KITCO Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date22 Apr 2025
Closing Date25 Apr 2025
Tender Amount₹ 51,57,499 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od307659/2022_2023 : Supply, Installation, testing, and commissioning of the following minimum capacity Double skin, sheet metal VRF compactable Ceiling Suspended Unit including AHU kit, all accessories as required as per technical specifications complete with outlet volume control dampers, canvas connections, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be a minimum 12watt/sq.ft. of coil surface area for equal distribution, The efficiency of the filters shall be 90% down to a particle size of 10 microns (MERV-8) and bag filter of 99.97% efficiency down to 0.3 microns (MERV 17-HEPA) filters complying to ASHRAE 52.2, cooling coil of copper tube and aluminum fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, power wiring and power/control cabling(indoor to outdoor), digital thermostat with required control wiring, required starter and starter panel, structural supports for fixing IDU, safety devices etc. the following minimum capacity and the cooling coil (min 4 rows), suitable for three-phase 440V supply, complete in all respects as per technical specifications.(Minimum External Static Pressure 25 mmwc )4 TR-1600 CFM - 25 mm of WG ESP

1

-

-

... More
od307665/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/4") 44.45 mm

10

-

-

... More
od307667/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 5/8") 41.275 mm

12

-

-

... More
od307669/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/2") 38.1 mm

10

-

-

... More
od307671/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8") 34.925

12

-

-

... More
od307672/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/4") 31.75 mm

10

-

-

... More
od307673/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8") 28.575 mm

10

-

-

... More
od307674/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 7/8") 22.22 mm

10

-

-

... More
od307675/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4") 19.05 mm

12

-

-

... More
od307676/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8") 15.875 mm

24

-

-

... More
od307677/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2") 12.7 mm

10

-

-

... More
od307678/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/8") 9.525 mm

36

-

-

... More
od307679/2022_2023 : Supply, Installation ,testing and commissioning of PDI Compatible central controller, along with associated accessories for controlling entire VRF system & 25% spare capacity for future provisions with suitable interconnecting control cabling between IDUs, ODUs and central controller ,Power wiring with necessary supports and complete in all respects as per the technical specifications.

1

-

-

... More
od307680/2022_2023 : Supply, installation, testing and commissioning of suitable dia PVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth along with required pipe fittings and accessories like Bends, Tees, reducers, clamps, suitably supported etc. complete in all respects as per the technical specifications.

50

-

-

... More
od307681/2022_2023 : Supply, Installation,Testing and Commissioning of minimum 2 TR Split air conditioning unit minimum capacity Invertor Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 3 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports, necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe (upto 5 m) 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulationfinished with 7 mils factory laminated treated fibre glass cloth, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, , first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete as required as per technical specification

2

-

-

... More
od307683/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.100 CFM -10 mm WG

3

-

-

... More
od307684/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.<be>400CFM-10mm ESP

2

-

-

... More
od307685/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 500CFM-10mm ESP

1

-

-

... More
od307686/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 600CFM-10mm ESP

1

-

-

... More
od307687/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 700CFM-10mm ESP

1

-

-

... More
od359492/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 1000 CFM -10 mm WG

1

-

-

... More
od308327/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 2250CFM -15mm of WG

1

-

-

... More
od308328/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 2500CFM -15mm of WG

1

-

-

... More
od308329/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 13000CFM -15mm of WG

2

-

-

... More
AIR DISTRIBUTION

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

335

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

390

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

15

-

-

... More
16.12.1.4 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

10

-

-

... More
od307647/2022_2023 : Supply, Installation, testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1 with antimicrobial properties. ,having density of 140-180 kg/m3 ,fixing of insulation using OEM recommended fixing details ,supports and adhesive, tapes etc. complete in all respects as per the technical specifications

51

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

538

-

-

... More
od307652/2022_2023 : Supply & fixing of Acoustic Insulation of AHU Rooms using open cell processed nitrile rubber having a density of 140-180 Kg/m3 and thickness of 25 mm with anti-microbial protection with suitable frame works etc. complete in all respects as required by the technical specifications

106

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

6

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

6

-

-

... More
od307660/2022_2023 : Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers ,bird screen etc. complete in all respects as per the technical specifications.

4

-

-

... More
od307664/2022_2023 : Supply, Installation , testing and commissioning of Aluminium Extruded Fresh air louvers with fresh air damper, bird screen etc complete in all respects as per the technical specifications.

2

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

4

-

-

... More
od307668/2022_2023 : Supply, Installation ,testing & commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks , complete in all respects as per the technical specifications.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.