KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Electrical and Electronics
Eprocure
Opening Date6 Sep 2022
Closing Date26 Sep 2022
Tender Amount₹ 3,40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od18841/2021_2022 : Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured 12C 2.5 Sq.mm copper conductor cable conforming to IS 7098 (Part 1) amended up to date.

250

-

-

... More
od152788/2021_2022 : Supply of 3.5C 70 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

470

-

-

... More
od152789/2021_2022 : Supply of 4C 16 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminiumconductor cable conforming to IS 7098 (Part 1) amended upto date.

1800

-

-

... More
od152790/2021_2022 : Supply of 4C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

652

-

-

... More
od152791/2021_2022 : Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 6 Cu

205

-

-

... More
od152792/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 2.5 sq.mm Cu

1200

-

-

... More
od152795/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. ,3.5C 185 Sq mm.

490

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

54

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

8

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

22

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

12

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

14

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

156

-

-

... More
od18856/2021_2022 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 4C 2.5 sqmm Cu

54

-

-

... More
od18859/2021_2022 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed aluminium/copper conductor cable of 1.1 kV grade as required. 3C 4sqmm Cu

52

-

-

... More
od18860/2021_2022 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 12C 2.5 sqmm Cu

10

-

-

... More
od19148/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.,2 X 6 sq. mm (19mm)

84

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

950

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

320

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

130

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

530

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

527

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

390

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

240

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

30

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

5

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

25

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

110

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

20

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

5

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1180

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

104

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

145

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

56

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

3000

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

260

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

155

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

140

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

65

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

90

-

-

... More
od18874/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron,cable tray (galvanization thickness not less than 50 microns) with perforation not,more than 17.5%, in convenient sections, joined with connectors, suspended from,the ceiling with G.l. suspenders including G.l. bolts , nuts, etc. as required.,300 mm width X 50 mm depth X 1.6 mm thickness

600

-

-

... More
od18875/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron,cable tray (galvanization thickness not less than 50 microns) with perforation not,more than 17.5%, in convenient sections, joined with connectors, suspended from,the ceiling with G.l. suspenders including G.l. bolts , nuts, etc. as required.,150 mm width X 50 mm depth X 1.6 mm thickness

350

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

49

-

-

... More
od18879/2021_2022 : Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured 3C 4Sq.mm copper conductor cable conforming to IS 7098 (Part 1) amended up to date.

1172

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

10

-

-

... More
od19174/2021_2022 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.,Group C

407

-

-

... More
od19175/2021_2022 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.,Group C

58

-

-

... More
od19176/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required,GROUP B

442

-

-

... More
od19177/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required,GROUP A

676

-

-

... More
od19178/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C

1972

-

-

... More
1.24.2 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

10

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

122

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

10

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

122

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

33

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

33

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

28

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

26650

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

17761

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

376

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

1784

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

1503

-

-

... More
od152339/2021_2022 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on,surface or in recess, including providing and fixing 6 pin 5/6 , 15/16 A modular,socket outlet and 15/16 A modular switch, connection etc. as required.

117

-

-

... More
1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm

62000

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

21127

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

8873

-

-

... More
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm

1273

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

28

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

90

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

28

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

36

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

4

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

5

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

7

-

-

... More
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

22

-

-

... More
od18835/2021_2022 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.

36

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1334

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

46

-

-

... More
od18850/2021_2022 : Supply and fixing of 40A DP Isolator in sheet steel enclosure with all other accessories as required complete,

18

-

-

... More
od18851/2021_2022 : Supplying and fixing following rating, four pole, 415 volts, MCCB in the existing DB complete with connections, testing and commissioning etc. as required.,100A FP MCCB 16 kA,

3

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

18

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

2

-

-

... More
od18855/2021_2022 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.,Triple pole

54

-

-

... More
od18857/2021_2022 : Supply installation, testing and commissioning of DOL starter upto 5HP,3ph motor including auxilliary contactors, 2kVAR capacitor and all necessary accessories as required complete with single phase preventor, function indiaction etc.

36

-

-

... More
od18858/2021_2022 : Supplying and fixing 25 amps rating, 230 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.,Double pole

25

-

-

... More
od18861/2021_2022 : Supplying and fixing 40 amps rating, 415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.,Four pole

103

-

-

... More
od18862/2021_2022 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required,4 pole 40 amps. (415 Volts),100mA sensitivity.,

4

-

-

... More
od18863/2021_2022 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required,4 pole 63 amps. (415 Volts),100mA sensitivity.,

16

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

25

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

60

-

-

... More
od157549/2021_2022 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB,Cable end box for Vertical TPN DB (MCCB incomer)

2

-

-

... More
od157550/2021_2022 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB,Cable end box for vertical DB (MCB incomer),

22

-

-

... More
od157551/2021_2022 : Supplying and fixing suitable size Cable end box with all accessories as required compete for the SPN , TPN MCB Horizontal distribution boards

2

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

7

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

314

-

-

... More
od18790/2021_2022 : Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required.

20

-

-

... More
od18797/2021_2022 : Supply and fixing of 12W(+/- 1W) LED lamp in the angle holder including all necessary accessories and connections as required complete suitable for 230V, 50 Hz, AC supply

117

-

-

... More
od18801/2021_2022 : Supply of LED Street Lighting luminaire of IP65 protected, pressure die cast aluminium housing body with optimal heat sink, with maximum system wattage of 40 W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 and system efficacy greater than or equal to 100. The luminaire shall be mounted on GI pipe with 0.5m overhang and necessory accessories and connection.

32

-

-

... More
od18808/2021_2022 : Supply of LED surface mounted down light made of die cast aluminium with proper diffusers, along with driver, maximum system wattage of 18 Watts,lumen output of lamp greater than 1800 lumens, power factor 0.9, rated life of L70 @ 50,000 hours and including all necessary accessories as required complete

520

-

-

... More
od18811/2021_2022 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser ,along with driver,maximum system wattage of 20 Watts,lumen output of lamp greater than 1500, power factor 0.9,rated life of L70 @ 50,000 hours, and including all the necessary accessories as required complete.

1145

-

-

... More
od18822/2021_2022 : Installation, testing and commissioning of pre - wired,LED/ fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

2533

-

-

... More
od18828/2021_2022 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser,along with driver,maximum system wattage of 10 Watts,lumen output of lamp greater than 900, power factor 0.9,rated life of L70 @ 50,000 hours and including all the necessary accessories as required complete.

388

-

-

... More
od19936/2021_2022 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10% including accessories like safety pin, nut bolts, washers. suitable to function with modular electronic regulator unit for speed control .Temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

868

-

-

... More
od19937/2021_2022 : Supply of LED bulkhead luminaire of IP65 protected, pressure die cast aluminium housing body with maximum system wattage of 10 W with rated life of L70 @ 50,000 hoursand system efficacy greater than or equal to 90%.

30

-

-

... More
od19938/2021_2022 : Supply of LED wall mounted decorative light fitting made of steel with proper diffusers, LED bulb of maximum wattage of 27 Watts and including all necessary accessories as required complete,

188

-

-

... More
od19939/2021_2022 : Supply of LED recess mounted down light made of die cast aluminium with proper diffusers, along with driver, maximum system wattage of 18 Watts,lumen output of lamp greater than 1800 lumens, power factor 0.9, rated life of L70 @ 50,000 hours and including all necessary accessories as required complete.

20

-

-

... More
od18837/2021_2022 : Installation, testing and commissioning of High bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.

32

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

4000

-

-

... More
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.

117

-

-

... More
od18843/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required.

309

-

-

... More
od18845/2021_2022 : Supply of 380 mm sweep heavy duty exhaust fan indie cast aluminium working on 230 V AC supply complete with all accessories as required.

5

-

-

... More
od18849/2021_2022 : Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,maximum system wattage of 40Watts, lumen output greater than 4000 lumen, power factor 0.9,rated life of L70 @ 50,000 hours, and including all necessary accessories as required complete

36

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

40

-

-

... More
od18793/2021_2022 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall. ,

10

-

-

... More
od18794/2021_2022 : Supply and fixing anodised aluminum glass framed shock treatment chart.,

10

-

-

... More
od18804/2021_2022 : Supply and fixing of First aid box

10

-

-

... More
od18839/2021_2022 : od75491/2019_2020 : Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,20mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound and providing h heavy duty enclosure with cover plate having locking arrangement.

20

-

-

... More
od18842/2021_2022 : Supply and providing ISI marked electrical 3.3 kV grade anti-skid rubber mat(2mx1mx2mm thick ) as per IS:15652

20

-

-

... More
od18847/2021_2022 : Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth,electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.,(Jointing shall be done by overlapping and with 2 sets of brass nut bolt , spring washer spaced at 50mm)

70

-

-

... More
od18848/2021_2022 : Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required.

25

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

780

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

420

-

-

... More
od18853/2021_2022 : Providing and fixing 32 mm X 6 mm G.I. Tape (1.475 kg/mtr) on surface or in recess for connections etc. as required.

100

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

3000

-

-

... More
90.16.1.6 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)

90

-

-

... More
90.16.1.11 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)

1200

-

-

... More
od344484/2021_2022 : Supplying and laying 32mmx6mm GI strip at 0.50 metre below ground as strip,earth,electrode, including connection/ terminating with G.I. nut, bolt, spring,,washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt , spring washer spaced at 50mm)

1600

-

-

... More
LIGHTNING PROTECTIONS

-

-

-

... More
od18783/2021_2022 : Supply and Fixing of 8 mm Aluminum Round Conductor as vertical down conductor with the required mounting clamps , cross connectors, T connectors ,expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on surface as needed.,

630

-

-

... More
od18786/2021_2022 : Supply and Fixing of 8 mm Aluminum Round Conductor as horizontal air terminal with the required mounting clamps , cross connectors, T connectors ,glue, expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on sheet roof,

25

-

-

... More
od18791/2021_2022 : Supply and Fixing of 8 mm Aluminum Round Conductor as horizontal air terminal with the required mounting clamps , cross connectors, T connectors , expansion piece and other accessories required as per IEC 62305-3 and DIN EN 50164-2 suitable for installation on parapet,

550

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

600

-

-

... More
od18803/2021_2022 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip

25

-

-

... More
DG SETS AND ANCILLERIES

-

-

-

... More
od18784/2021_2022 : 30KVA DG SET,Supply, Installation, Testing and Commissioning of outdoor 30kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 30 KVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500RPM, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 , IS: 4722. ,Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank , fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. Rate shall be inclusive of all the civil work including RCC foundation. No extra rate shall be provided for foundations and related civil works. The work should be as per Electrical Inspectorate/ Pollution control board standards.,

2

-

-

... More
Civil items

-

-

-

... More
od21648/2021_2022 : Supply and fixing of chequered plate of 6 mm thick including cutting to required size using gas cutter and lay the same over the trench, fixing of nosing angle and supports for chequered plate, related civil works, finishing etc. and painting with two coats of enamel paint over one coat of Zinchromate primer as required.,

50

-

-

... More
od157302/2021_2022 : Providing, laying and fixing following dia RCC pipe NP 4 class (heavy duty) in,ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2,fine sand) including trenching upto 1.5 m depth and refilling etc. as,required.,300mm dia

50

-

-

... More
UPS & Accesories

-

-

-

... More
od146389/2022_2023 : UPS AND ACCESSORIES,,Supply , Installation, Testing and Commissioning of 1 kVA, single phase input, single phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . ,Fully digital controlled based on DSP,Power factor corrected from end 0.8,Pure sine wave output.,Full time output voltage , frequency regulation,Auto regulation of battery end voltage,Intelligent interface with LED/LCD display,Static bypass switch / manual by pass switch,Auto temperature compensation,

7

-

-

... More
LT PANELS AND ACCESSORIES

-

-

-

... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

290

-

-

... More
90.14.2.2 : Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

6

-

-

... More
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board A' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

115

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

80

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

15000

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

8528.2

-

-

... More
90.14.10.2 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

42

-

-

... More
90.14.10.4 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

4

-

-

... More
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

75

-

-

... More
90.14.11.15 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A

4

-

-

... More
od149575/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.,320A, 36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

2

-

-

... More
od149576/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.,630A, 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

1

-

-

... More
od149724/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.,160A, 25/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

7

-

-

... More
od149725/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.,250A, 36 kA (Ics=100%Icu), 3 pole and neutral link current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

4

-

-

... More
od150147/2022_2023 : Supply, Installation, testing and commissioning of 100A Automatic Transfer Switch (ATS) with Automatic mains failure (AMF) facility confirming to IEC60947-6-1 suitable for 440V 50Hz supply in the existing panel assembly as required.

2

-

-

... More
od150148/2022_2023 : Supply, conveyance and fixing the following types current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.,160A, 25/36 kA (Ics=100%Icu), 3 pole and neutral link current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

10

-

-

... More
od150149/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.,250A, 36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

2

-

-

... More
od150175/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 40A, 4 POLE MCB ISOLATOR

22

-

-

... More
od150176/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 63A, 4 POLE MCB ISOLATOR

6

-

-

... More
od150177/2022_2023 : Supply, conveyance and fixing the following types , current rated control gears , switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 100A, 4 POLE MCCB ISOLATOR

2

-

-

... More
od150410/2022_2023 : Supply and fixing of 3 phase, 4 wire, 0-60A, accuracy class 1 DLMS type base mounted electronic energy meter as per KSEBL standards with appropriate cut out fuse in complete as required.

24

-

-

... More
od150411/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, 500A-630A

1

-

-

... More
od150740/2022_2023 : Supplying and fixing of Resin Cast metering CT 630/5A 15VA accuracy class 1, in existing panel and giving connection complete.

3

-

-

... More
od150741/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - BLUE Colour in the existing panel.

20

-

-

... More
od150742/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, up to 160A

67

-

-

... More
od150743/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, 200A-250A

6

-

-

... More
od150744/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, 320A-400A

2

-

-

... More
od150745/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour in the existing panel.

93

-

-

... More
od150746/2022_2023 : Supply, Installation, testing and commissioning of 40A/32A, 3 Phase AUTOMATIC CHANGE OVER WITH CURRENT LIMITER (ACCL), TPN or SPN (2.5A) settable on DG mode confirming to IEC 60947-6 , 3 suitable for 440V 50Hz supply in the existing panel assembly as required.

22

-

-

... More
od150795/2022_2023 : Supplying and fixing of Resin Cast metering CT 160/5A 15VA accuracy class 1, in existing panel and giving connection complete.

12

-

-

... More
od150796/2022_2023 : Supplying and fixing of Resin Cast metering CT 250/5 A 15VA accuracy class 1, in existing panel and giving connection complete.

6

-

-

... More
od151073/2022_2023 : Supplying and Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade grey colour HFFR insulated stranded single core copper conductor cables 1.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

480

-

-

... More
od151074/2022_2023 : Supplying and Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade grey colour HFFR insulated stranded single core copper conductor cables 2.50 sq. mm single run with required sockets, conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

240

-

-

... More
od151075/2022_2023 : Supply and Fixing of Digital Multifunction meter to read: W, Wh, PF or VA, Vah, PF or V AR, V ,A Rh, PF - 3 phase accuracy class 0.5 LED in the existing Panel as required.

16

-

-

... More
od151076/2022_2023 : Supplying and fixing of SPD Class B+C/Type 1+2, Multi stage protection device should be suitable for TT ,TNS configuration should be pluggable with thermal indication (L-N) have protection in common and transverse mode. The device should be categorized as per IEC61643-11. The SPD should be able to protect against lightning impulse (10/350 μs) and switching surges (8/20 μs). The SPD should have separate plug having MOV on a common base to get protection against lightning and switching surge. The device should be able to discharge safely 7 KA L-N and 25KA N-PE of impulse current (10/350) and should have I max of 60 KA against 8/20.

4

-

-

... More
od151077/2022_2023 : Supplying and fixing of Resin Cast metering CT 100/5A 15VA accuracy class 1, in existing panel and giving connection complete.

12

-

-

... More
od151951/2022_2023 : Supplying and fixing of 2 A SP MCB (C curve), 10 kA breaking capacity in the existing panel for control devices as required in complete.

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.