KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Civil And Construction
Building Construction
Eprocure
Opening Date23 May 2022
Closing DateCancelled
Tender Amount₹ 15,09,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

2

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

1

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

5371.21

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

2024.36

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

3399.74

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

2925.34

-

-

... More
2.10.1.3 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

110

-

-

... More
50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.

4419.98

-

-

... More
od102283/2021_2022 : Filling with contractor own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, with all leads and lift as per direction of site Engineer-in-charge

500.3

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

20.38

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

380.37

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

14.75

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

99.38

-

-

... More
4.13 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

114.49

-

-

... More
50.4.1.1 : Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc.

16.58

-

-

... More
od40837/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth level

428.25

-

-

... More
od40838/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work above plinth level upto floor V level

537.75

-

-

... More
od83894/2021_2022 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.(Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)

6.16

-

-

... More
od84044/2021_2022 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).(Note: Minimum cement content considered in M-30 is @ 400 Kg/cum as per IS 2911 : 2010 ) 500 mm dia piles

2009.1

-

-

... More
od55713/2021_2022 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .Minimum cement content considered in this item is @ 340 kg/cum. All work upto plinth level.

541.9

-

-

... More
od84046/2021_2022 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .Minimum cement content considered in this item is @ 340 kg/cum. All work upto floor V level.

43.24

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

811.61

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

2215.41

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

1369.31

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2702.97

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1738.67

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

779.84

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

893.73

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

262.65

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

2177.68

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

5.05

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

144267.01

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

91308.17

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

597.6

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

28.49

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

160.18

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

427.83

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

195.27

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

5.7

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

50.19

-

-

... More
od40839/2021_2022 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

24.97

-

-

... More
od40840/2021_2022 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half thick solid block masonry.

815.76

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

169.22

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

814.96

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

814.96

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

52.47

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

55.35

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

7

-

-

... More
21.7.1 : Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Anodised aluminium sheet 2.5 mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

682.92

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

1.09

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

49.92

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

40.31

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

15.12

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

176

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

29

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

35

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

35

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

26

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

70

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

58

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

164.2

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

46.32

-

-

... More
9.126.1 : Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm thick.Marine plywood conformingto IS : 710

9.45

-

-

... More
9.127.2 : Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

18.9

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

1

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

58.4

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately)

11.59

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

4.97

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

31.06

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

449.95

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

22

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.

530.52

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

200.08

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

16.86

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1426.05

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

241.04

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

79.55

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

129.2

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

3399.88

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

21.12

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

8

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

34511.07

-

-

... More
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

6

-

-

... More
10.19 : Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

1927.61

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

291.46

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

19257.23

-

-

... More
10.27.2 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm

670

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

4439.2

-

-

... More
12.45.4 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.

89.18

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

9888.1

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

2933.64

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

2576.65

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

940.77

-

-

... More
13.28.2 : 12 mm thick plain cement mortar bands in cement mortar 1:4 ( 1 cement : 4 fine sand) :Sunk Band

76

-

-

... More
13.33.2 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Raised and cut pointing

120

-

-

... More
13.42 : Distempering with 1st quality acrylic distemper (ready mixed) of approvedmanufacturer, of required shade and colour complete, as per manufacturer'sspecification.

761.12

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

8332

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

1299.12

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

3994.17

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

1456.23

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

7192

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

272

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

135.47

-

-

... More
16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

2620

-

-

... More
16.2 : Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density ( proctor density)

589.5

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

30.6

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

545.06

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

655

-

-

... More
16.89 : Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

220

-

-

... More
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

2620

-

-

... More
19.6.4 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia R.C.C. pipe

36

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)Complete as per design

164

-

-

... More
19.36.1 : Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

20

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

844.39

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

2347.67

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

634.99

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

811.9

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

2

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

2

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

2

-

-

... More
30.2.2 : Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

25.32

-

-

... More
30.2.3 : Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

25.32

-

-

... More
30.2.4.1 : Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm

25.32

-

-

... More
30.2.8 : Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

101.26

-

-

... More
30.2.9 : Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

101.26

-

-

... More
30.2.33 : Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

500

-

-

... More
od40834/2021_2022 : Supply and fixing of Double Skin metal Roofing with insulation consisting of profiled colour coated galvalume sheet as top sheet with 975mm cover width, 28mm crest height at 195mm pitch made out of 0.50mm TCT cold rolled steel of 550Mpa yield strength with hot dip metallic coating of minimum 150gm/sqm zinc aluminium alloy coating mass (55% aluminium, 43.5% zinc & 1.5% silicon) total of both sides. The colour shall have a total coating thickness of 35 microns of silicon modified polyester paint system in approved colour comprising of 20 micron exterior coat on top surface and 5 micron reverse coat on back surface over 5 microns primer coat on both surface. The sheet shall be factory cut and supplied in required length to suit site condition and design drawings. The top sheet shall be crest fixed to the GI Z sub girt already provided on the bottom sheet with hot dip galvanized imported self-drilling fasteners with integral EPDM washers for perfect sealing . The bottom sheet shall be reverse profiled colour coated galvalume sheet with 975mm cover width, 28mm crest height at 195mm pitch made out of 0.50mm TCT cold rolled steel of 550Mpa yield strength with hot dip metallic coating of minimum 150 gm/sqm Zinc Aluminium Alloy coating mass (55% Aluminium, 43.5% Zinc and 1.5% Silicon) total of both sides. The colour coating shall have a total coating thickness of 35 micron silicon modified polyester paint system in approved colour comprising of 20 micron of exterior coat on top surface and 5 micron reverse coat on back surface over 5 micron primer coat on both surface. The bottom sheet shall be fixed directly to the purlin as liner sheet using galvanized imported self drilling and self tapping fasteners with EPDM washers. Rockwool Slabs of 50mm thick having a density of 48kg/cum laminated with Aluminium foil on one side shall be sandwiched between the internal and external sheeting as insulation. The sheet shall be separated with Z shaped sub girts of 50 x 50 x 50mm size made out of 1.6mm thick galvanized steel sheets. The sub girts shall be fixed on the bottom sheet and shall be used for supporting the external sheet (top sheet).The rate shall include cost and conveyance of all material, labour charges, lead etc. complete as directed by Engineer - in- charge. (All works covered by this specification shall be carried by an experienced agency having sufficient experiencein this type of roofing system Only skilled and experienced persons shall be employed for this purpose.)

1596

-

-

... More
od40835/2021_2022 : Providing and fixing ridge/ valley capping/flashing in required width (minimum 500 mm) with plain galvalume colour coated sheet made out of 0.5mm TCT, minimum 550 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges, all taxes etc. complete at all levels as directed by Engineer-in-Charge

202

-

-

... More
od40836/2021_2022 : Providing and fixing steel (white power coated) crescent lock for uPVC /aluminum sliding window/ door with necessary screws etc. complete.

93

-

-

... More
od40841/2021_2022 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

164.51

-

-

... More
od40844/2021_2022 : Providing and applying self levelling compound of approved make upto 3mm thick including primer(acrylic based) for the high performance and correction of irregular substratas( low co2 emmission and very low volatile organic compound emission, recyclable) for attaining a levelled surface for epoxy,vinyl, wooden flooring etc with a mixing ratio of 6.5litre of clean water to 25 kg bag using HDE technology with extended flow including cost and conveyance of all materials, labour, curing, lead lift , etc. complete as directed by Engineer-in-Charge at all levels.The above work shall be carried out by an agency having sufficient experience in similar work and only skilled and experienced persons shall be employed for this purpose.

608

-

-

... More
od40845/2021_2022 : Supply and installations of Maple wood sports flooring as per specifications and conditions mentioned below: Hard Maple Surface: \Top surface to consist of a solid, MFMA Certified 2nd and better Grade , Hard Maple strip with minimum dimension of 20mm thickness x 57 mm width x RL (random length). Each individual strip of Hard Maple shall include the certification chop of the MFMA (Maple Flooring and Manufacturers Association) and manufacturing mill certification number. System must provide a solid Hard Maple top layer of (minimum thickness) 20mm and is to be machined to a smooth finish and varnished after fixing of the individual boards in place at the installation site. Pre-finishing of the boards at the factory is not acceptable. 25 years warranty for the flooring. Maple Fasteners: Hard Maple boards to be fastened in place by pneumatic machine stapling with a 50mm coated flooring staple. Boards to be secret fastened with the staple applied at a 45 degree angle at the top of the tongue on the side of the board. Vapor Barrier: .20mm polyethylene membrane installed over the concrete base, beneath the flooring system as a vapor barrier between the concrete and wood floor. Plywood subfloor and resilient pads: 1st layer of plywood to be 12mm x 1220mm x 2440mm MR Grade ISI Mark plywood. 1st layer of plywood to have the resilient pads affixed to the underside on 30 cm o.c. spacing regiment and to be installed on the concrete with the long dimension of the plywood running at a 90 degree angle to the direction of the hardwood strip flooring 2nd layer of plywood to be 12mm x 1220mm x2440mm MR Grade plywood and fixed to the 1st layer with mechanical fasteners (staples) at a direction in 45 degree angle to the 1st layer Shock Pads: Resilient pads of 19mm thick 2 stage, Polyurethane, resilient shock pads fixed to the underside of the 1st layer of plywood at 30cm o.c. spacing regiment. System must provide a minimum of 10 resilient pads per square meter of installed flooring system Shock Pads Tensile Strength should not be less than 5000 psi and must be tested in accordance with STEM Finishing :Floors to be machine sanded with drumsamder ( coarse grade 60grit) sandpaper to make the floor smooth and non-slippery. The floor shall not be sealed. Apply 2 coat of Approved sealer and 2 coat of Gym finish per manufacturer's instructions with 2 coat of game line& marking. Performance and Quality Certification: 1. Flooring system shall be independently tested and certified to the EN14904 performance standard and certificate from an accredited, independent testing laboratory must be submitted 2. Manufacturer to be a certified manufacturer of the MFMA (Maple Flooring Manufacturers Association)-certificate to be provided as evidence of such . Manufacturer to be certified in accordance with ISO9001:2000 standard- ISO certificate to be provided as evidence of such. 3. Flooring system to be tested and certified in accordance with STEM (Structural Testing and Engineering Measures)- certificate to be provided as evidence of such. 4. Shock Pads :Tensile Strength should not be less than 5000 psi and must be tested in accordance with STEM testing standards and provide minimum ratings certificate to be provided as evidence of such. 5. The floor manufacturer should have Certifications from following International federations 1. WORLD BADMINTON FEDERATION. 2. INTERNATIONAL HAND BALL FEDERATION.(IHB) 3.INTERNATIONAL BASKET BALL FEDERATION(FIBA)

608

-

-

... More
od40848/2021_2022 : Providing and fixing glazing with 12mm toughened glass in existing aluminium frame work with EPDM rubber / neoprene gasket.The joints between glass panels and gaps at the perimeter of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof etc. complete as per the architectural drawings and the directions of Engineer-in-charge.

52.08

-

-

... More
od40849/2021_2022 : Supplying And Fixing BTS 75 or equivalent Floor spring ,Top patch , bottom patch , Top pivot , and corner lock for Frameless glass door with 60mm EPC - both side key , all complete as per approved drawings and as directed by Engineer in charge

7

-

-

... More
od40850/2021_2022 : Supply and Installation of Handles TGDIH 450 X 25 for Glass Door of Stainless Steel Satin Finish, SS 304 Back To Back Pull Handles Dia. 25 mm,CTC Length 350 mm all complete, as per approved drawing and as directed by Engineer in charge.

7

-

-

... More
od40851/2021_2022 : Providing and fixing Heradesign Superfine, 1 layer magnesite bonded wood wool acoustic panel, 1mm thick fibre, exquisite surface structure, building biology recommended, size 1200 x 600x 25mm, having edge detail AK-01 (5mm bevel on all 4 sides), weight 11.30 Kg/Sqm, fire protection class Bs1, d0 as per EN 13501-1 and Humidity Resistance of 95%. Thickness Tolerance T2 (+ or - 1 mm) according to EN 13168. Wood wool panels to be PEFC certified and should bear the Forest Stewardship Council Seal confirming that the wood used originates from responsibly managed forests. UD profile 28mm/27mm/0.60mm is fixed to the wall, such that the base of the UD profile is 25mm above the planned finished ceiling level / 25mm less that the finished wall level. The ends of the CD profile is to be incerted into the UD profile and placed at a distance of 600mm centre to centre and is to be secured to the soffit/wall using the Heradesign Universal Bracket. The Universal brackets are to be fixed to the soffit/wall at a distance of 900mm using 6mm dia anchor fasteners (for ceilings) and wall screws (for walls). Wood wool boards to be screw fixed to the CD profile using 6 screws (per board) 50/4.50mm dia Heradesign screws. The wood wool board should be backed by 40mm thick glass wool slabs packed in 1200 x 600mm polythene bags having a gross density of 50kg/m3. The finished face of wood wool panels have to be installed at a distance of 300mm from the soffit to achieve a NRC of 0.90 as per ASTM C423. Panels can be spray painted on site (before installation) under supervision of manufacturer. Making the cut outs for HVAC grills/diffusers/serviceaccess doors, electrical appliances etc. wherever necessary. The Samples of the panel shall besubmitted to the engineer-in charge for approval.

410.94

-

-

... More
od40852/2021_2022 : Supply and installation of Indoor movable sports equipment for basketball, volleyball and badminton courts 1. 3 set of movable Badminton Mobile Posts with counter weight and net for 3 badminton courts. 2. 1 pair of International Standard Rolable Foldable Basketball Goal Post with transparent acrylic back board, 3 side padding and Dunk Ring with hydraulic system, frame and markings as per FIBA Standards, Two Basket rings with a ring mounting plate and net complete for one basketball court. 3. 2 pair of International Standard Heavy duty Volleyball poles with 100mm Aluminum pipe Sliding for adjustable Height, Ratchet system with Pulleys fixing accessories with net complete for two volleyball courts. The rate shall be inclusive of all materials, transportation and labour charges for installing the equipment with all accessories and necessary / ancillary works. So as to satisfy the respective FIVB/FIBA standards. The work to be executed as per the directions of the engineer-in-charge.

1

-

-

... More
od55275/2021_2022 : Providing and fixing Hera design Superfine, 1 layer magnesite bonded wood wool acoustic panel, 1mm thick fibre, exquisite surface structure, building biology recommended, size 600 x 1200 x 25mm, having edge detail SK-04, weight 11.30Kg/Sqm, fire protection class B-s1,d0 as per EN 13501-1 and Humidity Resistance of 95%. Thickness Tolerance T2 (+ or - 1 mm) according to EN 13168. Wood wool panels to be PEFC certified and should bear the Forest Stewardship Council Seal confirming that the wood used originates from responsibly managed forests. The wood wool panels to be laid in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @ 90 gsm/sqm) consisting of Main "Tee" size 24W x 38H x 3600L mm made from 0.30 mm thick sheet spaced at 600mm centre to centre and Cross "Tee" size 24W x 38H x 600L mm made of 0.30 mm thick sheet to be interlocked between the main T runners at the distance of 1200mm centre to centre to creaate 1200x600mm module to lay ceiling tiles of approved surface pattern in the grid including, wherever required, cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. The perimeter trims to be of 24W x 24H x 3600L mm and 0.30 mm thick. Main "Tees" to be suspended from ceiling using onsisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia - 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners.. The first suspension from the perimeter trim should not exceed 300mm. The bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint. The wood wool board should be backed by 40mm thick rock wool slabs packed in 600 x 600 polythene bags having a gross density of 50kg/m3. The finished face of wood wool panels have to be installed at a distance of 300mm from the soffit to achieve a NRC of 0.90 as per ASTM C423. Panels can be spray painted on site under supervision of manufacturer.

1267.8

-

-

... More
od55323/2021_2022 : Providing and fixing of 10mm Clear toughened glass Slimline Partition system with slim profiles includes OZ-DP-PR-11 or equivalent fixed profile and OZ-AL-DP1 or equivalent door profile. Door lock will be having one side key and other side Knob operation (OZ-DP1/2- GDL or equivalent ). 2 nos of frame front facing mounted type hinges (OGC-DH-1STD or equivalent ) used for door. Hydraulically controlled door closer (NSK-980 TA SSS or equivalent ) will be used for door operation. 10mm clear toughened glass of approved make will be used for partition and door. The rate shall be inclusive of cost of all materials, transportation, loading - unloading charges, Scaffolding, lead, lift, labour charges etc complete, as specified by the Engineer-In-Charge

22.8

-

-

... More
od55714/2021_2022 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

740

-

-

... More
od55776/2021_2022 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

19

-

-

... More
od55778/2021_2022 : Providing and fixing Starting Block with FINA Standard used for international events.The rate to be inclusive of all transportation from manufacturing plant to site, equipment and consumables, line marking, certification by FINA complete as per FINA specifications.

5

-

-

... More
od55779/2021_2022 : Providing and fixing Racing lane of 25m maxi model consisting of 25m stainless steel cable, stainless steel hook, super Tensioned and Antiwave float as FINA standard and approved make of colour and polyester line. The rate to be inclusive of all transportation from manufacturing plant to site, equipment and consumables, line marking, certification by FINA complete as per FINA specifications.

6

-

-

... More
od83385/2021_2022 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Routine test (Test Load 1.5 times the Safe capacity =1.5X136 T = 204 T )

1

-

-

... More
od83386/2021_2022 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification and the direction of Engineer - in - Charge. Initial test ( Test Load 2.5 times the Safe capacity=2.5X136 T=340 Tonne capacity )

2

-

-

... More
od84190/2021_2022 : Soling with soling stone of size 150 to 75 mm brokenstone and blinding materials, including hand packing and wedging them tightly so that the whole is formed as a solid mass, spreading blinding material in 12mm thick layers and sweeping the same to fill the voids,watering profusely and consolidating with hand rammer/ plate vibrator etc complete as per the direction of Engineer-in - Charge.

113.42

-

-

... More
od84191/2021_2022 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge. Excavated Earth/rock.

1087

-

-

... More
od84402/2021_2022 : Supplying river sand brought from outside including transportation,loading, unloading ,taxes etc complete as directed by the Engineer- in- charge

25.32

-

-

... More
od84403/2021_2022 : Supplying and planting healthy plants of Nerium oleander (kaner) dwarf of height 30-40 cm. in earthen pot of size 20 cm of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.

23

-

-

... More
od84404/2021_2022 : Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v

6

-

-

... More
od84405/2021_2022 : Supply and stacking of Terminalia arjuna plant of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

6

-

-

... More
od84408/2021_2022 : Providing and laying of 20mm downgraded metal (Coarse rubble granite Stone) of approved quality as filter media around the drainage pipes in the sides of trench as per the directions of Engineer-in-charge. Rate inclusive of all materials,transportation and labour charges complete.The work has to be executed as per detailed specifications , and or as approved by Engineer -in -charge

57.6

-

-

... More
od84409/2021_2022 : PVC WEEP HOLES- Providing weep holes using 50mm dia. PVC pipes working pressure 6kg /sq.cm and covering ends with nylon mesh including cost of materials, conveyance, labour charges etc. complete.

192

-

-

... More
od102438/2021_2022 : Providing and fixing swimming pool tiles at finished plain wall/floor surface of size 247 mm x 122 mm of approved thickness as per manufacturer specification in all colour, design, fixing in customize design as per direction of Engineer-in-charge. The tiles to be fixed on the wall/floor surface with the help of approved adhesive applied at the rate recommended by manufacturer with 3mm spacer joints .The spacer joints 3mm shall be grouted using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) or as per the recommendation of manufacturer, including finishing complete as per direction of Engineer-in-charge .The rate is inclusive of all labour , materials ,lead,lift etc complete at all levels as directed by Engineer-in-charge.

452.25

-

-

... More
od119717/2021_2022 : Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood: 35 mm thick shutters

49.92

-

-

... More
13.45.1 : Finishing walls with textured exterior paint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

143.34

-

-

... More
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade

351

-

-

... More
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe

20

-

-

... More
19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

10

-

-

... More
od84047/2021_2022 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
od140474/2021_2022 : Supply and fixing SS 304 grade Body Wheel Double of following specifications including AMC for 3 years 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1000 x 600 x 1700 mm 8.Weight: 50 kg

1

-

-

... More
od140475/2021_2022 : Supply and fixing SS 304 grade Air walker-Single of following specifications including AMC for 3 years 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1100 x 350 x 1300 mm 8.Weight: 52 kg

1

-

-

... More
od140476/2021_2022 : Supply and fixing SS 304 grade Elliptical Trainer of following specifications including AMC for 3 years 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1100 x 520 x 1600 mm 8.Weight: 40 kg

1

-

-

... More
od140477/2021_2022 : Supply and fixing SS 304 grade Waist Twister - Double of following specifications including AMC for 3 years 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1250 x 450 x 1300 mm 8.Weight: 45 kg

1

-

-

... More
od140478/2021_2022 : Supply and fixing SS 304 grade Sit-Up Board of following specifications including AMC for 3 years. 1.Main Tube shall be Minimum 50mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1400 x 450 x 1000 mm 8.Weight: 35 kg

1

-

-

... More
od140479/2021_2022 : Supply and fixing SS 304 grade Parallel Bar of following specifications including AMC for 3 years. 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1600 x 640 x 1300 mm 8.Weight: 48 kg

1

-

-

... More
od140480/2021_2022 : Supply and fixing SS 304 grade Surf Board - Double of following specifications including AMC for 3 years. 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1450 x 700 x 1300 mm 8.Weight: 44 kg

1

-

-

... More
od140481/2021_2022 : Supply and fixing SS 304 grade Leg Press - Single of following specifications including AMC for 3 years. 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1000 x 500 x 1700 mm 8.Weight: 49 kg

1

-

-

... More
od140482/2021_2022 : Supply and fixing SS 304 grade Pull Down – Single of following specifications including AMC for 3 years. 1.Main Tube shall be Minimum 75mm Dia x 2.5mm thick 2.Auxiliary pipes shall be 2.5mm thickness 3.Sealed Bearings (Self lubricated) shall be used. 4.Base Cover SS of 270mm dia. 5.Fasteners shall be of Stainless Steel Material. 6.Pipe covers shall be of Corossion Resistance - Stainless Steel / Aluminium / Rubbers 7.Dimensions: 1000 x 630 x 1700 mm 8.Weight: 55 kg

1

-

-

... More
od185591/2019_2020 : Supplying ,stacking and laying of brick bats and sand (over the brick bats) to cover the voids between brick bats including watering and rolling using a medium size roller, cost of all materials, labour, lead, lift, hire charges etc complete and as directed by Engineer-in-charge.

35.28

-

-

... More
od185592/2019_2020 : Supplying and spreading cow dung in liquid form over the play ground made of earth, manure(cow dung) and sawdust to form standard kabadi court including cost of all materials, labour, lead, lift, hire charges etc complete and as directed by Engineer-in-charge.

14.7

-

-

... More
od185593/2019_2020 : Supplying and filling available excavated earth (silt) excluding rock/stones othe impurities, over areas including watering and rolling using a medium size roller including cost of all materials, labour, lead, lift, hire charges etc complete and as directed by Engineer-in-charge.

29.4

-

-

... More
od185594/2019_2020 : Supplying and laying over areas , a mixture of available sieved excavated earth (silty) excluding rocky particles or other impurities, smooth sand and saw dust , including thoroughly mixing in required proportions, watering and rolling using a medium size roller including cost of all materials, labour, lead, lift, hire charges etc complete and as directed by Engineer-in-charge.

34.69

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

116.6

-

-

... More
od84825/2021_2022 : Providing and constructing soak pit 1.5 m x 1.5 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

1

-

-

... More
od84830/2021_2022 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

1

-

-

... More
od100686/2021_2022 : Providing and constructing soak pit 1.5 m x 1.5 m x 1.5 m size with honey comb brick work on the sides upto a height of 0.9m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.2 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

1

-

-

... More
18.12.7 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 65 mm dia nominal bore

100

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal bore Horizontal

2

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal bore Horizontal

2

-

-

... More
23.1.1.1 : Boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools plants & machineries required for the job, all complete as per direction of Engineer - in- Charge, upto 90 metre depth below ground level.All types of soil300 mm dia

80

-

-

... More
23.3.2 : Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge.150 mm nominal size dia

20

-

-

... More
23.8 : Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine /medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in- charge.

0.39

-

-

... More
23.12 : Development of tube well in accordance with IS: 2800 (Part I) and IS : 1189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc.by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer - in-charge.

10

-

-

... More
23.13.2 : Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia

2

-

-

... More
23.14.2 : Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tubewell as per IS : 2800 ( part I), including ecessary bolts & nuts of required size complete.150 mm clamp

2

-

-

... More
23.15.2 : Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (part I).150 mm dia

2

-

-

... More
od100710/2021_2022 : Supplying and filling the proposed yard with 40 mm size blue jelly of 150 mm thick including cost and conveyance of all materials, labour charges etc. complete.

6

-

-

... More
od100782/2021_2022 : Providing and fixing 1.8 meter high chain link fencing over 600 mm high random rubble masonry as per drawing and specification, using 4 mm thick PVC coated chain link with a framework of 50x50x6 mm MS angle between vertical posts of ISMC 75 mm at 2400 mm interval, which are fixed to the concrete footing (1:2:4) of size 450x450x200 mm (above GL) with adequate footing depth, between the RR masonry. RR masonry (450 mm thick) and 200 mm from ground level for foundation and plinth in cement mortar (1:6). The random rubble masonry is to be pointed using cement mortar 1:3 to have a flush finish. Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS frame work for chain link fencing is finished using zinc chromate primer and 2 coats of synthetic enamel paint. A 1.5 meter wide gate shall be provided with suitable locking arrangements. The rate shall be inclusive of all materials, labour, lead, lift, etc including excavation works and fabrication and assembly works including all nuts, bolts and other miscellaneous items, etc. all complete as per drawing

20

-

-

... More
od120229/2021_2022 : Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia

50

-

-

... More
od188219/2019_2020 : Providing and fixing of 65 mm diameter GI C class pipe threaded (IS 1239 heavy class) as borewell discharge pipe line complete with GI fittings, flanges, clamps and all accessories as required inside borewell/tubewell.

60

-

-

... More
od188220/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels . 40mm dia

2

-

-

... More
od188221/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50mm dia

2

-

-

... More
Water Supply and Sanitary Arrangements

-

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

3

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

2

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

5

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

5

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

5

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

1

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

1

-

-

... More
18.31.1.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II

1

-

-

... More
18.31.3.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):150 mm diameterClass II

1

-

-

... More
od42461/2021_2022 : Providing and fixing premium quality C.P. brass overhead shower and wall flange of approved make and model including cost of all materials, labour etc., complete as directed by the Engineer -in- Charge at all levels.(Hindware F160039+F200008/ Cera F7040104+F7020304+F2006351+F4050502 or equivalent)

4

-

-

... More
od185607/2019_2020 : Providing & fixing star white vitreous china flat back urinal with CP brass flush valve auto closing system with built in control cock and wall flange of approved size with all accessories to provide satisfactory functioning including cost and conveyance of all materials, labour charges ,lead, lift necessary wall cutting / chasing and making good the walls, floors, slab, as required for urinal flushing etc. complete, testing and commissioning to the satisfaction of Engineer in charge at all levels.(Model: Cera S4020112+F9020201 / Hindware 60002+F860046 or equivalent).

12

-

-

... More
od185608/2019_2020 : Supplying and fixing approved quality white vitreous china urinal division plate including cost and conveyance of all material, labour charge, lead, lift, etc. complete as directed by the Engineer-in-Charge. Models- Hindware 61001/ Cera S4090101 or equivalent

12

-

-

... More
od185609/2019_2020 : Providing and fixing star white vitreous china under counter wash basin of approved size & make including one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap, 15mm angle valve, etc. complete as directed by the Engineer-in-charge at all levels. Models- Wash Basin: Cera S2030103/ Hindware 10065 + Cera F2006104/ Hindware F360001 or equivalent

20

-

-

... More
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps

2

-

-

... More
17.22A : Providing and fixing CP Brass 32mm size Bottle trap of approved quality & make and as per the direction of Engineer in charge.

2

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

4

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

4

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

25

-

-

... More
od185610/2019_2020 : Providing and fixing frameless mirror, with all four edges machine polished and back side protected with safety film and 4 mm thick Plywood backing and fixed on walls with mirror screws. The rate includes lifting, cutting etc. as per design and drawing.

12.1

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

66

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

115

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

70

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

12

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

12

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

22

-

-

... More
od42453/2021_2022 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings & specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 150 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

136

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

2

-

-

... More
od42433/2021_2022 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame (medium duty) : With bricks.Class designation 75

18

-

-

... More
od185612/2019_2020 : Supplying approved make PVC gully trap of size 160x110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size (inside) the weight of cover to be not less than 4.5kg and frame to be not less than 2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm, 115 thick brick wall in CM 1:6 on a foundation of PCC 1:4:8. 100mm thick plastering inside with CM 1:3, 12mm thick with a neat cement flushing coat and conveying to site, cleaning, installing and testing approved make PVC gully trap with 160mm outlet (fabricated), surrounding with CC 1:1.5:3, 150x150mmm, top with CI grating above the PVC gully trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in-Charge.

13

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

2

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

2

-

-

... More
od185613/2019_2020 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 150 mm dia RCC pipes.

30

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

30

-

-

... More
od185614/2019_2020 : Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-charge

11

-

-

... More
od42437/2021_2022 : Providing and fixing floor trap 110 mm dia (gratings exposed)with cockroach trap (multi trap), S304 grade exposed floor grating with multitrap including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

35

-

-

... More
od42438/2021_2022 : Providing and fixing floor trap 110 mm dia (gratings concealed)with cockroach trap (multi trap), S304 grade concealed floor grating with multitrap including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

4

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

500

-

-

... More
od185616/2019_2020 : Providing and fixing 80mm dia GI Vent Cowl for complete as per directions from Engineer in Charge

8

-

-

... More
od185617/2019_2020 : Providing and fixing enclosed type water meter (bulk type) 50mm dia conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge

1

-

-

... More
od41077/2021_2022 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer

6

-

-

... More
od40823/2021_2022 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 65mm 'Y' type strainer

2

-

-

... More
od185619/2019_2020 : Providing and fixing C.I. basket type dirt box strainer 50mm dia for bulk type water meter with nuts, bolts, rubber etc. complete conforming to IS : 2373 : including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge

1

-

-

... More
od185623/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. : 100 mm

2

-

-

... More
od185624/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. 80mm Dia

1

-

-

... More
od185625/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. 65mm Dia

9

-

-

... More
od185626/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge.150mm Dia

5

-

-

... More
od185627/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 200mm dia

4

-

-

... More
od185628/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge. 150mm Dia

1

-

-

... More
od185629/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge. 100mm Dia

6

-

-

... More
od185630/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge. 80mm Dia

4

-

-

... More
od185633/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels 75mm dia

6

-

-

... More
od185634/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels 110mm dia

7

-

-

... More
od185635/2019_2020 : Supplying ,fixing, testing and commissioning of portable drainage pump with 12mm solid handling, with stainless steel construction, stainless steel impeller complete with motor , with carrying handle and all accessories and working with 415V, 3ph and 50 Hz frequency. Capacity:10m3/hour,Head-15m

2

-

-

... More
od185637/2019_2020 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels. Capacity: 15-6.5 m3/hr, Head: 24 -36m

4

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

4

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

4

-

-

... More
od185641/2019_2020 : >Supplying and fixing of activated carbon filter of 800 mm dia x 1500 mm height, comprising of: Vertical ,welded mild steel pressure vessel complete with dished ends and internally coated with epoxy paint. The vessel complete with manhole and cover shall be painted externally with bituminous paint. Rate to be inclusive of set of internals for the above comprising of raw water distributor and filter water collecting system, set of frontal pipe work of mild steel construction complete with vent piping, set of mutually operated multiport valves, set of inlet and outlet pressure guages, etc complete including cost and conveyance of all materials,labour charges,lead ,lift etc as directed by the Engineer in charge at all levels Capacity:5 m3/hour

1

-

-

... More
od185642/2019_2020 : Supplying and fixing of pressure sand filter of 600 mm dia x 1200 mm height,comprising of Vertical ,welded mild steel pressure vessel complete with dished ends and internally coated with epoxy paint. The vessel complete with manhole and cover painted externally with bituminous paint. Rate inclusive of set of mutually operated multiport valves, set of internals for the above comprising of raw water distributor and filter water collecting system, set of frontal pipe work of MS construction complete with vent piping, set of inlet and outlet pressure guages, set of inlet and outlet sample valves etc complete including cost and conveyance of all materials,labour charges,lead, lift etc as directed by the Engineer in charge at all levels.Capacity- 5 m3/hr

1

-

-

... More
od43837/2021_2022 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure gauge and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels .Capacity:5 m3/h Head: 35m

2

-

-

... More
od43838/2021_2022 : Supplying and fixing of electronic diaphragm type dosing pump with all wetted parts in PVC construction suitable for pumping HoCl solution including cost of valve, suction and delivery lines using heavy duty PVC tubes, HDPE tank of 80 litres capacity etc. and complete with all accessories as directed by the Engineer- in -Charge. Capacity : 12 lph @ 3.5 kg/cm2

2

-

-

... More
od185644/2019_2020 : Providing and fixing CP robe hook etc complete testing and commissioning to the satisfaction of Engineer in Charge at all levels.(Models Jaquar ACN 1161N or equivalent)

25

-

-

... More
od185645/2019_2020 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 8931 20 mm nominal bore(Models:Jaquar cat no:FUS-29083K+ALD 089CQT or equivalent)

4

-

-

... More
2.10.1.3 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

30

-

-

... More
od185648/2019_2020 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 300 mm dia RCC pipes.

30

-

-

... More
od185651/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length as per the direction of Engineer in charge 65mm dia

4

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

250

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

205

-

-

... More
od185652/2019_2020 : Providing and fixing PVC pipes including all fittings, jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 200 mm dia 6 Kgf/cm2

253

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

23

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

8

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

12

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

64

-

-

... More
18.9.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes

10

-

-

... More
18.9.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes

32

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

75

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

271

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

161

-

-

... More
18.9.8 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work75 mm nominal inner dia pipes

74

-

-

... More
18.9.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work100 mm nominal inner dia pipes

6

-

-

... More
18.9.10 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work150 mm nominal inner dia pipes

6

-

-

... More
17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

20

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

20

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

21

-

-

... More
od185654/2019_2020 : Providing and fixing sanitary fixtures for handicapped toilet including one wash basin of size 65 x 35cm, one pair mounting brackets, one number pillar cock & all other related fittings like bottle trap, angle cock, waste coupling etc, one number EWC & Cistern complete with fittings & seat cover, one no. hinged rail 76cm & 5 nos. of grab rails 60cm etc, designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as directed by Engineer-in-Charge.Hindware 70002+F360001/ Cera Cruse Set+F2006104 or equivalent

1

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

6

-

-

... More
19.7.2.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5

2

-

-

... More
od185657/2019_2020 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

2

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

12

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

105

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

200

-

-

... More
od41026/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm nominal outer dia pipes

12

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.5

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.5

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.5

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

2

-

-

... More
18.9.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal outer dia pipes

114

-

-

... More
od41027/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 150 mm nominal inner dia Pipes

122

-

-

... More
od187044/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall 100mm nominal dia

20

-

-

... More
od187045/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 80 mm nominal dia pipes

20

-

-

... More
od187046/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 65 mm nominal dia pipes

6

-

-

... More
HT EQUIPMENTS

-

-

-

... More
od186090/2019_2020 : HT Metering Panel with Load Break Switch Supply, installation, testing and commissioning of HT metering Panel with 630A Load Break Switch with HT fuse and Earth switch, Bidirectional TOD meter (with RS485 communication facility), CTs(0.2S) and PT(0.2) , HT fuses, test terminal block, control fuses, etc. The Panel shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54 with canopy, weather proof, undergone seven tank process with powder coated finish. The Panel should have seal Off bushings, space Heater with thermostat, 630A Aluminium busbars and support insulators, provision for earthing, all mounting accessories as required complete as per the requirement of Kerala State Electricity Board. The metering cubicle shall have glass window for meter reading.

1

-

-

... More
od100575/2021_2022 : Supply, Installation testing and commissioning of 11 kV 11 m DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x50mm and supporting structure for 11 kV components with 65x65x6 mm MS angle bracings between consumer and supplier structure,cross arms, 11 kV pin,disc insulators and stay insulators, stay wire, supports, jumpering / interconnecting conductors with '0'SWG Cu, anticlimbig arrangement using barbed wire,earthing etc. on a suitable concrete foundation including the cost of foundation.The DP structure shall consists of the following (Note:All the MS items shall be hot dip galvanised)(Note:The work shall be as per KSEI & KSEB standards) 11 kV, 400A , single brake,TP, gang operated AB switch with operating handle & locking mechanism - 1 No 11 kV Lighting Arrestor -1 set of 3 Nos 11 kV DO fuses-1 set of 3 Nos .The DP structure shall be with all necessary accessories for connecting 11kV cable .

1

-

-

... More
TRANSFORMER

-

-

-

... More
od186069/2019_2020 : 160 KVA 11KV OUTDOOR USS Supply, Installation, Testing and commissioning of 160 KVA Outdoor Unitised Substation consist of 11 / 0.433KV, 160 KVA, 3 Phase, Dyn11, AN, Dry type, Class F Insulated, Cast Resin transformer with enclosure suitable for Outdoor application and 11 KV, 630A, 26.2kA Load Break Switch Panel with all other accessories as specified below 11KV, 26.2kA, 630A Load Break Switch with shunt trip and earth switch- 1 No HT HRC Fuses Seal Off Bushings 1 Set Shunt Trip coil - 230 V AC 1 Set Front operated spring assisted manual closing mechanism, mechanical interlock between incomers, operating handle, 2 NO+2NC Aux. contact etc 160 kVA, 11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer, copper wound, Class F insulation, outdoor distribution Transformer with winding temperature alarm and trip on transformer compartment. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 45/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel as per SLD ON-OFF push button, RYB indicating lamps, Trip push button-1 set Space Heater with Thermostat- 1 set Cubicle Illumination Lamp with Door limits switch-1 set 630 A aluminium busbars for linking to transformer HT side with necessary support insulators-1set Cable boxes for receiving incoming & outgoing cables through Bottom entry & Additional neutral bushings on LV for earthing. 250A FP ,25kA Thermal based MCCB in LT side Earth fault relay (51G) with neutral CT - 1No. The USS shall be totally enclosed, free standing, floor mounting, outdoor type, made of 14SWG sheet steel powder coated with necessary cable & busbar chamber. Rate shall be inclusive of transportation, insurance, lift, lead and all other associated works as required complete Fittings: Standard fittings as per IS:2026/77 and IS as per IS 11171 : 1985. USS enclosure shall be provided an epoxy coating for making it suitable for marine atmosphere

1

-

-

... More
DG SET AND ACCESORIES

-

-

-

... More
od186070/2019_2020 : 160 KVA DG Supply, Installation, Testing and Commissioning of 160 kVA prime rated outdoor D.G Set with acoustic enclosure and Control panel ,protection and digital metering, controls and interlocks, CTs and transducers for all metering and protection and suitable breaker etc. , including antivibration mountings, exhaust silencer and exhaust pipe (including necessary supports)conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 160 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
LT PANEL AND UPS

-

-

-

... More
od186999/2019_2020 : ODP -1 Supply ,Installation, testing & Commisioning of Outdoor Lighting Panel (ODP) cubicle type, made out of Thermoplastic UV resistant enclosure, totally enclosed, IP65, free standing, pedestal mounted with suitable foundation, dust and vermin proof, powder coated, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessary internal wiring ,suitable spreader etc. Panel shall be with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. Incomer:63 A, FP, 25kA, MCCB with adjustable thermal magnetic release with OL & SC protection - 1 No BUSBAR 63A TPN busbars of high conductivity electrolytic quality copper alloy INSTRUMENTS Surge protection device -Type1+2 (0-63)A ammeter Acc. class 1 with 90 deg defl. scale - 3Nos 4A, C curve SP MCB - 3 Nos. (0-500V) Voltmeter with selector switch-1 set RYB indication lamp, LED type - 1 Set OUTGOINGS 25 A, FP RCCB (100mA)-10Nos 25 A C Curve FP MCB-10 Nos

1

-

-

... More
od186079/2019_2020 : 35kVAR APFC PANEL Supply, Installation, Testing & Commissioning of Capacitor Panel Board , cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc., including provision for capacitor mounted inside the panel with adequate number of louvers and powder coated with approved shade and having following specific components all inter connections and following components as per drawing and technical specifications. The panel shall be of Form 3b construction. Incomer 100 A,25kA FP MCCB with adjustable thermal magnetic release with OL & SC protection - 1 no. Instruments 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches, Indication Lamps, CTs, Protection Relays as per SLD . Busbar 100A TPN busbar chamber with Aluminium busbar. Outgoing 32A, 25kA, TP MCCB with adjustable thermal magnetic release with OL & SC protection -5 nos 5 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 1 Nos 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 3 Nos 5 kVAr,480 V,50 Hz capacitor(APP) with 7 % Seriesreactor - 1 Nos 10 kVAr,480 V,50 Hz capacitor(APP) with 7 % Series reactor -3 Nos Control wiring required for no load compensation capacitor

1

-

-

... More
od186097/2019_2020 : MSB PANEL INDOOR Supply, Installation, Testing & Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc. .The panel shall be lockable type as per requirements of EB. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be of Form 4 Construction. Incomer -1 250A,FP 25kA MCCB with thermal based adjustable release with OL & SC protection and shunt trip -1 Nos. Incomer -2 250A,FP 25kA MCCB with thermal based adjustable release with OL & SC protection -1 Nos. 250A FP ATS with AMF relay-1Nos Instruments 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches, Multifunction Meters Indication Lamps, CTs, Protection Relays including IPFC relay-As per SLD Busbar TPN busbar chamber with Aluminium busbar suitable for 250 A Out goings 100A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL & SC protection - 4 Nos 63A, TP+NL, 25kA, MCCB with Thermal Magnetic based release with OL & SC protection -4 Nos 160A TPN MCCB Isolator- 1No SPD type 1

1

-

-

... More
od186115/2019_2020 : Main Fire Pump Panel Supply of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised form 4 construction, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with bus bars extendable on both sides, including all the necessary internal wiring , suitable spreader etc. The panel shall be fabricated from a firm having CPRI certification with test certificates (required for short circuit rating, temperature rise test and IP classification) with following switchgears, metering instruments and accessories etc.complete in all respect as per drawing and technical specification. The panel shall be with top entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram. INCOMER: 160A, FP SDU - 1 No. INSTRUMENTS: (0 to 500 )V analogue type Voltmeter for 3 phase, 4 wire operation with selector switch-1nos Analogue type ammeter (0-160A) for 3 phase, 4 wire operation -3nos Phase indicating lamps LED type RYB - 1 set ON, OFF LED indicating lamps-1set 4A control SP MCB -3nos 160/5A, Class 1.0, 15VA, Cast Resin CT for metering - 3nos BUSBARS:160 Amp TPN bus bars of high conductivity electrolytic quality Aluminium alloy. OUTGOING: 25A DP MCB-1 No for battery charger 125A TP SDU- 1 No. for electric main pump, Star Delta starter of suitable rating for 415V, 50Hz, 3 phase for main electrical fire pump(60 HP) with kW in accordance with the main electric pump. The starter shall have ON, OFF push button, ON, OFF indication lamp complete with all accessories and internal wiring required for automatic and manual operation as required. - 1 No's 40A, TP, SDU - 1 No. for jockey pump , Star Delta starter of suitable rating for 415V, 50Hz, 3 phase Jockey pump (12.5 HP). The starter shall have ON, OFF push button, ON, OFF, LED indication lamp, single phase preventer, complete with all accessories and internal wiring required for automatic and manual operation - 1 No SPARE: 125A, TP, SDU- 1 No. 40A, TP, SDU - 1 Nos. DC Power supply/Battery Charger suitable for 12 V / 24 V DC with boost and trickle selector switch, 0 -15 V / 0 - 30 V DC volt meter, 0 - 20 A DC Ammeter - 1 No. The battery charger/power supply unit should be suitable for charging the Diesel engine starting batteries and Panel Control power backup batteries(2x12V 26Ah) The panel includes 2nos of 12v 26Ah SMF battery for power backup of panel control circuit, 6 panel annunciation window for fault indication with hooter, accept & reset push button, etc. The system shall include all accessories to control the operation of main electric pumps, diesel engine pumps, jockey pumps as per the operating sequence for the fire fighting system indicated in the technical specification. The battery charger and all its components should be housed inside the main fire pump panel. The panel shall be painted with approved colour.

1

-

-

... More
od188238/2019_2020 : ODP -2 Supply ,Installation, testing & Commisioning of Outdoor Lighting Panel (ODP) cubicle type, made out of Thermoplastic UV resistant enclosure, totally enclosed, IP65, free standing, pedestal mounted dust and vermin proof, powder coated, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides,including all the necessary internal wiring ,suitable spreader etc. .Panel shall be with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. Incomer:63 A, FP, 25kA, MCCB with adjustable thermal magnetic release with OL & SC protection - 1 No BUSBAR 63A TPN busbars of high conductivity electrolytic quality copper alloy INSTRUMENTS 4A, C curve SP MCB - 3 Nos. RYB indication lamp, LED type - 1 Set (0-500V) voltmeter with selector switch- 1set br>(0-63)A ammeter Acc. class 1 with 90 deg defl. scale - 3Nos 24 hrs Digital time switch with inbuilt battery - 1 No 63A, AC-1 contactor - 1 No Surge protection device-type 1+2-Nos OUTGOINGS 25A C Curve FP 100mA RCCB+MCB-6 Nos

1

-

-

... More
od38417/2021_2022 : 5 kVA UPS Supply, Installation, Testing and Commissioning of 5 kVA,single phase input,single Phase output, true on-line UPS System with 15 minutes back up , output isolation transformer, voltage stabilizerincluding all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories cabling etc as required complete having following specification. RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Regulated output voltage & frequency. Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation, Remote Management Interphase, Back up time 15 minutes at full load

1

-

-

... More
HT CABLING

-

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

70

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

5

-

-

... More
10.4.3 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:240 sq. mm

3

-

-

... More
10.5.3 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 sq. mm

1

-

-

... More
od38507/2021_2022 : Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required Above 120 sq. mm and upto 400 sq. mm

10

-

-

... More
od75642/2021_2022 : 3 core 240 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments

84

-

-

... More
LT CABLING

-

-

-

... More
od186144/2019_2020 : Supplying and making end termination with brass compression gland and copper lugs for following 3C 4 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

24

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

6

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

14

-

-

... More
od186157/2019_2020 : Supplying and making end termination with brass compression gland and copper lugs for following 4C 1.5 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

12

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

1113

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

5

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

75

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

860

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

80

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

15

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

642

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

65

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

252

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

13

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

15

-

-

... More
14.13.4 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required150 mm dia

20

-

-

... More
14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia

25

-

-

... More
od186163/2019_2020 : Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke & Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

2

-

-

... More
od186164/2019_2020 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

500

-

-

... More
od309944/2019_2020 : Supplying and making end termination with brass compression gland and copper lugs for 4C 4 sqmm Cu cable

126

-

-

... More
od309946/2019_2020 : Supplying and making end termination with brass compression gland and copper lugs for following 2C 4 sqmm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

14

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

5

-

-

... More
7.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

10

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

140

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

10

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

10

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

10

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

20

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

4

-

-

... More
9.1.13 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm)

4

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

8

-

-

... More
od39723/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
od39724/2021_2022 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved arequired.

1

-

-

... More
od75637/2021_2022 : 4 sqmm 4 core PVC/XLPE insulated armoured cable with copper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE

1704

-

-

... More
od75638/2021_2022 : 16 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

318

-

-

... More
od75639/2021_2022 : 4 sqmm 2 core PVC/XLPE insulated armoured cable withcopper conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE

102

-

-

... More
od75640/2021_2022 : Supply of 4C 1.5 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

54

-

-

... More
od75641/2021_2022 : 10 sqmm 3 core PVC/ XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

36

-

-

... More
od75643/2021_2022 : 4 sqmm 3 core PVC/XLPE insulated armoured cable with copper conductors for working Voltages up to and including 1100 volts conforming IS 1584/part I/ 1988 for PVC IS 7098 part I for XLPE

150

-

-

... More
od75645/2021_2022 : 35 sqmm 4 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

588

-

-

... More
od75646/2021_2022 : 70 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

42

-

-

... More
od75647/2021_2022 : 185 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

264

-

-

... More
od75982/2021_2022 : 95 sqmm 3 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE

36

-

-

... More
od101669/2021_2022 : Fabrication, supply and installation of following 600 mm WIDTH X 75 mm DEPTHX 2 mm THICK size of ladder type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and painting etc as required

30

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

6

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

6

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

5

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

3

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

2

-

-

... More
od186137/2019_2020 : Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.

3

-

-

... More
od186141/2019_2020 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

3

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

34

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

2

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

3835

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

3565

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

100

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

62

-

-

... More
od75631/2021_2022 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

144

-

-

... More
od75632/2021_2022 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

8

-

-

... More
od75633/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

185

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

2111

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

1720

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

1960

-

-

... More
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm

60

-

-

... More
od126174/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

21

-

-

... More
DB AND ACCESSORIES

-

-

-

... More
od186080/2019_2020 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

5

-

-

... More
od186130/2019_2020 : Supply, Installation, Testing & Commissioning of 32A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. Make: Enclosure- Siemens 8GB32100RC0X or equivalent approved make

2

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

2

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

138

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

23

-

-

... More
od186667/2019_2020 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole

6

-

-

... More
od186668/2019_2020 : Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, D curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

12

-

-

... More
od186669/2019_2020 : Supplying and fixing 40 A to 63 A rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole

11

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
od186155/2019_2020 : Providing and fixing following 100 Amp,25kA,FP MCCB rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

2

-

-

... More
od239924/2019_2020 : Supply, Installation, Testing & Commissioning of 63 A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

2

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

2

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

2

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

4

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
od39506/2021_2022 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers in existing MCB DB as required. 6-32A FP MCB

4

-

-

... More
od40786/2021_2022 : Supply, installation , testing and commissioning of DOL starter upto 5Hp , 3p motors including auxillory contactors, push buttons and all necessay accessories as required complete . The starter enclosure shall be made of powder coated 1.6 mm CRCA sheet

13

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

3

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

3

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od126180/2021_2022 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

2

-

-

... More
od126181/2021_2022 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

3

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od188223/2019_2020 : Supply , installation, testing and commisioning of up down light LED IP65 rated along with driver,system wattage maximum of 6*2 Watts,lumen output of lamp , power factor >0.9,THD<10%rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watts,with suitable driver and including all necessary accessories as required complete.Make:- Cat No: Klite WALL TRIO or equivalent approved make)

10

-

-

... More
1.42 : Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

240

-

-

... More
od186864/2019_2020 : Installation, testing and commissioning of Wall fan, including wiring the down rods of standard length with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

3

-

-

... More
od186865/2019_2020 : Supply of LED Flood light luminaire of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 400W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens not less than 46000 and system efficiency greater than or equal to 115 lumen/watt. The Light fitting shall be with all required accessories suitable for mounting on an octagonal pole including 10k inbuilt SPD. The luminaire should meet all the technical specifications as mentioned. (Make: Crompton CFS-506-400-57-30D-SL-GL-NBR or Wipro LF20-502-060-57-G4 or equivalent approved make)

50

-

-

... More
od186866/2019_2020 : Supply installation, testing and commissioning of octagonal pole of 12 meter for mounting 4 nos of 400 W LED flood light or as per actual lux requirements. The pole shall be hot dipped galvanized and fixing assembly on the pole top. The pole with flood light mounting assembly and built-in cylindrical GI control box shall be of same material .The control gear box is prewired with FP MCB, FP connector for easy loop-in loop-out suitable for 3phase 4 wire AC supply. From this control gear box to the luminaires 5 core 2.5 sq mm copper flexible XLPE cable through flexible conduit shall be used. The pole shall have provision for connecting the earth wire and cable gland arrangement.. The mast has been designed considering base wind speed i.e. 39 m/s. Mast will be equipped with monkey ladder to access the top for maintenance. The Top dia shall be 90mm and bottom shall be 240mm with 3mm sheet thickness .Minimum galvanizing thickness of 70 microns should be maintained uniform throughout the pole.

4

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

340

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

23

-

-

... More
od309447/2019_2020 : Supply installation, testing and commissioning of surface mounting, octagonal pole of 9 meter height bracket suitable for mounting 2 nos of LED Light fixtures. The pole shall be hot dipped galvanized and fixing assembly on the pole top. The pole with flood light mounting assembly and built-in cylindrical GI control box shall be of same material .The control gear box is prewired with FP MCB, FP connector for easy loop-in loop-out suitable for 3phase 4 wire AC supply. From this control gear box to the luminaires 3 core 2.5 sq mm copper flexible XLPE cable through flexible conduit shall be used. The pole shall have provision for connecting the earth wire and cable gland arrangement. Minimum galvanizing thickness of 70 microns should be maintained uniform throughout the pole. ( Crompton or equivalent approved make)

4

-

-

... More
od309668/2019_2020 : Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required.

20

-

-

... More
od39746/2021_2022 : Supply of LED recess mounted downl light fixture light made of pressure diecast housing, along with driver,maximum system wattage of 12 Watts with lumen output of lamp not less than 1200 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No:WIPRO LD90-141-XXX-65-XX or equivalent one)

2

-

-

... More
od39747/2021_2022 : Supply of LED recess mounted down light made of die cast aluminium, along with driver,system wattage of 18 Watts, CCT- 5700K (warm white) with lumen output of luminaire greater than 18500lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO LD90-231-XXX-65-XXor equivalent approved make

18

-

-

... More
od39760/2021_2022 : Supply of LED surface mounted down light fixture light made of pressure diecast housing, along with driver, maximum system wattage of 18 Watts with lumen output of lamp not less than 1530 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 85 lumen/watt and including all necessary accessories as required complete. Make:- Cat No:WIPRO LD80-171-XXX-60-SM or equivalent one)

64

-

-

... More
od39762/2021_2022 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser, along with driver,with a maximum system wattage of 20 Watts,lumen output of luminaire greater than 2000, power factor >0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Osram Luxsmart LED batten G2 or equivalent approved make

96

-

-

... More
od39763/2021_2022 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate Diffuser ,along with driver,with a maximum system wattage of 10 Watts,lumen output of luminaire greater than 1000, power factor > 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: OSRAM LUXSMART led BATTEN G2 or equivalent approved make

34

-

-

... More
od39764/2021_2022 : Installation, testing and commissioning of High bay/Mid bay//industrial/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable as required.

34

-

-

... More
od39765/2021_2022 : Supply of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.(Make crompton-SDX white or equivalent approved make).

3

-

-

... More
od39766/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make)

22

-

-

... More
od39767/2021_2022 : Supply of 10w LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP66 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required. (Make:Wipro LW07 or equivalent approved make)

35

-

-

... More
od39768/2021_2022 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)

15

-

-

... More
od39791/2021_2022 : Supply, installation, testing and commissioning of 7m single arm long Hot dipped GI pole with built- in control box prewired, with pole suitable for mounting one number of LED luminarie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, and all other accessories as required complete. Along with LED Lamp with die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 45 watts, lumen output not less than than 4500 lumen, System efficacy not less than 100 lumen per watt ,power factor >= 0.9, IP 66 compliant including all necessary accessories as required complete. Note: Incoming and outgoing cable at termination box shall be terminated with glands properly.( Luminairie Make: Wipro LR02-501-XXX-57-G1 -or equivalent approved make)(Pole Make-UEPL 005)

30

-

-

... More
od39795/2021_2022 : Supply of LED Flood light luminaire of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 250W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens not less than 27500 and system efficiency greater than or equal to 110 lumen/watt. The Light fitting shall be with all required accessories including inbuilt 10kV SPD and suitable for mounting on an octagonal pole. The luminaire should meet all the technical specifications as mentioned. (Make: Crompton CFS-506-250-57-60D-SL-GL-NSG or Wipro LF30-342-060-57-XX or equivalent approved make)

8

-

-

... More
od40990/2021_2022 : Installation Testing & Commissioning of LED flood light fixture made of die cast aluminium, along with driver, in 9/12 m octagonal pole including all necessary accessories as required for the light fixture.

24

-

-

... More
od41709/2021_2022 : Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector, with maximum system wattage of 40 Watts,lumen output of luminaire greater than 4000 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24

6

-

-

... More
EARTHING AND ACCESORIES

-

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

475

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

200

-

-

... More
od39683/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 4mm GI (8 SWG)

900

-

-

... More
od39684/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 3.15mm Cu (10 SWG)

300

-

-

... More
od39685/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 25mm X 3 mm Cu

50

-

-

... More
od39686/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 50mm X6mm GI

250

-

-

... More
od39687/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 4mm GI (8 SWG)

85

-

-

... More
od39688/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 3.15mm Cu (10 SWG)

1000

-

-

... More
od39689/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 25mm X 3 mm Cu

50

-

-

... More
od39690/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 50mm X6mm GI

100

-

-

... More
od39691/2021_2022 : Providing and fixing 4 swg Cu strip/wire on surface or in recess for connections etc. as required.

40

-

-

... More
od39692/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 4 swg Cu

20

-

-

... More
od39693/2021_2022 : Supply of Earthing with C.I. earth pipe 3 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)

33

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
od186083/2019_2020 : Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32 mm x 6mm and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.

10

-

-

... More
od186088/2019_2020 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

200

-

-

... More
od186095/2019_2020 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

300

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

220

-

-

... More
SAFETY EQUIPMENTS

-

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
od186089/2019_2020 : Supply of Rubber hand gloves suitable for 11 kV.

1

-

-

... More
od186096/2019_2020 : Supply of First aid box

1

-

-

... More
od186102/2019_2020 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS:DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

8

-

-

... More
od186109/2019_2020 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

1

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od37310/2021_2022 : Supply, Installation, Testing and Commissioning of electric driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 70m head conforming to IS 1520. (b) Suitable HP squirrel cage induction motor, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads/ mounts.

1

-

-

... More
od37316/2021_2022 : Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal, split casing, centrifugal type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 70m head conforming to IS 1520. (b) Suitable HP and RPM water cooled diesel engine with radiator, conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,2x12V 180AH Batteries and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity for 8 hour operation) with level indicator, By-pass line, piping to diesel tank from engine, exhaust pipe extended outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads/mounts. (e) Diesel engine control panel.

1

-

-

... More
od37318/2021_2022 : Supply, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification (a) Horizontal, centrifugal type pump of cast iron body, bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 70 m head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, suitable synchronous speed, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) Suitable cement concrete foundation, foundation bolts etc. as required.

1

-

-

... More
od37324/2021_2022 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8 BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

4

-

-

... More
od37325/2021_2022 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4 BSP(F) connection IP:30 enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC with ball valve etc. complete as required as per technical specification.

3

-

-

... More
od37328/2021_2022 : Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
od37330/2021_2022 : Supply, Installation, Testing and Commissioning of 200 mm nominal dia (6 mm thickness) MS(Heavy C' Class) pipe IS: 3589 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

24

-

-

... More
od37332/2021_2022 : Supply, Installation, Testing and Commissioning of 150 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

55

-

-

... More
od37333/2021_2022 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

57

-

-

... More
od37334/2021_2022 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

16

-

-

... More
od37337/2021_2022 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

98

-

-

... More
od37338/2021_2022 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

40

-

-

... More
od37339/2021_2022 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

102

-

-

... More
od37341/2021_2022 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

55

-

-

... More
od37342/2021_2022 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

137

-

-

... More
od37343/2021_2022 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 150 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

294

-

-

... More
od37344/2021_2022 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 100 mm dia conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, GI nuts bolts, gaskets etc. in ground at a depth of 1m including excavation & providing cement concrete blocks as supports, applying bituminous primer, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification.

57

-

-

... More
od37345/2021_2022 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

7

-

-

... More
od37346/2021_2022 : Supply, installation, testing and commissioning of dual plate non-return valve of 150 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

2

-

-

... More
od37347/2021_2022 : Supply, installation, testing and commissioning of dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

1

-

-

... More
od37348/2021_2022 : Supply, installation, testing and commissioning of dual plate non-return valve of 65 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

1

-

-

... More
od37349/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 200 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

2

-

-

... More
od37350/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 150 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

9

-

-

... More
od37351/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

5

-

-

... More
od37352/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 80 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

1

-

-

... More
od37353/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 65 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

5

-

-

... More
od37354/2021_2022 : Supply, installation, testing and commissioning of butterfly valve of 40 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

4

-

-

... More
od37355/2021_2022 : Providing, installation, testing and commissioning of 150 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

2

-

-

... More
od37356/2021_2022 : Providing, installation, testing and commissioning of 100 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od37357/2021_2022 : Providing, installation, testing and commissioning of 80 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od37358/2021_2022 : Supply,installation, testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain, GI nuts, bolts, gasket etc as per technical specification.

14

-

-

... More
od37359/2021_2022 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. Pipe

8

-

-

... More
od37360/2021_2022 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

28

-

-

... More
od37361/2021_2022 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

14

-

-

... More
od37362/2021_2022 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

14

-

-

... More
od37363/2021_2022 : Supply, installation, testing and commissioning of Fire brigade collective breaching with 4 Nos. gunmetal 63 mm dia instantaneous type male couplings and built in check valves and 150mm dia inlet connection complete with GI nuts, bolts, gasket etc as required as per technical specification.

2

-

-

... More
od37365/2021_2022 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as per the technical specification

4

-

-

... More
od37366/2021_2022 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage pendant type sprinkler;1/2 NPT, K -5.0, Chrome Finish with rosette plate; operating temperature at 68 degC complete as required as per the technical specification.

12

-

-

... More
od37367/2021_2022 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage upright type sprinkler ;1/2 NPT, K -5.0, Chrome Finish; operating temperature at 68 degC complete as required as per the technical specification.

16

-

-

... More
od37368/2021_2022 : Providing, fixing, testing & commissioning of UL listed sprinkler of the following type: Standard response, Extended coverage sprinkler, horizontal sidewall sprinkler ;1/2 NPT, K -11.2, Chrome Finish; operating temperature at 68 deg. C. complete as required as per the technical specification.

28

-

-

... More
od37369/2021_2022 : Supply, installation, testing and commissioning of 1m unbraided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc as required as per technical specification.

12

-

-

... More
od37370/2021_2022 : Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1 to 6 . The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 complete with all accessories as required as per the technical specification.

4

-

-

... More
od37371/2021_2022 : Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification.

1

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od37309/2021_2022 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

13

-

-

... More
od37314/2021_2022 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

1

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
od37312/2021_2022 : Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke & heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

19

-

-

... More
od37315/2021_2022 : Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.The product must be UL listed and FM approved, complete in all respect as per technical specification.

2

-

-

... More
od37317/2021_2022 : Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

9

-

-

... More
od37320/2021_2022 : Supply, installation, testing and commissioning of conventional type wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

9

-

-

... More
od37323/2021_2022 : Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

2

-

-

... More
od37326/2021_2022 : Supply, installation, testing and commissioning of 2A 24V Power supply unit for hooters/ beam detectors complete in all respect and as required as per technical specification.

1

-

-

... More
od37327/2021_2022 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

7

-

-

... More
od37329/2021_2022 : Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

12

-

-

... More
od37331/2021_2022 : Supply, installation, testing and commissioning of public address and talk back system consisting of 8 zone public address cum talkback console with mike and selector, multiple channel talk back facility with battery charger, suitable capacity battery, suitable mic, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier (min 100W), amplifier rack if required etc. complete as required for meeting the technical specifications.

1

-

-

... More
od37335/2021_2022 : Supply, installation, testing and commissioning of EN/UL/FM/LPCB approved/ listed, microprocessor based 1 loop intelligent addressable main fire alarm panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to integrate with analog/digital voice evacuation system (PA-talkback system) and shall be complete with all necessary accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers

1

-

-

... More
od37336/2021_2022 : Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring purpose and send the signal from a flow switch to the alarm panel for initiating alarm when flow occur, as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

4

-

-

... More
od37340/2021_2022 : Supply and laying of 2x 1.5sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground, on wall surface or recess as required as per the technical specifications.

1397

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

60

-

-

... More
SIGNAGES

-

-

-

... More
od37311/2021_2022 : Supply and installation of photoluminescent glow signage such as Fire Duct/Fire Lift/Staircase/Fire Station/Hosereel signboard etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite, panel conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

16

-

-

... More
od37313/2021_2022 : Supply and installation of photoluminescent glow signage of FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

1

-

-

... More
od37319/2021_2022 : Supply and installation of photoluminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification

4

-

-

... More
od37322/2021_2022 : Supply and installation of photoluminescent glow signage such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

12

-

-

... More
od37547/2021_2022 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407. Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.