KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Civil And Construction
Eprocure
Opening Date12 Aug 2022
Closing Date23 Sep 2022
Tender Amount₹ 25,91,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
LT PANEL BOARDS AND ACCESSORIES

-

-

-

... More
od82680/2022_2023 : Main Switch Board Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type fully type tested 415 V, 50Hz, OEM fabricated panels conforming to IEC 61439 Part 1 , 2 , dust and vermin proof, floor mounted, extendable at both ends, front operated panel board made out of 2 mm or above thick CRCA sheet, fully compartmentalized as per Form 4B Construction, powder coated enclosure after 7 tank process, IP 42 or better ingress protection, complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top and bottom Cable entry .The panel shall be equipped with PLC components for interlock, including all relays, UPS for PLC and all connections and interconnections required for load sharing , interlocking as per PLC Logic indicated in the SLD. EB Incomer 1 , 2:1000A, FP, 50 kA, microprocessor based, electrically draw out type ACB with 3 O/C , 1 E/F release , RS 485 Communication facility ,Lowset earth fault relay (51G),Reverse power relay (32) – 2 Nos. DG Incomer 1 , 2:1000A, FP, 50 kA, microprocessor based, electrically draw out type ACB with 3 O/C , 1 E/F release , RS 485 Communication facility ,Lowset earth fault relay (51G) – 2nos Bus coupler: 2500A, FP, 50 kA, ACB with indication lamps – 1Nos Instruments : Digital power quality meter with Parameters such as THD,kW,kVA,kVAR,kVARh,kWh,Pf,A, V,Hz , RS 485 communication facilities , power quality monitoring , measurement conforming to latest IEC amended up to date etc. with CTs ,control breakers , indication lamp, Ammeter , Voltmeter , selector switch ,etc. as per the SLD , detailed specification – 4 Nos Bus bar: 2500A ,50kA Extendable type Aluminium Bus bar. Surge protection: Type 1 – 2 Nos Outgoing: 800A, TP+NL, 50kA, ⴗP based ACB – 4Nos 630A, TP+NL, 50kA, ⴗP based MCCB – 7Nos 400A, TP+NL, 50kA, ⴗP based MCCB – 5Nos , 400A, TP+NL, 50kA, MCCB Isolator – 1Nos Instruments : Digital multifunctional meter with Parameters such as THD,kW,kVA,kVAR,kVARh,kWh,Pf,A, V,Hz, RS485 communication facilities etc. with CTs, control breakers, indication lamp, Ammeter, Voltmeter,Selector switch, etc. as per the SLD , detailed specification – 17 Nos Note:. Spare cabinets shall be provided for future expansion as indicated in SLD.

1

-

-

... More
od82696/2022_2023 : DG SYNC Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type fully type tested 415 V, 50Hz, OEM fabricated panels conforming to IEC 61439 Part 1 , 2 , dust and vermin proof, floor mounted, extendable at both ends, front operated panel board made out of 2 mm or above thick CRCA sheet, fully compartmentalized as per Form 4B Construction, powder coated enclosure after 7 tank process, IP 42 or better ingress protection, complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top and bottom Cable entry with PLC components for interlock and AMF function ,synchronizing relays, neutral contactors, UPS for PLC and all connections and interconnections required for synchronizing and load sharing as per PLC Logic indicated in SLD. Incomer 1: 1000A, FP, 50 kA, microprocessor based, electrically draw out type ACB with 3 O/C , 1 E/F release , RS 485 Communication facility ,Lowset earth fault relay (51G),Reverse power relay (32) – 1 nos .Incomer 2: 630A, FP, 50 kA, TM based, MCCB with O/C , S/C protection and 600A, FP, Power contactor - 1Nos Incomer 3: 400A, FP, 50 kA, TM based, MCCB with O/C , S/C protection and 400A, FP, Power contactor -1Nos Instruments : Digital multifunctional meter with Parameters such as THD,kW,kVA,kWh,Pf,A, V,Hz , RS 485 communication facilities etc. with CTs ,control breakers , indication lamp, Ammeter , Voltmeter , frequency meter ,selector switch ,etc. as per the SLD , detailed specification – 3 Nos Bus bar: 2500A, 50kA Extendable type Aluminium Bus bar. Surge protection: type 1 – 1 Nos Outgoing: Outgoing 1 , 2 : 1000A, FP, 50 kA, microprocessor based, electrically draw out type ACB with 3 O/C , 1 E/F release , RS 485 Communication facility - 2 Nos .Note : Spare cabinets shall be provided for future expansion as indicated in SLD.

1

-

-

... More
od82868/2022_2023 : LSB Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 400A FP 36kA TM based MCCB Bus bar - 400A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 160A 36kA TP TM Based MCCB - 3Nos. 100A 36kA TP TM Based MCCB - 2Nos.

1

-

-

... More
od82873/2022_2023 : LSSB-1 , LSSB-2 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 160A FP 25kA TM based MCCB Bus bar - 160A 415V, 25 kA best conductivity Al TPN bus bar Instruments -Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 7 Nos.

2

-

-

... More
od82874/2022_2023 : LSSB-3 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 100A FP 25kA TM based MCCB Bus bar - 100A 415V, 25 kA best conductivity Al TPN bus bar Instruments -Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 2 Nos. 25A 25kA TP+NL TM Based MCCB - 5 Nos.

1

-

-

... More
od82883/2022_2023 : PSB Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 630A FP 36kA TM based MCCB Bus bar - 630A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 250A 36kA TP+NL TM Based MCCB - 4 Nos. 125A 36kA TP+NL TM Based MCCB - 1 Nos.

1

-

-

... More
od82899/2022_2023 : PSSB-1 , PSSB-2 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 250A FP 36kA TM based MCCB Bus bar - 250A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 125A 36kA TP+NL TM Based MCCB - 7 Nos.

2

-

-

... More
od82900/2022_2023 : PSSB-3 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 125A FP 36kA TM based MCCB Bus bar - 125A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 36kA TP TM Based MCCB - 7 Nos.

1

-

-

... More
od83020/2022_2023 : 200KVAR APFC PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming fabricated from CPRI/ERDA approved vendors .The enclosure shall be minimum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer: 630 A,36kA FP MCCB with adjustable thermal magnetic release - 1 nos " Instruments :Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, IPFC Relays as per SLD" Busbar 630A TPN busbar chamber with Aluminium busbar " Outgoings: 125A, 36kA, TP MCCB with adjustable thermal magnetic release - 1 nos 63A, 36kA, TP MCCB with adjustable thermal magnetic release - 4 nos 40A, 36kA, TP MCCB with adjustable thermal magnetic release - 1 nos, 25A, 36kA, TP MCCB with adjustable thermal magnetic release - 5 nos 50 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type)- 1 Nos 25 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type)- 4 No 15 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -1 Nos 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2 Nos 5 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) - 3 Nos 50 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1Nos 25 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 4 No 15 kVAr,480 V,50 Hz heavy dutycapacitor(APP-H) with 7 % Seriesreactor -1 Nos 10 kVAr,480 V,50 Hz heavy dutycapacitor(APP-H) with 7 % Seriesreactor -2 Nos 5 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 3 Nos Control wiring required for no load compensation capacitor.

2

-

-

... More
od83021/2022_2023 : UPS-SSB-OT-TF Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 160A FP 25kA TM based MCCB -2 Nos Bus bar - 160A 415V, 25kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 14 Nos.

1

-

-

... More
od83022/2022_2023 : UPS-SSB-OT-GF Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 125A FP 25kA TM based MCCB with mechanical interlock -2 Nos Bus bar - 125A 415V, 25kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 9 Nos.

1

-

-

... More
od83023/2022_2023 : UPS-SSB-GF-3,UPS-SSB-1F-3,UPS-SSB-2F-3,UPS-SSB-3F-3, Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 63A FP 25kA TM based MCCB Bus bar - 63A 415V, 25kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 40A 25kA TP+NL TM Based MCCB - 2 Nos. 25A 25kA TP+NL TM Based MCCB - 2 Nos.

4

-

-

... More
od83024/2022_2023 : UPS SSB-LGF-2,UPS-SSB-GF-2,UPS-SSB-1F-2,UPS-SSB-2F-2,UPS-SSB-3F-2 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 100A FP 25kA TM based MCCB Bus bar - 100A 415V, 25kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 2 Nos. 40A 25kA TP+NL TM Based MCCB - 2 Nos. 25A 25kA TP+NL TM Based MCCB - 2 Nos.

5

-

-

... More
od83025/2022_2023 : UPS SSB-LGF-1,UPS-SSB-GF-1,UPS-SSB-1F-1,UPS-SSB-2F-1,UPS-SSB-3F-1 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 100A FP 25kA TM based MCCB Bus bar - 100A 415V, 25kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 2 Nos. 40A 25kA TP+NL TM Based MCCB - 2 Nos. 25A 25kA TP+NL TM Based MCCB - 2 Nos.

5

-

-

... More
od83026/2022_2023 : UPS SSB-3 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 100A FP 36kA TM based MCCB Bus bar - 100A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 8 Nos.

1

-

-

... More
od83027/2022_2023 : UPS SSB-1 , UPS SSB -2 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 200A FP 36kA TM based MCCB Bus bar - 200A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 100A 25kA TP+NL TM Based MCCB - 8 Nos.

2

-

-

... More
od83028/2022_2023 : UPS PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 400A FP 36kA TM based MCCB Bus bar - 400A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 200A 36kA TP+NL TM Based MCCB - 3 Nos. 160A 36kA TP+NL TM Based MCCB - 2 Nos. 125A 36kA TP+NL TM Based MCCB - 3 Nos. 100A 36kA TP+NL TM Based MCCB - 1 Nos.

1

-

-

... More
od83029/2022_2023 : LIFT PANEL - 4 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 125A FP 25kA TM based MCCB Bus bar - 125A 415V, 25 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 80A 25kA TP+NL TM Based MCCB - 2 Nos. 63A 25kA TP+NL TM Based MCCB - 2 Nos.

1

-

-

... More
od83030/2022_2023 : LIFT PANEL - 1,2 , 3 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 160A FP 25kA TM based MCCB Bus bar - 160A 415V, 25 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 80A 25kA TP+NL TM Based MCCB - 2 Nos. 63A 25kA TP+NL TM Based MCCB - 5 Nos.

3

-

-

... More
od83031/2022_2023 : CSSD PANEL , LAUNDARY PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 200A FP 36kA TM based MCCB Bus bar - 200A 415V, 36 kA best conductivity Al TPN bus bar Instruments - 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 125A 36kA TP+NL TM Based MCCB - 2 Nos. 63A 36kA TP+NL TM Based MCCB - 6 Nos.

1

-

-

... More
od83032/2022_2023 : MAIN LIFT PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 400A FP 36kA TM based MCCB Bus bar - 400A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 160A 36kA TP+NL TM Based MCCB - 4 Nos. 125A 36kA TP+NL TM Based MCCB - 2 Nos.

1

-

-

... More
od83033/2022_2023 : COMMON PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 800A FP 50kA Microprocessor based ACB Bus bar - 800A 415V, 50 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 400A 36kA TP+NL TM Based MCCB - 1 Nos. 250A 36kA TP+NL TM Based MCCB - 7 Nos. 160A 36kA TP+NL TM Based MCCB - 2 Nos.

1

-

-

... More
od83034/2022_2023 : MEDICAL EQUIPMENT PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 630A FP 36kA TM based MCCB Bus bar - 630A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 250A 36kA TP+NL TM Based MCCB - 5 Nos. 200A 36kA TP+NL TM Based MCCB - 3 Nos. 100A 36kA TP+NL TM Based MCCB - 2 Nos.

1

-

-

... More
od83035/2022_2023 : SSB-P-3F-1 , SSB-P-3F-2 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 125A FP 25kA TM based MCCB Bus bar - 125A 415V, 25 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches, Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 4 Nos. 40A 25kA TP+NL TM Based MCCB - 2 Nos.

2

-

-

... More
od83036/2022_2023 : SSB-P-GF-1,SSB-P-GF-2,SSB-P-1F-1,SSB-P-1F-2,SSB-P-2F-1 , SSB-P-2F-2 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 125A FP 25kA TM based MCCB Bus bar - 125A 415V, 25 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 2 Nos. 40A 25kA TP+NL TM Based MCCB - 2 Nos.

6

-

-

... More
od83842/2022_2023 : SSB-P-LGF Supply, Installation, Testing , Commissioning of LT Switch Boardcubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification. The Panel shall be of Form 4A Construction suitable for top cable entry Incomer - 125A FP 25kA TM based MCCB Bus bar - 125A 415V, 25 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 63A 25kA TP+NL TM Based MCCB - 2 Nos. 40A 25kA TP+NL TM Based MCCB - 4 Nos.

1

-

-

... More
od83916/2022_2023 : HVAC-ODU-SSB-GF Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minimum 2 mm thick CRCA sheet for load bearing members , minimum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 200A FP 36kA TM based MCCB Bus bar - 200A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 100A 25kA TP+NL TM Based MCCB - 2 Nos. 63A 25kA TP+NL TM Based MCCB - 4 Nos.

1

-

-

... More
od83917/2022_2023 : HVAC PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 800A FP 50kA Microprocessor based ACB Bus bar - 800 A 415V, 50 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 630A 36kA TP+NL TM Based MCCB - 2 Nos. 400A 36kA TP+NL TM Based MCCB - 1 Nos. 250A 36kA TP+NL TM Based MCCB - 2 Nos. 200A 36kA TP+NL TM Based MCCB - 1 Nos. 125A 36kA TP+NL TM Based MCCB - 2 Nos.

1

-

-

... More
od83918/2022_2023 : HVAC-ODU-SSB-LGF Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minimum 2 mm thick CRCA sheet for load bearing members , minimum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 250A FP 36kA TM based MCCB Bus bar - 250A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 100A 25kA TP+NL TM Based MCCB - 4 Nos. 63A 25kA TP+NL TM Based MCCB - 2 Nos.

1

-

-

... More
od83919/2022_2023 : HVAC-ODU-SSB-SF Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 125A FP 36kA TM based MCCB Bus bar - 125A 415V, 36 kA best conductivity Al TPN bus bar Instruments -Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 100A 25kA TP+NL TM Based MCCB - 3 Nos. 63A 25kA TP+NL TM Based MCCB - 1 Nos.

1

-

-

... More
od83920/2022_2023 : HVAC-ODU-SSB-TF Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 630A FP 36kA TM based MCCB Bus bar - 630A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches, Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 125A 25kA TP+NL TM Based MCCB - 1 Nos. 100A 25kA TP+NL TM Based MCCB - 3 Nos. 63A 25kA TP+NL TM Based MCCB - 8 Nos.

1

-

-

... More
od83991/2022_2023 : AC-IDU-SSB-2 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 250A FP 36kA TM based MCCB Bus bar - 250A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 125A 25kA TP+NL TM Based MCCB - 1 Nos. 63A 25kA TP+NL TM Based MCCB - 5 Nos.

1

-

-

... More
od83992/2022_2023 : AC-IDU-SSB-1 Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 125A FP 36kA TM based MCCB Bus bar - 125A 415V, 36 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 125A 25kA TP+NL TM Based MCCB - 1 Nos. 63A 25kA TP+NL TM Based MCCB - 8 Nos.

1

-

-

... More
od84554/2022_2023 : PUMP PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for top entry cables.Incomer - 160A FP 36kA TM based MCCB -1 Nos Bus bar - 160A 415V, 36kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 40A TP+NL MPCB with star delta starter suitable for 15Hp pump -4 Nos 40A TP+NL MPCB - 1 Nos 25A TP+NL MPCB with star delta starter suitable for 7.5 Hp pump -2 Nos 16A TP+NL MPCB with star delta starter suitable for pump less than 5Hp -8 Nos 16A TP+NL MPCB -1 Nos 25A 16kA TP+NL TM Based MCCB - 1 Nos. Busbar 160A TPN busbar chamber with Aluminium busbar

1

-

-

... More
od84926/2022_2023 : SERVICE PANEL Supply, Installation, Testing , Commissioning of fully type tested 415V , 50Hz, LT switch board conforming to IEC 61439 Part 1&2 fabricated from CPRI/ERDA approved vendors .The enclosure shall be minumum 2 mm thick CRCA sheet for load bearing members , minumum 1.5 mm thick for non load bearing members , free standing with floor mounting base(if floor mounted )or Wall mounting type with suitable mounting brackets with all accessories as required to complete installation.The IP rating shall be 42 or better and form of construction shall be form 4 . The short circuit rating shall be suitable to with stand the short circuit rating of incomer breaker (the design calculation for the mechanical strength of busbar supports , spacing between supports ,temperature rise etc shall be furnished ).The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire .Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top entry cables. Incomer - 100A FP 25kA TM based MCCB Bus bar - 100A 415V, 25 kA best conductivity Al TPN bus bar Instruments - Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, as per SLD Outgoings 40 A 25kA TP+NL TM Based MCCB - 6 Nos.

1

-

-

... More
od85030/2022_2023 : Supply, Installation, Testing and commissioning of Outdoor Lighting Panel (ODP) cubicle type, made out of thermoplastic UV resistant enclosure, totally enclosed, IP65, free standing, floor mounting, dust and vermin proof, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessary internal wiring , suitable spreader etc. certification for similar panels (required for short circuit rating, temperature rise and IP classification) shall be submitted .Panel shall be with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification." " INCOMER : 40 A, FP, 25kA, MCCB with adjustable thermal magnetic release with OL , SC protection - 1 No BUSBAR : 40A TPN busbars of high conductivity electrolytic quality copper alloy INSTRUMENTS : 4A, C curve SP MCB - 3 Nos, RYB indication lamp, LED type - 1 Set, timer clock with 40A FP contactor having an astronomical 365 day timer clock with Sunrise/Sunset tracking- 1 Nos OUTGOINGS : , 16 A C Curve FP 100mA , RCCB+MCB-4 Nos

1

-

-

... More
DG SET AND ACCESSORIES

-

-

-

... More
od85428/2022_2023 : Supply, Installation, Testing and Commissioning of 250 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks,CTs and transducers for all metering and protection and suitable MCCB , Contactor with O/L,O/V,U/V,Negative sequence, Low set Earth Fault,& REF differential relay with fuel shutoff,Overspeed protection etc , including ant vibration mountings, thermal insulated exhaust silencer and exhaust pipe (pipe measured separately) conforming to latest environment protection regulations for emission and noise levels complete with , water / coolant cooled, (radiator type) four stroke, electric start , 250 kVA prime rating, brushless, selfexcited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5%Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to IS/IEC 60034-1. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards. Fuel tank for 8 hours suitable continuous operation,fuel piping from fuel tank to Engine, Residential silencer, LV chamber suitable for termination of cable etc as required and as per technical specifications.The work should be as per Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
od85431/2022_2023 : Supply, Installation, Testing and Commissioning of 380 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks,CTs and transducers for all metering and protection and suitable MCCB , Contactor with O/L,O/V,U/V,Negative sequence, Low set Earth Fault,& REF differential relay with fuel shutoff,Overspeed protection etc , including ant vibration mountings, thermal insulated exhaust silencer and exhaust pipe (pipe measured separately) conforming to latest environment protection regulations for emission and noise levels complete with , water / coolant cooled, (radiator type) four stroke, electric start , 380 kVA prime rating, brushless, selfexcited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5%Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to IS/IEC 60034-1. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards. Fuel tank for 8 hours suitable continuous operation,fuel piping from fuel tank to Engine, Residential silencer, LV chamber suitable for termination of cable etc as required and as per technical specifications.The work should be as per Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
od85433/2022_2023 : Supply, Installation, Testing and Commissioning of 625 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks,CTs and transducers for all metering and protection and suitable ACB with O/L,O/V,U/V,Negative sequence, Low set Earth Fault,& REF differential relay with fuel shutoff,Overspeed protection etc , including ant vibration mountings, thermal insulated exhaust silencer and exhaust pipe (pipe measured separately) conforming to latest environment protection regulations for emission and noise levels complete with , water / coolant cooled, (radiator type) four stroke, electric start , 625 kVA prime rating, brushless, selfexcited, self-regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5%Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to IS/IEC 60034-1. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards. Fuel tank for 8 hours suitable continuous operation,fuel piping from fuel tank to Engine, Residential silencer, LV chamber suitable for termination of cable etc as required and as per technical specifications.The work should be as per Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
od85486/2022_2023 : Supply, Fabrication and Installation of exhaust stack for DG with mild steel exhaust pipe (minimum 150mm dia) complete with fittings, cutting, bending, welding and applying a priming coat of approved steel primer and finishing with Epoxy paint (two or more coats) at all locations prepared and applied as required , approved by the Engineer Incharge.

75

-

-

... More
od85487/2022_2023 : Supply, Fabrication and Installation of exhaust stack for DG with mild steel exhaust pipe (minimum 150mm dia) complete with fittings, cutting, bending, welding, 75 mm thick 96 kg/ cu.m density, mineral wool or equal insulation covered with 24 SWG. Aluminium sheet cladding etc. complete as required , approved by the Engineer Incharge.

15

-

-

... More
od85488/2022_2023 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and finishing with Epoxy paint (two or more coats) at all locations prepared and applied using structural steel etc. as required, all complete

1500

-

-

... More
UPS AND ACCESSORIES

-

-

-

... More
od115258/2022_2023 : Supply Installation Testing , Commissioning of not less than 200KW Modular Rack with 25KW X 6 No modules in N+1 configuration ,suitable for future expansion upto 200kW with Input Voltage 415V, output voltage 415V, Input power factor 0.99 Thdi <3%,including suitable size isolation transformer, Efficiency at Double conversion mode 96%, IP20, with 15 mins battery back up and with all necessary Battery Breaker, Rack, Interlinks, control Cables, cables between UPS , Battery .Batteries shall be as per technical specifcation attached.

1

-

-

... More
CABLES AND ACCESSORIES

-

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

105

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

15

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

10

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

5

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
10.6.4 : Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
od45229/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.3C 6 sqmm Cu

216

-

-

... More
od45230/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.3C 4 sqmm Cu

200

-

-

... More
od45231/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3C 10 sqmm Al

504

-

-

... More
od45232/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 16 sqmm Al

3208

-

-

... More
od45233/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 35 sqmm Al

1570

-

-

... More
od45235/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 70 sqmm Al

924

-

-

... More
od45236/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 120 sqmm Al

1812

-

-

... More
od45237/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 185 sqmm Al

1709

-

-

... More
od45238/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 240 sqmm Al

1674

-

-

... More
od45266/2022_2023 : Supply of 4C 10 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

1962

-

-

... More
od45311/2022_2023 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx400sq.mm Al Cable

3846

-

-

... More
od45351/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 50 Sq.mm Al

36

-

-

... More
od45356/2022_2023 : Supply of 4C 25 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

282

-

-

... More
od45563/2022_2023 : Supply of 12C x 2.5 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor Control cable conforming to IS 7098 (Part 1) amended upto date.

480

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

104

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

22

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

30

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

44

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

98

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

106

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

8

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

76

-

-

... More
od45631/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12C 2.5 sqmmCu

18

-

-

... More
od46598/2022_2023 : Supply and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc as required. and instructed by engineer in charge 1C x 120 sq.mm CU Flexible

60

-

-

... More
od46660/2022_2023 : Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Single core Copper conductor cable of 1.1 KV grade as required. 1C x 120 sq.mm Cu cable

10

-

-

... More
od46692/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 4 sq.mm

10

-

-

... More
od46709/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 10 sq.mm

28

-

-

... More
od46710/2022_2023 : Supplying and making end termination with brass compression gland and Cu lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required. 3C X 6 sq.mm

12

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

300

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

150

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

245

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

405

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

232

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

30

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

106

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

106

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

7170

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

824

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

3130

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

4909

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

20

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

20

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

20

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

20

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

20

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

20

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

20

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

20

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

230

-

-

... More
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness Details of cost for 30 metres

230

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

405

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

1090

-

-

... More
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness

435

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

24

-

-

... More
od85550/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 95 Sq.mm AL

85

-

-

... More
od113451/2022_2023 : Supply of following 3C X 300 sq.mm sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade(earthed) conforming to IS 7098 amended upto date

135

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

32400

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

56810

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

45810

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

44064

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

70330

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

1500

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

232

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

2125

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

402

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

158

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

316

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

158

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

316

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

79

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

4031

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

3955

-

-

... More
od42699/2022_2023 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

605

-

-

... More
od42787/2022_2023 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

330

-

-

... More
od85238/2022_2023 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

2515

-

-

... More
od85271/2022_2023 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.

2573

-

-

... More
od85279/2022_2023 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

18

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

474

-

-

... More
MCB AND MCB DISTRIBUTION BOARDS

-

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

7

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

41

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

31

-

-

... More
90.11.1.13 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)

17

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

13

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

5

-

-

... More
90.11.1.21 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

18

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

18

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

24

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

18

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

48

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1438

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

104

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

323

-

-

... More
2.24.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB

7

-

-

... More
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

41

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

31

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

19

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

20

-

-

... More
od57536/2022_2023 : Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release in existing cubicle panel board or VDB including drilling holes in cubicle panel, making connections, etc. including all accessories as required.16A - 100A 16kA FP TM, MCCB

15

-

-

... More
od57928/2022_2023 : Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release in existing cubicle panel board or VDB including drilling holes in cubicle panel, making connections, etc. including all accessories as required.125A 16kA FP TM, MCCB

1

-

-

... More
od58192/2022_2023 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “D” curve,miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Triple pole and neutral

24

-

-

... More
od58193/2022_2023 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current 100milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63amps

17

-

-

... More
od58194/2022_2023 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current 100milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

31

-

-

... More
od58303/2022_2023 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, " D" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

24

-

-

... More
od58304/2022_2023 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, " C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral

24

-

-

... More
od58340/2022_2023 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, " C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

20

-

-

... More
od58368/2022_2023 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “D” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole

988

-

-

... More
od58446/2022_2023 : Supply, Installation, Testing , Commissioning of 63 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete

17

-

-

... More
od58447/2022_2023 : Supply, Installation, Testing , Commissioning of 100 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete

12

-

-

... More
od58448/2022_2023 : Supply, Installation, Testing , Commissioning of 125 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete

1

-

-

... More
od58528/2022_2023 : Supplying and fixing Cable End Boxes (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.(For VDB with MCCB as incomer)

15

-

-

... More
od58539/2022_2023 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 12 way, Double door TPN MCBDB

17

-

-

... More
od58541/2022_2023 : Supply installation testing commissioning of 415 V ,400A ,FP, MCCB isolator in CRCA sheet steel enclosure including Busbar, RYB indication,spreaders, handle ,door opening interlocking, ample space for cable termination etc as required neccessary to complete installation

2

-

-

... More
od58542/2022_2023 : Supply, Installation, Testing , Commissioning of 32 A FP MCB isolator in CRCA sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete

20

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

20

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od46957/2022_2023 : Supply of 40W (+/-10%),4ft, High efficient LED batten surface/wall mounted with Aluminium alloy housing and polycarbonate diffuser.IP20, CRI 80, Temperature range-0 to 45 DegC, Power factor 0.9,THD<10%, Surge protection 2 kV, 50000 or above burning hours as per L70 Criteria, Inbuilt electronic driver, luminaire efficacy not less than 120 lm/W as per LM79 including all accessories necessary as required to complete installation

1372

-

-

... More
od46958/2022_2023 : Supply of 18W(+/-10%) ,4ft, High efficient LED batten surface/wall mounted with Aluminium alloy housing and polycarbonate diffuser.IP20, CRI 80, Temperature range-0 to 45 DegC, Power factor 0.9, THD<10%, Surge protection 2kV, 50000 or above burning hours as per L70 Criteria, Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79 including all accessories necessary as required to complete installation

135

-

-

... More
od46962/2022_2023 : Supply of 10W(+/-10%),2ft, High efficient LED batten surface/wall mounted with Aluminium alloy housing and polycarbonate diffuser.IP20, CRI 80, Temperature range-0 to 45 DegC, Power factor 0.9, THD<10%, Surge protection 2kV, 50000 or above burning hours as per L70 Criteria, Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79, including all accessories necessary as required to complete installation

36

-

-

... More
od47954/2022_2023 : Supply of 9W(+/-10%), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Power factor 0.9, Surge protection-2 kV,Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79, including all accessories necessary as required to complete installation

578

-

-

... More
od48200/2022_2023 : Supply of 18W(+/-10%), High efficient surface mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs @ L70 life.THD<10%, Powerfactor 0.9, Surge protection-2 kV,Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79, including all accessories necessary as required to complete installation

168

-

-

... More
od48201/2022_2023 : Supply of 50W , High efficient LED Flood light luminaire with aluminium die cast housing , High transmittivity polycarbonate diffuser. CRI 80, IP66, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life.THD<10%, Powerfactor 0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy 100 lm/W including all accessories necessary as required to complete installation

7

-

-

... More
od48202/2022_2023 : Supply of 36W (+/-10%) , High efficient recess mounted 2 x 2 LED luminaire with steel housing , High transmittivity polycarbonate diffuser. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs as per L70 criteria .THD<10%, Power factor 0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy not less than 110 lm/W as per LM79 , including all accessories necessary as required to complete installation

1005

-

-

... More
od48203/2022_2023 : Supply of 40W (+/-10%) , High efficient recess mounted 2 x 2 clean room LED luminaire with CRCA housing , High Efficiency Translucence (HET) diffuser. CRI 80, IP65 from front , Ambient temp-0 to 45DegC, 50,000 hrs as per L70 criteria .THD<10%, Power factor 0.9, Surge protection-2 kV,prewired electronic driver, luminaire efficacy not less than 110 lm/W including all accessories necessary as required to complete installation

354

-

-

... More
od48204/2022_2023 : Supply of 18W(+/-10%), High efficient recess mounted LED round downlighter with white powder coated, Aluminium die cast aluminium housing. High transmittivity polycarbonate diffuser provides soft light. CRI 80, IP20, Ambient temp-0 to 45DegC, 50,000 hrs as per L70 criteria.THD<10%, Powerfactor 0.9, Surge protection-2 kV,Inbuilt electronic driver, luminaire efficacy not less than 110 lm/W as per LM79 including all accessories necessary as required to complete installation

237

-

-

... More
od81971/2022_2023 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote (with remote holder) or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

1098

-

-

... More
od85163/2022_2023 : Supply of 450mm sweep heavy duty exhaust fan in die cast aluminium with metal grill/ louvers working on 230 V AC supply complete with all accessories as required.

43

-

-

... More
od85164/2022_2023 : Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal body with grill/ louvers working on 230 V AC supply complete with all accessories as required.

48

-

-

... More
od85218/2022_2023 : Supply of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.

30

-

-

... More
EARTHING, LIGHTNING PROTECTION AND SAFETY EQUIPMENT

-

-

-

... More
od55467/2022_2023 : Supplying and laying 32 mm X 6 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt , spring washer spaced at 50mm)

209

-

-

... More
od55633/2022_2023 : Supplying and laying 50 mm X 10 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt , spring washer spaced at 50mm)

517

-

-

... More
od55717/2022_2023 : Providing and fixing 32 mm X 6 mm copper strip on surface ,recess or in tray for connections etc.as required.

2475

-

-

... More
od55759/2022_2023 : Providing and fixing 50 mm X 10 mm copper strip on surface ,recess or in tray for connections etc.as required.

101

-

-

... More
od55820/2022_2023 : Providing and fixing 25 mm X 5 mm copper strip on surface , recess or in tray for connections etc.as required.

844

-

-

... More
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

2750

-

-

... More
od55875/2022_2023 : Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories,and providing masonry enclosure with CI/MS cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set

31

-

-

... More
od55916/2022_2023 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

1750

-

-

... More
od55941/2022_2023 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for Sheet roof with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

420

-

-

... More
od55943/2022_2023 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

966

-

-

... More
od55947/2022_2023 : Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32 mm x 6mm and 8mm dia solid round aluminium conductor conforming to the requirements according to (IS/IEC 62305) with all accessories complete as required

46

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

400

-

-

... More
od55973/2022_2023 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone , anchors etc . as required per IEC 62305-3 4Mtr Airterminal

3

-

-

... More
od55974/2022_2023 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone ,anchors etc . as required per IEC 62305-3 2Mtr Airterminal

3

-

-

... More
od55976/2022_2023 : Providing and laying earth connection with 4.00 mm dia copper wire including all accessories, connections ,excavation and re-filling as required.

750

-

-

... More
od56349/2022_2023 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

75

-

-

... More
od56350/2022_2023 : Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound

5

-

-

... More
od56351/2022_2023 : Supply and fixing of First aid box

3

-

-

... More
od56352/2022_2023 : Supplying of Rubber hand gloves suitable for 11 KV.

2

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

10

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

75

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
90.15.3.5 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters

26

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

52

-

-

... More
90.15.3.6 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters

13

-

-

... More
SOLAR

-

-

-

... More
od84556/2022_2023 : Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box , Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections , Interconnections by supplying , fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying , fixing of necessary channel/conduit lugs and other accessories etc. as required. (Measurement unit shall be KWp)

150

-

-

... More
HVAC EQUIPMENTS

-

-

-

... More
od238812/2021_2022 : Supply, Installation, Testing, Commissioning of 18 HP (minimum capacity Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

2

-

-

... More
od238813/2021_2022 : Supply, Installation, Testing, Commissioning of 28 HP (minimum capacity ) Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

1

-

-

... More
od238814/2021_2022 : Supply, Installation, Testing, Commissioning of 30 HP (minimum capacity ) Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

2

-

-

... More
od238815/2021_2022 : Supply, Installation, Testing, Commissioning of 32 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

3

-

-

... More
od88620/2022_2023 : Supply, Installation ,testing and commissioning of 34 HP Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

1

-

-

... More
od238816/2021_2022 : Supply, Installation, Testing, Commissioning of 40 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

2

-

-

... More
od238817/2021_2022 : Supply, Installation, Testing, Commissioning of 50 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

1

-

-

... More
od238818/2021_2022 : Supply, Installation, Testing, Commissioning of 56 HP (minimum capacity )Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel , associated accessories, suitable interconnecting control cabling between IDUs,ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units).

1

-

-

... More
od238819/2021_2022 : Supply, Installation , testing and commissioning of the following capacity VRF compatible Air handling units with AHU Kit with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with cordless remotes, power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, PVC drain pipe connections(upto 5 m) with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc., filter section shall be 99% efficiency down to 3 micron MERV 13 filters complying to ASHRAE 52.2 required starter panel and control panel , structural supports , safety devices .power/control cabling from power supply, etc. complete in all respects as per technical specifications.. 25TR (10000 CFM) - 50 mm of WG ESP

3

-

-

... More
od238820/2021_2022 : Supply, Installation ,testing and commissioning of minimum 11TR(4400 CFM) capacity Double skin, sheet metal VRF compactable AIR-HANDLING UNIT inculding AHU kit, all accessories as required as per technical specifications complete with outlet volume control dampers, canvas connections, filter section shall be 99% efficiency down to 3 micron MERV 13 filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, power wiring and power/control cabling(indoor to outdoor),digital thermostat with required control wiring, required starter panel and control panel , structural supports for fixing IDU, safety devices etc. the following minimum capacity and the cooling coil (min 4 rows), suitable for three phase 440V supply, complete in all respects as per technical specifications.(Minimum External Static Pressur 50 mmwc )

4

-

-

... More
od238821/2021_2022 : Supply, Installation , testing and commissioning of the 8 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.

3

-

-

... More
od238822/2021_2022 : Supply, Installation , testing and commissioning of the 6 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.

1

-

-

... More
od238823/2021_2022 : Supply, Installation , testing and commissioning of the 5 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.

9

-

-

... More
od238824/2021_2022 : Supply, Installation , testing and commissioning of the 4 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.

5

-

-

... More
od238825/2021_2022 : Supply, Installation , testing and commissioning of the 3 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.

7

-

-

... More
od238826/2021_2022 : Supply, Installation , testing and commissioning of the 2 TR minimum capacity ceiling suspended indoor ductable units for VRF system with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan,complete with cordless remotes, suitable capacity drive motor, electrical controller, temperature controller with digital display, complete with necessary vibration isolators, Suitable dia PVC drain pipe of 6Kg/Sq cm (upto 5m) connections with 9mm thick round nitrile rubber insulation finished with 7 mils factory laminated fibre glass cloth, including U-trap along with necessary elbows, fittings etc., All asscociated electrical works including power , control cabling etc. complete in all respects as per the technical specifications.

2

-

-

... More
od238828/2021_2022 : Supply, Installation ,testing and commissioning of 2 TR minimum capacity VRF compatible indoor evaporative units Cassette type with cordless remote, of following minimum capacities suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, electrical cabling from power plug, structural supports, vibrations isolators etc. complete in all respects as per the technical specifications.

11

-

-

... More
od238829/2021_2022 : Supply, Installation ,testing and commissioning of 1.5 TR minimum capacity VRF compatible indoor evaporative units Cassette type with cordless remote, of following minimum capacities suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, electrical cabling from power plug, structural supports, vibrations isolators etc. complete in all respects as per the technical specifications.

10

-

-

... More
od238830/2021_2022 : Supply, Installation ,testing and commissioning of 1 TR minimum capacity VRF compatible indoor evaporative units Cassette type with cordless remote, of following minimum capacities suitable for operation single phase, 230 V, 50Hz supply, including fixing of room unit, with high lift drain pump, electrical cabling from power plug, structural supports, vibrations isolators etc. complete in all respects as per the technical specifications.

2

-

-

... More
od238831/2021_2022 : Supply, Installation ,testing , commissioning of 2 TR minimum capacity VRF compatible Hi wall air conditioning unit of following capacity complete with suitable capacity drive motor, all associated electrical works including power/control cabling (indoor to outdoor), cordless remote,high lift condensate drain pump suitable for single phase 230 V supply etc. complete in all respects as per the technical specifications.

2

-

-

... More
od238832/2021_2022 : Supply, Installation ,testing , commissioning of 1.5 TR minimum capacity VRF compatible Hi wall air conditioning unit of following capacity complete with suitable capacity drive motor, all associated electrical works including power/control cabling (indoor to outdoor), cordless remote,high lift condensate drain pump suitable for single phase 230 V supply etc. complete in all respects as per the technical specifications..

4

-

-

... More
od238833/2021_2022 : Supply, Installation ,testing , commissioning of 1 TR minimum capacity VRF compatible Hi wall air conditioning unit of following capacity complete with suitable capacity drive motor, all associated electrical works including power/control cabling (indoor to outdoor), cordless remote,high lift condensate drain pump suitable for single phase 230 V supply etc. complete in all respects as per the technical specifications.

4

-

-

... More
od238835/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/4" ) 44.4mm

20

-

-

... More
od238837/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 5/8" ) 41.3mm

78

-

-

... More
od238839/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/2" ) 38.1mm

20

-

-

... More
od238841/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8" ) 34.9mm

180

-

-

... More
od238842/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/4" ) 31.8mm

20

-

-

... More
od238843/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8" ) 28.6mm

276

-

-

... More
od238844/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 " )25.4mm

20

-

-

... More
od238846/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 7/8" ) 22.2mm

54

-

-

... More
od238849/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4" )19.05mm

240

-

-

... More
od238850/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8" )15.88mm

396

-

-

... More
od238852/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2" )12.7mm

324

-

-

... More
od238853/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/8" ) 9.52mm

372

-

-

... More
od238854/2021_2022 : Supply, Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber class 'O' insulation of suitable thick round closed cell elastomeric insulation with minimum R value of 0.7 for pipe size greater than 40mm and 0.4 for less than 40 mm, finished with 7mils factory laminated fibre glass cloth and insulation shall have antimicrobial properties. Refrigerant piping shall have suction filters for gas line, filter drier , sight glass for liquid line as per specification for each indoor machines , outdoor units including chasing, drilling, concealing and making good the same on walls etc of following specifications as per site conditions. Suitable refnets/ Y joints required for interconnection of piping , required pipe fittings and accessories like Bends, Tees, reducers,supports, clamps, etc shall be considered as part of refrigerant piping .Complete in all respects as per technical specifications.NOTE: The contractor shall ensure that all refrigerant pipe sizes required as per the design of the equipment shall be considered in the line items underneath, even if the refrigerant pipe size is not mentioned in following line items. Both refrigerant suction and liquid line shall be insulated. Soft Copper Pipe 18Guage with 19mm thick Insulation ( 1/4" ) 6.35mm

114

-

-

... More
od238856/2021_2022 : Supply, installation testing and commissioning of 1.5 TR minimum capacity Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 3 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation as per specification interconnecting indoor , outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports finished with 7 mils factory laminated treated fibre glass cloth, necessary power/control cabling, suitably supported on trays/ split clamps etc., first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete in all respects as per the technical specifications.

2

-

-

... More
od238857/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1700 CFM -20 mm of WG ESP

2

-

-

... More
od238858/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1400 CFM -20 mm of WG ESP

11

-

-

... More
od238859/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1200 CFM -20 mm of WG ESP

1

-

-

... More
od238860/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1100 CFM -20 mm of WG ESP

1

-

-

... More
od238861/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 1000 CFM -20 mm of WG ESP

2

-

-

... More
od238862/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 900 CFM -20 mm of WG ESP

4

-

-

... More
od238863/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 800 CFM -20 mm of WG ESP

4

-

-

... More
od238864/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 700 CFM -20 mm of WG ESP

4

-

-

... More
od238865/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 600 CFM -20 mm of WG ESP

2

-

-

... More
od239037/2021_2022 : Supply, Installation testing and commissioning of Inline Circular/Cabinet fans of following minimum capacity with suitable blower, Single phase direct driven motor of following capacity for exhaust application with applicable Starter /Starter panel required power cabling from single point power supply,required structural supports ,vibration isolator ,all other accessories etc.complete in all respects as per the technical specifications: 500 CFM -20 mm of WG ESP

7

-

-

... More
od238866/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 400 CFM -20 mm of WG ESP

12

-

-

... More
od238867/2021_2022 : Supply, Installation, testing and commissioning of Circular/Cabinet inline fans following capacities with suitable blower, Single phase direct driven motor for exhaust application with starter/Starter panel ,required power cabling from single point power supply, required structural supports,Vibration isolator , all other accessories required etc. complete in all respects as per technical specifications 200 CFM -15 mm of WG ESP

1

-

-

... More
od238868/2021_2022 : Supply, installation, testing and commissioning of PVC drain pipe of 6Kg/Sq.cm of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with insulated with 9 mm thick closed cell elastomeric class 0 insulation with 7 mils factory laminated glass cloth as per specification required pipe fittings and accessories like bends, tees, reducers, supports, clamps, suitably supported on trays, clamps etc. complete in all respects as per the technical specifications.

600

-

-

... More
AIR DISTRIBUTION SYSTEM

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 0.63 mm sheet duct 24 G

3409

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 0.80 mm sheet duct – 22 G

1290

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 1.00 mm sheet duct – 20 G

44

-

-

... More
16.12.1.4 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 1.20 mm sheet duct – 18 G

22

-

-

... More
od238870/2021_2022 : Air-Distribution Network for Supply air, Return air,Exhaust Air,Fresh Air made out of suitable gauge Aluminum sheet with suitable gasketing , special sealing , perforated grilles, associated accessories, supports etc. for MRI/CT room application and as per relevant SMACNA standards etc complete in all respects as per the technical specifications.

100

-

-

... More
16.23.1 : Supplying and fixing of 19mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required with R value less than 0.6. complete in all respects as per the technical specifications.

3297

-

-

... More
16.21.1 : Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3, with 25 mm X 25 mm Gl section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 16 br brAcoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3

328

-

-

... More
od354475/2021_2022 : DSR - 16.22 Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. 50 mm thick resin bonded glass wool having density of 32 kg/m³

858

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

5

-

-

... More
od238899/2021_2022 : DSR 16.16 Supplying , fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

5

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

32

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

53

-

-

... More
od353834/2021_2022 : Supply, Installation , testing and commissioning of Aluminium extruded exhaust air louvers with damper, bird screen etc. complete in all respects as per technical specifications.

15

-

-

... More
od238901/2021_2022 : Supply, Installation , testing and commissioning of Aluminium extruded fresh air louvers with fresh air damper,bird screen etc. complete in all respects as required by the technical specifications..

5

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

48

-

-

... More
od238920/2021_2022 : Supply, Installation ,testing , commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks , complete in all respects as per the technical specifications.

21

-

-

... More
od238918/2021_2022 : Supply, Installation ,testing and commissioning of Under-deck insulation of exposed roof using Class " O" Nitrile rubber insulation of 19mm thickness, anti microbial insulation and stuck to the roof using suitable adhesives, tapes etc. complete in all respects as per technical specifications , manufacturer's recommendation.

2336

-

-

... More
od238919/2021_2022 : Air curtain Supply, installation, testing and commissioning of air curtains of width 1.0 m (15 amps female socket will be provided by Client outside the compartment. Supplier shall draw connection from the socket to air curtain using mail socket and cable) The system shall include all accessories including motors, blowers, door opening sensors, asscoiated electrical and control cabling etc. complete in all respects as per technical specifications.

10

-

-

... More
ELEVATOR SYSTEM

-

-

-

... More
od239085/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 20 Pax (1360 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST ) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. complete as per technical specification. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm fluted SS sheet flooring as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 2400mm (width) x 3100mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) ,door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

2

-

-

... More
od239364/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 15Pax (1020 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides,2 mm fluted SS sheet flooring as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 2200mm (width) x 3000mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

2

-

-

... More
od239428/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 26 Pax (1768 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. Except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor(IE3or better efficiency of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm Fluted SS sheet flooring as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 2650mm (width) x 3400mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

4

-

-

... More
od239488/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 20 Pax Hospital elevator (1360 Kg) (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. Having automatic centre/side opening SS door, stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm fluted SS sheet flooring as applicable in accordance of following details:-4 stops , 4 openings and entrance , exit at same side and suitable for travel height of 12.6 mtrs. (Shaft Size 2400mm (width) x 3000mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

4

-

-

... More
od239506/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction type with machine roomless type , Stainless steel 20 Pax (1360 Kg) Hospital elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. Except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers' EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The traction motor(IE3 efficieny grade or better ) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way , the Drives shall meet the requirements of IEEE 519/2014. Having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2 mm fluted SS sheet flooring as applicable in accordance of following details:-4 stops , 4 openings and entrance , exit at same side and suitable for travel height of 12.6 mtrs. (Shaft Size 2400mm (width) x 3100mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) , door opening of 1200mm (width) and 2100 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

2

-

-

... More
od239514/2021_2022 : Design, fabrication, supply, Installation ,Testing and Commissioning of electric traction type with machine roomless type , Stainless steel 250Kg capacity Dumb Waiter elevator, (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of minimum 0.3 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, LED type emergency light, reverse phase relay on controller, LCD/LED car positions and direction indication in car and landings. at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor(IE3or better efficiency) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having vertical bi-parting opening SS door with handles, stainless steel car enclosure as applicable in accordance of following details:-5 stops , 5 openings and entrance , exit at same side and suitable for travel height of 16.8 mtrs. (Shaft Size 1600mm (width) x 1200mm (depth) ) with door opening of 1000mm. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

1

-

-

... More
od239521/2021_2022 : Design, fabrication, supply, Installation ,Testing and Commissioning of electric traction type with machine roomless type , Stainless steel 250Kg capacity Dumb Waiter elevator (including freight , landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of minimum 0.3 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, LED type emergency light, reverse phase relay on controller, LCD/LED car positions and direction indication in car and landings. at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor(IE3or better efficiency) of machine roomless elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having vertical bi-parting opening SS door with handles, stainless steel car enclosure as applicable in accordance of following details:-2 stops , 2 openings and entrance , exit at same side and suitable for travel height of 4.2 mtrs. (Shaft Size 1700mm (width) x 1200mm (depth) ) with door opening of 1000 mm. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

1

-

-

... More
od242825/2021_2022 : Statutory fees associated with elevator installation , licensing (lift inspection , Lift insurance)

16

-

-

... More
STRUCTURED CABLING COMPONENTS

-

-

-

... More
od175316/2021_2022 : Supply, installation, testing and commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site to complete the work as per technical specification

37800

-

-

... More
od177695/2021_2022 : Supply, installation, testing and commissioning of U/UTP cable - Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site to complete the work as per technical specification

42300

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

13400

-

-

... More
od175324/2021_2022 : Supply and installation of concealed metal back box with all accessories required at site to complete the work as per technical specification

603

-

-

... More
od175328/2021_2022 : Supply and installation of PVC backbox with all accessories as required at site to complete the work as per technical specification

50

-

-

... More
od175332/2021_2022 : Supply, installation, testing and commissioning of Category 6 information Outlet, RJ 45 with all accessories required at site including termination to complete the work as per technical specification

431

-

-

... More
od177707/2021_2022 : Supply, installation, testing and commissioning of Category 6A Information Outlet, RJ 45 with all accessories required at site including termination to complete the work as per technical specification

603

-

-

... More
od175335/2021_2022 : Supply, installation, testing and commissioning of Category 6 24 port patch panel, fully loaded with I/Os, including termination as required at site complete the work as per technical specification

41

-

-

... More
od177723/2021_2022 : Supply, installation, testing and commissioning of Category 6A 24 port patch panel, fully loaded with I/Os, including termination as required at site to complete the work as per technical specification

32

-

-

... More
od185459/2021_2022 : Supply, installation, testing and commissioning of 50 port Category 3 voice patch panel, fully loaded, including termination with all accessories required at site to complete the work as per technical specification

15

-

-

... More
od175336/2021_2022 : Supply and installation of single or dual shuttered faceplate with all accessories required at site to complete the work as per technical specification

653

-

-

... More
od175337/2021_2022 : Supply, installation, testing and commissioning of Category 6 - 2m patch cord with end termination and all accessories required at site to complete the work as per technical specification

543

-

-

... More
od177852/2021_2022 : Supply, installation, testing and commissioning of Category 6A - 2m patch cord with end termination and all accessories required at site to complete the work as per technical specification

613

-

-

... More
od178259/2021_2022 : Supply, installation, testing and commissioning of Category 6A - 1m patch cord with end termination and all accessories required at site to complete the work as per technical specification.

53

-

-

... More
od180546/2021_2022 : Supply, Installation, Testing and Commissioning of 50 pair telephone riser cable, including termination, with all accessories required at site complete as per technical specifications

2100

-

-

... More
od175339/2021_2022 : Supply, installation, testing and commissioning of 6 core, single mode, OS2, fibre optic indoor/outdoor cable through existing cable trays or pipes including termination with all accessories required at site to complete the work as per technical specification

5810

-

-

... More
od175340/2021_2022 : Supply, installation, testing and commissioning of 24 port LC single mode rack mount fiber enclosure LIU, fully loaded (with LC pigtails / adapters / couplers / splice tray / splice holder, etc) with all accessories required at site to complete the work as per technical specification

26

-

-

... More
od175341/2021_2022 : Supply, installation, testing and commissioning of fiber path cord - 3 meter, LC-LC, single mode, duplex with all accessories required at site to complete the work as per technical specification

86

-

-

... More
od175342/2021_2022 : Supply and installation of PVC casing capping with all accessories required at site to complete the work as per technical specification

200

-

-

... More
od175343/2021_2022 : Supply and installation of covered unperforated hot dipped galvanised iron cable tray of size - 300 mm width x 50 mm depth x 1.6 mm thickness, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts and nuts and all accessories like bends, tees, reducers, etc required at site to complete the work as per technical specification

2600

-

-

... More
od175344/2021_2022 : Supply and installation of 32mm HDPE Pipe, ISI marked, along with all accessories like socket, bend, couplers, complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required at site to complete the work as per technical specification

200

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

50

-

-

... More
od185460/2021_2022 : Supply, installation, testing and commissioning of 600 pair MDF with krone modules, jumper wires, including termination and all other accessories required at site to complete the work as per technical specification

1

-

-

... More
od178863/2021_2022 : Supply, installation, testing and commissioning of 27U floor mount network rack, size - 600 x 800mm, along with all necessary hardware and accessories required at site to complete the work as per technical specification

14

-

-

... More
od175346/2021_2022 : Supply, installation, testing and commissioning of 42U floor mount network rack, size - 800 x 1000mm, along with all necessary hardware and accessories required at site to complete the work as per technical specification

3

-

-

... More
IP-EPABX

-

-

-

... More
od175309/2021_2022 : Supply, installation, testing and commissioning of IP based EPABX system having capacity of 600 analog extensions and 50 IP extensions, 2 PRI, 60 channel SIP trunk, scalable up to 1500 extensions, including a desktop based operator console, with all hardware, software, licenses, cabling and other accessories required at site to complete the work as per technical specification

1

-

-

... More
IP SURVEILLANCE

-

-

-

... More
od175314/2021_2022 : Supply, installation, testing and commissioning of 2MP varifocal motorised IP camera, PoE, IP66 rated with all accessories required at site to complete the work as per technical specification

102

-

-

... More
od175321/2021_2022 : Supply, installation, testing and commissioning of 128 channel Network Video Recorder, RAID 5, SAS/Enterprise HDDs for 30 days archiving, including a desktop with all hardware, software, cabling and other accessories as required at site to complete the work as per technical specification.

1

-

-

... More
od185461/2021_2022 : Supply, installation, testing and commissioning of 55" commercial display, 24/7 with HDMI and USB ports with all accessories required at site to complete the work as per technical specification

2

-

-

... More
ATTENDANCE SYSTEM

-

-

-

... More
od175313/2021_2022 : Supply, installation, testing and commissioning of Attendance machine, fingerprint and proximity card based, PoE, with all hardware, software, cabling and other accessories required at site to complete the work as per technical specification

4

-

-

... More
PUBLIC ADDRESS AND EVACUATION SYSTEM

-

-

-

... More
od175312/2021_2022 : Supply, installation, testing and commissioning of 2 core 1.5 sq.mm speaker cable, FRLS, with all accessories required at site to complete the work as per technical specification

12500

-

-

... More
od175318/2021_2022 : Supply, installation, testing and commissioning of 6W metal Ceiling Speaker with all accessories required at site to complete the work as per technical specification

530

-

-

... More
od175322/2021_2022 : Supply, installation, testing and commissioning of 6W Wall mount Speaker with all accessories required at site to complete the work as per technical specification

424

-

-

... More
od175327/2021_2022 : Supply, installation, testing and commissioning of 480W Power Amplifier with all accessories required at site to complete the work as per technical specification

18

-

-

... More
od175331/2021_2022 : Supply, installation, testing and commissioning of Public Address and Evacuation system Controller capable of managing up to 18 individual zones with BGM, announcement, automatic emergency message facility, integration with Fire alarm system and all accessories as required at site to complete the work as per technical specification

1

-

-

... More
od175333/2021_2022 : Supply, installation, testing and commissioning of Paging Microphone with multi tone chime and multi channel zone selector for 18 zones with all accessories required at site to complete the work as per technical specification

6

-

-

... More
RODENT REPELLENT SYSTEM

-

-

-

... More
od175311/2021_2022 : Supply, installation, testing and commissioning of Rodent repellent system including main console, transducers, cabling and all accessories required at site to complete the work as per technical specification

1

-

-

... More
ACTIVE DEVICES

-

-

-

... More
od175315/2021_2022 : Supply, installation, testing and commissioning of 24 port stackable Switch - Layer 2, 24 x 10/100/1000Base-TX ports with 2 x 10G SFP+ ports including all necessary hardware, software and accessories required at site to complete the work as per technical specification

31

-

-

... More
od175323/2021_2022 : Supply, installation, testing and commissioning of 24 port PoE+ stackable Switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports with 2 x 10G SFP+ ports including all necessary hardware, software and accessories as required at site to complete the work as per technical specification

14

-

-

... More
od175325/2021_2022 : Supply, installation, testing and commissioning of 24 port Core switch - Layer 3, with minimum 22 x 10G SFP+ ports and 2 x 10G combo copper/SFP+ ports including all necessary hardware, software and accessories required at site to complete the work as per technical specification

2

-

-

... More
od175329/2021_2022 : Supply, installation, testing and commissioning of 24 port PoE switch - Layer 2, 24 x 10/100/1000Base-TX PoE ports with 2 x 1G SFP ports including all necessary hardware, software and accessories as required at site to complete the work as per technical specification

14

-

-

... More
od175330/2021_2022 : Supply, installation, testing and commissioning of 24 port Fiber Switch with minimum 20 x 1G SFP ports and 2 x 1G Copper ports including all necessary hardware, software and accessories as required at site complete as per technical specification

1

-

-

... More
od179555/2021_2022 : Supply, installation, testing and commissioning of 10G SFP+ Transceiver module, LC type, for single mode fiber including all accessories required at site to complete the work as per technical specification

58

-

-

... More
od179556/2021_2022 : Supply, installation, testing and commissioning of 1G SFP Transceiver module, LC type, for single mode fiber including all accessories required at site to complete the work as per technical specification

28

-

-

... More
od175334/2021_2022 : Supply, installation, testing and commissioning of next generation Firewall for 1500 users with logs, monitoring, bandwidth management, etc. including hardware, software, licenses, security subscriptions, cabling and other accessories required at site to complete the work as per technical specification.

1

-

-

... More
WI-FI ACCESS POINT

-

-

-

... More
od175310/2021_2022 : Supply, installation, testing and commissioning of Wireless Access Point, Wi-Fi 6, dual-band, 2x2 MIMO, PoE, including mounting brackets and all accessories required at site to complete the work as per technical specification

53

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.