KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Jan 2025
Closing Soon31 Jan 2025
Tender Amount₹ 58,43,000 
Notes
Download

Costs

Summary

Development Of Taluk Hospital Malayinkeezhu Mgps

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od324238/2023_2024 Supply,testing and commissioning of Cylinder Emergency Oxygen Manifold - 1 Bank x4 Cylinders wih high flow regulator, The cylinders shall not be included in the quoted price.

1

-

-

... More
od324254/2023_2024 NITROUS OXIDE SYSTEM: Supply,testing and commissioning of automatic N2O control panel complete set with inlet and outlet connectors for fully automatic control panel for both sides with brass hosing and suitable connectors. ½” BSP (M) thread.

1

-

-

... More
od324255/2023_2024 Supply,testing and commissioning of Nitrous Oxide Manifold - 2 banks x 2 cylinders.as per technical specifications. The cylinders shall not be included in the quoted price.

1

-

-

... More
od324256/2023_2024 Supply,testing and commissioning of Emergency N2O Out let with Convertion Kit (Convertion Kit 2nos)

1

-

-

... More
od324342/2023_2024 CARBON DIOXIDE SYSTEM Supply,testing and commissioning of semi automatic CO2 control panel complete set with inlet and outlet with brass housing and suitable connectors. ½” BSP (M) thread.

1

-

-

... More
od324481/2023_2024 Supply,testing and commissioning of Cylinder CO2 Manifold - 1cylinder x 2 bank with all accessories required as per specification

1

-

-

... More
od326986/2023_2024 Supply,testing and commissioning of Emergency CO2 Out let with Convertion Kit (Convertion Kit 2nos)

1

-

-

... More
od324699/2023_2024 MEDICAL AIR SYSTEM: Supply,testing and commissioning of Compressed air plant complete with - 2 compressors, each compressor should have minimum free air delivery of 750 LPM @8.5 bars, 1 air receiver tank of minimum 1000 ltr capacity, filtration and dryer system to ensure medical air quality as per HTM standards (each compressor module should include an inline filter with particle retention of 10 microns), NRV, pressure reducing station,automatic drain valves,pressure guages,ball valves, electrical control panel including circuit breakers, starters, pressure switches, timers, as per technical specifications.

1

-

-

... More
od324893/2023_2024 VACUUM PLANT: Supply,testing and commissioning of Vacuum plant complete with 1 vacuum pump and one as standby, each vacuum pump should have minimum free air aspirated of 1500 LPM betwen 570 mmHg and 720 mm Hg.min, vaccum receiver tank of minimum 2000 ltr capacity,bacteria double filter, valves,pressure guages,NRV, electrical control panel including circuit breakers, pressure switches, timers, ball valves etc as per technical specifications.

1

-

-

... More
od324918/2023_2024 "Supply,testing and commissioning of Master Plant Alarm Panel ,Complies with HTM 02- 01/ISO 7396-1 Standards. Each Master Alarm should be modular in design and be fitted with required number of master alarm modules. The master alarms should be capable to monitor minimum 25 point. Each point represents an alarm condition that the source equipment might have. When an alarm condition exists, a red-light flashes and the audible alarm sounds. If several alarm conditions occur simultaneously, the most recent alarm light should flash, while the other alarm lights should remain lit. When an alarm condition is generated, an audible alarm should be actuated. A dry contact module should be available to interface with a building management system. The box material should be of gauge steel of requisite thickness and equipped with mounting brackets. The emissions from alarms should conform with EMC standards. Master alarm management system should be designed to display alarm conditions from the source supply units indicating the broad status of the source equipment and manifolds as well as the master distribution status from the source supplies. Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. Each panel shall display and/or input of multi point alarms,including all necessary cabling between mater alarm and floor panels. The master alarm must be able to monitor the following source alarm conditions. as per technical specifications."

1

-

-

... More
od324919/2023_2024 Combined Electrical Control panel with wiring for Air compressor & vaccum Pump system as per technical specification.

1

-

-

... More
od324931/2023_2024 Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc. as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-12mm x 0.7 mm thick copper pipe.

180

-

-

... More
od324932/2023_2024 Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc. as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-15 mm x 0.9 mm thick copper pipe

750

-

-

... More
od324933/2023_2024 Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-22 mm x 0.9 mm thick Copper pipe

450

-

-

... More
od324934/2023_2024 Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc. as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-28 mm x 0.9 mm thick Copper pipe

200

-

-

... More
od324935/2023_2024 Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-35 mm x 1.2 mm thick Copper pipe

100

-

-

... More
od324936/2023_2024 Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc. as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications-42 mm x 1.2 mm thick Copper pipe

40

-

-

... More
od324992/2023_2024 Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-O2 Outlets with Probes

65

-

-

... More
od324993/2023_2024 Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-N2O Outlets with Probes

3

-

-

... More
od324994/2023_2024 Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications- Air ( 4 bar) Outlets with Probes

16

-

-

... More
od324995/2023_2024 Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Air (7 bar) Outlets with Probes br

4

-

-

... More
od324996/2023_2024 Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Vacuum Outlets with Probes

58

-

-

... More
od324997/2023_2024 Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications- CO2 Outlets with Probes

2

-

-

... More
od324999/2023_2024 Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-3 gas - 1 O2, 1M air, 1 Vac

3

-

-

... More
Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-2gas - 1 O2, 1 Vac

4

-

-

... More
Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-5 gas- 1O2,1 N2O, IM air , 1 s air, 1 vac

1

-

-

... More
od325002/2023_2024 Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the /HTM 02-01/ISO 7396-1 requirements and should be CE Certified or. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications-6 gas- 1O2,IM air,1 N2O, 1 s air, 1 vac

2

-

-

... More
od325099/2023_2024 Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specificattions - 15mm

45

-

-

... More
od325100/2023_2024 Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-22 mm

10

-

-

... More
od325101/2023_2024 Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-28mm

10

-

-

... More
od325102/2023_2024 Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-35 mm

4

-

-

... More
od325103/2023_2024 Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-42 mm

4

-

-

... More
od325104/2023_2024 Supply,testing and commissioning of class J type Oxygen Gas filled Cylinder etc in complete as per technical specification.

20

-

-

... More
od325130/2023_2024 Supply,testing and commissioning of J type Nitrous Oxide Gas filled Cylinder as per technical specification.

5

-

-

... More
od326890/2023_2024 Supply,testing and commissioning of J type CO2 Gas filled Cylinder as per technical specification.

3

-

-

... More
od326670/2023_2024 Supply and installation of Bed Head 5ft(Horizontal) unit made out of High strength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge.

10

-

-

... More
od326825/2023_2024 Supply Installation of BPC Oxygen Flow meter as per technical specification.

46

-

-

... More
od326826/2023_2024 Supply Installation of Ward vacuum unit with 600 ml collection jar asper technical specification.

45

-

-

... More
od325148/2023_2024 Supply Installation of Theatre Vacuum unit with trolly and 2000 ml collection jar as per technical. .

6

-

-

... More
od325149/2023_2024 Supply,Installation,testing and commissioning of Anesthesia Pendent Single Arm

1

-

-

... More
od326774/2023_2024 BHP Suction Clamp

10

-

-

... More
od326775/2023_2024 BHP IV Stand

10

-

-

... More
od326776/2023_2024 BHP Monitor Tray

10

-

-

... More
od326777/2023_2024 Supply,Installation,testing and commissioning of High Pressure Antistatic Hose with color coded.

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.