KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Oct 2024
Closing Soon25 Nov 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Construction Of Taluk Head Quarters Hospital At Tirurangadi Malappuram

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

1104.05

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

1104.05

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

287.5

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

152.71

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

464.64

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

464.64

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m

1577.25

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

31.74

-

-

... More
od45092/2024_2025 : Disposal of earth/slush/building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping ground , beyond 50 m initial lead up to 5 km including all lifts involved as directed by the Engineer-in-charge

77.38

-

-

... More
od229949/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/rock.

74.52

-

-

... More
Concrete work

-

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1.33

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

137.28

-

-

... More
4.2.3 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1.88

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

32.99

-

-

... More
4.10 : Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).

49.62

-

-

... More
od326172/2021_2022 : Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course aftercleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

49.62

-

-

... More
4.17 : Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

90.54

-

-

... More
RCC work

-

-

-

... More
od230031/2020_2021 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.nothing extra shall be paid on this account)All work upto plinth level.

440.62

-

-

... More
od230032/2020_2021 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.nothing extra shall be paid on this account)All work above plinth level upto floor V level.

876

-

-

... More
od19743/2022_2023 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.nothing extra shall be paid on this account). All work upto plinth level

7.26

-

-

... More
od232550/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.(Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.nothing extra shall be paid on this account).All work above plinth level upto floor V level

8.42

-

-

... More
od300382/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 320 kg/ cum. (Note: - Minimum Cement content considered in this item is @ 320 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) .All work upto plinth level

26.78

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

6.24

-

-

... More
5.13 : Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span up to floor five level, including the cost of required centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

4.24

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

56508.56

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

131807.49

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

376.97

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1212.49

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

3365.12

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2811.4

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1940.23

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

120.56

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

505.78

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

172.38

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

2834.7

-

-

... More
5.28 : Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints.

677.52

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

426.4

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

65

-

-

... More
Masonry work

-

-

-

... More
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

6.06

-

-

... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

30.53

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

30.6

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

7.42

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

12.24

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete.

25.14

-

-

... More
od230155/2022_2023 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

44.02

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymermodified adhesive mortar all complete as per direction of Engineer-in-Charge. (Thepayment of RCC band and reinforcement shall be made for seperately).

514.19

-

-

... More
od230154/2022_2023 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half thick solid block masonry.

673.89

-

-

... More
od291776/2021_2022 : Extra for solid block/brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

19.13

-

-

... More
Joinery works

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

8117.84

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

2010.62

-

-

... More
od331815/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):toughened glass panes of 8 mm thickness

184.54

-

-

... More
od324784/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughened glass panes of 6 mm thickness

147.3

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

364.37

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

22.32

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

82.38

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

216

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

26

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

42

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

78

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

22

-

-

... More
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

1.9

-

-

... More
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop

45

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

22

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

269.6

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

68.16

-

-

... More
9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710

247.3

-

-

... More
9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

247.3

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

8

-

-

... More
od229394/2020_2021 : Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding window with necessary screws etc. complete.

119

-

-

... More
od229411/2020_2021 : Supplying And Fixing a pair of fire rated Solid SS Lever Handle and Mortise Lock case with Cylinder of approved size and quality for fire rated steel doors etc complete all works including all required fixtures as directed by Engineer in Charge.

18

-

-

... More
od229424/2020_2021 : Supplying And Fixing Glass to Glass Hook Lock of approved make WG-300G-G/G-PC45-NIDCSSS series or equivalent for Frameless glass double door with 60mm EPC - both side key , all complete as per approved drawings and as directed by Engineer in charge.

1

-

-

... More
od229428/2020_2021 : Providing and fixing a pair of back to back D type pull Handle of 25 mm Dia X 300 mm size ,mirror polished SS 304 grade with all fixtures and necessary ss screws etc.including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by the Engineer-in-Charge at all levels.

24

-

-

... More
10.27.1 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm

396

-

-

... More
10.27.3 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x120 mm

498

-

-

... More
od229429/2020_2021 : Providing and fixing hardwares for Handicaped door(Excluding door frame and panel).The shutter to be provided with cylindrical knob lock with rose diameter 75 mm and SS matt finished kick plate of dimension 300 MM X 1050 MM X 1MM including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing etc. complete as directed by the Engineer-in-Charge at all levels:

2

-

-

... More
od229970/2020_2021 : Provided and fixing dusted/frosted glass film of make 3M/Avery Dennison or equivalent of approved shade (overall thickness of Film + Adhesive shall be approx. 120 microns) on glass with customized prints with HP latex based high quality prints. The film shall install with self-adhesive and bubble-free installation to be done on clean glass .The rate shall include the cost and conveyance of all materials, labour charges, scaffolding, lead ,lift, sundries, print, wastage ,design, operations etc complete as directed by the Engineer in charge at all levels.

123.47

-

-

... More
od232110/2020_2021 : Providing and fixing of Wooden lead lined window with window frame shall be Single rebate profile made out of Hardwood (Red Mirandi) with 2 mm Lead Sheet sand witched in window frame. Frame shall be finished with primer finish .Window shall be fixed with 10 mm thick Lead Glass .Lead lined wooden fixed window of approved size 1.0 X 1.2 m or equivalent. The inside face of the frame face trim to rebate height shall be protected with minimum 2 mm thick lead line. Frames shall be provided with HRD Fasteners of approved Make or equivalent for installation on a finished plastered masonry/RCC wall opening. Installed frame shall be grouted with cement sand slurry necessary for window on the clear masonry opening. The rate shall includes the cost and conveyance of all materials , labour charges, lead,lift ,Lead glass of 10 mm thick and anchor fastener etc. complete as directed by the Engineer-in-Charge at all levels.

1.2

-

-

... More
od229971/2020_2021 : Providing and fixing of Galvanized hollow lead lined metal door conforming to IS 277 (2003) . Door frame shall be double rebate profile of size 143 x 57 mm (approx.) made out of approx. 2.0mm (14 gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height shall be protected with minimum 2 mm thick lead line. All provision shall be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers shall be provided on the strike jamb. Frames shall be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry/RCC wall opening.Installed frame shall be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be approx. 48mm thick fully flush double skin door and Door leaf shall be manufactured from approx 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door shall be rigid with lead line of minimum 2 mm thick all across the inside of the exposed surface. In addition the door shall have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges shall be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. All doors and frames shall be finished to powder coated for minimum 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Lead lined Steel Door Single leaf of size 1.2 X 2.40 m , the rate shall includes the cost and conveyance of all materials , labour charges,lead,lift, hardware like SS ball bearing hinges 100x75x3.0- 04 Nos.in each panel ,mortise dead lock with cylinder and both side key operation - 1 no , SS D type pull handle 300 X 20 mm - 1 set in each panel , heavy duty door closer- 1 no in each panel,Tower bolt 450 mm-1 no in each panel and anchor fastener etc. complete as directed by the Engineer-in-Charge at all levels.

2

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded)

139.2

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately.

50.34

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

1.98

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

15.48

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

4

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

0.81

-

-

... More
Steel works

-

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

3198.72

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

9814.66

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

10782.29

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

1552.22

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1721.7

-

-

... More
10.29.2 : Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides

62.07

-

-

... More
Flooring works

-

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1109.34

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

308.29

-

-

... More
11.46.3 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 800 x 800 mm

49.28

-

-

... More
od229795/2020_2021 : Providing and laying Anti-skid Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

110.98

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.

788.88

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

44.13

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick.

17.3

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement.

451.26

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

108.8

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

31.37

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

251.2

-

-

... More
8.4 : Extra for fixing marble/ granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.

61.56

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

17

-

-

... More
8.9.1.2 : Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade

21.12

-

-

... More
16.89 : Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

61.16

-

-

... More
11.45 : Providing and laying 500x500x40 mm thick Turf paver (Turfpaver XD) on 150 mmthick sub grade of compacted bed of 20 mm thick nominal size stone aggregateand base course and filling with 150 mm thick jamuna sand, including spreading,well ramming, consolidating and finishing smooth etc. all complete as per directionof Engineer-in-charge.

135

-

-

... More
od130499/2021_2022 : Providing and fixing, Highly resistant 2 mm thick pressed homogeneous vinyl floor covering in rolls including skirting (T Group), with non-directional design, colour dyed as a raw mixture to ensure even colour throughout the thickness and a matt finish including self-levelling upto 3mm thick with cementitious material . Its surface is densely compacted for improved wear and ease of maintenance. It is suitable for very heavy traffic. It is treated with Evercare surface treatment, the latest improvement in polyurethane surface treatment obtained by UV laser cross linking process. Evercare avoids stain of chemical products used in healthcare like betadine, eosin or anti-bacterial hand gel which also increases the durability of the flooring that does not require wax for life. Do not require the application of any protective emulsion for life. Abrasion value according to EN 660-2,2.0 mm3, group T binder content type I, load resistance class 34/43, residual indentation 0.03mm. Fire classification Bfl-s1. After 28 days the TVOC 10g/m3 according to ISO 16000-6. REACH compliant. Floorscore certified. Weight 2750 g/m2. ISO717-2 Weighted improvement of impact sound insulation is 8db. Anti-Viral activity (human coronavirus 229E) ISO 21702,99.7% (after 2h00). It incorporates bacteriostatic and fungistatic actions, tested for Anti-bacterial activity (ISO 22196 ,99% inhibit the growth of bacteria)The rate is inclusive of cost of all materials, upto 3 mm thick self-levelling, welding all joints, skirting, coving, capping, labour, lead, lift etc. complete as directed by the Engineer-in- Charge at all levels

58.34

-

-

... More
Roofing works

-

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

97.15

-

-

... More
12.51.2 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Flashings / Aprons (Upto 600 mm)

52.4

-

-

... More
12.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)

14.5

-

-

... More
od43266/2024_2025 : Providing and fixing 4mm thick UV solid modular standing seem Poly carbonate sheet (Length: 6mtrs,Width: 0.6mtrs) as approved by Engineer-in-charge . The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface etc complete as per the direction of Engineer-in-charge. but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

61.5

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.

63.38

-

-

... More
12.53 : Providing and Fixing 15 mm densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone /cosmos /Hexa or equivalent of size 595x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main 'T' of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid, including cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main 'T' runners to be suspended from ceiling using G.I slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm, spaced at 1200mm centre to centre along main 'T' bottom exposed with 24 mm of all T- sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), light reflection 85% non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC.

514.06

-

-

... More
Finishing works

-

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

7685.43

-

-

... More
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

1101.96

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

27

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

3471.82

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

1609.26

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

6609.5

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

451.52

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

3461.41

-

-

... More
13.48A.1 : Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and includingpriming coat of exterior primer applied @ 0.90 litre/10 sqm.

6157.98

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

1524.62

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

224

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

195

-

-

... More
13.109.1 : Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat ofprimer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.

192

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

66.14

-

-

... More
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)

115.2

-

-

... More
Paving works

-

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

196.5

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

28.8

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

382

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

286.5

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern.

1910

-

-

... More
Waterproofing and miscellaneous works

-

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

363.56

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

82.47

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

580.13

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

434.26

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

197.06

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

41.1

-

-

... More
od140030/2023_2024 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

1

-

-

... More
16.3.3 : Supplying and stacking at site.53 mm to 22.4 mm size stone aggregate

0.72

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.72

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.72

-

-

... More
od228640/2022_2023 : Supplying and planting healthy plants of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of plants size 25 cm of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.

4

-

-

... More
od140029/2023_2024 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

9

-

-

... More
od229915/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
19.18.1 : Supplying and fixing C.I with out frame for manholes:455 x 610 mm rectangular C.I cover ( light duty ) the weight of the cover to be no less than 23 kg

1

-

-

... More
19.18.2 : Supplying and fixing C.I with out frame for manholes:500 mm diameter C.I. (medium duty) the weight of the cover to be not less than 58 kg

10

-

-

... More
21.7.2 : Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Powder coated aluminium sheet 2.5 mm thick ( minimum thickness of powder coating 50 micron)

161.84

-

-

... More
21.17 : Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).

358.75

-

-

... More
SANITARY INSTALLATIONS AND FIXTURES

-

-

-

... More
od254187/2020_2021 : Providing and fixing white vitreous china extended wall mounting water closet of approved shape and size including providing , fixing white vitreous china cistern with dual flush fitting, of flushing capacity 2 litre/4 litres , including seat cover, and cistern fittings, nuts, bolts, CP brass angle valve and gasket etc complete as directed by the Engineer in charge at all levels. Models Cera S1031111+B1020105+B1520102/ Hindware 20096 (P-15)+Cist.: 21056 or equivalent with griha water conservation mechanism etc complete as directed by the Engineer in charge at all levels.

11

-

-

... More
17.1.2 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:Stainless Steel AISI-304 (18/8) orissa pattern W.C. pan of size 585x 480 with flush pipe and integrated type foot rests

3

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

16

-

-

... More
od254190/2020_2021 : Providing and fixing white vitreous china wall hung wash basin of approved make including one CP brass pillar cock with water conservation mechanism including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling,angle valve etc ,complete including CI/MS brackets duly painted, nuts, washers, etc. complete,cost and conveyance of all materials labour charges ,lead, lift necessary wall cutting / chasing and making good the walls, floors, slab,testing and commissioning to the satisfaction of Engineer in charge at all levels. Models Cera S2040105/Hindware 10054+Cera F1015101/Hindware F280001CP or equivalent as instructed by the Engineer in charge

5

-

-

... More
od254208/2020_2021 : Providing and fixing star white vitreous china under counter wash basin of approved size , make including one CP brass pillar cock 15 mm NB with aerator including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap, 15mm angle valve, etc. complete as directed by the Engineer-incharge at all levels.(Models Cera S2030103/ Hindware 10049+ Cera F1015101/Hindware F280001CP or equivalent with griha water conservation arrangement as per the instructions of the engineer in charge)

15

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

23

-

-

... More
od254451/2020_2021 : Providing and fixing white vitreous china flat back urinal with sensor and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Models Hindware 6002110 / Cera S4010101 or equivalent with griha water conservation mechanism etc complete as directed by the Engineer in charge at all levels.

8

-

-

... More
od252505/2020_2021 : Supplying and fixing approved quality white vitreous china urinal division plate including cost and conveyance of all material, labour charge, lead, lift, etc. complete as directed by the Engineer-in-Charge. Models- Cera S4090101/ Hindware 61001 or equivalent.

8

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

7

-

-

... More
od254454/2020_2021 : Providing and fixing sink cock of approved quality conforming to IS 8931. Models Cera F1015251/Hindware F330034 or equivalent with griha water conservation mechanism as approved by the engineer in charge at all levels

7

-

-

... More
od254042/2020_2021 : Providing and fixing Stainless Steel A ISI 304 (18/8) 2 station Scrub sink with elbow oberated sink cocks as per IS 13983 with C.I. brackets and stainless steel plugs 40 mm, including painting of fittings and brackets, cutting and making good the walls etc complete as per the requirements of the site in charge including cost of conveyance, testing, commissioning, installation etc.

1

-

-

... More
od254276/2020_2021 : Providing and fixing Stainless Steel A ISI 304 (18/8) bed pan sink of approved shape and size with elbow operated sink cock as per IS 13983 with C.I. brackets and stainless steel plugs 40 mm, including painting of fittings and brackets, cutting and making good the walls etc complete as per the requirements of the site in charge including cost of conveyance, testing, commissioning, installation etc as directed by the Engineer in charge at all levels.

2

-

-

... More
od254243/2020_2021 : Providing and fixing C.P. brass long body bib cock with griha water conservation mechansim of approved quality conforming to IS standards and weighing not less than 690 gms. Models Hindware F400002CP/ Jaquar FLR-CHR-5047NGE or equivalent 15 mm nominal bore

18

-

-

... More
18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore

8

-

-

... More
od252519/2020_2021 : Providing and fixing CP Brass robe hook as per the instructions of the Engineer in charge. Models Cera F5003108/ Hindware F880004CP or equivalent

16

-

-

... More
od254109/2020_2021 : Providing and fixing sanitary fixtures for handicapped toilet including one wash basin , one number pillar cock with aerator , all other related fittings like CP brass bottle trap,CP brass angle valve, CP brass waste coupling, etc, one number EWC , Cistern complete with fittings , seat cover, one no. hinged rail , 4 nos. of grab rails 60cm etc, designed for people with special needs comes with as per manufacturers specification including cutting and making good the walls and floors wherever required as directed by Engineer-in-Charge. Hindware Matrix Set/Cera Cruse Set, Hindware F280001CP/ Cera F1015101 or equivalent.

2

-

-

... More
od254274/2020_2021 : Providing and fixing premium quality C.P. brass wall shower mixer with griha water conservation mechanism along with overhead shower and shower arm with wall flanges of approved make and model including cost of all materials, labour etc., complete as directed by the Engineer-in-Charge at all levels. Models Cera F7040104+F1015401+F7020304/ Jaquar OHS-CHR- 1989GD+FLR-CHR-5273UPRGD or equivalent .

2

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

2

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

2

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

22

-

-

... More
od254457/2020_2021 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels

3

-

-

... More
od254458/2020_2021 : Providing and fixing floor trap 110 mm dia (gratings exposed)with cockroach trap (multi trap), S304 grade exposed floor grating with multitrap including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

28

-

-

... More
od252540/2020_2021 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame , Round Frame with Flat Round Cover with Rubber Seal , SS Screw including cost and conveyance of all materials, labour charges, sundries, etc complete as directed by the Engineer in charge at all levels. 75mm dia

1

-

-

... More
od252543/2020_2021 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame , Round Frame with Flat Round Cover with Rubber Seal , SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels. 110mm dia

6

-

-

... More
od254449/2020_2021 : Supply, Installation, Testing and Commissioning of Solar Water Heater 1000 LPD with heater backup with all necessary accessories as per the requirements of the Engineer in charge at all levels.The rate is inclusive of cost and conveyance of all materials, labour charges etcpply, Installation, Testing and Commissioning of Solar Water Heater 1000 LPD with heater backup with all necessary accessories as per the requirements of the Engineer in charge at all levels. The rate is inclusive of cost and conveyance of all materials, labour charges etc

1

-

-

... More
WATER SUPPLY ARRANGEMENTS

-

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

40

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

40

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

20

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

53

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

100

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

172

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

26

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

20

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

35

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

58

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

18

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

71

-

-

... More
od252506/2020_2021 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot , cold water supply, including all CPVC plain , brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes , fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 62.5 inner dia pipes

27

-

-

... More
od120026/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot , cold water supply, including all CPVC plain , brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes , fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 75 mm nominal inner dia Pipes

3

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

66

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

14

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

1

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

3

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

11

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

5

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

4

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

8

-

-

... More
od252547/2020_2021 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm dia

15

-

-

... More
SANITARY ARRANGEMENT

-

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

6

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

7

-

-

... More
od252515/2020_2021 : Supplying, fixing, testing and commissioning to the satisfaction of Engineer in charge of PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and water tight C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge

7

-

-

... More
od252518/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings , specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - Internal work- Exposed on wall

136

-

-

... More
od252520/2020_2021 : Supplying and fixing GI threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.

77

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

198

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

121

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

12

-

-

... More
50.18.7.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

18

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

41

-

-

... More
od252532/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings , specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

7

-

-

... More
od252535/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings , specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

280

-

-

... More
od252538/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings , specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 kgf/cm2

43

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

43

-

-

... More
od252541/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings , specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110mm pipe 6 kgf/cm2

50

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

50

-

-

... More
PUMPS, FILTERS AND ACCESSORIES

-

-

-

... More
od252501/2020_2021 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller,mechanical seal, complete with motor which shall be IE3 rated as per IS 12615 and pump efficiency meeting ECBC standards, including base plate, foundation bolts, nuts,pressure gauge and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels Capacity 250-110 lpm , Head - 24-36m

6

-

-

... More
od256537/2020_2021 : Supplying ,fixing, testing and commissioning of portable drainage pump , with stainless steel construction, stainless steel impeller complete with motor which shall be IE3 as per IS 12615 and pump efficiency meeting ECBC standards , with all accessories and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all labour charges,lead,lift etc as directed by the Engineer in charge at all levels

1

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal bore Horizontal

6

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal bore Horizontal

2

-

-

... More
od252507/2020_2021 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mm

6

-

-

... More
od252510/2020_2021 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm Y type strainer

6

-

-

... More
od252512/2020_2021 : Supplying and installing activated carbon filter of size 5 cum/hr with internally and externally epoxy coated, raw water distributor, filter water collecting system, pressure gauges at inlet and outlet, strainers, supporting structure, back wash arrangement, set of inlet and outlet valves, V-notch Board etc and all other accessories .The rate shall include cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

1

-

-

... More
od252514/2020_2021 : Supply and erection of dual media filter of size 0.6m dia x 1.2 m HOS, (approx.) vertical type pressure vessel, mild steel internally and externally epoxy coated, 6mm shell thickness, 6mm dish thickness, flanged top and bottom, operating pressure of 3.5 Kg/cm2, complete with CI valves and graded pebble and sand as media, frontal piping, pressure gauges, strainers, supporting structure, back wash arrangement, etc and all other accessories .Flow rate 5m3/hr

1

-

-

... More
od252516/2020_2021 : Supplying and fixing of electronic diaphragm type dosing pump suitable for pumping chlorine solution including cost of valve, suction and delivery lines using heavy duty PVC tubes, HDPE chlorine feed tank of 100 litres capacity etc. and complete with all accessories as directed by the Engineerin -Charge. Capacity : 6 lph @ 3.5 kg/cm2

1

-

-

... More
od252530/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

4

-

-

... More
od252533/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mm

1

-

-

... More
od252536/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mm

8

-

-

... More
od252539/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mm

1

-

-

... More
od252542/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 80mm

2

-

-

... More
od252544/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 80mm

5

-

-

... More
od252548/2020_2021 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm

12

-

-

... More
od252549/2020_2021 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm

2

-

-

... More
od254462/2020_2021 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 300 mm dia R.C.C. pipe

11

-

-

... More
od254463/2020_2021 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 150 mm dia R.C.C. pipe

11

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

22

-

-

... More
DG AND ACCESSORIES

-

-

-

... More
od159755/2023_2024 : DG Set - 160kVA 160 KVA DG SET, Supply, Installation, Testing and Commissioning of 160 kVA prime rated D.G Set with acoustic enclosure and Control panel including reverse power relay, protection and digital metering, controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including anti vibration mountings, and other accessories conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 160 kVA prime rating, brushless, self-excited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 , IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank suitable for continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. The work should be as per Electrical Inspectorate/ Central Pollution control board(CPCB IV) standards applicable at the time of delivery.

1

-

-

... More
od25804/2024_2025 : EXHAUST PIPES;Supplying and fixing the following size exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool 50 mm thick wire mesh , 0.63mm aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 9m radius of the exhaust. Sizing shall be based on the backpressure calculation furnished by the OEM and shall be approved by EIC. 4 inch dia exhaust pipe.

18

-

-

... More
LT PANEL BOARDS & ACCESSORIES

-

-

-

... More
od254281/2023_2024 : Supply, Installation, Testing and Commissioning of 15 kVA, Three phase input, Three Phase output, High Performance IGBT/PWM based True-On-Line Double Conversion UPS system with Isolation transformer and 15 minutes back up including SMF batteries VRLA type with powder coated CRCA cabinet including all accessories and cabling etc as required complete having following specification. The UPS system consist of one numbers of UPS unit and one set of battery bank , Fully digital controlled based on DSP, Power factor corrected from end > 0.95 ,Input THDi<3%, Pure sine wave output. ECO Mode for efficiency up to 98%,Full time output voltage , frequency regulation, Auto regulation of battery end voltage Intelligent interface with LED/LCD display, Static bypass switch, manual by pass switch Auto temperature compensation, Remote Management Interphase, testing as per various load conditions shall be done at site to establish the supplied item is complying the specifications.

1

-

-

... More
od258828/2023_2024 : 1.FIRE PANEL - Supply, Installation, Testing , Commissioning of 415V, 50Hz, LT switch board conforming to IEC 61439 Part 1, 2 ( for panel fabrication) fabricated from ASTA/ASEFA/DECRA/KEMA/LOVAG/UL/CPRI/ERDA certified vendors. The enclosure shall be 2mm thick CRCA sheet , which shall be free standing with floor mounting base with suitable mounting brackets with following switchgears, metering instruments and accessories etc. complete as required as per drawing specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3b or above. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker. The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with approriatly rated HRC fuses. The battery charger and all its components should be housed inside the control panel. The panel shall be painted with approved colour. The panel shall be suitable for TOP/BOTTOM Cable ENTRY. Incomer- 160A, 4 Pole Mccb isolator Instruments and meters: 4 A HRC Fuse with base, Ammeters, Voltmeters, Selector Switches, Multifunction Meters Indication Lamps, CTs, IPFC Relay as per SLD. Busbar :160A TPN busbar chamber with Aluminium busbar. Outgoing - (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps). Main Fire Pump - 125A, TP MCCB ISOLATOR, with fully automatic Star/Delta starter suitable for 45kW pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump - 40 A TP MCCB Isolator with fully automatic DOL starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 25A DP MCB- 1No DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch , 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification.

1

-

-

... More
od258829/2023_2024 : SB Supply, Installation, Testing , Commissioning of fully type tested design verified 415V, 50Hz, LT switchboard conforming to IEC 61439 Part 1, 2 fabricated from ASTA/ ASEFA/ DECRA/ UL/ KEMA/ LOVAG certified vendors and who shall be authorized panel fabricators of approved makes of OEMs. The type, size and manufacturing of enclosure shall be same as is for the design verified panel. The panel shall be free standing with floor mounting base and required base frame, mounting bracket etc shall be supplied and panel shall be with following switchgears, metering instruments and accessories etc. as per drawing , specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3b or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports ,temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry INCOMER 1 160A,FP 25kA MCCB with thermal based adjustable release with OL , SC protection - 1 Nos Instruments 4A, C curve SP MCB -1 sets RYB indication lamp, LED type - 1 sets Digital multifunction meter with RS 485 Comunication Facility-1 nos ON/OFF/TRIP indication lamp, LED type - 1 set Busbar 200A TPN busbar chamber with Aluminium busbar Out goings 63A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL , SC protection - 4 No 40A, TP+NL,25kA, MCCB with Thermal Magnetic based release with OL , SC protection - 4 No

1

-

-

... More
od258830/2023_2024 : MSB Supply, Installation, Testing , Commissioning of fully type tested design verified 415V, 50Hz, LT switchboard conforming to IEC 61439 Part 1, 2 fabricated from ASTA/ ASEFA/DECRA/ UL/ KEMA/ LOVAG certified vendors and who shall be authorized panel fabricators of approved makes of OEMs. The type, size and manufacturing of enclosure shall be same as is for the design verified panel. The panel shall be free standing with floor mounting base and required base frame, mounting bracket etc shall be supplied and panel shall be with following switchgears, metering instruments and accessories etc. as per drawing , specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3b or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports ,temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry INCOMER 1 , 2 250A,FP 25kA MCCB with thermal based adjustable release with OL , SC protection - 2 Nos 250A FP ATS with AMF Facility- 1No Instruments 4A, C curve SP MCB -2 sets RYB indication lamp, LED type - 2 sets Digital multifunction meter with RS 485 Comunication Facility-1 nos ON/OFF/TRIP indication lamp, LED type – 2 set (As per SLD) Busbar 300A TPN busbar chamber with Aluminium busbar. Surge Protection Device: SPD type-1+2 Out goings 160A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL , SC protection - 2 No 100A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL , SC protection -1 Nos 80A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL , SC protection -1 Nos 63A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL , SC protection - 2 Nos 40A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL , SC protection - 2 Nos 160A FP MCCB TPN MCCB Isolator - 1 No

1

-

-

... More
LT CABLES AND CABLING

-

-

-

... More
9.1.12 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)

4

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

4

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

6

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

12

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

90

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

240

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

40

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

20

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

70

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

343

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

56

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

20

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

667

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

16

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

112

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

9

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

20

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

20

-

-

... More
14.16.1 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)

20

-

-

... More
14.16.2 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)

50

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
4.6.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness

50

-

-

... More
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.7.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
4.8.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.8.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.8.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
4.9.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
4.9.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
4.9.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.10.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.10.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.10.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
od250679/2023_2024 : Supply of 4C 16 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

107

-

-

... More
od250681/2023_2024 : Supply of 3.5C 150 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

480

-

-

... More
od250682/2023_2024 : Supply of 3.5C 185 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

138

-

-

... More
od250747/2023_2024 : Supply of 3C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

132

-

-

... More
od250748/2023_2024 : Supply of 3C 70 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

48

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

14

-

-

... More
od251676/2023_2024 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 25 Sq.mm AL

210

-

-

... More
od251730/2023_2024 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed cable of 1.1 kV grade as required. 4C 2.5 Sq.mm 1.1 KV grade Cu. Conductor

26

-

-

... More
od251733/2023_2024 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed cable of 1.1 kV grade as required. 3C 4 Sq.mm 1.1 KV grade Cu. Conductor

18

-

-

... More
7.4.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 95 sq. mm and upto 185 sq. mm

176

-

-

... More
od255037/2023_2024 : Supply of 3.5C 50 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Al conductor cable conforming to IS 7098 (Part 1) amended upto da

24

-

-

... More
od255038/2023_2024 : Supply of following 4C 2.5Sq.mm Cu size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

189

-

-

... More
od263645/2023_2024 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of zinc chromate primer and two coats of enamel paint of approved make.

200

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

10

-

-

... More
od23746/2024_2025 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 10 Sq.mm AL

66

-

-

... More
od23747/2024_2025 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 10 Sq.mm AL

456

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

46

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1500

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

30

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

233

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

11

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

10

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

13

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

2

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

30

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

87

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

75

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

2

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

221

-

-

... More
od175261/2023_2024 : Supply , fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

24

-

-

... More
od175291/2023_2024 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

42

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

1200

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

600

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

500

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

16

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

16

-

-

... More
MCB's AND DISTRIBUTION BOARD's

-

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

174

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

42

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

30

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

4

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

4

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

5

-

-

... More
90.14.28.2 : S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor

8

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

9

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

4

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od175297/2023_2024 : Supply, Installation, Testing , Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

1

-

-

... More
od175300/2023_2024 : Supply, Installation, Testing , Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

5

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

4

-

-

... More
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od251103/2023_2024 : Supply and installation of sheet steel, phosphatized and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 12 way (8+36) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od251734/2023_2024 : Providing and fixing following rating and breaking capacity MCCB with thermal magnetic release in existing DB including all accessories as required. 80A,25kA FP MCCB

1

-

-

... More
od252188/2023_2024 : Supply and fixing of following 40-63A FP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required

7

-

-

... More
od252195/2023_2024 : Supplying and fixing following rating,63 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

-

... More
od252196/2023_2024 : Supplying and fixing following rating, 25 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

4

-

-

... More
od252197/2023_2024 : Supplying and fixing following rating, 40 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

3

-

-

... More
od252311/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.6A to 32A ,SP D CURVE

42

-

-

... More
od252293/2023_2024 : Supply and fixing of 6-32A FP MCB, C-Curve following rating, 10 KA, Miniature Circuit Breakers as required

9

-

-

... More
od255108/2023_2024 : Supply and fixing of 40-63A TP MCB, C-Curve following rating, 10 KA, Miniature Circuit Breakers as required.

2

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

11

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

257

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

328

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

20

-

-

... More
od161033/2023_2024 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

51

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

17

-

-

... More
od162740/2023_2024 : Supply of 20W Surface/Suspended Mounted LED Batten of maximum wattage below 20W with System efficacy of more than 120 lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 4 KV internal surge protection. Power factor greater than 0.95 ,CCT 5700K+-/300K,ripple factor<5 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire and EMI/EMC compatible

74

-

-

... More
od163396/2023_2024 : Supply of 40W Surface/Suspended Mounted LED Batten of maximum wattage below 40W with System efficacy of more than 120 lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 4 KV internal surge protection. Power factor greater than 0.95 ,CCT 5700K+-/300K,ripple factor<5 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire and EMI/EMC compatible

35

-

-

... More
od177002/2023_2024 : Supply of 40W (+/-2) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing , High Efficiency Translucence (HET) diffuser.System efficacy > 100 lm/W, pf > 0.95, THD <10%, ripple factor <5, UGR <19, CRI>80, SDCM<5, life - 50000 hrs @L70, CCT 5700+300 K and EMI/EMC compatible, surge protection: at least 4 KV inbuilt with the electronic drive system.

6

-

-

... More
od177023/2023_2024 : Supply of 30W (+/-2) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing , High Efficiency Translucence (HET) diffuser ,System efficacy > 100 lm/W, pf > 0.95, THD <10%, ripple factor <5, UGR < 19,CRI>80, SDCM<5, life - 50000 hrs @L70, CCT 5700+300 K and EMI/EMC compatible, surge protection: at least 4 KV inbuilt with the electronic drive system.

6

-

-

... More
od177224/2023_2024 : Supply of 10W, High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. System efficacy >100 lm/w, pf > 0.95, THD <10 %, ripple factor <5, UGR <19, CRI>80, SDCM<5, life - 50000 hrs @L70, ccr 5700+300 K and EMI/EMC compatible, surge protection: at least 4 KV inbuilt with the electronic drive system.

4

-

-

... More
od177320/2023_2024 : Supply of 10W High efficient LED batten surface/wall mounted, maximum wattage below 10w Systemefficacy of more than 110 lm/W and lumen output of luminaire greater than 1000 lumen, designedextruded channel in thermally conductive material with plastic with HET diffuser. CRI >80,THD<10%, Powerfactor>0.95, CCT 5000 - 6000 K ,, ripple factor <5 and EMI/EMC compatible., 50000 burning hours as per L70 Criteria

26

-

-

... More
od177385/2023_2024 : Supply of 18W (+/-2), High efficient recess mounted LED round downlighter withwhite powder coated, Aluminium die cast aluminium housing. System efficacy >100 lm/w, pf > 0.95, THD <10 %, ripple factor <5, UGR <19, CRI>80, SDCM<5, life - 50000 hrs @L70, ccr 5700+300 K and EMI/EMC compatible, surge protection: at least 4 KV inbuilt with the electronic drive system.

77

-

-

... More
od177388/2023_2024 : Supply, installation, testing and commissioning of skirting light with all accessories as required complete

20

-

-

... More
od177830/2023_2024 : Supply of 18W (+/-2), High efficient surface mounted LED round downlighter withwhite powder coated, Aluminium die cast aluminium housing. System efficacy >100 lm/w, pf > 0.95, THD <10 %, ripple factor <5, UGR <19, CRI>80, SDCM<5, life - 50000 hrs @L70, ccr 5700+300 K and EMI/EMC compatible, surge protection: at least 4 KV inbuilt with the electronic drive system.

102

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

237

-

-

... More
od178248/2023_2024 : Supplying and fixing extra conduit down rod of G.I. pipe 15 mm dia, heavy gauge including painting etc. for ceiling fans as required

100

-

-

... More
od178249/2023_2024 : Supplying and fixing Metal conduit Pipe of more than 8 mm dia, including powder coating/Spray painting similar to the colour shade of the light fixture and all accessories in complete for suspending the light fixture as required.

120

-

-

... More
od178322/2023_2024 : Supply of 450 mm sweep,1400 rpm heavy duty exhaust fan with self opening louvers working on 230 V AC supply complete with all accessories as required.

1

-

-

... More
od178418/2023_2024 : Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required

97

-

-

... More
od178553/2023_2024 : Supply of indoor recess mounted 2'X2' LED luminaire with housing made of Metallic CRCA powder coated body or pressure die cast Aluminium body with a high efficiency diffuser along with suitable driver and surge protection, Maximum system wattage of 24 Watts, luminous efficacy greater than 110 lumen/watt and system lumen output more than 2400lm, pf > 0.95, THD <10%, ripple factor <5, UGR <19,CRI>80, SDCM<5, life - 50000 hrs @L70, ccr 5700+300 K and EMI/EMC compatible, surge protection: at least 4 KV inbuilt with the electronic drive system.

4

-

-

... More
od178761/2023_2024 : Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal body with self opening louvers working on 230 V AC supply complete with all accessories as required.

19

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

60

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

200

-

-

... More
od161155/2023_2024 : Supply and fixing anodised aluminum glass framed shock treatment chart.

1

-

-

... More
od161156/2023_2024 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size including lamination etc. as required complete on wall.

1

-

-

... More
od166069/2023_2024 : Supply , providing ISI plate earthing as per IS 3043 with 1200x1200x12.5mm GI / CI earth plate with 20mm dia B class GI pipe for watering, 50x6mm GI strip welded to the plate, GI funnel with weld mesh, fixing GI strip of size 50x6mm with min. length of 20cm clamped with 50x6mm GI flat using 12x10mm GI bolt , nut at top of the GI pipe as test joint, filling around the GI pipe at a radius of 15cm with a homogeneous mixture of charcoal, , river sand upto a height of 2.5 meter from the bottom, filling the rest of the portion with excavated soil including watering , ramming providing brick work (20cm) masonary at top in 1:6 cement mortar, plastering the inside , top of the manhole with 12mm thick 1:6 cement mortar and providing gully trap with 450x450x10mm CI covering at the top.

15

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

80

-

-

... More
od261734/2023_2024 : Supplying and laying 25mm X 3mm Cu strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt , spring washer spaced at 50mm)

110

-

-

... More
od261735/2023_2024 : Providing and fixing 25mm X 3mm Cu Cu strip on surface or in recess for connections etc. as required.

60

-

-

... More
od261870/2023_2024 : Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt , spring washer spaced at 50mm)

230

-

-

... More
od262173/2023_2024 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

30

-

-

... More
od262174/2023_2024 : Supply and fixing of First aid box

1

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

150

-

-

... More
od167742/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for Sheet roof with the required mounting clamps , cross connectors , expansionpiece and other accessories required as per IEC 62305-3

200

-

-

... More
od167743/2023_2024 : : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

150

-

-

... More
od262087/2023_2024 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip

6

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
od262388/2023_2024 : Replacing and fixing of 2 number of 5 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) in existing APFC panel board by 2 number of 20 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H), including drilling holes in cubicle panel, making connections, etc. as required.

1

-

-

... More
od262389/2023_2024 : Dismantling of existing switch gear in the existing panel cubicle and replacing with 250A TP+NL(25kA) MCCB with all other accessories as required

1

-

-

... More
od263392/2023_2024 : Dismantling of energy meter box of cubicle consist of one number of TOD meter with CT and HRC fuses, switch gear and neutral link, interconnections, cabling.

1

-

-

... More
od263441/2023_2024 : HT METERING KIOSK-OUT DOOR HT Meteing Kiosk Supply, installation, testing and commissioning of Outdoor (IP54) TOD Metering kiosk, bi directional TOD meter (with RS485 communication facility) CT(0.2S) and PT(0.2), test terminal block, , control fuses, armoured copper cable between CT PT unit. The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54, weather proof, undergone seven tank process, powder coated finish ,earthing, entire civil work including suitable foundation and all mounting accessories as required complete as per the requirement of K.S.E.B The panel shall be with 630A aluminium PVC sleeved busbar ; support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control etc, seal off bushings, control wiring etc. HT HRC fuse 20A - 3 nos Seal off Bushing - 1 set, 110V Class 0.2s bi directional TOD meter- 1no. Shunt trip coil, 230V AC - 1 set Space heater with thermostat - 1 set Suitably rated Aluminium busbars and support insulators ON-OFF indication- 1 set The rate is inclusive of transportation, insurance, lift, lead and all associated works. The panel shall be with bottom entry to receive incoming , outgoing cable, all necessary interconnection, accessories as per particular specification , single line diagram. The metering cubicle shall have glass window for meter reading.

1

-

-

... More
SOLAR WORKS

-

-

-

... More
od25481/2024_2025 : Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 545 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box , Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections , Interconnections by supplying , fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying , fixing of necessary channel/conduit lugs and other accessories etc. as required. (Cost for 1kWp as each in unit)

32

-

-

... More
HVAC EQUIPMENTS

-

-

-

... More
od174338/2023_2024 : Supply, Installation, Testing and Commissioning of following minimum 5.5 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The efficiency of the equipment shall meet ECBC standards and shall comply with relevent ASHRAE standards. The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od174155/2023_2024 : Supply, Installation, Testing and Commissioning of following minimum 4.0 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The efficiency of the equipment shall meet ECBC standards and shall comply with relevent ASHRAE standards. The item shall be complete in all respects complying with technical specifications.

2

-

-

... More
od174156/2023_2024 : Supply, Installation, Testing and Commissioning of following minimum 3.0 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The efficiency of the equipment shall meet ECBC standards and shall comply with relevent ASHRAE standards. The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od174157/2023_2024 : Supply, Installation, Testing and Commissioning of following minimum 2.0 TR capacity Air-cooled DX Outdoor unit with variable speed inverter driven compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc. Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between Indoor Unit and Outdoor Unit, power cabling between isolator and outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation with vibration isolators etc. shall be included as part of equipment. The efficiency of the equipment shall meet ECBC standards and shall comply with relevent ASHRAE standards. The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od174374/2023_2024 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 2200 CFM- (5.5 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od174158/2023_2024 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of following minimum 1600 CFM- (4.0 TR) capacity complete with outlet volume control dampers ,canvas connections, ,UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/sq.ft. of coil surface area for equal distribution, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE3 or better, 3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, VFD, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od123910/2024_2025 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 1600 CFM- 4 TR capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications

1

-

-

... More
od174159/2023_2024 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of minimum 1200 CFM- (3.0 TR) capacity complete with outlet volume control dampers ,canvas connections, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE 3 ,3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od174160/2023_2024 : Supply, Installation, Testing and Commissioning of Double skin type Ceiling Suspended unit of following minimum 800 CFM- (2.0 TR) capacity complete with outlet volume control dampers ,canvas connections, ,UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/sq.ft. of coil surface area for equal distribution, Filter sections with MERV-7 and MERV-14 filters placed in downstream complying to ASHRAE 52.2 standard, cooling coil of copper tube (Inverter DX compatibility),aluminium fin construction, squirrel cage, TEFC, IE3 or better, 3-Ph induction motor, SS Drain Pan, DIDW centrifugal fan, drive package and cushy-foot mounting, control wiring for actuators, all housed inside housing of a double skin construction of 0.8mm pre-plasticized / pre coated Galvanized sheet steel(GSS) minimum 120 GSM and 0.8mm Al Zinc sheet or 275 GSM 0.8mm thick(GSS) inside with insulation of minimum 40 mm thick CFC free PUF injected insulation of 40 kg/m3 density (min.) with K factor not exceeding 0.04 W/ sqm°C, thermo break profile, VFD, GI support, necessary vibration isolation arrangement,thermostat, Limit switch in door and inspection lamps to be fixed, suitable starter and control panel as required, thermostat wiring, power wiring and associated control wiring. Minimum external static pressure of CSU shall be 25 mm wc. (External Static Pressure requirements shall be exclusive of filters). The item shall be complete in all respects complying with technical specifications.

1

-

-

... More
od174737/2023_2024 : Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 5.5 TR machine between indoor , outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ requirements, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications

16

-

-

... More
od174161/2023_2024 : Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 4.0 TR machine between indoor , outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications

31

-

-

... More
od174162/2023_2024 : Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 3.0 TR machine between indoor , outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications

12

-

-

... More
od174163/2023_2024 : Supply, Installation, Testing and Commissioning of suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) for 2.0 TR machine between indoor , outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth. The item shall be complete in all respects complying with technical specifications

14

-

-

... More
od174164/2023_2024 : Supply, Installation, Testing and Commissioning of minimum 1.0 TR capacity Decorative(Hi wall) Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and indoor units for single phase 230 V supply minimum 5 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitable sized (diameter) copper refrigerant piping (for both suction and liquid piping) between indoor , outdoor units, duly insulated with suitable thick closed cell elastomeric Class 0 insulation complying to minimum R value meeting ECBC+ standards, complete insulation shall be finished with factory laminated 7 mils glass cloth with required pipe fittings and accessories like bends, tees, reducers, supports complete, necessary power/control cabling as required, suitably supported on trays/ split clamps etc., PVC condensate drain pipe 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, finished with 7 mils factory laminated treated fibre glass cloth, first charge refrigerant gas R410A/R407C, cordless remote etc. The item shall be complete in all respects complying with technical specifications.

2

-

-

... More
od106894/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel other accessories etc. complete in all respects as per technical specifications. 100 CFM -15 mm WG

2

-

-

... More
od107015/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel other accessories etc. complete in all respects as per technical specifications. 700 CFM -15 mm WG

1

-

-

... More
od106895/2021_2022 : Supply, installation, testing and commissioning of suitable dia PVC condensate drain pipe of 6kg/sq.cm connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth along with required pipe fittings and accessories like Bends, Tees, reducers, clamps, suitably supported etc. complete in all respects as per the technical specifications.

30

-

-

... More
AIR DISTRIBUTION SYSTEM

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006: 0.63mm (24 guage)

207

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006: 0.80mm (22 guage)

15

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006: 1.00mm (20 guage)

5

-

-

... More
od174577/2023_2024 : Supply, Installation, Testing and Commissioning of Air-Distribution Network made out of suitable thick (gauge) Aluminium sheet for Supply air, Return air, Exhaust Air, Fresh Air rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. associated accessories, supports etc. for critical rooms(X-Ray /MRI/CT room etc.) application and as per relevant SMACNA standards etc. The item shall be complete in all respects complying with technical specifications.

34

-

-

... More
od325081/2023_2024 : Supplying and fixing of Closed cell nitrile rubber insulation with factory laminated Aluminium FSK facing of 12 micron thickness as mentioned in technical specification ,40-60 kg/m3 density, Butt all joints tightly and seal all breaks and joints by adhering glass cloth tape, fixing of insulation using OEM recommended  fixing  details ,supports and  adhesive, tapes etc. complete in all respects as required by the  technical specifications.The thickness of insulation shall be as per ECBC requirements to meet the temperature conditions of Inside:14 Deg C and Outside 40 Deg C or 19 mm thickness whichever is higher. The item shall be complete in all respects complying to technical specifications.

261

-

-

... More
od174588/2023_2024 : Supply, Installation, testing and commissioning of Acoustic Insulation of ducts using open cell nitrile rubber having a density of 140-180 kg/m3 and thickness of 10 mm with anti-microbial protection as per EN ISO 846 Method A etc along with manufacturer recommended adhesive where the VOC level should not exceed more than 850 grams / Litre as per IGBC/ GRIHA. Insulation material shall be GRIHA Approved and CFC, HCFC free. Insulation shall be dust and fibre free, complete in all respects as required by the technical specification

80

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

3

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

3

-

-

... More
od106896/2021_2022 : Supply, Installation , testing and commissioning of Aluminium extruded fresh air louvers with fresh air damper, removable filter, insect screen, bird screen etc. complete in all respects as per the technical specifications.

1

-

-

... More
od106897/2021_2022 : Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers with damper,bird screen etc.complete in all respects as per technical specifications.

1

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

3

-

-

... More
od106898/2021_2022 : Supply, Installation, testing , commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for Air Distribution Networks complete in all respects as per the technical specifications.

3

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od173964/2023_2024 : Supply, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, end suction, centrifugal type pump of cast iron body , bronze impeller with stainless steel shaft, mechanical seal having rated flow of 2280 lpm at 70m head, conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor conforming to IS 12615 specifications, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered along with anti vibration pads/mounts.

1

-

-

... More
od173967/2023_2024 : Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification.(a) Horizontal, end suction, centrifugal type pump of cast iron body , bronze impeller with stainless steel shaft, mechanical seal having rated flow 2280 lpm at 70m head, conforming to IS 1520.(b) Suitable HP, suitable RPM water cooled radiator type diesel engine conforming to relevant BS , IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,12v 180AH Battery and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity for 8 hour operation) with level indicator, Bypass line, piping from diesel tank to engine, exhaust pipe extended upto 1m outside pump house duly insulated with 50 mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads/ mounts. (e) Diesel engine control panel.

1

-

-

... More
od173972/2023_2024 : Supply, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Vertical Inline pump of stainless steel body and stainless steel impeller withstainless steel shaft, mechanical seal having rated flow of 180 lpm at 70m head conforming to IS 1520 having minimum mechanical efficiency of 75%.(b) Suitable HP Squirrel cage IE3 induction motor conforming to IS 12615 specifications, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation.

1

-

-

... More
od173976/2023_2024 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8 BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

3

-

-

... More
od173979/2023_2024 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4 BSP(F) connection with IP rated enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC, with ball valve etc. complete as required as per technical specification.

3

-

-

... More
od173983/2023_2024 : Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
od174367/2023_2024 : Supply, Installation, Testing and Commissioning of 200 mm nominal dia (6.3 mm thickness) MS(Heavy C' Class) pipe IS: 3589 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

24

-

-

... More
od173987/2023_2024 : Supply, Installation, Testing and Commissioning of 150 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

92

-

-

... More
od173988/2023_2024 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

61

-

-

... More
od173990/2023_2024 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

39

-

-

... More
od173992/2023_2024 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

51

-

-

... More
od173993/2023_2024 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

39

-

-

... More
od173994/2023_2024 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

105

-

-

... More
od173995/2023_2024 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

30

-

-

... More
od173996/2023_2024 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer , two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

455

-

-

... More
od173997/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 150 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation , providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

237

-

-

... More
od173998/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation , providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

7

-

-

... More
od173999/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 150 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

2

-

-

... More
od174000/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

1

-

-

... More
od174001/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 65 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

1

-

-

... More
od174516/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 200 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc complete as required as per the technical specification and conforming to IS 13095.

2

-

-

... More
od174002/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 150 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

8

-

-

... More
od174003/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

6

-

-

... More
od174005/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 65 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

1

-

-

... More
od174006/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 40 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all Accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

4

-

-

... More
od174007/2023_2024 : Providing, installation, testing and commissioning of 150 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

2

-

-

... More
od174554/2023_2024 : Providing, installation, testing and commissioning of 100 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od174008/2023_2024 : Providing, installation, testing and commissioning of 80 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od174009/2023_2024 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification.

7

-

-

... More
od174010/2023_2024 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve , nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) , M.S. Pipe

4

-

-

... More
od174011/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

14

-

-

... More
od174012/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

7

-

-

... More
od174013/2023_2024 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

7

-

-

... More
od174014/2023_2024 : Supply, installation, testing and commissioning of 4-WAY FIRE BRIGADE inlet connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap , Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

2

-

-

... More
od174015/2023_2024 : Supply, installation, testing and commissioning of draw off connection with CI body and gunmetal coupling, complete with GI nuts, bolts, gasket etc as required as per technical specification.

1

-

-

... More
od174016/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage pendant type sprinkler;1/2 NPT, K -5.0, Chrome Finish with rosetter plate; operating temperature at 68 degC complete as required as per the technical specification.

63

-

-

... More
od174017/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage upright type sprinkler ;1/2 NPT, K -5.0, Chrome Finish; operating temperature at 68 degC complete as required as per the technical specification.

117

-

-

... More
od175060/2023_2024 : Supply, installation, testing and commissioning of 700 mm braided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc as required as per technical specification.

59

-

-

... More
od174018/2023_2024 : Supply, installation, testing and commissioning of 1m unbraided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc and other accessories as required as per the technical specification.

9

-

-

... More
od174019/2023_2024 : Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification.

1

-

-

... More
od174020/2023_2024 : Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1 to 6 . The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 complete with all accessories as required as per the technical specification.

4

-

-

... More
od174021/2023_2024 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification.

3

-

-

... More
od373176/2023_2024 : Supply and installation of fire bucket stand for 4 no's bucket including supply of buckets.

1

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od173963/2023_2024 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

10

-

-

... More
od173970/2023_2024 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

4

-

-

... More
od173974/2023_2024 : Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

4

-

-

... More
od173977/2023_2024 : Supply, installation, testing and commissioning of Modular (Cealing mounted) ABC type extinguisher of 5Kg complete as required with all necessary accessories for successful operation as required as per the technical specification.

4

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
od173966/2023_2024 : Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke , heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

142

-

-

... More
od173969/2023_2024 : Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

16

-

-

... More
od173973/2023_2024 : Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

8

-

-

... More
od173975/2023_2024 : Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

10

-

-

... More
od173981/2023_2024 : Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring and control, as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

4

-

-

... More
od173982/2023_2024 : Supply, installation, testing and commissioning of addressable relay module to automatically trigger on/off 3rd party devices like fire damper, jet fans, extract air fans etc in case of fire, complete with all accessories as required as per the technical specification. The product shall be UL listed and FM Approved.

4

-

-

... More
od173984/2023_2024 : Supply, installation, testing and commissioning of 24V Power supply unit for hooters with battery backup. The status of the power supply unit must be monitored from the FACP and alarm shall be obtained if the power supply unit fails to operate, complete in all respect with necessary accessories as required as per the technical specification.

1

-

-

... More
od173985/2023_2024 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

8

-

-

... More
od173986/2023_2024 : Supply, installation, testing and commissioning of public address and talk back system consisting of 10 zone public address cum talk back console with mike and selector, multiple channel talk back facility, power supply, battery charger, battery housing, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier, and suitable capacity battery (min 12V), etc. complete as required for meeting the technical specifications.

1

-

-

... More
od173989/2023_2024 : Supply, installation, testing and commissioning of EN/UL/FM/LPCB approved/ listed, microprocessor based intelligent addressable main fire alarm panel having suitable number of loops to connect all the devices as per BOQ in single panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to integrate with analog/digital voice evacuation system (PA-talkback system) and shall be complete with all necessary accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers.

1

-

-

... More
od173991/2023_2024 : Supply and laying of 2x1.5 sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground,on wall surface or recess as required as per the technical specifications.

2200

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

80

-

-

... More
SIGNAGES

-

-

-

... More
od173965/2023_2024 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws , double tape or hanged from the false ceiling with the help of chain , screws etc. complete as required as per the technical specification.

14

-

-

... More
od173968/2023_2024 : Supply and installation of photoluminescent glow signage for FIRE ASSEMBLY POINT of standard size (500*225 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws , double tape or hanged from the false ceiling with the help of chain , screws etc. complete as required as per the technical specification.

1

-

-

... More
od173971/2023_2024 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws , double tape or hanged from the false ceiling with the help of chain , screws etc. complete as required as per the technical specification.

8

-

-

... More
od173978/2023_2024 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws , double tape or hanged from the false ceiling with the help of chain , screws etc. complete as required as per the technical specification.

8

-

-

... More
od173980/2023_2024 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

4

-

-

... More
ELEVATOR SYSTEM

-

-

-

... More
od108629/2021_2022 : Design, fabrication, supply, installation, testing and commissioning of electric traction type with machine room type , Stainless steel 26 Pax (1768 Kg) Hospital elevator with car size of 1600 mm (width) x 2400 mm (depth) (including freight , landing charges,insurance and all applicable taxes and duties in country of origin and in India etc- except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,braille buttons,audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required.The traction motor of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specification. The energy performance of the lift shall meet or exceed energy efficiency class B in accordance with IS 17515 standards. Having automatic centre/side opening stainless steel doors,Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm Fluted SS sheet flooring as applicable in accordance of following details:-4 stops , 4 openings and entrance , exit at same side and suitable for travel height of 12.3 mtrs. (Shaft Size 2400mm (width) x 3000mm (depth) ) with door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible .All components, fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications .

1

-

-

... More
STRUCTURED CABLING AND ACTIVE DEVICES

-

-

-

... More
od109597/2021_2022 : Supply, Installation, Testing and Commissioning of U/UTP cable - Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site as per technical specification.

1900

-

-

... More
od109602/2021_2022 : Supply, Installation, Testing and Commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site as per technical specification.

2000

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1300

-

-

... More
od109609/2021_2022 : Supply and installation of concealed GI metal backbox with all accessories required at site to complete the work as per technical specification

55

-

-

... More
od109614/2021_2022 : Supply, Installation, Testing and Commissioning of CAT6A information Outlet, RJ 45 with all accessories required at site including termination complete as per technical specification

47

-

-

... More
od109616/2021_2022 : Supply, Installation, Testing and Commissioning of CAT6 information Outlet, RJ 45 with all accessories required at site including termination complete as per technical specification

36

-

-

... More
od109617/2021_2022 : Supply, Installation, Testing and Commissioning of CAT6A 24 port patch panel with shutter fully loaded, with all accessories required at site including termination complete as per technical specification.

3

-

-

... More
od109618/2021_2022 : Supply, Installation, Testing and Commissioning of CAT6 24 port patch panel with shutter fully loaded, with all accessories required at site including termination complete as per technical specification.

3

-

-

... More
od109619/2021_2022 : Supply, Installation, Testing and Commissioning of Single/ Dual Shuttered Face Plate with all accessories required at site complete as per technical specification.

55

-

-

... More
od109620/2021_2022 : Supply, Installation, Testing and Commissioning of Cat6A Patch Cord - 2m with end termination for both data and voice with all accessories required at site complete as per technical specification.

52

-

-

... More
od109621/2021_2022 : Supply, Installation, Testing and Commissioning of Cat6 Patch Cord - 2m with end termination for both data and voice with all accessories required at site complete as per technical specification.

49

-

-

... More
od109622/2021_2022 : Supply, Installation, Testing and Commissioning of Cat6 Patch Cord - 1m with end termination for both data and voice with all accessories required at site complete as per technical specification.

35

-

-

... More
od109623/2021_2022 : Supply and installation of PVC casing capping with all accessories required at site to complete the work as per technical specification.

20

-

-

... More
od109624/2021_2022 : Supply, Installation, Testing and Commissioning covered GI unperforated cable tray with 200 mm width X 50 mm depth X 1.6 mm thickness (ISI Grade) with thread road, anchor fastener, nut , washer, etc. including all necessary accessories required at site complete as per technical specification.

150

-

-

... More
od109625/2021_2022 : Supply, Installation, Testing and Commissioning of 24 Port Stackable switch - Layer 2, 24 x 10/100/1000Base-TX ports with 2 x Copper / SFP+ ports with all necessary hardware , accessories, etc. as required at site complete as per technical specification.

2

-

-

... More
od109626/2021_2022 : Supply, Installation, Testing and Commissioning of 24 port Core Switch - Layer 3 Switch with min 12 x 10/100/1000Base-TX ports and min 4x10G Copper / SFP+ ports, with all necessary hardware , accessories, etc. as required at site complete as per specification.

1

-

-

... More
od109627/2021_2022 : Supply, installation, testing and commissioning of next generation Firewall having a capacity of handling 100 concurrent users with logs, monitoring, bandwidth management, security subscriptions, including software, licenses and all accessories required at site to complete the work as per technical specification

1

-

-

... More
od109628/2021_2022 : Supply, installation, testing and commissioning of 42U Network Rack (800mmx1000mm) along with all necessary hardware , accessories, etc. required at site complete as per technical specification.

2

-

-

... More
IP-PBX

-

-

-

... More
od109596/2021_2022 : Supply, installation, testing and commissioning of IP-PBX system with 2 PRIs and 10 channel SIP trunk licenses, expandable up to 120 IP extensions, including all hardware, software, 1 no of desktop based operator console, with all accessories required at site to complete the work as per technical specification

1

-

-

... More
od109603/2021_2022 : Supply, Installation, Testing and Commissioning of licence of IP extensions with all accessories required at site complete as per technical specification.

34

-

-

... More
od109606/2021_2022 : Supply, installation, testing and commissioning of Standard IP Phones with all accessories required at site complete as per technical specification.

34

-

-

... More
od109611/2021_2022 : Supply, Installation Testing and Commissioning of 24 port PoE+ Stackable switch - Layer 2 with 24 x 10/100/1000Base-TX PoE+ ports and 2 SFP ports with all accessories required at site complete as per technical specification.

2

-

-

... More
IP SURVEILLANCE

-

-

-

... More
od109601/2021_2022 : Supply, Installation, Testing and Commissioning of 2MP varifocal IP camera, PoE, IP66 rated with all accessories required at site complete as per technical specification.

14

-

-

... More
od109605/2021_2022 : Supply, Installation Testing and Commissioning of 24 port PoE+ switch - Layer 2 with 24 x 10/100/1000Base-TX PoE+ ports and 2 SFP ports with all accessories required at site complete as per technical specification.

1

-

-

... More
od109607/2021_2022 : Supply, installation, testing and commissioning of 16 channel Network Video Recorder, SAS/Enterprise HDDs, RAID5 with 30 days storage, all required hardware including a desktop, cabling and accessories as required at site to complete the work as per technical specification.

1

-

-

... More
od109612/2021_2022 : Supply, Installation, testing and commissioning of 55 commercial display 24/7 with HDMI, USB ports with all accessories required at site complete as per technical specification.

1

-

-

... More
ATTENDANCE SYSTEM

-

-

-

... More
od109600/2021_2022 : Supply, installation, testing and commissioning of Biometric, Password and Proximity card based attendance machine, software etc. with all accessories required at site complete as per specification.

1

-

-

... More
PUBLIC ADDRESS AND EVACUATION SYSTEM

-

-

-

... More
od109599/2021_2022 : Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm

1000

-

-

... More
od109604/2021_2022 : Supplying, installation, testing , commissioning of 1.5/3/6W ceiling speaker complete as required

21

-

-

... More
od109608/2021_2022 : Supplying, installation, testing , commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

43

-

-

... More
od109610/2021_2022 : Supply, Installation, testing and commissioning of 120W power amplifier with all accessories required at site complete as per technical specification.

2

-

-

... More
od109613/2021_2022 : Supply, Installation, testing and commissioning of PA System Controller capable of managing upto 6 individual zones with BGM, announcement and automatic emergency message facility with integration to Fire alarm system with all accessories required at site complete as per technical specification.

1

-

-

... More
od109615/2021_2022 : Supply, Installation, testing and commissioning of Paging Microphone with multi tone chime and multi-channel zone selector with all accessories required at site complete as per technical specification.

1

-

-

... More
MGPS Works

-

-

-

... More
od222194/2023_2024 : Supply,testing and commissioning  of Automatic  Oxygen Control Panel with minimum flow rate of 1500 LPM,; Fully complying  with ISO 10524-2, ISO 7396-1:2007/HTM02-01 as per technical specifications. The cylinders shall not be included in the quoted price.

1

-

-

... More
od222381/2023_2024 : Supply,testing and commissioning  of Oxygen Manifold  - 2 banks x6 cylinders, as per technical specifications. The cylinders shall not be included in the quoted price.

1

-

-

... More
od222471/2023_2024 : Supply,testing and commissioning of Cylinder Emergency Oxygen Manifold - 2 Bank x 2 Cylinders wih high flow regulator, The cylinders shall not be included in the quoted price.

1

-

-

... More
od223176/2023_2024 : NITROUS OXIDE SYSTEM: Supply,testing and Commissioning of N2O Manifold with high flow regulator - 1 Bank x2 Cylinders , The cylinders shall not be included in the quoted price.

1

-

-

... More
od223177/2023_2024 : Supply,testing and commissioning of Emergency N2O Out let with Convertion Kit (Convertion Kit- 2nos)

1

-

-

... More
od223178/2023_2024 : MEDICAL AIR SYSTEM: Supply,testing and commissioning  of 7.5HP Compressed air plant complete with - 2 compressors, each compressor  should have minimum free air delivery of 750 LPM, 1 air receiver-1000ltrs, 2 air purification  system to ensure medical air quality as per HTM 02-01 guidelines,  pressure reducing station, control panel, automatic  drain valves, ball valves etc and as per technical specifications.

1

-

-

... More
od222472/2023_2024 : VACUUM PLANT: Supply,testing and commissioning of 5 HP Vacuum plant complete with 1 vacuum pump and one as standby, each vacuum pump should have minimum free air aspirated of 1600LPM betwen 570 mmHg and 720 mm Hg.min, vaccum receiver tank of minimum2000ltr capacity,bacteria double filter, valves,pressure guages,NRV, electrical control panel including circuit breakers, pressure switches, timers, ball valves etc as per technical specifications.

1

-

-

... More
od223203/2023_2024 : Supply,testing and commissioning of Master Plant Alarm Panel ,Complies with HTM 02-01/ISO7396-1 Standards. Each Master Alarm should be modular in design and be fitted with required number of master alarm modules. The master alarms should be capable to monitor minimum 25 point. Each point represents an alarm condition that the source equipment might have. When an alarm condition exists, a red-light flashes and the audible alarm sounds. If several alarm conditions occur simultaneously, the most recent alarm light should flash, while the other alarm lights should remain lit. When an alarm condition is generated, an audible alarm should be actuated. A dry contact module should be available to interface with a building management system. The box material should be of gauge steel of requisite thickness and equipped with mounting brackets. The emissions from alarms should conform with EMC standards. Master alarm management system should be designed to display alarm conditions from the source supply units indicating the broad status of the source equipment and manifolds as well as the master distribution status from the source supplies. Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. Each panel shall display and/or input of multi point alarms,including all necessary cabling between mater alarm and floor panels. The master alarm must be able to monitor the following source alarm conditions. as per technical specifications.

1

-

-

... More
od222382/2023_2024 : Combined Electrical Control panel with wiring for Air compressor , vaccum Pump system as per technical specification.

1

-

-

... More
od222418/2023_2024 : Supply,installation testing and commissioning  of Copper pipe: Per Mtr. It must comply with EN 13348  as per technical specifications. -15 mm x 0.9 mm thick copper pipe

458

-

-

... More
od222419/2023_2024 : Supply,installation testing and commissioning  of Copper pipe: Per Mtr. It must comply with EN 13348  as per technical specifications-22 mm x 0.9 mm thick Copper pipe

300

-

-

... More
od222420/2023_2024 : Supply,installation testing and commissioning  of Copper pipe: Per Mtr. It must comply with EN 13348  as per technical specifications. -28 mm x 0.9 mm thick Copper pipe

100

-

-

... More
od222421/2023_2024 : Supply,installation testing and commissioning  of Copper pipe: Per Mtr. It must comply with EN 13348  as per technical specifications. -35 mm x 1.2 mm thick Copper pipe

70

-

-

... More
od222383/2023_2024 : Supply,Installation , testing and commissioning  of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-O2 Outlets with Probes

37

-

-

... More
od222384/2023_2024 : Supply,Installation , testing and commissioning  of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-N2O Outlets with Probes

1

-

-

... More
od222385/2023_2024 : Supply,Installation , testing and commissioning  of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications- Air ( 4 bar) Outlets with Probes

19

-

-

... More
od222386/2023_2024 : Supply,Installation , testing and commissioning  of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Air (7 bar) Outlets with Probes

1

-

-

... More
od222387/2023_2024 : Supply,Installation , testing and commissioning  of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Vacuum Outlets with Probes

31

-

-

... More
od223821/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-3 gas - 1 O2, 1M air, 1 Vac

4

-

-

... More
od223822/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-5 gas- 1O2,1 N2O, IM air , 1 s air, 1 vac

1

-

-

... More
od223823/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-15 mm

30

-

-

... More
od223824/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-22 mm

10

-

-

... More
od223825/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-28mm

15

-

-

... More
od223826/2023_2024 : Supply,testing and commissioning of class J type Oxygen Gas filled Cylinder etc in complete as per technical specification.

16

-

-

... More
od223827/2023_2024 : Supply,testing and commissioning of J type Nitrous Oxide Gas filled Cylinder as per technical specification.

3

-

-

... More
od223828/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge.

17

-

-

... More
od222388/2023_2024 : Supply Installation of BPC Oxygen Flow meter as per technical specification.

18

-

-

... More
od222389/2023_2024 : Supply Installation of Ward vacuum unit with 600 ml collection jar asper technical specification.

17

-

-

... More
od222390/2023_2024 : Supply Installation of Theatre Vacuum   unit with trolly and 2000 ml collection jar as per technical.

2

-

-

... More
od222391/2023_2024 : Supply,Installation,testing and commissioning of Anesthesia Pendent Single Arm

1

-

-

... More
od222393/2023_2024 : BHP Suction Clamp

17

-

-

... More
od222394/2023_2024 : BHP IV Stand

17

-

-

... More
od222395/2023_2024 : BHP Monitor Tray

17

-

-

... More
od222396/2023_2024 : Supply,Installation,testing and commissioning of High Pressure Antistatic Hose with color coded.

20

-

-

... More
Furniture

-

-

-

... More
od338610/2023_2024 : Revolving chairs Medium back chair :-The cushioned seat assembly shall consists of moulded polyurethane foam upholstered with fabric. The foam is assembled over a 12mm thick hot pressed plywood . The back shall made up of two piece injection moulded frame. The inner frame shall be upholstered with mesh fabric and mounted on the main assembly.Lumber support made up of injection moulded in black P.P and upholstered with PU foam. Lumber support size 16 cm (W) x 9 cm (H) at fixed position Size of back shall be (W)-55cm, (H)-58.0cm , size of seat shall be (W)-50 cm x (D)-44.0cm. Armrest is fixed arm rest. The arm top is made of soft moulded PU .The mechanism of chair shall have following features:360 degree revolving type, Synchro 1 mechanism, Tilt tension adjustment. The chair shall be provided with pneumatic height adjustment which shall have stroke of 95 +/- 5 mm. The pedestal shall be made of nylon. it shall be fitted with 5 nos twin wheel castor. The size of the pedestal shall be 65.0 +/- 1 cm pitch-centre-dia (70.0 +/- 1.0 cm with castors). The twin wheel castors shall be injection moulded in PP . Overall dimensions of Chair shall be, Width of Chair - 70.0cm, Depth of Chair - 70.0 cm as measured from pedestal below. Height from ground - min 102.5 to max 111.5 cm. Seat height - min 44.5 cm to max 53.5 cm. Dimensions tolerance / variations shall be within +/- 1 cm. Chair tested as per ANSI/BIFMA x5.1 standards.The product shall be of approved make and colour. The model shall be Wipro or equivalent.

20

-

-

... More
od340823/2023_2024 : Airport chairThree seater perforated metal bench -Cross beam and Leg shall be powder coated made of cold rolled steelwith 0.2 ± 0.01 cm thickness. Seat-Back shell shall be 1.2 mm thk powder-coated perforated shell made from cold rolled M.S. sheet 0.12 ± 0.013 cm thickness. The Side Bar shall be made of powder-coated solid steel. The Shell shall be assembled on the Cross Beam with help of bolts . Seat width- 54.5 cm per seat. Thickness of side bars is 4.5cm , gap between seats is 2cm. Overall Dimensions shall be Seat Height - 40.6 cm, Height - 77.5cm, Width , Depth of Chair as measured from ground - Width-176.5 cm and Depth-71 cm.Dimensions tolerance / variations shall be within +/- 1 cm. The model shall be Wipro or equivalent.

36

-

-

... More
od338625/2023_2024 : Office table Providing and installing Main Table: Material using Top,Leg,Front panel using IS 710 BWP Marine Plywood (Make - Archid/Century/Green Ply). Lamination using 1 MM (Make Archid Lam / Merino / Century / Greenlam). The plywood with lamination shall be hot / cold press machine required.The front panel provided at an offset of 150 MM from the outer edge. Providing Key Board Tray CPU STand , Foot Rest etc. All the visible edges are covered with 2x22MM , .5x22MM PVC Edge band wherever required.The Table fully using knockdown fittings of Mini Fix System Make - Ebco. Providing 7.2 MM Golden Steel Beeding on the front panel of the same (Size considered: 150x75x75cm)

8

-

-

... More
od339332/2023_2024 : Visitor chair (single)Providing , amp; installing in Position Medium Back Visitor Chair with the following specifications. Seat , amp; Back shall be Fabric upholstered/Mesh Back with 100% Polyester and weighing 320 GLM. Seat Foam shall be made out of PU foam with a density 50-60 Kg/m. Base shall be Mild Steel 4 Legged base powdercoated mounted on PVC bush. The Back rest shall be of dimension 610mm (H) X 425mm (W). Seat Size shall be of dimension 455mm (W) X 480mm (D). The product shall be BIFMA compliant.

12

-

-

... More
od339408/2023_2024 : EXAMINATION TABLE SS 304 Features, Specification and Accessories : ● Backrest position achived by Ratchet Mechanism. ● Two sectional top made of SS304 sheet with 1mm thick. ● SS tubular frame made up of SS 304 round Pipes Ø32mm Round Pipe 18G Thickness for Legs and horrizontal cross pipe of Ø25mm round Pipe of 18 thickness. ● IV Stand Provinsion Provided. ● Overall size(Approx.): 1860 L mm x 540 W mm x 810 H mm ● Mattress 2 thickness, 32 density standard

2

-

-

... More
od339435/2023_2024 : Steel rack Supply and installing steel Slotted Angled Iron Rack with 6 Pannel (Size considered here: 1800x900x380 cm) 20g

4

-

-

... More
od338626/2023_2024 : Almirah Material using IS 710 BWP Marine Ply Wood (Make - Archid/Century/Green Ply) Lamination using 1 MM (Make Archid Lam / Merino / Century / Greenlam). The ply wood with lamination shall be hot / cold press machine required.Interior lamination using .8 MM (Make : Archid Lam / Merino / Century / Greenlam).All the visible edges are covered with 2x22MM , .5x22MM PVC Edge band wherever required. Back Panel using 9MM thick BWP Grade marine plywood IS 710 grade marine ply wood with .8 MM thick interior lamination. Hardware using 90 Degree Soft Close Hinges , Multipurpose lock, D Handles etc Make - Ebco. Unit fully installed by knockdown fitting - Minifix system Make - Ebco Size vary from Length 80cm -240cm, Width 45CM, Hight 90cm to 210cm. Size considered here 90x45x210cm x 28 Nos

5

-

-

... More
od338630/2023_2024 : PATIENT'S REVOLVING STOOL FULL SS 304 Features, Specification and Accessories : ● Round-revolving top, Ø300mm, made of SS304 sheet of 1.2mm thickness. ● Four legged stool, made of Ø25mm SS304 round tubes of 1.2mm thickness, mounted on central base pipe of Ø50mm SS304 round pipe with 1.6mm thickness. ● Height adjustable by screw thread rod mechanism. ● Overall size(Approx.): 350 L mm x 350 W mm x 520- 635 H mm

5

-

-

... More
od338631/2023_2024 : BED SIDE LOCKER ECONOMY FULL SS304 Features, Specification and Accessories: ● Made of SS304 tubes and sheets. ● Top made of SS 304 sheet with 1mm thick. ● Frame made of 25X25mm SS square pipe with 1.2mm thick also provide verical tubular support. ● Provided with one storage box and a door made of SS304 sheet with 1.2mm thickness. ● Overall size(Approx.) : 400 L mm x 400 W mm x 810 H mm.

10

-

-

... More
od339446/2023_2024 : High back chair(x-ray department)Chair -Highback :- The seat shall made up of plywood and moulded polyurethane foam upholstered with fabric. Backrest assembly is of injection moulded plastic with black mesh fabric and height adjustable lumbar support pad and adjustable headrest. The moulded polyurethane foam for seat is with density=50-55 kg/m ³.The dimensions of seat shall be- 48 cm(W) x 45 cm(D) and of back shall be 46.5 cm(W) x 51.5 cm(H). Armrest has button operated height adjustment. The arm top is made of soft moulded PU with MS . The mechanism of chair shall have following features:360 degree revolving type, Synchronous 1 Mechanism.The chair shall be provided with Class 4 pneumatic height adjustment which shall have stroke of 112 mm. The pedestal shall be injection moulded in black GF nylon and fitted with 5 nos twin wheel castor. The size of the pedestal shall be 65.0 +/- 1 cm pitch-centre-dia (70.0 +/- 1.0 cm with castors). The twin wheel castors shall be injection moulded in black polypropylene. The cushioned head support is adjustable in height and angle for optimum user comfort. Overall dimensions of Chair shall be, Width of Chair - 70.0cm, Depth of Chair - 70.0 cm as measured from pedestal below. Height from ground - min 92.5 to max 103.0 cm. Seat height - min 41 cm to max 51.5 cm. Dimensions tolerance / variations shall be within +/- 1 cm. Chair tested as per ANSI/BIFMA x5.1 standards.The upholstery shall be fabrics with 100% polyester.The product shall be BIFMA compliant. The product shall be of approved make and colour. The model shall be Wipro ,Godrej or equivalent.

2

-

-

... More
od338632/2023_2024 : HOSPITAL BED ECONOMY (PLANE TOP) Features, Specification and Accessories : ● Plane top MS Hospital bed. ●Platform made of perforated Single section CRCA MS Sheet of 1.2mm thicknesss. ●Head and foot bows made of MS CR round tubes of Ø32mm with 1.2mm thickness with vertical tube support. ●Two provisions of SS IV pole towards corners positioned diagonally. ●All MS parts chemically Pre-treated and Epoxy powder coated. ●Frame size(Approx.): 1900 L mm x 900 W mm x 560 H mm ●Mattress(28 density)

4

-

-

... More
od338634/2023_2024 : Office executive table Providing and installing Examination Table: Material using Top,Leg,Front panel using IS 710 BWP Marine Plywood (Make - Archid/Century/Green Ply). Lamination using 1 MM (Make Archid Lam / Merino / Century / Greenlam). The plywood with lamination shall be hot / cold press machine required.The front panel provided at an offset of 150 MM from the outer edge. Providing Key Board Tray CPU STand , Foot Rest etc. All the visible edges are covered with 2x22MM , .5x22MM PVC Edge band wherever required.The Table fully using knockdown fittings of Mini Fix System Make - Ebco. Providing 7.2 MM Golden Steel Beeding on the front panel of the same Size: 150X75X75CM (Including 1 Mobile pedestal unit)

2

-

-

... More
od338637/2023_2024 : Providing and installing curtain rod frame with curtain cloth. Curtain rod using Aluminium frame with cloth upto a height of 220CM.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.