KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Sep 2024
Closing Date19 Oct 2024
Tender Amount₹ 3,27,00,000 
Notes
Download

Costs

Summary

Construction Of Critical Care Block At Gh Pathanamthitta Electrical And Mechanical Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

140.8

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

38.28

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

25595.2

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

12375

-

-

... More
90.14.10.2 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

22

-

-

... More
90.14.10.4 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

2

-

-

... More
od386907/2022_2023 : Supplying and fixing of 2 A SP MCB (C curve), 10 kA breaking capacity in the existing panel for control devices as required in complete.

30

-

-

... More
od386911/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - BLUE Colour in the existing panel.

6

-

-

... More
od386912/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, up to 160A

27

-

-

... More
od386914/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, 320A-400A

1

-

-

... More
od386915/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour in the existing panel.

12

-

-

... More
od386923/2022_2023 : Supplying and fixing of Resin Cast metering CT 63/5A 10VA accuracy class 1, in existing panel and giving connection complete.

3

-

-

... More
od386925/2022_2023 : Supplying and fixing of Resin Cast metering CT 125/5A 5VA accuracy class 1, in existing panel and giving connection complete.

11

-

-

... More
od386934/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 4 POLE MCCB ISOLATOR

1

-

-

... More
od387486/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 40A, 3 POLE MCCB ISOLATOR

2

-

-

... More
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

27

-

-

... More
90.14.11.15 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A

1

-

-

... More
od387846/2022_2023 : Supply , conveyance and Fixing three phase voltmeter accuracy class1 in the existing Panel as required.

2

-

-

... More
od387849/2022_2023 : Supply , conveyance and Fixing three phase ammeter accuracy class1 in the existing Panel as required.

4

-

-

... More
od387941/2022_2023 : Supply installation, testing and commissioning of three phase DOL starter suitable for 0.25 to 7.5 HP , 440v, 50 Hz in existing panel as required .

7

-

-

... More
od387943/2022_2023 : Supply , conveyance and Fixing voltmeter selector switch in the existing Panel as required.

2

-

-

... More
od387944/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 100A, 3 POLE MCCB ISOLATOR

2

-

-

... More
od387945/2022_2023 : Supply , conveyance and Fixing Ammeter selector switch in the existing Panel as required.

1

-

-

... More
od388051/2022_2023 : Supply and installation of ON OFFindication lamp in existing panel as required

22

-

-

... More
od398220/2022_2023 : Supply and Fixing of Digital Multifunction meter to read: W, Wh, PF or VA, Vah, PF or V AR, V ,A Rh, PF - 3 phase accuracy class 1 LED in the existing Panel as required.

9

-

-

... More
od14307/2023_2024 : Supplying and fixing of Resin Cast metering CT 400/5A 10VA accuracy class 1, existing panel and giving connection complete

1

-

-

... More
od14308/2023_2024 : Supply and installation of push button in existing panel as required

10

-

-

... More
od14309/2023_2024 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 25/36 kA (Ics=100%Icu), 3 pole and neutral link current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

2

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

1

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

9

-

-

... More
od15665/2023_2024 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 3 POLE MCCB ISOLATOR

1

-

-

... More
od42420/2023_2024 : Supply installation, testing and commissioning of FASD starter for 40 hp , 440v, 50 Hz in existing panel as required

1

-

-

... More
od42421/2023_2024 : Supply installation, testing and commissioning of FASD starter suitable for 5 hp ,440v, 50 Hz in existing panel as required

1

-

-

... More
od42526/2023_2024 : Supplying and fixing of Resin Cast metering CT 100/5A 15VA accuracy class 1, in existing panel and giving connection complete.

3

-

-

... More
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required125 Amp, 36 KA

2

-

-

... More
od42609/2023_2024 : Supply, Installation, Testing & Commissioning of 100A FP MCCB isolator in IP65 weather proof enclosure on surface including all the mounting accessories, internal wiring etc as required complete

2

-

-

... More
od42624/2023_2024 : Supply, conveyance and fixing the following types & current rated control gears switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 400A, 25/36 kA (Ics=100%Icu), 4 pole and neutral link current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

1

-

-

... More
od68922/2023_2024 : Supply, Installation, Testing & Commissioning of 25/32A FP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

2

-

-

... More
od76563/2023_2024 : Supplying and fixing of SPD Class B+C/Type 1+2, Multi stage protection device should be suitable for TNS configuration and should be DIN Rail mounting type. Surge Protection Device Tested as per IEC 61643 Part 11:2016 . Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV . The Surge Protection Devices should have TOV safe fail for 120 Min : 442 V and without Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25 kA/50 kA . Complete with back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <25 nano sec. The product should be tested and approved by any one of the following external testing institutes (UL, KEMA, OVE, VDE)

1

-

-

... More
CABLES AND CABLING

-

-

-

... More
od306814/2022_2023 : Supply of 4C 16 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

590

-

-

... More
od306815/2022_2023 : Supply of 4C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

365

-

-

... More
od306817/2022_2023 : Supply of 3.5C 120 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

88

-

-

... More
od306831/2022_2023 : Supply of 3C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

88

-

-

... More
od306832/2022_2023 : Supply of 2C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

325

-

-

... More
od306833/2022_2023 : Supply of 4C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

567

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

675

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

45

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1276

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

80

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

130

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

25

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

18

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

270

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness

210

-

-

... More
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
4.7.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

8

-

-

... More
4.8.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.8.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.8.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.9.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.9.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Cross member ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.9.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.10.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.10.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
od309083/2022_2023 : Supply of 3C 6 sqmm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date

22

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

10

-

-

... More
od309390/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 6 sq.mm

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

30

-

-

... More
9.1.10 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 35 sq. mm (28mm)

2

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

50

-

-

... More
od392063/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 70 sqmm Al

165

-

-

... More
od399651/2022_2023 : Supply of 3C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

22

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

220

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

220

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

100

-

-

... More
od402752/2022_2023 : Supply of 3.5C 185 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Al conductor cable conforming to IS 7098 (Part 1) amended upto date.

550

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

11

-

-

... More
od42718/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.3C 4 Sq.mm Cu

16

-

-

... More
od49552/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.2C 4 Sq.mm Cu Code

16

-

-

... More
od49852/2023_2024 : Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C 4 Cu

34

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

10

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

20

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

356

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

20

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

2532

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1708

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

2000

-

-

... More
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

180

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

300

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

750

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

450

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

110

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

55

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

110

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

55

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

3

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

74

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

10

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

55

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

75

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

3

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

184

-

-

... More
od305266/2022_2023 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

23

-

-

... More
od305268/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

33

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

55

-

-

... More
MCBs AND DISTRIBUTION BOARDS

-

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

17

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

6

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

7

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

216

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

22

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

40

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
od309048/2022_2023 : Supply, Installation, Testing & Commissioning of 25/32A DP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

2

-

-

... More
od309049/2022_2023 : Supply, Installation, Testing & Commissioning of 25/32A FP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

6

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
od365386/2022_2023 : Supply and fixing of following 40-63A FP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required

9

-

-

... More
od367250/2022_2023 : Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "D" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

176

-

-

... More
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

17

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

2

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

6

-

-

... More
od395788/2022_2023 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6-32A TP MCB, D-CURVE

4

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

7

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

11

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

11

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
od50490/2023_2024 : Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete

1

-

-

... More
od50506/2023_2024 : Supply, Installation, Testing & Commissioning of 400A, TP+NL, 36 KA, MCCB with rotary handle in the existing substation main panel in the outgoing side replacing existing 250A breaker including all necessary fabrications, bus bar, instruments, control devices and required control wiring etc. which is similar to other outgoings in complete installation capable for charging the feeder.

1

-

-

... More
od50563/2023_2024 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.4 pole

11

-

-

... More
od52320/2023_2024 : "Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing panel complete with connections, testing and commissioning etc. as required. Triple pole and Neutral"

11

-

-

... More
od58984/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6-32A DP MCB, D-CURVE

7

-

-

... More
od59302/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40-63A FP MCB, D-CURVE

6

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od305288/2022_2023 : Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal framework working on 230 V AC supply complete with all accessories as required.

28

-

-

... More
od305290/2022_2023 : Supply of 450mm sweep heavy duty exhaust fan in metal body with grill/ louvers working on 230 V AC supply complete with all accessories as required

4

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

420

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

567

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

32

-

-

... More
1.42 : Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

30

-

-

... More
od309335/2022_2023 : Supplying and fixing extra conduit down rod of G.I. pipe 15 mm dia, heavy gauge including painting etc. for ceiling fans as required

79

-

-

... More
od309336/2022_2023 : Supplying and fixing Metal conduit Pipe of more than 8 mm dia, including powder coating/Spray painting similar to the colour shade of the light fixture and all accessories in complete for suspending the light fixture as required.

620

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

80

-

-

... More
od386692/2022_2023 : Supply of 10 (+/-2) W High efficient LED batten surface/wall mounted, System efficacy of more than 100 lm/W and lumen output of luminaire greater than 1000 lumen, designed extruded channel in thermally conductive material with plastic with HET diffuser. CRI >80, Power factor>0.9, CCT - 6500K, 50000 burning hours as per L 70 criteria.

47

-

-

... More
od386693/2022_2023 : Supply of 40W (+/-2) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing & High Efficiency Translucence (HET) diffuser. CRI>80, IP65 from front, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Powerfactor>0.9, Surge protection-2 kV, prewired electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation

8

-

-

... More
od16036/2023_2024 : Supply of 18W (+/-2), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life THD0.9, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

7

-

-

... More
od16037/2023_2024 : Supply of 18W, High efficient surface mounted LED round downlighter with white powder coated,Aluminium die cast aluminium housing.CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD0.9, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

20

-

-

... More
od16038/2023_2024 : Supply of 36W , High efficient recess mounted 2 x 2 LED luminaire with CRCA housing &CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @L70 life.THD0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy> 110 lm/W including all accessories necessary as required to complete installation.

51

-

-

... More
od16039/2023_2024 : Supply of Integral 2x2 LED, IP 20, 36W LED Surface mounted fixture with System efficacy of more than 100lm/W and system lumen output 3000lm. Luminaire shall have translucence HET diffuser for Uniform illumination and wider light distribution. LED. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. .

13

-

-

... More
od53037/2023_2024 : Supply of 40W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire

71

-

-

... More
od54000/2023_2024 : Supply of Integral, SMD 1x4 LED, IP 20, 36W +/- 4W LED Suspended light fixture with System efficacy not less than 110 lm/W and system lumen output more than 3600lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA housing. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Required nos. of Clamps and other accessories suitable for mounting Conduit pipe/rod to suspend the fixture from the ceiling.

110

-

-

... More
od58351/2023_2024 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

80

-

-

... More
od58352/2023_2024 : Supply of 20W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire

107

-

-

... More
od75708/2023_2024 : Supply of IP 65 & IK 08 LED surface mounted Bulkhead fixture with System efficacy of more than 105 lm/W. Luminaire shall be made up of Die Cast Aluminium for efficient heat dissipation. Luminaire shall have Polycarbonate diffuser for Uniform illumination and wider light distribution. The LEDs used should be with CCT of 5700 K and CRI > 70, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% including all accessories necessary as required to complete installation.

11

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

10

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

130

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

180

-

-

... More
od305460/2022_2023 : Supply and fixing of First aid box

1

-

-

... More
od305461/2022_2023 : Supply and fixing anodised aluminum glass framed shock treatment chart.

2

-

-

... More
od305462/2022_2023 : Supplying of Rubber hand gloves suitable for 11 KV.

1

-

-

... More
od309152/2022_2023 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size including lamination etc. as required complete on wall.

1

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

3140

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

270

-

-

... More
od399693/2022_2023 : Earthing with CI earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
od55236/2023_2024 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of size 2m x 1m for 3.3kV grade 2mm thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound

15

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

100

-

-

... More
od160083/2023_2024 : Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

100

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

230

-

-

... More
od308770/2022_2023 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip

10

-

-

... More
od308777/2022_2023 : Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing masonry enclosure with heavy duty CI cover plate of 300X300 mm having locking arrangement.

10

-

-

... More
od50571/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for Sheet roof with the required mounting clamps , cross connectors , expansionpiece and other accessories required as per IEC 62305-3

165

-

-

... More
od50572/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

420

-

-

... More
UPS AND ACCESSORIES

-

-

-

... More
od11063/2023_2024 : Supply, Installation, Testing and Commissioning of 40kVA (N+1 arrangement), three phase input, three phase output, true on-line modular UPS system with 15 minutes back up at unity pf, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc. as required complete having following specification. The UPS system consist of 2 no's of 20 KVA modular units and must have an N+1 rack for mounting UPS modules. Aso required a set of battery bank mounted in battery racks.. Fully digital controlled based on DSP. Power factor corrected from end 0.95 Pure sine wave output. Full time output voltage & frequency regulation. Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch, Auto temperature compensation etc. as required

1

-

-

... More
HVAC SYSTEMS

-

-

-

... More
od307640/2022_2023 : Supply, Installation ,testing and commissioning of the following minimum capacity Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between IDUs, ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units). 38 HP

1

-

-

... More
od307648/2022_2023 : Supply, Installation , testing and commissioning of the following capacity VRF compatible Air handling units with AHU Kit with VFD starter with all standard fittings, outlet volume control dampers, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/Sq.ft. of coil surface area for equal distribution, filter section shall comprise of prefilter The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) and bag filter of 99.97% efficiency down to 0.3 micron (MERV 17- HEPA) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement flexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller for UV lamps, thermostat, control wiring with necessary control cabling , complete with necessary vibration isolators, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, PVC drain pipe connections(upto 5 m) with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc ,power/control cabling from power supply, etc. complete in all respects as per technical specifications.25TR (10000 CFM) - 50 mm of WG ESP

1

-

-

... More
od307659/2022_2023 : Supply, Installation, testing, and commissioning of the following minimum capacity Double skin, sheet metal VRF compactable Ceiling Suspended Unit including AHU kit, all accessories as required as per technical specifications complete with outlet volume control dampers, canvas connections, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be a minimum 12watt/sq.ft. of coil surface area for equal distribution, The efficiency of the filters shall be 90% down to a particle size of 10 microns (MERV-8) and bag filter of 99.97% efficiency down to 0.3 microns (MERV 17-HEPA) filters complying to ASHRAE 52.2, cooling coil of copper tube and aluminum fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, power wiring and power/control cabling(indoor to outdoor), digital thermostat with required control wiring, required starter and starter panel, structural supports for fixing IDU, safety devices etc. the following minimum capacity and the cooling coil (min 4 rows), suitable for three-phase 440V supply, complete in all respects as per technical specifications.(Minimum External Static Pressure 25 mmwc )4 TR-1600 CFM - 25 mm of WG ESP

1

-

-

... More
od307665/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/4") 44.45 mm

10

-

-

... More
od307667/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 5/8") 41.275 mm

12

-

-

... More
od307669/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/2") 38.1 mm

10

-

-

... More
od307671/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8") 34.925

12

-

-

... More
od307672/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/4") 31.75 mm

10

-

-

... More
od307673/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8") 28.575 mm

10

-

-

... More
od307674/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 7/8") 22.22 mm

10

-

-

... More
od307675/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4") 19.05 mm

12

-

-

... More
od307676/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8") 15.875 mm

24

-

-

... More
od307677/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2") 12.7 mm

10

-

-

... More
od307678/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/8") 9.525 mm

36

-

-

... More
od307679/2022_2023 : Supply, Installation ,testing and commissioning of PDI Compatible central controller, along with associated accessories for controlling entire VRF system & 25% spare capacity for future provisions with suitable interconnecting control cabling between IDUs, ODUs and central controller ,Power wiring with necessary supports and complete in all respects as per the technical specifications.

1

-

-

... More
od307680/2022_2023 : Supply, installation, testing and commissioning of suitable dia PVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth along with required pipe fittings and accessories like Bends, Tees, reducers, clamps, suitably supported etc. complete in all respects as per the technical specifications.

50

-

-

... More
od307681/2022_2023 : Supply, Installation,Testing and Commissioning of minimum 2 TR Split air conditioning unit minimum capacity Invertor Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 3 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports, necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe (upto 5 m) 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulationfinished with 7 mils factory laminated treated fibre glass cloth, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, , first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete as required as per technical specification

2

-

-

... More
od307683/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.100 CFM -10 mm WG

3

-

-

... More
od307684/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.<be>400CFM-10mm ESP

2

-

-

... More
od307685/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 500CFM-10mm ESP

1

-

-

... More
od307686/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 600CFM-10mm ESP

1

-

-

... More
od307687/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 700CFM-10mm ESP

1

-

-

... More
od359492/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 1000 CFM -10 mm WG

1

-

-

... More
od308327/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 2250CFM -15mm of WG

1

-

-

... More
od308328/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 2500CFM -15mm of WG

1

-

-

... More
od308329/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 13000CFM -15mm of WG

2

-

-

... More
AIR DISTRIBUTION

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

335

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

390

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

15

-

-

... More
16.12.1.4 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

10

-

-

... More
od307647/2022_2023 : Supply, Installation, testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1 with antimicrobial properties. ,having density of 140-180 kg/m3 ,fixing of insulation using OEM recommended fixing details ,supports and adhesive, tapes etc. complete in all respects as per the technical specifications

51

-

-

... More
16.23.2 : INSULATION ON EXISTING PIPE br 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm

538

-

-

... More
od307652/2022_2023 : Supply & fixing of Acoustic Insulation of AHU Rooms using open cell processed nitrile rubber having a density of 140-180 Kg/m3 and thickness of 25 mm with anti-microbial protection with suitable frame works etc. complete in all respects as required by the technical specifications

106

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

6

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

6

-

-

... More
od307660/2022_2023 : Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers ,bird screen etc. complete in all respects as per the technical specifications.

4

-

-

... More
od307664/2022_2023 : Supply, Installation , testing and commissioning of Aluminium Extruded Fresh air louvers with fresh air damper, bird screen etc complete in all respects as per the technical specifications.

2

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

4

-

-

... More
od307668/2022_2023 : Supply, Installation ,testing & commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks , complete in all respects as per the technical specifications.

3

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od108379/2023_2024 : Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 1620 lpm at 70 m Head

1

-

-

... More
od108384/2023_2024 : Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 70 m Head.

1

-

-

... More
od108388/2023_2024 : Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) a. Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head

1

-

-

... More
od108392/2023_2024 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

4

-

-

... More
od108395/2023_2024 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC, with ball valve etc. complete as required as per technical specification.

3

-

-

... More
od108397/2023_2024 : Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
od108401/2023_2024 : Supply, Installation, Testing and Commissioning of 150 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

136

-

-

... More
od108403/2023_2024 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

168

-

-

... More
od108406/2023_2024 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

38

-

-

... More
od108407/2023_2024 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

72

-

-

... More
od108408/2023_2024 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

72

-

-

... More
od108409/2023_2024 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

291

-

-

... More
od108410/2023_2024 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

121

-

-

... More
od108411/2023_2024 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

714

-

-

... More
od108412/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 150 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

195

-

-

... More
od108413/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

14

-

-

... More
od108414/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 150 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

2

-

-

... More
od108415/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

1

-

-

... More
od108416/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 65 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

1

-

-

... More
od108417/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 150 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

11

-

-

... More
od108418/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

10

-

-

... More
od108419/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 80 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

1

-

-

... More
od108420/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 65 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

1

-

-

... More
od108421/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 40 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all Accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

8

-

-

... More
od108422/2023_2024 : Providing, installation, testing and commissioning of 150 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

2

-

-

... More
od108423/2023_2024 : Providing, installation, testing and commissioning of 80 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od108424/2023_2024 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification.

12

-

-

... More
od108425/2023_2024 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. Pipe

8

-

-

... More
od108426/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

24

-

-

... More
od108427/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

12

-

-

... More
od108428/2023_2024 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

12

-

-

... More
od108429/2023_2024 : Supply, installation, testing and commissioning of 4-WAY FIRE BRIGADE inlet connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

2

-

-

... More
od109457/2023_2024 : Supply, installation, testing and commissioning of draw off connection with CI body and gunmetal coupling, complete with GI nuts, bolts, gasket etc as required as per technical specification.

1

-

-

... More
od108430/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage pendant type sprinkler;1/2" NPT, K -5.0, Chrome Finish with rosetter plate; operating temperature at 68 degC complete as required as per the technical specification.

95

-

-

... More
od108431/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage upright type sprinkler ;1/2" NPT, K -5.0, Chrome Finish; operating temperature at 68 degC complete as required as per the technical specification.

433

-

-

... More
od108432/2023_2024 : Supply, installation, testing and commissioning of 1m unbraided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc and other accessories as required as per the technical specification.

95

-

-

... More
od108433/2023_2024 : Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification.

1

-

-

... More
od108434/2023_2024 : Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 complete with all accessories as required as per the technical specification.

8

-

-

... More
od108435/2023_2024 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification.

2

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od108380/2023_2024 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

21

-

-

... More
od108385/2023_2024 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

5

-

-

... More
od108387/2023_2024 : Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

1

-

-

... More
od109170/2023_2024 : Supply, installation, testing and commissioning of Modular (Cealing mounted) ABC type extinguisher of 5Kg complete as required with all necessary accessories for successful operation as required as per the technical specification.

12

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
od108381/2023_2024 : Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke & heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

198

-

-

... More
od108386/2023_2024 : Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

8

-

-

... More
od108390/2023_2024 : Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

8

-

-

... More
od108391/2023_2024 : Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

12

-

-

... More
od108396/2023_2024 : Supply, installation, testing and commissioning of intelligent addressable Input/ Control module for monitoring and control, as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

8

-

-

... More
od108398/2023_2024 : Supply, installation, testing and commissioning of addressable relay module to automatically trigger on/off 3rd party devices like fire damper, jet fans, extract air fans etc in case of fire, complete with all accessories as required as per the technical specification. The product shall be UL listed and FM Approved.

1

-

-

... More
od108399/2023_2024 : Supply, installation, testing and commissioning of 24V Power supply unit for hooters with battery backup. The status of the power supply unit must be monitored from the FACP and alarm shall be obtained if the power supply unit fails to operate, complete in all respect with necessary accessories as required as per the technical specification.

1

-

-

... More
od108400/2023_2024 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

8

-

-

... More
od108402/2023_2024 : Supply, installation, testing and commissioning of public address and talk back system consisting of 8 zone public address cum talk back console with mike and selector, multiple channel talk back facility, power supply, battery charger, battery housing, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier, and suitable capacity battery (min 12V), etc. complete as required for meeting the technical specifications.

1

-

-

... More
od108404/2023_2024 : Supply, installation, testing and commissioning of EN/UL/FM/LPCB approved/ listed, microprocessor based intelligent addressable main fire alarm panel having suitable number of loops to connect all the devices as per BOQ in single panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to integrate with analog/digital voice evacuation system (PA-talkback system) and shall be complete with all necessary accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers.

1

-

-

... More
od108405/2023_2024 : Supply and laying of 2x1.5 sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground,on wall surface or recess as required as per the technical specifications.

2706

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

80

-

-

... More
SIGNAGES

-

-

-

... More
od108382/2023_2024 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

20

-

-

... More
od108383/2023_2024 : Supply and installation of photoluminescent glow signage for "FIRE ASSEMBLY POINT" of standard size (500*225 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

1

-

-

... More
od108389/2023_2024 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws &double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

8

-

-

... More
od108393/2023_2024 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

8

-

-

... More
od108394/2023_2024 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

4

-

-

... More
ELEVATOR WORKS

-

-

-

... More
od308453/2022_2023 : Design, fabrication, supply, installation, testing and commissioning of electric traction type with machine room , Stainless steel 26 Pax (1768 Kg) Hospital elevator with car size of 1600 mm (width) x 2400 mm (depth) (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc- except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, over load warning indicator, battery operated alarmbell, LED type emergency light, intercom suitable for hook upto Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, Automatic Rescue Device (ARD) with dry maintenance free sealed batteries, Safe landing device and Battery operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE 3 or better efficiency) of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details:-3 stops & 3 openings and entrance & exit at same side and suitable for travel height of 8.4mtrs. (Shaft Size 2400mm (width) x 3000mm (depth) ) with door opening of 1200mm (width) and 2000 mm (height) .The equipment should be BMS compatible .All components, fabrication and procedures of elevator system shall confirm to relevant IS standards/ Code and complete in all respects as per technical specifications

1

-

-

... More
od308454/2022_2023 : Design, fabrication, supply, installation, testing and commissioning of electric traction type with machine room , Stainless steel 15 Pax (1020 Kg) Hospital elevator with car size of 1000 mm (width) x 2400 mm (depth) (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc- except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, over load warning indicator, battery operated alarmbell, LED type emergency light, intercom suitable for hook upto Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, Automatic Rescue Device (ARD) with dry maintenance free sealed batteries, Safe landing device and Battery operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE 3 or better efficiency) of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details:-4 stops & 4 openings and entrance & exit at same side and suitable for travel height of 11.55 mtrs. (Shaft Size 1800mm (width) x 3000mm (depth) ) with door opening of 800mm (width) and 2000 mm (height) .The equipment should be BMS compatible .All components, fabrication and procedures of elevator system shall confirm to relevant IS standards/ Code and complete in all respects as per technical specifications

1

-

-

... More
od308455/2022_2023 : Design, fabrication, supply, Installation ,Testing and Commisioning of electric traction type with machine room, Stainless steel 250Kg capacity Dumb Waiter elevator with car inside size of 1000mm(width) x 1200 (depth) (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc. - except gst) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of minimum 0.3 Mtr/sec, electromagnetic brake system, operating panel with luminous buttons, overload warning indicator, reverse phase relay on controller, and direction indication and landings. at all floors with UP/DOWN direction, shaft wiring and lighting with accessories.The traction motor of machine room elevator shall be of gearless type and placed inside machine room complete as per technical specification. Having vertical bi-parting opening SS door with handles, stainless steel car enclosure as applicable in accordance of following details:-3 stops & 3 openings and entrance & exit at same side and suitable for travel height of 8.4 mtrs. (Shaft Size 1500mm (width) x 1200mm (depth) ) with door opening of 1000 mm. All electrical components with wiring from the single point power supply provided in machine room.Allcomponents , fabrication and procedures of elevator system shall confirm to relevant IS standards and complete in all respects as per technical specifications.

1

-

-

... More
STRUCTURED CABLING AND ACTIVE DEVICES

-

-

-

... More
od306778/2022_2023 : Supply, installation, testing and commissioning of U/UTP cable - Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification

4200

-

-

... More
od306783/2022_2023 : Supply, installation, testing and commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with fluke cable analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification

5200

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

3200

-

-

... More
od306791/2022_2023 : Supply and installation of concealed metal backbox with all accessories required at site to complete the work as per technical specification

79

-

-

... More
od306793/2022_2023 : Supply, installation, testing and commissioning of CAT6A Information Outlet, RJ45 with all accessories required at site to complete the work as per technical specification

59

-

-

... More
od306795/2022_2023 : Supply, installation, testing and commissioning of Cat6 Information Outlet, RJ45 with all accessories required at site to complete the work as per technical specification

60

-

-

... More
od306797/2022_2023 : Supply, installation, testing and commissioning of Cat6A 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification

3

-

-

... More
od306799/2022_2023 : Supply, installation, testing and commissioning of Cat6 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification

4

-

-

... More
od306800/2022_2023 : Supply, installation, testing and commissioning of Single or Dual Shuttered Face Plate with all accessories required at site to complete the work as per technical specification

79

-

-

... More
od306801/2022_2023 : Supply, installation, testing and commissioning of Cat6A Patch Cord - 2m with all accessories required at site to complete the work as per technical specification

69

-

-

... More
od306802/2022_2023 : Supply, installation, testing and commissioning of Cat6 Patch Cord - 2m with all accessories required at site to complete the work as per technical specification

83

-

-

... More
od306803/2022_2023 : Supply, installation, testing and commissioning of Cat6 Patch Cord - 1m with all accessories required at site to complete the work as per technical specification

60

-

-

... More
od306804/2022_2023 : Supply and installation of casing capping with all accessories required at site to complete the work as per technical specification

50

-

-

... More
od306805/2022_2023 : Supply, installation, testing and commissioning of covered GI unperforated cable tray with 200 mm width x 50 mm depth x 1.6 mm thickness (ISI Grade) with thread road, anchor fastener, nut, washer, etc. including all accessories required at site to complete the work as per technical specification

120

-

-

... More
od306806/2022_2023 : Supply, installation, testing and commissioning of 24 Port Stackable switch - Layer 2, 24 x 10/100/1000Base-TX ports and 2 x 10G Copper / SFP+ ports with all necessary hardware and accessories required at site to complete the work as per technical specification

3

-

-

... More
od306807/2022_2023 : Supply, installation, testing and commissioning of Core Switch - Layer 3, with min 12 x 10G Copper ports and min 4 x 10G SFP+ ports and all necessary hardware and accessories, as required at site to complete the work as per technical specification

1

-

-

... More
od306808/2022_2023 : Supply, installation, testing and commissioning of next generation Firewall having a capacity of handling 150 concurrent users with logs, monitoring, bandwidth management, security subscriptions, including software, licenses and all accessories required at site to complete the work as per technical specification

1

-

-

... More
od306809/2022_2023 : Supply, installation, testing and commissioning of 42U (800mmx1000mm) Network Rack along with all hardware and accessories required at site to complete the work as per technical specification

2

-

-

... More
IP-PBX

-

-

-

... More
od306777/2022_2023 : Supply, installation, testing and commissioning of EPABX system expandable upto 120 IP extensions, 2 PRI licenses, 2 nos of 10 channel SIP trunk licenses, including all hardware, software, 1 no of desktop based operator console and all accessories required at site to complete the work as per technical specification

1

-

-

... More
od306784/2022_2023 : Supply, installation, testing and commissioning of license of IP extensions with all accessories required at site to complete the work as per technical specification

52

-

-

... More
od306787/2022_2023 : Supply, installation, testing and commissioning of Standard IP telephone including all accessories as required at site to complete the work as per technical specification

40

-

-

... More
od306794/2022_2023 : Supply, installation, testing and commissioning of 24 Port Stackable PoE+ switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports and 2 x 10G Copper / SFP+ ports with all necessary hardware and accessories required at site to complete the work as per technical specification

3

-

-

... More
IP SURVEILLANCE

-

-

-

... More
od306782/2022_2023 : Supply, Installation, Testing & Commissioning of Enterprise Class Low-Light Network(IP) Dome type Camera having following specification:- Sensor:-1/3" CMOS progressive scan or better, Resolution:-4 MP ; Lens:-3.5-9.5 mm motorized varifocal, No. of streams:-Dual or triple stream, Min two streams fully configurable and both should support 1080p (Full HD), Min. Illumination required :-0.2Lux @(F1.6, 1/30sec) or better, B/W : 0Lux (IR LED On),Electronic Shutter Speed- (1/10~1/3000sec);WDR:- 120dB True WDR or better and should have BLC feature, Inbuilt Video Analytics : - Directional detection (Enter/Exit),Virtual line, Tampering and Motion detection, Defocus detection; Should have Smart IR LEDs with min 30m IR distance, Camera should have min 512MB RAM and min 256MB Flash, Framerate( H.265/H.264) : Min 30fps at all resolutions, MJPEG : Min 15fps at all resolutions, Should support Min 128 GB SD card . Should have IP 66/IP 67 & IK10 certification, Alarm: 1 In & 1out, Audio Compression G.711 u-law / G.726; Power:- PoE(IEEE802.3af, Class3), 12VDC or Better, Casing :- Die-Cast Aluminium , Certifications: UL, CE, FCC & RoHS compliant The cameras should have ONVIF Profile S/G/T compatability, Shoud have NDAA compliance/ GOI . Security :- HTTPS(SSL) Login Authentication, Digest Login Authentication, IP Address Filtering, User access Log -802.1X Authentication. Cameras shall not be installed with standards like - GB28181 protocols/standards or its versions and there shall be no option in the camera web page/settings to activate or deactivate such protocols/standards any of their version(s) , Preferred Make: Avigilon /TYCO /Illustra pro /Samsung Hanwha

20

-

-

... More
od306786/2022_2023 : Supply, installation, testing and commissioning of 24 port PoE+ switch - Layer 2 with 2 SFP ports with all hardware and accessories required at site to complete the work as per technical specification

1

-

-

... More
od306788/2022_2023 : Supply, Installation, Testing and Commissioning of Enterprise Class 32CH NVR; 400Mbps network camera recording band width, 8SATA HDD port and each port supports up to 10TB;Compression H.265, H.264, MJPEG, User friendly UI / UX; Should support Dynamic Event functionality and New event function of cameras should be available without software update; Resolution:- 12MP ~ CIF; Record Mode :-Normal, Dual Stream, Schedule(Continuous/Event), Event (Pre/Post), Bookmark; Event Trigger :- Alarm Input, Video Loss, Camera Event, Dynamic Event, User Event; Event Action:- e-Mail, Event Push, PTZ Preset, Alarm Out, Buzzer, Monitor Out, FTP, Shotdown; Should support min. 4 Users (Local 1, Remote 3); Simultaneous playback -Min Local 32CH, Remote 16CH per user; should support Fisheye Dewarping ; should support Date & Time, Event list, Text Search, Smart Search; Should support External iSCSI storage; Supported Protocols IPv4, IPv6, TCP/IP, UDP/IP, RTP (UDP), RTP (TCP), DHCP (Server, Client), HTTPS, SNMP, ONVIF (Profile-S); DDNS;Audio Input/Output 32 CH(network); Compression G.711, G.726, AAC(16/48KHz); Security:- IP address filtering, User access Log, 802.1x, Encryption Device certificate, Web viewer;:- should support Google Chrome, Microsoft Edge, Mac Safari; Should support min 2 HDMI( HDMI1 : 3840x2160 30Hz; HDMI2 : 1920x1080 60Hz); Audio Out (3.5mm Audio Jack); Ethernet RJ-45 (LAN/WAN, 1Gbps); Alarm In 8EA, Out 4EA; Min 2 USB( USB 3.0); NDAA Compliant or equivalent certificate as mandated by GOI. NVRs shall not be installed with standards like - GB28181, GB/T28181-2011, GB/T 28181-2011, GBT 28181- 2011, GBT28181- 2011, GB/T28181-2016, etc., protocols/standards and there shall be no option in the camera web page/settings to activate or deactivate such protocols/standards any of their version(s). Regulatory Approvals : UL BIS CE FCC., Preferred Make: Avigilon /TYCO Illustra pro /Samsung Hanwha /Axis/Mobotix/Bosch/Pelco/Honeywell/GVD - 3 Years onsite Warranty. The item shall include HDDs (min 10TB - calculation shall be submitted by the Contractor) for 30 days of archiving including an operator desktop, associated cabling and all accessories as required at site to complete the work as per technical specification.

1

-

-

... More
od306792/2022_2023 : Supply, installation, testing and commissioning of 55" commercial display 24/7 with HDMI, USB ports with all accessories required at site to complete the work as per technical specification

1

-

-

... More
ATTENDANCE SYSTEM

-

-

-

... More
od306781/2022_2023 : Supply, installation, testing and commissioning of Aadhaar based StQC approved biometric, password and proximity card based Attendance Machine, software etc. with all accessories required at site to complete the work as per technical specification

1

-

-

... More
PUBLIC ADDRESS AND EVACUATION SYSTEM

-

-

-

... More
od306780/2022_2023 : Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm

1700

-

-

... More
od306785/2022_2023 : Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required

25

-

-

... More
od306789/2022_2023 : Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required

60

-

-

... More
od306790/2022_2023 : Supply, installation, testing and commissioning of 240W power amplifier with all accessories required at site to complete the work as per technical specification

3

-

-

... More
od306796/2022_2023 : Supply, installation, testing and commissioning of PA system Controller capable of managing 6 individual zones with BGM, announcement, automatic emergency messages, integration with fire alarm system and all accessories required at site to complete the work as per technical specification

1

-

-

... More
od306798/2022_2023 : Supply, installation, testing and commissioning of Paging Microphone with multi tone chime and multi-channel zone selector for atleast 6 zones with all accessories required at site to complete the work as per technical specification

2

-

-

... More
WIRELESS ACCESS POINTS

-

-

-

... More
od306779/2022_2023 : Supply, installation, testing and commissioning of Wireless Access point, Wi-Fi 6, dual-band, 2x2 MIMO, PoE, including mounting brackets and all accessories required at site to complete the work as per technical specification

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.