and fixing following rating, triple pole, 415 volts, 100mA RCBO in the existing MCB DB complete with connections, testing and commissioning etc. as required 25 amps

14

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

242

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

37

-

-

... More
od210050/2019_2020 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required 6A to 32A ,SP D curve

108

-

-

... More
od210053/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 12 way double door horizontal type SPN DB

1

-

-

... More
od210055/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 4 way double door horizontal type TPN DB

1

-

-

... More
od210058/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 8 way double door horizontal type TPN DB

3

-

-

... More
od210062/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for vertical TPN DB (MCB incomer)

12

-

-

... More
od185506/2020_2021 : Supplying and fixing following way,cable end box with all accessories as required compete for the following DBs 6 way double door horizontal type TPN DB

15

-

-

... More
od185507/2020_2021 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (8 + 18), Double door

15

-

-

... More
od210072/2019_2020 : Supplying and fixing FP sheet steel enclosure on surface/ recess all accessories required complete

4

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

5

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

2

-

-

... More
2.17 : Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

18

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

50

-

-

... More
od80952/2020_2021 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

9

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od209980/2019_2020 : Supply of industrial surface mounted LED batten and lamp with Poly Carbonate Body and PolyCarbonate Diffuser, along with driver , surge protector, maximum system wattage of 20 Watts,lumen output of lamp greater than 2000 lumen, power factor= 0.9, cool day light and including all necessary accessories as required complete.Make:- Cat No: Wipro LE20-491-XXX-57-XX or equivalent approved make

5

-

-

... More
od209991/2019_2020 : Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,system wattage of 40+/-4 Watts(2x20 watts),lumen output of lamp greater than 3600 lumen, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 90lumen/watt and including all necessary accessories as required complete.Make:- PHILIPS BN308C LED40S-6500 L120 PIR WH or WIPRO LE20-491-XXX-57-G1 or CGLPFC-36-CDLL or equivalent approved make

10

-

-

... More
od185511/2020_2021 : Supply of indoor decorative industrial surface mounted LED tube with Batten along with driver , surge protector,,system wattage of maximum 40Watts,lumen output of luminaire greater than 4000 lumen, power factor 0.95, THD;10%,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24

60

-

-

... More
od209995/2019_2020 : Supply of recess mounted LED panel light fixture light made of CRCA with corrosion resistance p[owder coating and with proper diffusers, along with driver,system wattage of 36 +/- 2 Watts with lumen output of lamp not less than 3600 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- CG LCTLN/RN/36/CDL or equivalent approved make

23

-

-

... More
od210001/2019_2020 : Supply of surface mounted LED panel light fixture light made of CRCA sheet with corrosion resistance powder coating, along with driver,system wattage of 36 +/- 3Watts with lumen output of lamp not less than 3600 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No:Wipro:Immaculated LED or equivalent one)

40

-

-

... More
od210006/2019_2020 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser,along with driver,system wattage of 10+/-2 Watts,lumen output of lamp greater than 800, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 80lumen/watt and including all the necessary accessories as required complete.Make:- PHILIPS BN 021 LED10S- 6500 PSU GR S1 or WIPRO LL20-111-XXX-65NE3 or CG LCTL 9 CDL or equivalent approved make

16

-

-

... More
od210010/2019_2020 : Supply of 10+/-2w LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP65 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required. (Make:Crompton LBH-10-CDL or equivalent approved make)

9

-

-

... More
od210014/2019_2020 : Supply of cleanroom grade Bottom openable type LED panel light fixture light made of die cast aluminium with corrosion resistance p[owder coating, along with driver and with proper diffusers,system wattage of 40 +/- 2 Watts with lumen output of lamp not less than 4000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- PHILIPS CR652B LED56S CR CW CA or WIPRO LC20-551-XXX-57-XX or CG LCBOR-40-CDL equivalent approved make

39

-

-

... More
od210017/2019_2020 : Supply of high efficient surface downlighter made of die cast aluminium along with driver,system wattage maximum of 18+/-3 Watts,lumen output of lamp greater than 1400 lumens, power factor 0.9,rated life of L70 @ 50,000 hours with suitable driver and including all necessary accessories as required complete.(Make - Wipro LD80-171-XXX-60-SM or equivalent approved make)

5

-

-

... More
od210022/2019_2020 : Supply of LED recess mounted down light made of die cast aluminium with proper diffusers, along with driver,system wattage of 18+/-2 Watts,lumen output of lamp greater than 1800 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- PHILIPS DN 395B LED20S-6500 PSU WH or WIPRO LD901-231-XXX-65-XX or CG LCDN-18-CDLL or equivalent approved make

141

-

-

... More
od210025/2019_2020 : Supply of LED recess mounted down light made of die cast aluminiumwith proper diffusers, along with driver,system wattage of 30+/-2 Watts,lumen output of lamp greater than 1000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- CG CDR-216-30-57-SL-NWHor equivalent approved make

2

-

-

... More
od210027/2019_2020 : Supply of 50W flood light fixturemade of die cast aluminium with corrosion resistance powder coating, along with driver and with proper diffusers,system wattage of 50 +/- 2 Watts with lumen output of fixture not less than 5000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- CG LFL-50-CDL/60-M equivalent approved make

2

-

-

... More
od210031/2019_2020 : Supply of cleanroom grade Bottom openable type LED panel (1X4) light fixture light made of die cast aluminium with corrosion resistance p[owder coating, along with driver and with proper diffusers,system wattage of 40 +/- 2 Watts with lumen output of fixture not less than 4000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- PHILIPS CR652B LED56S CR CW CA or WIPRO LC20-551-XXX-57-XX or CG LCBOR-40-CDL equivalent approved make

5

-

-

... More
od210038/2019_2020 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)

31

-

-

... More
od79557/2020_2021 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc complete as required

68

-

-

... More
od210039/2019_2020 : Supply of 450 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.(Make: CG Vortex air circulator 450mm or equivalent approved make)

6

-

-

... More
od210045/2019_2020 : Supply of indoor industrial decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser ,along with driver,system wattage of 20+/-2 Watts, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 90lumen/watt and including all the necessary accessories as required complete.Make:-wipro Optima 20W or equivalent approved make

42

-

-

... More
od210051/2019_2020 : Supply of 380 mm sweep heavy duty exhaust fan in die cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton EXHD-380-6-1 or equivalant approved make)

4

-

-

... More
od211637/2019_2020 : Supply of LED recess mounted down light made of die cast aluminiumwith proper diffusers, along with driver,system wattage of 10+/-2 Watts,lumen output of lamp greater than 1000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- PHILIPS DN 392B LED10S-6500 PSU WH or WIPRO LLD90-111-XXX-65-XXor equivalent approved make

87

-

-

... More
od231399/2020_2021 : Supply,installation , testing and commissioning of suspended type medium bay LED linear light fixture made of die cast aluminium with corrosion resistance powder coating and with proper diffusers, along with driver,maximum system wattage of 40 Watts with lumen output not less than 4000 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- WIPRO LE23-491-XXX-57-XX or equivalent approved make. All accessories required for suspending the fixture upto 1m depth is in scope of this item

4

-

-

... More
ITC LIGHT FITTINGS AND FANS

-

-

-

... More
od209981/2019_2020 : Installation, testing and commissioning of Wall fan, including all the supports as required and wiring using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc complete

6

-

-

... More
od209992/2019_2020 : Installation, testing and commissioning of LED fittings with GI chain - Installation testing and commissioning of prewired fluorescent / LED fittings of all types complete with all accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor cable as required.

62

-

-

... More
od209994/2019_2020 : Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required

230

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

180

-

-

... More
1.47 : Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

50

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

33

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

568

-

-

... More
od211620/2019_2020 : Installation, testing and commissioning of High bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required

2

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

10

-

-

... More
od210047/2019_2020 : Supply and providing ISI marked electrical 3.3 /11 kV grade anti-skid rubber mat 2mx1mx2.5 mm thick

4

-

-

... More
od210048/2019_2020 : Supply and providing ISI marked electrical 3.3 /11 kV grade anti-skid rubber mat as per IS:15652.for the 2m x 1m x 2mm size

7

-

-

... More
od210054/2019_2020 : Supply and fixing anodised aluminum glass framed shock treatment chart

2

-

-

... More
od210056/2019_2020 : Supplying of Rubber hand gloves suitable for 11 KV

1

-

-

... More
od210057/2019_2020 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

2

-

-

... More
od210059/2019_2020 : Supplying of Rubber hand gloves suitable for 1.1 KV

2

-

-

... More
od80869/2020_2021 : Supply and fixing of First aid box

1

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
od210065/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 4.00 mm GI conductor (8 SWG)

205

-

-

... More
od210066/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 3.15mm Cu (10 SWG)

11

-

-

... More
od210067/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 25mm X 3 mm Cu

46

-

-

... More
od210069/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 50x10 mm GI

104

-

-

... More
od210074/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required 50x10 mm GI

132

-

-

... More
od210075/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required 25mm X 3 mm Cu

31

-

-

... More
od210076/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required 3.15mm Cu (10 SWG)

241

-

-

... More
od210077/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required 4.00 mm GI conductor (8 SWG)

37

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

25

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

481

-

-

... More
od210378/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required Cu conductor (4 SWG)

50

-

-

... More
od210379/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required Cu conductor (6 SWG)

200

-

-

... More
od210079/2019_2020 : Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing masonry enclosure with heavy duty CI cover plate of 300X300 mm having locking arrangement

15

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
od209984/2019_2020 : Supply and Fixing of 8 mm Aluminum Round Conductor as horizontal air terminal with the required mounting clamps , cross connectors, T connectors ,glue, expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on sheet roof

50

-

-

... More
od209987/2019_2020 : Supply and Fixing of 8 mm Aluminum Round Conductor as horizontal air terminal with the required mounting clamps , cross connectors, T connectors , expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on parapet

211

-

-

... More
od209993/2019_2020 : Supply and Fixing of 8 mm Aluminum Round Conductor as vertical down conductor with the required mounting clamps , cross connectors, T connectors ,expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on surface as needed

210

-

-

... More
od210002/2019_2020 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 30 X 3 GI strip

6

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

174

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
od210412/2019_2020 : Supply, installation, testing and commissioning of 6m single arm long Hot dipped GI pole painted with PU coat with built- in control box prewired, with pole suitable for mounting one number of LED luminairie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, and all other accessories. complete including necessary civil foundation. Along with LED Lamp with die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 45(+/-10) watts, lumen outputnot less than than 4500 lumen, System efficacy not less than 100 lumen per watt ,power factor= 0.9, IP 66 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.( Luminairie Make: Wipro Skyline LR02-501-XXX-57-G1 or or LT Adornis min -or equivalent approved make)

7

-

-

... More
LT PANEL BOARD AND ACCESSORIES

-

-

-

... More
od210210/2019_2020 : Utility panel SITC of LT Switch Board, cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm havingCPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction Instruments RYB Indicating lamps LED type, (0-500)V Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch ,Voltmeter selector switch , 5 VA Class 1 CTs for metering, Digitalmultimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram Incomer 125 A FP MCCB with adjustable thermal magnetic release with OL & SC protection .- 1 no 125 A TPN busbar chamber with Aluminium busbar Out goings 63A TP+NL MCCB with adjustable thermal magnetic release with OL & SC protection.- 7nos Pluggable type surge arrester Type-2 as per IEC 61643 (IP 20)-1 set The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per Single line diagram and technical specification

1

-

-

... More
od210211/2019_2020 : Lighting And Power Panel SITC of LT Switch Board, cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm havingCPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction Instruments RYB Indicating lamps LED type, (0-500)V Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch ,Voltmeter selector switch , 5 VA Class 1 CTs for metering, Digitalmultimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram,Pluggable type surge arrester Type-2 as per IEC 61643 (IP 20)-1 set Incomer 250 A FP MCCB with adjustable thermal magnetic release with OL & SC protection .- 1 no 250 A TPN busbar chamber with Aluminium busbar Out goings 63 A TP+NL MCCB with adjustable thermal magnetic release with OL & SC protection.- 10nos The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per Single line diagram and technical specification

1

-

-

... More
od210212/2019_2020 : APFC PANEL 110KVAR SITC of LT Switch Board (110kVAR APFC), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm havingCPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. There shall be compartmentalisation between breakers and functional units as well as busbars and cables Incomer 320 A FP Moulded Case Circuit Breaker with thermal release and neutral link .- 1no Instruments RYB Indicating lamps LED type, Microprocessor based intelligent, 10 step IPFC relay with PF display and necessary accessories,(0-500)V Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch ,Auto / manual selector switch,ON-OFF -TRIP indication lamp -, Voltmeter selector switch , 5 VA Class 1 CTs for metering, Digitalmultimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram Busbar 320 A TPN busbar chamber with Aluminium busbar Outgoing 63A, 25kA, TP+NL, MCCB with adjustable thermal magnetic release with OL & SC protection - 4 no 25A, 25kA, TP+NL, MCCB with adjustable thermal magnetic release with OL & SC protection - 4 nos 16A, 25kA, TP+NL, MCCB with adjustable thermal magnetic release with OL & SC protection - 2 nos 20 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -3 No 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -3Nos 5kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2Nos 20 kVAr,480-520 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 3Nos 10 kVAr,480-520 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 4 Nos 5 kVAr,440-520 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2Nos Control wiring required for no load compensation capacitor Pluggable type surge arrester Type-2 as per IEC 61643 (IP 20)-1 set The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per Single line diagram and technical specification

1

-

-

... More
od210213/2019_2020 : PUMP PANEL SITC of LT Switch Board (PUMP PANEL), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm havingCPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction Instruments RYB Indicating lamps LED type, (0-500)V Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch ,Voltmeter selector switch , 5 VA Class 1 CTs for metering, Digitalmultimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram Incomer 63A FP Moulded Case Circuit Breaker with thermal release .- 1no 63A TPN busbar chamber with Aluminium busbar Out goings 25A TP MPCB -5 Nos 10A TP MPCB -3 Nos 6.3A TP MPCB -3 Nos FA STAR DELTA STARTER for 3 phase, 50Hz motor of 7.5HP capacity with ON/OFF LED Indication lamps, Start / Stop push buttons ,TP OLR with SPP, TP AC3 duty contactors , timer etc. - 4 Nos DOL STARTER for 3 phase, 50Hz motor of 5HP capacity with ON/OFF LED Indication lamps, Start / Stop push buttons ,TP OLR with SPP, TP AC3 duty contactors etc. - 1 Nos DOL STARTER for 3 phase, 50Hz motor of 3HP capacity with ON/OFF LED Indication lamps, Start / Stop push buttons ,TP OLR with SPP, TP AC3 duty contactors etc. - 2 Nos Spare outlets, ON OFF indication LEDs, capacitors,start stop push buttons etc. shall be provided as per Single line diagram The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per Single line diagram and technical specification

1

-

-

... More
od210214/2019_2020 : MSB SITC of LT Switch Board , cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction Instruments RYB Indicating lamps LED type, (0-500)V Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch ,Voltmeter selector switch , 5 VA CTs for metering & IPFCR , Digital multimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram Incomer 800A, Four pole, 50 KA, Electrical Draw Out type ACB with microprocessor based adjustable overcurrent and earthfault release, RS 485 communication facility - 2 No. 800A TPN busbar chamber with Aluminium busbar ATS with AMF facility- 1 No Out goings 250A TP+NL MCCB with adjustable thermal magnetic release with OL & SC protection.- 5 nos 160A TP+NL MCCB with adjustable thermal magnetic release with OL & SC protection- 2 nos 125A TP+NL MCCB with adjustable thermal magnetic release with OL & SC protection- 3 nos 320 A, TPN, SDU - 1 Nos Pluggable type surge arrester Type-1 as per IEC 61643 (IP 20)-1 set ; br>The main panel shall have space provision to incorporate CO2 flooding system ( Fire protection) as per NBC 2016 All control wiring between DG sets, transformers and MSB shall be ocnsidered in the scope of this item The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per Single line diagram and technical specification

1

-

-

... More
od80547/2020_2021 : HVAC Panel SITC of LT Switch Board (HVAC Panel-IDU), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm havingCPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4b Construction Instruments RYB Indicating lamps LED type, (0-500)V Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch ,Voltmeter selector switch , 5 VA Class 1 CTs for metering, Digitalmultimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram Incomer 250 A FP MCCB with adjustable thermal magnetic release with OL & SC protection .- 1no 250 A TPN busbar chamber with Aluminium busbar Out goings 63A TP+NL MCCB with adjustable thermal magnetic release with OL & SC protection(Ics =100%Icu= 35KA).- 4 nos 40A TP+NL MCCB with adjustable thermal magnetic release with OL & SC protection (Ics =100%Icu= 35KA).- 3nos The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per Single line diagram and technical specification

1

-

-

... More
HT EQUIPMENTS

-

-

-

... More
od210258/2019_2020 : 400 KVA 11KV UNITISED SUBSTATION Design, fabrication, supply,installation testing & commisioning of indoor type Packaged (Unitized) Substation enclosure consiting 400 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP23 enclosure, winding temperature alarm and trip, necessary louvers,all standard fittings and accessories, LV chamber suitable for termination of cables, necessary power and control cabling for alarm, tripping indication, all required internal cabling etc complete and as per specifications in all respects.The rate shall be inclusive of all materials, lead, lift etc. complete as per single line diagram technical specification. Minor civil works included in the scope HT Compartment 11kV, 630A, 21kA VCB for 3 sec with spring charging motor , tripping coil and closing coil -1 No 630 Amp continously rated Al busbar Self powered microprocessor based three phase over current and earthfault relay with protection CTs - 1 set Transformer Compartment 400 kVA, 11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -5% in steps of 2.5%. Losses shall be as per ECBC 2017. The transformer shall also have suitable enclosure including supply and fixing of neutral CT of suitable rating 5P10 on earthed star point with connector for connection to Earth Fault relay in HT/LT LT Chamber Suitable for terminating LT XLPE cables

1

-

-

... More
od210259/2019_2020 : HT Meteing Kiosk with Meteing Supply, installation, testing and commissioning of TOD meter KIOSK with Bidirectional TOD meter (with RS485 communication facility), test terminal block, control fuses,armoured copper cable between CTPT unit. The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 65 with canopy, weather proof,undergone seven tank process,powder coated finish ,earthing,entire civil work including suitable foundation and all mounting accessories as required complete as per the rquirement of State Electricity Board

1

-

-

... More
od210260/2019_2020 : Supply, Installation testing and commissioning of 11 KV DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x50mm and supporting structure for 11 KV components with 65x65x6 mm MS angle bracings between consumer and supplier structure,cross arms,11 KV pin,disc and stay insulators, supports, jumpering / interconnecting conductors with 0 SWG Cu, anticlimbig arrangement using barbed wire,earthing etc. on a suitable concrete foundation including the civil foundation .The DP structure shall consists of the following (Note:All the MS items shall be hot dip galvanised) 11 KV,400A ,TP,AB switch - 1 No 11 KV Lighting Arrestor -1 set of 3 Nos 11 KV DO fuses-1 set of 3 Nos CTPT unit with 3 Nos Resin Cast Current Transformers (**/5A class 0.2S) and 1 No PT(11kV/110V 0.2class) installed in a suitable container filled with transformer oil and as per KSEBL Specifications

1

-

-

... More
DG SET AND UPS WITH ACCESSORIES

-

-

-

... More
od210295/2019_2020 : 500 KVA DG SET Supply, Installation, Testing and Commissioning of 500 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable ACB etc. , including antivibration mountings, water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 500 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS 2613 & IS: 4722 The control panels shall have suitable protections like ACB with thermal O/L, Voltage controlled O/C relay, Over voltage, Undervoltage, Negative sequence, Low set EF relay and REF realay with fuel shutoff facilities. Overspeed protection shall also be provided Exhaust silencer and Class B MS exhaust piping of adequate size (withnecessary thermal insulation with aluminium cladding) between Generator and silencers and upto single header suitable for raising the exhaust system of 500kVA DG set with all necessary accessories as required complete as per the latest KSEI/KSEB/PCB norms. The steel for supporting the exhaust pipe is covered in this item Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards. Fuel tank for 8 hours suitable continous operation/ 990litres capacity whichever is lower, fuel piping from fuel tank to Engine, Residential silencer, LV chamber suitable for termination of busduct with extended Alternator terminal with bus bars etc as required and as per specifications.. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
od79838/2020_2021 : 30 kVA UPS- Supply, Installation , Testing and commissioning of a 30 kVA, three phase input, Three Phase output, true on-line UPS system with 15minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such breakers, cabling etc as required complete having following specification.The UPS system consist of UPS unit and battery bank . Fully digital controlled based on DSP PWM based on IGBT technology Power factor corrected from end 0.9 Pure sine wave output Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation, Remote Management Interphase,

2

-

-

... More
FIRE HYDRANT SYSTEM AND SPRINKLER SYSTEM Supply, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2280 lpm at 80m head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

2

-

-

... More
Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2280 lpm at 80m head conforming to IS 1520. (b) Suitable HP, 1500/1800 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,2x12/24V 180AH Batteries and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity 300 Litres) with level indicator, By-pass line,MS Piping to diesel tank from engine, exhaust pipe extended outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. (e) Diesel engine control panel.

1

-

-

... More
Supply, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification (a) Vertical inline, centrifugal type pump of stainless steel casing & stainless steel impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 80 m head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated base plate, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

2

-

-

... More
Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 150 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

10

-

-

... More
Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required as per technical specification.

5

-

-

... More
Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
Supply, laying, testing and commissioning of 'C' class heavy duty GI pipe conforming to IS 1239/IS 3589 including welding/joining, fittings like elbows, tees, flanges, tapers, GI nuts, bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps/ supports and painting with one coat of epoxy primer and two coats of synthetic enamel paint of required shade, complete as required as per technical specification. Welding shall not be permitted for pipes below 50mm.

-

-

-

... More
200 mm dia(6.35 mm thickness)

28

-

-

... More
150 mm dia

207

-

-

... More
100 mm dia

112

-

-

... More
80 mm dia

54

-

-

... More
65 mm dia

99

-

-

... More
50 mm dia

46

-

-

... More
40 mm dia

200

-

-

... More
32 mm dia

50

-

-

... More
25 mm dia

638

-

-

... More
Supply, laying, testing and commissioning of 'C' class heavy duty GI pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, GI nuts, bolts, gaskets etc. in ground at a depth of 1m including excavation & providing cement concrete blocks as supports, applying bituminous primer, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification.

-

-

-

... More
150 mm dia

208

-

-

... More
80 mm dia

6

-

-

... More
Supply, installation, testing and commissioning of dual plate non-return valve of following sizes having PN 16 rating conforming to API 594 complete with CI body, rubber gasket, GI bolts, nuts, washers etc. as required as per technical specification.

-

-

-

... More
150 mm dia

3

-

-

... More
100 mm dia

1

-

-

... More
65 mm dia

2

-

-

... More
Supply, installation, testing & commissioning of double flanged sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with GI nuts, bolts, washers, gaskets and conforming to IS 14846 of following sizes as required as per the technical specification.

-

-

-

... More
200 mm dia

2

-

-

... More
150 mm dia

3

-

-

... More
80 mm dia

2

-

-

... More
Supply, installation, testing and commissioning of butterfly valve having PN 16 rating conforming to IS 13095/API 609 complete with CI body, SS Disc, Nitrile Rubber/EPDM seal, O -ring, flanges, GI nuts, bolts, washers etc. as required as per technical specification.

-

-

-

... More
150 mm dia

8

-

-

... More
100 mm dia

10

-

-

... More
65 mm dia

2

-

-

... More
Supply, installation, testing and commissioning of lever operated full bore forged brass ball valve of following nominal diameter, minimum PN 16 rating, complete with bolts, washers, gaskets and accessories as required complete in all respect as per relevant standards & the technical specification. 40 mm dia

6

-

-

... More
Supply, installation, testing and commissioning of EPDM Rubber Flexible connectors (Expansion Bellows) of following sizes complete complete with GI nuts, bolts, gasket etc. as required as per technical specifications

-

-

-

... More
150 mm dia

6

-

-

... More
80 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
Supply,installation, testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain, GI nuts, bolts, gasket etc as per technical specification.

11

-

-

... More
Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. Pipe

7

-

-

... More
Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

22

-

-

... More
Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

11

-

-

... More
Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

11

-

-

... More
Supply, installation, testing and commissioning of Fire brigade collective breaching with 4 nos. of 150 mm flanged out let connection and built in check valves complete with GI nuts, bolts, gasket etc as required as per technical specification.

2

-

-

... More
Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification

3

-

-

... More
Supply, installation, testing and commissioning of Y strainer with CI body, 3 mm perforated SS screen, flanged end connection, of following size confirming to IS specifications complete with GI nuts, bolts, gaskets, seal and accssesories as required as per the technical specification.

-

-

-

... More
150 mm dia

3

-

-

... More
80 mm dia

2

-

-

... More
Providing, fixing, testing & commissioning of UL listed Standard response, standard coverage pendant type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. with rosette plate, complete as required as per the technical specification.

156

-

-

... More
Providing, fixing, testing & commissioning of UL listed Standard response, standard coverage upright type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. complete as required as per the technical specification.

244

-

-

... More
Providing, fixing, testing & commissioning of UL listed Standard response, standard coverage sprinkler, pendant type concealed sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. with cover plate, complete as required as per the technical specification.

8

-

-

... More
Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 15Kg/cm2 and operating pressure ranging from 3.5kg/cm2 to 10Kg/cm2. complete with all accessories as required as per the technical specification.

6

-

-

... More
Supply, installation, testing and commissioning of 1m unbraided flexible drop to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible drop with nipple, reducer, square bar and brackets etc as required as per technical specification.

149

-

-

... More
Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification.

1

-

-

... More
PORTABLE FIRE EXTINGUISHERS Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2006 with ISI mark.

24

-

-

... More
Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification.

6

-

-

... More
Supply, installation, testing and commissioning of Modular(Cealing mounted) ABC type extinguisher of 5Kg complete as required as per technical specification.

19

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke & heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be UL listed & FM Approved.

205

-

-

... More
Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be UL listed & FM Approved.

15

-

-

... More
Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be UL listed & FM Approved.

15

-

-

... More
Supply, installation, testing and commissioning of 5A 24V Power supply unit for hooters complete in all respect and as required as per technical specification.

3

-

-

... More
Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be UL listed & FM Approved.

17

-

-

... More
Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

15

-

-

... More
Supply, installation, testing and commissioning of wall mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

21

-

-

... More
Supply, installation, testing and commissioning of public address and talk back system consisting of 8 zone public address cum talkback console with mike and selector, multiple channel talk back facility with LCD display,power supply, battery charger, battery housing, suitable watt PA & mic, multiple channel selector with all call and mic on. The console shall be provided with suitbale capacity amplifier, amplifier rack if required (min 350W) and suitable capacity battery (min 12V) with built in battery charger, etc. complete as required for meeting the technical specifications and for operation of the system.

1

-

-

... More
Supply, installation, testing and commissioning of UL listed & FM approved microprocessor based 4 looped, intelligent addressable main fire alarm panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to integrate with analog/digital voice evacuation system (PA-talkback system) and shall be complete with all necessary accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers

1

-

-

... More
Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring purpose and send the signal from a flow switch to the alarm panel for initiating alarm when flow occur, as per the technical specification. The product shall be UL listed & FM Approved.

6

-

-

... More
Supply, installation, testing and commissioning of addressable control to automatically trigger on/off devices like jet fans, AHU, extract air fans etc in case of fire. The product must meet technical specification.The product shall be UL listed & FM Approved.

12

-

-

... More
Supply and laying of 2x 1.5sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground, on wall surface or recess as required as per the technical specifications.

6292

-

-

... More
Supply and laying of 25mm dia PVC conduit along with accessories like PVC bends, couplers, junction box, fastners, iron staples/ saddles/ screws, in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit etc. and complete as required as per the technical specification.

106

-

-

... More
Supply, installation, testing and commissioning of CO2/clean agent Linear heat detection using trace tube for flooding of electrical panels (main distribution MV panel) consisting of gas cylinders with weight calculated on the basis of volume of single largest compartment within the panel, UL listed trace tube of required design length, with a required capacity cylinder (One number), also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessories of complete functionality of system, complete as required as per the technical specification.

2

-

-

... More
SIGNAGE

-

-

-

... More
Supply and installation of photoluminescent glow signage such as Fire Duct/Fire Lift/Staircase/Fire Station/Hosereel signboard etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite, panel conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

24

-

-

... More
Supply and installation of photoluminescent glow signage of FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

2

-

-

... More
Supply and installation of photoluminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification

12

-

-

... More
Supply and installation of photoluminescent glow signage such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

24

-

-

... More
Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

12

-

-

... More
ELECTRICAL ITEMS Main Fire Pump Panel Supply, Installation, Testing and Commissioning of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised construction, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with bus bars extendable on both sides, including all the necessary internal wiring, suitable spreader etc. The panel shall be fabricated from a firm having CPRI certification with test certificates (required for short circuit rating, temperature rise test and IP classification) with following switchgears, metering instruments and accessories etc. complete in all respect as per drawing and technical specification. The panel shall be with top/bottom entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram. Incomer 320A FF SDU Busbar 320A TPN AL Busbar Instruments Voltmeter with VSS (0-500V) Acc. class 1 with 90 deg defl. Scale -1no, Ammeter (0-400A) Acc. class 1 with 90 deg defl. Scale-3 nos, 4A SP C curve MCB-3nos, RYB indication-1 set, CT 400/5A Cl1 -1set, Type1 SPD- 1 No Outgoing 125 A TPN SDU - 3 nos, 32 A TPN SDU - 3 Nos, 25 A DP MCB - 2 No Star-Delta starter suitable for 55 kW motor with ON/OFF push button and indicators with Auxiliary and power contactors-2 nos. Star-Delta starter suitable for 4 kW motor with ON/OFF push button with and indicators with Auxiliary and power contactors-2 nos. Space provision for fixing 3 phase star-delta starter with on/off push button, auxillary & power contactors & ON/OFF indication lamps,capacitors in spare outlets suitable for 55 kW motor - 1no. Space provision for fixing 3 phase star-delta starter with on/off push button, auxillary & power contactors & ON/OFF indication lamps,capacitors in spare outlets suitable for 4 kW motor - 1no. Auto Manual Selector Switch with Control wiring for Main & Jockey Pump. Annunciator with hooter accept / reset & control wiring. Above panel to be supplied with 2x12 V, 180 AH battery charger and control wiring to provide control power supply in case of power failure. Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification.

1

-

-

... More
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

-

-

-

... More
3C 95 sqmm Al

48

-

-

... More
3C 6 sqmm Cu

48

-

-

... More
2C 6 sqmm Cu

12

-

-

... More
Supplying and making end termination with brass double compression gland and aluminium/copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3C 95 sqmm Al

4

-

-

... More
3C 6 sqmm Cu

4

-

-

... More
2C 6 sqmm Cu

2

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Cable size upto 35sq mm

20

-

-

... More
Above 35 sq.mm upto 95 sq.mm

20

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Cable size upto 35sq mm

40

-

-

... More
Above 35 sq.mm upto 95 sq.mm

28

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
200 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.

-

-

-

... More
25mm x 5 mm GI

20

-

-

... More
3.15mm Cu (10 SWG)

40

-

-

... More
2 SWG Cu

40

-

-

... More
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

-

-

-

... More
25mm x 5 mm GI

40

-

-

... More
AIR COOLED DX UNITS Supply, installation, testing and commissioning (SITC) of the 5.5 TR or higher capacity air-cooled Ductable split air conditioner (IDU & ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 5 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,suitable dia CPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth as per specification along with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported. Equipment shall have vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications.

2

-

-

... More
AIR COOLED DX UNITS Supply, installation, testing and commissioning (SITC) of the 4TR TR or higher capacity air-cooled Ductable split air conditioner (IDU & ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 5 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,suitable dia CPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth as per specification along with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported. Equipment shall have vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications.

1

-

-

... More
AIR COOLED DX UNITS Supply, installation, testing and commissioning (SITC) of the 3 TR or higher capacity air-cooled Ductable split air conditioner (IDU & ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 5 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,suitable dia CPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth as per specification along with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported. Equipment shall have vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications.

1

-

-

... More
AIR COOLED DX UNITS Supply, installation, testing and commissioning (SITC) of the 2.5TR TR or higher capacity air-cooled Ductable split air conditioner (IDU & ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 5 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,suitable dia CPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth as per specification along with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported. Equipment shall have vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications.

1

-

-

... More
AIR COOLED DX UNITS Supply, installation, testing and commissioning (SITC) of the 1 TR or higher capacity air-cooled Ductable /Fan coil unit with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 5 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,suitable dia CPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth as per specification along with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported. Equipment shall have vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications.

1

-

-

... More
Supply, installation, testing and commissioning of suitable sized copper refrigerant piping(both suction and liquid piping) beyond 5 mtr including 19mm thick closed cell elastomeric Class 0 insulation finished with 7mils factory laminated glass cloth for 5.5 TR machine between indoor & outdoor units complete in all respects as per technical specifications.

15

-

-

... More
Supply, installation, testing and commissioning of suitable sized copper refrigerant piping(both suction and liquid piping) beyond 5 mtrincluding 19mm thick closed cell elastomeric Class 0 insulation finished with 7mils factory laminated glass cloth for 4 TR machine between indoor & outdoor units complete in all respects as per technical specifications.

5

-

-

... More
Supply, installation, testing and commissioning of suitable sized copper refrigerant piping(both suction and liquid piping) beyond 5 mtrincluding 19mm thick closed cell elastomeric Class 0 insulation finished with 7mils factory laminated glass cloth for 3 TR machine between indoor & outdoor units complete in all respects as per technical specifications.

8

-

-

... More
Supply, installation, testing and commissioning of suitable sized copper refrigerant piping(both suction and liquid piping) beyond 5 mtr including 19mm thick closed cell elastomeric Class 0 insulation finished with 7mils factory laminated glass cloth for 2.5 TR machine between indoor & outdoor units complete in all respects as per technical specifications.

4

-

-

... More
Supply, installation, testing and commissioning of suitable sized copper refrigerant piping(both suction and liquid piping) beyond 5 mtr including 19mm thick closed cell elastomeric Class 0 insulation finished with 7mils factory laminated glass cloth for 1 TR machine between indoor & outdoor units complete in all respects as per technical specifications.

5

-

-

... More
Supply , installation ,testing and commissioning of acoustically insulated Axial inline (upto 1000 CFM)/cabinet fans(Above 1000CFM) with suitable blower, impellers manufactured from galvanised steel . 1Phase/3 phase direct driven motor of following capacity for exhaust, with starter/starter panel , required lengths of power and control wiring, clamping, earthing other accessories etc., complete in all respects as per technical specifications.

-

-

-

... More
200 CFM with External static pressure 10 MM of WG

4

-

-

... More
700 CFM with External static pressure 15 MM of WG

1

-

-

... More
1500 CFM with External static pressure 20 MM of WG

2

-

-

... More
Supply, installation, testing and commissioning of suitable dia CPVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth along with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported etc. complete in all respects as per the technical specifications.

100

-

-

... More
AIR DISTRIBUTION Supply, Installation, testing and commissioning of factory fabricated machine made GSS sheet metal ducting complete with neoprene gaskets, elbows, splitter dampers, vanes, hangers, supports etc. for Supply air, Return air, Exhaust Air, Fresh Air as per ducting specifications and with suitable supports using MS angles, channels, rods, anchor bolts, etc. to roof /truss as per IS 655 / SMACNA standards complete in all respects as per the technical specifications.

-

-

-

... More
0.63 mm (24 Gauge)

235

-

-

... More
0.80 mm (22 Gauge)

55

-

-

... More
1.00 mm (20 Gauge)

10

-

-

... More
1.25 mm (18 Gauge)

5

-

-

... More
THERMAL INSULATION Supply, Installation, testing and commissioning of 19 mm thick, 40-60kg/m3 density, regular closed cell class 0 nitrile rubber insulation finished with 7 mils factory laminated glass cloth ,with anti-microbial protection. Butt all joints tightly and seal all breaks and joints by adhering glass cloth tape,fixing of insulation using OEM recommended fixing details ,supports and adhesive, tapes etc. complete in all respects as required by the technical specifications

229

-

-

... More
ACOUSTIC INSULATION Supply, Installation, testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1 with antimicrobial properties. ,having density of 140 kg/m3 ,fixing of insulation using OEM recommended fixing details ,supports and adhesive, tapes etc. and with fire resistance meeting as per BS 476 Part 6 & 7 and meeting NRC of 0.4 as per ISO 356 and . complete in all respects as per the technical specifications.

80

-

-

... More
AIR TERMINAL DEVICES Supply, Installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers . complete in all respects as per the technical specifications.

1

-

-

... More
Supply, Installation, testing and commissioning powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in all respects as per the technical specifications.

1

-

-

... More
Supply, Installation, testing and commissioning of Supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. complete in all respects as per the technical specifications.

3

-

-

... More
Supply, Installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core . complete in all respects as per the technical specifications.

3.5

-

-

... More
Supply, Installation, testing and commissioning of Aluminium extruded exhaust air louvers with damper, bird screen etc. . complete in all respects as per the technical specifications.

2

-

-

... More
Supply, Installation , testing and commissioning of Aluminium extruded fresh air louvers with fresh air damper, bird screen etc.. complete in all respects as per the technical specifications.

1

-

-

... More
Supply, Installation, testing and commissioning of opposed blade type Extruded Aluminium volume control dampers of 16 gauge GI sheets to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distributions system . complete in all respects as per the technical specifications.

5.5

-

-

... More
Fire dampers Supply, Installation, testing and commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for Air Distribution Networks. complete in all respects as per the technical specifications.

3.5

-

-

... More
Design, fabrication, supply ,Installation , testing and Commissioning of electric traction type with machine room type , Stainless steel 20(1360Kg) Pax Hospital elevator (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc.) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories complete with all accessories including Automatic Rescue Device (with dry maintenance free sealed batteries) in the event of power failure ,braille buttons,audio announcement along with prerecorded message as approved by Engineer-in-Charge complete as per technical specification. Having automatic centre/side opening SS door, stainless steel car enclosure provided with stainless steel handrails on two sides as applicable in accordance of following details:-6 stops & 6 openings and entrance & exit at same side and suitable for travel height of 18.6 mtrs. (Shaft Size 2200mm (width) x 3000mm (depth) ) with door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply provided in last landing near the elevator door.All fabrication and procedures shall confirm to relevant IS standards. The Equipment shall be complete in all respects as per technical specifications

1

-

-

... More
Design, fabrication, supply ,Installation , testing and Commissioning of electric traction type with machine room type 15 Pax(1020 Kg) Hospital elevator (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc.) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,brailiy buttons,audio announcement along with prerecorded message as approved by Engineer-in-Charge.The traction motor of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening SS door, stainless steel car enclosure provided with stainless steel handrails on two sides as applicable in accordance of following details:-6 stops & 6 openings and ntrance & exit at same side and suitable for travel height of 18.6 mtrs. (Shaft Size 1800mm (width) x 3000mm (depth) ) with door opening of 800mm (width) and 2100 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply provided in last landing near the elevator door.All fabrication and procedures shall confirm to relevant IS standards. The Equipment shall be complete in all respects as per technical specifications.

1

-

-

... More
Design , Engineering, Supply, Installation, Testing and Commissioning of MBBR based 40 KLD Sewage Treatment Plant including all mechanical, electrical, piping and instrumentation and associated all structurals for the Development of Taluk Hospital at Malayankeezhu as per tender technical specification. (Civil works shall be paid extra as per approved detailed BOQ and drawings)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.