KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Eprocure
Opening Date13 Sep 2024
Closing Date27 Sep 2024
Tender Amount₹ 4,70,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od234324/2022_2023 : Supply, Installation , testing and commissioning of the following capacity VRF compatible Double Skin Air handling units with AHU Kit with all standard fittings, outlet volume control dampers, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/Sq.ft. of coil surface area for equal distribution, filter section shall comprise of prefilter The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) and bag filter of 99% efficiency down to 3 micron (MERV 13) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement flexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, all housed inside housing of a double skin construction AHU with vibration Supply, Installation , testing and commissioning of the following capacity VRF compatible Air handling units with AHU Kit with all standard fittings, outlet volume control dampers, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/sq.ft. of coil surface area for equal distribution, filter section shall comprise of prefilter The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) aand bag filter of 99% efficiency down to 3 micron (MERV 17-HEPA) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangementflexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, PVC drain pipe connections(upto 5 m) with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc ,power/control cabling from power supply, etc. complete in all respects as per technical specifications.. 25TR (10000 CFM) - 50 mm of WG ESP

1

-

-

... More
od234325/2022_2023 : Supply, Installation , testing and commissioning of the following capacity VRF compatible Double Skin Air handling units with AHU Kit with all standard fittings, outlet volume control dampers, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/Sq.ft. of coil surface area for equal distribution, filter section shall comprise of prefilter The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) and bag filter of 99% efficiency down to 3 micron (MERV 13) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement flexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, all housed inside housing of a double skin construction AHU with vibration Supply, Installation , testing and commissioning of the following capacity VRF compatible Air handling units with AHU Kit with all standard fittings, outlet volume control dampers, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/sq.ft. of coil surface area for equal distribution, filter section shall comprise of prefilter The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) aand bag filter of 99% efficiency down to 3 micron (MERV 17-HEPA) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangementflexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, PVC drain pipe connections(upto 5 m) with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc ,power/control cabling from power supply, etc. complete in all respects as per technical specifications.. 20TR (8000 CFM) - 50 mm of WG ESP

2

-

-

... More
od234345/2022_2023 : Supply, Installation ,testing and commissioning of foolowing minimum capacity Double skin, sheet metal VRF compactable Cieling Suspended Unit inculding AHU kit, all accessories as required as per technical specifications complete with outlet volume control dampers, canvas connections,UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/sq.ft. of coil surface area for equal distribution, The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) aand bag filter of 99% efficiency down to 3 micron (MERV 17) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, power wiring and power/control cabling(indoor to outdoor),digital thermostat with required control wiring, required starter and starter panel , structural supports for fixing IDU, safety devices etc. the following minimum capacity and the cooling coil (min 4 rows), suitable for three phase 440V supply, complete in all respects as per technical specifications.(Minimum External Static Pressur 25 mmwc ) 6 TR-2400 CFM - 25 mm of WG ESP

1

-

-

... More
od234481/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/4") 44.45 mm

10

-

-

... More
od234482/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 5/8") 41.275 mm

48

-

-

... More
od234483/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8") 34.925

48

-

-

... More
od234485/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8") 28.575 mm

10

-

-

... More
od234486/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 7/8") 22.22 mm

10

-

-

... More
od234487/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4") 19.05 mm

126

-

-

... More
od234488/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8") 15.875 mm

12

-

-

... More
od234489/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2") 12.7 mm

10

-

-

... More
od234490/2022_2023 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier & sight glass for liquid line as per specification for each indoor machines & outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable Refnet/ Y joints required for interconnection of piping & required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications. NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/8") 9.525 mm

42

-

-

... More
od234500/2022_2023 : Supply, Installation ,testing and commissioning of PDI Compatible central controller, along with associated accessories for controlling entire VRF system & 25% spare capacity for future provisions with suitable interconnecting control cabling between IDUs, ODUs and central controller ,Power wiring with necessary supports and complete in all respects as per the technical specifications.

1

-

-

... More
od234497/2022_2023 : Supply, installation, testing and commissioning of suitable dia PVC condensate drain pipe of 6kg/sq.cm upto 5m connecting the drain pan of the indoor units to nearest drain point with necessary U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with 7mils factory laminated glass cloth along with required pipe fittings and accessories like Bends, Tees, reducers, clamps, suitably supported etc. complete in all respects as per the technical specifications.

200

-

-

... More
od234502/2022_2023 : Supply, Installation,Testing and Commissioning of minimum 1.5 TR Split air conditioning unit minimum capacity Invertor Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 5 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators for ODU as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports, necessary power/control cabling, suitably supported on trays/ split clamps etc., PVC condensate drain pipe (upto 5 m) 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, , first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete in all respects as per technical specification

5

-

-

... More
od291516/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 100 CFM - 10 mm of WG

2

-

-

... More
od234291/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications.200 CFM -15 mm WG

12

-

-

... More
od273467/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 300 CFM -15 mm WG

2

-

-

... More
od273474/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 400 CFM -10 mm WG br>

1

-

-

... More
od234292/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 500CFM-15mm ESP

2

-

-

... More
od291491/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 600CFM -15mm of WG

2

-

-

... More
od234293/2022_2023 : Supply, Installation testing, and commissioning of Inline Circular/Cabinet fans of the following minimum capacity with suitable blower, Single/3 phase (IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel, structural supports, vibration isolator if required, other accessories etc. complete in all respects as per technical specifications. 900CFM-15mm ESP

1

-

-

... More
od234294/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 1000CFM-15mm ESP

1

-

-

... More
od291466/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 1200CFM -15mm of WG

1

-

-

... More
od291467/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 4500CFM -15mm of WG

1

-

-

... More
od291468/2022_2023 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single/3 phase phase(IE3) direct driven/Belt driven motor of following capacity for exhaust, with applicable Starter /Starter panel , structural supports , vibration isolator if required ,other accessories etc. complete in all respects as per technical specifications. 5000CFM -15mm of WG

1

-

-

... More
AIR DISTRIBUTION

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 0.63 mm sheet duct 24 G

898

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 0.80 mm sheet duct – 22 G

626

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 1.00 mm sheet duct – 20 G

15

-

-

... More
16.12.1.4 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 1.25 mm sheet duct – 18 G

10

-

-

... More
od235171/2022_2023 : Supply, Installation, testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1 with antimicrobial properties. ,having density of 140-180 kg/m3 ,fixing of insulation using OEM recommended fixing details ,supports and adhesive, tapes etc. complete in all respects as per the technical specifications

151

-

-

... More
od235172/2022_2023 : Supplying and fixing of Closed cell nitrile rubber insulation with factory laminated Aluminium FSK facing of 12 micron thickness as mentioned in technical specification ,40-60 kg/m3 density, Butt all joints tightly and seal all breaks and joints by adhering glass cloth tape, fixing of insulation using OEM recommended  fixing  details ,supports and  adhesive, tapes etc. complete in all respects as required by the  technical specifications.The thickness of insulation shall be as per ECBC requirements to meet the temperature conditions of Inside:14 Deg C and Outside 40 Deg C or 19 mm thickness whichever is higher. The item shall be complete in all respects complying to technical specifications. 

1104

-

-

... More
od236440/2022_2023 : Supply & fixing of Acoustic Insulation of AHU Rooms using open cell processed nitrile rubber having a density of 140-180 Kg/m3 and thickness of 25 mm with anti-microbial protection with suitable frame works etc. complete in all respects as required by the technical specifications

572

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

15

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

17

-

-

... More
od234503/2022_2023 : Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers ,bird screen etc. complete in all respects as per the technical specifications.

4

-

-

... More
od234504/2022_2023 : Supply, Installation , testing and commissioning of Aluminium Extruded Fresh air louvers with fresh air damper, bird screen etc complete in all respects as per the technical specifications.

6

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

15

-

-

... More
od236530/2022_2023 : Supply, Installation ,testing & commissioning of Fusible link type Fire damper. Complete in all respects as per the technical specifications.

5

-

-

... More
od235249/2022_2023 : Supply, Installation, testing and commissioning of Under-deck insulation of exposed roof using Class "O" Nitrile rubber insulation of minimum 18mm thickness, anti microbial insulation and stuck to the roof using suitable adhesives, tapes etc. as per the technical specification & manufacturer's recommendation

817

-

-

... More
Air conditioning of Operation Theatres

-

-

-

... More
od235085/2022_2023 : Air Handling Unit: Double skin VRF compatible Air handling units( 50 mm thick panels) with AHU Kit with all standard fittings, outlet volume control dampers, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminum frames. UV emitters shall be minimum 12watt/Sq.ft. of coil surface area for equal distribution, filter section shall comprise of prefilter The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) and bag filter of 99% efficiency down to 3 micron (MERV 13) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, dehumidifiers, humidistat ,all housed inside housing of a double skin construction AHU with vibration isolation arrangement flexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, PVC drain pipe connections(upto 5 m) with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc ,power/control cabling from power supply, etc. complete in all respects as per technical specifications. Capacity: 2000CFM for 5 TR (Minimum External Static Pressure 100 mmwc)

2

-

-

... More
od235089/2022_2023 : Air-cooled VRF condensing unit complete with copper piping between indoor and outdoor units , refrigerant gas, HP and LP cut-off, microprocessor based control panel with suitable control cabling, power wiring(max 3m from isolator), thermostat wiring, etc. Thermostatic expansion valves, thermostats for tripping the compressors after attaining the temperature in conditioned area and with suitable insulation of the suction and liquid line. Air cooled Condenser coil shall be provided with suitable size fan and motor, structural supports for ODU('s) . complete as required by the NABH/ISHRAE specifications. Capacity 8 HP

2

-

-

... More
od235098/2022_2023 : Supply and application of water based washable PU (Polyurethane) Paint on the wall/vitrified wall tiles. Preliminary coating of wall /tile should be provided with one coat of compatible primer followed by 2 coats of PU wall paint. The paint applied should be Non-VOC type. The white cement joints between the tiles on the walls have to be fully covered such that there is a seamless coat of paint on the walls. The paint used should be washable, suitable for hospital application etc. complete as required by the NABH/ASHRAE specifications for an operation theatre application.

343

-

-

... More
od235109/2022_2023 : Suply , installation ,testing and commissioning of Air-Distribution Network for Supply air, Return air, Exhaust Air, Fresh Air made out of 0.8 mm thick Aluminium sheet with suitable gasketing & special sealing , perforated grilles, associated accessories, supports etc. considering OT application and as per relevant SMACNA standards etc. complete in all respects as per technical specifications.

184

-

-

... More
od235121/2022_2023 : Supply , installation ,testing and commissioning of Motorized Volume Control Dampers of 20 gauge SS sheets to be provided with suitable links, levers, actuator and quadrants along with required length of power and control wiring for motorized control of volume of air flow and for proper balancing of the air distributions system etc complete in all respects as per technical specifications

2

-

-

... More
od235134/2022_2023 : Supply, installation ,testing and commissioning of Motorized Fire Damper with suitable links, levers, actuator and quadrants along with required length of power and control wiring for motorized control along with accessories etc complete in all respects as per technical specifications.

2

-

-

... More
od235158/2022_2023 : Supply , installation ,testing and commissioning of Return Air Risers with necessary air distribution networks consisting of aluminium ducts, dampers, collars, grills etc. embedded with modular sandwich Wall panels of 50mm thick EPS Panels with 0.6mm thick coating of SS304 sheet (mat finish) on exposed surface etc. complete as required by the NABH/ASHRAE specifications for an operation theatre. & complete in all respects as per technical specifications

2

-

-

... More
od235165/2022_2023 : Supply, fixing of External Thermal insulation on ducts with 25 mm thick, 40-60 kg/m3 density, regular closed cell nitrile rubber class O insulation with factory laminated Glass cloth with anti-microbial protection as per specification. Quoted price shall be inclusive of adhesive, tapes etc. complete in all respects as per technical specifications.

184

-

-

... More
od235171/2022_2023 : Supply, Installation, testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1 with antimicrobial properties. ,having density of 140-180 kg/m3 ,fixing of insulation using OEM recommended fixing details ,supports and adhesive, tapes etc. complete in all respects as per the technical specifications

34

-

-

... More
od235188/2022_2023 : Supply, fixing of Pre-filters of capacity 2000 cfm for 10μ particles (with one set spare) of MERV 13 as per EN779 Standards.complete as required by the NABH/ASHRAE specifications.

2

-

-

... More
od235190/2022_2023 : Supply, fixing of Pre-fills of capacity 2000 cfm for 5μ particles (with one set spare) of MERV 13 as per EN779 Standards. complete as required by the NABH/ASHRAE specifications.

2

-

-

... More
od235193/2022_2023 : Supply, fixing of HEPA filters with SS plenum : (48SqFt @ 90fpm) Terminal HEPA filters of efficiency 99.97% down to 0.3 microns or higher efficiency shall be provided. Air quality at the supply i.e. at grille level should be Class 1000 (at rest condition). with Gel-seal arrangement to the satisfaction of Engineer-in-Charge, room side replaceable, flange type, specially designed for Operation Theaters with suitable aluminium frame work and HEPA filter Plenum with necessary provisions for Validation . complete as required by the NABH/ASHRAE specifications and as per technical specifications

2

-

-

... More
od235230/2022_2023 : Onsite Validation: HEPA filter Integrity Test, Particle Count Test & Air Velocity etc. complete as required by the NABH/ASHRAE specifications.

2

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od109986/2023_2024 : Supply, Installation, Testing and Commissioning of 150 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

83

-

-

... More
od109987/2023_2024 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

237

-

-

... More
od109989/2023_2024 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

19

-

-

... More
od109991/2023_2024 : Supply, Installation, Testing and Commissioning of 65 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

98

-

-

... More
od109992/2023_2024 : Supply, Installation, Testing and Commissioning of 50 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

70

-

-

... More
od109993/2023_2024 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

229

-

-

... More
od109994/2023_2024 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

30

-

-

... More
od109995/2023_2024 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

579

-

-

... More
od109996/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 150 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

241

-

-

... More
od109997/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 80 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.

7

-

-

... More
od109999/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.

1

-

-

... More
od110001/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 150 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

5

-

-

... More
od110002/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

7

-

-

... More
od110005/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 40 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all Accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

6

-

-

... More
od110008/2023_2024 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification.

14

-

-

... More
od110009/2023_2024 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. Pipe

9

-

-

... More
od110010/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

28

-

-

... More
od110011/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.

14

-

-

... More
od110012/2023_2024 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

14

-

-

... More
od110013/2023_2024 : Supply, installation, testing and commissioning of 4-WAY FIRE BRIGADE inlet connection made of CI Body, 150mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

1

-

-

... More
od110015/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage pendant type sprinkler;1/2" NPT, K -5.0, Chrome Finish with rosetter plate; operating temperature at 68 degC complete as required as per the technical specification.

161

-

-

... More
od110016/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage upright type sprinkler ;1/2" NPT, K -5.0, Chrome Finish; operating temperature at 68 degC complete as required as per the technical specification.

241

-

-

... More
od110017/2023_2024 : Supply, installation, testing and commissioning of 1m unbraided flexible connection to position the sprinkler head in desired location in suspended ceilings. The unit must be complete with stainless steel flexible connection with nipple, reducer, square bar and brackets etc and other accessories as required as per the technical specification.

161

-

-

... More
od110018/2023_2024 : Supply, Installation, Testing and Commissioning of 150mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc. complete as required as per the technical specification.

1

-

-

... More
od110019/2023_2024 : Supply, installation, testing and commissioning of UL listed or FM approved flow switch with SPDT contacts, with fixing accessories suitable for nominal pipe dia meters ranging from 1" to 6". The body of the flow switch shall be water proof with suitable IP class protection. There shall be inbuilt settings to adjust the flow rate and alarm retard time. The flow switch should have minimum withstand pressure of 10Kg/cm2 complete with all accessories as required as per the technical specification.

6

-

-

... More
od110020/2023_2024 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification.

3

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od109962/2023_2024 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

28

-

-

... More
od109969/2023_2024 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

4

-

-

... More
od109973/2023_2024 : Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

1

-

-

... More
od109976/2023_2024 : Supply, installation, testing and commissioning of Modular (Cealing mounted) ABC type extinguisher of 5Kg complete as required with all necessary accessories for successful operation as required as per the technical specification.

10

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
od109965/2023_2024 : Supply, installation, testing and commissioning of Addressable type Multi Detector (smoke & heat sensor) complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, interconnecting to loop cable, complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

279

-

-

... More
od109968/2023_2024 : Supply, installation, testing and commissioning of Addressable type Manual pull station complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

9

-

-

... More
od109972/2023_2024 : Supply, installation, testing and commissioning of addressable type or conventional with addressable module wall sounder cum strobe for both audio and visual indication complete with all fixing accessories, base box etc. under false ceiling, roof, wall, etc, as required as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

9

-

-

... More
od109974/2023_2024 : Supply, installation, testing and commissioning of fault isolator module to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete as required as per technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

17

-

-

... More
od109980/2023_2024 : Supply, installation, testing and commissioning of intelligent addressable Input/ Control module for monitoring and control, as per the technical specification. The product shall be EN/UL/FM/LPCB approved/ listed.

6

-

-

... More
od109981/2023_2024 : Supply, installation, testing and commissioning of addressable relay module to automatically trigger on/off 3rd party devices like fire damper, jet fans, extract air fans etc in case of fire, complete with all accessories as required as per the technical specification. The product shall be UL listed and FM Approved.

1

-

-

... More
od109983/2023_2024 : Supply, installation, testing and commissioning of 24V Power supply unit for hooters with battery backup. The status of the power supply unit must be monitored from the FACP and alarm shall be obtained if the power supply unit fails to operate, complete in all respect with necessary accessories as required as per the technical specification.

1

-

-

... More
od109984/2023_2024 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.

9

-

-

... More
od109985/2023_2024 : Supply, installation, testing and commissioning of public address and talk back system consisting of 10 zone public address cum talk back console with mike and selector, multiple channel talk back facility, power supply, battery charger, battery housing, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier, and suitable capacity battery (min 12V), etc. complete as required for meeting the technical specifications.

1

-

-

... More
od109988/2023_2024 : Supply, installation, testing and commissioning of EN/UL/FM/LPCB approved/ listed, microprocessor based intelligent addressable main fire alarm panel having suitable number of loops to connect all the devices as per BOQ in single panel, central processing unit with the loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, LCD display with touch screen or other keypad and events history log in the non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches whenever any Alarm is triggered. The panel shall have facility to integrate with analog/digital voice evacuation system (PA-talkback system) and shall be complete with all necessary accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as required as per the technical specification and shall have following facilities. a) Programming software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers.

1

-

-

... More
od109990/2023_2024 : Supply and laying of 2x1.5 sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground,on wall surface or recess as required as per the technical specifications.

3479

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

90

-

-

... More
SIGNAGES

-

-

-

... More
od109964/2023_2024 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

15

-

-

... More
od109967/2023_2024 : Supply and installation of photoluminescent glow signage for "FIRE ASSEMBLY POINT" of standard size (500*225 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

2

-

-

... More
od109970/2023_2024 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws &double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

6

-

-

... More
od109977/2023_2024 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

6

-

-

... More
od109979/2023_2024 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.

3

-

-

... More
ELEVATOR SYSTEM

-

-

-

... More
od234825/2022_2023 : Design, fabrication, supply, installation, testing and commissioning of electric traction type with machine room , Stainless steel 26 Pax (1768 Kg) Hospital elevator with car size of 1600 mm (width) x 2400 mm (depth) (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc- except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, over load warning indicator, battery operated alarmbell, LED type emergency light, intercom suitable for hook upto Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, Automatic Rescue Device (ARD) with dry maintenance free sealed batteries, Safe landing device and Battery operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE 3 or better efficiency) of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details:-3 stops & 3 openings and entrance & exit at same side and suitable for travel height of 8.4 mtrs. (Shaft Size 2400mm (width) x 3000mm (depth) ) with door opening of 1200mm (width) and 2000 mm (height) .The equipment should be BMS compatible .All components, fabrication and procedures of elevator system shall confirm to relevant IS standards/ Code and complete in all respects as per technical specifications

2

-

-

... More
STRUCTURED CABLING AND ACTIVE DEVICES

-

-

-

... More
od218749/2022_2023 : Supply, installation, testing and commissioning of U/UTP cable - Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification

3800

-

-

... More
od218756/2022_2023 : Supply, installation, testing and commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with fluke cable analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification

5200

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

500

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1300

-

-

... More
od218762/2022_2023 : Supply and installation of concealed metal backbox with all accessories required at site to complete the work as per technical specification

81

-

-

... More
od218765/2022_2023 : Supply, installation, testing and commissioning of CAT6A Information Outlet, RJ 45 with all accessories required at site to complete the work as per technical specification

57

-

-

... More
od218767/2022_2023 : Supply, installation, testing and commissioning of Cat6 Information Outlet, RJ 45 with all accessories required at site to complete the work as per technical specification

65

-

-

... More
od218768/2022_2023 : Supply, installation, testing and commissioning of Cat6A 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification

3

-

-

... More
od218769/2022_2023 : Supply, installation, testing and commissioning of Cat6 24 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification

4

-

-

... More
od218770/2022_2023 : Supply, installation, testing and commissioning of Single or Dual Shuttered Face Plate with all accessories required at site to complete the work as per technical specification

81

-

-

... More
od218771/2022_2023 : Supply, installation, testing and commissioning of Cat6A Patch Cord - 2m with all accessories required at site to complete the work as per technical specification

67

-

-

... More
od218772/2022_2023 : Supply, installation, testing and commissioning of Cat6 Patch Cord - 2m with all accessories required at site to complete the work as per technical specification

89

-

-

... More
od218773/2022_2023 : Supply, installation, testing and commissioning of Cat6 Patch Cord - 1m with all accessories required at site to complete the work as per technical specification

65

-

-

... More
od218774/2022_2023 : Supply and installation of casing capping with all accessories required at site to complete the work as per technical specification

50

-

-

... More
od218775/2022_2023 : Supply, installation, testing and commissioning of covered GI unperforated cable tray with 200 mm width x 50 mm depth x 1.6 mm thickness (ISI Grade) with thread road, anchor fastener, nut, washer, etc. including all accessories required at site to complete the work as per technical specification

360

-

-

... More
od347351/2022_2023 : Supply, installation, testing and commissioning of single mode 6 core, OS2 Fibre Optic indoor/outdoor Cable through existing cable tray/conduit/HDPE pipe with all accessories required at site complete as per technical specification.

150

-

-

... More
od347454/2022_2023 : Supply, installation, testing and commissioning of 12 port LC single mode rack mount Fiber enclosure LIU, fully Loaded (with LC Pigtails, adapters, Couplers, Splice Tray, Splice holder, etc.) with all accessories required at site complete as per technical specification.

2

-

-

... More
od347499/2022_2023 : Supply, installation, testing and commissioning of Fiber path cord assemblies 3 mtr LC-LC Single Mode Duplex with all accessories required at site complete as per technical specification

2

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia

10

-

-

... More
od347866/2022_2023 : Supply, installation, testing and commissioning of 32mm dia HDPE pipe in surface / ground complete with all accessories including trenching (75 cm deep)and re-filling etc as required at site complete as per technical specification.

100

-

-

... More
od218776/2022_2023 : Supply, installation, testing and commissioning of 24 Port Stackable switch - Layer 2, 24 x 10/100/1000Base-TX ports and 2 x 10G Copper / SFP+ ports with all necessary hardware and accessories required at site to complete the work as per technical specification

3

-

-

... More
od218777/2022_2023 : Supply, installation, testing and commissioning of Core Switch - Layer 3, with min 12 x 10G Copper ports and min 4 x 10G SFP+ ports and all necessary hardware and accessories, as required at site to complete the work as per technical specification

1

-

-

... More
od347799/2022_2023 : Supply, installation, testing and commissioning of 10GBase-LR Transceiver Module - for 10G over single mode fiber with all accessories required at site complete as per technical specification.

2

-

-

... More
od218778/2022_2023 : Supply, installation, testing and commissioning of next generation Firewall having a capacity of handling 150 concurrent users with logs, monitoring, bandwidth management, security subscriptions, including software, licenses and all accessories required at site to complete the work as per technical specification

1

-

-

... More
od218779/2022_2023 : Supply, installation, testing and commissioning of 42U (800mmx1000mm) Network Rack along with all hardware and accessories required at site to complete the work as per technical specification

1

-

-

... More
IP-EPABX

-

-

-

... More
od218755/2022_2023 : Supply, installation, testing and commissioning of license of IP extensions with all accessories required at site to complete the work as per technical specification

56

-

-

... More
od228565/2022_2023 : Supply, installation, testing and commissioning of Standard IP telephone including all accessories as required at site to complete the work as per technical specification

45

-

-

... More
od218761/2022_2023 : Supply, installation, testing and commissioning of 24 Port Stackable PoE+ switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports and 2 x 10G Copper / SFP+ ports with all necessary hardware and accessories required at site to complete the work as per technical specification

3

-

-

... More
LT PANELS BOARDS AND UPS

-

-

-

... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

267.7

-

-

... More
90.14.2.2 : Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

12.45

-

-

... More
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

166.6

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

37.85

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

28278.59

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

7650

-

-

... More
90.14.10.2 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

26

-

-

... More
90.14.10.4 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

-

-

... More
90.14.11.13 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A

38

-

-

... More
90.14.11.15 : MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 315-630 A

1

-

-

... More
od389453/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - BLUE Colour in the existing panel.

5

-

-

... More
od389454/2022_2023 : Supplying and fixing of LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour in the existing panel.

10

-

-

... More
od389458/2022_2023 : Supplying and fixing of 2 A SP MCB (C curve), 10 kA breaking capacity in the existing panel for control devices as required in complete.

8

-

-

... More
od387748/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, up to 160A

36

-

-

... More
od388284/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, 200A-250A

2

-

-

... More
od388463/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 160A, 36 kA (Ics=100%Icu), 3 pole and neutral link current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

3

-

-

... More
od388571/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 125A, 25/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

4

-

-

... More
od389591/2022_2023 : Supply and Fixing of Spreader/terminal adapter kit extended terminal for 3/ 4 pole MCCB/Isolator rating, 500A-630A

1

-

-

... More
od390734/2022_2023 : Supply , conveyance and Fixing voltmeter selector switch in the existing Panel as required

1

-

-

... More
od390749/2022_2023 : Supply and installation of ON OFFindication lamp in existing panel as required

11

-

-

... More
od390752/2022_2023 : Supply , conveyance and Fixing three phase ammeter accuracy class1 in the existing Panel as required

3

-

-

... More
od391112/2022_2023 : Supply , conveyance and Fixing three phase voltmeter accuracy class1 in the existing Panel as required.

1

-

-

... More
2.2.16 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required250 Amp, 36 KA

1

-

-

... More
od398874/2022_2023 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 160A, 25/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

1

-

-

... More
od399127/2022_2023 : Supply and Fixing of Digital Multifunction meter to read: W, Wh, PF or VA, Vah, PF or V AR, V ,A Rh, PF - 3 phase accuracy class 1 LED in the existing Panel as required

10

-

-

... More
od15130/2023_2024 : Supplying and fixing of Resin Cast metering CT 125/5A 10VA accuracy class 1, in existing panel and giving connection complete

2

-

-

... More
od15280/2023_2024 : Supplying and fixing of Resin Cast metering CT 160/5A 15VA accuracy class 1, in existing panel and giving connection complete

2

-

-

... More
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required125 Amp, 36 KA

1

-

-

... More
2.2.7 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required250 Amp, 35 KA,TPMCCB

1

-

-

... More
od41248/2023_2024 : Supply, Installation, Testing & Commissioning of 500A, Four pole, 36 KA, MCCB with microprocessor based release, RS 485 communication facility - 1 No in the exising substation main panel in the outgouing side dummy feeder including all necessary fabrications, instruments, control devices and required control wiring etc. which is similar to other outgoings in complete installation capable for charging the feeder

1

-

-

... More
od60305/2023_2024 : Supplying and fixing of Resin Cast metering CT 100/5A 15VA accuracy class 1, in existing panel and giving connection complete.

6

-

-

... More
od60623/2023_2024 : Supplying and fixing of Resin Cast metering CT 250/5A 10VA accuracy class 1, in existing panel and giving connection complete

6

-

-

... More
od60642/2023_2024 : Supplying and fixing of Resin Cast metering CT 500/5A 15VA accuracy class 1, in existing panel and giving connection complete

3

-

-

... More
od75147/2023_2024 : Supplying and fixing of SPD Class B+C/Type 1+2, Multi stage protection device should be suitable for TNS configuration and should be DIN Rail mounting type. Surge Protection Device Tested as per IEC 61643 Part 11:2016 . Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV . The Surge Protection Devices should have TOV safe fail for 120 Min : 442 V and without Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25 kA/50 kA . Complete with back up fuse required more than 315AgG/gL. Health Status Indication required in all cartridge. Total Response time <25 nano sec. The product should be tested and approved by any one of the following external testing institutes (UL, KEMA, OVE, VDE)

1

-

-

... More
od75418/2023_2024 : Supply, Installation, Testing and Commissioning of 40kVA (N+1 arrangement), three phase input, three phase output, true on-line modular UPS system with 15 minutes back up at unity pf, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc. as required complete having following specification. The UPS system consist of 2 no's of 20 KVA modular units and must have a minimum N+1 rack for mounting UPS modules. Aso required a set of battery bank mounted in battery racks.. Fully digital controlled based on DSP. Power factor corrected from end 0.95 Pure sine wave output. Full time output voltage & frequency regulation. Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch, Auto temperature compensation etc. as required

1

-

-

... More
CABLES AND CABLING

-

-

-

... More
od217508/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 400 Sq.mm Al

1870

-

-

... More
od217569/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 240 Sq mm

30

-

-

... More
od217573/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 185 sqmm Al

20

-

-

... More
od217582/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 35 sqmm Al

515

-

-

... More
od217593/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 16 sqmm Al

1375

-

-

... More
od219290/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 4 sqmm Cu

773

-

-

... More
od219401/2022_2023 : Supply of following 2C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

336

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

336

-

-

... More
7.4.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 185 sq. mm and upto 400 sq. mm

672

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

672

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

545

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

20

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

2554

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

25

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

80

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

220

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

50

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

2

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

8

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

36

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

24

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness

120

-

-

... More
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
4.7.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

8

-

-

... More
4.8.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.8.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.8.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.9.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.9.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
4.9.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

1

-

-

... More
4.10.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.10.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
od234703/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date,2C X 1.5 sq.mm.

202

-

-

... More
od236494/2022_2023 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 2C 1.5 sqmm Cu

12

-

-

... More
od272235/2022_2023 : Supply of 4C 10 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

112

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

4

-

-

... More
od288275/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 120 Sq mm

60

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
od397985/2022_2023 : supply of 3.5C 70 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date.

73

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

6

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

28

-

-

... More
od41647/2023_2024 : Supplying and making end termination with brass double compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C 4 Cu

28

-

-

... More
od41649/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.2C 4 Sq.mm Cu Code

12

-

-

... More
od43869/2023_2024 : Supply and laying of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid / stranded conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 of the following sizes in meduin duty conduit / cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required. and instructed by engineer at site/consultant. 1Cx50 Sq.mm Copper Flexible Cable

100

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

520

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

50

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

511

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

360

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

240

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

300

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

360

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

360

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

116

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

59

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

116

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

59

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

6

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

20

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

95

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

181

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

174

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

114

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

6

-

-

... More
od226903/2022_2023 : Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

22

-

-

... More
od226982/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

67

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

1650

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

4125

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

3600

-

-

... More
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

300

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

385

-

-

... More
MCBs AND DISTRIBUTION BOARDS

-

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

4

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

252

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

21

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

6

-

-

... More
od227898/2022_2023 : Supply and fixing of 40-63A TP MCB, C-Curve following rating, 10 KA, Miniature Circuit Breakers as required.

5

-

-

... More
od227956/2022_2023 : Supply and fixing of following 40-63A FP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required

13

-

-

... More
od232521/2022_2023 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6-32A SP MCB, D-CURVE

168

-

-

... More
od232532/2022_2023 : Supply, Installation, Testing & Commissioning of 25/32A DP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

5

-

-

... More
od232523/2022_2023 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40-63A FP MCB, D-CURVE

6

-

-

... More
od232524/2022_2023 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40-63A TP MCB, D-CURVE

14

-

-

... More
od232533/2022_2023 : Supply, Installation, Testing & Commissioning of 25/32A FP MCB isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete with all accessories

7

-

-

... More
od268828/2022_2023 : Supply installation testing commissioning of 415 V ,160A ,FP, MCCB isolator in CRCA weather proof enclosure including Busbar, RYB indication,spreaders, handle ,door opening interlocking, ample space for cable termination etc as required neccessary to complete installation

1

-

-

... More
od268829/2022_2023 : Supply installation testing commissioning of 415 V ,63A ,FP, MCCB isolator in CRCA weather proof enclosure including Busbar, RYB indication,spreaders, handle ,door opening interlocking, ample space for cable termination etc as required neccessary to complete installation

2

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

12

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

6

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

6

-

-

... More
od36299/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6-32A DP MCB, D-CURVE

6

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

4

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

12

-

-

... More
od36648/2023_2024 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 6-32A FP MCB, C-CURVE

6

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

6

-

-

... More
od43344/2023_2024 : Supply, Installation, Testing & Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

1

-

-

... More
od43648/2023_2024 : Supply installation testing commissioning of 415 V ,125A ,FP, MCCB isolator in CRCA weather proof enclosure including Busbar, RYB indication,spreaders, handle ,door opening interlocking, ample space for cable termination etc as required neccessary to complete installation

1

-

-

... More
od48775/2023_2024 : Supply installation testing commissioning of 415 V ,63A FP, MCB isolator in weather proof enclosure including Busbar, RYB indication, spreaders, handle door opening interlocking, ample space for cable termination etc. as required neccessary to complete installation

2

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

480

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

555

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

2

-

-

... More
od227649/2022_2023 : Supply of 40W (+/-2) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing & High Efficiency Translucence (HET) diffuser. CRI>80, IP65 from front, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Powerfactor>0.95, Surge protection-2 kV, prewired electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

86

-

-

... More
od227666/2022_2023 : Supply of 10 (+/-2) W High efficient LED batten surface/wall mounted, System efficacy of more than 110 lm/W and lumen output of luminaire greater than 1000 lumen, designed extruded channel in thermally conductive material with plastic with HET diffuser. CRI >80, Power factor>0.9, CCT - 6500K, 50000 burning hours as per L70 Criteria.

37

-

-

... More
od228078/2022_2023 : Supply of 400 mm size wall fan having speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor and all accessories as required complete.

5

-

-

... More
od228321/2022_2023 : Supply of 250 mm sweep light duty exhaust fan in metal body with grill/ louvers working on230 V AC supply complete with all accessories as required.

13

-

-

... More
od268368/2022_2023 : Supply of 450mm sweep heavy duty exhaust fan in metal body with grill/ louvers working on 230 V AC supply complete with all accessories as required

2

-

-

... More
od291898/2022_2023 : Supply of 10W +/-2W, High efficient surface mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Powerfactor>0.95, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

21

-

-

... More
od310092/2022_2023 : Supplying and fixing Metal conduit Pipe of more than 8 mm dia, including powder coating/Spray painting similar to the colour shade of the light fixture and all accessories in complete for suspending the light fixture as required.

950

-

-

... More
od310124/2022_2023 : Supplying and fixing extra conduit down rod of G.I. pipe 15 mm dia, heavy gauge including painting etc. for ceiling fans as required

100

-

-

... More
od18498/2023_2024 : Supply of 18W (+/-2), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life THD0.9, Surge protection-2 kV, Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

3

-

-

... More
od37454/2023_2024 : Supply of 12W(+/-2), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Powerfactor>0.95, Surge protection-2 kV,Inbuilt electronic driver, luminaire efficacy > 110 lm/W including all accessories necessary as required to complete installation.

15

-

-

... More
od37586/2023_2024 : Supply of 20W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire br>

207

-

-

... More
od41561/2023_2024 : Supply of 40W Surface/Suspended Mounted LED Batten with System efficacy of more than 110 lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire

67

-

-

... More
od43652/2023_2024 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

60

-

-

... More
od43675/2023_2024 : Supply of Integral, SMD 1x4 LED, IP 20, 36W +/- 4W LED Suspended light fixture with System efficacy not less than 110 lm/W and system lumen output more than 3600lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA housing. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, APFC, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Required nos. of Clamps and other accessories suitable for mounting Conduit pipe/rod to suspend the fixture from the ceiling.

37

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

14

-

-

... More
od75431/2023_2024 : Supply of IP 65 & IK 08 LED surface mounted Bulkhead fixture with System efficacy of more than 105 lm/W. Luminaire shall be made up of Die Cast Aluminium for efficient heat dissipation. Luminaire shall have Polycarbonate diffuser for Uniform illumination and wider light distribution. The LEDs used should be with CCT of 5700 K and CRI > 70, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% including all accessories necessary as required to complete installation.

7

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

1320

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

330

-

-

... More
od228083/2022_2023 : Supply and fixing of laminated shock treatment chart.

2

-

-

... More
od228079/2022_2023 : Supply and fixing of First aid box

1

-

-

... More
od237019/2022_2023 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size including lamination etc. as required complete on wall. br>

1

-

-

... More
od237024/2022_2023 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size br>including lamination etc. as required complete on wall. br>

1

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

550

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

55

-

-

... More
90.16.1.6 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)

220

-

-

... More
od43729/2023_2024 : Earthing with CI earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
od48778/2023_2024 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of size 2m x 1m for 3.3kV grade 2mm thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound

15

-

-

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
od228220/2022_2023 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip

6

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

300

-

-

... More
od272590/2022_2023 : Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing masonry enclosure with heavy duty CI cover plate of 300X300 mm having locking arrangement.

6

-

-

... More
od46788/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

250

-

-

... More
od46792/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for Sheet roof with the required mounting clamps , cross connectors , expansionpiece and other accessories required as per IEC 62305-3

310

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.