KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Coronavirus COVID 19
Eprocure
Opening Date14 Aug 2018
Closing Date10 Sep 2018
Tender Amount₹ 28,71,75,601 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

967.568

-

-

... More
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia

1420

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

1194.2

-

-

... More
2.13.1.2 : Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth. including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80m dia but not exceeding 300 mm dia

70

-

-

... More
2.13.1.3 : Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth. including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia

200

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

4517.627

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

520.377

-

-

... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

9960

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

4

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

1010.171

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

107.598

-

-

... More
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

409.917

-

-

... More
4.10 : Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).

17.461

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

3301.225

-

-

... More
4.13 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

18

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

2227.768

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

4359.579

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

4212.584

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

6238.64

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

2403.425

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

2476.32

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

5

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1843.92

-

-

... More
5.9.16.2 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide

166.2

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

679.65

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

2840.403

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

25.553

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

405324.614

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

875

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge..All work upto plinth level

1548.361

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work above plinth level upto floor V level

1770.597

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC.

628.674

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

467.595

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

253.396

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

2.88

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

24.001

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

6

-

-

... More
8.12 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

1312.981

-

-

... More
8.13.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

5

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.597

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters

34.652

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters to be added to the item 2.48 ( Area of opening for glass panes excluding portion inside rebate shall be measured).

2.026

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

457.875

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

90

-

-

... More
9.72.2 : Providing and fixing bright finished brass butt hinges with necessary screws etc. complete:125x70x4 mm ( ordinary type)

54

-

-

... More
9.74.3 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:150x10 mm

24

-

-

... More
9.74.4 : Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:100x10 mm

18

-

-

... More
9.75.2 : Providing and fixing bright finished door latch with necessary screws etc. complete:250x16x5 mm

6

-

-

... More
9.81.2 : Providing and fixing bright finished brass handles with screws etc. complete:100 mm

15

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

18

-

-

... More
9.83 : Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

77

-

-

... More
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

10

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

9

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

5

-

-

... More
9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.

5

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

287.252

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

90.406

-

-

... More
9.155 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for paneled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587.

52.92

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

114.4

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

31.681

-

-

... More
9.163 : Providing and fixing non load bearing fixed frame for fire resistant glazed Partitionfor 120 min Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mmthick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for120 min of both integrity & radiation control (EW120) & minimum 15 min of insulation(EI15).The profile has to be fixed to the supporting construction by means of anchor

114.4

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

22.177

-

-

... More
9.165.2 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.100mm

22

-

-

... More
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

5.04

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

39.4

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

8

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

16

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

30.64

-

-

... More
10.19 : Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

2957.881

-

-

... More
10.25.2 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

281.625

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

9975

-

-

... More
10.29.2 : Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides

256.8

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

136.818

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

17.136

-

-

... More
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1144.149

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

2076.315

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

179.952

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

15786.099

-

-

... More
13.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

14450.945

-

-

... More
13.8.2 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1: 4 ( 1 cement : 4 fine sand)

2000.722

-

-

... More
13.10 : 15 mm cement plaster 1:3 ( 1 cement :3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.

4640.686

-

-

... More
13.11 : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ( 1 cement : 6 fine sand).

3514.651

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

6579.995

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

3866.956

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

2618.65

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

223.5

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

22028.042

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

1579

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

15806.796

-

-

... More
13.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)

3002.208

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

21472.524

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

52.457

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

33089.46

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

3.423

-

-

... More
16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

3500

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

84.555

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

923.2

-

-

... More
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

41

-

-

... More
Providing & fixing star white vitreous china flat back urinal with urinal flush valve (automatic pressing), of approved size with all accessories to provide satisfactory functioning including necessary wall cutting / chasing and making good, as required for urinal flushing etc complete, testing and commissioning to the satisfaction of Engineer in Charge as per direction of Engineer-In charge at all levels. The cost shall include cost of flush valve, necessary CP flush pipe, CP drain, spreader and all required connections.

37

-

-

... More
17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

12

-

-

... More
17.22B : Providing and fixing CP Brass Single lever telephonic wall mixer of quality& make as approved by Engineer in charge.(a) 15 mm nominal dia

22

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

42

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

30

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

80

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

200

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

300

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

300

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

300

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

200

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

200

-

-

... More
18.9.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes

200

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

200

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

300

-

-

... More
18.9.8 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work75 mm nominal inner dia pipes

20

-

-

... More
18.9.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work100 mm nominal inner dia pipes

30

-

-

... More
18.9.10 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work150 mm nominal inner dia pipes

40

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

12

-

-

... More
18.15.2 :Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms :20 mm nominal bore

12

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

6

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

12

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

6

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

18

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

10

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

8

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

4

-

-

... More
18.19.3.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreVertical

2

-

-

... More
18.19.4.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreVertical

2

-

-

... More
18.19.5.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreVertical

2

-

-

... More
18.19.6.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreVertical

2

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

14000

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

50

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve of approved quality conforming to IS: 893115 mm nominal bore

52

-

-

... More
19.4.1.1 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5

6

-

-

... More
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe

200

-

-

... More
19.6.3 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:250 mm dia R.C. C. pipe

700

-

-

... More
19.6.4 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia R.C.C. pipe

300

-

-

... More
19.6.5 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:450 mm dia R.C.C. pipe

300

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

12

-

-

... More
19.7.2.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5

15

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

10

-

-

... More
19.8.2.1 : Extra for depth for manholesSize 120x90 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

10

-

-

... More
19.18.3 : Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg

27

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

1590.639

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

1590.828

-

-

... More
21.2.1 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

10.082

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

208.802

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

58.996

-

-

... More
21.12.2 : Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50 micron aluminium tubular handle bar

21

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

77

-

-

... More
21.19.2 : Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600Upto 10 mm depth and 10 mm width

1141.702

-

-

... More
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)

690.432

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

29.508

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

1.2

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

1.2

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1.2

-

-

... More
50.2.3.1 : Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

45

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

4021.828

-

-

... More
50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.

7966

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

13.2

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

152.25

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

524.297

-

-

... More
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

825.349

-

-

... More
50.6.2.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

925.424

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

55.832

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

42

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

80

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

80

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

160

-

-

... More
50.18.9.6.2 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2

22

-

-

... More
50.18.9.7.1 : Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2

20

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

450

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

344

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

8

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

24

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

120

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

60

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

11

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

22

-

-

... More
od36056/2017_2018 : Disposal of Excavated earth/debris and other unservicable materials by manual means upto a distance of 100 m as directed by the Engineer in Charge.

32.48

-

-

... More
od38812/2017_2018 : Providing and laying of compacted fill with 10mm to downgraded metal (Coarse rubblegranite Stone) combined to form a contour and elevations to the desired level as per Drawings.Rate inclusiveof all materials,transportation and labour charges complete.The work has to be completed as per detailedspecifications and or as approved by Engineer-in-charge

175

-

-

... More
od38813/2017_2018 : Providing and laying of compacted fill with 20mm to downgraded metal (Coarse rubblegranite Stone) combined to form a contour and elevations to the desired level as per Drawings.Rate inclusiveof all materials,transportation and labour charges complete.The work has to be completed as per detailedspecifications and or as approved by Engineer-in-charge

350

-

-

... More
od38840/2017_2018 : Mixing the red earth and sand in equal quantities and adding manure in required<br>proportion etc. complete as directed by the Engineer-in-Charge.

438

-

-

... More
od38841/2017_2018 : Spreading of red earth, manure and river sand in required thickness as per direction of<br>Engineer-in-Charge. (Cost of red earth, manure and river sand paid separately).

438

-

-

... More
od38814/2017_2018 : Providing and laying of compacted fill with 40mm metal (Coarse Rubble Granite Stone)combined with a downgraded stone up to 30mm to form a contour and elevations to the desired level as perDrawings.Rate inclusive of all materials,transportation and labour charges complete.The work has to becompleted as per detailed specifications and or as approved by Engineer-in-charge

350

-

-

... More
od38815/2017_2018 : Supply and Installation of a pair of Football goal post of superior quality with nets approved by FIFA etc inclusive of all taxes (custom duty is exempted)

1

-

-

... More
od38816/2017_2018 : Providing and installing root zone, over graded and rolled subgrade include necessary trimming to form the required camber and gradients with layers of course graded medium, fine graded sand to a minimum thickness of 50mm and providing sand manure mix layer consisting of medium fine sand of U.S.G.A specification, biofibre and biosoil @10kg/sq.mtr to a minimum thickness of 150mm. Mixing the above to ensure a homogenous mix and accurate mix of components. The sand manure mix shall be compacted repeatedly by rolling to the grade & camber required and irrigating as required. The cost shall include applying pre mergence herbicide, pre plant fertilizers @10kg/sq.m to the entire area, cost of all labour, material lead etc complete as directed by the Engineer in charge.

3500

-

-

... More
od38817/2017_2018 : Supplying and Planting grass over the red earth and sand bed closely to get a thick grass lawn suitable for ground in rows of 5cm apart in both direction, keep the area moisture by spraying and sprinkling water till the grass gets sufficient deep roots cutting to level the top surface, trimming and dressing etc. complete as directed by the Engineer-in-Charge. Bermuda Grass<br>

4468

-

-

... More
od38818/2017_2018 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures. This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of joints complete for extrenal works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge.HDPE pipe 40 mm-6 kg/cm

110

-

-

... More
od38819/2017_2018 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures. This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of joints complete for external works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. & HDPE pipe 50 mm-6 kg/cm

125

-

-

... More
od38820/2017_2018 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures. This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of joints complete for external works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. & HDPE pipe 63mm-6 kg/cm

240

-

-

... More
od38821/2017_2018 : Design, supply, laying & jointing in position HDPE pipes, including all fittings and accessories and suitable for the designed working pressures. This includes jointing of pipes & fittings as per the manufacturers specifications ,trenching ,refilling & testing of joints complete as per direction of Engineer in charge -for exposed works. The work has to be executed as per approved drawings and or as directed by Engineer - in Charge. & ;HDPE pipe 90 mm-6 kg/cm

175

-

-

... More
od38811/2017_2018 : Providing and laying of 20mm downgraded metal (Coarse rubble granite Stone) of approved quality as filter media around the drainage pipes in the sides of trench as per the directions of Engineer-in-charge. Rate inclusive of all materials,transportation and labour charges complete.

96.2

-

-

... More
od38810/2017_2018 : Supplying, laying and jointing perforated HDPE pipe PE 80 of size 110 mm dia 10 kg/cm2 with 5 mm dia perforations, minimum 125 perforations per running metre, in trenches of size 35cm x 45cm at required slope, disposal of excavated earth, as per specifications etc complete including the cost of all materials, labour etc. and as directed by the Engineer-in-charge.Care should be taken while laying so that the perforations will be along the bottom of the pipe. The rate to include cost of all materials, labour charges, lead, lift etc complete.

650

-

-

... More
od36859/2017_2018 : Soling with soling stone of size 150 to 75 mm brokenstone and blinding materials, including hand packing and wedging them tightly so that the whole is formed as a solid mass, spreading blinding material in 12mm thick layers and sweeping the same to fill the voids,watering profusely and consolidating with hand rammer/ plate vibrator etc complete as per the direction of Engineer-in - Charge.

26.296

-

-

... More
od36650/2017_2018 : Supplying and fixing approved quality white vitreous china urinal division plate 700 x 340 including cost and conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by the Engineer-in-Charge.

37

-

-

... More
od36856/2017_2018 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge 150mm Dia

4

-

-

... More
od36706/2017_2018 : Providing and fixing stainless steel soap dish including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.

42

-

-

... More
od38838/2017_2018 : Providing and laying factory made chamfered edge 80mm thick Cement Concrete paver blocks of of M-30 grade with approved color design and pattern., made by table vibratory method, to attain superior smooth finish using PU or equivalent moulds,laid in required Grey colour & pattern over and including 10cm thick compacted bed of 11.2mm size crushed metal, compacting and proper embedding / laying of inter locking paver blocks into the metal bedding layer through vibratory compaction by<br>using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand ;in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per manufacturer specifications direction of Engineer -in-Charge:

4616

-

-

... More
od36691/2017_2018 : Providing and fixing enclosed type water meter (bulk type) 50mm dia conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge.

2

-

-

... More
od36693/2017_2018 : Providing and fixing Automatic Air Purge Valve (Auto Air Vent) Brass Body, Brass cover with brass body isolation socket spring loaded. etc. complete The rate including cost and conveyance of all materials, labour charges, lead, lift etc complete at all levels as directed by the Engineer-in-Charge 25mm dia

11

-

-

... More
od36704/2017_2018 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels. 75mm

30

-

-

... More
od36705/2017_2018 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.110mm

30

-

-

... More
od36713/2017_2018 : Providing and fixing coloured vitreous china counter top round wash basin 470 mm or nearest size of approved make including one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap, 15mm angle valve, etc. complete as directed by the Engineer-in-charge. (The purchase price considered for washbasin is Rs.1580, pillar cock is Rs.1100,bottle trap is Rs 1050,angle valve is Rs 550 and any deviation plus or minus in the purchase price will be adjusted in the price quoted).

41

-

-

... More
od36664/2017_2018 : Providing and fixing premium quality C.P. brass wall shower mixer with provision for overhead shower with 115mm long bend pipe on upper side,connecting legs and wall flanges of approved make and model including cost of all materials, labour etc., complete as directed by the Engineer-in-Charge at all levels.

25

-

-

... More
od36665/2017_2018 : Providing and fixing premium quality C.P. brass overhead shower 4" and wall flange of approved make and model including cost of all materials, labour etc., complete as directed by the Engineer-in-Charge at all levels.

22

-

-

... More
od36676/2017_2018 : Providing and fixing Chlorinated Polyvinyl chloride(CPVC) SDR 11 pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipes with clamps at 1.00 m spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per the direction of Engineer-in-Charge.(Concealed work including cutting chases and making good the walls etc) ;40mm nominal dia

250

-

-

... More
od36670/2017_2018 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal<br>stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the<br>pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent<br>cement and testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall;80mm nominal dia

300

-

-

... More
od36671/2017_2018 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall 65mm nominal dia

400

-

-

... More
od36678/2017_2018 : Supplying approved make PVC gully trap of size 160x110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size (inside) the weight of cover to be not less than 4.5kg and frame to be not less than 2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm, 115 thick brick wall in CM 1:6 on a foundation of PCC 1:4:8. 100mm thick plastering inside with CM 1:3, 12mm thick with a neat cement flushing coat and conveying to site, cleaning, installing and testing approved make PVC gully trap with 160mm outlet (fabricated), surrounding with CC 1:1.5:3, 150x150mmm, top with CI grating above the PVC gully trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in-Charge.

12

-

-

... More
od36855/2017_2018 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. ;150mm Dia

4

-

-

... More
od37423/2017_2018 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3HP and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels. Capacity :18m3/hr. Head : 21m

2

-

-

... More
od37424/2017_2018 : Supplying and fixing of submerssible pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels.Capacity : 18m3/hr .Head : 21 m

2

-

-

... More
od35881/2017_2018 : Supply and Installation of sand stone 18mm thick and 300mm wide for edge finishes including cost and conveyance of all material, labour, approved adhesive etc complete and as directed by the Engineer-in-charge

22.5

-

-

... More
od35882/2017_2018 : Providing and laying ceramic mosaic tiles of size 48x48mm or nearest size, including cost and conveyance of all materials, labour, glue, adhesive , water proof grout etc complete of approved make and colour as as directed by Engineer-in-charge

410

-

-

... More
od36842/2017_2018 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. 100mm Dia

4

-

-

... More
od36680/2017_2018 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge. ;100mm Dia

7

-

-

... More
od36681/2017_2018 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges, making good the walls etc complete as directed by the Engineer-in-Charge 80mm Dia

7

-

-

... More
od36682/2017_2018 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge. ;80mm Dia

7

-

-

... More
od36683/2017_2018 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer-in-Charge 65mm Dia

7

-

-

... More
od36651/2017_2018 : Providing and fixing frameless mirror, with all four edges machine polished and back side protected with safety film and 4 mm thick Plywood backing and fixed on walls with mirror screws. The rate includes lifting, cutting etc. as per design and drawing

54

-

-

... More
od36652/2017_2018 : Providing and fixing floor trap with cockroach trap (multi trap), concealed or exposed, SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels

72

-

-

... More
od36648/2017_2018 : Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-charge

70

-

-

... More
od36716/2017_2018 : Constructing soak pit 1.50x1.50x1.50 m filled with brickbats including S.W.drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

4

-

-

... More
od36712/2017_2018 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin of size 46 x 36 cms, one Hinged Rail (76 cms) & 4 numbers of Grab Rails (60cms), one number European Water Closet & Cistern complete with fittings & seat cover, etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as directed by Engineer in charge.

2

-

-

... More
od38837/2017_2018 : Supplying and stacking of good gravelly red earth brought from outside to standard heaps for measurements including transportation, loading, unloading, taxes etc complete as directed by the<br> <br>Engineer-in-Charge (earth measured in stacks will be reduced by 20% for payment).

145.201

-

-

... More
od36708/2017_2018 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>75mm OD (6 kg/cm2)<br>

80

-

-

... More
od36709/2017_2018 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>110mm OD(6 kg/cm2)<br>

160

-

-

... More
od36710/2017_2018 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>75mm OD (4 kg/cm2)<br>

24

-

-

... More
od36873/2017_2018 : Providing & fixing of acoustic wall penelling boards, size 1200x1980x25mm thk, weighing 8 to 9.3 kgs / m2, with perforated area of 9.5% and perfroations of VF8/15/20R. Sound absorption value α w upto 1.00, reaction to fire as per EN 13501-1 B-s1,d0, impact resistance as per DIN 18032 part 3 with SK-04 edges suitable for installation on the wall with the help of with 0.50 mm GI cold rolled section frame work behind as per manufacturers specifications, fixing of rockwool slab of 50mm thick with 48kg/cu mt density. Making the cut outs for HVAC grills/diffusers/service access doors, electrical appliances etc. wherever necessary. The Samples of the panel shall be submitted to the engineer-in-charge for approval.

703

-

-

... More
od36874/2017_2018 : Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with<br>suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. Contractor to make provision for fixing all electrical, networking boxes, HVAC grills etc. formed in the partition framework at required heights/levels as directed.50mm thick Rock wool insulation having a density of 48Kg/m3 shall be provided within this GI framework . The rate shall includes cost and conveyance of all materials,wrapping,labour charges,lead,lift ,etc complete as directed by Engineer in Charge. This framework shall be provided with Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm conforming to IS 2095 Part 1, having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in charge, and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.

2988

-

-

... More
12.52.4 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plaster board having glass fibre conforming to IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of 0.79, with 50 mm resin bonded glass wool backing.

6235

-

-

... More
od38805/2017_2018 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )

6490

-

-

... More
od38806/2017_2018 : Supply and fixing of seamless galvalume roofing sheet manufactured out of 0.55mm TCT colour coated cold rolled steel of 300Mpa (min) yield strength with hot dip metallic coating of minimum 150 gm/sqm Zinc Aluminium alloy coating mass (55% Aluminium, 43.5% Zinc and 1.5% Silicon) total of both sides. The colour coating shall have a total coating thickness of 35 micron silicon modified<br>polyester paint system of approved colour comprising of 20 microns of exterior coat on top surface and 5 microns reverse coat on back surface over 5 micron primer coat on both surface. The kliplock profile shall have 47mm crest height in 250mm pitch with 500mm covered width and shall be site roll formed so as to provide single length panel from ridge to eave as per site requirement. The sheet shall be press fixed over the concealed fixing clips provided on the purlins using wafer head screws.. Rate shall including cost and conveyance of all material, including all accessories, lead, lift, scaffolding, labour charges etc. complete at all levels as directed by Engineer-in -Charge. (The above work is to be carried out by a specialized agency approved by the Manufacturer and Engineer-in-Charge having experience in the laying of this type of roofing system and should ensure a warranty for a period of 5 years. Only skilled and experienced persons shall be employed for this purpose.)

6657.601

-

-

... More
od38807/2017_2018 : Providing and fixing ridge/ valley capping/flashing in required width (minimum 500 mm)<br>with plain galvalume colour coated sheet made out of 0.5mm TCT, minimum 550 MPa cold rolled steel with<br>hot dip metallic coating of Aluminium Zinc alloy (Galvalume) 150 gms/sqm,total of both sides, AZ 150 as per<br>ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials,<br>scaffolding, lead,lift, labour charges, all taxes etc. complete at all levels as directed by Engineer-in-Charge

182

-

-

... More
od38808/2017_2018 : Providing and applying 2 coats an acrylic polymer modified elastomeric cementitious water proof coating on roof slab , gutter ,OHT,SUMP etc which shall be mixed as per manufacture's technical specification, after thoroughly cleaning the surface by mechanical means to making it free of any loose mortar,unsound substrate,"V" grooves cut along the construction joints, cracks and joints of slab/wall on the external face and the same shall be filled with polymermodified mortar( CM 1:3 mixed with approved water proofing compound in the proportion recommended by the manufacturers), cracks in the slab (if any), pressure grouting wherever necessary by injecting mixed with approved expanding agent using pressure grouting pump with a pressure of 3 to 4kg/sqm ,strictly maintaining the coverage specified by the manufacturer, including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge .(The above work shall be carriedout by an agency having sufficient experience in membrane water proofing and should ensure a guarantee of 5 years. .Only skilled and experienced persons shall be employed for this purpose.)

3716.83

-

-

... More
od38798/2017_2018 : Disposal of Excavated earth/debris and other unservicable materials by manual means upto a distance of 100 m as directed by the Engineer in Charge.

1997.869

-

-

... More
od38799/2017_2018 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.<br><br>In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

5086.8

-

-

... More
od38834/2017_2018 : Supplying river sand brought from outside including transportation, loading, unloading,<br>taxes etc complete as directed by the Engineer-in-<br>Charge

231

-

-

... More
od38800/2017_2018 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, bending, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.

359034.721

-

-

... More
od38839/2017_2018 : Supplying and stacking manure brought from outside to standard heaps for measurements including transportation, loading, unloading, taxes etc complete as directed by the Engineer-in-charge& ;(Manure measured in stacks will be reduced by 8% for payment).<br>P R I C E

145.201

-

-

... More
od38801/2017_2018 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.&In gratings, frames, guard bar, ladder, railings, brackets, gates ;and similar works

4909.827

-

-

... More
od38802/2017_2018 : Structural steel work in single section, fixed with or without connecting plate including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.

3611.79

-

-

... More
od38803/2017_2018 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

631.898

-

-

... More
MEP Works for Swimming pool : PLANT ROOM EQUIPMENT FILTERS: - Supplying to Site and installing in position, Bobbin wound ,high density polyethylene material, corrosion proof , environmental safe . Unitized thermal plastic filter tank tough ,durable and suitable for many deferent weather condition 1200mm size, IN/OUT 2", with flanged connections of required size and required filter media and fitted with pressure gauge panel, manual air bleeder, water drain and emptying plug, fitted with collector and diffuser made from unplasticized PVC and polypropelene. Maximum working pressure: 2.5 kg/cm².Maximum Filtration velocity 40 m3/hr/m2. Work to be executed as per the directions of the Engineer-in-charge.Filter shall be tested at 2.5 times suction pressure. The rate to include cost of necessary valve in PVC and connected to filters as per DIN 2501 standards

2

-

-

... More
MULTI-PORT VALVE: - Supplying to Site and fixing in position, Side mounted 6-way Multi-port Valve for the filter unit. Operating Pressure 3 Bar and size 3". Made in ABS & Fibre Glass with connections including supports, brackets etc. complete. Work to be executed as per the directions of the Engineer-in-charge.

2

-

-

... More
RE-CIRCULATING PUMP Self Priming low noise pump with Built In Pre-Filter with Removable strainer, heat & chemical resistant casing with Noryl impeller & diffuser, mechanical seal, 3000rpm, Class F insulation. IP 55 PROTECTION, with shaft of stainless steel AISI 420 GRADE. Power- 5.5 HP, I/O Size-2", input voltage 230 V, Head = 18m. Rate inclsuive of all material,transportation and labour charges. Work to be executed as per the directionsof the Engineer-in-charge.

3

-

-

... More
CHEMICAL DOSING PUMP: - Supplying to Site and fixing in position Dosing Pump : With IP-55 protection. Flow Rate - 6 LPH @ 4 kg./cm2 with Chemical storage tank made of HDPE of 100 Litres capacity (One for Chlorine and the other for pH correction).Work to be executed as per the directionsof the Engineer-in-charge.

2

-

-

... More
POOL BASIN EQUIPMENT POOL DRAINS: - Supplying to Site and fixing in position,ABS Square Drain/Round Main Drain with cover.

4

-

-

... More
Supply & installation of ABS inlets: Suction inlets with Vacuum fittings of size 2 inches.

4

-

-

... More
Supply&installation of puddle flanges to arrest leak. Wall conduit /UPVC puddle flange in PVC, 500 mm long.

33

-

-

... More
Supply & installation of ABS Wall Inlets of size 2 inches .

25

-

-

... More
FLOOR INLETS: - Supplying to Site and fixing in position, Floor Inlets with regulable flow. Made in ABS with SS screws. Maximun flow per Inlet - 7,500 LPH.

20

-

-

... More
SUCTION NOZZLE: - Supplying to Site and fixing in position Suction Nozzle made in ABS. With plug. With 2" male thread connections.

4

-

-

... More
Deck Boxes: Supply & Installation of Deck boxes, connection box in ABS & waterproof, size : 18x18.

12

-

-

... More
Pool overflow channel drain:Supply & installation of pool overflow channel drain.

25

-

-

... More
Over Flow gratings:Supply, installation of overflow gratings, molded in white UV resistant ABS, top of grating features an anti-slip finish and it is composed of individual units connecting along a central spine

50

-

-

... More
POOL LADDER Supplying to Site and fixing in position, In SS 304 with Handrails of dia 43mm with non-slip safety steps & anchoring fixtures. Suitable for Pool Depth of 1.2/1.35meters. No. of Steps - 3 or 4. Work to be executed as per the directionsof the Engineer-in-charge.

4

-

-

... More
MAINTENANCE EQUIPMENT Supplying to Site and fixing in position, Suction Head Made in Anodised Aluminium. Connections: 1 1/2" & Length: 350 mm.

1

-

-

... More
Supplying to Site and fixing in position, Telescopic Re-inforced handle in anodized aluminium. Length: 10 meter .

1

-

-

... More
Supplying to Site and fixing in position, Floating Suction Hose : Plastic hose, 1 1/2" dia & 30 meters long including hose cuffs for connection to suction sweeper

1

-

-

... More
Supplying to Site and fixing in position, 18" Curved Cleaning Brush.

1

-

-

... More
Supplying to Site and fixing in position, Algae brushes with stainless steel bristles.

1

-

-

... More
Supplying to Site Test kit for free chlorine & pH .

1

-

-

... More
Competition Equipment:Supply, installation of competition blocks 700mm height.

5

-

-

... More
Supplying and fixing in position steel horizontal anchoring

8

-

-

... More
Supply and fixing ROME model float line long-FINA approved.

4

-

-

... More
Supply and fixing Storage reel -FINA approved.

1

-

-

... More
Supply and fixing line rope hook -FINA approved.

8

-

-

... More
Supply, installation of all Pipes ( PN 10 grade) and its fittings ( PN 16 Grade)

1

-

-

... More
Supplying & fixing of centrofugal pump, with CI construction, CI impeller complete with motor, base plate, etc and working with 415V,3ph and 50 Hz frequency. Capacity : 1HP Pump @ drain in plant room

1

-

-

... More
TESTING AND COMMISSIONING:- Supplying and filling water in the pool for testing and commissioning including the cost of water, conveyance etc., including startup chemicals. complete as per the directions of Site-in Charge.

400

-

-

... More
PART-A ELECTRICAL PANELS ELECTRICAL WORK Design,Supply, installation, testing and commissioning of outdoor duty (IP 54) pedestal mounted type weatherproof ,double door type KSEB metering panel , suitable for accomodating KSEB energy meter ( supply of energy meter is under KSEB scope) and consisting of 3 nos. of 125A HRC Fuse base with HRC fuses, 3 nos of 75/5A CTs Class 0.5 CT (or as per KSEB) ,3 nos of 2A SP MCB ,inter connections , providing necessary supports made from the same gauge CRCA sheet to fix energy meters, etc . and to be fabricated out of 16 SWG MS sheet with locable door having glass window, sealing facility for KSEB, top cover and necessary overhang, undergone seven tank process ,powder coated finish and all mounting accessories as required complete with civil foundation.The panel shall be with all accessories as per specification.

1

-

-

... More
MSB Supply, installation, testing &commissioning of totally enclosed free standing floor mounting dust & vermin proof indoor cubicle type IP42 panel board suitable for 415V, 3 phase, 50Hz supply with provision for fixing incoming & outgoing switches fabricated using 2 mm MS sheet powder coated with necessary cable alley & bus bar chamber for all switches. The panel shall be with all accessories as per drawing & specification. (Refer particular specification). Incomer 200 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 5nos. Din type HRC fuse unit, neutral link etc. - 1No. 4A, C curve SP MCB - 3 nos. RYB indication lamp, LED type - 3 nos. (0-500)V voltmeter, Acc. class 1 with 90 deg defl. scale - 1 no. (0-200)A ammeter Acc. class 1 with 90 deg defl. scale - 3 nos 6A 3 pole voltmeter selector switch - 1 no. 200/5A 5VA class 1 resin cast CT - 1 set The panel shall be provided 1set 200/5A, 10VA, class 1, CT for APFC relay for capacitor panel 200A TPN busbar chamber with Aluminium busbar. Outgoing 100 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1no,63 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1no.40 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 8nos.

1

-

-

... More
Outdoor Lighting Panel (ODP) Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type, totally enclosed, IP 54, free standing, floor mounting, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply with provision for fixing incoming & outgoing switches fabricated using 2 mm CRCA sheet powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc., The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) including following switchgears accessories for the LT Panel INCOMER Surge Arrestor Type 1+2 Combination- 1 Set 40 A, FP, MCB - 1 No BUSBARS 40 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy - 1 Set INSTRUMENTS 4A, C curve SP MCB - 3 Nos. RYB indication lamp, LED type - 1 Set Voltage Surge Protector-1 Nos 24 hrs Digital time switch with inbuilt battery - 8 Nos. 25A, AC-1 contactor -8 Nos OUTGOINGS 16 A, FP RCCB (100mA)-8Nos 16 A C Curve FP MCB-8 Nos

1

-

-

... More
PART B WIRING AND ACCESSORIES Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

369

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

24

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

800

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

4500

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

1500

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch and socket

38

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch and socket

16

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

3

-

-

... More
Supplying and fixing 3 Module (100mm X 75mm), GI box without modular base & cover plate for modular switches in recess etc as required.

16

-

-

... More
Supplying and fixing 3 Module Modular base & cover plate on existing modular metal boxes etc. as required.

16

-

-

... More
Supplying and fixing 6 Module (200mm X 75mm), GI box without modular base & cover plate for modular switches in recess etc as required.

38

-

-

... More
Supplying and fixing 6 Module Modular base & cover plate on existing modular metal boxes etc. as required.

38

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

58

-

-

... More
PART C LIGHT FIXTURES AND FANS Supply of pre-wired,18W LED Batten fitting complete with all accessories and tube etc. including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

152

-

-

... More
Supply of decorative surface wall mounting slim flurescent type fixtures suitable for 10W T5 lamp including electronic ballast prewired complete as required

69

-

-

... More
Supply of LED down light made of die cast aluminium, along with driver,system wattage maximum of 12 Watts, power factor 0.9,rated life of L70 @ 40,000 hours, system efficacy greater than 50lumen/watt and including all necessary accessories as required complete.Make:WIPRO LD80-101-XXX- 60-XX or equivalent approved make

148

-

-

... More
Installation, testing and commissioning of prewired flourescent/ CFL/ LED fitting of all types complete with all accessories and fluorescent lamps of all types directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheatherd round copper conductor flex wire or extending the original wiring and giving connections as required.

369

-

-

... More
Supply of LED down light made of die cast aluminium, along with driver,system wattage maximum of 12 Watts, power factor 0.9,rated life of L70 @ 40,000 hours, system efficacy greater than 50lumen/watt and including all necessary accessories as required complete.Make:WIPRO LD80-101-XXX- 60-XX or equivalent approved make

51

-

-

... More
Installation, testing and commissioning of prewired flourescent/ CFL/ LED fitting of all types complete with all accessories and fluorescent lamps of all types directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheatherd round copper conductor flex wire or extending the original wiring and giving connections as required.

568

-

-

... More
UNDERWATER LIGHTS Supplying to Site and fixing in position Underwater 7w/12v LED wall hung light

12

-

-

... More
JUNCTION BOXES Supplying to Site and fixing in position, Junction Box : In ABS with 3 entries of 3/4" or PG-16 coupling Make: ASTRAL (Spain) / Equivalent

12

-

-

... More
TRANSFORMERS Supplying to Site and fixing in position, Step-down Transformer : 300 VA / 220V - 12V

2

-

-

... More
TRANFORMER PROTECTION BOX Supplying to Site and fixing in position transformer protection box

2

-

-

... More
Supply of Ventilair DXW-Neo (250mm) Exhaust Fan suitable for operation on single phase 230V ,50Hz AC supply complete with all accessories as required complete.(Make crompton,Havells, Philips or equivalent approved make)

51

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.

51

-

-

... More
Supply, conveyance, installation,testing and commissioning of ceiling fan,using standard accessories excluding speed regulators suitable for 230 V/240 V 50 HZ, AC supply wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100 v grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. confirms to IS 374/1979 as required complete.

58

-

-

... More
Supply, installation, testing and commissioning of LED Flood light luminaire of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage less than 250 (+/-5)W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens not less than 4500 and system efficiency greater than or equal to 110 lumens/Watts or above @ PF ≥ 0.95.The Light fitting shall be with all required accessories suitable for mounting in (48-60)mm OD pole arm. The luminaire should meet all the technical specifications as mentioned. (Make: Make: LT T25057F0X0 or equivalent approved make)

98

-

-

... More
Supply, installation, testing and commissioning of LED Flood light luminaire of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage less than 200 (+/-5)W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens not less than 4500 and system efficiency greater than or equal to 110 lumens/Watts or above @ PF ≥ 0.95.The Light fitting shall be with all required accessories suitable for mounting in (48-60)mm OD pole arm. The luminaire should meet all the technical specifications as mentioned. (Make: Make: LT T20057F0X0 or equivalent approved make)

15

-

-

... More
PART D DB's AND ACCESSORIES Supplying and fixing of 6 ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

1

-

-

... More
Supplying and fixing 8 way (4 + 24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

2

-

-

... More
Supplying and fixing 6 way (4 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

1

-

-

... More
Supplying and fixing 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

1

-

-

... More
Supplying and fixing 5 amps to 32 amps rating,single pole, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

57

-

-

... More
Supplying and fixing 5 amps to 32 amps rating,triple pole, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

51

-

-

... More
PART E CABLES & CABLING Supply of 3.5C 120 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

400

-

-

... More
Supply of 4C 25 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

500

-

-

... More
Providing and fixing 10 SWG dia copper on surface or in recess for loop earthing along with existing cable as required.

53

-

-

... More
Supply of 4C 16 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

250

-

-

... More
Supply of 4C 4 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

4500

-

-

... More
Supplying and making end termination with brass compression gland and aluminium/Copper lugs for 4C 25 Sq.mm Al XLPE insulated PVC sheathed aluminium conductor cable of 1.1 kV grade as required.

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium/Copper lugs for 3.5C 240 Sq.mm Al XLPE insulated PVC sheathed aluminium conductor cable of 1.1 kV grade as required.

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium/Copper lugs for 3.5C35 Sq.mm Al XLPE insulated PVC sheathed aluminium conductor cable of 1.1 kV grade as required.

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium/Copper lugs for 4C16 Sq.mm Al XLPE insulated PVC sheathed aluminium conductor cable of 1.1 kV grade as required.

8

-

-

... More
Supplying and making end termination with brass compression gland and aluminium/Copper lugs for 4C 4 Sq.mm Al XLPE insulated PVC sheathed aluminium conductor cable of 1.1 kV grade as required.

36

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of upto 35 sqmm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

5200

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 185 & upto 400 sqmm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

350

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of upto 35 size on wall surface as required.

875

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of above 185 & upto 400 size on wall surface as required.

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of upto 35 sqmm size in the existing RCC/ HUME/ METAL pipe as required.

50

-

-

... More
PART F EARTHING AND ACCESSORIES Earthing with C.I. earth plate 1.2 meter * 1.2 meter, 12.5 mm thick including all accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required.

8

-

-

... More
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 25mm X 6mm GI

500

-

-

... More
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 3.15mm Cu (10 SWG)

5000

-

-

... More
Fire fighting Supplying, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a) Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2280 lpm at 70m. head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

1

-

-

... More
Supplying, Installation, Testing and Commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a) Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2280 lpm at 70 m. head conforming to IS 1520. (b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment,2x12v 180AH Batteries and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity 300 Litres) with level indicator, By-pass line,MS Piping to diesel tank from engine, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.

1

-

-

... More
Supplying, Installation, Testing and Commissioning of electric driven pressurisation pump ( Jockey Pump )suitable for automatic operation and consisting of following: complete in all respect as required as per the technical specification. (a)Horizontal type, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 70 m. head conforming to IS 1520. (b) Suitable HP Squrrel cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads .

1

-

-

... More
Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 - 14 Kg ) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required as per the technical specification.

3

-

-

... More
Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required as per the technical specification.

3

-

-

... More
Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required as per the technical specification.

1

-

-

... More
Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 and 1239 including all drop forged fittings and accessories like elbows, tees, flanges, tapers, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc as required. The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on the wall,ceiling,truss etc for all heights with suitable hangers/supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

-

-

-

... More
200 mm dia

7

-

-

... More
150 mm dia

47

-

-

... More
100 mm dia

393

-

-

... More
80 mm dia

234

-

-

... More
65 mm dia

63

-

-

... More
50 mm dia

126

-

-

... More
40 mm dia

193

-

-

... More
32 mm dia

36

-

-

... More
25 mm dia

439

-

-

... More
Supply, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589 / 1239 including drop forged fittings like elbows, tees flanges,reducers, tapers, nuts bolts, gaskets etc. conforming to IS standards in ground at minimum depth of 1 m, including excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating minimum 4 mm thickness as per IS10221, refilling the trench etc. of following sizes complete as required as per the technical specification.

-

-

-

... More
150 mm dia

515

-

-

... More
100 mm dia

179

-

-

... More
80 mm dia

9

-

-

... More
Supply, installation, testing and commissioning of dual plate non-return valve of following sizes conforming to IS : 5312 complete with CI body, rubber gasket, GI bolts, nuts, washers etc. as required as per the technical specification.

-

-

-

... More
150 mm dia

5

-

-

... More
100 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
50 mm dia

3

-

-

... More
Supply, installation, testing and commissioning of butterfly valve PN 16, with Cast iron body, Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required as per the technical specification.

-

-

-

... More
200 mm dia

1

-

-

... More
150 mm dia

9

-

-

... More
100 mm dia

9

-

-

... More
80 mm dia

4

-

-

... More
65 mm dia

6

-

-

... More
50 mm dia

4

-

-

... More
40 mm dia

4

-

-

... More
Providing, Installation, testing and commissioning of swing type Foot valve with CI body, strainer of following size confirming to IS specifications complete with gaskets, seal and accessesories as required as per the technical specification.

-

-

-

... More
150 mm dia

2

-

-

... More
80 mm dia

1

-

-

... More
SITC of priming tank of capacity 1500 lit. made of HDPE material with outlet/ inlet connection, water level indicator, over flow arrangement, float valve, etc. completed as required as per the technical specification.

1

-

-

... More
Supply,installation,testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,Chain etc complete as per the technical specification.

24

-

-

... More
Supplying and fixing First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete as per the technical specification with the following as required. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe

16

-

-

... More
Supplying and fixing 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required complete as per the technical specification.

48

-

-

... More
Supplying & fixing 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required complete as per the technical specification.

24

-

-

... More
Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.

12

-

-

... More
Supply, installation, testing and commissioning of Fire brigade collective breaching with 4 nos. of 150 mm flanged out let connection and built in check valves complete as required complete as per the technical specification.

3

-

-

... More
Supply, installation, testing and commissioning of Air release valve 25 mm dia complete as required as per the technical specification.

5

-

-

... More
Supply, Installation, Testing and Commissioning of 100mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, GI pipe of required size, flanges, orifice plate, gasket etc. complete as required complete as per the technical specification.

2

-

-

... More
Providing, fixing, testing & commissioning of sprinkler of the following type complete as required as per the technical specification : Standard response, standard coverage sprinkler, pendant type sprinkler ;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C.;including cost of rosette plate

227

-

-

... More
Standard response, extended coverage horizontal sidewall sprinkler;1/2" NPT, K -11.2, Chrome Finish; operating temperature at 68 deg. C.

90

-

-

... More
Supply, installation, testing and commissioning of 1m unbraided flexible drop to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible drop with nipple, reducer, square bar and brackets etc complete as required as per the technical specification.

80

-

-

... More
Supply, installation, testing and commissioning of UL listed flow switch which shall be of Paddle type with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The material of the construction of the paddle shall be of stainless steel or copper alloy. The body of the flow switch shall be water proof with IP55 class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 15Kg/cm2 and operating pressure ranging from 3.5kg/cm2 to 10Kg/cm2. It shall be complete as required as per the technical specification

14

-

-

... More
TOTAL OF HYDRANT & SPRINKLER SYSTEM Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2006 with ISI mark complete as required as per the technical specification.

18

-

-

... More
Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas complete as required as per the technical specification.

2

-

-

... More
Supply and installation of Mechanical foam extinguisher of ISI marked 9 litres capacity complete in all respects including initial fill. The Extinguisher should be manufactured and perform strictly as per IS: 15683:2006 complete as required as per the technical specification.

2

-

-

... More
Supply and installation of Water mist extinguisher of ISI marked 4 Kg capacity complete in all respects including initial fill. The Extinguisher should be manufactured and perform strictly as per IS: 15683:2006 complete as required as per the technical specification.

8

-

-

... More
Supply, installation, testing and commissioning of Addressable type Multi Detector (photoelectric cum rate of rise temperature type) complete with all accessories like base. base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. Shall be UL listed/ FM Approved, complete as required as per the technical specification.

102

-

-

... More
Supply, installation, testing and commissioning of addressable type heat detector complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. Shall be UL listed/ FM Approved, complete as required as per the technical specification.

5

-

-

... More
Supply, installation, testing and commissioning of Addressable type Manual Call Point Re-setable type via special key (non-breaking glass type)complete with push button, enclosed in box with provision for cable or conduit coupling. The unit to be painted fire red outside, white inside and having illustrations of operational instructions in case of fire. Shall be UL listed/ FM Approved, complete as required as per the technical specification.

18

-

-

... More
Supply, installation, testing and commissioning of loop powered wall sounder beacon at different locations complete for both audio and visual indication with all fixing accessories, etc. under false ceiling, roof, wall, etc, with a time delay of max 30sec, interconnecting lo loop cable complete as required. Shall be UL listed/ FM Approved, complete as required as per the technical specification.

18

-

-

... More
Supply, installation, testing and commissioning of Addressable/Conventional type with addressable module reflected beam smoke detector with protection range upto 100m complete with transmitter,receiver, reflector, brackets and all other necessary accessories. The product must be UL listed and FM approved,complete as required as per the technical specification.

8

-

-

... More
Supply, installation, testing and commissioning of addressable Loop Isolators to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required. Shall be UL listed/ FM Approved, complete as required as per the technical specification.

11

-

-

... More
Supply, Installation, Testing & Commissioning of 16 bit intelligent Addressable Fire Alarm Control Panel with suitable number of loops ( each loop accessing at least 250 detectors ) including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module and fire device loop interface cards for indicating devices and should also be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches when ever any Alarm is triggered.The panel shall have 54 Ah SMF Battery, Keypad operation, L C D unit to indicate Fire / Fault Signal of individual unit,etc complete in all respects. The panel shall be UL listed/ FM Approved,complete as required as per the technical specification.The Panel shall also have Logic hardware and software built into it for time delay operation of hooter and others as follows : (a) programming software for the system (b) automatic system test activates (c) detector sensitivity adjustments (d) alarm verification (e) Alpha/numerical display (f) provision to connect to PCs and external printers

1

-

-

... More
Supply, installation, testing and commissioning of intelligent addressable Input module for monitoring purpose and send the signal from a flow switch to the alarm panel for initiating alarm when flow occurs. Shall be UL listed/ FM Approved, complete as required as per the technical specification.

14

-

-

... More
Supply, installation, testing and commissioning of addressable relay modules to automatically trigger on/off devices like jet fans, AHU, extract air fans etc in case of fire. The product must be UL listed and meeting technical specification.

16

-

-

... More
Supply, installation, testing and commissioning of addressable duct detectors for detecting smoke inside the return air duct with sampling tube and other accessories complete as required. The product must be UL listed and meeting technical specification.

10

-

-

... More
Supply, installation, testing and commissioning of LED Response indicator for all detectors located above false ceiling with low profile, white case and shall not exceed 2.5 inches of extension below the finish ceiling, complete as required as per the technical specification

25

-

-

... More
Supply, installation, testing and commissioning of addressable type 24v Power supply unit for hooters with battery backup, complete as required as per the technical specification. The status of the power supply unit must be monitored from the FACP and alarm shall be obtained if the power supply unit fails to operate.

4

-

-

... More
Supply, installation, testing and commissioning of Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept / reset buttons for alarm address of any sensor / field device. The Repeater Panel shall only provide field device address with room number. Analogue Output is not required. The Panel shall be connected to the Fire Alarm Panel. Shall be UL listed/ FM Approved, complete as required as per the technical specification.

2

-

-

... More
Supply and laying of 2x 1.5sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above ground, on walls and ceilings etc. complete as required as per the technical specification.

2270

-

-

... More
Supply and laying of 25mm dia PVC conduit along with accessories like PVC bends,couplers,junction box,fastners, iron staples/saddles/screws,in surface/ recess including cutting the wall/ceiling and making good the same in case of recessed conduit etc. complete as required as per the technical specification.

179

-

-

... More
CO2 Liner heat detection/trace tube PANEL/modular FLOODING SYSTEM FOR ELECTRICAL PANELS consisting of CO2 cylinders with weight calculated on the basis of volume of single largest compartment within the panel. UL listed trace tube of required design length, for the following size of cylinders, also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessories of complete functionality of system, complete as required as per the technical specification. 4.5Kg

1

-

-

... More
CO2 Liner heat detection/trace tube PANEL/modular FLOODING SYSTEM FOR ELECTRICAL PANELS consisting of CO2 cylinders with weight calculated on the basis of volume of single largest compartment within the panel. UL listed trace tube of required design length, for the following size of cylinders, also consisting of master control unit with digital display, load cell, discharge hooter/flashers, pressure gauges, pressure switches for low pressure/discharge indications & interlocks with fire alarm system of the premises & all accessories of complete functionality of system, complete as required as per the technical specification. 9.0 Kg

1

-

-

... More
Supply, installation, testing and commissioning of public address and talk back system consisting of 6 zone public address cum talkback console with mike and selector. 6 channel talk back master control panel with 2x16 character LCD display,power supply, battery charger, battery housing, 80 W PA & mic, 6 channel selector with all call and mic on. The console shall be provided with suitbale capacity amplifier (min 80W) and suitable capacity battery (min 12V) all assembled in a cabinet and meeting the technical specifications. The rate shall include the cost of all the necessary accessories as required for the operation of the system, complete as required as per the technical specification.

1

-

-

... More
Supply, installation, testing and commissioning of wall mounted talk back unit including all necessary accessories complete as required as per the technical specification.

16

-

-

... More
Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

16

-

-

... More
Supply and installation of glow signage (photoluminescent)of "3M" Make such as Fire Duct/Fire Lift/Staircase signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification

32

-

-

... More
Supply and installation of glow signage (photoluminescent)of "3M" Make FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification

2

-

-

... More
Supply and installation of glow signage (photoluminescent)of "3M" Make "FIRE ORDER" of standard size (500*800 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification

8

-

-

... More
Supply and installation of glow signage (photoluminescent)of "3M" Make such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

14

-

-

... More
Supply and fixing of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwitched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification.

8

-

-

... More
Main Fire Pump Panel Supply of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with bus bars extendable on both sides, including all the necessary internal wiring , suitable spreader etc. The panel shall be fabricated from a firm having CPRI certification with test certificates (required for short circuit rating, temperature rise test and IP classification) with following switchgears, metering instruments and accessories etc.complete in all respect as per drawing and technical specification. The panel shall be with top entry to receive incoming & outgoing cable, all necessary interconnection & accessories as per particular specification & single line diagram. INCOMER: 120A, FP, MCCB Isolator - 1 No. INSTRUMENTS (0 to 500 )V analogue type Voltmeter for 3 phase, 4 wire operation with selector switch - 1 set, (0 to 150A) analogue type ammeter for 3 phase, 4 wire operation with selector switch - 1 set, Phase indicating lamps, LED type, RYB - 1 Set, ON, OFF, Trip indicating lamps, LED type, RYB with 3 nos. control SP MCB - 1 Set, 120/5A, Class 1.0, 15VA, Cast Resin CT for metering - 1 Set, BUSBARS:100 Amp TPN bus bars of high conductivity electrolytic quality Aluminium alloy. OUTGOING: Electrical Fire Pump, 100A, TP, MCCB Isolator - 1 No. , Star Delta starter of suitable rating for 415V, 50Hz, 3 phase for main electrical fire pump(approx. 45 kW) with kW in accordance with the main electric pump. The starter shall have ON, OFF push button, ON, OFF indication lamp complete with all accessories and internal wiring required for automatic and manual operation as required. - 1 No's , Jockey Pump- 1 No, 40A, TP, MCCB Isolator - 1 No., Star Delta starter of suitable rating for 415V, 50Hz, 3 phase Jockey pump (approx. 11KW). The starter shall have ON, OFF push button, ON, OFF, Trip LED indication lamp, thermal over load relay, single phase preventer, complete with all accessories and internal wiring required for automatic and manual operation - 1 No , 63A, TP+NL, MCB for Battery Charger - 1 No. Spare: 100A, TPN, MCCB Isolator - 1 No. , 63A, TPN, MCCB Isolator - 2 Nos. , Diesel Engine Control - 1 No. , Each Diesel engine control consisting of: 25A DP C curve control MCB, 25A On/off control switch - 2 No. , Auto / manual selector switch, 3 attempt starting device, push button etc., All required timers, relays, fuses and accessories for automatic operation of diesel engine. Indication lamp for high water temperature, engine fail to start, engine On indication, high/low lube oil pressure. Necessary control wiring for start / stop solenoid, line / oil pressure switch, temperature switch, pressure switch to fire pump panel, diesel engine control panel to fire pump panel etc. Battery Charger suitable for 12 V / 24 V DC with boost and trickle selector switch, 0 -15 V / 0 - 30 V DC volt meter, 0 - 20 A DC Ammeter - 02 No. 6 panel annunciation window for fault indication with hooter, accept & reset push button, separate hooter for Diesel /electrical pump on running condition - 1 No The system shall include all accessories to control the operation of main electric pump, diesel pump, jockey pump as per the operating sequence for the fire fighting system indicated in the technical specification . The battery charger and all its components should be housed inside the main fire pump pane The Scope of works also includes LT power & control cabling including the GI ladder type cable tray & necessary MS supports.etc complete in all respects as per technical specification

1

-

-

... More
CABLES AND CABLING Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date, complete in all respects as per technical specification. 3.5C 70 Sq.mm Al

50

-

-

... More
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date, complete in all respects as per technical specification. 3.5 C 35 Sq.mm Al

25

-

-

... More
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date, complete in all respects as per technical specification. 3C 10 Sq.mm Al

300

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete in all respect as per technical specification.3.5C 70 Sq.mm Al

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete in all respect as per technical specification.3.5 C 35 Sq.mm Al

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete in all respect as per technical specification.3C 10 Sq.mm Al

2

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc complete in all respect as per technical specification.Upto 35 sq. mm

25

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc complete in all respect as per technical specification.Upto 35 sq. mm

25

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface complete in all respect as per technical specification.Upto 35 sq. mm (clamped with 1mm thick saddle)

225

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface complete in all respect as per technical specification.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

70

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe complete in all respect as per technical specification.Upto 35 sq. mm

25

-

-

... More
EARTHING Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc.complete in all respect as per technical specification (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)50x6 GI Strip

25

-

-

... More
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc.complete in all respect as per technical specification (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)25x6 GI Strip

510

-

-

... More
SPRINKLERS & ACCESSORIES Supply,Fixing&CommissoningofPopupsprinklerfull/partcirclehavingradiusofthrow15m-23m&flowof0.09-0.61ltr./sec.atanoperativepressureof2.5-4.5kg/cm.sq.,Thesprinklerisgeardrivenrotarytypewithslipclutchmechanismandheavydutyretractspring.memoryarc,nonstrippableandbrassreinforcednozzleturret,leftrightbothsidearcadjustment,Memoryarctechnology,partandfullcircleinsamesprinkler.Thesprinklershallhavemulti-function,pressure-activatedwipersealforlowpressureopreationaThesprinklershallhaveinternalSeal-A-Maticdevicewhichpreventslowheaddrainage(upto3.1m)&hencepuddling&erosion.Thebodyofsprinklerisofnon-corrodible,heavyduty,ABSplastic.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.

24

-

-

... More
Supply,Fixing&CommissoningofSodCupKitallowsuserstogrowturfonthecapoftherotors.Thisallowsforanearlyinvisibleinstallationforapplicationssuchassportsfields.TheruggedconstructionoftheCupKitprovidesmaximumdurabilitywhilemaintainingmaximumplayersafety.Integralpullupslot.Easyarcadjustmentafterinstallationthroughinnercup.Drainholestopromotehealthyturfgrowth.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterials,fittings,labour,transportationcomplete. engineering plastic

24

-

-

... More
Supply,Fixing&Commissoningof1"PopupConnectingSwingjointAssembly.ThetubingshallbemadeofUPVC,aworkingpressureof5.5kg/cm2at43oCandasurgepressureof16.6kg/cm2.ThefittingsshallbemadeofUVresistantthermoplastic.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-incharge.Rateinclusiveofallmaterials,fittings,labour,transportation complete.

24

-

-

... More
Supply,Fixing&CommissoningofHDPEservicesaddleofvaryingsizewithpressureratingofPN10.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-incharge.Rateinclusiveofallmaterials,fittings,labour,transportation complete.

24

-

-

... More
VALVES & ACCESSORIES Supply,Fixing&CommissoningofPVCBallValve,securitypivottomaintainleverinspace,doublewatertightjoint,directinjectionstem,nonmechanical,withabasewhichpermitsmaximumpenetrationintothevalveofsize63mmwithpressureratingPN10.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterials,fittings,labour,transportation complete.

6

-

-

... More
Supply,Fixing&Commissoningofadoubleacting1/2"Airreleasevalve,madeofHDPEorhighergradematerial.TheAirreleasevalveshallbecapableofbothreleasingandadmittingairfromandintotheline.Theworkingpressureshallbe5bar.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterials,fittings,labour,transportation complete.

4

-

-

... More
Supply,Fixing & Commissoning of 12" Rectangular Valve Box made of HDPE or higher grade material, with green lid and corrugated structure with unique shovel access slot and bolt hole knockout. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.

6

-

-

... More
Supply,Fixing & Commissoning of 6" Round box of HDPE or higher grade material, with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.

6

-

-

... More
Supply,Fixing & Commissoning of 1.5 inch quick coupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete

3

-

-

... More
Supply,Fixing & Commissoning of brass key threads into top of quick coupling valve to provide water access. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials,fittings,labour,transportation complete.

3

-

-

... More
FILTERATION UNIT Supply,Fixing&Commissoningof3"DiscFiltermadeofHDPEhavingansuitableinletconnections,tocreateahelicaleffectintheincomingwater,spinningparticulateinsuspensionawayfromthefilteringelementandsominimizingcleaningsfrequency,3/4"outletforflushingatbottomoffilter&maximumworkingpresureof12Bars.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterials,fittings,labour,transportation complete.

1

-

-

... More
PUMPING UNIT Supply,Fixing & Commissoning of Monobloc or openwell submercible pumpset of having discharge and head of design flow . Duty of Pump : 6.50 lps / Each Pump Pressure Head Range = 55 - 60 Mtr No.ofPumps:1Working+0Standby/.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterials,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing&CommissoningofcontrolpanelsuitableforpumpsethavingpanelboxmadeofCRCAsheetof2mmthicknessandfixedalongwithfollowingaccessoriesDOLstarter,start/stoppushbuttons,Ammeter,Singlephasepreventor,Voltmeter,Indicatinglamps,MCB,Drylevelguardsensorwithcontrolcable,etc.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterialsofapprovedmake,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing & Commissoning of Suction ,Delivery & Header Pipes of size suitable for the pump flow ( ASTM sch 40/80 or PVC 10Kg/cm2). Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete

1

-

-

... More
Supply,Fixing & Commissoning of CI control Valve, Butterfly Valve in mainline for bypass and flow diversion of approved quality with pressure rating of PN 10. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing&Commissoningof2"gunmetalNonReturnValvePN10withallaccessoriestopreventbackflow.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterials of approved make,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing&CommissoningofPVCPressurereleasevalve2"withallaccessories.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterialsofapprovedmake,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing&CommissoningofCastIronPaddleWheelWaterMeterMetalFlangedofpressurerating10Barwithallaccessories.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusive of all materials of approved make,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing & Commissoning of 14 Awg cable with high molecular weight polyethelene and applications upto 600volts , temperature upto -55 to+ 60 deg centigrade ,soft drawn bare copper meeting ASTM B3, tensile strenth 1400PSI for two way communication betwee nsolenoid valvel and decoders complete .Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.

580

-

-

... More
Supply,Fixing & Commissoning of ASTM Station Modular Controller UV resistant,wall mount case,with LCD display ,non volatile memory for 100years,10KV surge protectionwith removable front panel and programmable under battery in office,total run time calculator ,short detect errors,one touch watering,wityh contract default programe s,slow closing valve removable battery with sensor terminals Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing & Commissoning of 3" Solenoid globe Valves as central shut off valve with fabric reinforced diaphram and rugged PVC construction ,compatible and slow closing to prevent water hammer,pressure rating upto 0,7 to 10 bar and maximum flow of 10 to 100 m3/h ,max water temp. upto 60°C with 24 VAC - 50 Hz,coil resistance 30ohm with provision to attach Pressure Regulating Module (Dial). Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.

1

-

-

... More
Supply, Fixing & Commissoning of 2" Solenoid globe Valves with fabric reinforced diaphram and rugged PVC construction ,compatible and slow closing top revent water hammer,pressureratingupto10.4barandmaximumflowof150GPM,maxwatertemp.upto42degreecentigrade,with24ACsolenoid,currentrating0.41A@60Hz,coilresistance30ohmwithprovisiontoattachPressureRegulatingModule(Dial).Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterialsofapprovedmake,fittings,labour,transportation complete.

7

-

-

... More
Supply,Fixing&CommissoningofPressureRegulatingModule(Dial)toMaintainconstantoutletpressurebetween1.04to6.9bar.Workhastobeexecutedaspertheapproveddrawingsand/orasperthedirectionsoftheengineer-in-charge.Rateinclusiveofallmaterialsofapprovedmake,fittings,labour,transportation complete

7

-

-

... More
Supply,Fixing & Commissoning of direct bury -on wire connector with strain relief ,UL486 D certified ,with waterproof silicon sealant , fits wire from 22 ga to 6 ga as per specifications complete . Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete

21

-

-

... More
Supply,Fixing & Commissoning of moisture sensing device ,to measure soil temp,EC ,Moisture level complete to convert as smart controller,with corrossion resistant sensor and setting thershhold moisture level . Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete

1

-

-

... More
Supply,Fixing & Commissoning of ASTM automatic rain shut off device ,latching hinge with multiple rainfall settings 5mm to 20mm UL CUL listed and CE approved complete . Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.

1

-

-

... More
Supply,Fixing & Commissoning of Pump relay 24 AC PLA relay ,stabiliser 300watts. Work has to be executed as per the approved drawings and/or as per the directions of the engineer-in-charge. Rate inclusive of all materials of approved make,fittings,labour,transportation complete.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.